Top Banner
No.: DZ1406270418 TEST REPORT Sample Name: Diving light Applicant Name: Shenzhen Yeguang Technology Co., Ltd. Manufacturer: Shenzhen Yeguang Technology Co., Ltd. Supplier: / Buyer: / Shenzhen Yitong Testing Technology Co., Ltd
8

Brinyte’s diving flashlight CASS test report

Jan 11, 2016

Download

Documents

Brinyte

Brinyte’s diving flashlight Copper accelerated acetic acid salt spray(CASS) report.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418

TEST REPORT

Sample Name: Diving light Applicant Name: Shenzhen Yeguang Technology Co., Ltd. Manufacturer: Shenzhen Yeguang Technology Co., Ltd. Supplier: / Buyer: /

Shenzhen Yitong Testing Technology Co., Ltd

Page 2: Brinyte’s diving flashlight CASS test report

TEST REPORT No.: DZ1406270418 Date: Jun 27, 2014 Page 1 Of 7

Applicant Name: Shenzhen Yeguang Technology Co., Ltd. Address: Emerson Building A, 26 Zone, Bao’an District, Shenzhen

City, Guangdong Province, China

Sample Information Sample Name: Diving light

Sample No.: ZH1406230418

Sample Model: /

Sample Size: /

Sample Weight: /

Sample Quantity: 11PCS

Sample Description: Normal

Manufacturer: Shenzhen Yeguang Technology Co., Ltd.

Test Information Test Item: CASS Test

Receive Date: Jun 20, 2014 Testing Date: Jun 24, 2014 to Jun 26, 2014 Preconditioning: /

Test Result Pass.

After the test, there is no appearance damage on all samples by visual

inspection.

Authorized: Checked: Tested:

Page 3: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 2 Of 7

Test Item 1: CASS Test

1. Test Standard: GB/T 10125-2012

2. Test Equipment:

Equipment Name Equipment Model Equipment NO. Calibration

Useful-life

Salt Spray Corrosion

Test Chamber YWX/Q-250 TTS-YQ-064 Jan 20, 2015

3. Test Remark & Notes: Place the samples into the Salt Spray Corrosion Test Chamber, the test

condition is as below:

(1) Mix (5±1)% concentration NaCl and (0.26±0.02)g/L concentration CuCl2·2H2O,

the PH value is 3.1.

(2) The air pressure of the fog chamber is 98kPa, temperature inside the

fog chamber is (50±2)℃. (3) The test duration is 48h.

(4) The quantity of salt fog is 1.2ml/h·80cm2.

(5) Clean the samples with running water and then check them by visual inspection.

Page 4: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 3 Of 7

Appendix: Test Pictures

Pre-test:

Page 5: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 4 Of 7

The Samples

Page 6: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 5 Of 7

Testing:

CASS Test

Post-test:

Page 7: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 6 Of 7

Page 8: Brinyte’s diving flashlight CASS test report

No.: DZ1406270418 Date: Jun 27, 2014 Page 7 Of 7

No appearance damage on all samples