Top Banner
Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit 1b, Sovereign Court 2, University of Warwick Science Park, Sir William Lyons Road, Coventry CV4 7EZ Tel: +44 (0)24 7669 0900 Fax: +44 (0)24 7669 0274 Email: [email protected] Web: www.tmsconsultancy.co.uk
8

Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Apr 04, 2018

Download

Documents

lytram
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP

TMS reference no: 10820

Unit 1b, Sovereign Court 2,

University of Warwick Science Park,

Sir William Lyons Road, Coventry CV4 7EZ

Tel: +44 (0)24 7669 0900

Fax: +44 (0)24 7669 0274

Email: [email protected]

Web: www.tmsconsultancy.co.uk

Page 2: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 S:\Safety Audits\UK\WSP\Branston Depot, Burton Road, Branston\RSA1\Report\Branston Depot, Burton Road, Branston RSA1.docx

1

Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1

1. Introduction 1.1 This report describes a Stage 1 Road Safety Audit carried out on a

proposed ghost island right turn lane on Burton Road, Branston, on behalf of WSP. The audit was carried out on 22nd March 2013 in the offices of TMS Consultancy.

1.2 The audit team members were as follows:-

Andy Paul - BEng (Hons), MCIHT, MSoRSA Associate, TMS Consultancy Darren Newbold – MSc, BSc (Hons), MCIHT, MSoRSA Engineer, TMS Consultancy

1.3 The audit comprised an examination of the drawings and other information

relating to the scheme supplied by the design office, which is listed in Appendix A. The site was visited by the Audit Team on 21st March 2013. The weather was cloudy and dry. Traffic flows were moderate. Pedestrian and cycle flows were light.

1.4 The terms of reference of the audit are as described in HD 19/03. The

team has examined and reported only on the road safety implications of the scheme as presented and has not examined or verified the compliance of the design to any other criteria.

1.5 All of the problems described in this report are considered by the audit

team to require action in order to improve the safety of the scheme and minimise accident occurrence. The locations of specific problems are referenced on the plan in Appendix B.

1.6 The scheme consists of a proposed ghost island right turn lane on Burton

Road, Branston at the access of the existing Branston Depot Access. The new access will be for a mixed use development. A pedestrian crossing refuge island will be provided to the east of the access.

Page 3: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 S:\Safety Audits\UK\WSP\Branston Depot, Burton Road, Branston\RSA1\Report\Branston Depot, Burton Road, Branston RSA1.docx

2

2. Items resulting from this Stage 1 Audit 2.1 PROBLEM

Location – Burton Road - Pedestrian Crossing Point

Summary: Potential vehicle to pedestrian conflict Stationary buses at the bus stop will overhang the pedestrian crossing point on the north side of Burton Road, which will prevent pedestrians being able to use the crossing whilst the bus remains. This may result in pedestrians having to negotiate crossing Burton Road at other locations (i.e. close to the taper to the right turn lane) which may result in a greater potential for vehicle to pedestrian conflict.

RECOMMENDATION The bus stop should be relocated further east.

Page 4: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 S:\Safety Audits\UK\WSP\Branston Depot, Burton Road, Branston\RSA1\Report\Branston Depot, Burton Road, Branston RSA1.docx

3

2.2 OTHER ISSUES 1) The width of tactile paving on the footway on either side of the access

junction does not mirror the width of the pedestrian area on the refuge island. At detailed design stage the width of the crossing points and tactile paving should match the width of the pedestrian area in the refuge island. In addition, tactile paving should be provided in the refuge island.

2) There is a polished and slightly sunken service cover in the westbound running lane on Burton Road that may be within the right turn lane area. This may be a slip hazard to vehicles making right turn manoeuvres into the access. At detailed design stage the service cover should be repaired and made flush with the carriageway. A non-slip surface should be applied to the cover with a similar skid resistance to the surrounding carriageway.

3) The general carriageway surface condition in places on Burton Road and within the access is poor. The junction should be resurfaced as part of the works.

Page 5: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 S:\Safety Audits\UK\WSP\Branston Depot, Burton Road, Branston\RSA1\Report\Branston Depot, Burton Road, Branston RSA1.docx

4

3. Audit Team Statement I certify that the terms of reference of the audit are as described in

HD 19/03.

Audit Team Leader Darren Newbold – MSc, BSc (Hons), MCIHT, MSoRSA Engineer, TMS Consultancy Signed ....................................................

Date ............22nd March 2013.........…

Audit Team Member

Andy Paul - BEng (Hons), MCIHT, MSoRSA Associate, TMS Consultancy TMS Consultancy Unit 1b, Sovereign Court 2, University of Warwick Science Park Sir William Lyons Road Coventry CV4 7EZ ℡ + 44 (0)24 7669 0900

� + 44 (0)24 7669 0274 � [email protected] � www.tmsconsultancy.co.uk

Page 6: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 Appendix A

Appendix A List of Drawings Examined: Drawing No. 0078/SK/005 Rev A (original design) Drawing No. 0078/SK/004 Rev A Drawing No. 0078/SK/011 Rev A (scheme incorporating designers response)

Other Information Provided:

Road Safety Audit Brief

Page 7: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

Road Safety Audit Stage 1 Appendix B

Appendix B

Please refer to the following page for a plan illustrating the locations of the problems identified as part of this audit (location numbers refer to paragraph

numbers in the report).

Page 8: Branston Depot, Burton Road, Branston RSA1 Application/622000/6224… · Branston Depot, Burton Road, Branston Road Safety Audit Stage 1 on behalf of WSP TMS reference no: 10820 Unit

Client: WSP

Scheme: Branston Depot, Burton Road, Branston

2.1

2.2 (1)

2.2 (2)

2.2 (3)