Top Banner
Bio -1000F Test Reference Exposure Time x2 Exposure Time x2 Exposure Time x4 Exposure Time x4 Following electrophoresis (voltage: 50 V), the images were caught by Bio-1000F with different exposure times. 5 μl of Bio100 TM Mass DNA Ladder (Protech Technology Enterprise Co., Ltd.) was loaded into line 1 (2 0 ). Twofold serial dilutions of the ladder were prepared in 1x DNA loading dye and loaded into lanes 2 to11 (2 -1 to 2 -10 ). 5 μl of Bio100 TM Mass DNA Ladder (Protech Technology Enterprise Co., Ltd.) was loaded into line 1 (2 0 ) of 2% TAE agarose gel. Twofold serial dilutions of the ladder were prepared in 1x DNA loading dye and loaded into lanes 2 to11 (2 -1 to 2 -10 ). The images were caught by Bio-1000F with different exposure times. Following electrophoresis (voltage: 50V), the gel were immersed into 1x TAE buffer with 1/20,000 Diamond™ Nucleic Acid Dye for 30 minutes at 30°C . Protocol Result Manufacturer : Promega Stain : Diamond™ Nucleic Acid Dye DNA Electrophoreis Post-Staining Precast Gel 3 μl Diamond™ Nucleic Acid Dye in 60 ml 2% TAE agarose gel. 2 3 1 1 3 2
2

Bio -1000F Test Reference - Microtekww1.microtek.com.tw/...Bio-1000F_Stain_Ref_Diamond.pdf · Bio -1000F Test Reference Exposure Time x2 Exposure Time x2 Exposure Time x4 Exposure

Jul 12, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Bio -1000F Test Reference - Microtekww1.microtek.com.tw/...Bio-1000F_Stain_Ref_Diamond.pdf · Bio -1000F Test Reference Exposure Time x2 Exposure Time x2 Exposure Time x4 Exposure

Bio -1000F Test Reference

Exposure

Time

x2Exposure

Time

x2

Exposure

Time

x4Exposure

Time

x4

Following electrophoresis (voltage: 50 V), the images were caught by Bio-1000F with different exposure times.

5 µl of Bio100TM Mass DNA Ladder (Protech Technology Enterprise Co., Ltd.) was loaded into line 1 (20). Twofold serial dilutions of the ladder were prepared in 1x DNA loading dye and loaded into lanes 2 to11 (2-1 to 2-10).

5 µl of Bio100TM Mass DNA Ladder (Protech Technology Enterprise Co., Ltd.) was loaded into line 1 (20) of 2% TAE agarose gel. Twofold serial dilutions of the ladder were prepared in 1x DNA loading dye and loaded into lanes 2 to11 (2-1 to 2-10).

The images were caught by Bio-1000F with different exposure times.

Following electrophoresis (voltage: 50V), the gel were immersed into 1x TAE buffer with 1/20,000 Diamond™ Nucleic Acid Dye for 30 minutes at 30°C .

Protocol

Result

Manufacturer : PromegaStain : Diamond™ Nucleic Acid Dye

DNA ElectrophoreisPost-StainingPrecast Gel

3 µl Diamond™ Nucleic Acid Dyein 60 ml 2% TAE agarose gel.

2

3

1 1

3

2

Page 2: Bio -1000F Test Reference - Microtekww1.microtek.com.tw/...Bio-1000F_Stain_Ref_Diamond.pdf · Bio -1000F Test Reference Exposure Time x2 Exposure Time x2 Exposure Time x4 Exposure

Dilution

Times

104

Dilution

Times

105

Dilution

Times

106

Result

Decreasing the concentration of Diamond™ Nucleic Acid Dye in precast gels can solve the problem of

smeared and discrepant DNA migration.

Bio -1000F Test Reference

Improvements for Nucleic Acid Gel Stain

Dilution

Times

5x106

( Exposure time: x4 ) ( Exposure time: x4 )