Top Banner
An IDEX Water & Wastewater Business pulsafeeder.com Boiler Boiler Programmable Boiler Controller
8

Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

Apr 06, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

An IDEX Water & Wastewater Business

pulsafeeder.com

BoilerBoilerProgrammable Boiler Controller

Page 2: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

ControllerSpecifications • Enclosure:NEMA4X/IP65• Dimensions:243.3x185x132 mm(9.58x7.25x5.20in)• PowerSupply:100-240VAC ±10%5A,50/60hz• ControlOutput: Prewiredrelay-5Amax; Drycontact-1Aperrelay• Display:LCD

Pulsafeeder Expertise Technology is the key to delivering responsible products to themarkets that we serve. Leading theway in the development ofmeteringtechnologies,Pulsafeedercontinuestosetthestandardforaccuracy,reliabilityandsafety.InnovationisanotherhallmarkofPulsafeeder.Helpingcustomersfindanewapproachtoanoldproblemiswhatwedobest.

MicroVision Boiler ControllerTheMicroVisionBoilerControllerdeliverscomprehensiveboilerwatercontrolwith‘plug&play’simplicity,atanoutstandingvalue.This latestaddition to theMicroVision familyof controllersisconfiguredspecifically forboilerwatercontrol,andutilizes intuitivesoftwarewhichprovidessimpleset-up,whileprovidingstateoftheartmaintenanceofthewaterinyourboiler.Featuresofthisdeviceincludeareliabletemperaturecompensatedconductivityprobe,5outputrelayswithselectabletimers,scalable4-20mAoutputtoreportconductivity,hall-effectandpulsewatermeterinputs,digitaldrumlevelsandaboilerinterlockinput.

CM

Standard SensorSpecifications• Max.Temp:200°C(392°F)• Max.Pressure:17Bar(250 psi)• SaturatedSteamMax.:14.4 Bar(210psi)• ConductivityRange:0to 20,000µS/cm• CellConstantandTC:1.0PT- 1000RTD• WettedMaterials:316SSandPEEK

Typical Applications • ComfortHeatProcess• IndustrialBoilers

Input and Output Functionality

System Outputs Blowdown Timer 1 Timer 2 Timer 3 Alarm/Timer 4Output Type Relay 1 Relay 2 Relay 3 Relay 4 Dry Contact

Limit X X X X28 Day X X X XPulse X X X X

Percent X X X XCycle X X X X

System Alarm X

Programmable Inputs Input 1 Input 2 Input 3 Input 4 Input 5Drum Level X X X X

Dry Contact Water meter X X X X XHall effect XInterlock X

Page 3: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

LED Display Up/Down Buttons

Blowdown

Timer 1Timer 2Timer 3

Liquid Tite forSensor Installation

On/Off Switch

Soft Keys

Mounting Holes

Clear Hinged Cover

Alarm Lights

Conduit or Pigtails

Boiler Controller Technology Pulsafeeder’slineofBoilerControllersaredesignedforsimplicityandreliability.Offeringaffordable,highperformanceBoilerControllersthatareeasytospecifyandeasytouse.PulsafeederBoilerControllersofferversatilesolutionstoyourfluidcontrolproblems.Withselectablesamplingmodes,poweredrelays,selectable timers,and inputs tofityourneeds.Pulsafeeder’sMicroVisionBoilercontroller increases energy efficiency, reduces water consumption, reduces manpower andoptimizeschemicalutilization.

Page 4: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

Features & Benefits

Simple Programming• Factorypresettooperateintimedsamplemoderightoutof thebox• Intuitivemenusmakeprogramalterationseasyand understandable

Easy Installation and Easy to Use• Pre-wiredandconduitconnectionsoptionsmakeeasy installation• Largegraphicaldisplaywithstatusscreenforinstantaccessto systeminformation• LEDfunctionindicators• Touchpadprogramkeysprovideclearandprecisesystem information

Reliable Conductivity Probe• Standardconductivityprobeisruggedandreliable• Temperaturecompensatedforaccuratereadingsfrom 0-20,000µS

Selectable Sampling Modes• Continuous• TimedSample• Sample&Hold

5 Output Relays• 1poweredrelayformotorizedballvalvesorsolenoid blowdownvalves• 3poweredrelaysforchemicalmeteringpumps• 1drycontactrelayforremotealarm

Page 5: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

Features & Benefits Features & Benefits

Selectable Timers• Pulse• Limit• Percent• 28day• Cycle

5 Digital Inputs• 5digitalinputstotal• Drumlevel• Drycontactwatermeter• Halleffect• Boilerinterlock

4-20mA Output• Isolated• Scalable

MVBX _ _ _ _ _ _ _ - XXXPRODUCT MVBX = MicroVision Boiler Controller DESIGNATORPosition 1 thru 4

REVIEW AND P = Prewired with pigtails (115 VAC only)WIRING C = Conduit connections (115V or 230V)Position 5

ENCLOSURE H = Heavy Duty EnclosureOPTIONSPosition 6

SYSTEM X = NoneOPTIONS A = 1/2" Solenoid valve, one 1" orifice union w/4 plates (Timed Sample) 100 PSI MAX.ASSEMBLED B = 1/2" Motorized ball valve one 1/2" flow throttling valve (Timed Sample) 250 PSI MAX

C = 1/2" Motorized ball valve one 1" orifice union w/4 plates (Timed Sample) 250 PSI MAXD = 3/4" Motorized ball valve, one 3/4" throtting valve, one 1/2" throttling valve (Continous Sample) 250 PSI MAXE = 3/4" Motorized ball valve, two 1" orifice union w/4 plates (Continous Sample) 250 PSI MAXF = High Pressure Flow Assembly (250 PSI) for cooling tower appliications

SENSOR X = No Sensor ProvidedOPTIONS S = Contact Electrode, 250 PSI Max (210 PSI for steam) 392° F MaxPosition 8

CABLE 000 = No Cable SuppliedLENGTH 010 = 10 Feet of sensor cablePosition 9 thru 11 025 = 25 Feet of sensor cable

050 = 50 Feet of sensor cable075 = 75 Feet of sensor cable100 = 100 Feet of sensor cable150 = 150 Feet of sensor cable

SUFFIX CODES XXX = Standard UnitPosition 12 thru 14

MicroVision Boiler Selection Guide

Position 7

Heavy Duty Enclosure• NEMA4Xrated• EasyInstallation

Page 6: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

System Options

Flow Assembly • HighPressureFlowAssemblyused forcoolingtowerapplications• 250psimax

Timed SampleOptionalValvesavailable• 1/2”SolenoidValve (1)1”OrificeUnionwith4plates• 1/2”MotorizedBallValve (1)1/2”flowthrottlingvalve• 1/2”MotorizedBallValve (1)1”OrificeUnionwith4plates

Continuous SampleOptionalValvesavailable• 3/4”MotorizedBallValve, (1)3/4”throttlingvalve, (1)1/2”throttlingvalve• 3/4”MotorizedBallValve (2)1”OrificeUnionwith4plates

Page 7: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

OptionalAlarmOutput

BoilerBoiler

BlowdownTimer 1Timer 2Timer 3

Union & Orifice Platemay be used in place of Throttling Valve

OptionalAlarmOutput

Union & Orifice Platemay be used in place of Throttling Valve

BoilerBoiler

BlowdownTimer 1Timer 2Timer 3

MicroVision Boiler Typical InstallationTypicalInstallationIncludes:• BallValve• ThrottlingValve• OrificeUnionandPlates• CrossAllAvailablefromPulsafeeder!

Continuous Sample

Timed Sample

Page 8: Boiler - Pulsa · Boiler Controller Technology Pulsafeeder’s line of Boiler Controllers are designed for simplicity and reliability. Offering affordable, high performance Boiler

pulsafeeder.com

27101 Airport RdPunta Gorda, FL 33982Phone: ++1(941) 575-3800Fax: ++1 (941) 575-4085 An ISO 9001 and ISO 14001 Certified Company

pulsafeeder.com

An IDEX Water & Wastewater Business

Parts & Accessories

Flow Control Valves - Boiler ApplicationsFlow control valves maintain sufficient back pressure in boilerblowdownlinesinordertopreventflashingandtoensureadequateblowdownrates.Theorificeunionincludesfourplates,1/16”,1/8”,1/4”anda5/16”.Flowcontrol valves includean indexedpositionindicator.

Valve Packages - System OptionsMaterialsofconstruction:SolenoidValvesarebronzebodywithstainlesssteelpilotandvalves;MotorizedBallValvesarecarbonsteelbodywith316stainlesssteelballandstem;ThrottlingValvesarecarbonsteelbodyandvalve;andOrificeUnionsarecarbonsteelunionwithstainlesssteelplates.

Contacting Head Water Meters Multi-Jet Meters3/4in.to2in.,aredesignedforuseinconjunctionwithapulsetimertoproportionally controlpumps, valvesetc.TheMulti-Jet chamberofthewatermeterassuresaccuracyoverawiderangeofflowswithlowheadloss.

Contact your local Pulsafeeder Distributor or Pulsafeeder Technical

Services at 800-333-6677

MVB001 H11

ASample Cooler providesasafemethodofwithdrawingandcoolingboilerprocesswater for analysis. Our 304SS coolersare easy to install, and handle samplepressuresto2500PSI.

PULSAtron Series Electronic Metering PumpsThe PULSAtron Series A PLUS and E PLUS electronic meteringpumpscanbeusedwiththeMicroVisionSeriescontrollerfortimerbasedchemicalmetering.