breathing star BSP-MT 1-8 Efficient Compressed Air Treatment System for Industrial and Medical Breathing-air Short Description BSP-MT1-8 heatless adsorption dryers with integral purification and catalytic stages are designed to treat com- pressed air reliably and efficiently to meet the medical breathing air requi- rements of the European Pharmacopia and other relevant specifications. The units are constructed in a compact manner and designed to be free-stan- ding. They are equipped with built-on pre- and after filtration and are sized for volumetric flows of up to 139 m³/h (suction capacity of the compressor referring to a compression of 13 bar e ). Compressed air first enters the va- lidated GL pre-filter into one of two twin-profiles; both filled with a speci- fic drying-agent. One chamber dries and removes harmful vapours from the compressed air while the other chamber undergoes regeneration. At the start of the drying-cycle, this chamber is open to atmosphere and a small proportion of dried compressed air passes through the adsorption bed, transporting the humidity and harmful vapours out. When this procedure is complete, the vessel is re-pressurised in readiness to repeat the drying procedure. Continuous, uninterrup- ted operation is maintained utilising so-called pressure-swing technology together with individually operated main- and exhaust valves. Scope of supply: Breathing-air treatment system with GL pre- and after filtration; available with optional dew-point dependant switching (DDS). Dry compressed air subsequently enters the integral purification and catalytic stage where oil-vapour, odours, gaseous vapours and traces of carbon-monoxide are reliably remo- ved. Finally, the clean, treated air exits via the validated GL after-filter into the downstream compressed air network. The BSP-MT1-8 Breathing-air treat- ment system operates a fixed, timed changeover-cycle between the two dryer chambers. Where the applica- tion requires additional monitoring, the installation of a dew point sensor is available as an option: The chosen pressure dew point settings (changeo- ver set-point) allow the changeover times of the individual vessels to be adjusted to meet operating require- ments whilst providing reliable mo- nitoring of the dryers performance. An adjustable alarm is available via voltage-free signal.
4
Embed
breathing star BSP-MT 1-8 BSP-MT 1-8.pdf · GUS TR (formerly GOST-R) Pressure vessel approvals Modell Order No. Volumetric flow1) in m3/h Nominal pipe size2) 1. Pre-filter 2. Pre-filter
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
breathing star BSP-MT 1-8Efficient Compressed Air Treatment System for Industrial and Medical Breathing-air
Short Description BSP-MT1-8 heatless adsorption dryers with integral purification and catalytic stages are designed to treat com-pressed air reliably and efficiently to meet the medical breathing air requi-rements of the European Pharmacopia and other relevant specifications. The units are constructed in a compact manner and designed to be free-stan-ding. They are equipped with built-on pre- and after filtration and are sized for volumetric flows of up to 139 m³/h (suction capacity of the compressor referring to a compression of 13 bare).
Compressed air first enters the va-lidated GL pre-filter into one of two twin-profiles; both filled with a speci-fic drying-agent. One chamber dries and removes harmful vapours from the compressed air while the other chamber undergoes regeneration. At the start of the drying-cycle, this chamber is open to atmosphere and a small proportion of dried compressed air passes through the adsorption bed, transporting the humidity and harmful vapours out. When this procedure is complete, the vessel is re-pressurised in readiness to repeat the drying procedure. Continuous, uninterrup-ted operation is maintained utilising so-called pressure-swing technology together with individually operated main- and exhaust valves.
Scope of supply:Breathing-air treatment system with GL pre- and after filtration; available with optional dew-point dependant switching (DDS).
Dry compressed air subsequently enters the integral purification and catalytic stage where oil-vapour, odours, gaseous vapours and traces of carbon-monoxide are reliably remo-ved. Finally, the clean, treated air exits via the validated GL after-filter into the downstream compressed air network.
The BSP-MT1-8 Breathing-air treat-ment system operates a fixed, timed changeover-cycle between the two
dryer chambers. Where the applica-tion requires additional monitoring, the installation of a dew point sensor is available as an option: The chosen pressure dew point settings (changeo-ver set-point) allow the changeover times of the individual vessels to be adjusted to meet operating require-ments whilst providing reliable mo-nitoring of the dryers performance. An adjustable alarm is available via voltage-free signal.
Product SpecificationBreathing Star BSP-MT 1-8 for Industrial & Medical Breathing Air
Mains Voltage 230 V, 50-60 Hz
Alternative Voltage 115 V, 50-60 Hz and 24 V DC
Protection class IP65
Electrical connections
Site Selection frost-free indoor installation in a non-hazardous environment
Ambient Temperature 1.5 to 50 °C
Compressed air inlet temperature 25 to 50 °C
Operating pressure 5 to 16 bare
Medium Compressed air
Operating Range
Pressure dewpointat 7 bare
Changeover point: -45 °C ex-factory setting; Adjustable via the menu from -25 to -50 °C in 5 °C. stepsAlarm set-point: -40 °C ex-factory setting; always 5 °C above the changeover-point.
Optional dew point sensor ZHM100
Filters See product-specification regarding GL filter ref: ZL and XL
Pressure vessels Aluminium
Valve blocks Aluminium
Seals NBR
Dryer Filling Mixture of aluminium-silicates and activated alumina
Purifier Filling Mixture of activated carbon and catalyst
Materials of construction
EU Approval for fluid group 2 in accordance with the Pressure Equipment Directive 97/23/EC Product range BSP-MT 1 and 2 in accordance with article 3, paragraph 3; Product range BSP-MT 3 to 8 in accordance with category I (Module A).
1) m³/h, relating to 1 bara and 20 °C at the compressor suction capacity. Subsequently compressed to 13 bare and 35 °C inlet temperature to the dryer at 100% relative humidity – for pressure dewpoint of -40 °C.2) In accordance with DIN ISO 228 (BSP-P); Alternative ANSI B 1.20.1 (NPT-F)
Product SpecificationBreathing Star BSP-MT 1-8 for Industrial & Medical Breathing Air
Model A B C D E Weight
BSP-MT 1 533 400 216 217 101 16.5
BSP-MT 2 533 575 216 217 101 21.5
BSP-MT 3 533 825 216 217 101 29.0
BSP-MT 4 533 1075 216 217 101 36.0
BSP-MT 6 736 1203 300 255 132 75.0
BSP-MT 7 736 1428 300 255 132 85.0
BSP-MT 8 736 1628 300 255 132 97.0
Dimensions in mm, Weight in kg
Development/Manufacture DIN EN ISO 9001, DIN EN ISO 14001
Quality Assurance
Example: maximum inlet volumetric flow of 32 m³/h at a minimum pressure of 11 bare and 40 °C inlet temperature: 32 m³/h : 0.64 = 50 m³/h – Suitable Model BSP-MT 4.
Minimum operat-ing pressure in bare
Breathing-air system – Inlet temperature in °C
25 30 35 40 45 50
5 0.47 0.46 0.44 0.40 0.36 0.34
6 0.55 0.54 0.52 0.45 0.40 0.38
7 0.63 0.62 0.60 0.50 0.44 0.43
8 0.72 0.70 0.68 0.60 0.54 0.52
9 0.79 0.78 0.75 0.63 0.60 0.55
10 0.87 0.86 0.80 0.65 0.63 0.61
11 0.80 0.79 0.75 0.64 0.61 0.59
12 0.92 0.91 0.89 0.78 0.73 0.67
13 1.03 1.02 1.00 0.91 0.82 0.79
14 1.16 1.15 1.13 1.00 0.94 0.86
15 1.30 1.28 1.26 1.08 1.03 0.99
Correction factor (f) in accordance with the actual minimum operating pressure in bare
B D
E
A C
Industrial breathing-airBSP-MT
Breathing-air unit
Medical air
Europe UK USA Australia Europe
EN 12021 BS 4275 ANSI/CGA AS 1715 European Pharmacopia
Despacs: Required quantity of adsorption material pacs per model for preventative maintenance after 12 months
Accessories
EMEA Product Information CentreFree phone: 00 800 27 27 5374(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)
US Product Information CentreToll-free number: 1-800-27 27 537
www.parker.com
Product SpecificationBreathing Star BSP-MT 1-8 for Industrial & Medical Breathing Air