BUILDING DATA YEAR EDITION OF CODES: LEAD DESIGN PROFESSIONAL: Alteration Upfit Renovation (Existing Bldg.) New Construction E-MAIL PHONE # NAME FIRM Mechanical Electrical Architectural DESIGNER Phone # County City State Private City/County Code Enforcement Jurisdiction: Owned By: Owner or Authorized Agent: Proposed Use: Address: Name of Project: Reconstruction --- . D.C. District of Columbia-Department of General Services Elementary School 2701 Naylor Road, SE Washington DC 20020 Stanton Elementary School 2013 District of Columbia Construction Code Supplement 2013 District of Columbia Green Construction Guide 2009 ICC/ANSI A117.1 Accessibility Code 2012 International Building Code 2012 International Existing Building Code 2012 International Energy Conservation Code See Consultanting Engineering Sheets for Additional Applicable Codes . [email protected] LITTLE Beth Buffington 571-257-2905 --- * CONSTRUCTION TYPE PRESUMED BASED ON EXISTING CONDITIONS OBSERVED IN FIELD & DOCUMENTS PROVIDED BY THE DC DEPARTMENT OF GENERAL SERVICES. ** 508.3.1 ACCESSORY OCCUPANCY EXCEPTION 2. ACCESSORY ASSEMBLY SPACES IN GROUP E OCCUPANCIES ARE NOT REGULATED AS SEPARATE OCCUPANCIES. *** THE EXISTING ANNEX BUILDING WILL BE DEMOLISHED IN THE NEXT ACADEMIC YEAR. IT IS BEING USED AS A "SWING SPACE" UNTIL THE ADDITION IS BUILT. BUILDING CODE ANALYSIS IBC 2012 BLDG, USE GROUP CLASSIFICATION (S) EXISTING IBC 2012 BLDG AND NFPA 101 2009, 2012 E NFPA 101 OCCUPANCY CLASSIFICATION(S) EDUCATION SEPARATED MIXED USE per IBC/NFPA (Y/N) NO** NO** CONSTRUCTION TYPE per IBC 2012 II-B* NUMBER OF STORIES above grade 3 HIGH RISE (Y/N) N FIRE ALARM SYSTEM (Y/N) Y FULLY SPRINKLED & MONITORED (Y/N) MAIN EXISTING BUILDING N PROPOSED 3 N Y Y E II-B* BUILDING AREA per IBC 503 * (SF): TOTAL 3rd Floor 2nd Floor NEW + EXISTING EXISTING FLOOR 12,709 SF 13,479 SF 62,254 SF 1st Floor 19,249 SF Basement 16,817 SF *IBC 503 A building area is the area measured within the perimeter formed by the inside surface of the exterior walls. The steam tunnels were included in this area. 1. Table 503 Allowable Building Heights & Areas. For Occupancy Group E and Construction Type IIB-2 stories, 55 feet max. height, and 14,500 sf per floor. 2. 504.2 Automatic sprinkler increase increased by 20 feet and 1 story. 75 feet & 3 stories. 3. 506.3 Automatic sprinkler increase by an additional 200% for buildings with more than 1 story above the grade plane. EDUCATION MAX NUMBER OF STORIES 3 - WITH SPRINKLER SYSTEM ACTUAL # OF STORIES 3 MAX HEIGHT 75 FT MAXIMUM ACTUAL HEIGHT 50 FT MAX SF PER STORY 43,500 (PER IBC 506 EQUATION 506.1) Equation 506.1 A allowable = {A tabular + (A tablular x Area Increase per Frontage) + (Area tabular x Area Increase due to Sprinker)} A allowable = {14,500 + 0 + 14,500 x 2} A allowable = 43,500 sf [email protected] Engenium Group Brandon Harwick 202-787-1098 [email protected] Engenium Group Brandon Harwick 202-787-1098 FULLY SPRINKLED & MONITORED (Y/N) EXISTING ANNEX BUILDING Y Y *** 18,621 SF 19,325 SF 83,703 SF 31,974 SF 13,783 SF 00 ELEVATION MARKER 2 A201 DETAIL MARKER A301 2 SECTION MARKER 1 A301 00 ELEVATION DATUM POINT NORTH ARROW COLUMN GRID AND GRID BUBBLES NORTH TRUE NORTH Level Name 0'-0" X X X X AXXX WALL TYPE MATERIALS INDICATOR INTERIOR ELEVATION CEILING HEIGHT MARKER DOOR MARKER WINDOW MARKER ROOM NUMBER ROOM NAME 1t 101 Room name 101 1i 1 View Name 1/8" = 1'-0" A101 VIEW TITLE ON SHEET CENTER LINE Room name 101 150 SF ROOM NUMBER ROOM NAME ROOM AREA 2 3 4 B C E 1 A D Exist. Telcm E005 Exist. Elect. E004 STORAGE 120A Exist. Toilet E002A Exist. Toilet E001A Exist. Toilet E007A Exist. Toilet E003A Exist. Office E008 713 SF CLASSROOM 110 529 SF CLASSROOM 111 PANTRY 102A WELCOME 101 108 SF ADMIN. 102 102 SF WORK RM. 103 STO. 120B 256 SF ENTRY VESTIBULE 100 959 SF ATELIER 104 865 SF CLASSROOM 113 619 SF CLASSROOM 112 SCALE: 3/32" = 1'-0" A B C D EXIT ACCESS TRAVEL DISTANCE: A TO B = 114'-0" B TO C = 35'-0" C TO D = 61'-0" 5/8" G.W.B. @ BOTH SIDES SCHEDULED BASE SCHEDULED FLOOR FINISH METAL RUNNER (BOTTOM TRACK) 3 5/8" METAL STUDS @ 24" O.C. METAL SLOTTED DEFLECTION TRACK (TYP. ALL TYPES) UNDERSIDE OF SLAB SCHEDULED CEILING 4 7/8" PLAN HEAD BASE SEALANT @ BETWEEN G.W.B. FINISH & CONCRETE FLOOR, BOTH SIDES PARTITION TYPE B40A 0' - 6" (MIN. EA. SIDE) 1' - 0" SOUND ATTENUATION BLANKET; LAID ABOVE WALL 5/8" G.W.B. @ BOTH SIDES SCHEDULED BASE SCHEDULED FLOOR FINISH METAL RUNNER (BOTTOM TRACK) 3 5/8" METAL STUDS @ 24" O.C. METAL SLOTTED DEFLECTION TRACK (TYP. ALL TYPES) SCHEDULED CEILING PLAN HEAD BASE PARTITION TYPE 4 7/8" G.W.B. CASING BEAD @ BOTH SIDES ACOUSTICAL JOINT SEALANT @ BETWEEN G.W.B. FINISH & CONCRETE FLOOR, BOTH SIDES SOUND ATTENUATION BLANKET G2 T/ WALL 7'-0" AFF 5/8" G.W.B. SCHEDULED BASE SCHEDULED FLOOR FINISH METAL RUNNER (BOTTOM TRACK) 2 1/2" METAL STUDS @ 24" O.C. PLAN HEAD BASE PARTITION TYPE UNDERSIDE OF STRUCTURE 6" SCHEDULED CEILING METAL SLOTTED DEFLECTION TRACK (TYP. ALL TYPES) F30 Index of Drawings Building Code Summary Symbols Legend w w w . l i t t l e o n l i n e . c o m PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE Beth Buffington, AIA JC Sanchez RS, AZ T: 703.908.4501 F: 703.908.4502 FRIENDSHIP PUBLIC CHARTER SCHOOL Little 2015 c 4245 North Fairfax Drive, Suite 650 Arlington, VA 22203 This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 213.4789.00 06/19/2015 A0001 BUILDING CODE SUMMARY, INDEX OF DRAWINGS, & GENERAL INFORMATION ARMSTRONG REGGIO EMILIA RENOVATION 1400 1ST FIRST STREET, NW WASHINGTON, D.C. 20001 PERMIT SUBMISSION A0001 BUILDING CODE SUMMARY, INDEX OF DRAWINGS, & GENERAL INFORMATION A0101 FIRST FLOOR PLAN - EXISTING & DEMOLITION A0102 FIRST FLOOR RCP - EXISTING & DEMOLITION A0112 FIRST FLOOR PLAN AND RCP - PROPOSED & SELECT INTERIOR SECTIONS & ELEVATIONS E0001 ELECTRICAL COVER SHEET E0101 ELECTRICAL LIGHTING PLAN | Architectural | General | Mechanical | Electrical Life Safety Plan Door Schedule Door Number Type Door Fire Rating Hardware Frame Width Height Thickness Material Finish Under Cut Type Material Finish Jamb Head 120A 4 2' - 6" 7' - 0" 0' - 2" 104A 1 3' - 0" 7' - 0" 0' - 2" 100A 12 5' - 8" 7' - 0" 0' - 2" 120B 12 5' - 8" 7' - 0" 0' - 2" E005A 1 3' - 0" 7' - 0" 0' - 2" E004A 1 3' - 0" 7' - 0" 0' - 2" Window Schedule Type Mark R.O. Type Manufacturer Model Material Finish Head Jamb Sill Glazing Head Height Width Height Thickness Type W1 3' - 0" 2' - 0" Fixed 5' - 0" Door Schedule Window Schedule Partition Types | Fire Alarm FA0001 FIRE ALARM COVER SHEET FA0101 FIRE ALARM FLOOR PLAN NO. REASON DATE ARCHITECTS M&E ENGINEERING 4245 North Fairfax Drive Suite 650 Arlington, VA 22203 703.908.4501 Contact: Beth Buffington, AIA LITTLE 1001 Connecticut Avenue, NW Suite 1128 Washington, DC 20036 202.505.3646 Contact: Brandon Harwick, PE Engenium Group M0001 MECHANICAL COVER SHEET AND SPECS M0101 MECHANICAL NEW WORK PLAN