BUFFER TANK FOR SOLAR AND HEATINGPSM / PSF / PSR / PSRR PZ / PZR / PZRR
The AE buffer tanks are suitable for all hot water central heating systems, whether solid fuel, oil fired boilers, heat pumps, solar panels, gas or electric water heaters.You can add more buffer tanks in parallel to increase capacity (see technical data and accessories), according to your re-quirements. Furthermore, the buffer tanks can also be used for cold-water storage cooling or heat recovery processes can be used (operating system pressure at 4 bar) in industrial facilities (suitable Armaflex insulation to be used but must be installed on site).Austria Email offers advice on supplementary equipment needed, such as the installation of heat exchangers or electric heating option depending on the power required (for more information see accessories brochure).
Energy-saving ECO SKIN 2.0 thermal insulation is used for our complete buffer tank range.
* On the PSM 1000 buffer storage, as compared to the soft foam insulation
BY A PERFECT FIT
NEU ECO SKIN 2.0
BUFFER TANK FOR SOLAR AND HEATINGECO DESIGN - LABELING
Unsere bewährte Pufferspeicherlinie PS wird durch eine hochwertige Alternative ergänzt.Durch die PZ/PZR/PZRR mit einer Schichteinrichtung im Heizungsrücklauf und einer Schichttrennplatte. Hochgezogene Anschluss-rohre im Vorlauf zur besseren Ausnutzung des Pufferinhaltes und Fühlerkanäle zur flexiblen Positionierung der Temperaturfühler run-den das innovative Konzept ab.
PZR PZRRPZ
500 l
800 l
1000 l
1500 l
Topplemm H
Hwith
insulta-ion øD
with insulta-
tion A B C E F(PZ / PZR /
PZRR)(PZ / PZR /
PZRR)(PZ / PZR /
PZRR)(PZ / PZR /
PZRR)(PZ / PZR /
PZRR)(PZ / PZR / PZRR)
1670
1750
2090
2270
1640
1700
2050
2150
1725
1785
2135
2235
650
790
790
1000
850
990
990
1200
220
260
310
380
320
365
415
480
620
630
745
825
1010
1030
1250
1350
1390
1430
1710
1760
-/715/715
-/845/845
-/1030/1030
-/1175/1175
-/-/1040
-/-/1070
-/-/1160
-/-/1265
-/1,9/1,9
-/2,4/2,4
-/3,0/3,0
-/3,6/3,6
-/-/1,2
-/-/1,6
-/-/2,4
-/-/2,4
-/12,3/12,3
-/15,6/15,6
-/19,2/19,2
-/23,5/23,5
-/-/7,9
-/-/10,6
-/-/15,6
-/-/15,6
Type
Dimensions in mm
øDG J below belowtop top
Register area m2
Register contentsl
PZ
PZR
PZRR
•
•
•
•
•
•
•
•
•
•
•
•
Type 500 800 1000 1500
SPECIFICATIONS
n Nominal content of PSF / PSM / PSR / PSRR of 500 to 5000 litres; nominal content PZ / PZR / PZRR from 500 to 1500 litres
n High quality steel St 37-2
n ECO SKIN 2.0 - fleece insulation 100 mm (up to 5000 l)
n Large pipe register with types PSR / PSRR and PZR/PZRR
n 240 mm with flange for types PSF for the instal-lation of a finned tube heat exchanger or heating installation
n Operating pressure 3 bar, Test pressure 4,5 bar in the buffer storage tank
n Operating pressure max. 10 bar, test pressure 15 bar in the tube register with types PSR / PSRR and PZR / PZRR
n 9 Connection thread 6/4‘‘ (female)
n Rule 4 female thread 1/2‘‘ ID (inner thread) with types PSF / PSR and PSM / PSRR
n 2 sensors channels for variable positioning of the sensor in types PZ / PZR and PZRR
nOperating temperature 95 ° C, 110 ° C in the hea-ting coil
n Powder coated exterior (color variations) up to 2000 litres
n Rust prevention paint outside (from 3000 litres)
ACCESSORIES
n Finned-tube heat exchanger RWT2-180 (1.8 m2)
n Finned-tube heat exchanger RWT2-230 (2.3 m2)
n Finned-tube heat exchanger RWT2-360 (3.6 m2)
n Finned-tube heat exchanger RWT2-450 (4.5 m2)
n Heating installation RSW 2-9 U
n Heating installation RSW 2-24 U
n Heating installation RSW 2-45 U
n Screw-type series „SH“
(1.5 to 9.0 kW except PSRR 1000, 1500, 2000 and 1000 and 1500 PZRR)
nStainless steel corrugated hose connection for PS connections
n Conduit Fitting R 1‘‘(electrical isolation)
BUFFER TANKSPECIFICATIONS AND ACCESSORIES
NEW
Keybenefits
n Everything from one source - storage tank and insulati
on are manufactured by Austria Email
n Perfect corrosion protection - storage tank with ena
melled powder coating outside
n Stable, shape-retaining polystyrene cladding
n Perfect fit, therefore no thermal losses
n Insulated port caps for the connectors
n Up to € 3500 savings on energy costs over the lifetime