Perhitungan Tebal Plat Lantai :
Data - Data :Mutu Baja fy = 300 mpaMutu Beton fc = 30 mpaPanajang lx = 4 mTinggi Balok (h) = 1/10*L = 0.40 ~ 0.40 mLebar Balok (b) = 1/2 x h = 0.20 ~ 0.20 mPanjang ly = 4.5 mTinggi Balok (h) = 1/10*L = 0.45 ~ 0.50 mLebar Balok (b) = 1/2 x h = 0.23 ~ 0.20 mRencana Tinggi Lantai = 4 mRencana Tebal Pelat Lantai = 0.12 mRencana Dimensi Kolom = 50 x 50
= 9.556 = 95.55556 mm < 120 mm45.000Digunakan Tebal Pelat : Pelat Lantai = 120 mm
Pelat Atap = 100 mm
DIHITUNG TEBAL PLAT SMPAI 6 CINNNN!!!
h1=λn×[0 . 8+
fy1500 ]
36+9 β
• Pembebanan Pelat
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 288 kg/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 42 kg/m²Berat Keramik per m² = 1 x 24 = 24 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 397 kg/m²
Beban Hidup Gedung Pertemuan = 400 Kg/m²
Beban Kombinasi Pada Lantai = 1116.4 Kg/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 240 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 283 kg/m²
Beban Hidup Air Hujan = 100 Kg/m²
Beban Kombinasi Pada Atap = 499.6 Kg/m²
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perencanaan Pelat Lantai
• Pelat Type A
ly 450
20/40
15/30
lx400
ly=
450= 1.125 ~ 1.1
lx 400
1
2
3
A B C D
22
3.0000 2.0000 3.0000
3.5000
1.5000
3.5000
3.5000
Plat LantaiTangga
A
BC
A
• Perhitungan Momen Pelat
Nilai momen yang bekerja pada pelat lantai ditentukan dengan Tabel Koefisien Momen PBI-1971.
Plat Type A Terjepit Penuh
Mlx = 0.001 x q x x X= 0.001 x 1116.4 x 16 x 28= 500.15 kg/m = 5.0015 kN/m
Mtx = -0.001 x q x x X= -0.001 x 1116.4 x 16 x 64= -1143 kg/m = -11.43 kN/m
Mly = 0.001 x q x x X= 0.001 x 1116.4 x 16 x 20= 357 kg/m = 3.5725 kN/m
Mty = -0.001 x q x x X= -0.001 x 1116.4 x 16 x 56= ### kg/m = -10 kN/m
• Rasio Tulangan Maximum= 0.85 Karena f'c = 30 mpa
=0.85 x 0.85 x 30
x600
300 600 + 300= 0.07225 x 0.66667= 0.04817
= 0.75 x= 0.75 x 0.04817= 0.03613
m = fy = 300 =11.76
0.85 . f'c 0.85 x 30
• Rasio Tulangan Perlu
Rn = Mn=
12503680= 2.22288
1000 x 5625
ρ = 0.085 x 0.09134= 0.0078 <
Maka di gunakan , ρmin = 0.005
• Luas Tulangan Perlu
As = ρ.b.d= 0.005 x 1000 x 85= 397
dicoba dengan Ø 10 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 100 x 1000397
= 197.9 mm ~ 200 mm
Digunakan diameter dan Jarak Tulangan Ø 10 - 200Kontrol Jarak antar tulangan :
s < 3h = 200 < 360 ( OK )!!!
s < 5h = 200 < 600 ( OK )!!!
β1
ρb
ρmax ρb
b .d²
ρmin
mm²
fyfy
fcb 600
600'85.0 1
ρ= 1m (1−√1−2 x m x Rn
fy )
14⋅π⋅φ2⋅b
As
• Tulangan Suhu dan SusutSNI’1991 tidak mengatur untuk tulangan polos maka dipakai persyaratan dari PBI’71.
= 20% x= 20% x 397= 79.3333
dicoba dengan Ø 8 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 64 x 100079.33
= 633.28 mm ~ 300 mm
Digunakan diameter dan Jarak Tulangan Ø 8 - 300Kontrol Jarak antar tulangan :
s < 3h = 300 < 360 ( OK )!!!
s < 5h = 300 < 600 ( OK )!!!
As susut As pokok
14⋅π⋅φ2⋅b
As
• Pembebanan Pelat
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 288 kg/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 42 kg/m²Berat Keramik per m² = 1 x 24 = 24 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 397 kg/m²
Beban Hidup Gedung Pertemuan = 400 Kg/m²
Beban Kombinasi Pada Lantai = 1116.40 Kg/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 240 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 283 kg/m²
Beban Hidup Air Hujan = 100 Kg/m²
Beban Kombinasi Pada Atap = 499.600 Kg/m²
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perencanaan Pelat Lantai
• Pelat Type B
350 ly20/40
15/30
lx200
ly=
350= 1.75 ~ 1.8
lx 200
1
2
3
A B C D
22
3.0000 2.0000 3.0000
3.5000
1.5000
3.5000
3.5000
Plat LantaiTangga
A
BC
B
• Perhitungan Momen Pelat
Nilai momen yang bekerja pada pelat lantai ditentukan dengan Tabel Koefisien Momen PBI-1971.
Plat Type A Terjepit Penuh
Mlx = 0.001 x q x x X= 0.001 x 1116.4 x 4 x 40= 178.62 kg/m = 1.7862 kN/m
Mtx = -0.001 x q x x X= -0.001 x 1116.4 x 4 x 82= -366 kg/m = -3.662 kN/m
Mly = 0.001 x q x x X= 0.001 x 1116.4 x 4 x 13= 58 kg/m = 0.5805 kN/m
Mty = -0.001 x q x x X= -0.001 x 1116.4 x 4 x 57= -254.54 kg/m = -2.545 kN/m
• Rasio Tulangan Maximum= 0.85 Karena f'c = 30 mpa
=0.85 x 0.85 x 30
x600
300 600 + 300= 0.07225 x 0.66667= 0.04817
= 0.75 x= 0.75 x 0.04817= 0.03613
m = fy = 300 =11.76
0.85 . f'c 0.85 x 30
• Rasio Tulangan Perlu
Rn = Mn=
3181740= 0.56564
1000 x 5625
ρ = 0.085 x 0.02243= 0.0019 <
Maka di gunakan , ρmin = 0.005
• Luas Tulangan Perlu
As = ρ.b.d= 0.005 x 1000 x 85= 397
dicoba dengan Ø 10 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 100 x 1000397
= 197.9 mm ~ 200 mm
Digunakan diameter dan Jarak Tulangan Ø 10 - 200Kontrol Jarak antar tulangan :
s < 3h = 200 < 360 ( OK )!!!
s < 5h = 200 < 600 ( OK )!!!
β1
ρb
ρmax ρb
b .d²
ρmin
mm²
fyfy
fcb 600
600'85.0 1
ρ= 1m (1−√1− 2 x m x Rn
fy )
14⋅π⋅φ2⋅b
As
• Tulangan Suhu dan SusutSNI’1991 tidak mengatur untuk tulangan polos maka dipakai persyaratan dari PBI’71.
= 20% x= 20% x 397= 79.3333
dicoba dengan Ø 8 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 64 x 100079.33
= 633.28 mm ~ 300 mm
Digunakan diameter dan Jarak Tulangan Ø 8 - 300Kontrol Jarak antar tulangan :
s < 3h = 300 < 360 ( OK )!!!
s < 5h = 300 < 600 ( OK )!!!
As susut As pokok
14⋅π⋅φ2⋅b
As
• Pembebanan Pelat
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 288 kg/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 42 kg/m²Berat Keramik per m² = 1 x 24 = 24 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 397 kg/m²
Beban Hidup Gedung Pertemuan = 400 Kg/m²
Beban Kombinasi Pada Lantai = 1116.40 Kg/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 240 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 283 kg/m²
Beban Hidup Air Hujan = 100 Kg/m²
Beban Kombinasi Pada Atap = 499.600 Kg/m²
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perencanaan Pelat Lantai
• Pelat Type C
150 lx
20/40
15/30
ly300
ly=
300= 2 ~ 2.0
lx 150
1
2
3
A B C D
22
3.0000 2.0000 3.0000
3.5000
1.5000
3.5000
3.5000
Plat LantaiTangga
A
BC
C
• Perhitungan Momen Pelat
Plat Type A Terjepit Penuh
Mlx = 0.001 x q x x X= 0.001 x 1116.4 x 2.25 x 41= 102.99 kg/m = 1.0299 kN/m
Mtx = -0.001 x q x x X= -0.001 x 1116.4 x 2.25 x 83= -208 kg/m = -2.085 kN/m
Mly = 0.001 x q x x X= 0.001 x 1116.4 x 2.25 x 12= 30 kg/m = 0.3014 kN/m
Mty = -0.001 x q x x X= -0.001 x 1116.4 x 2.25 x 57= -143.18 kg/m = -1.432 kN/m
• Rasio Tulangan Maximum= 0.85 Karena f'c = 30 mpa
=0.85 x 0.85 x 30
x600
300 600 + 300= 0.07225 x 0.66667= 0.04817
= 0.75 x= 0.75 x 0.04817= 0.03613
m = fy = 300 =11.76
0.85 . f'c 0.85 x 30
• Rasio Tulangan Perlu
Rn = Mn=
1789729= 0.31817
1000 x 5625
ρ = 0.085 x 0.01256= 0.0011 <
Maka di gunakan , ρmin = 0.005
• Luas Tulangan Perlu
As = ρ.b.d= 0.005 x 1000 x 85= 397
dicoba dengan Ø 10 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 100 x 1000397
= 197.9 mm ~ 200 mm
Digunakan diameter dan Jarak Tulangan Ø 10 - 200Kontrol Jarak antar tulangan :
s < 3h = 200 < 360 ( OK )!!!
s < 5h = 200 < 600 ( OK )!!!
β1
ρb
ρmax ρb
b .d²
ρmin
mm²
fyfy
fcb 600
600'85.0 1
ρ= 1m (1−√1−2 x m x Rn
fy )
14⋅π⋅φ2⋅b
As
• Tulangan Suhu dan SusutSNI’1991 tidak mengatur untuk tulangan polos maka dipakai persyaratan dari PBI’71.
= 20% x= 20% x 397= 79.3333
dicoba dengan Ø 8 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 64 x 100079.33
= 633.28 mm ~ 300 mm
Digunakan diameter dan Jarak Tulangan Ø 8 - 300Kontrol Jarak antar tulangan :
s < 3h = 300 < 360 ( OK )!!!
s < 5h = 300 < 600 ( OK )!!!
As susut As pokok
14⋅π⋅φ2⋅b
As
• Pembebanan Pelat
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 288 kg/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 42 kg/m²Berat Keramik per m² = 1 x 24 = 24 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 397 kg/m²
Beban Hidup Gedung Pertemuan = 400 Kg/m²
Beban Kombinasi Pada Lantai = 1116.40 Kg/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 240 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 283 kg/m²
Beban Hidup Air Hujan = 100 Kg/m²
Beban Kombinasi Pada Atap = 499.600 Kg/m²
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perencanaan Pelat Atap
• Pelat Type A
200 ly
20/40
15/30
lx150
ly=
200= 1.33333 ~ 1.4
lx 150
1
2
A B C E FD
1.5000
22
2.0000
1.5000 1.5000
2.0000
1.5000 1.5000 2.0000 1.5000
Plat AtapRencana Atap
A
B
A
• Perhitungan Momen Pelat
Nilai momen yang bekerja pada pelat lantai ditentukan dengan Tabel Koefisien Momen PBI-1971.
Plat Type A Terjepit Elastis Penuh
Mlx = 0.001 x q x x X= 0.001 x 499.6 x 2.25 x 53= 59.58 kg/m = 0.5958 kN/m
Mtx = -0.001 x q x x x= -0.001 x 499.6 x 2.25 x 53= -59.58 kg/m = -0.596 kN/m
Mly = 0.001 x q x x X= 0.001 x 499.6 x 2.25 x 38= 43 kg/m = 0.4272 kN/m
Mty = -0.001 x q x x X= -0.001 x 499.6 x 2.25 x 38= -42.72 kg/m = -0.427 kN/m
• Rasio Tulangan Maximum= 0.85 Karena f'c = 30 mpa
=0.85 x 0.85 x 30
x600
300 600 + 300= 0.07225 x 0.66667= 0.04817
= 0.75 x= 0.75 x 0.04817= 0.03613
m = fy = 300 =11.76
0.85 . f'c 0.85 x 30
• Rasio Tulangan Perlu
Rn = Mn=
533947= 0.12638
1000 x 4225
ρ = 0.085 x 0.00497= 0.0004 <
Maka di gunakan , ρmin = 0.005
• Luas Tulangan Perlu
As = ρ.b.d= 0.005 x 1000 x 65= 303
dicoba dengan Ø 10 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 100 x 1000303
= 258.79 mm ~ 200 mm
Digunakan diameter dan Jarak Tulangan Ø 10 - 200Kontrol Jarak antar tulangan :
s < 3h = 200 < 300 ( OK )!!!
s < 5h = 200 < 500 ( OK )!!!
β1
ρb
ρmax ρb
b .d²
ρmin
mm²
fyfy
fcb 600
600'85.0 1
ρ= 1m (1−√1−2 x m x Rn
fy )
14⋅π⋅φ2⋅b
As
• Tulangan Suhu dan SusutSNI’1991 tidak mengatur untuk tulangan polos maka dipakai persyaratan dari PBI’71.
= 20% x= 20% x 350= 70
dicoba dengan Ø 8 mmJarak antar tulangan (s) :
s = = 0.25 x 3.14 x 64 x 100070.00
= 717.71 mm ~ 250 mm
Digunakan diameter dan Jarak Tulangan Ø 8 - 250Kontrol Jarak antar tulangan :
s < 3h = 250 < 300 ( OK )!!!
s < 5h = 250 < 500 ( OK )!!!
As susut As pokok
14⋅π⋅φ2⋅b
As
• Pembebanan Pelat
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 288 kg/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 42 kg/m²Berat Keramik per m² = 1 x 24 = 24 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 397 kg/m²
Beban Hidup Gedung Pertemuan = 400 Kg/m²
Beban Kombinasi Pada Lantai = 1116.40 Kg/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 240 kg/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 25 kg/m²Berat Plafond + Penggantung per m² = 11 + 7 = 18 kg/m²
= 283 kg/m²
Beban Hidup Air Hujan = 100 Kg/m²
Beban Kombinasi Pada Atap = 499.600 Kg/m²
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perencanaan Pelat Atap
• Pelat Type B
150 ly
20/40
15/30
lx150
ly=
150= 1 ~ 1.0
lx 150
1
2
A B C E FD
1.5000
22
2.0000
1.5000 1.5000
2.0000
1.5000 1.5000 2.0000 1.5000
Plat AtapRencana Atap
A
B
B
• Perhitungan Momen Pelat
Nilai momen yang bekerja pada pelat lantai ditentukan dengan Tabel Koefisien Momen PBI-1971.Plat Type A Terjepit Elastis Penuh
Mlx = 0.001 x q x x X= 0.001 x 499.6 x 2.25 x 36= 40.47 kg/m = 0.4047 kN/m
Mtx = -0.001 x q x x x= -0.001 x 499.6 x 2.25 x 36= -40.47 kg/m = -0.405 kN/m
Mly = 0.001 x q x x X= 0.001 x 499.6 x 2.25 x 36= 40 kg/m = 0.4047 kN/m
Mty = -0.001 x q x x X= -0.001 x 499.6 x 2.25 x 36= -40.47 kg/m = -0.405 kN/m
Panjang Lx Lx = 4.000 mPanjang Bentang Ly Ly = 4.500 mTinggi Antar Lantai H = 4.000 mtebal pelat atap = 0.120 mtebal pelat atap = 0.100 mDimensi Balok arah x :Tinggi Balok bentang arah x hx = (1/10) x Lx hx = 0.40 mLebar Balok bentang arah x bx = (1/2) x hx bx = 0.20 mDimensi Balok arah y :Tinggi Balok Bentang arah y hy = (1/10) x Ly hy = 0.45 ~ 0.40 mLebar Balok Bentang arah y by = (1/2) x hy by = 0.23 ~ 0.20 mDimensi Kolom :
Minimal Sama Dengan Lebar Balok hk = 0.400 mMinimal Sama Dengan Lebar Balok bk = 0.400 m
1. Perhitungan Beban Pada Pelat Lantai :
Berat Sendiri Pelat tebal 12 cm = 0.120 x 2400 = 0.288 ton/m²Berat Adukan tebal 2 cm per m² = 2 x 21 = 0.042 ton/m²Berat Keramik per m² = 1 x 24 = 0.024 ton/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 0.025 ton/m²Berat Plafond + Penggantung per m² = 11 + 7 = 0.018 ton/m²
= 0.397 ton/m²
Beban Hidup Gedung Pertemuan = 0.400 ton/m²
Beban Kombinasi Pada Lantai = 1.12 ton/m²
2. Perhitungan Beban Pada Pelat Atap:
Berat Sendiri Pelat tebal 10 cm = 0.100 x 2400 = 0.240 ton/m²Berat Mekanikal Elektrikal per m² = 1 x 25 = 0.025 ton/m²Berat Plafond + Penggantung per m² = 11 + 7 = 0.018 ton/m²
= 0.283 ton/m²
Beban Hidup Air Hujan = 0.100 Kg/m²
Beban Kombinasi Pada Atap = 0.500 Kg/m²
• Penentuan Dimensi Penampang Struktur
hpelat
hatap
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL1
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL1
• Beban Kombinasi (Qu) :Qu1 = 1,2 x DL1 + 1,6 x LL1 Qu1
• Perhitungan Pembebanan Akibat Beban Mati atau Death Load (DL) :
DL2
• Perhitungan Pembebanan Akibat Beban Hidup atau Live Load (LL) :LL2
• Beban Kombinasi (Qu) :Qu2 = 1,2 x DL2 + 1,6 x LL2 Qu2
• Perhitungan Beban Merata (Q) dan Beban Terpusat (P)
Perhitungan Beban Merata Pada Pelat Lantai
Perhitungan Beban Merata Bentang A - B atau Q1
- Berat Trapesium E = 0.37 x 1.116 x 1 = 0.412- Berat Segitiga A = 1.00 x 1.116 x 1 = 1.116- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192- Berat Dinding = 0.250 x 4.000 x 1 = 1.000
Q1 = 2.721
Perhitungan Beban Merata Bentang B - C atau Q2
- Berat Segitiga C = 0.667 x 1.116 x 2 x 1 = 1.489- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192- Berat Dinding = 0.250 x 4.000 x 1 = 1.000
Q2 = 2.681
Perhitungan Beban Merata Bentang C - D atau Q3
- Berat Segitiga A = 1.00 x 1.116 x 1 = 1.116- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192- Berat Dinding = 0.250 x 4.000 x 1 = 1.000
Q3 = 2.308
Perhitungan Beban Merata Pada Pelat Atap
Perhitungan Beban Merata Bentang A - C atau Q4
- Berat Segitiga G = 0.50 x 0.500 x 2 x 1 = 0.500- Berat Segitiga I = 0.50 x 0.500 x 2 x 1 = 0.500- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192
Q4 = 1.191
Perhitungan Beban Merata Bentang C - D atau Q5
- Berat Trapesium M = 0.36 x 0.500 x 1 = 0.181- Berat Segitiga K 0.67 x 0.500 x 1 = 0.333- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192
Q5 = 0.706
Perhitungan Beban Merata Bentang D - F atau Q6
- Berat Segitiga G = 0.50 x 0.500 x 2 x 1 = 0.500- Berat Segitiga I = 0.50 x 0.500 x 2 x 1 = 0.500- Berat Sendiri Balok = 0.20 x 0.400 x 2.400 x 1 = 0.192
Q6 = 1.191
ton/m¹ton/m¹ton/m¹ton/m¹ton/m¹
ton/m¹ton/m¹ton/m¹ton/m¹
ton/m¹ton/m¹ton/m¹ton/m¹
ton/m¹ton/m¹ton/m¹ton/m¹
ton/m¹ton/m¹ton/m¹ton/m¹
ton/m¹ton/m¹ton/m¹ton/m¹
Perhitungan Beban Terpusat Pada Pelat Lantai
Perhitungan Beban Terpusat Bentang A - A atau P1
- Berat Segitiga F = 0.500 x 1.116 x 0.5 = 0.279 ton- Berat Trapesium B = 0.681 x 1.116 x 0.5 = 0.380 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton- Berat Dinding = 0.250 x 4.000 x 1.750 = 1.750 ton- Berat Sendiri Kolom = 0.400 x 0.400 x 2.400 x 4.000 = 1.536 ton
P1 = 4.281 ton
Perhitungan Beban Terpusat Bentang B - B atau P2
- Berat Segitiga F = 0.500 x 1.116 x 0.5 = 0.279 ton- Berat Trapesium B = 0.681 x 1.116 x 0.5 = 0.380 ton- Berat Trapesium D = 0.486 x 1.116 x 1 = 0.543 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton- Berat Dinding = 0.250 x 4.000 x 1.750 = 1.750 ton- Berat Sendiri Kolom = 0.400 x 0.400 x 2.400 x 4.000 = 1.536 ton
P2 = 4.824 ton
Perhitungan Beban Terpusat Bentang C- C atau P3
- Berat Trapesium B = 0.681 x 1.116 x 1 = 0.760 ton- Berat Trapesium D 0.486 x 1.116 x 1 = 0.543 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton- Berat Dinding = 0.250 x 4.000 x 1.750 = 1.750 ton- Berat Sendiri Kolom = 0.400 x 0.400 x 2.400 x 4.000 = 1.536 ton
P3 = 4.926 ton
Perhitungan Beban Terpusat Bentang D- D atau P4
- Berat Trapesium B = 0.681 x 1.116 x 1 = 0.760 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton- Berat Dinding = 0.250 x 4.000 x 1.750 = 1.750 ton- Berat Sendiri Kolom = 0.400 x 0.400 x 2.400 x 4.000 = 1.536 ton
P4 = 4.382 ton
Perhitungan Beban Terpusat Pada Pelat Atap`
Perhitungan Beban Terpusat Bentang A - A atau P5
- Berat Segitiga J = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Trapesium H = 0.362 x 0.500 x 0.5 = 0.090 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P5 = 0.551 tonPerhitungan Beban Terpusat Bentang B - B atau P6
- Berat Segitiga J = 0.500 x 0.500 x 1 = 0.250 ton- Berat Trapesium H = 0.362 x 0.500 x 1 = 0.181 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P6 = 0.767 tonPerhitungan Beban Terpusat Bentang C - C atau P7
- Berat Segitiga J = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Segitiga N = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Trapesium H 0.362 x 0.500 x 0.5 = 0.090 ton- Berat Segetiga L 0.667 x 0.500 x 0.5 = 0.167 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P7 = 0.843 ton
Perhitungan Beban Terpusat Bentang D - D atau P8
- Berat Segitiga J = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Segitiga N = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Trapesium H 0.362 x 0.500 x 0.5 = 0.090 ton- Berat Segetiga L 0.667 x 0.500 x 0.5 = 0.167 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P8 = 0.843 ton
Perhitungan Beban Terpusat Bentang E - E atau P9
- Berat Trapesium H = 0.500 x 0.500 x 1 = 0.250 ton- Berat Segetiga L = 0.362 x 0.500 x 1 = 0.181 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P9 = 0.767 ton
Perhitungan Beban Terpusat Bentang F - F atau P10
- Berat Segitiga J = 0.500 x 0.500 x 0.5 = 0.125 ton- Berat Trapesium H = 0.362 x 0.500 x 0.5 = 0.090 ton- Berat Sendiri Balok = 0.200 x 0.400 x 2.400 x 1.750 = 0.336 ton
P10 = 0.551 ton
Gambar Pembebanan Pada PortalA B C D
Q1 = 2.637 ton/mQ2 = 2.597 ton/m
Q3 = 2.224 ton/m
Q4 =1.107 ton/m Q5 =0.622 ton/mQ6 = 1.107 ton/m
P1 = 4.281 ton P2 = 4.824 ton P3 = 4.926 ton P4 = 4.382 ton