Brief for Baths, Toilets, Bathroom Cabinets, Shower, Heated Towel, Mirrors, Bathroom Accessories Minimum five units of each
Brief for Baths, Toilets, Bathroom Cabinets,
Shower, Heated Towel, Mirrors, Bathroom
Accessories
Minimum five units of each
Section 1 – Baths
Freestanding Bath 1800 x 800 With Skirt
Thickness 8mm
• Width 800mm• Length 1,800mm• Height605mm• Depth 450mm• Finish - White• Pipe Size Required - 220 mm • Supplied with skirt
• UNITS REQUIRED – 5
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, etc.)
BATH WATER SPOUT – DIMENSIONS
• SQUARE DESIGN • UNITS REQUIRED – 5• MUST FIT WITH BATH DESIGNS (PIPE, FLOW, ETC)
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, etc.)
BATH CLICK WASTE – 40mm X 50mm
• UNITS REQUIRED – 5• MUST FIT WITH BATH DESIGNS (PIPE, FLOW, ETC)
TRAP P 40x40 with overflow rubber
• UNITS REQUIRED – 5• MUST FIT WITH BATH DESIGNS (PIPE, FLOW, ETC)
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, etc.)
Section 2 – SINK & VANITY CABINETS
UNITS REQUIRED – 8
WALL HUNG VANITY CABINET & BASIN –900 l x 480 w
Include Basin Mixer – Square Design CLICK WASTE – SLOTTED Universal Rubber P-Trap Reseal
Will consider different designs for drawers.
UNITS REQUIRED – 8
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
WALL HUNG BATHROOM CABINET WITH MIRROR COLOR WHITE MATERIAL – WOOD or COMPOSITE PROPORTIONAL IN SIZE TO VANITY CABINET MUST ACT AND LOOK LIKE A SET WITH THE VANITY CABINET DESIGN
UNITS REQUIRED – 8
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
Section 3 – TOILETS UNITS REQUIRED 8
Wall Hung Toilets –Construction height 101 cmMust be a complete system, ready to install and ready to useInclusive of any piping, valves, required for installation.
UNITS REQUIRED – 8 MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, hinges, etc.)
Section 4 – SHOWER UNITS
SHOWER UNDERTILE MIXER
UNITS REQUIRED 5
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
SHOWER ROSE and SHOWER ARM
SQUARE ROSE; 300mm X 300 mm SHOWER ARM – MIN 400mm MUST FIT WITH SHOWER ROSE
UNITS REQUIRED 5
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
SHOWER CHANNEL COMPLETE – 800mm
Stainless Steel Grate Cover
UNITS REQUIRED 5
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
Section 5 – ACCESSORIES
HEATHED TOWEL RANGE STAINLESS STEEL Straight SQUARE 650 mm X 760 mm
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
UNITS REQUIRED 5
TOWEL RACK – DOUBLE RAIL STAINLESS STEEL – POLISHED Straight SQUARE 650 mmMUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
UNITS REQUIRED 8
PAPER HOLDER with FLAPSTAINLESS STEEL – POLISHED Straight SQUARE MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, etc.)
UNITS REQUIRED 8
SOAP RACK –STAINLESS STEEL – POLISHED Straight
MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
UNITS REQUIRED 8
PAPER HOLDER with FLAPSTAINLESS STEEL – POLISHED Straight SQUARE MUST BE READY TO INSTALL AND WORK: MUST CONTAIN ALL COMPONENTS REQUIRED FOR SIMPLE INSTALLATION. (SCREWS, FITTINGS, PIPING, CLASPS, HINGES, etc.)
UNITS REQUIRED 8