DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.41
(120)
BSC3i/TCSM3i upgradefor SDH/Sonet equipmentprotection (S12 -
S14TCSM HW)Release Delivery: HW UpgradeProduct Family: Radio
ControllersProduct: BSC3i 1000/2000, UpgradedFlexi BSCRelease: S16
onwards
Nokia Solutions and Networks is continually striving to reduce
the adverse environmental effects of itsproducts and services. We
would like to encourage you as our customers and users to join us
inworking towards a cleaner, safer environment. Please recycle
product packaging and follow therecommendations for power use and
proper disposal of our products and their components.
If you should have questions regarding our Environmental Policy
or any of the environmental serviceswe offer, please contact us at
Nokia Solutions and Networks for additional information.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.42
(120)
Table of Contents1 Purpose
..................................................................................................................................................
62 Scope of applications
..............................................................................................................................
73 Using the document
................................................................................................................................
8
3.1 General info
.......................................................................................................................................................
83.2 Upgrade macro
..................................................................................................................................................
8
3.2.1 Structure
......................................................................................................................................
83.2.2 Communication
............................................................................................................................
93.2.3 Log files
.....................................................................................................................................
10
4 Introduction
...........................................................................................................................................
124.1 Combined TCSM3i equipment before
upgrade..................................................................................................
14
4.1.1 TCSA-0 cabinet
..........................................................................................................................
144.1.2 TCSA-1 cabinet
..........................................................................................................................
154.1.3 TCSA-2 cabinet
..........................................................................................................................
15
4.2 Combined TCSM3i equipment after upgrade
....................................................................................................
164.2.1 TCSA-0 cabinet
..........................................................................................................................
164.2.2 TCSA-1 cabinet
..........................................................................................................................
164.2.3 TCSA-2 cabinet
..........................................................................................................................
17
5 Pre-requirements
..................................................................................................................................
185.1 Pre-requirements & Actions needed prior upgrade
............................................................................................
185.2 Restrictions
.....................................................................................................................................................
185.3 Needed documentation
....................................................................................................................................
195.4 Needed equipment
..........................................................................................................................................
195.5 HIT and upgrade
macros..................................................................................................................................
20
5.5.1 System requirements for HIT
......................................................................................................
205.5.2 Installing HIT
..............................................................................................................................
205.5.3 Installing HIT upgrading macros
..................................................................................................
205.5.4 HIT
settings................................................................................................................................
215.5.5 Connection settings
....................................................................................................................
215.5.6 Starting the HIT application / macro execution
.............................................................................
41
6 Fallback copying of the current package
................................................................................................
497 BSC configuration printout (pre-check)
..................................................................................................
508 SDH/Sonet equipment protection upgrade for combined TCSM3i
(OFFLINE) ........................................ 51
8.1 Choose TCSA cabinet to be upgraded
..............................................................................................................
538.2 Move traffic from STMU which will be upgraded
................................................................................................
538.3 Delete old configurations & equipment
..............................................................................................................
538.4 Install redundant ETS2 plug-in unit(s)
...............................................................................................................
548.5 Make cabling changes and install new cables
...................................................................................................
548.6 New configuration & equipment with HW protection
..........................................................................................
54
8.6.1 BSC3i 1000/2000 or upgraded Flexi
BSC....................................................................................
558.6.2 New Delivery Flexi
BSC..............................................................................................................
63
9 SDH/Sonet equipment protection upgrade for combined TCSM3i
(LIVE) ............................................... 719.1 TCSA-0
...........................................................................................................................................................
73
9.1.1 Remove protection groups
..........................................................................................................
739.1.2 Remove interfaces from SET-144 and disconnect effected
TCSM(s) ............................................ 739.1.3 Change
SET-144 to SE-NH state
................................................................................................
739.1.4 Delete SET-144
.........................................................................................................................
739.1.5 Create SET-138
.........................................................................................................................
749.1.6 Make cabling changes
................................................................................................................
749.1.7 Change SET-138 to WO-EX state
...............................................................................................
759.1.8 Create interface(s) from SET-138 and connect related
TCSM(s) .................................................. 759.1.9
Remove interfaces from SET-146 and disconnect effected TCSM(s)
............................................ 759.1.10 Change
STMU-36 SE-NH state
..................................................................................................
759.1.11 Delete SET-146 and STMU-36
...................................................................................................
769.1.12 Insert a new ETS2 plug-in unit to GTIC-2 and GTIC-3 track
7 ...................................................... 769.1.13
Create STMU-36 to GTIC-2
........................................................................................................
76
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.43
(120)
9.1.14 Create SET-144
.........................................................................................................................
779.1.15 Make cabling changes
................................................................................................................
779.1.16 Create interface(s) from SET-144 and connect related
TCSM(s) .................................................. 789.1.17
Change STMU-36 to WO-EX state
..............................................................................................
789.1.18 Remove interfaces from SET-152 and disconnect effected
TCSM(s) ............................................ 789.1.19
Change STMU-38 SE-NH state
..................................................................................................
789.1.20 Delete SET-152
.........................................................................................................................
799.1.21 Create SET-146
.........................................................................................................................
799.1.22 Make cabling changes
................................................................................................................
809.1.23 Create interface(s) from SET-146 and connect related
TCSM(s) .................................................. 809.1.24
Change SET-146 to WO-EX state
...............................................................................................
819.1.25 Delete STMU-38
........................................................................................................................
819.1.26 Create STMU-33/35/37
..............................................................................................................
819.1.27 Install new cables and modules
..................................................................................................
829.1.28 Create protection groups
............................................................................................................
839.1.29 Change STMU-33/35/37 to WO-EX
............................................................................................
84
9.2 TCSA-1
...........................................................................................................................................................
849.2.1 Remove protection groups
..........................................................................................................
849.2.2 Remove interfaces from SET-160, SET-162 and disconnect
effected TCSM(s) ............................ 849.2.3 Change
STMU-40 SE-NH state
..................................................................................................
859.2.4 Delete SET-160 and SET- 162
...................................................................................................
859.2.5 Delete STMU-40
........................................................................................................................
869.2.6 Create STMU-38 to GTIC-5
........................................................................................................
869.2.7 Create SET-152 and SET-154
....................................................................................................
869.2.8 Create interface(s) from SET-152, SET-154 and connect
related TCSM(s)................................... 879.2.9 Change
STMU-38 to WO-EX
......................................................................................................
879.2.10 Remove interfaces from SET-168 and disconnect effected
TCSM(s) ............................................ 879.2.11
Change STMU-42 SE-NH state
..................................................................................................
879.2.12 Delete SET-168
.........................................................................................................................
879.2.13 Delete STMU-42
........................................................................................................................
889.2.14 Create STMU-40
........................................................................................................................
889.2.15 Create SET-160
.........................................................................................................................
899.2.16 Create interface(s) from SET-160 and connect related
TCSM(s) .................................................. 899.2.17
Change STMU-40 to WO-EX
......................................................................................................
899.2.18 Change SET-176 to SE-NH state
................................................................................................
899.2.19 Delete SET-176
.........................................................................................................................
909.2.20 Create SET-162
.........................................................................................................................
909.2.21 Make cabling changes
................................................................................................................
919.2.22 Change SET-162 to WO-EX state
...............................................................................................
919.2.23 Create interface(s) from SET-162 and connect related
TCSM(s) .................................................. 919.2.24
Remove interfaces from SET-178 and disconnect effected TCSM(s)
............................................ 929.2.25 Change
STMU-44 to SE-NH
.......................................................................................................
929.2.26 Delete SET-178
.........................................................................................................................
929.2.27 Delete STMU-44
........................................................................................................................
929.2.28 Insert a new ETS2 plug-in unit to GTIC-5 and GTIC-6 track
7 ...................................................... 939.2.29
Create STMU-42 to GTIC-5
........................................................................................................
939.2.30 Create SET-168
.........................................................................................................................
939.2.31 Make cabling changes
................................................................................................................
949.2.32 Create interface(s) from SET-168 and connect related
TCSM(s) .................................................. 949.2.33
Change STMU-42 WO-EX state
.................................................................................................
949.2.34 Remove interfaces from SET-184 and disconnect effected
TCSM(s) ............................................ 949.2.35
Change STMU-46 to SE-NH
state...............................................................................................
959.2.36 Delete SET-184
.........................................................................................................................
959.2.37 Create SET-170
.........................................................................................................................
959.2.38 Make cabling changes
................................................................................................................
969.2.39 Create interface(s) from SET-170 and connect related
TCSM(s) .................................................. 969.2.40
Change SET-170 to WO-EX state
...............................................................................................
969.2.41 Delete STMU-46
........................................................................................................................
979.2.42 Create STMU-39/41/43
..............................................................................................................
979.2.43 Install new cables and modules
..................................................................................................
98
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.44
(120)
9.2.44 Create protection groups
............................................................................................................
999.2.45 Change STMU-39/41/43 to WO-EX
............................................................................................
99
9.3 TCSA-2
.........................................................................................................................................................
1009.3.1 Remove protection groups
........................................................................................................
1009.3.2 Remove interfaces from SET-192, SET-194 and disconnect
effected TCSM(s) .......................... 1009.3.3 Change STMU-48
SE-NH state
................................................................................................
1009.3.4 Delete SET-192 and SET- 194
.................................................................................................
1009.3.5 Delete STMU-48
......................................................................................................................
1019.3.6 Create STMU-44
......................................................................................................................
1019.3.7 Create SET-176 and SET-178
..................................................................................................
1029.3.8 Create interface(s) from SET-176, SET-178 and connect
related TCSM(s)................................. 1029.3.9 Change
STMU-44 to WO-EX
....................................................................................................
1029.3.10 Remove interfaces from SET-200 and disconnect effected
TCSM(s) .......................................... 1029.3.11 Change
STMU-50 SE-NH state
................................................................................................
1039.3.12 Delete SET-200
.......................................................................................................................
1039.3.13 Delete STMU-50
......................................................................................................................
1039.3.14 Create STMU-46
......................................................................................................................
1049.3.15 Create SET-184
.......................................................................................................................
1049.3.16 Create interface(s) from SET-184 and connect related
TCSM(s) ................................................ 1049.3.17
Change STMU-46 to WO-EX
....................................................................................................
1059.3.18 Change SET-208 to SE-NH state
..............................................................................................
1059.3.19 Delete SET-208
.......................................................................................................................
1059.3.20 Create SET-186
.......................................................................................................................
1059.3.21 Make cabling changes
..............................................................................................................
1069.3.22 Change SET-186 to WO-EX state
.............................................................................................
1079.3.23 Create interface(s) from SET-186 and connect related
TCSM(s) ................................................ 1079.3.24
Remove interfaces from SET-210 and disconnect effected TCSM(s)
.......................................... 1079.3.25 Change STMU-52
SE-NH
.........................................................................................................
1079.3.26 Delete SET-210
.......................................................................................................................
1079.3.27 Delete STMU-52
......................................................................................................................
1089.3.28 Insert a new ETS2 plug-in unit to GTIC-8 and GTIC-9 track
7 .................................................... 1089.3.29
Create STMU-48 to GTIC-8
......................................................................................................
1089.3.30 Create SET-192
.......................................................................................................................
1089.3.31 Make cabling changes
..............................................................................................................
1099.3.32 Create interface(s) from SET-192 and connect related
TCSM(s) ................................................ 1099.3.33
Change STMU-48 WO-EX state
...............................................................................................
1099.3.34 Remove interfaces from SET-216 and disconnect effected
TCSM(s) .......................................... 1109.3.35 Change
STMU-54 SE-NH state
................................................................................................
1109.3.36 Delete SET-216
.......................................................................................................................
1109.3.37 Create SET-194
.......................................................................................................................
1119.3.38 Make cabling changes
..............................................................................................................
1119.3.39 Create interface(s) from SET-194 and connect related
TCSM(s) ................................................ 1129.3.40
Change SET-194 to WO-EX state
.............................................................................................
1129.3.41 Delete STMU-54
......................................................................................................................
1129.3.42 Create STMU-45/47/49
............................................................................................................
1129.3.43 Install new cables and modules
................................................................................................
1139.3.44 Create protection groups
..........................................................................................................
1149.3.45 Change STMU-45/47/49 to WO-EX
..........................................................................................
115
10 Copy the HW equipment database information to the disk (DBC)
......................................................... 11611
Actions after upgrade & Post conditions
..............................................................................................
117
11.1 BSS Integration
.............................................................................................................................................
11711.2 BSC configuration printout (post-check)
..........................................................................................................
11711.3 Return to the old HW configuration
.................................................................................................................
117
12 Appendix
.............................................................................................................................................
11812.1 Appendix1: Combined TCSM3i cables
............................................................................................................
118
Contact:
Contact your local Nokia Solutions and Networks support
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.45
(120)
Summary of changes:
1.0-0 1st approved version1.1-0 Added CR75 details1.2-0 Added
connection settings for Linux in chapter 5.5.5.2.1.3-0 Added note
regarding COM issue in HIT3.3 in chapter
5.5.5.1.2 and 5.5.5.2.2.1.4-0 Removed note regarding COM issue
from chapters
5.5.5.1.2 and 5.5.5.2.2.Also updated the hit version
as3.4-0.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.46
(120)
1 PURPOSE
This document describes the implementation of changing line
protection of ETS2 plug-in unit to equipmentprotection. The
SDH/Sonet equipment protection implementation is available for
third generation DX200 BSC3iwith following options:
- Combined BSC3i1000/TCSM3i
- Combined Flexi BSC/TCSM3i
The upgrade can be done either the whole TCSA cabinet at a time
or one STM-1/OC-3 at a time. During theactual upgrade the traffic
needs to be re-directed and units cannot carry traffic. With one
STM-1/OC-3 at the timeoption, the traffic lost will be lower.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.47
(120)
2 SCOPE OF APPLICATIONS
The BSC/TCSM upgrade for SDH/Sonet equipment protection
implementation is available for third generationDX200 BSC3i in S16
release level onwards.The procedure cannot be implemented to STMU
(ETS2 plug-in unit) unit without traffic interruption. Traffic
mustbe moved from concerning ETS2 plug-in unit before the actual
upgrade.With this procedure user can choose upgrade to be done as
whole TCSA Cabinet at a time or one STM-1/OC3 ata time. The whole
TCSA cabinet at a time means that the traffic is re-directed from
the whole cabinet. The oneSTM-1/OC-3 at a time means that only
minor traffic re-directions are needed (from old configurations
unit(s)which are needed to be deleted).Procedure must be performed
locally at BSC site.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.48
(120)
3 USING THE DOCUMENT
3.1 General info
The BSC/TCSM upgrade for SDH/Sonet equipment protection can be
done using the HIT (Holistic IntegrationTester) software tool.
Optional way is to make the upgrade manually by following this
documentation.
The HIT software automates most of the tasks necessary for the
software or hardware upgrade. The HIT softwareand the instructions
are included in this manual. It is recommended that the HIT User's
Manual is gone throughbefore starting the program.
When using the HIT for upgrading BSC, these instructions should
be followed for a more detailed description ofthe different phases,
which take place during the upgrade. The upgrade macro menu dialog
is designed to followclosely this document.
NOTE: The commands executed by the HIT macro do not always match
exactly with the commands presented inthe manual. This is because
sometimes the automated tasks of the HIT macro require more
commands anddifferent command syntaxes, than are presented in the
manual.
When using the HIT, the MML commands are executed automatically.
It is not necessary to type any commandsuntil it is specifically
requested by HIT.
3.2 Upgrade macro
3.2.1 Structure
All the SW & HW macros are gathered under one main macro
(UPGMAIN.HIT), from which the wanted SW / HWupgrade can be
selected. Regardless of which macro (SW or HW upgrade) is wanted to
run, the user alwaysstarts with the same main macro.Example of
macro structure:
UPGMAIN.HITo Select wanted upgrade:
SOFTWARE UPGRADES
x SW upgrade S15 -> S16
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.49
(120)
x
HARDWARE UPGRADES
x HW upgrade 1
x HW upgrade 2
x
Under each upgrade / tool there is a upgrade specific menu which
describes the steps which can be executedindividually:
SW upgrade S15 -> S16 (selected from main menu)o Select
wanted step
Make fallback
Check Firmware
Make pre-check
Copy SW
When a step is completed successfully, the user is brought back
to upgrade menu and a Done. -sign will appearat beginning of the
name of the step. If step execution fails for some reason, macro
stops and user can correctthe error manually and then continue
macro execution normally.
If macro or computer freezes totally during step execution and
macro needs to be restarted, user cannot re-runthe incomplete step
from the menu. In this case, the user must complete that certain
step manually, using thisdocumentation as guide. When the step has
been completed manually, user can continue the macro executionfrom
next available step. Note, that in the upgrade menu, there will be
Man. sign instead of Done. sign atbeginning of name of the manually
executed step.
Note!Once, user enters from main menu to upgrade menu, only way
to get back to the main menu is to restartwhole macro.
3.2.2 Communication
The macro communicates with user by using the HIT Pop-up
windows.
- Asking the user to give information (e.g. paths, file names,
etc.) & other userselections.
- Error situations
- Manual execution steps (i.e. when macro expects user to do
some actionsmanually (e.g. copy some files, install new HW /cabling
etc.)
- Macro completion
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.410
(120)
3.2.3 Log files
The upgrade macro provides different log files, from where the
user can verify the executed steps in macro andthe success of the
different steps & commands executed in the macro. There are
three different kind ofinformation / log files:
- Log file from HIT Response window (.log)
x This log contains all the information of the macro execution
(each MMLcommand and the whole output of the macro execution)
x User can accept the default log-file name or specify a new
one. Macrogives following pop-up window for selection:
x Macro writes separate log files for following steps:
9 Configuration printout (PRE)
9 Firmware
9 Plug-in unit software upgrade
9 Safecopy
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.411
(120)
9 Transfer software to BSC
9 Configuration printout (PRE)
x The same information can be found from both from a main log
file andfrom these specified smaller log files.
- Log file from HIT Message window (Messages.log)
x The contents of the message window are saved after macro
execution.x Information about errors in macro execution
- Log print of HIT (TimeTable.log) This is a shorter description
of the execution ofthe macro, and the log contains information
about:
x Starting an execution step in macrox Execution status (Done).x
Completion of execution step in macro
If macro execution is stopped for some reason, the log files
still remain in the folder the user has specified. Whenmacro
execution is started again, the log writing is continued from the
end of existing log files. All previouslywritten log information
remains intact and nothing is overwritten.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.412
(120)
4 INTRODUCTION
The BSC/TCSM upgrade for SDH/Sonet equipment protection
procedure consists of the following tasks:
- Fallback copying of the current software
- BSC configuration printout (pre-check)
- SDH/Sonet equipment protection upgrade for combined TCSM3i
(the wholeTCSA cabinet at a time)
- SDH/Sonet equipment protection upgrade for combined TCSM3i
(the one STM-1/OC-3 at a time)
- Actions after upgrade and post conditions
o BSS Integrationo BSC configuration printout (post-check)
Fallback copying, BSC configuration printout tasks can be
executed during daytime.Actual upgrade is recommended to be
executed during night-time. This procedure can be done for
combinedTCSM3i cabinets.The user can choose the upgrade to be
performed as TCSA cabinet or STM-1/OC-3 at a time. Either way,
theupgrade is done for one STMU pair individually. In some STMU
cases, the upgrade may concern also ETIP orother STMU PCM areas. In
this case, the traffic must be moved from these units, interface(s)
must be removedbecause the plug-in unit needs to be deleted from
equipment database.The estimated time for HW upgrade depends on the
configuration of the BSC.The upgrade cannot be executed with
traffic and traffic needs to be re-hosted. During upgrade STMU(s)
unit willbe blocked and state changed to TE-EX or SE-NH.
Cartridge and functional unit positions in combined TCSM3i
cabinets:
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.413
(120)
There is a choice of several options how the GTIC-0 and GTIC-1
cartridges has been equipped before upgrade.The choices depend on
the PIU types and configurations, like following:
- Use only ETIP
- Use mixed ETIP and ETS2 in the cartridges
- Use ETS2 cards with 2 interfaces , two active + two
standby
- Use ETS2 cards with one interface, one active + one
standby
With this procedure also following possibility is to be added:-
Use ETS2 cards with hardware redundancy
Background:One STMU unit (that is, one ETS2 plug-in unit) has
four SETs in use in the default configuration and in the
otheralternative one STMU unit (that is, one ETS2 plug-in unit) has
two SETs in use. In optical interface redundancy,only even STMU
indexes are used; either four (by default) or eight (alternative)
in both cartridges (GTIC 0 andGTIC 1).In S12 and S13 releases only
transmission protection for STMU units is implemented. I.e. the
protection switchingis done by between two fibres connected to the
same ETS2 unit. The main disadvantage of the transmissionprotection
is that if e.g. unit computer fails, all the traffic handled by the
unit may be prevented until the unit isrestarted.Equipment
protection of SDH/SONET interfaces is introduced in S15. In case of
equipment protection workingand protection sections of the same
STM-1/OC-3 optical interface are located in different ETS2 plug-in
units.
FTRB 1
FTRB 3 FTRB 2
FTRB 0
PDFU 1PDFU-B
1
2
3
4
0
5
PDFU-B
PDFU 0
TC2C-A
TC2C 0
REAR SIDE
0
0
0
6
0
6
9
TCSA 0
06
CLA
C-B
CLA
Cx
6
3
GT4C-A
GTIC4
AIR GUIDE
6
GT4C-A
GTIC2
GT4C-A
GTIC3
TC2C-A
TC2C 1
TC2C-A
TC2C 4
TC2C-A
TC2C 5
TC2C-A
TC2C 2
TC2C-A
TC2C 3
CPGO
8
FTRB 1
FTRB 3 FTRB 2
FTRB 0
PDFU 1PDFU-B
1
2
3
4
0
5
PDFU-B
PDFU 0
TC2C-A
TC2C 6
REAR SIDE
0
0
0
6
0
6
9
TCSA 1
06
CLA
C-B
CLA
C2
6
3
GT4C-A
GTIC7
AIR GUIDE
6
GT4C-A
GTIC5
GT4C-A
GTIC6
TC2C-A
TC2C 7
TC2C-A
TC2C 10
TC2C-A
TC2C 11
TC2C-A
TC2C 8
TC2C-A
TC2C 9
CPGO
8
FTRB 1
FTRB 3 FTRB 2
FTRB 0
PDFU 1PDFU-B
1
2
3
4
0
5
PDFU-B
PDFU 0
TC2C-A
TC2C 12
REAR SIDE
0
0
0
6
0
6
9
TCSA 2
06
CLA
C-B
CLA
C3
6
3
GT4C-A
GTIC10
AIR GUIDE
6
GT4C-A
GTIC8
GT4C-A
GTIC9
TC2C-A
TC2C 13
TC2C-A
TC2C 16
TC2C-A
TC2C 17
TC2C-A
TC2C 14
TC2C-A
TC2C 15
CPGO
8
x = 1 when BSC3i part isBSC3i 1000 or Flexi BSCx = 2 when BSC3i
part isBSC3i 2000
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.414
(120)
Full capacity means that four ETS2 plug-in units are equipped to
both GTIC cartridges (GTIC cartridges poweredby different PDFU-Bs)
and both STM-1/OC-3 interfaces (two active and two standby SET(s)
per STM-1/OC-3interface) of ETS2 plug-in units are in use.STMU
indexes before redundancy upgrade are following:STMU(s) in GTIC-0:
0 & 2 & 4 & 6STMU(s) in GTIC-1: 16 & 18 & 20
& 22
When HW redundancy upgrade is done for all ETS2 units, four new
ETS2 plug-in unitsmust be added for both GTIC-0 and GTIC-1 to gain
same capacity as in the originalconfiguration.
Half capacity means that eight ETS2 plug-in units are equipped
to both GTIC cartridges (GTIC cartridgespowered by different
PDFU-Bs) and only the first one of the STM-1/OC-3 interfaces
(active SET + standby SET)of ETS2 plug-in units are in use. This
configuration can be used only in BSC3i 1000/2000 or upgraded
FlexiBSC.
STMU indexes before redundancy upgrade are following:STMU(s) in
GTIC-0: 0 & 2 & 4 & 6 & 8 & 10 & 12 &
14STMU(s) in GTIC-1: 16 & 18 & 20 & 22 & 24 &
26 & 28 & 30
When HW redundancy upgrade is done for all ETS2 units, if same
capacity as in the original configuration iswanted, the second
interface of the ETS2 plug-in unit must be taken in use.
4.1 Combined TCSM3i equipment before upgrade
4.1.1 TCSA-0 cabinet
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.415
(120)
4.1.2 TCSA-1 cabinet
4.1.3 TCSA-2 cabinet
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.416
(120)
4.2 Combined TCSM3i equipment after upgrade
4.2.1 TCSA-0 cabinet
4.2.2 TCSA-1 cabinet
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.417
(120)
4.2.3 TCSA-2 cabinet
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.418
(120)
5 PRE-REQUIREMENTS
5.1 Pre-requirements & Actions needed prior upgrade
The procedure can be implemented for S16 software onwards. It is
recommended to install all available changedeliveries prior to the
upgrade.IMPORTANT!Re-direct traffic from upgraded TCSA cabinet or
STM-1/OC-3 before actual upgrade. Each STMU unitmust be handled
case by case and PCM areas which are affected during upgrade may
vary. It is possiblethat new protected STMU unit uses some other
STMU unit area or in case of mixed configuration theGTIC-1
cartridges track may contain ETIP plug-in units. In this case
effected units traffic needs to be re-directed, interfaces removed
and unit needs to be deleted (PCM areas released to new STMU unit
usage)from hardware database before new configuration is
created.BSS Split tool offers automated process to support BSC
renewal. This is extremely useful, when older BSC(s) aremodernised
to BSC3i(s). This process includes the automation of
labor-intensive re-hosting of BTS to new BSC(s)including data and
parameter updates to name a few. The downtime of operational BTS(s)
is this way minimisedduring re-homing. If re-homing speed is the
key driver, more than 100 sites can be moved to the new BSC
duringone night by using .XML files for data transfer between the
BSC(s) assisted by CM tools (CM Plan Manager, CMEditor and CM
Analyser). Further information about BSS Split tools is available
from Nokia OSS / NetActrepresentatives.
IMPORTANT!
When operating in Flexi BSC, make sure that OCTFIL parameter
SEL_OCTFIL_VARIANT_TO (class 2,parameter 1554) value is
correct:
Upgraded Flexi BSC 3000/4200 0000Initial Flexi BSC 3000/4200
0001
If OCTFIL value is incorrect, it may cause upgrade procedure to
work wrongly. The OCTFIL information is one ofthe input information
which macro uses (when macro is started) for analyse the used BSC
type. When value isincorrect for some reason, the macro may execute
the wrong steps during procedure execution.
5.2 Restrictions
STMU unit (ETS2 plug-in unit) which is to be upgraded can handle
following interfaces:x A interface (including A-SIGTRAN)
When STMU unit protection is changed, the unit will be blocked,
meaning that the interfaces which controlling unitis upgraded will
be affected. Macro informs user about affected PCM areas (and units
handling that area) which
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.419
(120)
are needed to be deleted. After the HW redundancy upgrade has
been finished successfully for one STMU unitpair, the traffic can
be re-directed back to old STMU unit.In case of upgrade to whole
TCSA cabinet, the traffic must be re-directed while upgrading and
after successfulupgrade, the traffic can be re-hosted back to that
same TCSA cabinet.Always, all the existing STMU units need to be
upgraded at once. Macro starts from first STMU index and keepsgoing
until every STMU unit has been upgraded. It is not allowed to use
both line protected and HW protectedSTMU units in same
GTIC-cartridge.
5.3 Needed documentation
To perform the upgrade successfully, the following documentation
is required:x BSC/TCSM upgrade for SDH/Sonet equipment protection
(this document)x Creating and managing BSC hardware (NED)x Cabling
Instructions for BSC3i (NED)x Equipment list for BSC3i (NED)x
Pre-Processor Program Informationx Fallback copying instructions of
DX200 BSC (NED)x Technical Support Note: Minimum HW Requirements
for BSC S1xx Releasex HIT Users manualx Cabling Instructions for
i-series Network Elements DN0094395x Labels of the IC209-A/IC209-B
Equipment Cabinet CAN104723
5.4 Needed equipment
To perform the upgrade successfully, the following HW are
required:x PC with installed HIT and upgrading macrosx Cabinet
Upgrade Set (ETS2/ETIP equipment protection TCSM/BSC3i/FlexiBSC)
for
upgrading Transmission protection to HW protection. Note that
the upgrade set is for
one TCSA cabinet in combined BSC/TCSM installation. So 3 peaces
are needed for
3 x TCSA cabinets (TCSA 0 & 1 & 2).
x Needed amount of ETS2 plug-in units. Note! In case of STMU
full configuration,same amount of ETS2 plug-in units needs to be
added to gain same capacity as in
the original configuration.
x S14 TCSM3i: HW redundancy: 5000871 ETS2/ETIP equipment
protection TCSMx S15 TCSM3i : HW redundancy: 5000888 Equipment
Protection Cabling TCSM
(S15)
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.420
(120)
5.5 HIT and upgrade macros
5.5.1 System requirements for HIT
HIT 3.4-0 swup is designed to operate on Windows and Linux.The
HIT installation requires approximately 20MB disk space, of which
the documentation occupies approximately5MB.
5.5.2 Installing HIT
It is necessary to go through this section only if the HIT
release 3.4-0 swup has not been installed. If the softwarehas
already been installed, proceed to the next section: Installing HIT
upgrading macros.
HIT release 3.4-0 swup is delivered in Release Binder found from
NOLS (Nokia Online Services). The installationof the software is
done by executing the SETUP.EXE -program and following the
instructions of the installationprogram.
5.5.3 Installing HIT upgrading macros
After the HIT program has been installed, it is necessary to
install the upgrading macros. The upgrading macrosare included in
the Release Binder which can be found from NOLS (Nokia Online
Services). Release bindercontains all the macros used in different
upgrades related to SW.
To install the macros into PC, execute the macros.exe program.
When the exe file is run the following dialog willappear:
Specify the folder to which the macros will be installed, press
Unzip and the macros will be installed.This zipped executable file
includes the whole upgrade macro and the needed directory
structure. The only userexecutable file, UPGMAIN.HIT, is extracted
to root directory of macro folder.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.421
(120)
5.5.4 HIT settings
Before running HIT, it is recommended that the 'use of FIFO
buffers' be turned off from the used communicationsport. This needs
to be done, because some PCs communications port handling is
unreliable with this settingactive.It is recommended that you
contact your local PC support for instructions on how to turn off
the use of FIFObuffers.If you are familiar with the settings of the
PC, here's an example of how to turn the use of FIFO buffers off.
InWindows 2000, the use of FIFO buffers is turned off in the
following way:
1. Start Control Panel
2. From Control Panel select System
3. In the System Properties dialog select Hardware/Device
Manager
4. In Device Manager select desired communications port (usually
COM1) anddouble-click it
5. In Communications Port (COMx) Properties dialog select Port
Settings
6. In Port Settings select Advanced
7. In Advanced Port Settings dialog deactivate the 'Use FIFO
buffers' and pressOK
8. Close all the opened dialogs by pressing OK
When opening the HIT program the first time, remember to
check/create the used device (ref. Hitguide.doc). It isrecommended
to use the network element name for the devices.
5.5.5 Connection settings
When opening the HIT program the first time, remember to
check/create the used devices (ref. Hitguide.doc).When the macro is
started, the available devices are listed to select device to be
connected.
Following connection types are supported:x Local connection
(COM)x Telnetx SSHx Via Netact (SSH)
5.5.5.1 Connection settings for Windows1.1.1.1.1 5.5.5.1.1
Configuration example for creating Telnet / SSH / NetAct
connection
Select Device > Set Configuration from menu.Following window
appears
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.422
(120)
Select New
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.423
(120)
Give name for connection and IP address of OMU or NetAct
server.
Note!DX_TELNET is selected for telnet connection and SSH is
selected for SSH connection inType/Protocol: field. Default port
for telnet is 23 and for SSH is 22.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.424
(120)
In case of Telnet or SSH connection option, select Login,Q/A
sheet and define the username and password ofBSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.425
(120)
In case of NetAct via SSH connection option, select Login sheet
and define the username and password ofNetAct communication server
and BSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.426
(120)
Select Terminal sheet and define the MML log file.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.427
(120)
If connection type is Telnet, press OK.
In SSH connection, define also settings of SSH sheet.Define
security level to medium or low level.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.428
(120)
After defining SSH related parameters, Press OK.
1.1.1.1.2 5.5.5.1.2 Configuration example for creating COM
connection
Select Device > Set Configuration from menu.Following window
appears
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.429
(120)
Note! COM connection is selectedSelect Login,Q/A sheet and
define the username and password of BSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.430
(120)
Select Terminal sheet and define the MML log file.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.431
(120)
Press OK.
5.5.5.2 Connection settings for Linux1.1.1.1.3 5.5.5.2.1
Configuration example for creating Telnet / SSH / NetAct
connection
Select Edit> Devices > from menuFollowing window
appears
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.432
(120)
Select New
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.433
(120)
Give name for connection and IP address of OMU or Net Act
server.
Note! DX_TELNET is selected for telnet connection and SSH is
selected for SSH connection inType/Protocol: field. Default port
for telnet is 23 and for SSH is 22.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.434
(120)
In case of Telnet or SSH connection option, select Login,Q/A
sheet and define the username and password ofBSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.435
(120)
In case of NetAct via SSH connection option, select Login sheet
and define the username and password ofNetAct communication server
and BSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.436
(120)
Select Terminal sheet and define the MML log file.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.437
(120)
If connection type is Telnet, press OK.
In SSH connection, define also settings of SSH sheet. Define
security level to medium or low level.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.438
(120)
After defining SSH related parameters, Press OK.1.1.1.1.4
5.5.5.2.2 Configuration example for creating COM connection
Select Edit> Devices > from menuFollowing window
appears
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.439
(120)
Note! COM connection is selectedSelect Login,Q/A sheet and
define the username and password of BSC MML session.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.440
(120)
Select Terminal sheet and define the MML log file.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.441
(120)
Press OK.
5.5.6 Starting the HIT application / macro execution
First of all, close List and Macro windows, as those are not
needed. In Response window all MML commands areprinted out. It is
recommended to keep Messages window as big as possible to able to
follow up the macroexecution. The important information is printed
out to the messages window.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.442
(120)
Open file UPGMAIN.HIT from the location it was extracted and
press Green Arrow to start the execution.
At the beginning, the main menu is shown and macro prompts user
to choose which upgrade toexecute. Clicking CANCEL in main menu
aborts the macro execution.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.443
(120)
The macro informs about the chosen procedure with following
pop-up window:
Select ini file from the list.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.444
(120)
Select target network element from the list.
User may choose the location where the macro log files should be
saved.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.445
(120)
Also, user can define whether to use default log file name or
define own.
The status of the current BSC software package is checked. Note
that the current software packagemust be with status BU before the
actual upgrade can be started. The software status is to bechecked
with command:
ZWQO:RUN;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.446
(120)
Check from the output that all the computer units which are
currently in use are running on correctsoftware package with the
status BU. If the software package status is FB or NW, find out the
causefor the setting.
If the status of the package is something else than BU, macro
gives following pop-up window:
The status can be changed to BU with command:
ZWSC:STAT=NW:STAT=BU;
The active and blocked alarms (DX200 and BTS alarms) can be
printed out with followingcommands:
ZAHO;ZABO;ZEOL;ZEOE;
Alarm printings can be skipped and macro asks user about the
wanted action with following pop-up:
Some environment information (status) is checked with following
commands:ZQRI;ZIWQ:,OMU:WS=0,;ZDCD;ZUSI:ALL;ZWTI:P:OMU;ZUSI:BCSU;ZWTI:P:GSW,0;ZYE?
This information is gathered for BSC type analysis.
IMPORTANT!If MML session is needed during upgrade, open another
MML connection than specified for the upgradeexecution. The same
MML connection usage for interrogate or modification purposes may
confuse the macroexecution.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.447
(120)
The procedure dialog is divided in main chapters, which may also
contain sub-chapters. Chapters and their sub-chapters correspond
directly to the document. Select the chapter to run and press
OK.Note!In order to complete upgrade successfully, the chapters and
steps must be executed in ascending order.
Select a step to run and press OK.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.448
(120)
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.449
(120)
6 FALLBACK COPYING OF THE CURRENT PACKAGE
A fallback copying of the running software package must be made
before the upgrade.A fallback copying from the old SW can be made
by running macro step Fallback copying of the
currentpackage.Manually, the fallback copying can be made following
the document: Fallback copying in BSC. The documentcan be found
from NED.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.450
(120)
7 BSC CONFIGURATION PRINTOUT (PRE-CHECK)
The information about the BSC configurations and conditions are
collected.Precondition checking is recommended to do during the
daytime before the actual upgrade will be started. Thechecking can
be made by using the macro (UPGMAIN.HIT) or manually following the
instructions from BSCconfiguration printout-document delivered in
Release Binder.For macro execution, choose the BSC configuration
printout (pre) step in BSC/TCSM upgrade for SDH/Sonetequipment
protection procedure. Follow then the macro execution according the
BSC configuration printout document.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.451
(120)
8 SDH/SONET EQUIPMENT PROTECTION UPGRADE FOR COMBINEDTCSM3I
(OFFLINE)
In this chapter, the upgrade will be done to whole TCSA cabinet
at a time (OFFLINE)sothat the cabinet cannot be handle traffic
during upgrade.
HW redundant STMU units will be equipped according to following
pictures.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.452
(120)
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.453
(120)
8.1 Choose TCSA cabinet to be upgraded
TCSA-0 cabinet must be upgrade first. TCSA-1 cabinet must be
upgrade second. TCSA-2 cabinet must beupgrade third.
Choose a correct TCSA cabinet which STMU units will be upgraded.
Upgrade must be made for whole TCSAcabinet at once.
8.2 Move traffic from STMU which will be upgraded
Move traffic from STMU units located in TCSA cabinet to be
upgraded.
Change TCSM units to SE-NH state located in TCSA cabinet to be
upgraded.
8.3 Delete old configurations & equipment
In this step, all the old STMU configurations and equipment will
be deleted.
Delete all STMU interface(s) located in chosen
TCSA-cabinet.Change STMU unit which are going to be upgraded (in
both cartridges ifexists) to SE-NH state.
ZUSC:STMU,:BL;ZUSC:STMU,:TE;ZUSC:STMU,:SE;ZUSC:STMU,:SE;
Transmission protection groups can be checked with following
command:ZYWI;
Delete existing transmission protection groups from all
STMU(s).
ZYWD:;
Remove through connected channel (manually):ZWGR::;
Delete transcoder PCM (manually):ZWGD: :,;
Set number of through connected channels (manually):ZWGS::0;
Disconnect TCSM units (manually):ZWUD:TCSM,:TR3E,;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.454
(120)
Delete ET equipment related to STMU unit(s).Disconnect ET
unit(s)
ZWUD:ET,&&:ETS2,0;
Delete plug-in unitsZWTQ:ET,&&:ETS2,0;
Delete unitsZWTV:ET,&&;
Delete STMU equipment with following
commands:ZWUD:STMU,:ETS2,0;ZWTQ:STMU,:ETS2,0;ZWTV:STMU,;
8.4 Install redundant ETS2 plug-in unit(s)
Install ETS2 plug-in unit(s) into track 7 for HW protection
usage if unit does not exist. One ETS2 plug-in unit mustexists in
same track in both GTIC-cartridges.
8.5 Make cabling changes and install new cables
Change spare MCMU state to
SE-NH.ZUSC:MCMU,,TE-EX;ZUSC:MCMU,,SE-OU;ZUSC:MCMU,,SE-NH;
Make cabling and setting modules changes according to Appendix1:
Combined TCSM3i cablings.
After cabling changes has been finished to first MCMU, change
the unit back to SP-EX, make a switchover andchange other MCMU to
SE-NH state. After second MCMU cabling changes, raise MCMU back to
working state.
8.6 New configuration & equipment with HW protection
In this chapter, all the equipment commands for creating HW
redundant STMU unit with corresponding ET unitsare given. In case
of manual execution, choose the correct STMU index to be equipped
according the picturepresented in chapter 9.1.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.455
(120)
8.6.1 BSC3i 1000/2000 or upgraded Flexi BSC
8.6.1.1 Equip new redundant STMU units
Create redundant STMU unit(s) for correct TCSA cabinet
TCSA-0
ZWTU:STMU,32:;ZWTU:STMU,34: ;ZWTU:STMU,36: ;
ZWTU:STMU,33: ;ZWTU:STMU,35: ;ZWTU:STMU,37: ;
TCSA-1
ZWTU:STMU,38: ;ZWTU:STMU,40: ;ZWTU:STMU,42: ;
ZWTU:STMU,39: ;ZWTU:STMU,41: ;ZWTU:STMU,43: ;
TCSA-2
ZWTU:STMU,44: ;ZWTU:STMU,46: ;ZWTU:STMU,48: ;
ZWTU:STMU,45: ;ZWTU:STMU,47: ;ZWTU:STMU,49: ;
Create redundant ETS2 plug-in unit
TCSA-0
For BSC 3i 1000/2000
ZWTP:STMU,32:ETS2,0,5::LAPD,8,882,TSL,0&&15;ZWTP:STMU,34:ETS2,0,6::LAPD,8,882,TSL,16&&31;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.456
(120)
ZWTP:STMU,36:ETS2,0,7::LAPD,8,883,TSL,0&&15;
ZWTP:STMU,33:ETS2,0,5::LAPD,8,890,TSL,0&&15;ZWTP:STMU,35:ETS2,0,6::LAPD,8,890,TSL,16&&31;ZWTP:STMU,37:ETS2,0,7::LAPD,8,891,TSL,0&&15;
For Upgraded Flexi BSC
ZWTP:STMU,32:ETS2,0,5::LAPD,8,1586,TSL,0&&15;ZWTP:STMU,34:ETS2,0,6::LAPD,8,1586,TSL,16&&31;ZWTP:STMU,36:ETS2,0,7::LAPD,8,1587,TSL,0&&15;
ZWTP:STMU,33:ETS2,0,5::LAPD,8,1594,TSL,0&&15;ZWTP:STMU,35:ETS2,0,6::LAPD,8,1594,TSL,16&&31;ZWTP:STMU,37:ETS2,0,7::LAPD,8,1595,TSL,0&&15;
TCSA-1
For BSC 3i 1000/2000
ZWTP:STMU,38:ETS2,0,5::LAPD,8,1074,TSL,0&&15;ZWTP:STMU,40:ETS2,0,6::LAPD,8,1074,TSL,16&&31;ZWTP:STMU,42:ETS2,0,7::LAPD,8,1075,TSL,0&&15;
ZWTP:STMU,39:ETS2,0,5::LAPD,8,1082,TSL,0&&15;ZWTP:STMU,41:ETS2,0,6::LAPD,8,1082TSL,16&&31;ZWTP:STMU,43:ETS2,0,7::LAPD,8,1083,TSL,0&&15;
For Upgraded Flexi BSC
ZWTP:STMU,38:ETS2,0,5::LAPD,8,882,TSL,0&&15;ZWTP:STMU,40:ETS2,0,6::LAPD,8,882,TSL,16&&31;ZWTP:STMU,42:ETS2,0,7::LAPD,8,883,TSL,0&&15;
ZWTP:STMU,39:ETS2,0,5::LAPD,8,890,TSL,0&&15;ZWTP:STMU,41:ETS2,0,6::LAPD,8,890,TSL,16&&31;ZWTP:STMU,43:ETS2,0,7::LAPD,8,891,TSL,0&&15;
TCSA-2 For BSC 3i 1000/2000,Upgraded Flexi BSC
ZWTP:STMU,44:ETS2,0,5::LAPD,8,1202,TSL,0&&15;ZWTP:STMU,46:ETS2,0,6::LAPD,8,1202,TSL,16&&31;ZWTP:STMU,48:ETS2,0,7::LAPD,8,1203,TSL,0&&15;
ZWTP:STMU,45:ETS2,0,5::LAPD,8,1210,TSL,0&&15;ZWTP:STMU,47:ETS2,0,6::LAPD,8,1210,TSL,16&&31;ZWTP:STMU,49:ETS2,0,7::LAPD,8,1211,TSL,0&&15;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.457
(120)
Connect ETS2 plug-in unit
TCSA-0
ZWUC:STMU,32:ETS2,0::BCSU,;ZWUC:STMU,34:ETS2,0::BCSU,;ZWUC:STMU,36:ETS2,0::BCSU,;
ZWUC:STMU,33:ETS2,0::BCSU,;ZWUC:STMU,35:ETS2,0::BCSU,;ZWUC:STMU,37:ETS2,0::BCSU,;
TCSA-1
ZWUC:STMU,38:ETS2,0::BCSU,;ZWUC:STMU,40:ETS2,0::BCSU,;ZWUC:STMU,42:ETS2,0::BCSU,;
ZWUC:STMU,39:ETS2,0::BCSU,;ZWUC:STMU,41:ETS2,0::BCSU,;ZWUC:STMU,43:ETS2,0::BCSU,;
TCSA-2
ZWUC:STMU,44:ETS2,0::BCSU,;ZWUC:STMU,46:ETS2,0::BCSU,;ZWUC:STMU,48:ETS2,0::BCSU,;
ZWUC:STMU,45:ETS2,0::BCSU,;ZWUC:STMU,47:ETS2,0::BCSU,;ZWUC:STMU,49:ETS2,0::BCSU,;
8.6.1.2 Create new ET units
Create ET plug-in units for ANSI or ETSI mode.
ETSI
TCSA-0
ZWTU:ET,3560&&3622:< LOCATION
>:UNIT=STMU,IND=32,IF=0;ZWTU:ET,3624&&3686: <
LOCATION >:UNIT=STMU,IND=32,IF=1;
ZWTU:ET,3688&&3750: < LOCATION
>:UNIT=STMU,IND=34,IF=0;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.458
(120)
ZWTU:ET,3752&&3814: < LOCATION >:UNIT=STMU,IND
=34,IF=1;
ZWTU:ET,3816&&3878: < LOCATION >:UNIT=STMU,IND
=36,IF=0;ZWTU:ET,3880&&3942::UNIT=STMU,IND=36,IF=1;
ZWTP:ET,3560&&3622:ETS2,0,5::ETT00,8,3560&&3622,TSL,0:;ZWTP:ET,3624&&3686:ETS2,0,5::ETT00,8,3624&&3686,TSL,0:;
ZWTP:ET,3688&&3750:ETS2,0,6::ETT00,8,3688&&3750,TSL,0:;ZWTP:ET,3752&&3814:ETS2,0,6::ETT00,8,3752&&3814,TSL,0:;
ZWTP:ET,3816&&3878:ETS2,0,7::ETT00,8,3816&&3878,TSL,0:;ZWTP:ET,3880&&3942:ETS2,0,7::ETT00,8,3880&&3942,TSL,0:;
TCSA-1ZWTU:ET,3944&&4006::UNIT=STMU,IND=38,IF=0;ZWTU:ET,4008&&4070::UNIT=STMU,IND=38,IF=1;
ZWTU:ET,4072&&4134::UNIT=STMU,IND=40,IF=0;ZWTU:ET,4136&&4198::UNIT=STMU,IND=40,IF=1;
ZWTU:ET,4200&&4262::UNIT=STMU,IND=42,IF=0;ZWTU:ET,4264&&4326::UNIT=STMU,IND=42,IF=1;
ZWTP:ET,3944&&4006:ETS2,0,5::ETT00,8,3944&&4006,TSL,0:;ZWTP:ET,4008&&4070:ETS2,0,5::ETT00,8,4008&&4070,TSL,0:;
ZWTP:ET,4072&&4134:ETS2,0,6::ETT00,8,4072&&4134,TSL,0:;ZWTP:ET,4136&&4198:ETS2,0,6::ETT00,8,4136&&4198,TSL,0:;
ZWTP:ET,4200&&4262:ETS2,0,7::ETT00,8,4200&&4262,TSL,0:;ZWTP:ET,4264&&4326:ETS2,0,7::ETT00,8,4264&&4326,TSL,0:;
TCSA-2ZWTU:ET,4328&&4390::UNIT=STMU,IND=44,IF=0;ZWTU:ET,4392&&4454::UNIT=STMU,IND=44,IF=1;
ZWTU:ET,4456&&4518::UNIT=STMU,IND=46,IF=0;ZWTU:ET,4520&&4582::UNIT=STMU,IND=46,IF=1;
ZWTU:ET,4584&&4646::UNIT=STMU,IND=48,IF=0;ZWTU:ET,4648&&4710::UNIT=STMU,IND=48,IF=1;
ZWTP:ET,4328&&4390:ETS2,0,5::ETT00,8,4328&&4390,TSL,0:;ZWTP:ET,4392&&4454:ETS2,0,5::ETT00,8,4392&&4454,TSL,0:;
ZWTP:ET,4456&&4518:ETS2,0,6::ETT00,8,4456&&4518,TSL,0:;ZWTP:ET,4520&&4582:ETS2,0,6::ETT00,8,4520&&4582,TSL,0:;
ZWTP:ET,4584&&4646:ETS2,0,7::ETT00,8,4584&&4646,TSL,0:;ZWTP:ET,4648&&4710:ETS2,0,7::ETT00,8,4648&&4710,TSL,0:;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.459
(120)
ANSI
TCSA-0ZWTU:ET,3560&&3643::UNIT=STMU,IND=32,IF=0;ZWTU:ET,3644&&3727::UNIT=STMU,IND=32,IF=1;
ZWTU:ET,3728&&3811::UNIT=STMU,IND=34,IF=0;ZWTU:ET,3812&&3895::UNIT=STMU,IND=34,IF=1;
ZWTU:ET,3896&&3979::UNIT=STMU,IND=36,IF=0;ZWTU:ET,3980&&4063::UNIT=STMU,IND=36,IF=1;
ZWTP:ET,3560&&3643:ETS2,0,5::ETT00,8,3560&&3643,TSL,0:;ZWTP:ET,3644&&3727:ETS2,0,5::ETT00,8,3644&&3727,TSL,0:;
ZWTP:ET,3728&&3811:ETS2,0,6::ETT00,8,3728&&3811,TSL,0:;ZWTP:ET,3812&&3895:ETS2,0,6::ETT00,8,3812&&3895,TSL,0:;
ZWTP:ET,3896&&3979:ETS2,0,7::ETT00,8,3896&&3979,TSL,0:;ZWTP:ET,3980&&4063:ETS2,0,7::ETT00,8,3980&&4063,TSL,0:;
TCSA-1ZWTU:ET,4064&&4147::UNIT=STMU,IND=38,IF=0;ZWTU:ET,4148&&4231::UNIT=STMU,IND=38,IF=1;
ZWTU:ET,4232&&4315::UNIT=STMU,IND=40,IF=0;ZWTU:ET,4316&&4399::UNIT=STMU,IND=40,IF=1;
ZWTU:ET,4400&&4483::UNIT=STMU,IND=42,IF=0;ZWTU:ET,4484&&4567::UNIT=STMU,IND=42,IF=1;
ZWTP:ET,4064&&4147:ETS2,0,5::ETT00,8,4064&&4147,TSL,0:;ZWTP:ET,4148&&4231:ETS2,0,5::ETT00,8,4148&&4231,TSL,0:;
ZWTP:ET,4232&&4315:ETS2,0,6::ETT00,8,4232&&4315,TSL,0:;ZWTP:ET,4316&&4399:ETS2,0,6::ETT00,8,4316&&4399,TSL,0:;
ZWTP:ET,4400&&4483:ETS2,0,7::ETT00,8,4400&&4483,TSL,0:;ZWTP:ET,4484&&4567:ETS2,0,7::ETT00,8,4484&&4567,TSL,0:;
TCSA-2ZWTU:ET,4568&&4651::UNIT=STMU,IND=44,IF=0;ZWTU:ET,4652&&4735::UNIT=STMU,IND=44,IF=1;
ZWTU:ET,4736&&4819::UNIT=STMU,IND=46,IF=0;ZWTU:ET,4820&&4903::UNIT=STMU,IND=46,IF=1;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.460
(120)
ZWTU:ET,4904&&4987::UNIT=STMU,IND=48,IF=0;ZWTU:ET,4988&&5071::UNIT=STMU,IND=48,IF=1;
ZWTP:ET,4568&&4651:ETS2,0,5::ETT00,8,4568&&4651,TSL,0:;ZWTP:ET,4652&&4735:ETS2,0,5::ETT00,8,4652&&4735,TSL,0:;
ZWTP:ET,4736&&4819:ETS2,0,6::ETT00,8,4736&&4819,TSL,0:;ZWTP:ET,4820&&4903:ETS2,0,6::ETT00,8,4820&&4903,TSL,0:;
ZWTP:ET,4904&&4987:ETS2,0,7::ETT00,8,4904&&4987,TSL,0:;ZWTP:ET,4988&&5071:ETS2,0,7::ETT00,8,4988&&5071,TSL,0:;
Connect ET plug-in units
ETSIZWUC:ET,3560&&3622:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3624&&3686:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3688&&3750:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3752&&3814:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3816&&3878:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3880&&3942:ETS2,0:IF=A:BCSU,:;
ZWUC:ET,3944&&4006:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4008&&4070:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4072&&4134:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4136&&4198:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4200&&4262:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4264&&4326:ETS2,0:IF=A:BCSU,:;
ZWUC:ET,4328&&4390:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4392&&4454:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4456&&4518:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4520&&4582:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4584&&4646:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4648&&4710:ETS2,0:IF=A:BCSU,:;
ANSIZWUC:ET,3560&&3643:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3644&&3727:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3728&&3811:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3812&&3895:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3896&&3979:ETS2,0:IF=A:BCSU,:;ZWUC:ET,3980&&4063:ETS2,0:IF=A:BCSU,:;
ZWUC:ET,4064&&4147:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4148&&4231:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4232&&4315:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4316&&4399:ETS2,0:IF=A:BCSU,:;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.461
(120)
ZWUC:ET,4400&&4483:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4484&&4567:ETS2,0:IF=A:BCSU,:;
ZWUC:ET,4568&&4651:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4652&&4735:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4736&&4819:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4820&&4903:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4904&&4987:ETS2,0:IF=A:BCSU,:;ZWUC:ET,4988&&5071:ETS2,0:IF=A:BCSU,:;
8.6.1.3 Create new HW protection sets
Create HW protection sets for ANSI or ETSI mode.
ANSI:
TCSA-0ZYWC:,,APS:128,132;ZYWC:,,APS:130,134;
ZYWC:,,APS:136,140;ZYWC:,,APS:138,142;
ZYWC:,,APS:144,148;ZYWC:,,APS:146,150;
TCSA-1ZYWC:,,APS:152,156;ZYWC:,,APS:154,158;
ZYWC:,,APS:160,164;ZYWC:,,APS:162,166;
ZYWC:,,APS:168,172;ZYWC:,,APS:170,174;
TCSA-2ZYWC:,,APS:176,180;ZYWC:,,APS:178,182;
ZYWC:,,APS:184,188;ZYWC:,,APS:186,190;
ZYWC:,,APS:192,196;ZYWC:,,APS:194,198;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.462
(120)
ETSI:
TCSA-0ZYWC:,,MSP:128,132;ZYWC:,,MSP:130,134;
ZYWC:,,MSP:136,140;ZYWC:,,MSP:138,142;
ZYWC:,,MSP:144,148;ZYWC:,,MSP:146,150;
TCSA-1ZYWC:,,MSP:152,156;ZYWC:,,MSP:154,158;
ZYWC:,,MSP:160,164;ZYWC:,,MSP:162,166;
ZYWC:,,MSP:168,172;ZYWC:,,MSP:170,174;
TCSA-2ZYWC:,,MSP:176,180;ZYWC:,,MSP:178,182;
ZYWC:,,MSP:184,188;ZYWC:,,MSP:186,190;
ZYWC:,,MSP:192,196;ZYWC:,,MSP:194,198;
8.6.1.4 Change new STMU units to WO-EX state
Change STMU(s) to WO-EX state
ZUSC:STMU,:SE;ZUSC:STMU,:TE;
Macro executes Plug-in unit software upgrade procedure for STMU
unit. After PIU software has been updatedsuccessfully,Run
diagnostic:
ZUDU:STMU,;After successful loading take the unit to WO-EX
state
ZUSC:STMU,:WO;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.463
(120)
Note!If more TCSA cabinets needs to be upgraded, do the chapters
8.1-8.6 again.
8.6.2 New Delivery Flexi BSC
8.6.2.1 Equip new redundant STMU units
Create redundant STMU unit(s) for correct TCSA cabinet
TCSA-0
ZWTU:STMU,32:1C1-3;ZWTU:STMU,34:1C1-3;ZWTU:STMU,36:1C1-3;
ZWTU:STMU,33:1C1-6;ZWTU:STMU,35:1C1-6;ZWTU:STMU,37:1C1-6;
TCSA-1
ZWTU:STMU,38:1C1-3;ZWTU:STMU,40:1C1-3;ZWTU:STMU,42:1C1-3;
ZWTU:STMU,39:1C1-6;ZWTU:STMU,41:1C1-6;ZWTU:STMU,43:1C1-6;
TCSA-2
ZWTU:STMU,44:1D1-3;ZWTU:STMU,46:1D1-3;ZWTU:STMU,48:1D1-3;
ZWTU:STMU,45:1D1-6;ZWTU:STMU,47:1D1-6;ZWTU:STMU,49:1D1-6;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.464
(120)
Create redundant ETS2 plug-in unit
TCSA-0
ZWTP:STMU,32:ETS2,0,5::LAPD,8,1714,TSL,0&&15;ZWTP:STMU,34:ETS2,0,6::LAPD,8,1714,TSL,16&&31;ZWTP:STMU,36:ETS2,0,7::LAPD,8,1715,TSL,0&&15;
ZWTP:STMU,33:ETS2,0,5::LAPD,8,1722,TSL,0&&15;ZWTP:STMU,35:ETS2,0,6::LAPD,8,1722,TSL,16&&31;ZWTP:STMU,37:ETS2,0,7::LAPD,8,1723,TSL,0&&15;
TCSA-1
ZWTP:STMU,38:ETS2,0,5::LAPD,8,1458,TSL,0&&15;ZWTP:STMU,40:ETS2,0,6::LAPD,8,1458,TSL,16&&31;ZWTP:STMU,42:ETS2,0,7::LAPD,8,1459,TSL,0&&15;
ZWTP:STMU,39:ETS2,0,5::LAPD,8,1466,TSL,0&&15;ZWTP:STMU,41:ETS2,0,6::LAPD,8,1466,TSL,16&&31;ZWTP:STMU,43:ETS2,0,7::LAPD,8,1467,TSL,0&&15;
TCSA-2
ZWTP:STMU,44:ETS2,0,5::LAPD,8,1202,TSL,0&&15;ZWTP:STMU,46:ETS2,0,6::LAPD,8,1202,TSL,16&&31;ZWTP:STMU,48:ETS2,0,7::LAPD,8,1203,TSL,0&&15;
ZWTP:STMU,45:ETS2,0,5::LAPD,8,1210,TSL,0&&15;ZWTP:STMU,47:ETS2,0,6::LAPD,8,1210,TSL,16&&31;ZWTP:STMU,49:ETS2,0,7::LAPD,8,1211,TSL,0&&15;
Connect ETS2 plug-in unit
TCSA-0
ZWUC:STMU,32:ETS2,0::BCSU,;ZWUC:STMU,34:ETS2,0::BCSU,;ZWUC:STMU,36:ETS2,0::BCSU,;
ZWUC:STMU,33:ETS2,0::BCSU,;ZWUC:STMU,35:ETS2,0::BCSU,;ZWUC:STMU,37:ETS2,0::BCSU,;
TCSA-1
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.465
(120)
ZWUC:STMU,38:ETS2,0::BCSU,;ZWUC:STMU,40:ETS2,0::BCSU,;ZWUC:STMU,42:ETS2,0::BCSU,;
ZWUC:STMU,39:ETS2,0::BCSU,;ZWUC:STMU,41:ETS2,0::BCSU,;ZWUC:STMU,43:ETS2,0::BCSU,;
TCSA-2
ZWUC:STMU,44:ETS2,0::BCSU,;ZWUC:STMU,46:ETS2,0::BCSU,;ZWUC:STMU,48:ETS2,0::BCSU,;
ZWUC:STMU,45:ETS2,0::BCSU,;ZWUC:STMU,47:ETS2,0::BCSU,;ZWUC:STMU,49:ETS2,0::BCSU,;
8.6.2.2 Create new ET units
Create ET plug-in units for ANSI or ETSI mode.
ETSI
TCSA-0ZWTU:ET,3560&&3622:STMU,32,IF=0;ZWTU:ET,3624&&3686:STMU,32,IF=1;
ZWTU:ET,3688&&3750:STMU,34,IF=0;ZWTU:ET,3752&&3814:STMU,34,IF=1;
ZWTU:ET,3816&&3878:STMU,36,IF=0;ZWTU:ET,3880&&3942:STMU,36,IF=1;
ZWTP:ET,3560&&3622:ETS2,0,5::ETT00,8,3560&&3622,TSL,0:;ZWTP:ET,3624&&3686:ETS2,0,5::ETT00,8,3624&&3686,TSL,0:;
ZWTP:ET,3688&&3750:ETS2,0,6::ETT00,8,3688&&3750,TSL,0:;ZWTP:ET,3752&&3814:ETS2,0,6::ETT00,8,3752&&3814,TSL,0:;
ZWTP:ET,3816&&3878:ETS2,0,7::ETT00,8,3816&&3878,TSL,0:;ZWTP:ET,3880&&3942:ETS2,0,7::ETT00,8,3880&&3942,TSL,0:;
TCSA-1ZWTU:ET,3944&&4006:STMU,38,IF=0;ZWTU:ET,4008&&4070:STMU,38,IF=1;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.466
(120)
ZWTU:ET,4072&&4134:STMU,40,IF=0;ZWTU:ET,4136&&4198:STMU,40,IF=1;
ZWTU:ET,4200&&4262:STMU,42,IF=0;ZWTU:ET,4264&&4326:STMU,42,IF=1;
ZWTP:ET,3944&&4006:ETS2,0,5::ETT00,8,3944&&4006,TSL,0:;ZWTP:ET,4008&&4070:ETS2,0,5::ETT00,8,4008&&4070,TSL,0:;
ZWTP:ET,4072&&4134:ETS2,0,6::ETT00,8,4072&&4134,TSL,0:;ZWTP:ET,4136&&4198:ETS2,0,6::ETT00,8,4136&&4198,TSL,0:;
ZWTP:ET,4200&&4262:ETS2,0,7::ETT00,8,4200&&4262,TSL,0:;ZWTP:ET,4264&&4326:ETS2,0,7::ETT00,8,4264&&4326,TSL,0:;
TCSA-2ZWTU:ET,4328&&4390:STMU,44,IF=0;ZWTU:ET,4392&&4454:STMU,44,IF=1;
ZWTU:ET,4456&&4518:STMU,46,IF=0;ZWTU:ET,4520&&4582:STMU,46,IF=1;
ZWTU:ET,4584&&4646:STMU,48,IF=0;ZWTU:ET,4648&&4710:STMU,48,IF=1;
ZWTP:ET,4328&&4390:ETS2,0,5::ETT00,8,4328&&4390,TSL,0:;ZWTP:ET,4392&&4454:ETS2,0,5::ETT00,8,4392&&4454,TSL,0:;
ZWTP:ET,4456&&4518:ETS2,0,6::ETT00,8,4456&&4518,TSL,0:;ZWTP:ET,4520&&4582:ETS2,0,6::ETT00,8,4520&&4582,TSL,0:;
ZWTP:ET,4584&&4646:ETS2,0,7::ETT00,8,4584&&4646,TSL,0:;ZWTP:ET,4648&&4710:ETS2,0,7::ETT00,8,4648&&4710,TSL,0:;
ANSI
TCSA-0ZWTU:ET,3560&&3643:STMU,32,IF=0;ZWTU:ET,3644&&3727:STMU,32,IF=1;
ZWTU:ET,3728&&3811:STMU,34,IF=0;ZWTU:ET,3812&&3895:STMU,34,IF=1;
ZWTU:ET,3896&&3979:STMU,36,IF=0;ZWTU:ET,3980&&4063:STMU,36,IF=1;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.467
(120)
ZWTP:ET,3560&&3643:ETS2,0,5::ETT00,8,3560&&3643,TSL,0:;ZWTP:ET,3644&&3727:ETS2,0,5::ETT00,8,3644&&3727,TSL,0:;
ZWTP:ET,3728&&3811:ETS2,0,6::ETT00,8,3728&&3811,TSL,0:;ZWTP:ET,3812&&3895:ETS2,0,6::ETT00,8,3812&&3895,TSL,0:;
ZWTP:ET,3896&&3979:ETS2,0,7::ETT00,8,3896&&3979,TSL,0:;ZWTP:ET,3980&&4063:ETS2,0,7::ETT00,8,3980&&4063,TSL,0:;
TCSA-1ZWTU:ET,4064&&4147:STMU,38,IF=0;ZWTU:ET,4148&&4231:STMU,38,IF=1;
ZWTU:ET,4232&&4315:STMU,40,IF=0;ZWTU:ET,4316&&4399:STMU,40,IF=1;
ZWTU:ET,4400&&4483:STMU,42,IF=0;ZWTU:ET,4484&&4567:STMU,42,IF=1;
ZWTP:ET,4064&&4147:ETS2,0,5::ETT00,8,4064&&4147,TSL,0:;ZWTP:ET,4148&&4231:ETS2,0,5::ETT00,8,4148&&4231,TSL,0:;
ZWTP:ET,4232&&4315:ETS2,0,6::ETT00,8,4232&&4315,TSL,0:;ZWTP:ET,4316&&4399:ETS2,0,6::ETT00,8,4316&&4399,TSL,0:;
ZWTP:ET,4400&&4483:ETS2,0,7::ETT00,8,4400&&4483,TSL,0:;ZWTP:ET,4484&&4567:ETS2,0,7::ETT00,8,4484&&4567,TSL,0:;
TCSA-2ZWTU:ET,4568&&4651:STMU,44,IF=0;ZWTU:ET,4652&&4735:STMU,44,IF=1;
ZWTU:ET,4736&&4819:STMU,46,IF=0;ZWTU:ET,4820&&4903:STMU,46,IF=1;
ZWTU:ET,4904&&4987:STMU,48,IF=0;ZWTU:ET,4988&&5071:STMU,48,IF=1;
ZWTP:ET,4568&&4651:ETS2,0,5::ETT00,8,4568&&4651,TSL,0:;ZWTP:ET,4652&&4735:ETS2,0,5::ETT00,8,4652&&4735,TSL,0:;
ZWTP:ET,4736&&4819:ETS2,0,6::ETT00,8,4736&&4819,TSL,0:;ZWTP:ET,4820&&4903:ETS2,0,6::ETT00,8,4820&&4903,TSL,0:;
ZWTP:ET,4904&&4987:ETS2,0,7::ETT00,8,4904&&4987,TSL,0:;ZWTP:ET,4988&&5071:ETS2,0,7::ETT00,8,4988&&5071,TSL,0:;
Connect ET plug-in units
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.468
(120)
ETSIZWUC:ET,3560&&3622:ETS2,0:IF=:BCSU,:;ZWUC:ET,3624&&3686:ETS2,0:IF=:BCSU,:;ZWUC:ET,3688&&3750:ETS2,0:IF=:BCSU,:;ZWUC:ET,3752&&3814:ETS2,0:IF=:BCSU,:;ZWUC:ET,3816&&3878:ETS2,0:IF=:BCSU,:;ZWUC:ET,3712&&3744:ETS2,0:IF=:BCSU,:;
ZWUC:ET,3944&&4006:ETS2,0:IF=:BCSU,:;ZWUC:ET,4008&&4070:ETS2,0:IF=:BCSU,:;ZWUC:ET,4072&&4134:ETS2,0:IF=:BCSU,:;ZWUC:ET,4136&&4198:ETS2,0:IF=:BCSU,:;ZWUC:ET,4200&&4262:ETS2,0:IF=:BCSU,:;ZWUC:ET,4264&&4326:ETS2,0:IF=:BCSU,:;
ZWUC:ET,4328&&4390:ETS2,0:IF=:BCSU,:;ZWUC:ET,4392&&4454:ETS2,0:IF=:BCSU,:;ZWUC:ET,4456&&4518:ETS2,0:IF=:BCSU,:;ZWUC:ET,4520&&4582:ETS2,0:IF=:BCSU,:;ZWUC:ET,4584&&4646:ETS2,0:IF=:BCSU,:;ZWUC:ET,4648&&4710:ETS2,0:IF=:BCSU,:;
ANSIZWUC:ET,3560&&3643:ETS2,0:IF=:BCSU,:;ZWUC:ET,3644&&3727:ETS2,0:IF=:BCSU,:;ZWUC:ET,3728&&3811:ETS2,0:IF=:BCSU,:;ZWUC:ET,3812&&3895:ETS2,0:IF=:BCSU,:;ZWUC:ET,3896&&3979:ETS2,0:IF=:BCSU,:;ZWUC:ET,3980&&4063:ETS2,0:IF=:BCSU,:;
ZWUC:ET,4064&&4147:ETS2,0:IF=:BCSU,:;ZWUC:ET,4148&&4231:ETS2,0:IF=:BCSU,:;ZWUC:ET,4232&&4315:ETS2,0:IF=:BCSU,:;ZWUC:ET,4316&&4399:ETS2,0:IF=:BCSU,:;ZWUC:ET,4400&&4483:ETS2,0:IF=:BCSU,:;ZWUC:ET,4484&&4567:ETS2,0:IF=:BCSU,:;
ZWUC:ET,4568&&4651:ETS2,0:IF=:BCSU,:;ZWUC:ET,4652&&4735:ETS2,0:IF=:BCSU,:;ZWUC:ET,4736&&4819:ETS2,0:IF=:BCSU,:;ZWUC:ET,4820&&4903:ETS2,0:IF=:BCSU,:;ZWUC:ET,4904&&4987:ETS2,0:IF=:BCSU,:;ZWUC:ET,4988&&5071:ETS2,0:IF=:BCSU,:;
8.6.2.3 Create new HW protection sets
Create HW protection sets for ANSI or ETSI mode.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.469
(120)
ANSI:
TCSA-0ZYWC:,,,APS:128,132;ZYWC:,,,APS:130,134;
ZYWC:,,,APS:136,140;ZYWC:,,,APS:138,142;
ZYWC:,,,APS:144,148;ZYWC:,,,APS:146,150;
TCSA-1ZYWC:,,,APS:152,156;ZYWC:,,,APS:154,158;
ZYWC:,,,APS:160,164;ZYWC:,,,APS:162,166;
ZYWC:,,,APS:168,172;ZYWC:,,,APS:170,174;
TCSA-2ZYWC:,,,APS:176,180;ZYWC:,,,APS:178,182;
ZYWC:,,,APS:184,188;ZYWC:,,,APS:186,190;
ZYWC:,,,APS:192,196;ZYWC:,,,APS:194,198;
ETSI:
TCSA-0ZYWC:,,,MSP:128,132;ZYWC:,,,MSP:130,134;
ZYWC:,,,MSP,140;ZYWC:,,,MSP:138,142;
ZYWC:,,,MSP:144,148;ZYWC:,,,MSP:146,150;
TCSA-1
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.470
(120)
ZYWC:,,,MSP:152,156;ZYWC:,,,MSP:154,158;
ZYWC:,,,MSP:160,164;ZYWC:,,,MSP:162,166;
ZYWC:,,,MSP:168,172;ZYWC:,,,MSP:170,174;
TCSA-2ZYWC:,,,MSP:176,180;ZYWC:,,,MSP:178,182;
ZYWC:,,,MSP:184,188;ZYWC:,,,MSP:186,190;
ZYWC:,,,MSP:192,196;ZYWC:,,,MSP:194,198;
8.6.2.4 Change new STMU units to WO-EX state
Change both GTIC cardridges STMU to WO-EX state
ZUSC:STMU,:SE;ZUSC:STMU,:TE;
Macro executes Plug-in unit software upgrade procedure for STMU
unit. After PIU software has been updatedsuccessfully,Run
diagnostic:
ZUDU:STMU,;After successful loading take the unit to WO-EX
state
ZUSC:STMU,:WO;
Note!If more TCSA cabinets needs to be upgraded, do the chapters
8.1-8.6 again.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.471
(120)
9 SDH/SONET EQUIPMENT PROTECTION UPGRADE FOR COMBINEDTCSM3I
(LIVE)
In this chapter, the upgrade will be done to one STM-1/OC-3 at a
time(LIVE) so thatduring upgrade, the effected SET cannot handle
traffic.
HW redundant STMU units will be equipped according to following
pictures.
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.472
(120)
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.473
(120)
9.1 TCSA-0
In this chapter TCSA-0 cabinets STMU units are upgraded serially
starting from STMU index 34. STMU-32 unitand related ET SET(s) are
not needed to be deleted and re-created. In this case only old
protection groups needsto be deleted.
9.1.1 Remove protection groups
Change sets 129, 131, 137, 145, 147 and 153 to SE-NH state with
following command:
ZUSC:SET,:TE,FCD:;ZUSC:SET.:SE;ZUSC:SET,:SE;
Remove protection groups from STMU-32/34/36/38 units with
following command:
ZYWD:;
9.1.2 Remove interfaces from SET-144 and disconnect effected
TCSM(s)
In this step, delete interfaces from SET-144 unit. Disconnect
also manually related TCSM(s). TCSM unit(s)equipment is not needed
to be deleted only disconnection is enough.
More instruction can be found from NED document Creating and
managing BSC configuration.
9.1.3 Change SET-144 to SE-NH state
Change SET-144 to SE-NH state with following
commandsZUSC:SET,144:TE,FCD:;ZUSC:SET,144:SE;ZUSC:SET,144:SE;
9.1.4 Delete SET-144
Delete SET-144 with following commands:
Disconnect unitsETSI
ZWUD:ET,3752&&3814:ETS2,0;
ANSIZWUD:ET,3812&&3895:ETS2,0;
-
DN09114099BSC3i/TCSM3iupgradeforSDH/Sonetequipmentprotection(S12S14TCSMHW)Copyright2013NokiaSolutionsandNetworks.Allrightsreserved.CONFIDENTIALAPPROVED1.474
(120)
Delete plug-in unitsETSI
ZWTQ:ET,3752&&3814:ETS2,0;
ANSIZWTQ:ET,3812&&3895:ETS2,0;
Delete unitsETSI
ZWTV:ET,3752&&3814;ANSI
ZWTV:ET