Top Banner
BioHPLC columns Tim Rice Biocolumn Technical Specialist
34

BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Jul 06, 2018

Download

Documents

hanhi
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

BioHPLC columns

Tim Rice

Biocolumn Technical Specialist

Page 2: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Typical Application Areas

Size Exclusion: Aggregation Analysis

Reversed Phase:

Separation of light and heavy chains

Ion Exchange: Charge Isoform Analysis

Peptide Mapping:

Post-translational modifications

AU

-0.005

0.000

0.005

0.010

0.015

0.020

0.025

0.030

0.035

Minutes

1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00

Dimer

Monomer

2

Page 3: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Size Exclusion

BioHPLC Columns

Page 4: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

NEW Size Exclusion Columns

• 5 m Particle

• 100Å, 150Å, 300Å, 500Å, 1000Å,

2000Å pore sizes

• High stability and long lifetime

• Great reproducibility

• Unique, 3 m particle

• 100Å, 150Å, 300Å pore sizes

• Highest resolution

• Highest efficiency

• Faster SEC separations

Page 5: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Smaller Particles for Higher Resolution

5

Min 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Agilent Bio SEC-3, 300Å,

7.8x300mm

Agilent Bio SEC-5, 300Å,

7.8x300mm

Column Pressure

Bio SEC-3

(7.8x300mm) 1350 psi

Bio SEC-5 (7.8x300mm)

650 psi

Peak Protein SEC-3, 300Å

(7.8x300mm)

SEC-5, 300Å

(7.8x300mm)

1 Thyroglobulin 2460 1120

2 BSA Dimer 5100 2720

3 BSA 13090 6590

4 Ribonuclease A 22000 11160

5 Uracil 38500 27860

Technology: Small Particle SEC Columns

Results: Higher Resolution SEC Separations

Page 6: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Use Higher Resolution to Achieve Faster

Separations

6

Column: Agilent Bio SEC-3, 7.8 x150mm Sample: mAb (2mg/ml)

Injection: 5ul

Flow rate: 1.0, 1.5 and 2ml/min (56 bar , 75 bar, 105 bar)

Eluent: 150mM sodium phosphate + 100mM Na-sulfate

Detection: 220nm

4 Minutes

monomer

dimer

2.0ml/min 1.5ml/min 1.0 ml/min

Increase flow rate and use a shorter column for

faster separations.

Technology:

Small Particle SEC Columns

Results:

Faster SEC separations

Page 7: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Mechanism of SEC Separation – Pore Size

Determines Linear Separation Range

Page 7

FLOW

Page 8: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Peptides Proteins Globular

proteins

Column Choice: Resolving Ranges

100D 1kD 10kD 100kD 1,000kD 10,000kD

Agilent Bio SEC 100Å

Agilent Bio SEC 150Å

Agilent Bio SEC 300Å

ProSEC 300S

Zorbax GF-250

Thyr

oglo

bulin

IgG

Ova

lbum

in

BS

A

Myo

glo

bin

Zorbax GF-450

Agilent Bio SEC 500Å

Agilent Bio SEC 1000Å

Agilent Bio SEC 2000Å

Insu

lin

Page 9: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Ion Exchange

BioHPLC Columns

Page 10: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

NEW Ion Exchange Columns

• Non-porous PS/DVB particles

(polystyrene divinylbenzene)

• Uniform polymeric coating with SCX,

WCX, SAX, WAX layers, designed for

protein and peptide separations

• Available in 10 µm, 5 µm, 3 µm, 1.7 µm

particle sizes

• High surface area

• High capacity

Page 11: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Agilent Bio IEX Columns Comparing Separations on Each Particle Size

Min

0 2 4 6 8 10 12 14 16 18 20 22

1.7 m

3 m

5 m

10 m

Column: Bio WCX-NP, 4.6x50mm

Buffer A: 20 mM PBS

Buffer B: A+1.0 M NaCl

Gradient: 0-100%B (20 min)

Flow rate: 1.0 mL/min for NP10, NP5, NP3

0.75 mL/min for NP1.7

Sample

1) Ribonuclease A

2) Cytochrome C

3) Lysozyme

Concentration: 1.0 mg/mL

Detector: 280 nm

Average N ~80,000 for WCX-NP1.7

Peak N

Peak N

Page 12: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Ion Exchange Chromatography Charge Isoform Analysis of Monoclonal Antibodies

12

AU

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

Minutes

0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 34.00

Column: Agilent Bio MAb, NP5, 4.6mm x 250mm

Buffer A: 10 mM Sodium Phosphate, pH 7.50

Buffer B: A + 100 mM NaCl, pH 7.50

Gradient: 15-95% B in 60 min

Flow rate: 0.8 mL/min.

Sample: 5 L, 5 mg/mL, mAb

(Acidic Isoforms)

weakly bound

(Basic Isoforms)

Strongly bound

Page 13: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Min 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

A

B

C

D

E

Optimization of method conditions for the isoform characterization of a

monoclonal antibody. Changes in the buffer conditions, pH and gradient

conditions sharpen peaks and increase resolution of acidic and basic isoforms.

Ion Exchange Chromatography Charge Isoform Analysis of Monoclonal Antibodies

Columns: Agilent Bio MAb, NP10, 4.6x250 mm

Mobile phase: A, 10 mM phosphate, pH 7.5

B, A + 0.1M NaCl

Gradient: A) 15-75%B in 30 min

B) 15-65%B in 30 min

C) 15-55%B in 30 min

D) 15-47.5%B in 30 min

E) 15-40%B in 30 min

Flow rate: 0.8 mL/min

Sample: Monoclonal Antibody

Injection: 10 L (1.5 mg/mL)

Temperature: 25 oC

Detection: UV 214 nm

Page 14: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Agilent Bio WCX: pH 7.0 – 5.8

14

Increased resolution

of early peaks

An increase in pH reduced the retention time.

An increase in pH increased resolution of earlier peaks (circled).

Page 15: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Reverse Phase

BioHPLC Columns

Page 16: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Zorbax Stablebond for

Reverse Phase Separations of Proteins

300 A pore size

available in C-3, C-8, C-18, and CN

non-endcapped

particle sizes: 3.5, 5, and 7

16

O

R RSi

OH

Si

O

SiR R R

OOH

R

R1 R1 R1

Page 17: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

NEW! Zorbax 300 SB RRHD for Proteins and Peptides!

• Stablebond 300 silica

• C-18, C-8, C-3, HILIC and diphenyl bonded phase

• 1.8 um particle size

• 1200 Bar pressure limit for uHPLC

• 2.1 x 50 mm and 2.1 x 100 mm

Page 18: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

UHPLC Columns Increase Resolution and Increase Speed

Column

Length (mm)

Resolving

Power

N(5 µm)

Resolving

Power

N(3.5 µm)

Resolving

Power

N(1.8µm)

150 12,500 21,000 32,500

100 8,500 14,000 24,000

75 6000 10,500 17,000

50 4,200 7,000 12,000

30 N.A. 4,200 6,500

15 N.A. 2,100 2,500

Analysis Time

Peak Volume

Analysis

Time*

-33%

-50%

-67%

-80%

-90%

Solvent Usage

* Reduction in analysis time compared to 150 mm column

Page 19: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

19

Column: Zorbax 1.8um 300SB-C18 RRHD, 2.1x100mm

A : .1% TFA in water, B: .085% TFA in ACN

Gradient: 20%B 1min, 2-45%B 8.8min, 45-95%B .2min, 95%B 2min, 98-2%B .2min, 20%B 1.8min

Flow rate: .5 ml/min, Temp: 50C, Pressure: ~640bar

Sample: Protein digest, 5ul inj vol, 1 mg/ml

300SB-C18 RRHD Protein Digest TB# 5990-7989EN

Page 20: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Fast Separation of Reduced and Alkylated MAb

20

min 1 2 3 4 5

mAU

0

20

40

60

80

100

120

0.4

54

0

.50

1

0.5

69

0.7

66

3.8

97

4.0

10

Light chain

Heavy chain 1 Heavy chain 2

Columns: ZORBAX RRHD 300SB-C3, 2.1 x 100 mm, 1.8 µm

Sample: Reduced MAb (IgG1) (1.0 mg/mL)- BioCreative IgG1

Sample injection: 2 µL

Mobile phase A: 0.1% TFA in water

Mobile phase B: 80% n-propyl alcohol, 10% ACN, 9.9% water and 0.1% TFA

Temperature: 74 °C

Flow rate: 0.5 mL/min

Detection: UV, 280

Conditions optimized for the ZORBAX RRHD 300SB-C3 Column

CHO Cell Derived MAb

Time

(min)

%B

0 1

2 20

5 50

6 90

6.1 1

TB# 5990-9667EN

Page 21: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Comparison C3 and Diphenyl Phases

21

min 1 1.2 1.4 1.6 1.8 2 2.2 2.4

mAU

2

4

6

8

10

12

1.3

37

1.5

87

1.6

66

1.7

54

1.8

11

min 1 1.2 1.4 1.6 1.8 2 2.2 2.4

mAU

2

4

6

8

10

12 1.3

45

1.5

64

1.6

46

1.7

87

1.8

46

ZORBAX RRHD 300SB-C3, 1.8 µm

ZORBAX RRHD 300-Diphenyl, 1.8 µm

Ribonuclease A, Cytochrome C and Lysozyme (3 mg/mL)

Time

(min)

%B

0 10

2.5 70

Arrows indicate better separation

resolution of ZORBAX RRHD

300-Diphenyl

TB# 5990-9668EN

Page 22: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

NEW! AdvanceBio Peptide Mapping Column for

HPLC and UHPLC:

• 2.7um Superficially Porous

• 120A pore size

• 600 bar pressure limit

• 2um frit to reduce clogging

22

Save Time: 2 to 3 times faster than fully porous particles

Increased Flexibility: Highly compatible with TFA and formic acid mobile

phases for efficient LC/MS analysis

Greater analytical confidence: Each batch is tested with a rigorous peptide

mix to ensure suitability and reproducibility

Page 23: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Decrease the diffusion time for macromolecules and limit the diffusion path!

The particle has a solid core (1.7um) and porous outer layer with a 0.5um diffusion path

Reduces secondary interactions & enables selective separation for a wide range of

peptides.

.

Superficially Porous Particle Technology

Page 24: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Chromatographic Comparison BSA tryptic digest

24

min 0 2.5 5 7.5 10 12.5 15 17.5 20

mAU

0

10

20

30

40

50

60

70

min 0 2 4 6 8 10 12

mAU

0

10

20

30

40

2.7um AdvanceBio Peptide Mapping, 2.1 x 150mm, gradient adjusted for length

104 peaks

319 Bar

Vendor B, 1.7um, C18, 2.1 x 100mm, gradient adjusted for length

97 peaks

476 Bar

Greater Rs, increased sensitivity

Less Rs, decreased sensitivity

Conditions: water/ACN (TFA), 40C, .3 mL/min

Page 25: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

25

Peptide Mapping for LC/MS

min 0 5 10 15 20 25 30

mAU

0

50

100

150

200

250

300

Agilent LC/MS

100% sequence coverage

Digested EPO (recombinant humanized) separated on a 2.1 x 250mm AdvanceBio Peptide Mapping Column

Mobile phase: A-water (0.1%FA), B- ACN (0.08%FA), temp: 55C, Flow: 0.5mL/min

Excellent separation capability for generating peptide maps of highly desired proteins, i.e.,

glycopeptide mapping during fast analysis times

Provides compatibility with TFA and Formic acid mobile phases for LC/MS analyses

Pressure maintained below 600bar for 250mm column length

Digested EPO Protein

Glycopeptide mapping

TB# 5991-1813EN

Page 26: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Poroshell 300

300 A pore size

Stablebond chemistry

available in C-3, C-8,C-18, and C-18 Extend

5 um particle size

Porous

Shell

SOLID CORE

5 m

Page 27: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

High Flow Rates with 2.1 mm ID Poroshell for High

Resolution and Fast Separations

1

2

34

5

67

8

0 0.5 1.0

Time (min)

Columns: Poroshell 300SB-C18

2.1 x 75 mm, 5 m

MP: A: 0.1% TFA

B: 0.07% TFA in ACN

Gradient: 5 – 100% B in 1.0 min.

Flow Rate: 3.0 mL/min.

Temperature: 70

C

Pressure: 250 bar

Detection: UV 215 nm

Sample:

1. Angiotensin II

2. Neurotensin

3. Rnase

4. Insulin

5. Lysozyme

6. Myoglobin

7.Carbonic

Anhydrase

8.Ovalbumin

TB# 5989-9899EN

Page 28: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

Reversed Phase

Heavy and light chain analytical characterization

Use of 1200 LC, Poroshell 300SB

columns and UV detection to

characterize antibodies

28

TB# 5989-0604EN

Page 29: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

More Poroshell Bonded Phases Provide Selectivity

Options to Enhance Resolution:

min0 0.5 1 1.5 2 2.5

mAU

0

100

200

300

400

DAD1 A, Sig=215,16 Ref=360,100 (05080223.D)

Poroshell SB-C18, 2.1 x 75 mm

1

2 3 4

5, 6

7

8

9 0.9

76

1.0

77

1.2

89

1.3

95

1.4

63

1.5

23

1.7

41

1.8

60

3.0

12

min0 0.5 1 1.5 2 2.5

mAU

0

100

200

300

400

DAD1 A, Sig=215,16 Ref=360,100 (05080225.D)

51

23

4

6

7

8

9

Poroshell SB-C3, 2.1 x 75 mm

0.9

01

1.0

36

1.2

64

1.3

54 1.4

30

1.4

49

1.4

97

1.7

39

1.8

37

Column: Agilent Poroshell (2.1 x 75 mm); Temp.: 70 0C; Flow: 0.5 mL/min; Det: UV 215 nm

Mobile Phase: A= 0.1% TFA/H2O, B= 0.07% TFA/ACN; Gradient: 5-100% B in 3.0 min

1.5

5

4 6

7

1.5

5

4 6

7

1.5

4

5, 6

7

1.5

4

5, 6

7

Samples:

1. Angiotensin II

2. Neurotensin

3. RNase A

4. Insulin B Chain

5. Insulin

6. Cytochrome C

7. Lysozyme

8. Myoglobin

9. Carbonic

Anhydrase

Poroshell 300SB-C18

2.1 x 75 mm

Poroshell 300SB-C3

2.1 x 75 mm

•Changing from SB-C18 to SB-C3, within the Poroshell family results in resolution of peaks 5 and 6, still in 3 min!

Page 30: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

PLRP-S

Polystyrene divinylbenzene bead

Available in 100, 300, 1000, and 4000A pore sizes

Particle sizes 3, 5, 8, 10, and higher

Various geometries from Capillary to preparative

pH 2-14 stable

Page 31: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

25-bp Ladder Double Stranded DNA Ladder

1

1 1

12% PAGE

25

25

50

25

25

50

50

100

100

100

100

50

1 1

1 1

time

HPLC

PLRP-S 100Å

PLRP-S 300Å

PLRP-S 1000Å

PLRP-S 4000Å

Column: PLRP-S 150x2.1mm ID

Eluent A: 100mM TEAA

Eluent B: 100mM TEAA, 50% ACN

Gradient: 12.5%-50%B in 150 mins

Flow Rate: 200µl/min

Pore Size Resolving Range

100Å 50-70 bp

300Å Up to 250-300 bp

1000Å Up to 400-450 bp

4000Å >500 bp

Page 32: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

In Summary

Agilent has many options for the analysis of bio-molecules and

will continue to develop new products to address this growing

market.

Page 33: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

NEED ASSISTANCE?

LC Column help desk

1-800-227-9770

• orders

• customer service

(option 1,1)

• technical support

• applications assistance

(option 3,3,2)

33

[email protected]

Page 34: BioHPLC columns - Agilent · Tim Rice Biocolumn Technical Specialist . Typical Application Areas Size Exclusion: Aggregation Analysis Reversed Phase: Separation of light and ...

BioHPLC Columns on the Agilent Website

To learn more and order online visit

www.agilent.com/chem/BioHPLC