Indura UltraSoft Arc Flash Protective Workwear Arc Flash Protective Garments Accessories Arc Flash Protective Garments CAT 2 Arc Flash Faceshield • Features smoke tint & removable chin guard • Tested to Cat 2A NFPA-70E (10.7cal/cm²) • Fits most hard hats/ helmets • Satisfies AS/NZS 4836:2011 140204BSDERGOS Arc Flash helmet NB: This is NOT a hard hat, it is for arc protection uses only • Using other unrated hard hats will void the arc rating of our face shield • 1000V insulated. Flame retardant 140201-HRP CAT 3 Arc Flash Glove • Arc Flash gloves from DEHN Germany • Cat 4 NFPA (45cal/cm²) – back of hand • Cat 3 NFPA (32.8cal/cm²) – palm Part No. Size D-785796 S D-785797 M D-785798 L Part No. Size D-785799 XL D-785800 XXL CAT 4 Arc Pro Gloves • Arc Flash gloves from Protera woven fabric • Tested to Cat 4 NFPA (40cal/cm²) 0017-40-XL PPE bag black canvas • Durable black canvas PPE gear bag with zip • Triple stitched handles & fade resistant Part No. Size 0021PPE650 650 0021PPE900 900 In support of our policy of continuous product improvement we reserve the right to change materials and specifications without notice. Drawings, where used, are not to scale. All dimensions are in millimetres and sizes given are approximate. Where possible, technical MSDS data sheets are made available on the website. All products should be installed and used in accordance with manufacturer's instructions provided. Warning: products may be the subject of registered designs and patents. Refer to website for terms and conditions on warranty. CAT 3 Switching Coat Proban • Arc Flash garment made from patented Proban fabric (100% permanently treated cotton fabric) • 37cal/cm² Arc Flash rating – no exposed metal • Dual layer 330g/m³ • Permanent FR and Arc Flash rating Switching Coat Proban Part No. Size 91-488-50-S S 91-488-50-M M 91-488-52-L L 91-488-54-XL XL 91-488-56-2XL XXL 91-488-56-3XL 3XL • Arc Flash garments made from a patented Modacrylic fabric (cotton/antistatic/FR blend) • Waterproof and removable winter liner – antistatic • Hi-Viz yellow/navy two-tone • 10kA/1sec Arc Flash Rating Part No. Size 91-561675-48-50 48-50 91-561675-52-54 52-54 91-561675-56-58 56-58 91-561675-60-62 60-62 91-561675-64-66 64-66 Switching Jacket Part No. Size 91-551793-52 52 91-551793-54 54 91-551793-56 56 91-551793-58 58 CAT 2 Shirt Indura Ultrasoft • Rated to 8.7cal/cm² for the life of the shirt • Indura UltraSoft (day/night) shirt • Cat 2 rated, 8.7cal/cm² CAT 2 Trousers Indura UltraSoft • Rated to 8.7cal/cm² for the life of the trousers • Indura UltraSoft (day/night) trousers • Cat 2 rated, 8.7cal/cm² CAT 2 Overalls Indura Ultrasoft • Rated to 8.7cal/cm² for the life of the overalls • Indura UltraSoft (day/night) overalls • Cat 2 rated, 8.7cal/cm² Shirt Part No. Trousers Part No. Size 90-US500-39-DN 90-US501-32AU-DN 39 90-US500-40-DN 90-US501-34AU-DN 40 90-US500-41-DN 90-US501-36AU-DN 41 90-US500-42-DN 90-US501-38AU-DN 42 90-US500-43-DN 90-US501-40AU-DN 43 90-US500-44-DN 90-US501-42AU-DN 44 90-US500-45-DN 90-US501-46AU-DN 45 90-US500-46-DN 46 Part No. Size 90-US502-87R-50-DN 87R 90-US502-92R-52-DN 92R 90-US502-97R-54-DN 97R 90-US502-102R-DN 102R 90-US502-104ST-DN 104ST 90-US502-107R-DN 107R 90-US502-112R-DN 112R 90-US502-112ST-DN 112ST 90-US502-120ST-DN 120ST DEHN Protective Garments feature: • Arc Rated to 33cal/cm 2 (NFPA 70E 2012 Cat 3) • Flame-retardant fasteners & reflective strips • Reinforced stand-up collar (jacket & coat only) • Pockets available for additional knee pads (trousers only) • Useful cargo pockets & adjustable belt (trousers only) Part No. Size D-785769 46 D-785770 48 D-785771 50 D-785772 52 D-785773 54 D-785774 56 D-785775 58 DEHN Protective Trousers Part No. Size D-785779 46 D-785780 48 D-785781 50 D-785782 52 D-785783 54 D-785784 56 D-785785 58 DEHN Protective Coat Part No. Size D-785755 48-50 D-785756 52-54 D-785757 56-58 DEHN Protective Jacket ROFA Arc Flash Garments NEW Arc Flash Protective Garments Part No. Size 91-35950-48-S 48 91-35950-50-M 50 91-35950-52-L 52 91-35950-54-XL 54 91-35950-56-2XL 56 91-35950-58-3XL 58 91-35950-60-4XL 60 91-35950-62-5XL 62 91-35950-66-7XL 66 CAT 2 Undergarments NOMEX • Calculated to Cat 2 (8cal/cm²) Part No. Description & Size 0024B-NOMEX Balaclava – NOMEX IIIA 0024B-UG-S NOMEX Undergarments SML 0024B-UG-L NOMEX Undergarments LG 0024B-UG-XL NOMEX Undergarments MED 0024S-M Socks (MED) 0024S-XL Socks (Extra LG) CAT 2 Overalls NOMEX • Arc Flash and flame retardant garment made from DuPont's patented NOMEX fabric – as used by F1 drivers and fighter pilots • 9.7cal/cm² Arc Flash rating • Permanent antistatic, FR & Arc Flash rating • No exposed metal Part No. Size 91-351337-46-XS 46 91-351337-48-S 48 91-351337-50-M 50 91-351337-52-L 52 91-351337-54-XL 54 91-351337-56-2XL 56 91-351337-58-3XL 58 91-351337-60-4XL 60 91-351337-62-5XL 62 CAT 3 Jacket NOMEX • 19.6cal/cm² Arc Flash rating DL Part No. EXTDL_022013 “PROUDLY DISTRIBUTED BY” LABEL GOES HERE Arc Flash Range ONE FLASH AND YOU’RE
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
guard• Tested to Cat 2A NFPA-70E (10.7cal/cm²)• Fits most hard hats/ helmets• Satisfies AS/NZS 4836:2011
140204BSDERGOS
Arc Flash helmetNB: This is NOT a hard hat, it is for arc protection uses only• Using other unrated hard hats will
void the arc rating of our face shield• 1000V insulated. Flame retardant
140201-HRP
CAT 3 Arc Flash Glove• Arc Flash gloves from DEHN Germany• Cat 4 NFPA (45cal/cm²) – back of hand• Cat 3 NFPA (32.8cal/cm²) – palmPart No. SizeD-785796 SD-785797 MD-785798 L
Part No. SizeD-785799 XLD-785800 XXL
CAT 4 Arc Pro Gloves• Arc Flash gloves from Protera woven fabric• Tested to Cat 4 NFPA (40cal/cm²)
0017-40-XL
PPE bag black canvas• Durable black canvas PPE gear bag with zip• Triple stitched handles & fade resistantPart No. Size0021PPE650 6500021PPE900 900
In support of our policy of continuous product improvement we reserve the right to change materials and specifications without notice. Drawings, where used, are not to scale. All dimensions are in millimetres and sizes given are approximate. Where possible, technical MSDS data sheets are made available on the website. All products should be installed and used in accordance with manufacturer's instructions provided. Warning: products may be the subject of registered designs and patents. Refer to website for terms and conditions on warranty.
CAT 3 Switching Coat Proban
• Arc Flash garment made from patented Proban fabric (100% permanently treated cotton fabric)
• 37cal/cm² Arc Flash rating – no exposed metal
• Dual layer 330g/m³
• Permanent FR and Arc Flash rating
Switching Coat Proban Part No.
Size
91-488-50-S S
91-488-50-M M
91-488-52-L L
91-488-54-XL XL
91-488-56-2XL XXL
91-488-56-3XL 3XL
• Arc Flash garments made from a patented Modacrylic fabric (cotton/antistatic/FR blend)
• Waterproof and removable winter liner – antistatic
• Hi-Viz yellow/navy two-tone
• 10kA/1sec Arc Flash Rating
Part No. Size
91-561675-48-50 48-50
91-561675-52-54 52-54
91-561675-56-58 56-58
91-561675-60-62 60-62
91-561675-64-66 64-66
Switching Jacket Part No.
Size
91-551793-52 52
91-551793-54 54
91-551793-56 56
91-551793-58 58
CAT 2 Shirt Indura Ultrasoft• Rated to 8.7cal/cm² for the life of the shirt• Indura UltraSoft (day/night) shirt• Cat 2 rated, 8.7cal/cm²
CAT 2 Trousers Indura UltraSoft• Rated to 8.7cal/cm² for the life
of the trousers• Indura UltraSoft (day/night) trousers• Cat 2 rated, 8.7cal/cm²
CAT 2 Overalls Indura Ultrasoft• Rated to 8.7cal/cm² for the life
of the overalls• Indura UltraSoft (day/night) overalls• Cat 2 rated, 8.7cal/cm²
What is Arc Flash?An Arc Flash or arc fault happens when electric current flows through air gaps
between conductors, causing a short circuit.
When does it occur?Arc flashes often occur when racking in a breaker, performing switching, due to insulation failure, or accidents caused by touching a test probe to the wrong
surface or slipped (non-insulated) tools.
What makes up an Arc Flash? In its most basic form, an arc is made up of four elements; thermal energy (heat), acoustical energy (sound), pressure wave and debris. Each of these
elements can cause serious injury or death to a person.
The dangerous partThe most dangerous part of an Arc Flash incident is the fact that it creates temperatures high enough to burn skin, but also ignite non Arc rated clothing. Burns due to burning clothing are the most serious, involve large percentages of the body and are more often than not, fatal.
Hand with Arc Flash Burns
Severe Arc Flash injury to inner arm
Hand with Arc Flash burns
Typical Arc flash injuries
For more information on Arc Flash, visit our education site at arcflash.com.au
About Arc Flash
• Test Set Up
• 37cal/cm² or 10kA/1sec rated Arc Flash jacket ready for testing
• The garment has never been worn, however has been laundered industrially 50 times
• The garment is a dual layer Proban construction, of 330gsm per layer
• The initial Arc Flash ignition is anywhere between 9,000º & 20,000º C
• The copper in the switchboard is vaporised and expands to over 40,000 times its solid volume
• Plasma is generated by the arc putting the garment under
immense heat and pressure
• The arc continues for 1 full second, as a result of high fault current and slow trip times
• The manikin is equipped with temperatures sensors, none of which may surpass levels that would cause second degree burns
• The garment cannot break open at all or it will fail the test
• The garment passes this test at 10kA/1sec or 37cal/cm²
• No part of the garment breaks open, and no temp sensor register a second degree burn value
• A worker wearing this garment with other appropriate PPE would have had none, or only minor injuries
• Includes: hood (with helmet), switching coat and leggings
• Not included: Gloves
Face Shield Tested to Level 4 NFPA (44.8Cal/cm²). Green ‘Light Enhancing Tint’ visor by Paulson. Worn in conjunction with a helmet (included)
The set includes: Hood (with helmet), Switching voat & leggings.
NB: Gloves not included
The Rating is ATPV: 44.8cal/cm² (Cat 4)
6
6
7
8
Specially designed fabric NOMEX IIIA by DuPont (205g/m²), 5 layer construction
High visibility stripes Positioned on the arms
and bottom of the suit to enhance visibility.
Gloves Available separately and rated to 44.8cal/cm².
Part No. 0017-40-XL
1
2
3
Extra long trousers Designed to cover work boots and protect them from damage by Arc Flash
Boots Leg protectors include built-in boot covers, meaning any Australian Standard and ASTM voltage rated leather work boot with insulated sole is suitable to use with the suit Part No. 93-33-626-size
Test: ASTM F1959-05 Arc Rated 44.8cal/cm²
4
5
Conducted over 4 hours, the module has been designed to complement your existing work practices to give you a comprehensive understanding of Electrical Safety regarding Arc Flash.
Typical topics covered include lockout, portable earthing, test for dead and NFPA 70E Arc Flash hazard analysis and compliance. NFPA 70E is the industry best practice standard for Arc Flash, and is widely accepted in Australia and New Zealand.
At the end of each segment you are asked to complete a skills assessment before you can move on. After successfully completing the training you receive a certificate and information gift pack from us.
NB: The online Arc Flash training module is not designed to replace existing standards or work place practices. Please refer to your company policies regarding the suitability of the training module.
Boundaries for Arc Flash Protection and Shock - Approach Limits
Unqualified Personnel• PPE & SupervisionQualified Person• Competent for Job• Approved Risk Analysis• Approved Work Procedure• EEWP• Incident Energy Calcs or HRC & PPE
Qualified Person• Competent for Job• Approved Risk Analysis• Approved Work Procedure• EEWP• PPE, Tools & Equipment & No Injuries is Prohibited
Qualified Person• Competent for Job• Contact Work JustificationSpecialised Training• Approved Risk Analysis• Approved Work Procedure• EEWP• PPE, Tools & Equipment
No UnqualifiedPersonnel
No UnqualifiedPersonnel
ExposedEnergisedElectrical
Equipment
UnqualifiedPersonnel• Awareness & Continuously Escorted by Qualified Person
If we look at a shock boundary like the limited approach boundary, we can see that an unqualified person inside has to be continuously escorted by a qualified person.
CAT1From 4-7cal/cm2 Arc Rated (AR). Lightweight and great for all day workwear.
CAT2From 8-25cal/cm2 Arc Rated (AR). Perfect for higher protection all day workwear.
CAT440cal/cm2+ Arc Rated (AR). The highest protection available for absolute peace of mind.
Please refer to NFPA 70E for more information and to make your final clothing choices. Always double check the rating on garment label before use.
Try our free 20-minute online training course about arc flash protection. Go to www.extreme.protraining.com It could bethe smartest 20 minutes you ever spend in your work.
FREE 20 MINUTE LIFEPROTECTION COURSE
CAT3From 26-39cal/cm2 Arc Rated (AR). A lightweight solution for high risk tasks.