2016 UNDERWATER
BRIDGE INSPECTION REPORT
BRIDGE #
DISTRICT: COUNTY: CITY/TOWNSHIP:
Date of Inspection:
Equipment Used:
Inspected By:
Report Written By:
Report Reviewed By:
Final Report Date:
74539
MSAS 109(BRIDGE) over STRAIGHT RIVER
District 6 Steele Owatonna
05/25/2016
Owens, Garrett; Stuber, Cory
Cory Stuber
City or Municipal Highway AgencyOwner:
MinnesotaSTATE:
-
UNDERWATER SUMMARY 3
UNDERWATER INSPECTION 4
UNDERWATER INSPECTION PROCEDURES 6
STRUCTURE INVENTORY 7
ELEMENTS 8
PICTURES 11
DRAWINGS 14
TABLE OF CONTENTS
PAGE NUMBER
-
Contractor:
(A) Reinspect the submerged substructure units at the normal
maximum recommended (NBIS) interval of sixty (60) months.
Collins Engineers, Inc.
9687Contractor Job Number:
RECOMMENDATIONS
REPORT SUMMARY
UNDERWATER INSPECTION
The substructure units inspected below water at Bridge No.
74539, Piers 1 and 2 and the East Abutment, were found to be in
good condition. The concrete was generally smooth and sound with
random minor vertical cracking noted along the pier shafts and the
abutment breastwall. A localized scour depression was located at
the upstream nose and extended to the upstream quarter of Pier 2.
There was also a light to moderate accumulation of timber debris at
the upstream nose of Pier 2.
(A) The channel bottom consisted of silty sand and 2 foot
diameter and smaller rock with up to 3 inches of probe rod
penetration at Pier 1.
(B) The channel bottom consisted of 2 foot diameter and smaller
rocks and gravel with soft silt infilling at Pier 2.
(C) Random vertical hairline to 1/32 inch wide cracks were
observed along the concrete pier shafts.
(D) Random vertical hairline to 1/16 inch wide cracks were
observed along the East Abutment breast wall.
(E) A 2 foot deep scour depression was observed at the upstream
nose of Pier 2 and extending to the upstream quarter point.
INSPECTION FINDINGS
Page 3 of 15
-
The top of the pier shaft at the north end of Pier 1.Water Level
Reference:
WATERLINE DATUM
Waterline Elevation (feet):
The waterline was approximately 10.2 feet below
reference.Description:
1123.8
4.
Piers 1 and 2 and the East Abutment.Substructure(s)
Inspected:
SUBSTRUCTURE INSPECTION DATA
General Shape:
5.4 Maximum Water Depth at Substructure(s) Inspected (feet):
Piers consist of oblong rectangular shafts with rounded ends and
are supported by steel H-piles encased in the concrete shafts. The
abutment consists of a vertical breastwall with skewed
wingwalls.
Code:Item 62: Culvert:
7
Y 48 05/2016 Code:Item 92B: Underwater Inspection:
Code:
(Minnesota specific codes are used for 92B and 113)
NBIS CODING INFORMATION5.
Item 60: Substructure:
Item 61: Channel and Channel Protection:
7Code:
District 6District:
MSAS 109(BRIDGE)
County:
The superstructure consists of a three-span continuous concrete
structural slab that is 22 inches thick at the midspans and 37
inches thick at the haunches (over the substructure units). The
bridge is supported by two reinforced concrete abutments and two
reinforced concrete piers. The piers are numbered 1 and 2 from west
to east.
Bridge Description:
074 - Steele
Facility Carried:
BRIDGE DATA1.
UNDERWATER INSPECTION
Bridge #:
STRAIGHT RIVER Feature Intersected:
74539
Underwater Visibility (feet):
Sunny, 70o FWeather Conditions:
0.5
3.
1.0 Waterway Velocity (ft/sec):
05/25/2016
Professional Engineer/Team Leader:
INSPECTION DATA2.
Cory, R. Stuber, P.E.
Date of Underwater Inspection:
Garrett R. Owens, P.E.Inspection Diver:
Page 4 of 15
-
Scour 1885 EA 1
210 Reinforced Concrete Pier Wall 113 13LF 100
STRUCTURAL ELEMENT CONDITION RATING
Conditions
6.
N
Bridge is scour critical because abutment or pier foundation is
rated as unstable due to observed scour at bridge site.
Item 113: Scour Critical Bridge: Code:
No (Mark your selection with an X)Yes X
215
CS3 CS4
Reinforced Concrete Abutment 60 1070 LF
CS2ELEM # Unit CS1Element Description Quantity
Page 5 of 15
-
The routine underwater inspection of Bridge 74539 (MSAS 109 over
the Straight River) was completed on May 25, 2016. The underwater
inspection was conducted from shore. The inspection was conducted
by a team consisting of a PE-Diver with a valid MnDOT Team Leader
certification, a backup diver and a dive tender. The inspection
utilized commercial dive equipment and techniques (SSA and/or
SCUBA) in accordance with OSHA regulations. Profiles were taken
along the upstream and downstream faces of the bridge and around
the periphery of substructure units to determine the presence,
location and area of scour.
The bridge elements inspected consisted of Piers 1 and 2 and the
East Abutment. According to the bridge inventory or design
drawings, Piers 1 and 2 were founded on steel H-piles encased in
the concrete shafts. The abutment consists of a vertical breastwall
with skewed wingwalls. Inspection procedures followed FHWA guidance
and the MnDOT Bridge and Structure Inspection Program Manual with
channel bottom probing to search for foundations. The routine
underwater inspection frequency is recommended to remain at a
maximum of 60 months based on those findings and risk factors.
Also, inspection procedures should continue to follow the above
approach and standard guidance with 100% Level I and 10% Level II
intensity efforts.
INSPECTION PROCEDURES
UNDERWATER INSPECTION
Page 6 of 15
-
Spec. Feat.Pier Foundation (Material/Type)
1 - CONCCantilever ID
+ W A T E R W A Y +Number of Spans Historic Status
3 - FTG PILE
Underwater Y 60Culvert Type 3 - FTG PILE
Pinned Asbly. N
05/25/2016
Barrel Length
153.1 ft. Navigation Control
Waterway Opening (sf.) 1537Structure Length
ft. Year Painted
0 - No nav. control on waterwayDeck Width (Out-to-Out) 66.3
+ P A I N T +
APPR: 0 TOTAL:5 - Not eligible
MAIN: 3
Main Span Length 62.0 ft.Drainage Area (sq. mi.) 197.0
B R I D G E D A T A +Main Span Detail
N - NOT REQUIRED+ M I S C.
Appr. Span Type Structure Flared
GR Termini N - NOT REQUIRED
Appr. Guardrail
Main Span Type 2 - Concrete Continuous Median Width On
Bridge
ft. Bridge Railing 1 - MEETS STANDARDS
N - NOT REQUIRED
Main Span Design 09 - Slab Span
ft. GR Transition
Skew 30 RIGHT
Y/N Freq Date
NAbutment Foundation (Material/Type)
1 - CONC Frac. Critical
D E P T H I N S P. +Appr. Span Design
0 - No flare+ I N
Appr. Span Detail Field Conn. ID
Parallel Structure N - No parallel structure
Pier Protection
0 - Not Required
Rating Date 04/07/20147965 sq. ft. Traffic
ft. 50B. Rt 6.00Sidewalk Width 50A. Lt 6.00
Roadway Area (Curb-to-Curb)
Posted Load 0 - Not Required
PostingStructure Area (Out-to-Out) 10151 sq. ft.
DBL:VEH: SEMI:
Rt 28 ARail Type Lt 28 C N - N/AN - N/A B N - N/A
N - Not Applicable Overweight Permit CodesCurb Height Lt
ft. Horizontal 0 - Not Required
0.67 ft. Vertical0.67 ft. Rt
Wear Surf Install Year 1991
sq. ft. Nav. Vert. Lift Bridge Clear. (ft.)
N - STBL - LIM SCOUR
Year 2002Primer Type MN Scour Code
Painted Area
Unsound Paint % Nav. Clr. (ft.)Deck Material 1 - Concrete
Cast-in-Place 0.0Wear Surf Type 4 - Low Slump Concrete
Vert. 0.0 Horiz.
S I G N S +Operating Rating 2 - HS TRUCK
1 - Epoxy Coated Reinforcing + B R I D G E
Inventory Rating 2 - HS TRUCK 25.0
49.0Deck Rebars Install Year 1991
Deck Rebars
Finish TypeWear Course/Fill Depth 0.17 ft.
0 - None
Design Load 9 - HS 25 (OR GREATER)
+ C A P A C I T Y R A T I N G S +Deck Membrane
44 5
Inspector Name Stuber, Cory
Latitude Control Section (TH Only) Status' 3.39 ''
2 - 2-way traffic
Routine Inspection Frequency 24
Sect., Twp., Range
0.8 MI E OF JCT TH 14 Level of Service 1 - MAINLINE
- 20W Roadway Type9 - 107N
Detour Length 1.0 mi.R A T I N G S +
Custodian 04 - City or Municipal Highway Agency
Owner 04 - City or Municipal Highway Agency
Deck 6 Unsound Deck %
C O N D I T I O N13 '
A - Open
Longitude 93 002+00.395 + N B I 49.52 '' Reference Point
Crew
+ I N S P E C T I O N +
Agency Br. No. 183
District 06
Bridge Match ID (TIS) 0 Userkey
MSAS 109(BRIDGE) over STRAIGHT RIVER
Minnesota Structure Inventory Report
Bridge ID: 74539
+ G E N E R A L + + R O A D W A Y +
Date: 08/30/2016
Sufficiency Rating 81.3Roadway Name or Description
109
City Owatonna
Routine Inspection Date 04/15/2015
Desc. Loc.
Township Bridge St. (MSAS 109)
Number
NRoadway O/U Key Route On StructureMaint. Area 6B Structurally
Deficient
NRoute Sys 05 - MSASCounty 074 - Steele Functionally
Obsolete
Lanes
Waterway Adequacy 9Max. Vert. Clear.
ft.Legislative District 26Aft.Potential ABC 2 - N/A ft.
ft.On - Off System Roadway Width 52.00 ft.
Vertical Clearance ft.1 - ON
Underclearances N
Service On 5 - Highway-pedestrian Appr. Surface Width+ S A F E T
Y F E A T U R E S +
5 - Waterway Bridge Roadway Width 52.0
52.0 ft.
Service Under
ft.
51.9 ft. Approach Alignment 8Horizontal Clear.
ft.
ft.+ S T R U C T U R E + Lateral Clearance
HCADT ADTT7
Year Built 1991
MN Year Reconstructed Functional Class
%Channel 7
Substructure
0Superstructure 6
ON 4 UNDER
14641 YEAR 2008BMU Agreement ADT
Structure Evaluation 6If Divided
D I M E N S I O N S +Bridge Plan Location 4 - MUNICIPAL
11/1/1991Deck Geometry 4
NB-EB SB-WBDate Opened to Traffic
+ R D W Y
FHWA Year Reconstructed
MN Temporary Status
14 - Urban - Other Principal Arterial Culvert N
A P P R A I S A L R A T I N G S ++ N B I
Page 7 of 15
-
County:
City:
Township:
Township:Section: Range:
Span Type:
NBI Deck: Super: Sub: Chan: Culv:
Appraisal Ratings - Approach: Waterway:
Required Bridge Signs - Load Posting:
Horizntal:
Traffic:
Vertical:
MN Scour Code:
Open, Posted, Closed:
Location:
Route:
Control Section:
Local Agency Bridge Nbr.:
Ref. Pt.:
Maint. Area:
Length:
Deck Width:
Rdwy. Area/ Pct. Unsnd:
Paint Area/ Pct. Unsnd:
Culvert:
Steele
Owatonna
107N9 20W
2 - Concrete Continuous 1 - Slab
6 6 7 7 N
8 9
0 - Not Required
0 - Not Required
0 - Not Required
N - Not Applicable
N - STBL - LIM SCOUR
0.8 MI E OF JCT TH 14
05 - MSAS 109 002+00.395
6B
153.1
66.3
7965 sq. ft. / %
sq. ft. / %
N/A
A - Open
ft.
ft.
Postings:List:
MINNESOTA BRIDGE INSPECTION REPORT
09/09/2016
Inspector: CO Bridge
BRIDGE 74539 MSAS 109(BRIDGE) OVER STRAIGHT RIVER
Unofficial Structurally Deficient N
NUnofficial Functionally Obsolete
Unofficial Sufficiency Rating 81.3
ELEMNBR ELEMENT NAME INSP. DATE QUANTITY
QTYCS 1
QTYCS 2
QTYCS 3
QTYCS 4REPORT TYPE
Reinforced Concrete Slab 05/25/2016 10151 SF 9948 0 203 038
Underwater
10151 SF 9948 0 203 0Migrated Values
Notes: There are numerous diagonal, transverse, and longitudinal
cracks with leaching. There are three transverse cracks that run
the fullwidth of the slab in span 2. [2013] - 8"x8" spall at the NW
corner of span 1. [2015] - no change
510 - Wearing Surfaces 7965 SF 7806 0 159 0
Notes: Concrete Slab with Cathodic Protection System Notes:
Mn/DOT's Owatonna Bridge Crew sealed all of the deck cracks in
2003. Thereare numerous diagonal, transverse, and longitudinal
cracks with leaching. There are three transverse cracks that run
the full width of the slabin span 2. There is a 6" x 10" spall
along the north curb west end of the deck near the strip seal.
[2015] - 12"x12" spall in the EBL 50' to theeast of the west end of
the slab.
Underwater 05/25/2016
7965 SF 7806 0 159 0Migrated Values
Reinforced Concrete Pier Wall 05/25/2016 113 LF 100 13 0 0210
Underwater
113 LF 100 13 0 0Migrated Values
Notes: Pier 1 - Seven full height vertical cracks in the pier
wall. [2015] - no changePier 2 - Six full height vertical cracks
with staining. No spalls or exposed reinforcement. [2015] - no
change
Reinforced Concrete Abutment 05/25/2016 181 LF 121 60 0 0215
Underwater
181 LF 121 60 0 0Migrated Values
Notes: [2016] Migrator added 40 LF to abutment quantity to
account for wingwalls (CS1:0 CS2:40 CS3:0 CS4:0).West Abutment -
there are nine full height vertical cracks in the abutment. No
spalls or exposed rebar.East Abutment - there are seven full height
vertical cracks in the abutment. No spalls or exposed rebar.[2013]
- surface treatment is failing on both abutments. [2015] - no
change
Wingwall notes: NW Wingwall - there are two vertical cracks with
leaching. {2015] - no changeNE Wingwall - there are two vertical
cracks with leeching. [2013] - 1 diagonal crack at the abutment
[2015] - no changeSE Wingwall - the cork joint between the wingwall
and abutment is deteriorating. There is one short diagonal crack.
[2013] - There are fourshort diagonal cracks. [2015] - no changeSW
Wingwall - there is a diagonal crack at the corner of the bridge
seat. [2015] - no change
Reinforced Concrete Pier Cap 05/25/2016 121 LF 119 2 0 0234
Underwater
121 LF 119 2 0 0Migrated Values
Notes: Minor vertical cracks near center of both pier caps.
[2015] - no change
Strip Seal Expansion Joint 05/25/2016 114 LF 114 0 0 0300
Underwater
114 LF 114 0 0 0Migrated Values
Notes: The strip seals were full of dirt and debris, however
there were no signs of leakage at the bridge seat. [2015] - no
change
Page 8 of 15
-
Pourable Joint Seal 05/25/2016 570 LF 560 10 0 0301
Underwater
570 LF 560 10 0 0Migrated Values
Notes: West Approach Joint - there is 14 linear feet of loss of
adhesion across the joint. There is a 6" spall at the northwest end
of the joint.[2015] - no change
East Approach Joint - there is 14 linear feet of loss of
adhesion across the joint. [2015] - no change
Elastomeric Bearing 05/25/2016 20 EA 20 0 0 0310 Underwater
20 EA 20 0 0 0Migrated Values
Notes: The elastomeric bearings are located at the abutments and
are functioning as intended. [2015] - no change
Reinforced Concrete Approach Slab 05/25/2016 2080 SF 0 2080 0
0321 Underwater
2080 SF 0 2080 0 0Migrated Values
Notes: [2016] Migrator assumed an approach slab length of 20FT
and used the inventory quantity of 52FT for the width.East End -
there are four full length cracks in the approach panel. There are
no signs of settlement. [2015] - no change
West End - there are four full length cracks and one transverse
crack in the approach panel. There are no signs of settlement.
[2015] - nochange
Metal Bridge Railing 05/25/2016 351 LF 289 62 0 0330
Underwater
351 LF 289 62 0 0Migrated Values
Notes: [2016] Migrator assumed concrete/metal combination type
rail.The railing consists of solid concrete rail with painted steel
rail on top. There are scattered vertical cracks with rust staining
in the concrete railsections. The steel railing has scattered
scrapes and chips in the paint with small areas of surface
corrosion. [2013] - 1 bolt is missing on thenorth side, 4th section
from the west. [2015] - no change
515 - Steel Protective Coating 999 SF 999 0 0 0
Notes: [2016] Migrator assumed CS1 and a quantity of 999 SF.
Underwater 05/25/2016
999 SF 999 0 0 0Migrated Values
Reinforced Concrete Bridge Railing 05/25/2016 351 LF 289 62 0
0331 Underwater
351 LF 289 62 0 0Migrated Values
Notes: [2016] Migrator assumed concrete/metal combination type
rail.The railing consists of solid concrete rail with painted steel
rail on top. There are scattered vertical cracks with rust staining
in the concrete railsections. The steel railing has scattered
scrapes and chips in the paint with small areas of surface
corrosion. [2013] - 1 bolt is missing on thenorth side, 4th section
from the west. [2015] - no change
Critical Deficiencies or Safety Hazards 05/25/2016 1 EA 1 0 0
0800 Underwater
1 EA 1 0 0 0Migrated Values
Notes: [2015] - No critical findings were observed during this
inspection.
Concrete Decks - Cracking & Sealing 05/25/2016 0 LF 0 0 0
0810 Underwater
0 LF 0 0 0 0Migrated Values
Notes: Mn/DOT's Owatonna Bridge Crew sealed all of the deck
cracks in 2003. The majority of the cracks have reopened. [2015] -
cracks areunsealed.
Plow Fingers 05/25/2016 1 EA 0 1 0 0815 Underwater
1 EA 0 1 0 0Migrated Values
Notes: There are ten missing plowstraps on the west end of the
bridge. [2015] - no change
Scour 05/25/2016 1 EA 0 1 0 0885 Underwater
Notes: [2016] Underwater Inspection - A 2 foot deep scour
depression was observed at the upstream nose of Pier 2 and
extending to theupstream .
Slopes & Slope Protection 05/25/2016 1 EA 1 0 0 0892
Underwater
1 EA 1 0 0 0Migrated Values
Notes: All of the slopes are well protected. [2015] - no
change
ELEMNBR ELEMENT NAME INSP. DATE QUANTITY
QTYCS 1
QTYCS 2
QTYCS 3
QTYCS 4
BRIDGE 74539 MSAS 109(BRIDGE) OVER STRAIGHT RIVER
REPORT TYPE
Page 9 of 15
-
Deck & Approach Drainage 05/25/2016 1 EA 1 0 0 0894
Underwater
1 EA 1 0 0 0Migrated Values
Notes: The deck drainage system is functioning as intended.
[2015] - no change
Sidewalk, Curb, & Median 05/25/2016 1 EA 0 1 0 0895
Underwater
1 EA 0 1 0 0Migrated Values
Notes: Mn/DOT's Owatonna Bridge Crew sealed all of the sidewalk
cracks in 2003. There is a 6" x 10" delaminated area in the curb at
the NWcorner adjacent to the strip seal joint. [2013] - The
majority of cracks have reopened. [2015] - SE corner of
rail/sidewalk has a minor area oferosion.
Miscellaneous Items 05/25/2016 1 EA 1 0 0 0899 Underwater
1 EA 1 0 0 0Migrated Values
Notes: There are no swallow nests on the bridge. There is a
utility line firmly attached to the face of the east abutment and
along the southeastwingwall. This line continues along the north
side of the slab and goes underground at the end of the northwest
wingwall. The utility cover plateis broken off at the northwest
corner behind the rail post. [2015] - no change
Protected Species 05/25/2016 1 EA 1 0 0 0900 Underwater
1 EA 1 0 0 0Migrated Values
Notes: Use this element to track the presence of protected
species living on this structure.
General Notes:
Inspector's Signature Reviewer's Signature
Cory Stuber
Inventory Notes:
After the flooding of September 2010, BR74539 was inspected for
evidence of flood related damage. No significant floodrelated
issues were found.
Channel - NBI 7 Minor bank erosion both sides of the bridge.
[2011] - inspected by Steve Miller and Robert Pyfferoen.
(snooped)[2013] - inspected by Tom Miles[2015] - inspected by Aaron
Forthun
58. Deck NBI:
36A. Brdg Railings NBI:
36B. Transitions NBI:
36C. Appr Guardrail NBI:
36D. Appr GuardrailTerminal NBI:
59. Superstructure NBI:
60. Substructure NBI:
61. Channel NBI:
62. Culvert NBI:
71. Waterway Adeq NBI:
72. Appr RoadwayAlignment NBI:
[2015] - moderate cracking with minor spalling
[2015] - moderate cracking
[2015] - minor cracking
[2015] - minor bank erosion
[2015] - no speed reduction required
ELEMNBR ELEMENT NAME INSP. DATE QUANTITY
QTYCS 1
QTYCS 2
QTYCS 3
QTYCS 4
BRIDGE 74539 MSAS 109(BRIDGE) OVER STRAIGHT RIVER
REPORT TYPE
Page 10 of 15
-
Photo 1 - Typical View of South Elevation, Looking North
Photo 2 - Typical View of North Elevation, Looking South
Pictures
Page 11 of 15
-
Pictures
Photo 3 - Typical View of Pier 1, Looking North
Photo 4 - View of East Abutment, Looking Northeast
Page 12 of 15
-
Pictures
Photo 5 - View of West Bank, Looking North
Page 13 of 15
-
Figure No.: 1
Scale: NTS
Legend
UNDERWATER BRIDGE INSPECTION
DEPARTMENT OF TRANSPORTATION
MINNESOTA
INSPECTION AND SOUNDING PLAN
TYPICAL END VIEW OF EACH PIER SECTION
Timber Debris
46'-0"
West
Abutm
ent
East
Abutm
ent
Pier 1
Pier 2
2
2
3
2
3
1Flo
w
River
Straig
ht
SOUNDING PLAN
62'-0" 46'-0"N
4
-0.4
-0.4
Date: June, 2016Drawn By: BGDO
Checked By: BRL
Sounding Depth (5/25/16)
-2.6
-2.6
-2.0
-2.5
-2.3
-2.2 -
3.4
-3.5
-3.2
-3.0
-4.1
-3.0
-1.6
-5.4
-4.3
-3.0
-1.6
-0.4-0
.7-1.2-1
.4-1.7-1
.1
-2.9
-4.2
-4.4
-3.7
-5.3
-4.0
-2.0
-6.4
-2.9
-4.3
-1.1
-1.7
-1.5
-1.5
-1.4
-1.2
5
CITY OF OWATONNA, STEELE COUNTY
MSAS 109 OVER THE STRAIGHT RIVER
STRUCTURE NO. 74539
Project: 63-9687
Sounding Depth (9/12/12)
1599 Selby Avenue
Suite 206
St. Paul, MN, 55104
(651) 646-8502
www.collinsengr.com
-1.8
-0.6
-0.5
-0.7
substructure units as well as around the pier structures.
Soundings were taken parallel to the bridge at 1/4 point
intervals between the4.
in feet.
Soundings indicate the water depth at the time of inspection and
are measured 3.
This corresponds to a waterline elevation of 1123.8 feet.
approximately 10.2 feet below the top of shaft at Pier 1 on the
upstream end.
At the time of inspection, on June 25, 2016 the waterline was
located2.
The East Abutment and Piers 1 and 2 were inspected underwater.
1.
GENERAL NOTES:
Shorline (Typ.)
-3.5
-.-
-.-
-0.8
-5.4
-.-
-5.0
-.-
-2.4
-.-
-4.5
-.-
extended to the upstream 1/4 of Pier 2.
2 foot deep scour depression was observed at the upstream nose
and 5
East Abutment breast wall.
Random vertical hairline to 1/16 inch wide cracks were observed
along the 4
concrete pier shafts.
Random vertical hairline to 1/32 inch wide cracks were observed
along the 3
with soft silt infilling at Pier 2.
The channel bottom consisted of 2 foot diameter and smaller
rocks and gravel 2
rock with up to 3 inches of probe rod penetration at Pier 1.
The channel bottom consisted of silty sand and 2 foot diameter
and smaller 1
INSPECTION NOTES:
Top of Shaft
10.2
Page 14 of 15
-
UPSTREAM FASCIA PROFILE
DOWNSTREAM FASCIA PROFILE
Figure No.: 2
UNDERWATER BRIDGE INSPECTION
DEPARTMENT OF TRANSPORTATION
MINNESOTA
UPSTREAM AND DOWNSTREAMFASCIA PROFILES
Scale: 1"=20'
Refer to Figure 1 for General Notes.
Note:
~ Brg. West Abutment ~ Brg. East Abutment
~ Pier 2~ Pier 1
W.L. El. 1123.8
1140
1120
1100
1160
1140
1120
1100
1160
~ Brg. West Abutment ~ Brg. East Abutment
~ Pier 2~ Pier 1
1140
1120
1100
1160
1140
1120
1100
1160
W.L. El. 1123.8
46'-0" 62'-0" 46'-0"
46'-0" 62'-0" 46'-0"
El. 1113.20 El. 1113.75
El. 1113.20 El. 1113.75
El. 1113.75
El. 1114.00
El. 1114.00
Date: JUNE, 2016Drawn By: BGDO
Checked By: BRL
on 9/12/12
Channel Bottom
on 9/12/12
Channel Bottom
CITY OF OWATONNA, STEELE COUNTY
MSAS 109 OVER THE STRAIGHT RIVER
STRUCTURE NO. 74539
Shoreline
Shoreline
Shoreline
Project: 63-9687
1599 Selby Avenue
Suite 206
St. Paul, MN, 55104
(651) 646-8502
www.collinsengr.com
on 5/25/16
Channel Bottom
Shorelineon 5/25/16
Channel Bottom
Page 15 of 15
CoverTable of ContentsUnderwater SummaryUnderwater
InspectionUnderwater Inspection ProceduresStructure
InventoryElementsPicturesDrawings