Top Banner
Titanex SMALL CANNULATED SCREW SYSTEM Next generation. Fully modular.
4

Titanexarchive.vilex.com/html/pdfs/Titanex Brochure_Pages QSD 8...T30-30T-14 T30-32T-14 T30-34T-14 T30-36T-14 T30-38T-14 T30-40T-14 4.0 mm Cannulation = 1.4mm Length = xxT Driver =

Aug 25, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Titanexarchive.vilex.com/html/pdfs/Titanex Brochure_Pages QSD 8...T30-30T-14 T30-32T-14 T30-34T-14 T30-36T-14 T30-38T-14 T30-40T-14 4.0 mm Cannulation = 1.4mm Length = xxT Driver =

Titanex™

S M A L L C A N N U L A T E D S C R E W S Y S T E M

Next generation. Fully modular.

Page 2: Titanexarchive.vilex.com/html/pdfs/Titanex Brochure_Pages QSD 8...T30-30T-14 T30-32T-14 T30-34T-14 T30-36T-14 T30-38T-14 T30-40T-14 4.0 mm Cannulation = 1.4mm Length = xxT Driver =

The Titanex™ Small Cannulated Screw System includes 2.0mm, 3.0mm, and 4.0mm color-coded titanium implants and instrumentation.

Implant-Specific Cannulated InstrumentationColor-coded drill, drill guide,

countersink, and driver for each

implant size offer easier identification

in the operating room.

2mm

3mm

4mm

CANNULATED DRILL

COUNTERSINK

HEXALOBE DRIVER

Page 3: Titanexarchive.vilex.com/html/pdfs/Titanex Brochure_Pages QSD 8...T30-30T-14 T30-32T-14 T30-34T-14 T30-36T-14 T30-38T-14 T30-40T-14 4.0 mm Cannulation = 1.4mm Length = xxT Driver =

Titanex™

SM

AL

L C

AN

NU

LA

TE

D S

CR

EW

SY

ST

EM

SYSTEM ADVANTAGES

• Low head profile cannulated titanium implants with hexalobe drive

• Hexalobe drive provides improved driver engagement and reduced head strippage

• Modular caddy system contains implants and implant-specific washers, guide wires, cannulated drills, countersinks and drivers

• Complete range of implant sizes in 1mm increments in 10mm-20mm lengths

• Self-tapping, self-drilling, and individually hand-sharpened cutting tips

• Quick connect, color-coded instrumentation with ratcheting or non-ratcheting handles

• Optional 150mm guide wires and extended depth gauge

Feel the difference:

Individually hand-sharpened

self-drilling, self-tapping

triple cutting tips

Reverse cutting flutes to

facilitate implant removal

Optimized thread lengths for

osteotomy fixation

Low-profile head eliminates

soft tissue irritation

Hexalobe drive for greater torque

control and engagement

Increased wire cannulation

to 1.4mm for 3.0mm implants

reduces bent wires

Page 4: Titanexarchive.vilex.com/html/pdfs/Titanex Brochure_Pages QSD 8...T30-30T-14 T30-32T-14 T30-34T-14 T30-36T-14 T30-38T-14 T30-40T-14 4.0 mm Cannulation = 1.4mm Length = xxT Driver =

Implant sizingImplant lengths from 10-20mm in 1mm increments. Four implants in 2.0mm and 3.0mm sizes and three implants in 4.0mm sizes are provided in each caddy.

111 Mo�tt Street McMinnville, TN 37110

p: 800.521.5002 f: 866.606.4911

[email protected] www.vilex.com

2.0mm

Cannulation = 0.9mmLength = xxT

Driver = T6

T20-10T-09T20-11T-09T20-12T-09T20-13T-09T20-14T-09T20-15T-09T20-16T-09T20-17T-09T20-18T-09T20-19T-09T20-20T-09T20-21T-09T20-22T-09T20-23T-09T20-24T-09

3.0mm

Cannulation = 1.4mmLength = xxT Driver = T10

T30-10T-14T30-11T-14T30-12T-14T30-13T-14T30-14T-14T30-15T-14T30-16T-14T30-17T-14T30-18T-14T30-19T-14T30-20T-14T30-22T-14T30-24T-14T30-26T-14T30-28T-14T30-30T-14T30-32T-14 T30-34T-14 T30-36T-14T30-38T-14 T30-40T-14

4.0mm

Cannulation = 1.4mmLength = xxT Driver = T10

T40-20T-14T40-22T-14T40-24T-14T40-26T-14T40-28T-14T40-30T-14T40-32T-14T40-34T-14T40-36T-14T40-38T-14T40-40T-14T40-42T-14T40-44T-14T40-46T-14T40-48T-14T40-50T-14T40-52T-14 T40-54T-14 T40-56T-14T40-58T-14 T40-60T-14

Inquire about these other precision engineered extremity solutions from Vilex:

1st MPJ Fusion Plate Nitinex™ MemoryCompression Implant

Statix™ Stabilization System

HammerFUZE™ Hammertoe Compression System