BSK System Fireplaces
Mar 15, 2016
BSK 06 - Plastered surface
BSKSystem Fireplaces
2
made in germany.a
BRUNNER is a traditional family business,
a leading manufacturer of wood stoves.
In our fireplaces we put all the knowledge
and experience as well as our own attitude
that made us wide known over the recent
decades — to offer the best of all fireboxes
that are currently available on the market.
With our BSK fireplace kits it is now possible
to buy a genuine BRUNNER fireplace insert
together with a complete set of cladding
materials.
3
BSK 03 - Plastered surfaceHeat screen with wave pattern & glossy fire table BSK 05 - Plastered surface
Contents Page
made in germany 2
BSK 01 4
BSK 02 8
BSK 03 12
BSK 04 16
BSK 05 20
BSK 06 24
BSK 07 28
BSK 08 32
Assembly 36
Plastered walls 37
Tile furnishing options 38
4
Eck-Kamin 57/52/52
BSK 01a
a BSK 01 lifting doora BSK 01 side-opening
5
BSK 01 - Plastered surface
Room-high.The cladding kit can be extended for even higher structures.
Provided on site:
Air intake at the bottom rear of fireplace.
Warm air outlet on back walls, 500 mm below the ceiling area.
Insulation of ceiling.
595
590
770
800
6
BSK 01 Fireplace:
57/52/52 corner lifting door
57/52/52 corner side-opening
Rated heating power kW 10 10
Wood consumption kg/h 3 3
Necessary supply pressure Pa 13 13
Flue gas mass flow g/s 12 12
Flue gas temperature behind steel hood
°C 210 210
Smoke outlet mm ø 200 ø 200
Required combustion air m3/h 30 30
Combustion air connection mm ø 125 ø 125
Cladding components:
Ground area (width x depth) mm 800 x 800 800 x 800
Overall height mm 1907 1902
Height extension ring mm 304 304
Wall thickness mm 30/35 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50 50
Distance to the ceiling mm 600 600
Insulation thickness for ceiling, with/without warm air grating
mm 120/160 120/160
Air intake opening area* cm2 800 800
Warm air outlet area for top cover plate
cm2 935 935
Total weight kg 599 524
Tested according to EN 13229 EN 13229
Dimensions & Technical Data.BSK 01a
* Air intake opening in bottom area must be provided on site.
Height extension ring(additional cladding part for even higher structures)
lifting door
side-opening
7
lifting door
side-opening
Ø250
289
512
334
333
205
1627
205
1627
379
232
232
313
313
800
800
561
393
604
1902
Ø246
385
205
1632
606
232
313
232313
800
800
454
347 39
1
3911632
205
400
595
1907
Ø250 Ø246
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
Eck-Kamin 57/67/44 r/l
BSK 02a
8
9BSK 02 - Plastered surface
a BSK 02 left a BSK 02 right
Individualized.If the standard fireplace design is just not enough, you can explore your ideas and inspirations using our BRUNNER construction plates.
With the optional protective panels installed inside, your BSK fireplace kit can be assembled just in front of a wall without the risk of overheating.
Provided on site:
Air intake at the bottom rear of fireplace.
Additional wood storage compartment made with our construction plates.
10
Dimensions & Technical Data.BSK 02a
595
BSK 02 Fireplace:
57/67/44 corner
Rated heating power kW 11
Wood consumption kg/h 3,2
Necessary supply pressure Pa 13
Flue gas mass flow g/s 13
Flue gas temperature behind steel hood
°C 225
Smoke outlet mm ø 200
Required combustion air m3/h 32
Combustion air connection mm ø 125
Cladding components:
Ground area (width x depth) mm 950 x 770
Overall height mm 1895
Height extension ring mm 300
Wall thickness mm 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50
Distance to the ceiling mm 600
Insulation thickness for ceiling, with/without warm air grating
mm 140/190
Air intake opening area* cm2 800
Warm air outlet area for top cover plate
cm2 965
Total weight kg 646
Tested according to EN 13229
* Air intake opening in bottom area must be provided on site.
Height extension ring(additional cladding part for even higher structures)
11
right
left
467
33744
8
546
1709
218
400
595
757
218
1709
527
1895
385
218
Ø240
310
284
Ø 2
61
950
770
467
337 44
8
546
385
218
Ø 240
310
284
Ø 2
61
950
770
218
1709
527
1895
1709
218
400
595
757
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
12
Eck-Kamin 57/82/48 r/l
BSK 03a
BSK 03 - Plastered surface
Harmonious.Room-high column with plastered walls and natural colours.
Provided on site:
Air intake at the bottom rear of fireplace.
Warm air outlet on back walls, 500 mm
below the ceiling area.
Insulation of ceiling.
13
a BSK 03 right a BSK 03 left
14
Dimensions & Technical Data.BSK 03a
* Air intake opening in bottom area must be provided on site.
595
BSK 03 Fireplace:
57/82/48 corner
Rated heating power kW 12
Wood consumption kg/h 3,6
Necessary supply pressure Pa 13
Flue gas mass flow g/s 13
Flue gas temperature behind steel hood
°C 210
Smoke outlet mm ø 250
Required combustion air m3/h 32
Combustion air connection mm ø 125
Cladding components:
Ground area (width x depth) mm 1100 x 742
Overall height mm 1896
Height extension ring mm 300
Wall thickness mm 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50
Distance to the ceiling mm 600
Insulation thickness for ceiling, with/without warm air grating
mm 190/140
Air intake opening area* cm2 1000
Warm air outlet area for top cover plate
cm2 1332
Total weight kg 705
Tested according to EN 13229
Height extension ring(additional cladding part for even higher structures)
15
right
left
542
377
621
448
387
1896
340
Ø292
273
1688
567
403
595
Ø 311
1687
340
907
311
302
742
1100
387
1896
340
Ø292Ø290
Ø 311
273
1688
567
403
595
311
302
742
1100
621
448
1687
340
907
542
377
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
16
Stil-Kamin 62/76
Stil-Kamin Tunnel 62/76
Kamin-Kessel 62/76 (without boiler insulation)
BSK 04a
a BSK 04 a BSK 04 Tunnel
17
BSK 04 - Unfinished thermal concrete surface with shadow joint
Puristic.The most substantial form and look of a fireplace. Raw concrete elements are assembled using a slightly darker joint seal. “Crude” surface and sharp edges are characteristic for this material and not considered as defects. To achieve a desired level of smoothness, we recommend to wipe the concrete surface with an abrasive pad.
Smoke outlet for all models available left / right / top / rear.
Provided on site:
Air intake at the bottom of fireplace depending on individual needs.
18
Dimensions & Technical Data.BSK 04a
* Air intake opening in bottom area must be provided on site.
BSK 04 Fireplace:
Stil 62/76 Stil Tunnel62/76
Kamin- Kessel 62/76lifting door (without boiler insulation)
Rated heating power kW 9 9 13
Wood consumption kg/h 3,0 3,0 3,8
Necessary supply pressure Pa 13 13 12
Flue gas mass flow g/s 12 12 13
Flue gas temperature behind steel hood
°C 190 175 180
Smoke outlet mm ø 250 ø 250 ø 250
Required combustion air m3/h 35 35 35
Combustion air connection mm ø 125 ø 125 ø 125
Cladding components:
Ground area (width x depth) mm 1230 x 715 1230 x 715 1230 x 715
Overall height mm 1898 1898 1898
Height extension ring mm 322 322 322
Wall thickness mm 30/35 30/35 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0 0 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 0 50 0
Distance to the ceiling mm 600 600 600
Insulation thickness for ceiling, with/without warm air grating
mm 160/220 160/220 160/220
Air intake opening area* cm2 1200 1200 1200
Warm air outlet area for top cover plate
cm2 1540 1540 1540
Total weight kg 548 507 779
Tested according to EN 13229 EN 13229 EN 13229
Height extension ring(additional cladding part for even higher structures)
Accessory:Additional support for Kamin-Kessel 62/76
19
Stil 62/76
Stil Tunnel 62/76
Kamin-Kessel 62/76 lifting door without boiler insulation
274
300
632
442185
358
358
1230
715
R158
1681
335 560
233 764
1661
357
Ø 301
560335
1681
1661
233 764
305
300
632
513
513
615
100100
358
603 185
R158
1230
715
1661
357
1898
Ø301
274
300
632
357
602 185
1230
715
1681
335 560
233 764
1661
357
1898
420
615
440
440
10°10°
Ø301
R158
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
Note: for horizontal or lateral connecting piece entry, an additional ring as part of external cladding is necessary.
20
BSK 05 - Plastered wall surface - Heat screen & Fire table (groove pattern)
Elegant.BSK fireplaces can be furnished with extra-large tiles including heat screens and fire tables. The combination of available tiles and colours decides about the final effect. Ceramic tiles are easy to clean and remain beautiful over the years.
Provided on site:
Air intake at the bottom rear of fireplace.
Warm air outlets for sidewalls, 500 mm below the ceiling area.
Insulation of ceiling.
21
Panorama-Kamin 57/40/60/40
BSK 05a
a BSK 05
22
Dimensions & Technical Data.BSK 05a
* Air intake opening in bottom area must be provided on site.
1050
BSK 05 Fireplace:
Panorama57/40/60/40
Rated heating power kW 13
Wood consumption kg/h 4
Necessary supply pressure Pa 12
Flue gas mass flow g/s 14
Flue gas temperature behind steel hood
°C 340
Smoke outlet mm ø 250
Required combustion air m3/h 40
Combustion air connection mm ø 160
Cladding components:
Ground area (width x depth) mm 802 x 880
Overall height mm 1898
Height extension ring mm 363
Wall thickness mm 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50
Distance to the ceiling mm 600
Insulation thickness for ceiling, with/without warm air grating
mm 160/220
Air intake opening area* cm2 800
Warm air outlet area for top cover plate
cm2 986
Total weight kg 582
Tested according to EN 13229
Height extension ring(additional cladding part for even higher structures)
Stiffening clamps
23
Panorama-Kamin 57/40/60/40
666
401
151
161
45°
510
317
401
802
88017
4
1898
1451
230
580
ø 313
Ø 292
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
24
Architektur-Kamin 45/101
Architektur-Kamin Tunnel 45/101
Kamin-Kessel 45/101
Kamin-Kessel Tunnel 45/101
BSK 06a
a BSK 06 a BSK 06 Tunnel
25
BSK 06 - Plastered wall surface - Fireplace frame (groove pattern), Plinth (glossy)
Stylish.Fireplace in horizontal format as room divider. This model comes not just with a heat screen, but also a ceramic fireplace frame. The extra-large tiles are affixed to the plastered walls using a special mounting kit.
Provided on site:
Warm air outlet on back wall, 500 mm below the ceiling area.
Insulation of ceiling.
26
BSK 06 Fireplace:
Architektur 45/101
Architektur 45/101 Tunnel
Kamin-Kessel 45/101
Kamin-Kessel 45/101 Tunnel
Rated heating power kW 14 15
Wood consumption kg/h 4,3 4,4
Necessary supply pressure Pa 12 12
Flue gas mass flow g/s 16 16
Flue gas temperature behind steel hood
°C 220Tunnel: 205
170
Smoke outlet mm ø 250 ø 250
Required combustion air m3/h 40 45
Combustion air connection mm ø 125 ø 125
Cladding components:
Ground area (width x depth) mm 1550 x 690 1550 x 690
Overall height mm 1899 1899
Height extension ring mm 345 345
Wall thickness mm 30/35 30/35
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50 50
Distance to the ceiling mm 600 600
Insulation thickness for ceiling, with/without warm air grating
mm 180/250 180/250
Air intake opening area cm2 811 811
Warm air outlet area for top cover plate
cm2 1035 1035
Total weight kg 633 Tunnel: 606
960 Tunnel: 987
Tested according to EN 13229 EN 13229
Dimensions & Technical Data.BSK 06a
42
272
319
176
140
Ø19
8
Ø250
280
Accessories for lower Kamin-Kessel design with horizontal flue connection ø 200 mm.
Height extension ring(additional cladding part for even higher structures)
27G Warm air outlet G Combustion air connection G Optional exhaust gas outlets G Air intake
775
Kamin-Kessel Tunnel 45/101
Architektur-Kamin Tunnel 45/101
Kamin-Kessel 45/101
Architektur-Kamin 45/101
Tunnel
5296
5265
1679 18
99
1899
1899
268 1014
1675
5265
345
5296
345
775
690
1550
314
464
400
775
345
374
400
464
775
1675
268 101434
5
775
1550
690
345
1674
400
464
1899
315
1675
345
374
400
464
1899
353
775
390
single door
28 28
Architektur-Kamin Eck 38/86/36 r/l
BSK 07a
a BSK 07 low a BSK 07 high
29 29
BSK 07 high - Plastered wall surface
Changeable.Two structural variants, with completely different appearance but the same compact dimensions.
For the lower variant with overall height of 160 cm, the fire table starts 40 cm above floor level. With an additional ring and support frame, the fireplace can be placed 80 cm above floor level.
Provided on site:
Air intake at bottom
2 cm insulation panel for wooden wall
30
Dimensions & Technical Data.BSK 07a
* Air intake opening in bottom area must be provided on site.
BSK 07 Fireplace:
BSK 07 low
Architektur 38/86/36 r/l
BSK 07 high
Architektur 38/86/36 r/l
Rated heating power kW 10 10
Wood consumption kg/h 3,1 3,1
Necessary supply pressure Pa 12 12
Flue gas mass flow g/s 11 11
Flue gas temperature behind steel hood
°C 220 220
Required combustion air m3/h 30 30
Combustion air connection mm ø 125 ø 125
Cladding components:
Ground area (width x depth) mm 1093 x 600 1093 x 600
Overall height mm 1603 2002
Height extension ring mm 400 400
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50 50
Distance to the ceiling mm 600 600
Insulation thickness for ceiling, with/without warm air grating
mm 200/280 200/280
Air intake opening area* cm2 900 900
Warm air outlet area for top cover plate
cm2 1200 1200
Total weight kg 563 660
Tested according to EN 13229 EN 13229
Ø205
Ø19
8
407
257
122
239
250
Smoke pipe adapter for horizontal or central-vertical flue connection ø 200 mm.
Height extension ring(additional cladding part for even higher structures)
Accessory:Support frame for the higher variant
31
AK 38/86/36l - low
AK 38/86/36 l high
1603
898
Ø220
299
221
403
398
398
428237
1391
387
296 36
4
520
ø220
422 250
305
1093
600
2002
898
Ø220
299
221
803
398
398
428237
1791
Ø220
296 36
4
520422 250
305
1093
600
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
32
Kompakt-Kamin 51/67
BSK 08a
a BSK 08 side-opening a BSK 08 lifting door
33
BSK 08 - Unfinished thermal concrete surface with shadow joint
Balanced.Harmonic interaction between the classic fireplace and minimalistic exterior design.
The various structural features and shades visible on the concrete cladding surface (exposed concrete class 2-3) will set the optical accents.
Provided on site:
Air intake at the bottom or rear of fireplace.
34
Dimensions & Technical Data.BSK 08a
* Air intake opening in bottom area must be provided on site.
BSK 08 Fireplace:
BSK 08
KK 51/67 f lifting door
BSK 08
KK 51/67 f side-opening
Rated heating power kW 11 11
Wood consumption kg/h 3,3 3,3
Necessary supply pressure Pa 13 13
Flue gas mass flow g/s 10,5 10,5
Flue gas temperature behind steel hood
°C 250 250
Required combustion air m3/h 40 40
Combustion air connection mm ø 125 ø 125
Cladding components:
Ground area (width x depth) mm 1100 x 760 1100 x 760
Overall height mm 1762 1762
Height extension ring mm 280 280
Distance to adjacent wall in direct contact (with radiation panels inside)
mm 0 0
Distance to adjacent wall for free-standing design(without radiation panels inside)
mm 50 50
Distance to the ceiling mm 600 600
Insulation thickness for ceiling, with/without warm air grating
mm 120/160 120/160
Air intake opening area* cm2 1000 1000
Warm air outlet area for top cover plate
cm2 1330 1330
Total weight kg 673 622
Tested according to EN 13229 EN 13229
Height extension ring(additional cladding part for even higher structures)
35
KK 51/67 f lifting door
KK 51/67 f side-opening
Ø210 190
395
524
706
Ø210378
392
530
307
1762
550
575
225
314
210
466
70
760
1100
Ø210 190
736384
546
Ø210378
311
392
530
518
225
Ø124
257
1762
210
466
70
760
1100
550
G Warm air outlet G Combustion air connection G Optional exhaust gas outlets
Watch this video to learn moreExample BSK 08 (installation procedure)
Assemblya
External cladding of all BSK fireplaces consists of precisely fitted and statically stable thermal concrete with inner reinforcement.
The exact alignment of baseplate (1) must be checked with spirit level and angle to ensure the correct vertical position and right angle. The fireplace is positioned on this baseplate and then all other components are assembled.
For all models except BSK 06, it must be considered that the air intake opening in the bottom area of the fireplace must be arranged according to optical and structural conditions on site.
It must be made the same way as for the required connecting piece opening, using a cutting disc, a jigsaw or a core drill.
For the machining of thermal concrete cladding we recommend diamond-tipped tools (drills, jigsaw blades, core drilling crowns and files). For more information visit www.brunner.de/de/Videos/Start.
If the fireplace shall have external air supply, it has to be furnished directly after the installa-tion of the firebox is completed.
36
Radiation panels for protection
Our Recommendation:
Plastered walls.a
For the plastered walls of our BSK fireplaces we offer a specially developed, high temperature resistant plastering system. It starts with a glassfiber mesh, which is laid with the ORTNER-Haftputz adhesive mortar. The glassfiber mesh serves in addition as reinforcement for the thin plaster.
The working procedure is limited to 2 coats only.
The contact and embedding layer for the glassfiber mesh laid on thermal concrete.
The clean or final layer (1 – 4 mm thickness).
The surface can be finished with different techniques including rubbed, solid or smooth plaster finish.
Natural colour tone after drying out: clear white.
Painting is allowed only with materials for heated walls.
Caution: Never use polymer modified paints, latex paint, etc.
37
Haftputz plaster 20 kg 0 – 0,5 mm(natural base materials, fiber-reinforced with no synthetic components, neutral odor)
Other special plasterwork products, like Glattspachtelputz or Modellierputz must be used only on glassfiber mesh with Haftmörtel adhesive mortar according to data sheets.
Glassfiber mesh, mesh size 6 mm
Suitable extra-large tiles “made in germany” for BSK 01-06,
for assembly on plastered wall surface (including mounting kit).
Tile furnishing optionsa
a BSK 01 Picture: Heat screen with groove pattern
a BSK 03 Picture: Heat screen with wave pattern Fire table, glossy
a white shiny (90) a ivory matte (160) a red shiny (303) a cabana brown (58)a crystal white (795) a shale grey dark (960)
Available colours:
a BSK 02 Picture: Heat screen with wave pattern Fire table, glossy
38
a BSK 04 Picture: Heat screen with groove pattern Fire table, glossy
a BSK 05 Picture: Heat screen with groove pattern Fire table, groove pattern/glossy
a BSK 06 Picture: Fireplace frame with groove pattern Plinth, glossy
a BSK 04 Picture: Heat screen with wave pattern
a BSK 05 Picture: Fire table, glossy
a BSK 06 Picture: Heat screen with wave pattern Fire table, glossy
39
System Fireplaces by BRUNNER.
There is no better way to build a quality fireplace quicker and cheaper.
Exactly dimensioned thermal concrete components make it possible to build
a completely finished fireplace within a few hours.
Form and design of these fireplace construction sets ensure best functionality
and safe installation at minimal space requirements.
Form:
straight lines & simple shapes
Finish:
unfinished concrete look, grey with shaded joints (exposed concrete class 2-3)
plastered surface / individual painting
Technics:
BRUNNER fireplace inserts with room-dependent or external combustion
air supply
Options:
extra-large tiles including heat screens and fire tables
Provided on site:
insulation of ceiling for room-high structures
arrangement of air intake/warm air outlets according to optical and room-
dependent conditions
made in germany.
Ulrich Brunner GmbHZellhuber Ring 17 - 18D-84307 EggenfeldenPhone: +49 / (0)8721 / 771-0Fax: +49 / (0) 8721 / [email protected] · www.brunner.eu
BRUNNER products are offered and sold only by qualified dealers and service centres. Subject to technical and assortment changes. Errors excepted.Status 04/2012 · Ver. 1.2 · BRU1073 · 5K · atwerb.de
BSK 06 - Plastered surface