1M-12.10 V.3 Elk Grove Village 1200 Greenleaf Avenue Elk Grove Village, IL 60007 Tel: (847) 437-9690 Fax: (847) 437-0741 Peoria 7700 North Harker Dr., Suite B Peoria, IL 61615 Tel: (309) 691-5160 Fax: (309) 691-6437 www.bruckerco.com BRUCKER COMPANY STOCK CATALOG Stock Catalog
122
Embed
BRUCKER COMPANY STOCK · PDF file1M-12.10 V.3 Elk Grove Village 1200 Greenleaf Avenue Elk Grove Village, IL 60007 Tel: (847) 437-9690 Fax: (847) 437-0741 Peoria 7700 North Harker Dr.,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1M-12.10 V.3
Elk Grove Village1200 Greenleaf Avenue
Elk Grove Village, IL 60007Tel: (847) 437-9690Fax: (847) 437-0741
Peoria7700 North Harker Dr., Suite B
Peoria, IL 61615Tel: (309) 691-5160Fax: (309) 691-6437
www.bruckerco.com
BRUCKER COMPANY STOCK CATALOG
Stock Catalog
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Elk Grove Village1200 Greenleaf Avenue
Elk Grove Village, IL 60007Tel: (847) 437-9690Fax: (847) 437-0741
Peoria7700 North Harker Dr., Suite B
Peoria, IL 61615Tel: (309) 691-5160Fax: (309) 691-6437
www.bruckerco.com• Order stock online• Check order status• View Manufacturer Data
to get the job done NOW.We have the materials you need
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
ABB, lnc.www.abb.us/drives com• Adjustable frequency drives
for fans, pumps, and cool-ing towers
• Control products
Air Concepts www.airconceptsinc.com• Punkah louvers/drum
louvers •Air nozzles
Air Flow Technologywww.airflowtechnology.com• Medium to high efficiency
Data-Aire, Inc.www.dalaaire.com• Computer room air condi-
tioners • Computer room chillers
FabricAirwww.fabricair com • Fabric ducts
Greenheck Fan Corporationwww.greenheck com• Power roof ventilators• Panel propeller fans• Vane axial fans• Centrifugal fans• Make-up air systems• Kitchen exhaust hoods• Fire and smoke dampers• Louvers, control dampers• Energy recovery ventilators• Laboratory exhaust
Vent Productswww.ventprod.com• Louvers, control dampers• Louvered penthouses• Fire and smoke dampers• Curb equipment supports
Viron Internationalwww.vironintl.com• FRP & PVC fans, duct work
& hoods• Scrubbers• Coated stainless duct
WaterFurnacewww.waterfurnace.com• Water source heat pumps• Geothermal systems
Winkler Manufacturing •Blast gates
Young Regulator Companywww.youngregulator.com• Manual dampers• Motorized dampers• Remote control dampers &
controllers
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
TABL
E OF
CON
TENT
S
TABLE OF CONTENTS
GreenheckCentrifugal Roof Exhaust Direct Drive – G 2Centrifugal Roof Exhaust Belt Drive – GB 4Upblast Roof Exhaust Direct Drive – CUBE 8Sidewall Exhaust Direct Drive – CWB 11Ceiling Exhaust Fans – SP 12Inline Cabinet Exhaust Fans – CSP 14Roof & Wall Discharge Accessories 16Inline Fans – Direct Drive and Belt Drive – SQ/BSQ 18Sidewall Propeller Fan – Direct Drive – SE 21Sidewall Propeller Fan – Belt Drive – SBE 23Sidewall Fan Accessories – SE/SBE 25Gravity Ventilators – GRS 26Centrifugal Utility Fans – SFB 27Centrifugal Utility Fans – SWB 28Ceiling Radiation Dampers 30Dynamic Fire dampers – DFD-150/DFDR-510 30Backdraft Dampers, Curbs & Equipment Supports 31ABBVariable Frequency Drives 34Model UH Base Drive 35Model VCR Vertical Bypass with Circuit Breaker 36
BrOAnBath Fans 38Ventilation Fans - Ultra Silent™ 39Combination Units 40Wall Heaters 41LoSone Ventilators 42Broan Controls 43Roof and Wall Caps 44
Price industriesFixed Blade Return Grilles and Registers Model 530 and 530D 46Filter Return Grilles Model 530FF 47Light Shields 47Round Diffusers Model RCDE 49Door/Transfer Grilles Model STG1 50Double Deflection Supply Grilles Model 520D & Single Deflection Supply Grilles Model VM 51High Capacity Drum Louvers Model HCD1D 56Square Cone Diffusers Model SCD/Plaster Frames 57Square Cone Diffusers Model SCDA Adjustable Air Pattern/Plaster Frames 59Square Plaque Diffusers Model SPD/Plaster Frames 61 Linear Slot Diffuser Model SDS 63Linear Slot Diffuser Plenums Model SDBI 64Price industries (continued)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
TABLE OF CONTENTS (continued)
T-Bar Supply Diffusers Model TBDI4 65Perforated Supply Diffusers Model PDF/PDFE 67Perforated Return Diffusers Model PDDR/PDDRE (Matching Return for PDF/PDFE) 70Dampers 72Spiral Duct Mount Grilles Model SDG 73Louvered Face Diffusers Model SMD 73Egg Crate Grilles Model 80/Plaster Frames 75Round Neck Adaptors Model SR3 77Single Duct – Controller Type SPV, SDV, SEV Series 78Control Sequence Model SPV/SEV 82VAV Diffuser Varitherm® Model VPD-HC 83
reliABle PrOductsFloor Diffusers 86
Access dOOrsAccess Doors – Hinged or Double Catch Lock 88
FlexiBle technOlOGies, triAnGle MAnuFActurinGFlexible Tubing 90Locking Ties 90
Q’MArk, leAdinG edGe & therMOstAtsUnit Heaters Type MUH 92Architectural Heavy-Duty Wall Heaters — Type AWH-4000 94Commercial Wall Heaters – Fan-Forced — Type CWH-1000 95Commercial Wall Heaters – Fan-Forced — Type CWH-3000 96Ceiling Mounted Heaters – Fan-Forced — Type QCH 97Electric Baseboard Heaters — Type 2500 97Commercial Downflow Ceiling Mounted Heaters — Type CDF 98Heat Recovery Ceiling Fans (Leading Edge) 99Thermostats 101
MiscellAneOus suPPlies And PrOductsVibration Isolators 104Motors 105
YOunG reGulAtOrsDampers and Controls 108Remote Cable Controls 108Socket Wrench 108Casing and Wire 108
cerus industriAlMotor Starters – Model BAS 110Motor Starters – Model BAS-1P 110
PurOlAtOrhi-E 40™ Pleated Filter 112Defiant® Mark 80D™ Pleat 113
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 1
GREE
NHEC
K
GREENHECK
Centrifugal Roof Exhaust Direct Drive – G 2
Centrifugal Roof Exhaust Belt Drive – GB 4
Upblast Roof Exhaust Direct Drive – CUBE 8
Sidewall Exhaust Direct Drive – CWB 11
Ceiling Exhaust Fans – SP 12
Inline Cabinet Exhaust Fans – CSP 14
Roof & Wall Discharge Accessories 16
Inline Fans – Direct Drive and Belt Drive – SQ/BSQ 18
Sidewall Propeller Fan – Direct Drive – SE 21
Sidewall Propeller Fan – Belt Drive – SBE 23
Sidewall Fan Accessories – SE/SBE 25
Gravity Ventilators – GRS 26
Centrifugal Utility Fans – SFB 27
Centrifugal Utility Fans – SWB 28
Ceiling Radiation Dampers 30
Dynamic Fire Dampers – DFD-150/DFDR-510 30
Backdraft Dampers, Curbs & Equipment Supports 31
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Centrifugal Roof Exhaust Direct Drive - GModel G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the G models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
*May be greater depending on motor. All dimensions in inches.Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
A
B
C
13/4 in.
*
UL/cUL 705 E40001 - G
G Condensed PerformanCe & dimensional data
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 3
GREE
NHEC
K
Centrifugal Roof Exhaust Direct Drive - GOPTiOnS AnD ACCESSORiES • Gravity and motorized dampers• Galvanized roof curbs• Speed controls
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing • non-overloading backward inclined wheel • Aluminum curb cap with prepunched mounting holes • integral reinforced bead for strength on hood • Galvanized birdscreen • Ball bearing motors (sizes 101-180), sleeve bearing motors (sizes 060-095) • Motor isolated on shock mounts • Corrosion resistant fasteners • nema-1 disconnect• UL/cUL 705 Electrical
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com4
A
B
C*
13/4 in.
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
GB Condensed PerformanCe ranGes & dimensional data
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the G models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Centrifugal Roof Exhaust Belt Drive - GBModel GB Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 5
GREE
NHEC
K
Centrifugal Roof Exhaust Belt Drive - GBOPTiOnS AnD ACCESSORiES • Gravity and motorized dampers• Galvanized roof curbs
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• non-overloading backward inclined wheel• Galvanized birdscreen• integral reinforcing bead for strength• Double studded isolators for true vibration isolation• Motor out of airstream• Motor pulley is adjustable for system balancing• nema-1 disconnect• Lifting lugs (mid and larger sizes)• UL/cUL 705 Electrical
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
GB PerformanCe data - in stoCk Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com6
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
GB Performance data - in stock Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Centrifugal Roof Exhaust Belt Drive - GB
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com8
B
C*D
A
13/4 in.
Greenheck Fan Corporation certifies that the CUBE models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
*May be greater depending on motor. All dimensions in inches.^Dampers should not be used in grease applications.Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
CUBe Condensed PerformanCe ranGes & dimensional data
For complete product information contact your Brucker sales representative.
Upblast Roof Exhaust Belt Drive - CUBEModel CUBE Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted applications. Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 9
GREE
NHEC
K
Upblast Roof Exhaust Belt Drive - CUBEOPTiOnS AnD ACCESSORiES • Galvanized birdscreen• Gravity and motorized dampers for non-UL 762
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• non-overloading backward inclined aluminum wheel• Curb cap with prepunched mounting holes• Motor and drives isolated on shock mounts• Drain trough• Ball bearing motors• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearings• Static resistant belts• Corrosion resistant fasteners• nema-1 disconnect• Heat baffles• UL/cUL 705 Electrical• UL/cUL 762 Grease• Drain connection
CUBe HiGH PressUre Condensed PerformanCe ranGes & dimensional data - in stoCk
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.^Dampers should not be used in grease applications.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
MODEL A B C* D ROOF OPENING
DAMPER SIZE^
MIN/MAX RPM
SONES @ .5 in.
PERFORMANCE IN INCHES WG
.5 .75 1.25 1.75 2.25 2.75
CUBE-101HP 19 247/8 233/4 173/8 141/2 x 141/2 12 x 121300 6.0 335
2580 16.8 1014 969 861 735 550
CUBe PerformanCe data - in stoCk Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
CUBe PerformanCe data - in stoCk Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Upblast Roof Exhaust Belt Drive - CUBE
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 11
GREE
NHEC
K
Sidewall Exhaust Direct Drive - CWB
CWB standard Condensed PerformanCe ranGes & dimensional data
MODEL A B** C WALL OPENING
DAMPER SIZE^
IN STOCK SIZES (n)
MIN/MAX RPM
SONES @ 0 in.
PERFORMANCE IN INCHES WG0 .25 .5 .75 1 2
CWB-141 287/8 293/4 221/8 151/2 x 151/2 15 x 15 n590 5.0 1069
1725 26 3125 3005 2865 2711 2539
CWB-180 353/8 285/8 273/4 171/2 x 171/2 17 x 17 n630 7.1 2380 1861
1495 28 5648 5443 5254 5082 4921 3564
• Aluminum housing• non-overloading backward inclined aluminum wheel• Birdscreen mounted to the discharge perimeter• Removable mounting plate• Ball bearing motors• Motors and drives isolated on shock mounts• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• nema-1 disconnect• UL/cUL 705 Electrical• UL/cUL 762 Grease (Size 098 and up)
• Gravity and motorized dampers for non-UL 762 applications
OPTiOnS AnD ACCESSORiES STAnDARD COnSTRUCTiOn FEATURES
**May be greater depending on motor. All dimensions in inches.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.^Dampers should not be used in grease applications.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com12
Ceiling Exhaust Fans - SPModel SP Ceiling Exhaust fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 13
GREE
NHEC
K
C
D
B A
E
B A
C D
BA
C D
E
E
C
B A
DE
All dimensions in inches.Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type B: free inlet sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only.
sP PerformanCe & dimensional data - in stoCk
UL/cUL 507E33599 Ceiling Exhaust Fans are also UL Listed for sizes 50 through 390 for above bathtub/shower with GFCi branch protected circuit. File no. E33599
MODEL A B COUTLET
RPM AMPS WATTS SONES @ 0 IN. GRILLE SIZE
PERFORMANCE IN INCHES WGD E 0.00 .100 .125 .250 .375 .500 .625 .750 1.00
SP-C50 SP-A110 through SP-A510 and SP-A710 & SP-A780
SP-B50 through SP-B200 SP-A700, SP-A900 & SP-A1550
Greenheck Fan Corporation certifies that the SP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Ceiling Exhaust Fans - SP
For complete product information contact your Brucker sales representative.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com14
Inline Cabinet Exhaust Fans - CSPModel CSP inline Cabinet fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.
PERFORMAnCEModels CSP-B110 through A3600 are duct mounted with performance capabilities of 77 cfm to 3,778 cfm and up to 1 in. wg of static pressure.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 15
GREE
NHEC
K
Inline Cabinet Exhaust Fans - CSP
Greenheck Fan Corporation certifies that the CSP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
CsP PerformanCe and dimensional data - in stoCk
UL/cUL 507E33599 Cabinet Fans are also UL Listed for above bathtub/shower with GFCi branch protected circuit. File no. E33599
MODEL A B C D E F G RPM AMPS WATTS WT PERFORMANCE IN INCHES WG0 .125 .25 .375 .5 .75 1
All dimensions in inches.Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) from the test inlet duct in a hemispherical free field calculatd per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction. Ratings are based on 10 ft. of insulated duct. The AMCA Certified Ratings Seal applies to air performance only.
For complete product information contact your Brucker sales representative.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com16
Roof & Wall Discharge Accessories
All dimensions in inches.
All dimensions in inches.
All dimensions in inches.
B
Dia. DC
A
11/2 in.
MODEL RCC-7• Weathertight aluminum construction • integral birdscreen • Built in curb cap • Requires roof curb
A
B
CD
E
MODEL RJ Pitched Roof Cap• Steel construction with black enamel finish • integral flashing flange • Built in birdscreen and damper
B
CD
Dia.A
13/4 in.
B
CD
Dia.A
111/8
31/2
10
91/4
11 1/2
51/8
MODEL GRS• All aluminum exterior
construction• Galvanized steel internal supports • integral birdscreen • Built in curb cap • Requires roof curb
MODEL EL - 10x3 Elbow Discharge with Grille• Designed for installation under roof eaves • Painted steel louvered grille • Built in damper • For SP/CSP sizes 50-290
CURB CAP
B
Dia. DC
A
MODEL RFC-7• Weathertight aluminum construction • integral birdscreen • Built in flashing flange
FLASHinG FLAnGE
HAnGinG ViBRATiOn iSOLATORSVibration isolator kits are available for suspended installations. Kits include all hardware necessary to mount one unit, with the exception of 10-32 threaded rod to be supplied by others. Fan mounting brackets include prepunched mounting holes for ease of installation.
Above accessories tested with 4 feet of inlet duct
WC-10x3WC-6RJ-6x9EL-10x3WL-10x3BVE-808RFC-7RCC-7
BVE-128WC-8x8WC-8
BVE-157WC-18x8
RJ-10x10
WL-18x6
CF
M x
100
ACCESSORY PRESSURE DROPSThe chart below can be used with all of the discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection.
*Used in conjunction with RDC-6.All dimensions in inches.
All dimensions in inches.All dimensions in inches.
• Galvanized steel housing• non-overloading backward inclined aluminum wheel• Side access panels• inlet and outlet duct connection flanges• Ball bearing motors• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Motor covers-standard• Gravity and motorized Dampers• isolators
STAnDARD COnSTRUCTiOn FEATURES
A
C sq.
D*
C sq.B sq.
A 1 in.1 in.
C sq.
B sq.
C sq.
B sq.
sQ standard Condensed PerformanCe ranGes & dimensional data
* May vary depending on motor size.
SQ BSQ
All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Inline Fans Direct Drive and Belt Drive - SQ/BSQModels SQ and BSQ are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where space is a prime consideration. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.
Model SQ Centrifugal inline fans are direct drive. Maximum operating temperature is 130º F
Model BSQ Centrifugal inline fans are belt drive. Maximum operating temperature is 180º F.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Inline Fans Direct Drive - SQ
Hanging Vibration isolator - Model HVi(Hanger rods supplied by others)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com20
Inline Fans Belt Drive - BSQ
BsQ PerformanCe data - in stoCkStock Model BSQ fans include disconnect switch, motor cover UL/cUL 705.
Greenheck Fan Corporation certifies that the SQ, BSQ models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
UL/cUL 705E40001 - SQ/BSQ
For complete product information contact your Brucker sales representative.
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 21
GREE
NHEC
K
For complete product information contact your Brucker sales representative.
F*D
B*C* D
E
AirflowExhaust
AirflowSupply
A Sq.
Greenheck Fan Corporation certifies that the S models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
direCt drive s standard & dimensional data - steel ProPeller
*May vary due to motor sizes. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
LEVEL 1 - SIZE 8-12 - D, G, E Motor SpeedsLEVEL 1 - SIZE 12-24
Sidewall Propeller Fan - Direct Drive - SESidewall Propeller direct drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated aluminum, fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Direct drive fans are often preferred for jobs where maintenance access is difficult.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com22
Sidewall Propeller Fan - Direct Drive - SE
All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
direCt drive se1 PerformanCe data - in stoCkStock Model SE1 fans are direct drive exhaust and include aluminum propeller, heavy gauge wire motor support, fan guard, UL/cUL 705 and CSA labels.
MODEL MOTOR SPEED
SONES @ 0 in.
FANRPM
#BLADES
PROPPITCH DAMPER
PERFORMANCE IN INCHES WG
0 .1 .125 .25 .375
SE1-8-DGEX
E 1.5 1050 4 40 10 x 10 311 126 100
G 3.5 1350 4 40 10 x 10 399 256 198
D 4.9 1550 4 40 10 x 10 459 351 307 167
SE1-10-DGEX
E 3.2 1050 4 40 12 x 12 626 361
G 4.9 1350 4 40 12 x 12 804 655 615
D 5.9 1550 4 40 12 x 12 924 800 763
SE1-12-DGEX
E 4.3 1050 4 32 14 x 14 982 745 678 383
G 6.0 1350 4 32 14 x 14 1262 1098 1038 798 541
D 7.5 1550 4 32 14 x 14 1449 1309 1271 1042 861
SE1-14-BX B 7.3 1160 4 40 16 x 16 1604 1406 1350 908 720
SE1-18-BX B 10.2 1160 4 29 20 x 20 3238 2987 2908 2434 1510
SE1-20-BX B 13.8 1160 4 28 22 x 22 4227 4030 3974 3621
STAnDARD COnSTRUCTiOn FEATURES• Heavy gauge, galvanized steel fan panel with pre-punched mounting holes• Resilient motor mounts isolate motor vibrations• Corrosion resistant fasteners• ODP single phase• Thermal overload protection with all motors• Level 1 Riveted Aluminum Blades
Sizes 8-12 (D, G, E motor speeds) - Heavy gauge welded zinc plated wire drive frame Sizes 12-24 (A, B, C motor speeds) - Die formed, galvanized steel drive frame assembly
• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Wall housings with inlet guard• Speed controls• Gravity and motorized dampers
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 23
GREE
NHEC
K
Sidewall Propeller Fan - Belt Drive - SBESidewall Propeller belt drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Also two blade designs are available: The “L" design is for low static pressures and low sound levels. The “H" design is for higher static pressures. Belt drive fans offer the ability to adjust fan speed for system
Belt drive sBe Condensed PerformanCe ranGes & dimensional data–steel ProPeller
All dimensions in inches. Please note: Optimum selections shown in bold.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the SB models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
STAnDARD COnSTRUCTiOn FEATURES• Die formed, galvanized steel drive frame assembly• Adjustable motor pulley• Ball bearing motors• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• Level 1 Galvanized and riveted steel blades• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Wall housings with inlet guard• Gravity and motorized dampers
E
B
AirflowExhaust
F
AirflowSupply
A sq.
C D D
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com24
Sidewall Propeller Fan - Belt Drive - SBE
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 25
GREE
NHEC
K
Sidewall Fan Accesories - SE/SBE
Wall HoUsinG dimensional data
WALL HOUSinG & ACCESSORiESWall housings are the safest and most efficient platform for mounting of sidewall propeller fans and their optional accessories. Wall housings allow for a wide range of mounting arrangements to meet specific applications, and can be mounted flush inside, flush outside, or centered in wall. Standard construction is of galvanized steel.
*Select only one. Shown together for illustration only.
Damper
Wall Housing and OSHA Guard - (Std.)
Damper Guard*
Weatherhood*(45º Exhaust only shown)
B
A W.O.
C E
FD
* B dimension will increase by 6 in. when a heavy duty motorized backdraft damper is specified.For complete dimensional information refer to submittal. All dimensions given in inches.
t non-stock items available on next day quick delivery.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com26
Gravity Ventilators - GRSModel GRS is an aluminum ventilator designed for intake (Model GRSi) or relief (Model GRSR) applications with either natural gravity or positive pressure systems. The GRS appearance blends with other Greenheck products and with its low silhouette, avoids the problem of detracting from architectural aesthetics. Exceptional design and construction features make this unit a rugged, efficient, and economical air inlet or outlet.
B
CD
Dia.A
1 in.
B
C
D
Dia.A
3/4 1 in.3/4
All dimensions in inches.Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.
Grs dimensional data n in stock sizes include birdscreen
Sizes 8-24 Sizes 30-48
For complete product information contact your Brucker sales representative.
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• Aluminum curb cap with prepunched
mounting holes• Recommended roof opening dimension is
at least 2.5 in. larger than the damper size
OPTiOnS AnD ACCESSORiES• Gravity and motorized dampers • Galvanized roof curbs
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 27
GREE
NHEC
K
Centrifugal Utility Fans - SFB
sfB PerformanCe data - in stoCk
OPTiOnS AnD ACCESSORiES
• Vibration isolators• Weatherhood• Belt guard
DISCHARGE POSITIONS(Viewed from Drive Side)
SFB STAnDARD COnSTRUCTiOn FEATURES
HOUSING:• Heavy gauge steel housing with Lock-seam construction• Unit support angles with prepunched mounting holes• Adjustable motor plate• Corrosion resistant fasteners• Entire unit is phosphatized and coated.
BEARINGS, SHAFT, AND WHEEL:• Heavy duty lubricatable, self-aligning ball bearing pillow blocks• Polished, solid steel shafts• Forward curved fan wheel
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com28
sWB standard Condensed PerformanCe & dimensional data
All dimensions in inches.Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
HOUSING:• Heavy gauge steel housing with Lock-seam construction• Unit support angles with prepunched mounting holes• Adjustable motor plate• Corrosion resistant fasteners• Entire unit is phosphatized and coated.
BEARINGS, SHAFT, AND WHEEL:• Heavy duty lubricatable, self-aligning ball bearing pillow blocks• Polished, solid steel shafts• Backward inlclined steel wheel
OPTiOnS AnD ACCESSORiES
• Vibration isolators• Weatherhood• Belt guard
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 29
GREE
NHEC
K
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
STAnDARD COnSTRUCTiOn FEATURES• Galvanized steel• UL/cUL 555C Listed• Fabricated to your size
requirements• Rectangular, round or curtain
type
STAnDARD COnSTRUCTiOn FEATURES• G - UL 555 Classified (1 1/2
hour fire resistance rating)• For use in walls, floor, and
partions w/fire resistance ratings less than 3 hours
• Type A curtain (blades in air stream)
• Vertical or horizontal• Spring loaded• 165 degree fusible link
STAnDARD COnSTRUCTiOn FEATURES• UL 555 Classified (1 1/2
hour fire resistance rating)• For use in walls, floor, and
partions w/fire resistance ratings less than 3 hours
• True round (blades in air stream)
• Vertical or horizontal• 13.625" length • 165 degree fusible link
OPTiOnS AnD ACCESSORiES• Thermal blankets (1 in. mineral wool or
quilted ceramic) - 24 in. x 24 in.
Ceiling Radiation DampersGreenheck’s ceiling radiation dampers are qualified under UL/cUL 555C, Standard for Ceiling Dampers. Ceiling radiation dampers are designed to function as a heat barrier in duct outlets penetrating fire resistive membrane ceilings. These dampers may be used in lieu of hinged door type dampers, in ceiling designs listed in the UL/cUL Fire Resistance Directory which allow penetrations.
dfd-150
Dynamic Fire Dampers - DFD-150/DFDR-510
WIDTH (INCHES)
HEIGHT (INCHES) 6 8 10 12 14 16 18 20 24
4 X X X X6 X X X X X X X X X8 X X X X X X X X10 X X X X X X X12 X X X X X X14 X X X X X16 X X X X18 X X X20 X X24 X
SIZES (INCHES)
468
10121416182024
dfdr-510 (roUnd)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 31
GREE
NHEC
K
Backdraft Dampers, Curbs and Equipment Supports
MODEL FLANGE V H E I MOTORPACKWD-100 NONE X X XWD-200 NONE X X X XWD-320 YES X X XWD-323 YES X XWD-330 NONE X X XWD-410 NONE X X
Greenheck’s backdraft dampers are used in systems to allow airflowin one direction and prevent airflow in the opposite direction.Material=Galvanized
Roof curbs construction feature is Galv Steel, rigidfiberglass insulation to minimize condensation andreduce sound. Suited for surface mounting on insulatedroof decks. It is welded with a 2" mounting flange.
Model: RH-3
Backdraft Dampers, Curbsand Equipment Supports
Equipment supports are designed for use on both insulatedand non-insulated flat roof decks. They are constructed ofgalvanized steel.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com32
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 33
ABB
ABB
Variable Frequency Drives 34
Model UH Base Drive 35
Model VCR Vertical Bypass with Circuit Breaker 36
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com34
Variable Frequency Drives
desCriPtion
The ACH550 series is a microprocessor based Pulse Width Modulated (PWM) adjustable speed AC drive The ACH550 drive takes advantage of sophisticated microprocessor control and advanced IGBT powerswitching technology to deliver high-performance con-trol of AC motors for a wide range of HVAC applications
With drives ranging from 1 to 550 HP, the ACH550 series features a universal full graphic interface that “speaks" to the operator in plain English phrases, great-ly simplifying set-up, operation, and fault diagnosis The ACH550 is also programmable in fourteen other languages
Each ACH550 drive comes equipped with an extensive library of pre-programmed HVAC application macros which, at a touch of a button, allow rapid configuration of inputs, outputs, and performance parameters for spe-cific HVAC applications to maximize convenience and minimize start-up time The ACH550 series can handle the most demanding commercial applications in an ef-ficient, dependable, and economic manner
featUresmodels UH & vCr• ABB Microprocessor base Pulse Width Modulated
(PWM) Adjustable frequency AC drives• Modbus, Johnson, Siemens, and BACnet Standard• Integral 5% input line impedance• Built-in first environmental EMI/RFI filter• Built in Real Time Clock• Fault Logger• Built in Assistants for Start-up, Maintenance, and Diag-
nostics• Extremely User Friendly Keypad• Hand, Off, Auto and speed pot all on Keypad• UL/Nema 1 Enclosure
additional featUres model vCr• Vertical Bypass on 480V, 1-50 HP• Fast Acting Semi Conductor fuses in front of VFD• Drive & Bypass contactors• Circuit breaker disconnect• Service switch• No Contactor Chatter• Serial Communications capability even in Bypass• Single Phase protection for motor even in Bypass• Electronic motor overload relay with external reset• 2 wire start/stop dry contact closure• Damper control circuit
Model VcrBase drive w/VerticalBypass and circuit Breaker
Model uhBase drive
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 35
ABB
Model UH- Base Drive
Model uh - Base driveseleCtion CHart - stoCk sizes
Outside dimensions - r1...r4Outside dimensions depend on frame size and enclosure type, as defined below.
Notes: 1 AC Motor Data is per National Electical Code Table 430 250 for typical motors used in most applications and is provided as typical data only DC motor data is per typcial industry standards Actual motor data may vary
Ul tyPe 1 - oUtside dimensionsref. r1 r2 r3 r4
mm in mm in mm in mm in
W 125 4 9 125 4 9 203 8 0 203 8 0
h 330 13 0 430 16 9 490 19 2 596 23 4
h3 369 14 5 469 18 5 583 23 0 689 27 1
d 212 8 3 222 8 7 231 9 1 262 10 3
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 37
BROA
N
BROAN
Bath Fans 38
Ventilation Fans - Ultra Silent™ 39
Combination Units 40
Wall Heaters 41
LoSone Ventilators 42
Broan Controls 43
Roof and Wall Caps 44
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com38
Bath Fans
Premium Fans
• Centrifugal blower wheel and 4-pole motor deliver high exhaust capacity at low sound levels.
• All-new, designer styled white polymeric grille complements virtually any decor.
• Torsion spring grille mounting – no tools necessary.
• Metal grille kits (available separately)
Vertical Discharge
Model 673 Ceiling Fan 60 CFM 4.0 Sones.
• Durable polymeric fan blade.
• Spin-on, white polymeric grille.
• Galvanized steel housing.
• Double strength steel mounting brackets with keyhole slots for fast installation.
Deluxe Fans
• Durable Broan-designed blower wheel.
• Torsion spring grille mounting – no tools necessary.
• Compact housing fits easily between ceiling joists or wall studs.
• Double strength steel mounting flanges with keyhole slots for fast installation.
• Metal grille kits (available separately)
Economy Fans
• Torsion spring grille mounting – no tools necessary.
• Compact housing fits easily between ceiling joists or wall studs.
• Covered by U.S. and foreign patents.
• Metal grille kits (available separately)
Model 676 Ceiling Fan110 CFM 4.0 Sones.
Model 684 Ceiling Fan80 CFM 2.5 Sones.
Model 671 Ceiling/Wall Fan70 CFM 3.0 Sones.
Model 670 Ceiling/Wall FanIndustry Exclusive50 CFM 1.5 Sones.
Model 689 Ceiling/Wall Fan60 CFM 3.5 Sones.
Model 688 Ceiling/Wall Fan50 CFM 2.0 Sones.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 39
BROA
N
Ventilation Fans – Ultra Silent™
Qtr fan featUresNearly silent operation 1 0 to 1 5 sones• 100 CFM to 150 CFM• HVI Certified• Motor engineered for continuous operation• UL Listed for use over bathtubs or showers
when connected to a GFCI protected branch circuit• Fits 2" x 8" ceiling construction
Energy star fans use 65% less energy, on average, than standard models and may qualify for local utility rebates.
Fan Model cFM sones Bath sq. Ft. ducting
Qtr080 80 1 0 75 4"
Qtr110 110 1 5 100 4"
MODELS IN STOCK
Motordor ®
Model 12C Motordor® 10” Wall FanIndustry Exclusive
•380 CFM 5.5 Sones.
•Housing features foam-insulateddoor for energy efficiency.
•Separate motor opens door whenfan is turned on, closes door whenunit is turned off.
•Housing adjusts to fit walls from41⁄2” to 91⁄2” thick.
Wall/Ceiling Mount
Model 502 10” Side Discharge Fan
•270 CFM 7.0 Sones.
•Installs easily between ceiling joistsor wall studs.
•Built-in damper prevents backdrafts.
•Fits 31⁄4” x 10” duct.
Vertical Discharge
Model 504 10” Vertical DischargeFan
•350 CFM 6.5 Sones.
•Installs easily between ceilingjoists.
•Fits 10” round duct – use Model472 transition/damper (availableseparately) for 8” round duct
Model 503 8” Side Discharge Fan
•160 CFM 5.0 Sones.
•All other features same as Model502.
Model 505 8” Vertical Discharge Fan
•180 CFM 5.0 Sones.
•Installs easily between ceiling joists.
•Housing features built-in backdraftdamper.
•81⁄4” diameter housing.
•Fits 8” round duct.
•All other features same as Model 504.
Room To Room
•Easy interior wall installation.
•Permanently lubricated motor.
•High-strength, reinforced polymeric fan blade.
•Two attractive white polymeric grillescan be painted to match decor.
Model 511 8” Room To Room Fan
•180 CFM 3.5 Sones.
•Built-in variable speed control.
•Housing adjusts to fit walls from 3”to 51⁄2” thick.
Utility Ventilators
Utility Ventilators
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com40
BROA
N
(847) 437-9690 (309) 691-5160 (219) 546-5556Elk Grove Village Peoria South Bend
Model 696 Fan/Light
•100 CFM 4.0 Sones.
•Does not include heater.
•Designer styled white polymeric grille complements virtuallyany decor.
•Bright 100-watt light capacity (bulb not included).
•Housing lined with 1⁄2” acoustic insulation.
•15 amp circuit acceptable.
•Type IC.
Model 657 Fan/Light
• 70 CFM 3.5 Sones.
• Does not include heater.
• Type IC.
• UL listed for use over bathtubs and showers whenconnected to GFCI-protected branch circuit.
Heater/Fan/Light Combination Units
•Two blower wheels, eachpowered by its own permanently lubricated plug-in motor, quietly deliver high-efficiency performance.
•1300-watt heater for fast, even heat distribution.
•Built-in damper preventsbackdrafts and eliminates metallicclatter.
•Adjustable, slotted mountingbrackets span up to 24” for easyinstallation.
•Polymeric 4” round duct featuresa 2” long tapered sleeve for easy, positive ducting.
Model 655 Heater/Fan/Light
•70 CFM 3.5 Sones.
•Designer styled white polymericgrille complements virtually anydecor.
•Fan and heater functionindependently or together.
•Bright 100-watt light capacity (bulb not included).
•20-amp circuit required.
•Type IC.
•Use with Model 66, three-function control (availableseparately)
Models 655657696
Combination UnitsCombination Units
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 41
BROA
N
Fan/Light Combination Units.
Quality Broan features and easy installationmake this an extremely popular series.
•All-new, designer styled white polymeric grillecomplements virtually any decor.
•Plug-in, permanently lubricated motor.
•Efficient polymeric fan impeller.
•Mounting ears offer quick, sturdy installation.
•UL listed for use over bathtubs and showers when connected to a GFCI-protected branch circuit.
•Polymeric duct connectors with taperedsleeves for easier, positive ducting.
Model 161 One-Bulb Heater/Fan
•70 CFM 3.5 Sones.
•Overall housing dimensions 6” x 121⁄4” x 81⁄8”.
•UL listed for 75°wiring (retrofits).
•Not Type IC.
Heater/Fan units also include Broan quality ventilating features.
Fan-Forced Wall heatersConvenient Rugged Reliable Our sturdy 24-gauge steel housing mounts eas-ily between studs in any standard wall, or can be surface mounted where needed A housing mask prevents construction damage to roughed-in units, and protects the housing and its ele-ment And a snap-out wiring cover allows wiring away from tight corners
Model 174• Factory wired for 1500W at 120 V AC–easily
converts to 750W at 120V AC or 1500W at 240V AC
MODEL WATTS VOLTS AMPS
174
750W-1500W 120 6.25/12.5
1125W 208 5.41
1500W 240 6.25
surface Mount kit - Model 84• Includes all hardware for surface mounting of
Broan Comfort-Flo heaters• White enameled, steel enclosure matches
grille color• Measure 12-3/8"W x 9-5/8"H x 3-7/8"D
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com42
12 1/4”(311.2 mm)21 1/2”
(546.1 mm)
11 3/4”(298.4 mm)
4 1/2” X 18 1/2”(114.3 mm X 469.9 mm)
DUCT CONNECTOR
LoSone Ventilators
ceiling Mount Ventilators – 100, 150, 200, 150 & 300 cFMSinglee, impact resistant centrifufal blower wheel driven by a low RPM motor 121/4" x 121/2" x 113/4" high housing Low profile white polymeric grille (14" x 14") or sturdy, low profile metal grille finished with painted white enamel (14" x 14") Built-in backdraft damper Discharges horizontally or vertically through 6" or 8" round duct
ceiling Mount Ventilators – 400, 500 & 700 cFMTwo, impact resistant centrifugal blower wheels driven by low RPM motor 211/2" x 211/4" x 113/4" high housing Sturdy, low profile metal grille finished with painted white enamel (21" x 14") Discharges horizontally or verticallythrough 41/2" x 181/2" duct connector
ceiling Mount Ventilators – 900Single, impact resistant centrifugal blower wheel driven by low RPM motor 22" x 18" x 18" high housing Sturdy,low profile metal grille finished with painted white enamel (21" x 14") Discharges horizontally or verticallythrough 8" x 12" duct connector
• Positive on/off action – dial for variable selection of air speeds and sound levels
• Built-in radio noise suppressor
• Controls available in White (W) or Ivory (V)
Model 72V, 72W (6-Amp)*
• 120V, 6 amps
• Other features same as model 57
Three-Function Controls
Model 66W, 66V
• Three independent, 120V, 15amp rocker switches (20 amp total)
• Fits single-gang box
• Controls available in White (W) or Ivory (V)
Decorator Time Controls
Model 59V (60 Minute)
• 120V, 20 amps; 240V, 10 amps
• Operate continuously or for any set period – Model 59V – up to 60 minutes
Model 61V , 61W (15 Minute)
• Operate for any set period up to 15 minutes (no “continuous on" position)
• Other features same as model 59
• Controls available in White (W) or Ivory (V)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com44
Roof and Wall Caps
Model 611 Roof Cap
• For flat roof installation
• Aluminum natural finish
• For up to 8" round duct
Model 634 Roof Cap
• For 31⁄4" x 10" or up to 8" round duct
• Built-in backdraft damper and bird screen
• Steel baked black enamel finish
Model 644 Roof Cap
• Same as Model 634 except for aluminum, natural finish
Model 636 Roof Cap
• For 3" or 4" round duct
• Built-in backdraft damper and bird screen
• Steel baked black enamel finish
Model 646 Louvered Wall Cap
• For 6" duct
•White polymeric
Model 430 Short Eave Elbow
• For 31⁄4" x 10" duct
• Includes backdraft damper and grille
Model 431 Long Eave Elbow
• For 31⁄4" x 10" duct
• Includes backdraft damper and grille
Model 639 Wall Cap• For 31⁄4" x 10" duct • Spring-loaded backdraft damper • Built in bird screen • Steel baked black enamel finish
Model 649 Wall Cap• Same as Model 639 except
aluminum, natural finish
Model 640 Wall Cap• For 3" round duct • Built-in bird screen – no damper • Steel baked black enamel finish
Model 642 Wall Cap• For 3" or 4" duct • 4" to 3" transition included • Built-in damper • Aluminum, natural finish
Model 641 & 843BL Wall Cap• For 6" round duct • Built-in backdraft damper and
bird screen • Aluminum, natural
finish (641) or black finish (843BL)
Model 647 Wall Cap• For 7" round duct • Other features same
as Model 641
Model 643 Wall Cap• For 8" round duct • Aluminum, natural finish
Model 441 Wall Cap• For 10" round duct • Aluminum, natural finish
Model 613 Wall Cap• For 12" round duct • Built-in backdraft damper
and bird screen• Aluminum, natural finish
Model441
See Greenheck Section Page 17-18 for additional roof and wall accessories.
Model613
Model643
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 45
Pric
e
Price Industries
Fixed Blade Return Grilles and Registers Model 530 and 530D 46
Filter Return Grilles Model 530FF 47
Light Shields 47
Round Diffusers Model RCDE 49
Door/Transfer Grilles Model STG1 50
Double Deflection Supply Grilles Model 520D & Single Deflection Supply Grilles Model VM 51
High Capacity Drum Louvers Model HCD1D 56
Square Cone Diffusers Model SCD/Plaster Frames 57
Square Cone Diffusers Model SCDA Adjustable Air Pattern/Plaster Frames 59
Square Plaque Diffusers Model SPD/Plaster Frames 61
Linear Slot Diffuser Model SDS 63
Linear Slot Diffuser Plenums Model SDBI 64
T-Bar Supply Diffusers Model TBDI4 65
Perforated Supply Diffusers Model PDF/PDFE 67
Perforated Return Diffusers Model PDDR/PDDRE (Matching Return for PDF/PDFE) 70
Dampers 72
Spiral Duct Mount Grilles Model SDG 73
Louvered Face Diffusers Model SMD 73
Egg Crate Grilles Model 80/Plaster Frames 75
Round Neck Adaptors Model SR3 77
Single Duct – Controller Type SPV, SDV, SEV Series 78
Control Sequence Model SPV/SEV 82
VAV Diffuser Varitherm® Model VPD-HC 83
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com46
Fixed Blade Return Grilles and RegistersModel 530 and 530D
36 X 436 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 648 X 1048 X 1248 X 1848 X 2048 X 2448 X 3048 X 3648 X 48
FEATURES
• All steel construction.
• Opposed blade damper, steel
• Surface mountng w/screw holes.
• B12 standard finish.
• Blade with L orientation.Model 530 and 530DReturn Air Grille Fixed Louvers,
45° Deflection, 3/4" Blade Spacing
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1212 X 1812 X 2414 X 414 X 614 X 814 X 1014 X 1214 X 14
MODEL 530 (NO DAMPER)16 X 616 X 816 X 1016 X 1216 X 1416 X 1618 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1818 X 2418 X 3020 X 620 X 820 X 1020 X 1220 X 1420 X 1620 X 1820 X 20
20 X 2424 X 424 X 624 X 8
24 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2424 X 3024 X 3630 X 630 X 8
30 X 1030 X 1230 X 1430 X 1630 X 1830 X 2030 X 2430 X 30
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 10
MODEL 530D (WITH DAMPER)14 X 1214 X 1416 X 616 X 816 X 1016 X 1216 X 1618 X 618 X 818 X 1018 X 1218 X 1618 X 1820 X 620 X 820 X 1020 X 1220 X 14
20 X 1620 X 1820 X 2024 X 624 X 8
24 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2430 X 630 X 8
30 X 1030 X 1230 X 1430 X 16
30 X 1830 X 2030 X 2436 X 636 X 836 X 1036 X 1236 X 1636 X 1836 X 2036 X 2436 X 3048 X 1248 X 2448 X 36
22 X 422 X 622 X 8
22 X 1046 X 22
T-BAR LAYIN SIZES
22 X 622 X 1022 X 2246 X 22
530TBNo Damper
530DTBWith Damper
6 X 46 X 68 X 48 X 68 X 810 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 1014 X 1214 X 14
16 X 616 X 816 X 1016 X 1216 X 1618 X 418 X 518 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1820 X 620 X 820 X 1020 X 1220 X 1420 X 16
20 X 1820 X 2024 X 624 X 824 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2426 X 1230 X 630 X 830 X 1030 X 1230 X 1430 X 1630 X 1830 X 20
30 X 24 30 X 3032 X 836 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 1248 X 2448 X 36
6 X 46 X 68 X 48 X 68 X 810 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1212 X 1812 X 2414 X 414 X 614 X 814 X 1014 X 1214 X 1416 X 616 X 8
16 X 1016 X 1216 X 1416 X 1618 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1818 X 2418 X 3018 X 3620 X 420 X 620 X 420 X 820 X 1020 X 1220 X 1420 X 1620 X 1820 X 2020 X 24
22 X 2224 X 424 X 624 X 824 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2424 X 3024 X 3630 X 630 X 830 X 1030 X 1230 X 1430 X 1630 X 1830 X 2030 X 2430 X 3034 X 1634 X 20
36 X 436 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 648 X 848 X 1048 X 1248 X 1448 X 1648 X 1848 X 2048 X 2448 X 3048 X 3648 X 48
model 530d (WitH damPer)stoCk sizes
model 530 (no damPer)stoCk sizes
t-Bar layin - stoCk sizes
530tBno damper
530dtBWith damper
10 X 1022 X 422 X 622 X 822 X 1022 X 2246 X 22
22 X 622 X 1022 X 2246 X 22
FEATURES• All steel construction.• Opposed blade damper, steel• Surface mountng w/screw holes.• B12 standard finish.• Blade with L orientation.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 47
Pric
e
Filter Return Grilles Model 530FF
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Border
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Border
model 530ffstoCk sizes
t-Bar layinstoCk sizes
liGHt sHieldstoCk sizes
24 X 12–20 X 8
24 X 24–20 X 20
22 X 22
20 X 1620 X 2020 X 1220 X 1624 X 1224 X 1624 X 2425 X 1625 X 20
FEATURES• Steel construction.• Surface mount (or)• Lay-in mounting, 24 X 24 module with
20 X 20 filter size.• B12 standard finish.
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Bordert-Bar Border
Light Shields
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com48
Return Grilles Model 530, 530D & 530FF
PERFORMAnCE DATA
44
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
6 X 6
7 X 6
8 X 6
10 X 6
12 X 6
8 X 8
14 X 6
10 X 8
16 X 6
18 X 6
12 X 8
20 X 6
14 X 8
22 X 6
16 X 8
26 X 6
18 X 8
30 X 6
22 X 8
20 X 10
16 X 12
22 X 10
18 X 12
26 X 10
22 X 12
30 X 10
24 X 12
34 X 10
28 X 12
32 X 12
28 X 14
36 X 12
30 X 14
34 X 14
30 X 16
40 X 14
34 X 16
40 X 16
36 X 18
44 X 16
40 X 18
48 X 18
42 X 20
52 X 18
48 X 20
NC 20
0.15
0.18
0.22
0.26
0.30
0.34
0.39
0.46
0.52
0.60
0.69
0.81
0.91
1.07
1.18
1.34
1.60
1.80
2.08
2.45
2.78
3.11
3.61
4.29
4.65
5.58
6.25
200.002.011
GRILLES ANDREGISTERS
NECK AREA SQ. FT.NOMINAL SIZE
CORE VELOCITYPRESSURE
NEGATIVE SP
30
-
36
-
44
-
52
-
60
-
68
-
78
-
92
-
104
-
120
-
138
-
162
-
182
-
214
-
236
-
268
-
320
-
360
-
416
-
490
-
556
-
622
-
722
-
858
-
930
-
1116
-
1250
-
45
-
54
-
66
-
78
-
90
-
102
-
117
-
138
-
156
-
180
-
207
-
243
-
273
-
321
-
354
-
402
-
480
-
540
-
624
-
735
-
834
-
933
-
1083
-
1287
-
1395
-
1674
15
1875
15
60
-
72
-
88
-
104
-
120
15
136
15
156
15
184
16
208
16
240
16
276
17
324
17
364
18
428
18
472
18
536
19
640
19
720
20
832
20
980
20
1112
21
1244
21
1444
22
1716
22
1860
22
2232
23
2500
23
75
19
90
19
110
20
130
20
150
21
170
21
195
21
230
22
260
22
300
23
345
23
405
23
455
24
535
24
590
25
670
25
800
25
900
26
1040
26
1225
27
1390
27
1555
27
1805
28
2145
28
2325
28
2790
29
3125
29
90
24
108
24
132
25
156
25
180
26
204
26
234
26
276
27
312
27
360
28
414
28
486
28
546
29
642
29
708
29
804
30
960
30
1080
31
1248
31
1470
32
1668
32
1866
32
2166
33
2574
33
2790
33
3348
34
3750
34
105
28
126
28
154
29
182
29
210
30
238
30
273
31
322
31
364
31
420
32
483
32
567
33
637
33
749
33
826
34
938
34
1120
35
1260
35
1456
35
1715
36
1946
36
2177
36
2527
37
3003
37
3255
38
3906
38
4375
38
120
32
144
32
176
33
208
33
240
33
272
34
312
34
368
35
416
35
480
35
552
36
648
36
728
37
856
37
944
37
1072
38
1280
38
1440
39
1664
39
1960
39
2224
40
2488
40
2888
41
3432
41
3720
41
4464
42
5000
42
135
35
162
35
198
36
234
36
270
37
306
37
351
37
414
38
468
38
540
39
621
39
729
40
819
40
963
40
1062
41
1206
41
1440
41
1620
42
1872
42
2205
43
2502
43
2799
43
3249
44
3861
44
4185
44
5022
45
5625
45
150
38
180
38
220
39
260
39
300
40
340
40
390
40
460
41
520
41
600
42
690
42
810
42
910
43
1070
43
1180
43
1340
44
1600
44
1800
45
2080
45
2450
46
2780
46
3110
46
3610
47
4290
47
4650
47
5580
48
6250
48
165
40
198
41
242
41
286
42
330
42
374
43
429
43
506
43
572
44
660
44
759
45
891
45
1001
45
1177
46
1298
46
1474
46
1760
47
1980
47
2288
48
2695
48
3058
48
3421
49
3971
49
4719
50
5115
50
6138
50
6875
51
7 X 4
6 X 5
8 X 4
7 X 5
10 X 4
8 X 5
12 X 4
10 X 5
14 X 4
16 X 4
12 X 5
18 X 4
14 X 5
20 X 4
16 X 5
24 X 4
18 X 5
28 X 4
20 X 5
30 X 4
24 X 5
36 X 4
28 X 5
40 X 4
32 X 5
42 X 4
36 X 5
34 X 6
24 X 8
38 X 6
28 X 8
44 X 6
32 X 8
50 X 6
36 X 8
58 X 6
42 X 8
50 X 8
38 X 10
56 X 8
44 X 10
48 X 10
40 X 12
56 X 10
48 X 12
56 X 12
48 X 14
60 X 12
50 X 14
60 X 14
54 X 16
72 X 14
60 X 16
10 X 10
12 X 10
14 X 10
16 X 10
12 X 12
18 X 10
14 X 12
14 X 14
16 X 14
18 X 14
16 X 16
20 X 14
18 X 16
24 X 14
20 X 16
24 X 16
20 X 18
26 X 16
24 X 18
26 X 18
24 X 20
30 X 18
28 X 20
32 X 20
30 X 22
36 X 20
32 X 22
38 X 22
36 X 24
40 X 24
32 X 30
Louvered Face Return Performance Data Models 530, 530FF
300.006.025
400.010.044
500.016.069
600.022.100
700.031.136
800.040.177
900.050.224
1000.062.277
1100.075.335
30
NC40
NC50
NC 20 30 40 50
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 49
Pric
e
FEATURES
• Steel construction.
• Two position adjustable pattern.
• Surface mounting.
• B12 standard finish.
• Auxiliary dampers available (Model VCR8E)
6 111/8 61/2 6 13/4 111/8
8 143/4 81/2 8 21/8 11/2
10 181/4 101/2 10 27/8 21/8
12 22 121/2 12 31/8 23/8
14 26 141/2 14 33/8 25/8
16 29 161/2 16 4 31/4
18 321/2 181/2 18 43/4 37/8
NominalSize A B D E F
DIMENSIONAL DATA
NC 20
6
8
10
12
14
16
18
400.010
500.016
600.023
700.031
800.040
900.051
1000.063
1200.090
1400.122
1600.160Size
Neck Velocity fpmVelocity Pressure in w.g.
.026
80
2-2-4
-
.033
140
2-4-8
-
.027
220
3-4-7
-
.026
315
3-5-8
-
.038
425
4-6-10
11
.033
560
5-7-11
16
.030
710
5-7-12
.041
100
2-3-5
-
.052
175
3-4-7
15
.043
270
3-5-8
11
.042
390
4-6-10
11
.061
530
5-8-12
18
.053
700
6-9-14
16
.048
885
6-9-15
15
.059
120
2-4-6
14
.075
210
4-5-9
21
.062
330
4-6-10
17
.060
470
5-7-12
17
.087
635
6-9-15
23
.076
840
7-10-16
22
.069
1060
7-11-18
21
.079
140
3-4-7
19
.101
245
4-6-10
26
.084
380
5-7-11
21
.081
550
6-8-13
22
.118
745
7-11-17
28
.102
980
8-12-19
27
.093
1240
9-13-21
26
.102
160
3-5-8
23
.130
280
5-7-11
31
.108
435
5-8-13
26
.105
630
6-10-15
26
.152
850
8-12-20
32
.132
1120
9-14-22
31
.120
1420
10-15-24
30
.130
180
4-5-9
26
.166
315
5-8-13
34
.138
490
6-9-15
30
.135
705
7-11-17
30
.194
955
9-14-22
36
.168
1260
10-15-24
35
.153
1590
11-17-27
34
.161
200
4-6-10
30
.205
350
6-9-14
37
.170
545
7-10-16
33
.166
785
8-12-19
33
.240
1060
10-15-24
40
.208
1400
11-17-27
39
.189
1770
12-19-30
37
.230
235
5-7-11
35
.292
420
7-11-17
44
.243
655
8-12-20
39
.236
940
10-14-23
39
.342
1270
12-18-29
46
.297
1680
14-20-33
44
.270
2120
15-22-36
43
.311
275
6-8-13
40
.397
490
8-13-20
48
.329
765
10-14-23
44
.320
1100
11-17-23
45
.465
1490
14-21-34
51
.403
1960
16-24-38
49
.366
2480
17-26-42
48
.408
315
6-10-15
44
.520
560
10-14-23
53
.432
870
11-16-26
48
.420
1255
12-19-31
49
.608
1695
16-24-39
55
.528
2240
18-27-43
53
.480
2830
20-30-48
52
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
30 40
50
NC 20 30 40 50
Performance Data
Round Diffusers Model RCDE
PERFORMAnCE DATA - in STOCK
dimensional data
FEATURES• Steel construction.• Two position adjustable pattern.• Surface mounting.• B12 standard finish.• Auxiliary dampers available (Model VCR8E)
RCDE Air Pattern
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com50
Door/Transfer Grilles Model STG1Steel Construction
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 51
Pric
e16 X 416 X 616 X 8
16 X 1016 X 1218 X 418 X 618 X 8
18 X 1018 X 12
FEATURES
• All steel construction.
• Opposed blade damper, steel.
• Surface mounting with screw holes.
• B12 standard finish, black damper.
• Front blade in vertical orientation.
Model 520DDouble Deflection 3/4" Blade Spacing
6 X 46 X 68 X 48 X 58 X 68 X 810 X 410 X 510 X 610 X 8
10 X 1012 X 412 X 612 X 8
12 X 1012 X 1214 X 614 X 8
14 X 1014 X 1214 X 14
STOCKED SIZES16 X 416 X 516 X 616 X 8
16 X 1016 X 1216 X 1618 X 418 X 618 X 8
18 X 1018 X 1218 X 1820 X 420 X 620 X 8
20 X 1020 X 12
24 X 424 X 624 X 824 X 1024 X 1224 X 1424 X 2430 X 430 X 630 X 830 X 1030 X 1236 X 436 X 636 X 836 X 1036 X 1236 X 2048 X 648 X 848 X 1048 X 12
Model VM(Single Deflection)FEATURES
• All aluminum construction.
• Multishutter damper.
• Surface mounting with screw holes.
• Off-white finish.
• Blade in vertical orientation.
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 610 X 8
10 X 10
12 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 1014 X 1214 X 14
20 X 620 X 8
20 X 1020 X 1220 X 1424 X 624 X 8
24 X 1024 X 12
Detail ARollformed
Deflecting Blade
Detail BMulti-Shutter
Blade
D =
Nom
inal
Duc
t Siz
e
Over
all =
D +
13 /4"
(44)
Open
ing
= D
- 3 /4" (1
9)
3/4"(19)
1/4"(6)
11/4"(32)
2"(51)VCS3
OpposedBlade
DamperAttached
Double Deflection Supply Grilles Model 520D& Single Deflection Supply Grilles Model VM
6 X 46 X 68 X 48 X 68 X 810 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 4 14 X 614 X 814 X 1014 X 1214 X 1416 X 416 X 5
16 X 616 X 816 X 1016 X 1216 X 1618 X 418 X 618 X 818 X 1018 X 1218 X 1820 X 420 X 620 X 820 X 1020 X 1220 X 1420 X 2022 X 624 X 424 X 624 X 824 X 10
24 X 1224 X 1424 X 1624 X 1824 X 2430 X 430 X 630 X 830 X 1030 X 1236 X 436 X 636 X 836 X 1036 X 1230 X 1630 X 1836 X 2048 X 648 X 848 X 1048 X 12
t-Bar layin sizes22 X 622 X 8
22 X 1022 X 22
model 520dstoCk sizes
t-Bar layin sizes22 X 4 22 X 6
8 X 68 X 810 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1214 X 414 X 6
14 X 814 X 1014 X 1214 X 1416 X 416 X 616 X 816 X 1016 X 1216 X 1418 X 618 X 8
18 X 1018 X 1220 X 620 X 820 X 1020 X 12 20 X 14 24 X 624 X 824 X 1024 X 12
FEATURES• All steel construction.• Opposed blade damper, steel.• Surface mounting with screw holes.• B12 standard finish, black damper.• Front blade in vertical orientation.
FEATURES• All aluminum construction.• Multishutter damper.• Surface mounting with screw holes.• Off-white finish.• Blade in vertical orientation.
model vm stoCk sizes
Model 520D Double Deflection 3/4" Blade Spacing
Model VM (Single Deflection)
Gril
le F
ram
e O
vera
ll =
D +
13 /4"
(45)
Gril
le F
ram
e O
vera
ll =
D +
13 /4"
(45)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com52
Supply Grilles Models 520D & VM
NC 20
Ac=0.15 ft.2
7 X 4
6 X 5
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
80
-
5-8-14
4-6-11
3-4-7
70
-
6-8-15
5-6-12
3-4-8
90
-
7-10-17
6-8-14
3-5-9
105
-
7-11-19
6-9-15
4-5-9
120
-
8-11-20
6-9-16
4-6-10
135
-
8-12-21
6-10-17
4-6-11
155
-
9-13-23
7-10-18
4-6-11
.038
.045
.067
75
-
7-10-16
6-8-13
3-5-8
90
-
7-11-17
6-9-14
4-5-9
110
-
8-12-19
6-10-15
4-6-10
130
-
9-13-21
7-10-17
4-7-10
150
-
9-14-22
7-11-18
5-7-11
170
-
10-15-24
8-12-19
5-8-12
195
-
11-16-25
9-13-20
5-8-13
.052
.063
.093
90
-
8-12-17
6-10-14
4-6-9
110
-
9-13-19
7-10-15
4-7-10
130
-
9-15-21
7-12-17
5-7-10
155
13
10-16-23
8-13-18
5-8-11
180
13
11-17-24
9-14-19
6-8-12
205
14
12-19-26
10-15-21
6-9-13
235
14
13-19-28
10-15-22
7-10-14
.071
.085
.126
105
15
9-13-19
7-10-15
5-7-9
125
16
10-15-20
8-12-16
5-7-10
155
17
11-16-23
9-13-18
6-8-11
180
17
12-17-24
10-14-19
6-9-12
210
18
13-19-26
10-15-21
7-9-13
240
19
14-20-28
11-16-22
7-10-14
275
19
15-22-30
12-18-24
8-11-15
.094
.114
.168
120
19
11-14-20
9-11-16
5-7-10
145
20
11-16-22
9-13-18
6-8-11
175
21
13-17-24
10-14-19
6-9-12
210
21
14-19-26
11-15-21
7-9-13
240
22
15-20-28
12-16-22
8-10-14
270
23
16-22-30
13-18-24
8-11-15
310
23
17-23-32
14-18-26
9-12-16
.146
.176
.261
150
26
13-16-22
10-13-18
6-8-11
180
27
14-17-24
11-14-19
7-9-12
220
27
16-19-27
13-15-22
8-10-13
260
28
17-21-29
14-17-23
8-11-15
300
29
18-23-31
14-18-25
9-11-16
340
29
20-24-33
16-19-26
10-12-17
390
30
21-26-36
17-21-29
11-13-18
.212
.256
.379
180
31
14-17-24
11-14-19
7-9-12
215
32
15-19-26
12-15-21
8-10-13
265
33
17-21-29
14-17-23
9-11-15
310
34
19-23-32
15-18-26
9-12-16
360
34
20-25-34
16-20-27
10-12-17
410
35
22-26-37
18-21-30
11-13-18
470
35
23-27-40
18-22-32
12-14-20
.287
.347
.514
210
36
15-19-26
12-15-21
8-9-13
250
37
17-21-29
14-17-23
8-10-14
310
38
19-23-32
15-18-26
9-12-16
365
38
20-25-35
16-20-28
10-13-17
420
39
22-27-37
18-22-30
11-13-19
475
40
23-28-40
18-22-32
12-14-20
545
40
25-30-42
20-24-34
12-15-21
.374
.452
.669
240
40
16-20-28
13-16-22
8-10-14
290
41
18-22-31
14-18-25
9-11-15
350
42
20-25-34
16-20-27
10-12-17
415
42
22-26-37
18-21-30
11-13-18
480
43
24-29-40
19-23-32
12-14-20
545
44
25-30-42
20-24-34
12-15-21
625
44
27-33-45
22-26-36
13-16-23
.475
.574
.850
270
44
17-22-30
14-18-24
9-11-15
325
45
19-24-33
15-19-26
10-12-16
395
45
21-26-36
17-21-29
11-13-18
470
46
23-27-40
18-22-32
12-14-20
540
47
25-30-42
20-24-34
12-15-21
610
47
26-32-45
21-26-36
13-16-22
700
48
28-35-48
22-28-38
14-17-24
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40
NC 20 30 40
Louvered Face Supply520D & VM Performance Data
300.006
.014
.017
.025
45
-
4-6-12
3-5-10
2-3-6
55
-
4-7-13
3-6-10
2-3-7
65
-
4-7-14
3-6-11
2-4-7
80
-
5-8-16
4-6-13
3-4-8
90
-
5-9-17
4-7-14
3-4-8
100
-
5-9-18
4-7-14
3-4-9
115
-
6-9-19
5-7-15
3-5-10
Ac=0.18 ft.2
8 X 4
7 X 5
6 X 6
Ac=0.22 ft.2
10 X 4
8 X 5
7 X 6
Ac=0.26 ft.2
12 X 4
10 X 5
8 X 6
Ac=0.30 ft.2
14 X 4
Ac=0.34 ft.2
16 X 4
12 X 5
10 X 6
Ac=0.39 ft.2
18 X 4
14 X 5
12 X 6
8 X 8
PERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 53
Pric
e
Supply Grilles Models 520D & VM
NC 20
Ac=1.18 ft.2
40 X 5 34 X 6
24 X 8 20 X 10
16 X 12 14 X 14
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
470
-
15-23-40
12-18-32
8-11-20
535
-
16-24-42
13-19-34
8-12-21
540
-
18-26-46
14-21-37
9-13-23
720
-
19-28-48
15-22-38
9-14-24
830
-
20-30-52
16-24-42
10-15-26
980
-
22-33-57
18-26-46
11-16-28
1110
-
23-34-60
18-27-48
12-17-30
.038
.045
.067
590
14
19-28-44
15-22-35
10-14-22
670
14
20-30-47
16-24-38
10-25-23
800
15
22-32-51
18-26-41
11-16-25
900
16
24-35-55
19-28-44
12-17-27
1040
16
26-38-58
21-30-46
13-19-29
1220
17
27-40-62
22-32-50
14-20-31
1390
17
29-42-67
23-34-54
14-21-33
.052
.063
.093
710
19
23-35-48
18-28-38
12-17-24
805
20
24-37-51
19-30-41
12-18-25
960
21
27-39-56
22-31-45
13-20-28
1080
21
29-43-59
23-34-47
14-21-29
1250
22
30-44-63
24-35-50
15-22-32
1470
22
32-48-68
26-38-54
16-24-34
1670
23
35-50-73
28-40-58
17-25-37
.071
.085
.126
825
24
27-38-52
22-30-42
13-19-26
940
24
28-40-56
22-32-45
14-20-28
1120
25
31-43-60
25-34-48
15-22-30
1260
26
32-46-63
26-37-50
16-23-32
1460
26
35-49-68
28-39-54
17-25-34
1720
27
38-54-74
30-43-59
19-27-37
1950
28
40-57-79
32-48-63
20-28-40
.094
.114
.168
945
28
31-40-56
25-32-45
15-20-28
1070
28
35-43-59
26-34-47
16-21-29
1280
29
35-46-64
28-37-51
17-23-32
1440
30
37-49-68
30-39-54
19-24-34
1660
30
40-53-73
32-42-58
20-36-37
1960
31
43-57-80
34-46-64
22-28-40
2220
32
45-61-85
36-49-68
23-30-42
.146
.176
.261
1180
35
36-45-62
29-35-50
18-22-31
1340
35
39-47-65
31-38-52
19-23-33
1600
36
45-51-72
34-41-58
21-26-36
1800
37
45-55-76
36-44-61
22-27-38
2080
37
48-59-82
38-47-66
24-29-41
2450
38
52-64-89
42-51-71
26-32-45
2780
38
55-68-95
44-54-76
28-34-47
.212
.256
.379
1420
40
40-48-67
32-38-54
20-24-34
1610
41
42-52-72
34-42-58
21-26-36
1920
42
46-56-79
37-45-63
23-28-39
2160
42
48-60-84
38-48-67
24-30-42
2500
43
52-64-90
42-51-72
26-32-45
2940
43
57-70-97
46-56-78
28-35-49
3340
44
60-75-104
48-60-83
30-37-52
.287
.347
.514
1650
45
43-52-73
34-42-58
21-26-36
1880
45
45-56-78
36-45-62
23-28-39
2240
46
49-61-85
39-49-68
25-30-43
2520
47
52-65-90
42-52-72
26-32-45
2910
47
56-69-97
45-55-78
28-35-48
3430
48
67-76-106
49-61-85
32-38-53
3890
49
65-81-112
52-65-90
33-40-56
.374
.452
.669
1890
49
45-56-78
36-45-62
23-28-39
2140
50
48-60-83
38-48-66
24-30-42
2560
50
53-65-91
42-52-73
26-32-46
2880
51
56-69-87
45-55-78
28-35-48
3330
51
60-75-104
48-60-83
30-37-52
3920
52
65-81-113
52-65-90
33-42-56
4450
53
70-87-122
56-70-98
35-43-61
.475
.574
.850
2120
53
48-59-83
38-47-66
24-30-41
2410
53
51-63-89
41-50-71
26-32-44
2880
54
56-69-97
45-55-78
28-35-48
3240
54
60-73-103
48-58-82
30-37-51
3740
55
64-79-110
51-63-88
32-40-55
4410
56
70-87-120
56-70-96
35-43-60
5000
56
74-93-128
59-74-102
37-46-64
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50
300.006
.014
.017
.025
335
-
10-17-34
8-14-27
5-8-17
400
-
11-18-36
9-14-29
6-9-18
480
-
13-20-40
10-16-32
6-10-20
540
-
13-21-42
10-17-34
7-11-21
625
-
14-23-45
11-18-36
7-11-23
735
-
15-25-49
12-20-39
7-12-24
835
-
16-26-52
13-21-42
8-13-26
Ac=1.34 ft.2
46 X 5 38 X 6
28 X 8 22 X 10
18 X 12 16 X 14
Ac=1.60 ft.2
44 X 6 32 X 8
26 X 10 22 X 12
18 X 14 16 X 16
Ac=1.80 ft.2
50 X 6 36 X 8
28 X 10 24 X 12
20 X 14 18 X 16
Ac=2.08 ft.2
58 X 6 42 X x8
32 X 10 28 X 12
24 X 14 20 X 16
18 X 18Ac=2.45 ft.2
48 X 8 38 X 10
32 X 12 26 X 14
24 X 16 20 X 18
Ac=2.78 ft.2
56 X 8 14 X 10
36 X 12 30 X 14
26 X 16 24 X 18
22 X 20
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com54
Supply Grilles Models 520D & VM
NC 20
Ac=0.46 ft.2
20 X 4 16 X 5
14 X 6 10 X 8
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
185
-
9-14-25
7-11-20
5-7-12
210
-
10-15-26
8-12-21
5-7-13
240
-
11-16-28
9-13-22
5-8-14
275
-
12-17-30
10-14-24
6-9-15
325
-
13-19-33
10-15-26
6-9-16
360
-
14-20-34
11-16-27
7-10-17
430
-
15-22-38
12-18-30
7-11-19
.038
.045
.067
230
-
12-17-27
10-14-22
6-9-14
260
-
13-19-29
10-15-23
6-9-15
300
-
14-20-31
11-16-25
7-10-16
345
-
15-22-34
12-18-27
7-11-17
405
12
16-23-37
13-18-30
8-12-18
450
13
17-25-39
14-20-31
9-13-19
535
13
18-28-42
14-22-34
9-14-21
.052
.063
.093
275
15
14-22-30
11-18-24
7-11-15
310
16
15-22-32
12-18-26
8-11-16
360
16
16-24-34
13-19-27
8-12-17
415
17
18-26-37
14-21-30
9-13-18
485
18
19-28-40
15-22-32
10-14-20
540
18
21-30-42
17-24-34
10-15-21
640
19
22-33-46
18-26-37
11-17-23
.071
.085
.126
320
20
16-23-32
13-18-26
8-11-16
365
20
18-25-35
14-20-28
9-12-17
420
21
19-27-37
15-22-30
10-13-19
485
22
21-29-40
17-23-32
10-14-20
565
22
23-31-43
18-25-34
11-15-22
630
23
24-33-45
19-26-36
12-16-23
750
24
26-36-49
21-29-39
13-18-25
.094
.114
.168
370
24
19-25-35
15-20-28
10-13-17
415
24
20-26-37
16-21-30
10-13-18
480
25
22-29-40
18-23-32
11-14-20
550
26
24-31-43
19-25-34
12-15-21
650
26
26-33-46
21-26-37
13-17-23
720
27
27-35-48
22-28-38
14-17-24
855
28
29-38-53
23-30-42
14-19-26
.146
.176
.261
460
31
23-27-39
18-22-31
11-14-20
520
31
24-30-41
19-24-33
12-15-21
600
32
26-32-45
21-26-36
13-16-22
690
32
28-34-47
22-27-38
14-17-24
810
33
30-37-51
24-30-41
15-19-26
900
34
32-39-55
26-31-44
16-20-27
1070
34
35-43-59
28-34-47
17-21-29
.212
.256
.379
550
36
25-31-43
20-25-34
12-15-21
625
37
27-33-45
22-26-36
13-16-23
720
37
29-35-48
23-28-38
14-17-24
830
38
30-38-52
24-30-42
15-19-26
970
39
33-41-56
26-33-45
17-20-28
1080
39
35-43-59
28-34-47
17-21-29
1280
40
38-48-64
30-37-51
19-23-32
.287
.347
.514
645
41
27-33-46
22-26-37
14-17-23
730
41
29-35-49
22-28-39
14-18-24
840
42
31-38-52
25-30-42
15-19-26
965
43
33-40-56
26-32-45
16-20-28
1130
43
36-44-60
29-35-48
18-22-30
1260
44
37-46-63
30-37-50
19-23-32
1500
45
41-50-69
33-40-55
20-25-35
.374
.452
.669
735
45
29-35-49
23-28-39
14-18-24
830
45
31-38-52
25-30-42
15-19-26
960
46
33-40-56
26-32-45
16-20-28
1100
47
35-43-60
28-34-48
18-22-30
1300
47
38-46-64
30-37-51
19-23-32
1440
48
40-49-68
32-39-54
20-24-34
1710
49
43-53-74
34-42-59
22-27-37
.475
.574
.850
830
49
31-38-52
25-30-42
15-19-26
935
49
32-40-55
26-32-44
16-20-28
1080
50
35-43-59
28-34-47
17-21-29
1240
50
37-45-63
30-36-50
19-23-31
1460
51
40-49-68
32-39-54
20-25-34
1620
51
42-52-72
34-42-58
21-26-36-
1930
52
46-57-79
37-46-63
23-28-40
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50
300.006
.014
.017
.025
140
-
7-10-22
6-8-18
3-5-11
155
-
7-11-23
6-9-18
3-5-11
180
-
7-12-24
6-10-19
4-6-12
205
-
8-13-26
6-10-21
4-6-13
245
-
8-14-28
6-11-22
4-7-14
270
-
9-15-30
7-12-24
5-8-15
320
-
10-16-32
8-13-26
5-8-16
Ac=0.52 ft.2
24 X 4 18 X 5
16 X 6
Ac=0.60 ft.2
28 X 4 20 X 5
18 X 6 12 X 8
10 X 10
Ac=0.69 ft.2
30 X 4 24 X 5
20 X 6 14 X 8
12 X 10
Ac=0.81 ft.2
36 X 4 28 X 5
22 X 6 16 X 8
14 X 10
Ac=0.90 ft.2
40 X 4 30 X 5
26 X 6 18 X 8
16 X 10 12 X 12
Ac=1.07 ft.2
48 X 4 36 X 5
30 X 6 22 X 8
18 X 10 14 X 12
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 55
Pric
e
Supply Grilles Models 520D & VM
NC 20
Ac=3.11 ft.2
62 X 8 48 X 10
40 X 12 34 X 14
30 X 16 26 X 18
24 X 20
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
1240
-
24-35-63
19-29-50
12-18-31
1440
-
26-38-68
21-30-54
13-19-34
1720
12
28-41-74
22-33-59
14-20-37
1880
13
29-43-78
23-34-62
15-22-39
2230
14
31-47-85
25-38-68
16-23-43
2500
14
33-49-90
26-39-72
17-25-45
.036
.045
.067
1560
18
34-45-71
27-35-57
17-22-35
1800
19
32-47-76
26-38-61
16-23-38
2140
19
35-50-83
28-40-66
17-25-42
2320
20
36-54-87
29-43-70
18-27-43
2790
20
40-59-95
32-47-76
20-30-48
3120
21
42-62-100
34-50-80
21-31-50
.052
.063
.093
1870
23
41-53-78
33-42-62
20-26-39
2170
24
38-56-84
30-45-67
19-28-42
2570
24
42-60-91
34-48-73
21-30-46
2790
25
44-65-95
35-52-76
22-32-48
3350
26
47-72-104
38-58-83
23-36-52
3750
27
50-75-103
40-60-82
25-37-51
.071
.085
.126
2180
28
47-60-84
38-48-67
23-30-42
2530
29
44-65-90
35-52-72
22-32-45
3000
29
49-71-98
39-57-78
24-35-49
3260
30
51-74-103
41-59-82
25-37-52
3910
31
55-81-113
44-65-90
28-41-57
4380
31
58-86-119
46-69-95
29-43-60
.094
.114
.168
2490
32
48-64-90
38-51-72
24-32-45
2890
33
51-69-97
41-55-78
25-35-48
3430
33
56-76-106
45-81-85
28-38-53
3720
34
58-79-110
46-63-88
29-40-55
4460
35
63-87-122
50-70-98
31-44-61
5000
35
67-93-128
54-74-102
34-46-64
.146
.176
.261
3110
39
58-72-100
46-58-80
29-36-50
3610
40
63-78-108
50-62-86
31-39-54
4290
40
69-85-118
55-68-94
34-43-59
4650
41
77-89-123
58-71-98
36-44-61
5580
41
79-97-135
63-78-108
39-49-67
6250
42
84-104-143
67-83-114
42-52-72
.212
.256
.379
3730
44
64-79-110
51-63-88
32-40-55
4330
45
69-88-118
55-69-94
35-43-59
5150
45
76-93-130
61-74-104
38-47-65
5580
46
79-97-135
63-78-108
39-49-67
6700
47
87-107-148
70-86-118
43-53-74
7500
48
92-113-156
74-90-125
46-57-78
.287
.347
.514
4350
49
69-86-118
55-69-94
35-43-59
5050
50
75-93-128
60-74-102
38-46-64
6010
50
82-102-140
66-82-112
41-51-70
6510
51
86-105-146
69-84-117
43-52-73
7810
52
93-116-160
74-93-130
47-53-80
8750
52
96-123-169
78-98-135
49-61-85
.374
.452
.669
4980
53
74-92-128
59-74-102
37-46-64
5780
54
80-99-137
64-79-110
40-50-69
6860
54
88-108-149
70-86-119
44-54-75
7440
55
91-113-156
73-90-125
46-56-78
8930
56
100-125-171
80-100-137
50-62-86
10,000
56
106-132-180
85-105-140
56-66-90
.475
.574
.850
5600
57
79-97-135
63-78-108
40-49-67
6500
57
86-105-146
69-84-117
43-52-73
7720
58
92-115-158
74-92-126
46-57-79
8370
59
96-120-164
77-96-131
48-60-82
10,000
59
106-132-180
85-105-140
53-66-90
11,200
60
112-140-192
90-112-153
56-70-96
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50 60
300.006
.014
.017
.025
935
-
17-27-55
14-22-44
8-14-28
1080
-
18-29-59
14-23-47
9-14-29
1290
-
19-31-64
15-25-51
10-15-32
1400
-
20-33-67
16-26-54
10-16-33
1670
-
22-36-73
18-29-58
11-18-37
1880
-
23-37-78
18-30-62
12-19-39
Ac=3.61 ft.2
72 X 8 58 X 10
48 X 12 36 X 16
30 X 18 28 X 20
24 X 24
Ac=4.29 ft.2
68 X 10 56 X 12
48 X 14 42 X 16
36 X 18 32 X 20
28 X 24
Ac=4.65 ft.2
72 X 10 60 X 12
52 X 14 44 X 16
40 X 18 36 X 20
30 X 24
Ac=5.58 ft.2
72 X 12 60 X 14
54 X 16 48 X 18
42 X 20 36 X 24
Ac=6.25 ft.2
72 X 14 60 X 16
54 X 18 48 X 20
40 X 24 32 X 30
60
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com56
High Capacity Drum Louvers Model HCD1D
FEATURES• Adjustable vanes within a rotatable drum.• Drum is adjustable through 60 degrees.
Positive detent mechanism to fix drum angle setting.
radius of diffusion h 3-5-10 4-6-12 5-7-13 6-9-14 6-10-15 7-11-16 8-12-17 10-13-19 11-14-20 12-15-22
Vertical throw V 9 10 11 12 12 13 14 15 16 17
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 61
Pric
e
DuctSize
6
8
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
ListedSize
Neck Velocity fpmVelocity Pressure in w.g.
.038
78
-
2-3-6
.068
140
-
3-4-8
.059
98
-
2-4-7
.106
175
-
3-5-10
.085
118
-
3-4-8
.153
209
-
4-6-11
.116
137
-
3-5-9
.208
244
-
5-7-12
.152
157
-
4-6-10
.271
279
17
6-8-13
.192
176
18
4-7-10
.343
314
22
6-9-14
.237
196
23
5-7-11
.424
349
27
7-10-15
.341
235
31
6-8-12
.610
419
36
8-11-16
.464
274
38
7-9-13
.831
489
43
10-12-17
.606
314
44
8-10-14
1.085
558
49
11-13-18
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Performance Data – 12 X 12 Face Size
6
8
10
12
14
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160Size
Neck Velocity fpmVelocity Pressure in w.g.
.010
78
-
1-2-4
.018
140
-
2-2-5
.029
218
-
2-3-6
.041
314
-
3-4-8
.057
428
-
3-5-10
.016
98
-
1-2-4
.029
175
-
2-3-6
.045
273
-
3-4-8
.065
393
-
3-5-10
.088
535
-
4-6-12
.023
118
-
2-3-5
.042
209
-
2-4-7
.065
327
-
3-5-9
.093
471
15
4-6-11
.127
641
18
5-7-13
.032
137
-
2-3-6
.057
244
-
3-4-8
.088
382
18
4-6-10
.127
550
21
5-7-12
.173
748
23
6-9-14
.041
157
-
2-4-6
.074
279
19
3-5-9
.115
436
22
4-6-11
.166
628
25
5-8-13
.226
855
27
6-10-15
.053
176
19
3-4-7
.093
314
23
4-6-9
.146
491
26
5-7-12
.210
707
29
6-9-14
.286
962
31
7-11-16
.065
196
22
3-4-7
.115
349
27
4-6-10
.180
545
30
5-8-12
.259
785
33
7-10-15
.353
1069
35
8-12-17
.093
235
29
4-5-8
.166
419
33
5-7-11
.259
654
36
6-9-13
.373
942
39
8-11-16
.509
1283
41
10-13-19
.127
274
34
4-6-9
.226
489
38
6-8-12
.353
763
41
8-10-14
.508
1099
44
9-12-17
.693
1497
46
11-14-20
.166
314
38
5-7-9
.295
558
43
7-9-12
.461
872
46
9-11-15
.664
1256
49
11-13-19
.905
1710
51
12-15-22
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Performance Data – 24 X 24 Face Size
Type 31Lay-in Inverted Tee 1" (25)
Model SPD
24 X 24 22 X 22 21/2 6, 8, 10, 12, 14
12 X 12 101/2 X 101/2 11/8 6, 8
CMCeiling
Opening B
DIMENSIONAL DATA
Square Plaque Diffusers Model SPD/Plaster Frames
Model sPd
CMCeiling
OpeningB Duct Size
24 X 24 22 X 22 2 ½ 6, 8, 10, 12, 14, 15
12 X 12 10 ½ X 10 ½ 1 1/8 6, 8
DiMEnSiOnAL DATA - TYPE 31STOCK SiZES
CMCeiling
OpeningB Duct Size
24 X 24 22 X 22 2 ½ 6, 8, 10, 12, 14
DiMEnSiOnAL DATA - TYPE 17STOCK SiZES
Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25) Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25)
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
sPf stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com62
listedsize
neck Velocity, fpmVelocity Pressure, in w.g.
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
6
total Pressure, in w.g. .038 .059 .085 .116 .152 .192 .237 .341 .464 .606
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 63
Pric
e
Linear Slot Diffuser Model SDSA precisely shaped aerodynamic pattern controller provides a full 180° range of air pattern adjustment from vertical to a tight ceiling hugging horizontal air pattern. The curved, aerodynamic shape of the pattern controller is essential in achieving an exceptionally tight horizontal ceiling pattern.
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
FEATURES • Solid extruded aluminum border and
frame construction.• Modern architectural design; true
flexibility of application.• 180° air pattern adjustment and
complete flow rate control with stable horizontal air pattern.
• no “lefts" or “rights" makes for simple specification and installation.
Non-ducted performance tables can be used to approximate performance data when contractor fabricated plenums are supplied. Plenums must be sized to achieve equal velocity along the slot length. Inlets should be sized to reduce additional contribution of sound or pressure drop.
nC CorreCtion for varioUs diffUser lenGtHs
PerformanCe data
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com64
Linear Slot Diffuser Plenums Model SDBIDrywall / Ceiling Mounted
SDBI
FEATURES PRiCE SDB linear slot plenums are an accessory for SDS linear slot diffusers designed for flexible duct connection in drywall ceiling mount applications. Unless there is access to the ceiling space, the plenum is intended to be installed during the drywall ceiling installation.
Plenum accessories save on-site fabrication and field labor. When room usage changes, plenum accessories simplify rearrangement of air distribution.
• 1/4" (6) internal insulation
Model sdBi 100
nominal lenght
no. of slots
d=nom.inlet
hheight
xWidth
48" nom.
l=48"2 8, 10, 12 10¼ 4¼
DiMEnSiOnAL DATA - in STOCK
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 65
Pric
e
T-Bar Supply Diffusers Model TBDI4
Air Pattern Split Deflection available on36"/900mm, 48"/1200mm" and60"/1500mm units.
CN – Center NotchAllows T-Bar diffuser length to be bi-sected by existingT-Bar (by others).
e.g. Allows 48" (1219) unit to be installed into two 24" (610) ceil-ing modules.
FEATURES PRiCE TBD 4 Series T-Bar diffusers have been designed to provide a tight horizontal air pattern that is suitable for VAV systems. The air pattern is field adjustable toward or away from the diffuser inlet side.
• Pattern controllers are fitted with a tight sealing extruded vinyl blade edge seal.
• 2 slot units feature an extruded aluminum center tee that has been “dropped" below the diffuser face to match the ceiling grid and provide superior performance.
• internal coated fiberglass insulation
AVAiLABLE OPTiOnS - in STOCK• Center notch (Cn) available to bisect diffuser
length (i.e. allows 48"/1200mm unit to be installed into two 24"/600mm ceiling modules).
• Aluminum Plaster Frame (APF).
MATERiAL• Shell - Coated Steel
• Pattern Controller / Center Tee - Extruded Aluminum
• Blade Gasket - Vinyl
FiniSHShell MiLL
Plenum Face / Pattern Controller Black B17
Center Tee - White Powder Coat B12
MODELS
1" (25) Slot Width insulated TBDi4100
11/2" (38) Slot Width insulated TBDi4150
Model length standard inlet With center notch inlet
410024 6, 8
48 6, 8, 10 8, 10
415024 8
48 8, 10, 12 8, 10, 12
Stock Sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Performance Notes:: 1 Units tested in accordance with ASHRAE Standard 70-2006 2 Air flow is in cubic feet per minute, cfm 3 All pressures are in inches of water gauge, W G 4 Throw values are given in feet to terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum) 5 Throw data based on supply air and room air being at isothermal conditions 6 The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser 7 Blanks indicate NC less than 15 8 Shaded area outside recommended operating range
T-Bar Supply Diffuser Model TBDI4
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 67
Pric
e
Perforated Supply Diffusers Model PDF/PDFE
FEATURES
• All steel construction.
• Removable face.
• 4 way adjustable pattern.
• Lay-in models only stocked…for surface mount application use w/SPF plaster frame.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com72
Dampers
VCR 8E
VCR 9 Radial Damper
Dimensional Data —Imperial (inches) / Metric (mm)
NOMINAL SIZES
A B
6"57/8
(150)23/4
(70)
8"77/8
(200)33/4
(95)
1097/8
(250)43/4
(120)
12"117/8
(302)53/4
(146)
14"137/8
(352)63/4
(171)
Dimensional Data —Imperial (inches) / Metric (mm)
Five Segment Blades are rotatedto desired Damper Configuration
Mounting Clip
Ref. Detail ofDiffuser Neck-Inlet
Use Std. Flat Blade Screwdriverto Operate Damper
Top View of Damper
Side View of Damper
A ± 1/32
49/64"
VCR 7 Radial Opposed Blade Damper c/w Duct Ring
VCR 7 gang operated opposed blade damper supplied with duct ring. Easily adjusted with slotted operator. VCR 7 is not recommended for use with flexible duct application.
Dimensional Data — Imperial (inches) / Metric (mm)Nom. Size A B C
Sturdy butterfly type damper provides simple and precise air volume control. Unit can be mounted directly on the diffuser face with a slotted operator. Construced of heavy gauge cold rolled steel. (Not recommended for use with flexible duct.
Duct Size A6 51/2" (140)8 71/2" (191)
10 91/2" (241)
14 131/2" (343)12 111/2" (292)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 73
Pric
e
Spiral Duct Mount Grilles - Model SDG
Type 6*Surface Mount – BevelledNote: Extruded Aluminum Frame
* Stocked with Damper
Type 3PLay-In Inverted Tee Bar 1" (25) Panel
Frame and panel are steel construction.
Type 1Surface Mount
Core Styles Square Necks
Style/Type
Type 1 Type 33
6 X 6
9 X 9
12 X 12
15 X 15
18 X 18
6 X 6
9 X 9
15 X 15
18 X 18
9 X 9
12 X 1212 X 12
6" Ø
8" Ø10" Ø
12" Ø
14" Ø
16" Ø
Louvered Face Diffusers Model SMD
featUres
• Superior performance in exposed duct applications• Vertical front blades• Installation in round duct dia 6" - 48"• Integral gasket seals grille tightly to duct• Built in extractor to allow accurate balancing and flow• Galvanized steel construction• Includes rod operated air scoop for volume control• Mill finish
SIZE CFM RANGE SPIRAL SIZE
10 X 4 60 - 250 8" - OVER
12 X 4 75 - 300 8" - OVER
14 X 4 90 - 360 8" - OVER
16 X 4 100 - 400 8" - OVER
18 X 4 110 - 460 8" - OVER
24 X 4 150 - 620 8" - OVER
10 X 6 100 - 400 14" - OVER
12 X 6 120 - 450 14" - OVER
14 X 6 140 - 550 14" - OVER
16 X 6 150 - 600 14" - OVER
18 X 6 180 - 720 14" - OVER
24 X 6 270 - 1050 14" - OVER
10 X 8 140 - 550 22" - OVER
16 X 8 240 - 950 22" - OVER
24 X 8 350 - 1400 22" - OVER
sdG models/sizes - in stoCk
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com74
Louvered Face Diffusers Model SMD
15" X 15"
3000.036
4000.065
5000.099
6000.144
7000.196
8000.256
9000.324Size
Neck VelocityTotal Pressure
468
10
117
10-15-21
156
13-17-25
195
16-20-28
234
17-21-30
273
19-23-33
313
20-25-35
352
21-26-37
A B A B A B A B A B A B A B
625
19
781
26
938
32
1094
35
1250
40
1406
44
Total CFM
NC
CFM/Side
Throw,ft.
PERFORMANCE DATA
Duct
Area
1.56
ft2
18" X 18"
Duct
Area
2.25
ft2
6 X 6 0.73 TP Listed NC
9 X 9 0.87 TP Listed NC +2
12 X 12 0.93 TP Listed NC +4
15 X 15 1.27 TP Listed NC +4
18 X 18 1.47 TP Listed NC +6
DuctSize (-) SP
4A
675
12
169
12-17-24
225
16-19-27
281
18-22-31
338
19-24-34
394
21-26-36
450
22-27-39
506
24-29-41
A B A B A B A B A B A B A B
900
21
1125
28
1350
34
1575
38
1800
42
2025
46
Total CFM
NC
CFM/Side
Throw,ft.4A
12" X 12"300
-
75
8-12-19
100
11-15-22
125
13-17-24
150
15-19-27
175
17-20-29
200
18-22-31
225
19-23-33
A B A B A B A B A B A B A B
400
17
500
24
600
30
700
34
800
38
900
42
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
1.00
ft2 4A
9" X 9"169
-
42
6-9-16
56
8-12-18
70
10-15-21
85
12-16-23
99
14-17-24
113
15-18-26
127
16-20-28
A B A B A B A B A B A B A B
225
14
282
21
338
27
394
31
450
35
507
39
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
0.56
ft2 4A
6" X 6"75
-
19
4-6-12
25 31
5-8-15
38
7-10-16
44
8-12-18
50
9-14-19
56
11-15-21 12-16-22
A B A B A B A B A B A B A B
100
10
125
17
150
23
175
27
200
31
225
36
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
0.25
ft2 4A
SMD / RETURN FACTORS
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 75
Pric
e
Egg Crate Grilles Model 80/Plaster Frames
featUres
• 1/2" x 1/2" x 1/2" aluminum grid core • Extruded aluminum borders and frames • High capacity return or exhaust outlet
and pressure drops • Ideal for pressurized ceiling return or size
• High capacity return or exhaust outlet and pressuredrops.
• Ideal for pressurized ceiling return or size restrictedexhaust applications.
• B12 off-white finish.
10 X 10
22 X 10
22 X 22
46 X 22
24 X 24
24 X 48
SIZES
T-Bar Lay-in – TB Border
Molded of light stablepolystyrene. Light weight,durable and rigid; will notwarp or discolor. An Egg-Crate cell design providesfree circulation of air.
Model #CCPTB (Egg-Crate) (Plastic)Off-set provides continuous effect.
233⁄4 X 233⁄4
473⁄4 X 233⁄4
24 X 24
48 X 24
Actual Nominal
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
sUrfaCe moUnt stoCk sizes
12 X 6
SPF STOCK SiZES
12 X 1224 X 1224 X 2448 X 24
lay-in stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com76
Egg-Crate Grilles Model 80/Plaster FramesPERFORMANCE DATA
75
-
90
-
110
-
130
-
150
-
170
-
195
-
230
15
260
15
300
16
345
16
405
17
450
18
535
18
590
19
670
19
800
20
900
21
1040
21
1225
22
1390
22
1555
23
1805
24
2145
24
2325
25
2790
25
3125
26
10 X 10
12 X 10
14 X 10
16 X 10
12 X 12
14 X 12
14 X 14
16 X 14
18 X 14
16 X 16
24 X 12
20 X 14
30 X 12
24 X 14
24 X 16
20 X 18
22 X 20
30 X 16
26 X 18
30 X 18
24 X 24
6 X 6
7 X 6
8 X 6
10 X 6
12 X 6
8 X 8
14 X 6
10 X 8
16 X 6
18 X 6
12 X 8
20 X 6
14 X 8
22 X 6
16 X 8
26 X 6
18 X 8
30 X 6
18 X 10
20 X 10
16 X 12
36 X 6
18 X 12
24 X 10
22 X 12
36 X 8
30 X 10
40 X 8
36 X 10
32 X 12
26 X 14
26 X 16
24 X 18
40 X 12
36 X 14
48 X 12
36 X 16
32 X 20
28 X 24
36 X 20
30 X 24
48 X 18
36 X 24
48 X 20
30 X 30
NC 20
Core AreaSquare Feet
Core Velocity Velocity Pressure
Negative SPNominal Size
0.15
0.18
0.22
0.26
0.30
0.34
0.39
0.46
0.52
0.60
0.69
0.81
0.90
1.07
1.18
1.34
1.60
1.80
2.08
2.45
2.78
3.11
3.61
4.29
4.65
5.58
6.25
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
30 40
NC 20 30 40 50 60
Egg-Crate Face 80Performace Data
300.006.014
45
-
54
-
66
-
78
-
90
-
102
-
117
-
138
-
156
-
180
-
207
-
243
-
270
-
321
-
354
-
402
-
480
-
540
-
624
-
735
-
834
-
933
-
1083
-
1287
-
1395
-
1674
-
1875
-
400.010.024
60
-
72
-
88
-
104
-
120
-
136
-
156
-
184
-
208
-
240
-
276
-
324
-
360
-
428
-
472
-
536
-
640
-
720
-
832
-
980
15
1112
15
1244
16
1444
17
1716
17
1860
18
2232
18
2500
19
500.016.038
600.022.052
90
16
108
17
132
17
156
18
180
19
204
19
234
20
276
21
312
21
360
22
414
22
486
23
540
24
642
24
708
25
804
25
960
26
1080
27
1248
27
1470
28
1668
28
1866
29
2166
30
2574
30
2790
31
3348
31
3750
32
700.031.074
105
21
126
22
154
22
182
23
210
24
238
24
273
25
322
26
364
26
420
27
483
27
567
28
630
29
749
29
826
30
938
30
1120
31
1260
32
1456
32
1715
33
1946
33
2177
34
2527
35
3003
35
3255
36
3906
36
4375
37
800.040.095
120
26
144
27
176
27
208
28
240
29
272
29
312
30
368
31
416
31
480
32
552
32
648
33
720
34
856
34
944
35
1072
35
1280
36
1440
37
1664
37
1960
38
2224
38
2488
39
2888
40
3432
40
3720
41
4464
41
5000
42
1000.062.147
150
33
180
34
220
34
260
35
300
36
340
36
390
37
460
38
520
38
600
39
690
39
810
40
900
41
1070
41
1180
42
1340
42
1600
43
1800
44
2080
44
2450
45
2780
45
3110
46
3610
47
4290
47
4650
48
5580
48
6250
49
1200.090.213
180
39
216
40
264
40
312
41
360
42
408
42
468
43
552
44
624
44
720
45
828
45
972
46
1080
47
1284
47
1416
48
1608
48
1920
49
2160
50
2496
50
2940
51
3336
51
3732
52
4332
53
5148
53
5580
54
6696
54
7500
55
1400.122.289
210
44
252
45
308
45
364
46
420
47
476
47
546
48
644
49
728
49
840
50
966
50
1134
51
1260
52
1498
52
1652
53
1876
53
2240
54
2520
55
2912
55
3430
56
3892
56
4354
57
5054
58
6006
58
6510
59
7812
59
8750
60
1500.140.332
225
46
270
47
330
47
390
48
450
49
510
49
585
50
690
51
780
51
900
52
1035
52
1215
53
1350
54
1605
54
1770
55
2010
55
2400
56
2700
57
3120
57
3675
58
4170
58
4665
59
5410
60
6435
60
6975
61
8370
61
9375
62
7 X 7
6 X 5
8 X 4
7 X 5
10 X 4
8 X 5
12 X 4
10 X 5
14 X 4
16 X 4
12 X 5
18 X 4
14 X 5
20 X 4
16 X 5
24 X 4
18 X 5
28 X 4
20 X 5
30 X 4
24 X 5
36 X 4
28 X 5
40 X 4
30 X 5
48 X 4
36 X 5
34 X 6
24 X 8
60 X 4
48 X 5
72 X 4
30 X 8
60 X 5
48 X 6
72 X 5
60 X 6
72 X 6
48 X 8
36 X 12
30 X 14
60 X 8
48 X 10
72 X 8
60 X 10
48 X 14
36 X 18
72 X 10
48 X 16
72 X 12
60 X 14
72 X 14
60 X 16
18 X 16
20 X 16
18 X 18
24 X 20
60
50
PerformaceNotes:1.) Tested per ADC Equipment code 1062: GDR-84. ASHRAE Standard 70-72. 2.) All pressures are in inches of water. 3.) Neg. SP is negative static pressure. 4.) NC valuesare based on room absorption of 10 dB.re 10
12watts. 5.) Grille tested with damper. Corrections for grille without damper: — Multiply negative static pressure by 0.92. — Subtract 4 dB from listed NC.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 77
Pric
e
Round Neck Adaptors Model SR3
1.65
3.5
1.4
3.5
1.65
3.5
1.9
1.25
3.5
2.0
1.45
3.7
2.25
1.6
1.2
3.5
2.35
1.65
1.33
7
17
4
17
7
17
9
3
17
10
5
17
11
6
3
17
12
7
4
6 X 68 X 88 X 88 X 89 X 99 X 99 X 9
10 X 1010 X 1012 X 1212 X 1212 X 1212 X 1215 X 1515 X 1518 X 1818 X 18
* 20 X 10 ** 22 X 22 *
Neck Size
66786788
1089
10121214161800
"D" Duct Size
6 X 6
9 X 9
9 X 9
12 X 12
12 X 12
15 X 15
15 X 15
15 X 15
18 X 18
18 X 18
18 X 18
21 X 21
21 X 21
21 X 21
21 X 21
24 X 24
24 X 24
24 X 24
24 X 24
5
6
8
8
10
10
12
14
12
14
16
14
16
18
20
16
18
20
22
1.10
1.15
1.10
1.15
1.10
1.15
1.10
1.05
1.15
1.10
1.10
1.15
1.10
1.10
1.05
1.15
1.10
1.10
1.05
1.10
1.15
1.10
1.15
1.10
1.15
1.10
1.05
1.15
1.10
1.10
1.15
1.10
1.10
1.05
1.15
1.10
1.10
1.05
1.15
1.20
1.10
1.20
1.15
1.20
1.15
1.10
1.20
1.15
1.10
1.20
1.15
1.10
1.10
1.20
1.15
1.15
1.10
AMD/SMDSize
RoundNeck
TPCorrection(Multiply)
NCCorrection
(Add) VT 150 VT 100 VT 50
PERFORMANCE CORRECTIONFACTORS FOR SR ADAPTORS
Throw Correction (Multiply)
* 6” through 18” starting collars available
neck size “d" duct size
6 X 6 6
8 X 8 6, 7, 8
9 X 9 6, 7 8
10 X 10 6, 8, 10
12 X 12 6, 8, 9, 10, 12
15 X 15 12, 14
18 X 18 16, 18
22 X 10 0, 6, 8, 10
22 X 22 0, 6, 8, 10, 12, 14, 16, 18PerformanCe CorreCtionfaCtors for sr adaPtors
stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com78
Single Duct – Controller Type SPV, SDV, SEV Series
SPV
SDV, SEV
sPV (Pneumatic)• Fiber free foam insulation with self sealing edges
which meets requirements of UL181 • 22 ga zinc coated steel housing Mechanically
sealed and gasketed, leak resistant construction • Rectangular discharge opening with slip and drive
cleat duct connection • Control assembly will be supplied as illustrated on
right hand size unless specified otherwise • Gauge taps are standard • Pneumatic actuator supplied & mounted by Price • Clean, Dry, 20 PSI (138 KPa) control air required
sdV (ddc by Others)• Fiber free foam insulation with self sealing edges
which meets requirements of UL181 • 22 ga zinc coated steel housing Mechanicallysealed
and gasketed, leak resistant construction • Rectangular discharge opening with slip and drive-
cleat duct connection • Chicago building code controls enclosure • Actuator & controls by others
seV (Analog electronic controls) – Include SDV features and the following• Pressure independent• All control components are factory wired, calibrated
and pre-tested to ensure a fully functional unit • An electronic thermostat is furnished with each unit • Airflow adjustments can be made directly at the
thermostat
*These size are available from warehouse stock in either pressure independent pneumatic controls or set up to receive DDC controls in field Price includes (controlenclosure, 120/24 VAC transformer and disconnect)
CP 101Electronic or Digital Controls
Unit L/S CFM
Size Range Range
4 0-106 0-225
5 0-165 0-350
* 6 0-212 0-450
7 0-307 0-600
* 8 0-378 0-800
9 0-496 0-1050
* 10 0-637 0-1350
* 12 0-991 0-2100
* 14 0-1510 0-3200
16 0-1888 0-4000
B C A L
305 203 102 562
305 203 127 562
305 203 152 511
305 254 178 511
305 254 203 511
356 318 229 511
356 318 254 511
406 381 305 511
508 445 356 600
610 457 406 600
12 8 4 221/8
12 8 5 221/8
12 8 6 201/8
12 10 7 201/8
12 10 8 201/8
14 121/2 9 201/8
14 121/2 10 201/8
16 15 12 201/8
20 171/2 14 231/8
24 18 16 231/8
B C A L
Outlet Inlet Length Outlet Inlet Length
S.I. Units mm Imperial Units Inches
Unit Size L/s Min. L/s Max. cfm Min. cfm Max.
4 24 106 50 225
5 30 165 63 350
6 31 212 66 450
7 47 307 99 650
8 62 378 132 800
9 79 496 167 1050
10 104 637 221 1350
12 143 991 304 2100
14 207 1510 439 3200
16 268 1888 650 3600
Unit Size L/s Min. L/s Max. cfm Min. cfm Max.
4 24 106 50 225
5 30 165 63 350
6 31 212 66 450
7 47 307 99 650
8 62 378 132 800
9 79 496 167 1050
10 104 637 221 1350
12 143 991 304 2100
14 207 1510 439 3200
16 268 1888 650 3600
AIR VOLUME RANGES
*
*
****
* in-stock
air volUme ranGes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 79
Pric
e
Single Duct – Controller Type SPV, SDV, SEV Series
Discharge NCBasic AssemblyΔPs Across Unit0.5" 1.5" 3"
W.G. W.G. W.G.125Pa 375Pa 750Pa
Radiated NCBasic AssemblyΔPs Across Unit0.5" 1.5" 3"W.G. W.G. W.G.
125Pa 375Pa 750Pa
Discharge NC c/w36" AttenuatorΔPs Across Unit0.5" 1.5" 3"W.G. W.G. W.G.
125Pa 375Pa 750Pa
Single Duct – Control Type SPV, SDV, SEV SeriesMinimum ΔPs Across Assembly
Performance Notes:1. NC's are derived from sound power levels, which are obtained in accordance with ARI Standard 880-98.2. Airflow is given in Litres/second, L/s and Cubic Feet/minute, CFM.3. Blank spaces indicate NC's less than 15.4. Minimum ΔPs across the unit is the lowest inlet to discharge pressure differential at which controls are
pressure independent.5. ΔPs is the difference in static pressure form inlet to discharge of the unit.6. Pressure is given in Pascals, Pa and Inches of Water Gauge, in.w.g.7. NC values are calculated based on procedures outlined in Appendix E, ARI Standard 885-98, "A Procedure
for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets." The chartto the right shows the attenuation deductions that have been used for NC calculations:
Correction Factors – 1, 2 and 4 Row Hot Water Coils
Performance Notes:
1. Tabled values are in MBH (thousands of BTU per hour)
2. Tables are based on a temperature difference of 125°F (180°F entering water temperature and 55°F enteringair temperature). For other temperature differences, multiply MBH values by factors as listed above.
3. Minimum air and water flow values are based on ASHRAE recommendations for coil selection. Forselections below these tabulated air or water flow values, please consult your local Price representative.
4. Do not select coils for a leaving air temperature above 120°F.
5. HD(head) loss is in feet of water.
6. ∆Ps, is the pressure drop in inches of water across the coil.
7. For airflow static pressure loss data, see selection guide on page F-12.
8. Air temperature rise=ATR
ATR (F°) = 927 x MBH/CFM
9. Water temperature drop=WTD
WTD (F°) = 2.04 x MBH/GPM
10. Values in tables are listed for 0 feet of altitude and no glycol in the system.
11. For information outside the ranges used in the table, consult Quick Select Software or your Pricerepresentative for accurate coil information.
12. Connections:Single circuit are 1/2" OD male soder.Multi circuit are 7/8" OD male soder.
1 & 2 roW Hot Water Coil data – stoCk sizes
Performance notes:
1 Tabled values are in MBH (thousands of BTU per hour)
2 Tables are based on a temperature difference of 125°F (180°F entering water temperature and 55°F entering air temperature) For other temperature differ-ences, multiply MBH values by factors as listed above
3 Minimum air and water flow values are based on ASHRAE recommenda-tions for coil selection For selections below these tabulated air or water flow values, please consult your local Price representative
4 Do not select coils for a leaving air temperature above 120°F
5 HD(head) loss is in feet of water
6 ÆPs, is the pressure drop in inches of water across the coil
7 Air temperature rise=ATR
ATR (F°) = 927 x MBH/CFM
8 Water temperature drop=WTD
WTD (F°) = 2 04 x MBH/GPM
9 Values in tables are listed for 0 feet of altitude and no glycol in the system
10 For information outside the ranges used in the table, consult your Brucker representative for accurate coil information
11 Connections: Single circuit are 1/2" OD male soder Multi circuit are 7/8" OD male soder
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com82
Control Sequence Model SPV/SEV
sequence of operation - Pressure independent, variable volume, normally open, direct acting cooing application, with optional reheat.
An increase in space temperature increases the thermostat output pressure Wen the thermostat output increases to 13 psi or more, the VAV box damper is maintained at he preselected maximum flow setting
A decrease in space temperature decreases the thermostat output pressure Whent he thermostat output decreases to 8 psi or less, the VAV box damper is maintained at the preselected minimum flow setting
At thermostat output pressures between 8 & 13 psi the VAV damper modulates between minumum & maximum flow
At thermostat output pressures below 8 psi the minumum flow setting is main-tained, and the thermostat may control optional reheat coils
Airflow is held constant at any given thermostat output pressure regardless of changes in inlet duct static pressure
normally Open damper:
On failure of the main air supply the damper will fail to the open position
sequence of operation - Pressure independent, variable volume, cooling only.
On an increase in space temperature the space thermostat regulates control-ler/actuator to open the VAV damper and increase the flow of cool air On an increase in space temperature greater than the cooling proportional band, the airflow is maintained at a preselected maximum flow setting
On a decrease in space temperature the thermostat will regulate the controller/actuator to close the VAV damper and reduce the flow of cool air If the space temperature decreased to less than the cooling proportional band, the airflow is maintained at the preselected minimum flow setting
Airflow is held constant regardless of changes in duct static pressure
SPV Control Sequence
SEV Control Sequence
\1 \ /
control sequencePneuMAtic cOntrOls number 1008
AIR FLOW
FLOW SENSOR
NORMALLY OPEN 5-10 PSIDAMPER PNEUMATIC
ACTUATOR
GAUGE TAPS
TYPE CP101CONTROLLER8-13 PSI RESET
B
M
Go
I I I I
TO OPTIONAL REHEAT COIL I LN O 3-8 PSI HEATING VALVE,I
I T OR PE SWITCH
I I SEE WIRING DIAGRAM I I
I DIRECT ACTING MAIN AIR 1 OR2 PIPE 20 PSI THERMOSTAT
Sequence of Operation -- Pressure independent, variable1) TOTAL AIR 0 017 SCFM volume, normally open, direct acting cooling application,
optional reheat An increase in space temperature increases the thermostat outputLEGENDpressure When the thermostat output increases to 13 psi or theVAV box damper is maintained at the preselected maxirnum flow
FACTORY PNEUMATIC TUBING
------- FIELD PNEUMATIC TUBINGsetting A decrease in space temperature decreases the thermostat output
CONTROL GRAPH pressure When the thern10stat output decreases to 8 psi or less, theOPEN VAV box damper is maintained at the preselected n1inimun1 flowMax Cooling setting
At thermostat output pressures between 8 & 13 psi the VAV damper> modulates between minimum & maximum flow
At thermostat output pressures below 8 psi the minimum flow settingMin Cooling
n1aintained, and the thermostat may control optional reheat coils CLOSE Airflow is held constant at any given thermostat output pressure
Set PointCool Room Condition Warm regardless of changes in inlet duct static pressure
Normally Open Damper:C)n failure of the will fail toposn:i
SPV8 I RPV8 I LPV8
Kreuter CP101
Clg , Reheat Optional
Variable Volume
Pressure Independent
D A T'Stat, N O Damper
231691
03/07/10
SHEET 1 OF 1 REV 0 Printed in Canada
\1 \ /
control sequencePneuMAtic cOntrOls number 1008
AIR FLOW
FLOW SENSOR
NORMALLY OPEN 5-10 PSIDAMPER PNEUMATIC
ACTUATOR
GAUGE TAPS
TYPE CP101CONTROLLER8-13 PSI RESET
B
M
Go
I I I I
TO OPTIONAL REHEAT COIL I LN O 3-8 PSI HEATING VALVE,I
I T OR PE SWITCH
I I SEE WIRING DIAGRAM I I
I DIRECT ACTING MAIN AIR 1 OR2 PIPE 20 PSI THERMOSTAT
Sequence of Operation -- Pressure independent, variable1) TOTAL AIR 0 017 SCFM volume, normally open, direct acting cooling application,
optional reheat An increase in space temperature increases the thermostat outputLEGENDpressure When the thermostat output increases to 13 psi or theVAV box damper is maintained at the preselected maxirnum flow
FACTORY PNEUMATIC TUBING
------- FIELD PNEUMATIC TUBINGsetting A decrease in space temperature decreases the thermostat output
CONTROL GRAPH pressure When the thern10stat output decreases to 8 psi or less, theOPEN VAV box damper is maintained at the preselected n1inimun1 flowMax Cooling setting
At thermostat output pressures between 8 & 13 psi the VAV damper> modulates between minimum & maximum flow
At thermostat output pressures below 8 psi the minimum flow settingMin Cooling
n1aintained, and the thermostat may control optional reheat coils CLOSE Airflow is held constant at any given thermostat output pressure
Set PointCool Room Condition Warm regardless of changes in inlet duct static pressure
Normally Open Damper:C)n failure of the will fail toposn:i
SPV8 I RPV8 I LPV8
Kreuter CP101
Clg , Reheat Optional
Variable Volume
Pressure Independent
D A T'Stat, N O Damper
231691
03/07/10
SHEET 1 OF 1 REV 0 Printed in Canada
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 83
Pric
e
VAV Cooling and VAV Heating VPD-HC Varitherm® diffusers feature an architecturally appealing solid plaque design and high performance control linkage The plaque can be opened to allow easy access to temperature set point dials, and minimum airflow adjustment
Thermal actuators sense room air and adjust airflow into the space to satisfy the room load, requiring no wires for simple installation and maintenance
standard construction Features
• Steel backpan, faceplate and linkage for strength and durability
• Thermal elements for consistent, repeatable performance
• Hinged faceplate, with powerful magnetic closure ensures simple yet strong closure, that also allows for quick access to adjustment features
• Specially engineered damper stack for reduced linkage binding and superior performance over the entire operating range
standard linkage and control Features
• Individual heating and cooling set points
• Minimum airflow adjustment
• Balancing mode for easy setup
• Automatic heating /cooling changeover
• Engineered damper lift track for a more predictable linear perfor-mance and for isolating the force of the damper on the linkage for freer, smoother operation – improving the response of the diffuser to fluctuating room loads
Finish
White Powder Coat B12
VAV Diffuser Varitherm® Model VPD-HC
Ceiling Module Nominal Imperial Metric Duct
24 x 24 600 x 600 6, 8,10,12 (610x610) (152, 203, 254, 305)
Ceiling Module
Nom. Duct
Nom. Duct - 1/4" (3)
2 1/2"(64)
Diffuser Plaque
3 15/16"(101)
dimensional data - stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com84
VAV Diffuser Varitherm® Model VPD-HC
Performance Notes:1. Performance data is presented for Varitherm® diffuser
at several modulated damper positions with constant duct static pressures of 0.10, 0.20, 0.30, and 0.40 inches w.g.
Performance Notes:1. Performance data is presented for the Varitherm®
diffuser with the damper in the full open (maximum fl ow) position.
2. Tested in accordance with ASHRAE Standard 70-1991 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
3. Air fl ow is in cubic feet per minute, CFM.4. All pressures are in inches of water.5. Throw values are given in feet to terminal velocities of
150-100-50 fpm.6. Throw data is based on supply air and room air at
isothermal conditions.
2. Tested in accordance with ASHRAE Standard 70-1991 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
3. Air fl ow is in cubic feet per minute, CFM.4. Throw values are given in feet to terminal velocities of
150-100-50 fpm.
5. Throw data is based on supply air and room air at isothermal conditions.
6. The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser.
7. Blanks “—” indicate an NC level below 15.
7. The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 87
ACCE
SS D
OORS
Access Doors
Access Doors – Hinged or Double Catch Lock 88
stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com88
Access Doors –Hinged or Double Catch Lock
COnSTRUCTiOn SPECiFiCATiOnS• frame: 22 ga. Galv steel• door: 24 ga. Galv steel• insulation: 1" thick fiberglass• frame sizes shown are nominal actual opening sizes
are 1-1/4" smaller
roUnd dUCt aCCess doors model dsa-Ga
6 X 6 12 X12 18 X 18
8 X 8 14 X 14 20 X 20
10 X 10 16 X 16 24 X 24
SiZES AVAiLABLE
SPECiFiCATiOnS• formed 20 guage metal plates• Polfoam insulation• steel bolt• steel compression springs• Polypropylene knobs with metal inserts• Closed cell neoprene gasket
nOTES• available in the following materials:
- Galvanized - stainless steel - aluminum Contact factory for availbility of other materials.
• inner plate is 2" smaller in diameter than outer plate.• Bolt length is increased for easy installation.• self adhesive template included for accurate cut-out• reference chart for sizes
model Cad
model Had
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 89
FLEX
IBLE
TEC
H., T
RIAN
GLE
MFG
.
FLEXIBLE TECHNOLOGIES, TRIANGLE MFG.
Flexible Tubing 90
Locking Ties 90
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
KM X X X X X X X X Insulated – Low to High Pressure
SLP-10 X X X X X X X X X X Non Insulated – Low to High Pressure
STL X X X Non Insulated – Low to Medium Pressure
Model Max. diameter length
SLT10H 10 35
STLT14H 14 46
KM S-LP-10STL
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 91
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Q’Mark, Leading Edge & ThermostatsUnit Heaters Type MUH 92
Architectural Heavy-Duty Wall Heaters — Type AWH-4000 94
Commercial Wall Heaters – Fan-Forced — Type CWH-1000 95
Commercial Wall Heaters – Fan-Forced — Type CWH-3000 96
Ceiling Mounted Heaters – Fan-Forced — Type QCH 97
Electric Baseboard Heaters — Type 2500 97
Commercial Downflow Ceiling Mounted Heaters — Type CDF 98
Heat Recovery Ceiling Fans (Leading Edge) 99
Thermostats 101
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com92
APPLiCATiOnSUnit mounts either horizontally or vertically. totally versatile. for fac-tories, warehouses, garages, stores, shipping rooms, power stations, aircraft hangers. Can be used for primary, supplementary, spot, or dual-system heating.
FEATURES• Wide range of optional control kits are field installable, increasing the mUH
adaptability to the specification market.
• forced air unit heater with 10 power ratings; from 3 kW to 50 kW heating output; 208, 240, 277 and 480v, 10,230 to 170,500 BtU/hr.
• 32 compatible models (no need to try to assemble a heating system from 70 or 80 models!)
• Heavy gauge die-formed steel housing. two-toned, smartly styled.
• advanced pull-through air flow design draws air across heating element for more even air distribution and cooler element operation.
• specially designed venturi outlet to meet that added throw as required in vertical position.
• Branch circuit fusing (when required).
• Completely enclosed fan motor.
• 1- or 3-phase wiring on 5 through 10 kW 208/240v and 15 kW 208v units (field interchangeable).
• aluminum-finned, copper clad steel sheath heating element has longer useful life, because of cooler sheath temperature and faster heat dissipa-tion.
• 24v control transformer standard on most models, providing a safer and more accurate means of temperature control. 3 kW and 5 kW, 208-277v, have line voltage controls as standard (24v control available on made-to-order basis).
• automatic reset linear thermal cut-out, capillary type, provides protection over entire length of element areas (manual reset protection available on made-to-order basis).
• 2-speed fan selector switch (25 to 50 kW models).
• fan delay feature eliminates cold drafts. element heats up before fan cuts in, then fan continues to distribute heat after element shuts off.
• ruggedly built, yet lighter weight for easier installation. no piping flues, valves, or traps.
• individually adjustable discharge louvers to control air flow.
• Choice of optional diffusers for variety of air patterns, maximizing heat concentration and coverage in the vertical position.
• meets all Ul, neC, and osHa requirements.
Unit Heaters Type MUH
MOUnTinG LiMiTATiOnSUnit heaters should not be used in potentially explosive atmo-spheres. the finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swim-ming pools, chemical storage bins, etc. do not install unit heaters above recommended maximum mounting height. obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7’ above the floor to prevent accidental contact with the heating element or fan blade which could cause injury.
cAtAlOG nuMBer used On
MMB10 MUH03, 05, 07 & 10
MMB20 MUH15 & 20
MMB30 MUH25 & 30
MMB50 MUH40 & 50
diMensiOn 3 - 20kw 25 - 50kw
A 7¼" 97/16"
B 9½" 143/8"
c 7¼" 121/8"
d 1115/16" 21/16"
e 2¼" 3"
l 20½" 2815/16"
M 915/16" 1415/16"
n 3¼" 4½"
BRACKET SIZE
UNIVERSAL WALL & CEILING BRACKET cAtAlOG nuMBer
heiGht Width dePth
Muh03 & 05 16" 14" 7½"
Muh07 & 10 21¾" 19" 7½"
Muh15 & 20 21¾" 19" 12¾"
Muh25 & 30 30" 265/8" 11¾"
Muh40 & 50 30" 265/8" 171/8"
DIMENSIONS
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 93
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
CATALOGNUMBER
ELECTRICAL DATACONTROLVOLT (1)
2 STAGE ELEMENT CONTROL
AIR DELIVERY DATA FAN MOTOR DATA MOUNTING HEIGHTHORIZ.THROW
NOTES:1 All standard units are supplied with a low voltage control transformer and contactor (24V) except MUH03 & 05, 208, 240 & 277 volt models Low voltage control on these units is available on made to order All units are also available on special order for 120 volt control; internal with transformer or external without transformer 2 On dual voltage units CFM, FPM, & RPM ratings are listed at higher voltage operation in Full Line Catalog 3 On dual phase units maximum amp draw is listed for respective voltage in Full Line Catalog 4 25 thru 50 KW models having two-speed motors and dual CFM ratings are listed in Full Line Catalog 5A Standard5B Optional - made to order - amp load unbalanced on 3 Phase 5C Optional - made to order - amp load balanced on 3 Phase * Must use 2-stage Thermostat on 3Ø operation
CATALOG NO. DESCRIPTION ELECTRICAL RATING USE WITH
MT1Single Pole Internal Thermostat-Temp.Range: 40F - 85F
25A @ 120, 240VAC Res.22A @ 277VAC Res.
All MUH Series Heaters (except MUH0521 3Ø, which use MT2).
APPLiCATiOnSQmark’s high-capacity, heavy-duty fan-forced wall heaters are designed for use almost anywhere in commercial or industrial areas requiring high capacity and quick recovery. they perform exceptionally well in such applications as motels, entryways, stores, public rest rooms, warehouses and other large, hard to heat areas.
FEATURES• 1500, 2000, 3000, 4000, and 4800 watts; 208, 240, 277 volts; 60 hz.
• steel finned metal sheath electric heating elements with low sheath temperatures provide uniform heat and long service life.
• Closely spaced grille bars discourage insertion of foreign objects and direct air downward to effectively distribute heat…keeping floors warm and dry.
• integral thermostat for quick installation… separate thermostat not necessary. (range: 40° - 90°f.) aWH series has tamper resistant thermostat adjustable with a narrow blade screwdriver through the bar grille.
• thermal overheat protector disconnects power in case of over heating due to accidental blockage.
• Built-in double-pole power disconnect switch for added safety dur-ing maintenance.
• Built-in fan delay switch energizes fan motor only after elements are heated…prevents discharge of unheated air. When heat shuts off, de-energizes fan motor after residual heat has been dissipated.
• Can be wired with standard 60°C wire.
• Permanently lubricated totally enclosed fan motor provides long life and low maintenance; gently distributes warmth throughout room area. 100 Cfm.
• Contemporary steel bar grille with durable polyester powder coat finish and satin finished aluminum frame…retains attractive appear-ance through years of use.*
• optional accessory power control relays (24 or 120v holding coil) or pneumatic electric (P/e) switch.
• recess or surface mount in standard 2" x 4" stud walls.
* Northern White color is optional. (Add NW suffix to cat. #).
MOUnTinG LiMiTATiOnS1. for wall mounting - do not install back box closer
than 8 inches from floor or adjacent wall.2. do not install heater behind towel rack, behind
door, in floor, in closet, in ceiling or where air flow may be obstructed.
all controls are concealed behind the front cover making them essentially tamper proof. they will accommodate pneumatic/electric or low-voltage controls commonly used with computerized energy management systems.
*Heaters shipped at higher wattage. Units can be converted to half-wattage in field.
CATALOG NUMBER DESCRIPTION
AWHSM Surface Mounting Frame15-3/8" W x 19-3/16" H x 3-3/4" D
AWHS1 1" Semi-Recess Mounting Frame15-3/8" W x 19-3/16" H x 1" D
AWHS2 2" Semi-Recess Mounting Frame15-3/8" W x 19-3/16" H x 2" D
AWHR2 24V H.C. Time Delay Relay
aCCessories & Controls (oPtional)
seleCtion CHart - stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 95
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Commercial Wall Heaters – Fan-ForcedType CWH-1000
APPLiCATiOnSfast heat response, compact design and versatility make the CWH1000 series heaters ideal for dens, basements, con-verted attics and breeze ways, garages, bathrooms, small offices, workshops and similar areas. also, adaptable to mul-tiple installations in somewhat larger or odd shaped rooms.
FEATURES• Heating element is heavy-duty steel fins brazed to steel
sheathed tubular elements in a grid pattern that covers the entire discharge area.
• fan delay: on a call for heat, element is energized but fan is delayed until element is warm, eliminating the circulation of cold air during start up. When the thermostat is satisfied, the element is de-energized, but the fan continues until all heated air is discharged providing longer component life and higher comfort level.
• designed for easy installation. Heater is mounted prior to wiring. Both hands are free to make field connections in roomy compartment.
• motor is totally enclosed, impedance protected with perma-nently lubricated bearings.
• airflow system maximizes air volume at minimum noise level; 65 Cfm.
• this heater is designed for installation in 2 x 4 or larger wall sections using the wall box provided. the heater may also be surface mounted to the wall by using the surface mounting frame, model no. CWHsm (order separately).
• includes built-in disconnect switch.
• the heater may be wired with standard building wire (60°). refer to specification chart for correct supply voltage and wire size.
• Built-in snap action thermostat (no radio/tv interference; 40° -85°f).
• northern White durable polyester powder coat finish.
MOUnTinG LiMiTATiOnS1. do not install heater closer than 4" from floor. 2. do not install heater behind towel rack, behind door, in
floor, in ceiling, in closet, or where air flow may be ob-structed.
3. requires 3 wires if remote thermostat is desired.
CWHSM Surface Mounting Frame (Assessory)Order Separately. 12-1/2" H x 10-3/8" W x 4" D
CWHS1 1" Recessed Frame 12-1/2" H x 10-3/8" W x 1" D
aCCessories (oPtional)
Grille: 12½" H x 10-33/8" W x 1" D
Back Box: 11¼" H x 9½" W x 3¾" D
*Factory wired for higher wattage, field convertible to half wattage
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com96
Commercial Wall Heaters – Fan-ForcedType CWH-3000
APPLiCATiOnSfor supplementary heating of offices, reception rooms, game rooms, family rooms and similar light-duty commer-cial and residential applications.
or surface mount• Standard Navajo White Finish• 65 CFM
APPLiCATiOnSQCH type fan forced mounted heaters are designed for dens, base-ments, converted attics, breeze ways, garages, bathrooms, small offices, workshops and similar areas Also adaptable to multiple in-stallations in somewhat larger or odd shaped rooms Grille: 10-1/2"L X 12-1/2"W X 1" D Housing: 9-3/4" L x 11" W x 3-3/4" D
CATALOG NUMBER VOLTAGE **WATTAGE AMPS SHIPPING WT.(LBS.)
Qch1101 120 1000500
8 34 7 10
Qch1151 120 1500750
12 56 3 10
Electric Baseboard Heaters–Type 2500
FEATURES• easily installed without disassembly.• lead wires allow quick field connection to either end of
heater.• easy out knockouts at each end for convenient wiring. • Chimney fin element design for maximum air circulation.
airflow is directed away from walls to help prevent wall soiling.
• Ul listed for installation on wall at floor level with wall-to-wall carpeting. Heater stands unsupported during installation.
• navajo White enamel finish retains attractive appearance and is compatible with all interior decors.
• Pre-notched mounting guide marks for fast and easy installation without disassembling the unit.
• Built-in cable clamp in both wiring compartments to restrain incoming cables without using additional hardware.
• Permanently attached copper grounding wire in each wiring compartment.
APPLiCATiOnSfor use in residential construction such as single family homes, apartments, modular or mobile homes as well as commercial, indus-trial and institutional construction. Use as primary, secondary or supplemental heat for new construction or remodel applications.
cAtAlOG nuMBer
VOlts WAtts lGth. shiP Wt. (lBs.)
25426W 240/208 500/376 2’6" 6 3
2543W 240/208 750/564 3’ 7 5
2544W 240/208 1000/752 4’ 10
2545W 240/208 1250/940 5’ 11 5
2546W 240/208 1500/1128 6’ 14
25126W 120 500 2’6" 6 3
2513W 120 750 3’ 7 5
2514W 120 1000 4’ 10
2515W 120 1250 5’ 11 5
2516W 120 1500 6’ 14
seleCtion CHart - stoCk sizes
cAtAlOGnuMBer
descriPtiOn shiP Wt. (lBs.)
TA1AW SP Thermostat, rated 22A @ 120-277V
1 lb
TA2AW DP Thermostat, rated 22A @ 120-277V
1 lb
aCCessories & Controls for Heaters(installs in either Junct Box)
TA1A, TA2A
** As shipped – Field adjustable to 1/2 wattage Note: Requires two separate leads from heater to field supplies single pole wall thermostat
Dimensions: 6 3/4"H x 2 7/8"D Length varies with model See table
CATALOG NUMBER DESCRIPTION Ship Weight.
QCHSM Surface Mount Sleeve 2 lbs.
aCCessories
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Type CDF-RE enclosures also mount easily into standard 2 x 2 ceiling grids
In the ceiling. . . or on it!
Type CDF ceiling-mounted fan-forced heaters are designed for commer-cial and industrial areas requiring electric fan-forced heat Capacities are 2,000 to 5,000 watts Type CDF-SE surface enclosures are designed to mount flat on the ceiling and extend only six inches into the room Type CDF-RE enclosures have no protrusions outside the recess box, allow-ing the heater to recess only seven inches into ceiling space Mounts into permanent ceiling with trim ring
BUILT-IN FAN DELAY — Space temperature is controlled by a wall or unit-mounted thermostat When the thermostat calls for heat, the heating elements and fan energize When the thermostat is satisfied, the ele-ments shut off, but the fan continues to operate until all of the heated air is discharged This feature avoids exposing the heater to residual heat, thus achieving a high comfort level and longer component life
AUTOMATIC THERMAL CUTOUT — A thermal cutout shuts off the heater in the event of over-heating and reactivates the heater when the temperature returns to normal
MULTIPLE PHASE HEATERS — The 208 and 240 volt heaters can be field converted from single to three-phase operation 277 volt single-phase heater is also available
MULTIPLE WATTAGE HEATER SECTIONS — The 5,000 watt heater can be field converted to 3,800 watts or 2,500 watts, and the
4,000 watt heater is convertible to 3,000 or 2,000 watts
THUMB PINS align and temporarily hold the enclosure cover to the heating section freeing both hands to finish installation
300 CFM of airflow
Phosphatized, Baked Enamel Finish: All sheet metal and extruded aluminum parts, except the back box, are phosphatized, then finished by a baked enamel electrostatic painting process.
Elements: Steel fins are cop-per-brazed to low-watt density, steel-sheathed, tubular heating elements which are arranged in a uniform grid pattern. The grid
covers the entire intake area, resulting in uniform
heating of all discharged
air.Efficient Operation: The five-bladed aluminum fan and the rugged impedance-protected, totally-en-closed motor, achieve efficient operation.
CDFSE Surface Mounting Enclosure Only - To Be Used With Above Heater Section. Dim. 20"L x 16 1/2"W x 5 3/4"D. 10 lbs.
CDFRE Recess Mounting Enclosure Only - To Be Used With Above Heater Sections. Dim. 23 3/4"L x 23 3/4W x 7"D. 18 lbs.
CDFT Thermostat SPST Range 45 to 95˚F. 1 lb.
CDFDS Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 1Ø, 60 Hz. 1 lb.
CDFTK Trim Ring for mounting on permanent ceiling (can not be factory installed). 1 lb.
CDFTR4 208/240V Primary Transformer/24V sec. And 24V holding coil control relay. 1 lb.
CDFTR7 277V Primary Transformer/24V sec. And 24V holding coil control relay. 1 lb.
seleCtion CHart - stoCk sizes
(1) Factory wired for highest wattage, field convertible to lower wattages.
(2) Factory wired 1Ø, field convertible to 3Ø.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 99
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Heat Recovery Ceiling Fans
DUAL PURPOSE
ENERGYCONSERVATION SYSTEM
THE
HEAT-DROPPER®
CONCEPT AND HOW IT WORKSWINTER-Recovers wasted heat by eliminating heat stratification.Trappedwarm air at the ceiling caused by natural heat rise and poor air circulationis equalized by the movement of the massive blade span. Thus ceiling tofloor temperature is equalized.With a heat cost savings of 30k percent, theLEADING EDGE fan system can pay for itself in one year.The eliminationof cold spots increases employee productivity and comfort.
SUMMER-General air recirculation in non air-conditioned buildingscreates a cooling breeze and a “Wind Chill Factor” providing evaporationcooling of the skin surface dropping skin temperature by 6 degrees. TheLEADING EDGE fan system supplements air-conditioned buildings byallowing the thermostat settings to be 8 degrees higher. You’ll feel thecoolness of 72 degrees with the thermostat set on 80 degrees - anincomparable energy savings. Additional advantages, eliminates mold andmildew caused by stagnant air, perfect for high humidity areas. No otherfan has our higher air velocity capabilities. Small fans do not developsufficient CFM to be effective in warm weather.
ENTRAINMENT
(CE
NT
ER
LIN
E)
Only Leading Edge provides university documented performance data.Compare this exclusive data to any other fan available.
COMMERCIALMODELS
56001LC / 56" 120V
56001LC / 56" 120V
56001LC / 56" 120V
INDUSTRIAL &SPECIAL APPLICATIONMODELS
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
7'1"
10'
20'
MO
UN
TIN
GH
EIG
HT
S
TOTAL SQUARE FOOT AREA COVERAGE
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
20'
30'
40'
45'
MO
UN
TIN
GH
EIG
HT
S
AREA COVERAGE SUMMARY BY FAN BY HEIGHT
®
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com100
Heat Recovery Ceiling Fans
Suitable for low
ceiling applications.
U.L. 507 listed.
UL 507 states Ceiling Fans suspended from 7 feet to less than 10 feet (blade height to floor) must have minimum thickness of edge of blade 3/16"
U.S. PATENT# 5,645,403
Provides Superior Air Velocity and Efficiency, The Ideal School Classroom Fans56001LC • 56" Commercial / School Classroom FanDesigned for spacious areas with low ceilings where larger blade diameter span creates maxi-mum air velocity and area coverage at lower RPM’s. Engineered specifically for continuous commercial use with the same manufacturing criteria as our heavy duty industrial line. Ideally suited for classrooms.
Note: Supplied with 24" downrods. Secondary mounting cable supplied.† Effective amount of air volume moved past a plane 20ft. from fan, industry test. All specifications subject to change and improvement.†† Area coverage rated for heat destratification at 20’ blade mounting height.
Maximum continuous operation ambient temperature 105°F
U.S. PATENT# 5,575,624
Maximum Area Coverage at Lowest Total Installed Cost.56001 / 56007 56" Industrial FansEngineered and designed for spacious applications where maximum area coverage is required.
Designed for both winter heat destratification and sum-mertime cooling.
Designed for general applications for above average area coverage and cooling velocity. Ideally suited for factories, gymnasiums, high bay storage facilities.
Powerful, heavy-duty motor for mounting heights to 45 feet.
Note: Supplied with 8" and 24" downrods Secondary mounting cable supplied † Effective amount of air volume moved past a plane 20ft from fan All specifications subject to change and improvement †† Area coverage rated for heat destratification at 20’ blade mounting height Maximum continuous operation ambient temperature 105°F
Blade size Order number Volt Max cfm† area coverage†† shipping Weight
56" 56001lc 120 25,500 3,025 sq ft 24 lbs
Blade size Order number Volt Max cfm† area coverage†† color shipping Weight
56" 56001 120 27,500 3,800 sq ft White 24 lbs
56" 56007 277 26,000 3,800 sq ft White 24 lbs
seleCtion CHart - stoCk sizes
seleCtion CHart - stoCk sizes
Order number item shipping Weight
28001FAN GUARD 62" DIAMETER FOR INDUSTRIAL 56" AND 60" FANS
50 lbs
CeilinG fans aCCessories
Custom models available Consult with factory for information and specifications Use only with heavy-duty / industrial models - Not recommended for low ceiling applications
ceiling Fan GuardFor gymnasiums and public facilities ®
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 101
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Thermostats
Honeywell
Q-Mark
T651A Light Duty LIne Voltage – 8 Amps
T822D 24 Volt – Positive Office Vertical Stat
T874F 2 Stage – 24 Volt
T87F Round – 24 Volt
T100 Line Volt – Single Pole
T200 Line Volt – Double Pole
WR-80 Heavy Duty Line Voltage
WR-1E30S Pilot Duty Only
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com102
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 103
Mis
cella
neou
s
MiscellaneousSupplies and Products
Vibration Isolators 104
Motors 105
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com106
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 107
Youn
g R
egul
ator
s
Young Regulators
Dampers and Controls 108
Remote Cable Controls 108
Socket Wrench 108
Casing and Wire 108
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com108
Casing & WireAPPLiCATiOnSruns between damper and remote contoller. features .054" stainless steel torsion-straightened wire with 3/16" flexible galvanized coil spring casing.
cAtAlOG nuMBer lGth.
BOWden-cW-6 6
BOWden-cW-8 8
BOWden-cW-50 50
Socket WrenchAPPLiCATiOnSfor use with worm gear regulators and Bowden cable controls
cAtAlOG nuMBer lGth.
030-12-sOcket 12"
Remote Cable Controls
Dampers and controls
APPLiCATiOnSfor use with worm gear regulators and Bowden cable controls
Series 270-275 Series 270-301 Series 270-896
cAtAlOG nuMBer
diameter (inches)
5020cc 6
5020cc 8
5020cc 10
5020cc 12
5020cc 14
seleCtion CHart
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 109
Ceru
s In
dust
rial
cAtAlOG nuMBer
diameter (inches)
5020cc 6
5020cc 8
5020cc 10
5020cc 12
5020cc 14
Cerus Industrial
Motor Starters – Models BAS/BAS-1P 110
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com110
Motor Starters - Model BAS
STAnDARD BAS STARTER FEATURES:• Hoa keypad with led status Pilot
lights• voltage & dry Contact inputs for auto
run Command• fireman’s override• damper Control * 1 amp max• Wide range Class 1-30 electronic
overload• flexible Control transformer (CPt)• High reliability Contactors for long life• Combination versions include
disconnect
APPLiCATiOnS:• Ul type 1 for indoor use• locakable cover prevents unauthorized access/
tampering• standard conduit knock-outs top and bottom for easy
installation
Combination Versions include Disconnect:• motor circuit protection disconnect provides branch
and short circuit protection • High interrupting ratings for maximum electrical
systems compatibility • no fuses required - save time and money • locakable handle for safety
STAnDARD SinGLE PHASE STARTER FEATURES• motor circuit protection disconnect provides
branch and short circuit protection • High interrupting ratings for maximum
electrical systems compatibility • no fuses required - save time and money • locakable handle for safety
BaS-1P10 Building Automatic10, 110~240VAC, 0.1–HPHOA, Status, Lockable DisconnectAdjustable Wide Range Overload
maGnetiC H-o-a starters - eleCtroniC overload - nema 1 enClosUre
ComBination maGnetiC H-o-a starter - disConneCt - eleCtroniC overload - nema 1 enClosUre
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 111
Puro
lato
r
Purolator
hi-E 40™ Pleated Filter 112
Defiant® Mark 80D™ Pleat 113
single Phase hPBase part #
120V 230V
1 - 1 1 - 1 BAS1-P
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com112
hi-E 40™ Pleated Filter
introductionPurolator’s hi-E 40 filters are medium efficiency, self-supported, extended surface, pleated air filters
Effective in stand-alone applications or as a pre-filter in place of a disposable, permanent, or media pad/frame filter
Easy to install in new or existing side-access housings, package air handling units, and built-up filter banks
Average efficiency: 25-30%
Average arrestance: 90-93%
MERV7 @ 492 FPM
media and supportMedia: Lofted, non-woven pleated filter media composed of non-dyed cotton and synthetic fibers
Media support: Continuously bonded to a corrosion resistant, expanded metal grid allowing a 96% open face area
Pleat configuration: Formed into aerodynamic, semi-tapered, wedge-shaped pleats expanding its capability to capture con-taminants
Options: High Temperature and Class 1 media available Contact factory for pricing and size information
Available treated with an EPA approved bound antimicrobial agent
suggested Product specifications1 The filter shall be the hi-E 40 as manufactured by Purolator Air
Filtration
2 Air filters shall be (1"), (2"), and (4") deep, medium efficiency, pleated media, disposable panel type
3 The filter media shall be self-extinguishing lofted non-woven, non-dyed, natural cotton and synthetic fibers
4 The filter media shall be bonded to a corrosion resistant, ex-panded metal support grid with a 96% open face area
5 To assure no dirty air bypass, the media grid assembly shall be bonded to all interior surfaces of the frame with solvent-free water based glue
6 The support grid shall be formed into a wedge configuration to optimize use of the filter media
7 To maintain accurate pleat alignment on 4" depth filters, die -cut diagonal frame members shall be bonded to the media pack upstream and downstream
Construction featuresFrame: A moisture-resistant die-cut frame
Assembly: A fully bonded double wall frame combines with the integral corner flaps and forms a rugged, durable filter which will not rack, warp or leak under normal operating conditions To assure no dirty air bypass, the media pack is securely bonded to the periphery of the enclosure frame with solvent-free water based glue
U L Classification: Class 2 approved and listed
Tested in accordance with UL Standard 900 and ASHRAE 52 1 1992 and ASHRAE 52 2
In 4" models, accurate pleat alignment is maintained by die-cut pleat spacers on the upstream side
Recommended operating temperature: < 200°F
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 113
Puro
lato
r
Defiant® Mark 80-D™ Pleat
introductionThe Purolator® DEFIANT ®MARK 80-D™ filters are medium efficiency, self-supported, extended surface, pleated air filters Specifically manufactured for system applications requiring high efficiency, non-shedding media filtration Outperforms similar products with respect to initial efficiency and average efficiency, providing optimum filter service life Effective in single filter ap-plications or as improved pre-filter substitutes for disposables, permanent metal filters or media pad/frame filters Industry ap-plications: Pre-filtration for hospitals, health care facilities, food processing plants, telecommunications, pharmaceutical and semi-conductor manufacturing, etc
Based on ASHRAE Standard 52 1-1992:
Average efficiency: 45-50%
Average arrestance: 90-93%
Based on ASHRAE Test Standard 52 2:
MERV 8 (Minimum Efficiency Reporting Value)
media and supportMedia: Synthetic media made up of continuous hydrophobic fibers that do not absorb moisture, and can withstand turbulent, high velocity conditions
Fibers are thermally bonded to eliminate the need for chemical binders that could promote microbial growth or generate VOCs
Improved overall particle size efficiency due to continuous fiber structure and dual stage electrostatic enhancement that captures an increased amount of smaller particulate than conventional media
Media support: Continuously bonded to a corrosion resistant, expanded metal grid allowing a 96% open face area
Pleat configuration: Formed into aerodynamic, semi-tapered, wedge-shaped pleats expanding its capability to capture con-taminants
Frame: Enclosed in a two-piece, high wet-strength beverage board frame
Assembly: A fully bonded double wall frame combines with the integral corner flaps and forms a rugged, durable filter which will not rack, warp or leak under normal operating conditions
To assure no dirty air bypass, the media pack is securely bonded to the periphery of the enclosure frame with solvent-free water based glue
U L Classification: Class 2 approved and listed Tested in accor-dance with U L Standard 900
In 4" models, accurate pleat alignment is maintained with die-cut pleat spacers on the upstream side
Recommended operating temperature: < 200˚F
suggested Product specifications1 The filter shall be the DEFIANT®MARK 80-D™ as manufac-
tured by Purolator Air Filtration
2 Air filters shall be (1"), (2") and (4") deep, medium efficiency, pleated media, disposable panel type
3 The filter media shall be synthetic DEFIANT® filtration media as brand named to Purolator Air Filtration
4 The filter media shall be bonded to a corrosion-resistant, ex-panded metal support grid with a 96% open face area
5 To assure no dirty air bypass, the media grid assembly shall be bonded to all interior surfaces of the frame with solvent-free water based glue
6 The support gird shall be formed into a wedge configuration to optimize use of the filter media
7 To maintain accurate pleat alignment, die-cut diagonal frame members shall be bonded to the media pack upstream and downstream
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
(1) Width and height dimensions are interchangeable The DEFIANT®MARK 80-D™ and the hi-E 40™ may be installed with pleats running vertical or horizontal (2) Capacity ratings are recommended levels Resistance to airflow data is based on ASHRAE 52 1-1992 Test Method Performance tolerances conform to Section 7 4 of
ARI Standard 850 93 (3) The recommended final operating resistance is typical of systems currently in operation The DEFIANT®MARK 80-D™ and the hi-E 40™ can be operated to higher or
lower final resistance levels without adversely affecting filter efficiency
PerformanCe data: Hi-e 40™
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 115
PerformanCe data: Hi-e 40™
Notes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com116
Notes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
BRUCKER VISIONTo be the customer’s preferred HVAC Manufacturer’s Representative in the Chicago, NW Indiana and Central Illinois markets with top market share positions of our core manufacturers.
CORPORATE STRUCTUREBrucker approaches the HVAC Manufacturer’s Representative market in a dramatically different way in that we are organized into four distinct divisions:
* Engineering Sales * Contractor Sales * Aftermarket Sales * Field Service
Each division within Brucker consists of a dedicated sales and inside support group trained to provide technical product information required to meet our customer’s needs while maintaining the highest levels of service and support.
ENGINEERING SALESBrucker’s Engineering division consists of application sales engineers who focus on our customer’s air movement, air control and air distribution product needs by assisting the professional consulting and mechanical engineers during the design stage of a project. With their technical experience, Brucker’s Engineering staff can provide innovative solutions to meet your air movement specification requirements.
CONTRACTOR SALESBrucker’s Contractor sales staff focuses on meeting the air movement, air control and air distribution needs of our mechanical piping and ventilation contractors. By providing their design build expertise along with high quality service, Brucker’s Contractor sales staff insures a seamless transfer of the project from the design stage to construction phase.
AFTERMARKET SALESBrucker’s Aftermarket Sales group focuses primarily on the filtration needs of building owners and property managers in the commercial, institutional and industrial markets. While the need to provide a healthy indoor environment has become increasingly important, Brucker’s Aftermarket Sales staff can provide solutions to meet indoor air quality specifications through their offering of high-quality filtration products.
FIELD SERVICEBrucker’s Field Service division is comprised of highly experienced technicians that offer check, test, and start-up and support of our products to our customers. Managed by our service coordinator in order to deliver efficient response time, these technicians also possess the training to instruct customers as to the proper use and maintenance of their equipment to ensure a longer service life.
Brucker Company is an HVAC Manufacturer’s Representative in the Midwest that serves the following industries within the Chicago, Central Illinois and Northwest Indiana markets: Mechanical & Ventilation Contractors, Mechanical Engineering Firms, Design Build Contractors, Construction Managers, Service Contractors, Building Managers, and Involved Owners.
Brucker provides engineered solutions to meet your application and specification needs through their comprehensive product offering of high-quality equipment and filtration products. By packaging product with professionalism in the areas of sales and service, Brucker provides exceptional support unparalleled to that of other rep firms.
Brucker Company was founded in 1875. Established as a foundry manufacturer producing steel furnace grates, Brucker diversified, evolved, and engaged in various businesses through the early and mid 1900’s. The development of air conditioning in the United States brought many opportunities to Chicago’s entrepreneurial-based business community, and Brucker Company staked its claim accordingly as an HVAC sales representative and distribution organization.
Brucker has two offices serving the Midwest and over 50 total employees. The company’s corporate headquarters in Elk Grove Village, IL boasts a 30,000 square foot warehouse and distribution facility featuring air distribution and filtration products stocked to meet our customer’s immediate requirements.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment