Top Banner
Systems overview Calibration systems
12

BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

Mar 17, 2018

Download

Documents

trinhdien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

Systems overview

Calibration systems

Page 2: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

2

About us

In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within the calibration market, we deliver the ideal solution for each measurement task. Among these brands, Scandura enjoys a special reputation for complete calibration systems and for valve test benches. These are available in diff erent designs and levels of automation.

A division of the WIKA group

Page 3: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

33

Your competent partner for calibration systemsEffi ciency in maintenance and calibration can increase when these activities are realized in an ideal working environment. Any laboratory or workshop will benefi t from these bench solutions, from the harsh environment of the off shore oil & gas industry to desalination plants, from refi neries to power generation plants.

Our bench concept is designed to take into account the fl exibility and the expansion possibilities.

We off er complete systems from simple workbenches to complex applications featuring automatic calibrations (ISO 9000 compliant).

Calibration modules cover electronic signals, temperature, loop and pressure applications. Power supplies, multimeters, oscilloscopes and generator modules can also be fi tted into the bench consoles.

A wide range of modules can be fi tted to the console creating a highly fl exible system that is both functional and easy to use.

The robust design and the high quality of the installed components guarantee areliable and long-lasting performance of the calibration benches.

Functions are clearly defi ned on each module and a competent technician will be able to operate the system without training or constant reference to manuals.

Versatile Robust Easy to use

Page 4: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

4

Width 3,000 mmDepth 1,200 mmHeight 2,080 mmWorking surface height 945 mm

Main features

■ Pressure generation and measurement available from vacuum to 1,200 bar

■ Electrical section to generate and measure the electri-cal parameters normally used in the fi eld of industrial instrumentation(mA/mV/V/Ω) and the most common AC/DC supplies

Typical dimensions

Model CBS-SC2000Integrated calibration system for electronic and pneumatic instrumentation

Typical applications are the calibration and testing of pneumatic and electronic industrial instrumentation against pressure primary standards traceable to national standards.

System CBS-SC2000 is the heart of a well-organised central instrument workshop.

The systems CBS-SC2000 can be used for a wide range of applications. Using the quick fi t connectors and external connections, the operator can set up a large variety of pneumatic and electrical circuits.

Page 5: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

5

System description

Model CBS-SC4000Integrated temperature test and calibration bench

The CBS-SC4000 ensures the exhaustive testing and verifi cation capabilities to almost any type of temperature measuring instrument, regardless of their principle of operations: mechanical, pneumatic or electronic.

Typical applications are the testing and calibration of temperature measuring instruments such as: mercury thermometers, thermocouples, NTC/PTC, thermistors, Resistance Temperature Detectors (RTD), thermostats,

pneumatic and electronic transmitters, temperature controllers and temperature recorders.

System CBS-SC4000 allows calibration procedures tobe carried out by using the comparison method, as mostdemanding international standards require.

For complete specifi cations, please refer to data sheet CT 92.33.

Main features

■ Calibration of temperature instruments by comparison with the reference thermometers supplied with each bath

■ The systems can be based on 1, 2, 3 and 4 baths ■ Temperature ranges from – 40 ... +600 °C

System CBS-SC4000-1Single bath / (W x D x H) 550 x 420 x 960 mmSystem CBS-SC4000-2Two baths / (W x D x H) 1,150 x 850 x 1,260 mmSystem CBS-SC4000-3Three baths / (W x D x H) 1,800 x 850 x 1,260 mmSystem CBS-SC4000-4Four baths / (W x D x H) 2,400 x 850 x 1,260 mm

Typical dimensions

Page 6: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

6

The CBS-SC5000 is suitable to check electric/electronic instruments and devices, providing the operator with a wide variety of AC and DC supplies and facilities to enable accurate measurements of the most common electric parameters.

Width 554 mmDepth 450 mmHeight 711 mm

Main features

■ 19" modular construction for table operation; modules may be joined (or splitted) at any time with minor modifi cations.

■ Aluminium structure with painted steel plates on sides, top and rear; front panels are made of anodised aluminium with engraved mimics.

■ Air set for cleaning purposes, including pressure reducer, gauge and fl exible hose with air jet.

Typical dimensions

Model CBS-SC5000Integrated calibration system for electric instrumentation

Instruments checked with system CBS-SC5000 includeDC-powered electronic transmitters/converters, AC-powered controllers, recorders and AC / DC instruments like pressure and temperature switches, solenoid valves, relays, etc.

For complete specifi cations, please refer to data sheet CT 92.34.

Page 7: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

7

System description

Model CBS-SC9000Integrated temperature test and calibration bench

The CBS-SC9000 is a multi-purpose calibration station that features a single 19’’ table-top rack incorporating everything necessary to ensure the exhaustive calibration of a wide range of process instruments and sensors.

The CBS-SC9000 is very easy to use and shortensthe way and the time required to conform to the user’s calibrationprocedures to ISO 9000.

Its exclusive redundancy of operations with PASCAL calibrators, the Scandura’s multi-function calibrator, remains unique, allowing a real integration between lab and fi eld calibration under identical quality procedures and calibration formats.

For complete specifi cations, please refer to data sheet CT 92.35.

Main features

■ 19" modular construction for table operation ■ Aluminium structure with painted steel plates on sides, top

and rear; front panels are made of anodised aluminium with engraved mimics

■ Digital measurement and simulation/generation of: pressure, vacuum, voltage, current, frequency, resistance/RTDs, thermocouples, switch status test

Typical dimensions

Width 553 mmDepth 500 mmHeight 766.5 mm

Page 8: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

8

Model CBM-SC3000Modular laboratory test systems

The CBM-SC3000 is a modular calibration solution for industrial instrumentation to suit any user requirement by means of diff erent modules designed for pressure, vacuum, temperature, electrical signals, auxiliary supplies, etc.

Each module is independent and enables the measurement, generation, distribution and control of diff erent variables.

Their combination allows to build up a customised calibration solution, opened for expansion whenever needed.

Main features

■ Bench worktable complete with holder console in two basic confi gurations, straight and corner version, with or without holder console

■ 19" modular construction for table operation ■ Full range of accessories available for easy operation

The CBM-SC3000 is available as bench worktable complete with holder console mounted across the rear of the worktable, to allow a total use of the working area.

Holder console is available for housing the modules up to 6 units.

For complete specifi cations, please refer to data sheet CT 92.36.

Precision pressure indicatorModel CPG2500see data sheet CT 25.02

AC resistance thermometry bridgeModel CTR6500see data sheet CT 60.40

Dead-weight testerModel CPB5800see data sheet CT 31.11

Temperature dry-well calibratorModel CTD9300see data sheet CT 41.38

Page 9: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

9

System description

Modular modules

Pneumatic utilities

DC supply electrical utilities

Main power supply and AC power sockets The AC power sockets module has been designed to accommodate the single-phase power supply mains switch of the bench complete with a diff erential earth leakage relay and to distribute a single-phase AC power supply to theinstruments.

The pneumatic module model is designed to generate pressure/vacuum signals for calibration and testing instruments.

It combines a manual pressure and vacuum generator, regulated air pressure outputs from external source with 3 preset pressure steps and an electric vacuum pump.

One of the modules is also equipped with two plug-in connections for each pressure output complete with built-in shut-off valves.

The variable DC power supply module is a confi gurable module according to with customer specifi cation and application. Various solutions can be off ered, from 1 to 2, 3 or more output channels, with fl exible output voltage/current ratings combination.

Page 10: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

10

Electrical and electronic

Temperature and electrics

Multifunction pressure / temperature electrical signal

This module is designed for measuring reference signals from thermocouples to test and calibrate temperature sensors and instruments. The module includes high-accuracy reference instrument, the 8-channel multiplexer provides for the scanning of up to 7 sensors to be tested, terminal board and power switch with lamp.

This module is designed for measuring reference signals from resistance thermometers to test and calibrate temperature sensors and instruments.The module includes a high-accuracy reference instrument, the 8-channel multiplexer provides for the scanning of up to 7 sensors to be tested,terminal board and power switch with lamp.

Scandura’s multi-function, multi-variable calibrator allows a real integration between lab and fi eld calibration under identical quality procedures and calibration formats. The user interface is represented bya wide LC display with touchscreen through which it is possible to set up the instrument in total.

The confi guration procedure is very simple. The touchscreen can also be used with hand gloves and in case of dirt you can easily clean it witha cloth or a sponge and lock it to avoid unintentional pressing of keys during the measurement process.

A variety of measuring equipment can be included in the test bench to suit thecustomer needs and requests such as:

■ Digital multimeters ■ Function generators ■ Oscilloscopes ■ LCR meters etc…

The selection of the suitable instrument for the application, will be made accordingly to the customer specifi cation and it will be integrated into the calibration systems.

Page 11: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

11

Assistance from the very beginning

WIKA / Scandura is your competent partner through all phases of the project: starting with planning the basic and detail engineering through the bench construction to the after-sales assistance.

Perfect logistics

Whether wooden cases or pallets, container shipment or sea-freight packaging, we will meet your delivery expectations. Our efficient distribution system is supported by both our subsidiaries and representative offices around the world. So you can be sure that the delivery will always arrive at the agreed time and at the agreed place.

Technical inspection

We offer our customers the possibility for acceptance tests and training on benches to be performed in our facilities prior to dispatch. You can therefore also count on the fact that all instruments will arrive at the installation site in perfect condition.

Extensive documentation

Specifically for your bench, we will prepare a complete book with dimensional drawings, data sheets, operating instructions and certificates in several languages, in digital and printed form.

Service in detail

Service in detail

Page 12: BR Calibration Systems en-co - wika.it · PDF fileCalibration of temperature instruments by comparison with ... temperature, electrical signals, ... Precision pressure indicator Model

WIKA Italia Srl & C. SasVia G. Marconi, 8 - 20010 Arese (MI)Tel. 02-93861.1 - Fax. 02-93861.74E-Mail: [email protected] - www.wika.it

11/2015 - GB