S.No. Description of Part-I and Part- II Total Cost as per quoted amount (In words) Total Cost as quoted amount (In figures) 1 Total amount of Part-I 2 Total amount of Part-II Total Amount of Part-I & II Package-2: Arand-Lakhna Summary Sheet of Bill of Quantities Part-I & Part-II Name of Work: Construction of Roadbed, Major & Minor bridges, Track Linking (excluding supply of rails, ordinary track sleepers and thick web switches), Outdoor Signaling and Electrical (General) works in connection with Doubling of LAKHANA(Ex) – ARAND(in) section(68.936 Kms) part of RAIPUR-TITLAGARH Doubling in SAMBALPUR Division of East Cost Railway in the states of ODISHA & CHATTISGARH, India.”
110
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Bill of Quantities Pkg-2

S.No. Description of Part-I and Part-II Total Cost as per quoted amount (In words) Total Cost as quoted amount (In

figures)

1 Total amount of Part-I

2 Total amount of Part-II

Total Amount of Part-I & II

Package-2: Arand-Lakhna

Summary Sheet of Bill of Quantities Part-I & Part-II

Name of Work: Construction of Roadbed, Major & Minor bridges, Track Linking (excluding supply of rails, ordinary track sleepers and thick web switches), Outdoor Signaling and Electrical (General) works in connection with Doubling of LAKHANA(Ex) – ARAND(in) section(68.936 Kms) part of RAIPUR-TITLAGARH Doubling in SAMBALPUR Division of East Cost Railway in the states of ODISHA & CHATTISGARH, India.”

Page 2: Bill of Quantities Pkg-2

Sr. No

Description of Schedule

In Figures In Words1 2 3 41 Earthwork in Formation

2ABridge work (Other than Steel works)

2BBridge work (Steel items Involving Fabrication and Erection)

2C Bridge work (Supply of Steel items )3 Ballast Supply

4 AP.Way Supply (Other than steel items)

4 BP.Way Supply (Steel Items)

5 APermanent Way Linking: Installation Works

5 BPermanent Way Linking: Supply and Installation Works

6 Buildings

7BPlatform, Passenger Amenities and Miscellaneous Works : Steel items

8 Supply of Cement10 S &T (Supply & Installation)

Total Amount of Part-I (Carried forward to summary sheet of Bill of Quantities Part-I & II)

Package-2 : Arand - Lakhna

Summary Sheet of Bill of quantities , Part-I

Total cost in Rs.

Page 3: Bill of Quantities Pkg-2

1 2 31 Earthwork in Formation 20,754,029

2ABridge work (Other than Steel works) 9,061,272

2B Bridge work (Steel items Involving Fabrication and Erection) 6,776,575

4 AP.Way Supply (Other than steel items) 17,230,464

4 BP.Way Supply (Steel Items) 9,329,858

5 APermanent Way Linking: Installation Works 47,453,127

5 BPermanent Way Linking: Supply and Installation Works 1,817,926

6 Buildings 42,387,541

7APlatform, Passenger Amenities and Miscellaneous Works : Other than Steel items 113,608,095

7BPlatform, Passenger Amenities and Miscellaneous Works : Steel items 984,913

9 Site Facility 19,025,230

10 S &T (Supply & Installation) 33,869,358

11 General Electrical works 42,149,386

Total Amount 364,447,774

______ %age Above/Below / At par over estimated Rates (in figures and words

Total Amount of Part-II (Carried forward to summary sheet of Bill of Quantities, Part I & II (Amount in figures)TOTAL Amount of Part-II (Amount in words)

Package:2 Arand - Lakhna

NOTE: Tenderer should quote a single percentage for all schedules of Part II in the space provided above

Summary Sheet of Bill of quantities, Part-II

Sr. No. Description of Schedule Estimated cost in Rs.

Page 4: Bill of Quantities Pkg-2

1001 Earthwork in filling in formation including trolley refuges, etc using contractor's earth of approved quality procured from outsiderailway land including site clearances, setting out and demarcation, benching, initial compaction of subsoil after leveling the surfaceafter site clearance, spreading loose earth in 30 CM layers using grader up to extra width of 0.5 M beyond designed profile, compactionusing vibratory compactors so as to achieve minimum in situ dry density of 98% of MDD, top and side dressing and removal of extraearth from sides to provide final formation as per designed profile. The rate shall include cutting of trees with girth upto 60 CM ,making good the pockets and depressions left in soil during clearing and uprooting of jungle/trees at site and one round of heavy rollingof sub-soil there after. The rate shall not include cutting of trees of girth beyond 60 CM and compaction which shall be paid seperately.

307975 Cum

1002 Earthwork in cutting in formation, trolley refuges, side drains, yard drains, catch water drains, etc. including leading usable cut spoils upto 200 M and making formation in filling using the cut spoils, site clearances, setting out and demarcation, disposing off surplusunusable cut spoils as per directions of the engineer, and top and side dressing to provide final formation as per designed profile. Therate shall not include cutting of trees with girth above 60 CM and compaction, which shall be paid separately.

1002 a Soil excluding rock. 351448 Cum 1002 b Rock not requiring blasting. 75310 Cum 1002 c Rock requiring blasting. 50207 Cum 1002 d Rock requiring blasting, but blasting not permitted hence to be excavated by chiselling . 25103 Cum1003 Incremental rate for every Km or part thereof over item 1002 for leading cut spoils beyond 200 M for making formation in filing. 1732326 Cum Km

1004 Providing and laying blanketing materials of grading as per latest guidelines of RDSO in layers of 30 CM in loose state using graders andcompaction using vibratory compactors so as to achieve minimum in situ dry density of 98% of MDD, top and side dressing to providefinal formation as per designed profile. The rate shall not include compaction, which shall be paid separately. 658517 Cum

1006 Turfing with sods, 10 CM thick and 20 CM square closely laid, including dressing, repair to rain cuts and watering as required untilturfing is properly rooted. Payment to be released in two stages: (i) 50% on completion of turfing; and (ii) balance 50% after properrooting of the turf.

210227 Sqm

1009 Supply & Planting of trees in railway land of varieties such as Shisham, Neem, Pilkhan and other indigenous varieties suitable to the area in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings,

backfilling the trench, watering inlcuding cost of labour and materials as per direction of Engineer-in-charge and maintaining the plants for one year.

1. Payment for surviving trees after three months of plantation - 25%2. Payment for surviving trees after six months of plantation - 25%3. Payment for surviving trees after one year of plantation - 50%

3447 Each

Total for Bill No.1 (Carried forward to Summary of Part-I)

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.1 : EARTHWORK IN FORMATION

S.No. Description of Item Qty Unit Rate in Rs. Amount in Rs.

Page 5: Bill of Quantities Pkg-2

2003 Providing and laying cement concrete 1: 3: 6 in foundation and floor using well graded stone aggregate of 40 MM nominal size.703 Cum

2004 Providing and laying design mix control concrete M20/M25 in piers, retaining walls, wing walls, return walls, bottom/top plug ofwells and protection work etc. using well graded stone aggregate of 40 MM nominal size. 11695 Cum

2005 Providing and laying Design mix control concrete M25/M30/M35/M40 in RCC works of raft, pile cap, pier, abutment, well stening,RCC well kerb, well cap, pier cap, Jacketing, dirt wall, return wall, wing wall, fly wing wall, retaining wall, approach slab, foot pathslab, wearing course, ballast retainers, RCC railing, inspection platform, pedestal, boxes and other miscellaneous works using wellgraded stone aggregate of 20 MM nominal size.

12879 Cum

2006 Providing precast/cast-in-situ post tensioned PSC girders including diaphragms and deck slab with design mix control concreteM45/M50 including sheathing, anchorages, bearing plates, permanent wedges, positioning of strands in sheathing as per profile,stressing and distressing, grouting, launching precast girders in position, etc. Note:1. Rate excludes cost of HTS strands (their placement in sheathing, stressing and grouting), sheathing, anchorages, TMT bars andcement, which shall be paid separately under relevent items. 2. Payment for precast girders shall be released in two stages: (i) 75% on casting and stressing of girders; and (ii) 20% after launchingprecast girders in position and casting of deck slab; and (iii) balance 5% on completion in all respects.

1230 Cum

2012 Providing and laying dry stone backing behind abutments, wing walls, return walls, RCC boxes with stones not less than 15 CM in anydirection and not less than 15 KG (except smaller boulders required for filling voids) in weight. 6422 Cum

2013 Providing and laying backfill material behind boulder filling of abutments, wing walls, return walls consisting of granular materials ofGW, GP, SW groups as per IS 1498-1970 in required profile . 17236 Cum

2014 Providing and laying 300 MM thick dry stone pitching in flooring, exposed slopes, etc. with boulders of not less than 30 KG each inweight, hand packed with surface levelled off to the correct section with hammer dressing as necessary including filling the gaps withquarry spalls.

4938 Cum

2015 Providing IPN coating (developed by CBRI) on PSC girders, slabs and other structures as directed by the Engineers 4950 Sqm

2019 Boring and installing reinforced cement concrete cast-in-situ bored piles in M30/M35 design mix control concrete using well gradedstone aggregate of 20 MM including boring in all kinds of soil, boulders and gravels (length of pile for payment shall be measured up tothe bottom of pile cap. No payment shall be made for boring and concreting from ground level to bottom of pile cap level.)

2019a 1200 MM dia pile 1200 Meter

NS-2 Driving of Contractor’s unserviceable rail by hammering with the help of monkey hammer or by an other means in to soft or mediumhard strata with all Contractor’ tools and plants, equipments, labour, lead, lift ascent, descent etc complete as per approved drawingand as directed by the Engineer.Note : 1. The payment of Rail will be made for the finished length buried in the ground

267 Meter

Description of Item Qty

Total of Bill No 2A (Carried forward to Summary of Part-I)

Unit Rate Amount

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.2 : BRIDGESSchedule 2A Bridge work (other than steel items)

S.No.

Page 6: Bill of Quantities Pkg-2

2051 Supply of Pre-stressing cables of required size and configuration of low relaxation high tensile steel strands (class-II) confirming to IS:14268.The rate includes cost of sheathing, anchorages, placing of strands placing of the strands in HDPE sheething of required diameters and ofID specification as per IRS, as per profile, stressing & destressing and grouting complete as directed by Engineer.Note: The quantity of prestressing cables provided in permanent work excluding wastages shall only be measured for payment andpayment shall be made after the quantity is consumed in the relevant item.

40 MT

Amount in Rs

Total for Bill 2 B (Carried forward to Summary of Part-I)

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.2 : BRIDGESSchedule 2B Bridge work (Steel items Involving Fabrication and Erection )

S.No. Description of Item Quantity Unit Rates in Rs.

Page 7: Bill of Quantities Pkg-2

2061 Supplying TMT Fe-500 reinforcement steel conforming to IS:1786-1985 including decoiling, straightening, cutting, bending,placing in position, binding with 1MM dia GI binding wire. Note : Reinforcement, shall be measured in length for different diameters used in the works and then paid as per standardweights as per IS 1732. Wastages, overlaps, coupling, welded joints, space bars, chairs and binding wire shall not bemeasured and cost of these items shall be deemed to be included in the rates.

1675 MT

Description of Item Quantity

Total for Bill 2 C (Carried forward to Summary of Part-I)

Unit Rates in Rs Amount in Rs

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.2 : BRIDGESSchedule 2C Supply of Steel items

S.No.

Page 8: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rate in Rs.Amount

in Rs3001 Supply of machine-crushed stone ballast on cess as per RDSO specifications for track ballast: IRS-GE-1 of June, 2004

from outside railway limits stacked in specified quantities alongside the proposed alignment on either side of track, in yardsand at locations as per site requirement as directed by the Engineer. Note: a) Payment will be made on actual stack measurement for gross quantities without any deduction for voids in followingstages: (i) 95% on receipt at site, acceptance, measurement, account, proper storage and protection against loss, damageor deterioration; and (ii) balance 5% after training out.b) Wherever suficient Railway land is not available, contractor will have to arrange land for supply & stacking of Ballast at hisown cost for which nothing extra will be paid.c) The rate alo includes levelling, dressing of ground for stacking of ballast.

173,334 Cum

3002 Supply of machine-crushed stone ballast in depot as per RDSO specifications for track ballast: IRS-GE-1 of June,2004 from outside railway limits duly stacked. Note: a) Payment will be made on actual stack measurement for gross quantities without any deduction for voids in followingstages: (i) 95% on receipt at site, acceptance, measurement, account, proper storage and protection against loss, damageor deterioration; and (ii) balance 5% after training out.b) Wherever suficient Railway land is not available, contractor will have to arrange land for supply & stacking of Ballast at hisown cost for which nothing extra will be paid.c) The rate alo includes levelling, dressing of ground for stacking of ballast.

30,000 Cum

NOTE

BILL No.3 : BALLAST SUPPLY

Quantity under item 3001& 3002 may vary as per site conditions and variation clause is applicable on overall quantity of item 3001 & 3002 combined together.

Package-2 : Arand - Lakhna Bill of quantities , Part-I

Total for Bill No.3 (Carried forward to Summary of Part-I)

Page 9: Bill of Quantities Pkg-2

4003 Supply of Switch Expansion Joints with all fastenings and fixtures complete (excluding liners, ERC, fish plates, fish bolts and nuts)including angle iron for fixing on PSC sleepers and painting. "Rails will be issued free of cost by the Employer @ 2x13 M rail foreach SEJ set which comprises of two stock and two tongue rails".

4003 a For 60 KG as per RDSO Drawing No. T -4165/5478/5586/5748/6227/6263 46 Set

4003 b For 52 KG as per RDSO Drawing No.T-4160/603920 Set

NS-1 Supply of Special Prestressed Concrte Sleepers for B.G. (Monoblock Sleepers) for 1 in 12 Turnouts for B.G 60 Kg. (UIC) rail/52 kgrails to RDSO Drg. No. T-4218 Alt-5 (for general layout) and drawings there of with latest alterations if any. Specification : as perdrawing.

58 Set

NS-2 Supply of Special Prestressed Concrte Sleepers for B.G. (Monoblock Sleepers) for 1 in 8.5 Turnouts for B.G 60 Kg. (UIC) rail/52 kgrails to RDSO Drg. No. T-4865 Alt-5 (for general layout) and drawings there of with latest alterations if any. Specification : as perdrawing.

4 Set

NS-3 Supply of Special PSC Monoblock Sleepers (pre-tensioned type) for B.G. Turnouts for 1 in 8½ Derailing Switch as per RDSO Drg.No.-T-6068 to suite both 52/60 kg rails as per RDSO Design and IRS Specifications No. T-45-96 (2nd Edition) as amended fromtime to time.

9 Set

Payment Conditions for items of this Bill:1

a. Supplier's challan and manufacturer's challan.

b. Inspection certificate issued by Employer's/Engineer's nominated inspecting agency.

c. Comprehensive Insurance policy for the supply.

d. Quality Assurance documents.

e. Indemnity bond for entire cost of material supply.

2 The remaining 10 % payment shall be made after commissioning of the portion of the work or handing over of the material to the employer's / Railway's Representative, required for maintenance purposes.

Total for Bill No.4 A (Carried forward to Summary of Part-I)

Unit Rate in Rs Amount in Rs

90% payment shall be made on receipt, acceptance, accountable and taking into custody of complete materials including stacking of materials as per IRPWM and / or Railway guidelines issued by Railway from time to time at noinated locations. The invoices shall be accompanied by the following:

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.4 : PERMANENT WAY SUPPLYPart 4 A: P.WAY SUPPLY (Other than Steel Items)

S.No. Description of Item Quantity

Page 10: Bill of Quantities Pkg-2

4021 Supply of P.Way Components

4021 a ERC to RDSO Drg. No.T-3701 526275 Each

4021 b ERC "J" to RDSO Drg. No.T-4158 7270 Each4021 c Metal Liners to RDSO Drg No. T-3740 402225 EachNS-12 Supply of 52 KG 1 in 8½ 6400mm OR Switch conforming to RDSO's Drg. T-4866 with latest alteration, if any complete with all

parts as listed in the drawing excluding fish plates, fish bolts & nuts, Plate screws, GRSPs, Liner and ERCs.4 Set

NS-14 Supply of 52 KG 1 in 8½ Derailing Switch conforming to RDSO Drg No. 5836 with latest alteration, if any complete with all parts aslisted in the drawing excluding fish plates, fish bolts & nuts, Plate screws, GRSPs, Liner and ERCs.

9 Set

NS-7 Supply of 52 kg CMS Crossing for 1 in 8½ PSC Layout conforming to Drg No. T-4867 with latest alterations complete with C.I.Distance Block, Packing Pieces, MS Tapered Washers, Single Coil Spring washers, Check Blocks and bolts of different sizes andother fittings listed in the drawing excluding Fish Plates and Bolts.

4 Nos

NS-6 Supply of 60 kg CMS Crossing for 1 in 12 PSC Layout conforming to Drg. No.T-4220 with latest alterations complete with C.I.Distance Block, Packing Pieces, MS Tapered Washers, Single Coil Spring washers, Check Blocks and bolts of different sizes andother fittings listed in the drawing excluding Fish Plates and Bolts.

64 Nos

Payment Conditions for items of this Bill:1

a. Supplier's challan and manufacturer's challan.

c. Comprehensive Insurance policy for the supply.d. Quality Assurance documents.e. Indemnity bond for entire cost of material supply.

2 The remaining 10 % payment shall be made after commissioning of the portion of the work or handing over of the material to the employer's / Railway's Representative, required for maintenance purposes.

Quantity Unit Rates in Rs Amount in Rs

b. Inspection certificate issued by Employer's/Engineer's nominated inspecting agency.

90% payment shall be made on receipt, acceptance, accountable and taking into custody of complete materials and stacking as per IRPWM and/or Railway guidelines at nominated locations. The invoices shall be accompanied by the following:

Total for Bill No.4B (Carried forward to Summary of Part-I)

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.4 : PERMANENT WAY SUPPLYPart 4 B: P.WAY SUPPLY (Steel Items)

S.No. Description of Item

Page 11: Bill of Quantities Pkg-2

5006 Installation of BG track as per methodology specified in para 4.0 of Section 5: Specifications in the Bidding Documents or any othermethodology approved by the Employer in all locations e.g. straight, curves, bridges, level crossings, yards, etc including installation ofSEJ and glued joints including installation and dismantling of auxiliary track. 75121

Track Meter

5013 Flash butt welding of 60 KG, 52 KG rails and panels, as per manual for flash butt welding of rails 1996, in track or out side track, in depotor in mid section for making panels including removing and refixing the fittings, creating required gap by pulling the rails, handling ofrails. Ultrasonic testing of welded joints shall be paid separately. 10434 Each

NS-20 Loading/unloading of Clint’s P.Way material of all types to/from any type of Rly. Wagons, truck, trailor etc. 10120 MT

Description of Item Quantity

Total for Bill No.5A (Carried forward to Summary of Part-I)

Unit Rates in RS. Amount in Rs.

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.5 : PERMANENT WAY LINKINGSchedule 5A : Installation Work

S.No.

Page 12: Bill of Quantities Pkg-2

5041 Welding of rails by SKV thermit process in track under traffic block for conversion to SWR, LWR, CWR including finishing the joints usinggrinders. Ultrasonic testing of welded joints shall be paid separately.

5041 a 60 KG rail 1844 Each5041 b 52 KG rail 1308 Each

Description of Item Quantity

Total for Bill No.5B (Carried forward to Summary of Part-I)

Unit Rates in Rs. Amount in Rs.

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.5 : PERMANENT WAY LINKINGSchedule 5B : Supply and Installation works

S.No.

Page 13: Bill of Quantities Pkg-2

6004 Supplying and fixing pre-cast RCC platforms fencing as per Railway plan along with posts at various stations with RCC M-20 (20mmand down gauge broken aggregate) involving casting of members in the casting yard (including all shuttering, cutting, straightening,bending and binding of reinforcement), curing leading and erection to true line, level and plumb including fixing posts in cementmortar as per drawing and two coats of snowcern complete with all labour, cement, steel and other materials. The fencing posts willbe fixed in CC M-10. The rates are inclusive of all cement, steel etc complete.

5135 Meter

TOTAL FOR BILL No.6 (Carried forward to Summary of Part-I)

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.6 : BUILDINGS

S.No. Description of Item Quantity Unit Rates in Rs Amount in Rs

Page 14: Bill of Quantities Pkg-2

7041 Providing FOB, platform shelters, columns, beams, trusses and other steel components of miscellaneous works duly launched inposition with or without traffic block as directed by Engineer with contractors steel conforming to IS:2062-1999 including fabrication,assembly, erection, launching, riveting/welding, bolting, initial coats of zinc chromate priming conforming to relevant IS specificationand three subsequent coats of aluminium paint of approved quality conforming to IS:2339 after final erection on all surfacescomplete.

100 MT

Rates in Rs Amount in Rs

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL No.7: PLATFORM, PASSENGER AMENITIES AND MISCELLANEOUS WORKSSchedule 7B: Steel items

TOTAL FOR BILL No.7 B (Carried forward to Summary of Part-I)

S.No. Description of Item Quantity Unit

Page 15: Bill of Quantities Pkg-2

8001 Supply of 43/53 grade cement OPC/PPC conforming to relevant IS specifications and using the same in the work as per RVNL'sapproved mix design as per RVNL's prescribed rates of consumption including all lead lift, labour, loading unloading, ascent, descent,crossing of Railway lines(s), royalty, taxes, transport (contractor's own), tools and plant complete.

438002 Bag

Note: OPC or PPC cement has to be supplied as per requirement of the work in terms of RVNL standard specifications for material and works. Payment against supply will be made only after consumption of cement in the relevant items of work.

Bill No.8 :-- Supply of Cement

SN ITEM OF WORK Quantity

Total for Bill No. 8 (Carried forward to Summary of Part-I)

UNIT Rates in Rs Amount in Rs

Package-2 : Arand - Lakhna Bill of quantities , Part-I

Page 16: Bill of Quantities Pkg-2

S.NSOR

Item.No Description of Work Unit QTY RATE (Rs.) Amount (Rs.)

1 37203 Supply of Outdoor signaling cable - 6 core x 1.5 sq.mm. in drum length of 1 Km. Kms. 602 37204 Supply of Outdoor signaling cable - 12 core x 1.5 sq.mm. in drum length of 1 Km. Kms. 703 37206 Supply of Outdoor signaling cable - 19 core x 1.5 sq.mm. in drum length of 500 mtr

Kms. 128

4 37207 Supply of Outdoor signaling cable - 24 core x 1.5 sq.mm. in drum length of 500 mtr Kms. 72

5 37208 Supply of Outdoor signaling cable - 30 core x 1.5 sq.mm. in drum length of 500 mtr Kms. 32

6 38651 Supply of Railway underground jelly filled 6 Quad cable, 0.9mm dia. as per spec.No. TC/30/05 or latest for RE area. Km. 80

7 38759 Supply of LED signal unit for main signal FOR RED/YELLOW/GREEN aspect Nos 270

8 38801 Supply of DC Track circuit Equipment including battery charger, `B' type choke, adjustable Track Feed Resistance, QTA2 relay, QSPA1 relay, Fuse block, ND type fuses, 80 AH batteries etc.

Set 194

9 38811 Electrical point operating machine - IRS Type,220 mm throw with lock & detector slides, Cable terminal box and Clamp lock arrangement with Ground connections for thick web switches

Nos. 60

10 38821 Location box -Full Case complete with E type lock, Hylam sheet, Universal lock with key.Nos. 246

11 38851 Electrically operated lifting barrier assembly along with Dual tone warning bell (hooter) for LC Gate. Sets 11

12 39651 Excavation of trenches at the depth of 1.0 Mtr. deep and 300 mm wide and back filling the trench after laying of cable with supply and fixing of cable route marker. Kms. 92

13 39802 Bonding of track circuits on track, track connections, installation, jumpering, charging of batteries, testing & commissioning of DC track circuits on track including supply of Fiber Glass track lead junction boxes, Nylon Insulation rail joints etc.

Per Track Circuit 194

14 39901 Supply and installation of MAINTENANCE FREE EARTHING AND BONDING SYSTEM. Nos. 86

Total for Bill No.10 (Carried forward to Summary of Part-I)

Package-2 : Arand - Lakhna Bill of quantities , Part-I

BILL NO:10-SIGNAL & TELECOM DEPARTMENT

Page 17: Bill of Quantities Pkg-2

1005 Mechanical compaction of earth and blanket materials in layers of 30 CM in loose state using vibratory compactors so as to achieve minimum insitu dry density of 98% of maximum dry density. 966492 Cum 11.31 10,931,025

1007 Providing and erecting safety fencing by fixing minimum 75 MM dia 2.10 M long wooden bally posts at 3.0 M interval embedded in M10 cementconcrete block of 45 CM x 45 CM x 60 CM (with Contractor's cement) and interconnected with five rows of 12 MM dia nylon rope of approvedcolour and quality and maintenance in proper position throughout the period of requirement. 2 bands (red and white) 300 MM long shall bepainted on the ballies from top and 2 bands (100 MM apart) of yellow luminous tape of width 50 MM shall be pasted on top white band. Afterexecution of all works requiring safety fencing in particular stretch, the fencing shall be removed with the approval of the Engineer and formationshall be repaired to its profile and released materials will be contractor’s property.

68936 Meter 91.46 6,304,887

1008 Cutting down trees and uprooting of roots including transporting the wood to nearby railway store or forest godown as per direction of theengineer. Note: Clearance of trees with girth less than 60 CM and their clearance is covered under item No. 1001 & 1002. Girth will be measured at a heightof 1 M above ground level.

1008 c Girth above 180 CM and up to 270 CM 1216 Each 1243.69 1,512,327

1008 d Girth above 270 CM 811 Each 2473.23 2,005,790 20,754,029 Total for Bill No.1 (Carried forward to Summary of Part-II)

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.1 : EARTHWORK IN FORMATION

S.No. Description of Item Qty Unit Rate in Rs. Amount in Rs.

Page 18: Bill of Quantities Pkg-2

2001 Earth work in excavation in foundation of bridges to desired profile including backfilling, compaction of back fill, and disposal of surplusearth as per directions of the Engineer.

2001 a Soil excluding rock. 15908 Cum 97.21 1546417

2001 b Rock not requiring blasting. 2326 Cum 171.98 400025

2001 d Rock requiring blasting, but blasting not permitted, hence to be excavated by chiselling. 717 Cum 337.43 241937

2008 Providing and fixing elastomeric bearings as per specifications provided as per drawing. 1474800 CUCM 0.65 958620

2009 Providing and laying 40 MM expansion joint as per RDSO drawing No. B-1757R. 90 M 11029.46 992651

2010 Conducting deflection test of prestressed concrete deck with uniformly distributed static load as per clause 10.5 of IRS bridge code.

2010b 12.20 M PSC "I" Girder 2 Each 52249.73 104499

2010d 24.4 M PSC box Girder 1 Each 89263.85 89264

2016 Providing two coats of coal tar epoxy of 150 to 200 microns on R.C.C. substructures of bridges by roller or by airless spray after surfacepreparation. 24693 Sqm 145.81 3600486

2017 Providing and fixing bridge plaque (750 MM base, 720 MM height triangular section with 400 MM thickness) on both sides of parapetusing cement concrete of specified mix including engraving bridge number, direction of flow and other details including painting theletters with enamel paint of black colour of approved quality with white back ground as per standards of railway as directed by theengineer.

108 Each 197.22 21300

2018 Providing and fixing river name boards of size 2.10 M x 1.0 M made of MS sheet 6 MM thick and ISA 50 x 50 x 5 MM frame all around,fixed on rail posts erected with railway's rails fixed in cement concrete base of size 60 CM x 60 CM x 75 CM of CC 1:2:4 including paintingwith two coats of paint of approved quality and colour over one coat of primer, writing the name of the river in vernacular and English inblack colour with yellow back ground as directed by the engineer.

3 Each 3846.29 11539

2020 Conducting load testing on single pile or on separate test pile in accordance with IS: 2911(Part IV) including installation of loadingplatform, kentlage, preparation of pile head, construction and dismantling of test cap, etc.Note:Boring and installing of test piles shall be paid under item No.2024.

2020a Initial vertical load test. 3 Each 123193.46 369580

2020b Routine test. 3 Each 92441.83 2773252025 Providing and fixing of 100 MM dia PVC pipe for weep holes in abutments, wing walls, return walls, face wall, etc at suitable intervals as

directed by the engineer.2301 Meter 186.01 428009

2026 Providing and placing sand/earth filled bags in layers for protection of existing embankment. 3000 Each 6.54 19620

9061272

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.2 : BRIDGESSchedule 2A Bridge work (other than steel items)

S.No. Description of Item

Total of Bill No 2A (Carried forward to Summary of Part-II)

Qty Unit Rate Amount

Page 19: Bill of Quantities Pkg-2

2041 Supply and installing Casing pipe of 6 MM thick MS sheet for bored piles as directed by the engineer.

2041a For 1200 MM dia pile 600 Meter 11,029.46 6,617,676

2042 Providing trolley/men refuges, inspection ladder, hand railing, other miscellaneous components made of GI pipe/structural steelconforming to IS: 226 bolted/welded construction including fixing on bridges as per drawing and painting with one primer coat of redlead paint conforming to IS: 102 or zinc chromate paint conforming to IS:104 (with total DFT of 160 microns). Work shall be carried outas per I.S. 800.

2 MT 79,449.50 158,899

6,776,575

Amount in Rs

Total for Bill 2 B (Carried forward to Summary of Part-II)

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.2 : BRIDGESSchedule 2B Bridge work (Steel items Involving Fabrication and Erection )

S.No. Description of Item Quantity Unit Rates in Rs.

Page 20: Bill of Quantities Pkg-2

4001 Supply of P.Way Components

4001 a GFN Liners to RDSO Drg. No. T-3706. 114400 Each 7.22 825,968

4001 b Combination GFN liners to RDSO Drg. No.T-3707 and T-3708. 20035 Set 23.45 469,821

4001 c GRSP to RDSO Drg. No.T-3711. 249603 Each 19.85 4,954,620

4002 Supply of glued insulated rail joints G3 L 6.5 M long with 10 MM thick end post on PSC sleepers. Rails will be issued free of cost bythe Employer @ 6.5 M for each joint.

4002 a 60 KG rail section as per RDSO Drg No.RDSO/T-5843 294 Each 8674.59 2,550,329

4002 b 52 KG rail section as per RDSO Drg No.RDSO/T-5361 264 Each 7591.17 2,004,069

4004 Supply of Guard rails of 52 KG, 90 R rail sections for bridges including all fittings (excluding rail screw) required as per RDSOdrawing. Rails will be issued free of cost by the employer.

1543 Meter 216.5334,060

4005 Supply of Check rails of 60 KG, 52 KG, 90 R rail sections for level crossings, curves, etc. on PSC sleepers including all fittings as perRDSO drawing. Rails will be issued free of cost by the employer.

1754 Meter 541.26949,370

4006 Supply of PSC sleepers for bridges with provision for guard rails as per RDSO Drawing No. T-4088 for 60 KG rail. 713 Each 2056.791,466,491

4007 Supply of PSC sleepers for bridge approaches with provision for guard rails as per RDSO Drawing No. T-4089 to T-4097 for 60 KG rail. 38 Set 20748.3788,435

4008 Supply of PSC sleepers for level crossings as per RDSO Drawing No. T-4148 for 60 KG rail. 984 Each 2038.75 2,006,130

4009 Supply of PSC sleepers for SEJ as per RDSO Drawing No. T-4149 for 60 KG rail. 66 Set 13351.08 881,171

17,230,464

Payment Conditions for items of this Bill:1

a. Supplier's challan and manufacturer's challan.b. Inspection certificate issued by Employer's/Engineer's nominated inspecting agency.c. Comprehensive Insurance policy for the supply.d. Quality Assurance documents.e. Indemnity bond for entire cost of material supply.

2

Note :

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.4 : PERMANENT WAY SUPPLYPart 4 A: P.WAY SUPPLY (Other than Steel Items)

S.No. Description of Item Quantity

The remaining 10 % payment shall be made after commissioning of the portion of the work or handing over of the material to the employer's / Railway's Representative, required for maintenance purposes.The rate of PSC Special Sleeper, the transportation charges from Sleepers Manufacturing Plant to the supply point in the project area (as directed by Engineer) are inclusive. Item No. 5029 of Bill No.5 is for the further movement of the sleepers , in the Project area if required as per the site conditions.

Total for Bill No.4 A (Carried forward to Summary of Part-II)

Unit Rate in Rs Amount in Rs

90% payment shall be made on receipt, acceptance, accountable and taking into custody of complete materials including stacking of materials as per IRPWM and or guidelines issued by Railway fromtime to time at nominated locations. The invoices shall be accompanied by the following:

Page 21: Bill of Quantities Pkg-2

4021 Supply of P.Way Components

4021 d Supply of complete set of fittings and fastenings (excluding ERC. Liners, GRSP to Drg No.T-3711, fish plates, fish bolts and nuts) for60 KG 1 in 12 turnouts to RDSO lay out Drg. No.T-4218 58 Set 26160.90 1,517,332

4021 e Supply of complete set of fittings and fastenings (excluding ERC. Liners, GRSP to Drg No.T-3711, fish plates, fish bolts and nuts)for60 KG / 52 kg 1 in 8.5 turnouts to RDSO lay out Drg. No.T-4965 / T-4866. 9 Set 18493.05 166,437

4021 f Supply of rail screws to RDSO Drg. No.T-1035/10675 14816 Each 28.87 427,738

4022 Supply of Fish plates -

4022 a 60 KG as per Drawing No.T -1898 1116 Each 1204.30 1,343,999 4022 b 52 KG as per Drawing No. T- 090 (M) 806 Each 758.67 611,488 4023 Supply of Combination fish plates (4 Nos. per set) as per Drawing No.T696 to T699 including nuts, bolts and washers.

-

4023 a For 60 KG & 52 KG Rail Sections 246 Set 9472.05 2,330,124 4024 Supply of fish bolts with nuts for 60 KG, 52 KG rails as per RDSO Drawing No.T-1899, T-11501. 4828 Each 56.83 274,375

4025 Supply of joggled fish plates (2 No. per set) with 4 pair clamps, 4 No. Bolts & Nuts and 8 No. special washers.-

4025 a For 60 KG as per RDSO Drawing No.T -4016 276 Set 3292.67 908,777

4025 b For 52 KG as per RDSO Drawing No. EDO/T-620 43 Set 2580.01 110,940

4026 Supply of Fish plates one meter long as per standard drawing of RDSO -

4026 a 60 KG rail (As per RDSO Drg.No T-5916 / T-5851 ) 464 Each 1452.38 673,904

4026 b 52 KG rail (As per RDSO Drg.No T-5915 / T-5850 ) 32 Each 1163.71 37,239 4026 c Supply of screw clamps for fish plates 952 Each 974.27 927,505

9,329,858 Payment Conditions for items of this Bill:

1

a. Supplier's challan and manufacturer's challan.

c. Comprehensive Insurance policy for the supply.d. Quality Assurance documents.e. Indemnity bond for entire cost of material supply.

2

Unit Rates in Rs Amount in Rs

b. Inspection certificate issued by Employer's/Engineer's nominated inspecting agency.

The remaining 10 % payment shall be made after commissioning of the portion of the work or handing over of the material to the employer's / Railway's Representative, required for maintenance purposes.

Total for Bill No.4B (Carried forward to Summary of Part-II)

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.4 : PERMANENT WAY SUPPLYPart 4 B: P.WAY SUPPLY (Steel Items)

S.No. Description of Item

90% payment shall be made on receipt, acceptance, accountable and taking into custody of complete materials and stacking as per IRPWM and/or Railway guidelines at nominated locations. Theinvoices shall be accompanied by the following:

Quantity

Page 22: Bill of Quantities Pkg-2

5001 Training out ballast from measured stacks along side track or on formation and putting the same into track uniformly to form profileas per IRPWM in following phases: (i) Laying of first layer to form level bed for sleepers with top surface dressed to an accuracy of 10MM including mechanical compaction; (ii) Filling ballast in cribs and making up shoulders; and (iii) Recouping shortages after eachpacking and finally making profile as per IRPWM.

173334 Cum 78.65 13,632,719

5002 Training out ballast from ballast depots by railway hoppers/wagons from measured stacks including loading into hoppers/wagons andunloading on linked track in regulated manner to recoup shortages including redistribution and dressing up immediately after unloadingfor safe passage of trains and finally making profile as per IRPWM. 30000 Cum 48.92 1,467,600

5003 Cutting of 60 KG, 52 KG, 90 R rails true to square. - 5003 a Under traffic Block 1496 Each 57.55 86,095

5003 b Without traffic block 1638 Each 38.37 62,850

5004 Drilling 26.5 MM, 32 MM diameter holes in web of 60 KG, 52 KG, 90 R rails in track or on cess at correct locations includingchamfering. 4828 Each 29.74 143,585

5005 Transportation of rails, switches, crossings, etc. from point of issue to their final location of laying in track in correct direction ofrolling mark. -

5005 a Average lead, from the place of issue upto the middle point of location of laying in each KM, upto 10 KM 10120 MT 235.96 2,387,915

5005 b Incremental rate for lead beyond 10 KM under item 5005 (a) above 242869 MT KM 4.80 1,165,771

5007 Installation of PSC fan shape turnouts, derailing switches 60 KG / 52 KG including lead rails as per RDSO layout drawings includingkatcha packing with bars or off track tampers for 20 KMPH speed. Activities of rail cutting, drilling of holes, welding of joints andtransportation are not included in this item and shall be paid separately under relevent items. -

5007 a Turnouts 1 in 12 58 Each 38559.84 2,236,471

5007 b Turnouts 1 in 8-1/2 4 Each 36641.44 146,566 5007 c Derailing switches 9 Each 9208.32 82,875

5008 Incremental rate over Item 5007 a, b, c for installation under traffic block including adequate lighting arrangements for night working.This also includes pre-assembling the turnout parts at suitable location & leading & inserting the same in track under traffic block. -

5008 a Turnouts 1 in 12 29 Each 18800.32 545,209

5008 b Turnouts 1 in 8-1/2 2 Each 14867.60 29,735

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.5 : PERMANENT WAY LINKINGSchedule 5A : Installation Work

S.No. Description of Item Quantity Unit Rates in RS. Amount in Rs.

Page 23: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in RS. Amount in Rs.

5008 c Derailing switches 5 Each 5467.44 27,337

5009 Slewing of B.G. track comprising 60 KG, 52 KG, 90 R rails on all types of sleepers to any density under traffic block upto a lateral slew of150 MM or part thereof including removing and relocating existing ballast, packing with bars or off track tampers to achieve alignment,longitudinal levels and cross levels for running trains at a minimum speed of 20 KMPH on restoring traffic after the block and dressingup to correct profile.

7512 Track Meter 101.68 763,820

5009 a Incremental rate over item 5009 for slewing beyond 1st stage of 150 MM for each 100 MM or part thereof if done in the same trafficblock 3756 Track Meter 40.29 151,329

5010 Pre-tamping and post tamping works, reconditioning of tamping tools, and providing all consumables for first-round of packing by railway's heavy on track tampers and dynamic track stabiliser of straight/curved main line and loop line track, sidings, derailingswitches, and turnouts. Note: 1. For the purpose of payment: a. Length of turnout assembly, measured from stock rail joint to heel of crossing, shall be multiplied by 1.5 for conversion to equivalentordinary track; and. b. Derailing switches, bridges, level crossings, curves, etc shall be considered as ordinary track. 2. Transfer of machines from the existing running lines to the place of work and back to the running lines after the work is over shall bedone at contract's expenses without payment of extra cost 3. Railways heavy on track machines along with crew/operator shall be made available without any hire charges.4. 80% payment will be made if Dynamic track stabilser not used.

75121 Track Meter 20.14 1,512,937

5011 Pre-tamping and post tamping works, reconditioning of tamping tools, and providing all consumables for second-round of packing by railway's heavy on track tampers and dynamic track stabiliser of straight/curved main line and loop line track, derailing switches, and turnouts for raising speed to sectional speed. Note: 1. For the purpose of payment: a. Length of turnout assembly, measured from stock rail joint to heel of crossing, shall be multiplied by 1.5 for conversion to equivalent ordinary track; and b. Derailing switches, bridges, level crossings, curves, etc shall be considered as ordinary track. 2. Transfer of machines from the existing running lines to the place of work and back to the running lines after the work is over shall be done at contract's expenses without payment of extra cost. 3. Railways heavy on track machines along with crew/operator shall be made available without any hire charges.4. 80% payment will be made if Dynamic track stabilser not used.

75121 Track Meter 13.43 1,008,875

5012 Anticorrosive painting of 60 KG, 52 KG rails for loops and platform lines. Painting to be done prior to installation on sleepers includingtouching of paints in areas damaged during fixing. 14545 Track Meter 40.29 586,018

Page 24: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in RS. Amount in Rs.

5014 Provision of Buffer stop of 60 KG, 52 KG, 90 R rail section as per plan including painting with uminous paint etc. as directed by theengineer. Note:Rails required for this item will be issued free of cost by the Employer to the Contractor. 16 Each 27337.20 437,395

5015 De-stressing of LWR/CWR track with 60 KG, 52 KG rails at appropriate rail temperature as per LWR manual and as per directions of theengineer including adjustment of gap at SEJ, squaring & correct spacing of sleepers disturbed during the work. including greasing of ERCas per IRPWM. Payment for cutting of rails shall be made separately under relevant item. 75 Track Km 14963.52 1,122,264

5016 Laying of Sand humps / Snag dead ends as per RDSO standard drawing No: T-347 complete, with contractor's materials (excluding railsand PSC sleepers, fittings and fastenings which will be issued free of cost by the Employer within the Project area), machinery andlabour. Sand hump will be treated as a complete item including laying of track beyond back of crossing, making brick channels, dulyfilled with clean sand including dressing/raising of earth work as per the requirement at site, complete as per the standard railwaydrawings and specifications.

10 Each 120187.76 1,201,878

5017 Lifting of track in stages of maximum 75 MM at a time under traffic block including making up formation and one round of katchapacking for getting required longitudinal and cross levels to make the track fit for 20 KMPH as per provisions in IRPWM Para 233 and asdirected by the Engineer. (Rate will be for each stage lifting by 75 MM) . 75121 Track Meter 20.14 1,512,937

5018 Lowering of track in stages of maximum 75 MM at a time under traffic block including removing ballast, cutting of formation anddisposing of surplus cut spoils as directed by the engineer and one round of katcha packing for getting required longitudinal and crosslevels to make the track fit for 20 KMPH speed as per provisions in IRPWM Para 234 and as directed by the Engineer. Existing ballastshall be put back into the track after screening without any extra payment and shortage of ballast will be recouped and paid for underthe relevent item. (Rate will be for each stage of lowering by 75 MM).

1352 Track Meter 163.06 220,457

5019 Painting of station number, super elevation and versine at each station of curve on the inside web of outer rail with stencils ofspecified height in black enamel paint on surface of specified length painted with two coats of yellow enamel paint over a primer coatpainted after cleaning the surface free from dust and dirt. 7512 Station 47.96 360,276

5020 Supplying and fixing distance blocks of hard wood size 250x125x850 MM (length) between one side of rail of track and platform wall at30 M interval along the length of platform including painting of distance block. 495 Each 1170.22 579,259

5021 Dismantling the existing gate posts with lifting barrier, whistle boards, road sign boards and re-fixing of gate posts, lifting barrier,whistle boards, road sign boards at new location along the proposed alignment of track at manned level crossings (including painting onbarrier and posts, if required).Note: Concreting required for re-fixing shall be paid under relevant items

-

5021 a On both sides. 6 Level Xing 17937.04 107,622

5021 b On one side only 8 Level Xing 9304.24 74,434

Page 25: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in RS. Amount in Rs.

5022 Dismantling of the existing gate posts, whistle boards, road sign boards and re-fixing of whistle boards, road sign boards at newlocation along the proposed alignment of track at unmanned level crossings (including painting on barrier and posts, if required).Note: Concreting required for re-fixing shall be paid under relevant items -

5022 a On both sides. 11 Level Xing 10743.04 118,173

5022 b On one side only 16 Level Xing 4987.84 79,805

5023 Dismantling and removing of existing fencing at level crossing, leading and stacking of materials at nominated stores depot.588 Meter 59.47 34,968

5024 Dismantling of existing BG track, turnouts, derailing switches, dead ends, sand humps, etc. of any rail section and any type of sleepersof any density under block or non block conditions and transporting all released material including sleepers, rails, switches and crossingsto the nearest station or manned level crossing or road loading point as directed by the Engineer. -

5024 a Plain track 2165 Track Meter 90.16 195,196 5024 b Turnouts 1 in 12 21 Each 13716.56 288,048 5024 c Turnouts 1 in 8 1/2 17 Each 11606.32 197,307 5024 d Derailing switches 10 Each 7865.44 78,654 5024 e Sand Humps complete with rails, sleepers and fastenings and fixtures and levelling the area. 7 Each 11126.72 77,887 5026 Scarifying, digging existing caked Ballast upto the depth as directed by the Engineer, removal and screening of Ballast, removal and

disposal of muck, dressing of formation to the required profile and putting back the screen ballast in track. 3093Per Track

meter57.55 178,002

5027 USFD testing of new 60 KG, 52 KG rails as per RDSO Manuals and submitting reports on proforma as directed by the Engineer. 150 Rail KM 1342.88 201,432

5028 USFD testing of new 60 KG, 52 KG rail welds (Flash Butt / SKV) as per RDSO Manuals and submitting reports on proforma as directed bythe Engineer. 13587 Each 41.25 560,464

5029 Transportation of PSC sleepers including special sleepers for SEJs, check rails, guard rails and turn out sleepers from the place of issueto their final location of laying.Note: 1. For the purpose of payment each turnout sleeper will be considered as 1.5 No. of ordinary line sleeper. All other special sleepersshall be considered on par with ordinary line sleeper.(2) 100% payment shall be made on transportion to designated site as directed by employer/engineer. (3) The item is intended for transportation of sleepers issued free of cost by the employer or supplied by the contractor in P.Way supply schedule in the project area. However, if the sleepers to be issued free of cost by the employer are made available at the sleeper plantand loading of sleepers is done by concrete sleeper plant even then the rate quoted in the item shall be applicable subject to recovery@ Rs.10/- per track sleeper.

5029 a Average lead upto 2 KM (from place of issue to middle point of kilometre of laying in track) 125127 Sleeper 43.16 5,400,481

Page 26: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in RS. Amount in Rs.

5029 b Incremental rate for lead beyond 2 KM for every km additional lead upto 30 kms over item (a) above 3503567 Sleeper KM 1.44 5,045,136

5029c Incremental rate for lead beyond 30 KM for every km additional lead upto 60 kms over item (a) &(b) above 500510 Sleeper KM 0.55 275,281

5029(d) Incremental rate for lead beyond 60 KM for every km additional lead upto 250 kms over item (a), (b) &(c) above 500000 Sleeper KM 0.32 160,000

5030 Opening of road pavement at LC gate by breaking the pavement and removing the soil up to formation level to facilitate linking oftrack at LC gate and restoring road surface of movement of road traffic. 41 Level Xing 4028.64 165,174

5031 Painting of particulars of 1 in 12 and 1 in 8-1/2 turnouts and derailing switches including turn in curves on the inside web of outer railwith stencils of specified height in black enamel paint on surface of specified length painted with two coats of yellow enamel paint overa primer coat painted after cleaning the surface free from dust and dirt. 71 Turn Out 671.44 47,672

5032 Fouling marks of size 150x250x225 MM in M20 grade cement concrete including engraving the letters “FM”, white washing with twocoats and painting the letters in black enamel paint indicating the numbers of vehicles duly fixed at site. 62 Each 412.46 25,573

5033 Maintenance of track after commissioning at normal sectional speed till track is handed over to the Railway by deploying 1 gang of 25suitable persons headed by qualified P. Way supervisor. Attention to track to be done as per requirement to keep the track parameterswithin prescribed limits as per IRPWM for the sectional speed.

Note: In case additional/less gang deployment is done as per direction of the engineer, the payment shall be appropriatedproportionately

98 Week 27241.28 2,669,645

47,453,127 Total for Bill No.5A (Carried forward to Summary of Part-II)

Page 27: Bill of Quantities Pkg-2

5042 Supplying and fixing Boards for LWR, curves, level crossings (W/L board, speed breaker board and Stop board) made of 16 gauge M.S.Sheet with ISA 40x40x5 MM frame and ISA 75x75x6 MM posts as per drawings duly painted and lettered with luminous paint. 410 Each 1153.92 473,107

5043 Supplying and fixing retro reflective engineering signal boards of various sizes as per specifications given in Annexure 8/4 of Para 807 & 808 of IRPWM, made of 2 MM thick aluminium alloy sheet conforming to IS:736 in proper size, shape, etc. with back support of ISA 25x25x3MM. The entire face of the sign shall be covered with yellow high intensity encapsulated type retro-reflective sheeting with heat lampvacuum machine. The rate includes cost of supply and fixing post made of ISA 75x75x6 MM and of height enough so that the bottom ofboards are at 2.00 M above rail level and all nuts, bolts, rivets, washers etc. including after fixing in ground with 1:2:4 cement concrete baseof 45x45x45 CM.

5043 a Caution indicator boards of size 1400x400 MM. The back portion of the board shall be provided with black secthal film on the highintensity sheet base. 19 Each 4758.59 90,413

5043b Speed indicator boards of size of 1 M equilateral triangle. The speed figures shall be cut out of black secthal film and provided on the basesheet with HLYA process. 19 Each 4027.68 76,526

5043c Termination indicator of size 1 M diameter with letters T/G. The words T/G, T/P & T/EMU shall be cut out of black secthal film andprovided on the base sheet with ALVA process . 19 Each 4928.37 93,639

5044 Providing and fixing fencing at level crossing approaches as per the approved design and drawing made of MS flats 50x6 MM completealong with posts made of ISA 100x100x10 MM @ 3m centre to centre including casting of foundation in 1:2:4 (1 cement: 2 coarse sand: 4graded stone aggregate of 20 MM nominal size) cement concrete blocks of size 400x400x600 MM and other incidental works as perdirection of Engineer.

140 Quintal 7744.58 1,084,241

1,817,926

Package:2 Arand - Lakhna Bill of quantities, Part-II

Total for Bill No.5B (Carried forward to Summary of Part-II)

BILL No.5 : PERMANENT WAY LINKINGSchedule 5B : Supply and Installation works

S.No. Description of Item Quantity Unit Rates in Rs. Amount in Rs.

Page 28: Bill of Quantities Pkg-2

6001 Construction of service buildings at stations, in yards and in mid section as per layout drawing provided by the employer and detailedspecifications provided in para 4.2 of section 5: works requirements of the bidding documents including preparation of architecturalplan and structural design and drawings. Rate includes cost of cement steel and all other materials and labour.

6001 a Service building of single storey (foundation to be designed to take load of double storey) with open foundation upto 1.2 m depth fromground level and plinth height upto 0.6m from ground level with floor height upto 3.35m. 2073 Sqm 8859.22 18,365,163

6001 b Service building with double storey 428 Sqm 8063.27 3,451,080

Note: No extra payment shall be made for resisting earth quake forces in Zone II and single storey building in Zone III & IV.

6001 e Extra payment for provision of internal sanitary and water supply installations 1778 Sqm 2146.01 3,815,606

6002 Construction of residential buildings for staff accommodation near railway stations, level c crossings or any other nominated locationas per layout drawings and standard railway plans for each type of staff quarters, provided by the employer and detailed specificationsprovided in para 4.3 of section 5: works requirements of the bidding documents including structural design and preparation of detailedstructural drawings. Rate includes cost of cement steel, internal water supply and sanitary installations and all other materials andlabour.

-

6002 a Type I,II,III Single storeyed floor height upto 2.9 m 1313 Sqm 7304.39 9,590,664

6002 e Type IV/Type V Single storeyed floor height upto 2.9 m 85 Sqm 8336.62 708,613

6002 i Extra for every 0.3m additional height above normal height of 2.90 m130 SqM 152.89 19,876

6002 l Extra for every 0 .3 m or part thereof higher plinth over normal plinth height of 0.6m (on ground floor area only) 130 SqM 152.89 19,876

6002 n Extra for open foundation on poor soils having bearing capacity less than 10T per SqM (on ground floor area only) 130 SqM 291.88 37,944

6002 o Extra for foundation on poor soils requiring under reamed pile of 6m long (on ground floor area only) .130 SqM 3,148.59 409,317

6002 q Extra for making stronger foundations to take load of one additional floor at a later date (on area of additional floor only)130 SqM 439.21 57,097

6003 Construction of Water booths with granite cladding as per RVNL type plan. 28 Each 90714.14 2,539,996

6005 Providing precast RCC benches (chair type with back rest) as per RVNL drawing including fixing. 120 Each 10099.94 1,211,993

Amount in Rs

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.6 : BUILDINGS

S.No. Description of Item Quantity Unit Rates in Rs

Page 29: Bill of Quantities Pkg-2

Amount in RsS.No. Description of Item Quantity Unit Rates in Rs

NS1 Rain water harvesting-for recharging the natural ground by constructing infiltration gallery as per detailed drawing provided inspecification for civil works. The work consists of supplying and laying 110 mm dia UPVC pipe of 10kgf/sqcm working pressure as per IS4985, 100 m in length from roof of building to ground level and below ground level up to infiltration gallery as per site requirementincluding all specials, fittings, jointing materials and providing infiltration gallery duly excavating and filling with boulders, pebbles,aggaregates, sand, moorum and Netlon mesh as shown in drawinga vide item 7.9 Chapter 4 Section 6 of Technical Proposal provided at4.3.6, constructing inllet chamber with brick masonary 11 cm thick in 1:5 CM and plastering with 1:6 CM including supply of materials,labour plants equipments etc. complete as directed by Engineer in charge. Size of Infiltration Gallery shall be based on rain WaterPotential as per following:

a 25000-50000 litres 19 each 46445.19 882,459

b 50000-75000 litres 11 each 50546.10 556,007

c 75000-100000 litres 7 each 55696.08 389,873

d 100000-125000 litres 3 each 61990.50 185,972

e 125000-150000 litres 1 each 67426.59 67,427

f 150000-200000 litres 1 each 78298.77 78,299

NS 2 Exrta/deduction for PVC pipe under item NS1 for 110mm PVC pipe over/below 100m 1 m 280.39 280

42,387,541 NOTE In case of construction of laboratory block seperately constructed for the pessengers in station premises, the polyeurethane tanks sintax or equivalent are also to be provided with all plumbing works for

storage of water. Similarly, all loilets are to be provided with push/lever type flush arrangement. Rates are inclusive of all such connected works.

TOTAL FOR BILL No.6(Carried forward to Summary of Part-II)

Page 30: Bill of Quantities Pkg-2

7001 High level PF wall with precast RCC counterfort segments with design mix control concrete M30/M35 including transportation,hoisting and placing in position segments along with coping, excavation in trenches, laying of concrete bedding as per drawing, backfilling of trench, ramming, joining of segments complete as per RDSO drawing No. MA 10870. 904 Meter 1397.38 1,263,232

7002 Low level PF wall with precast RCC wall segments with design mix control concrete M25/M30 including transportation, hoisting andplacing in position segments, excavation in trenches, laying of concrete bedding as per drawing, back filling of trench, ramming,joining of segments complete as per drawing.

9944 Meter 1085.19 10,791,129

7003 Cement Concrete 1:2:4 (cast in situ/pre cast ) for Rail level platform wall, coping of platforms, drains and in other miscellaneousworks. 27372 Cum 1863.79 51,015,660

7004 Earth work in filling with contractor's earth of approved quality in platform, circulating area, level crossing and other areasincluding all lead and lift in layers not exceeding 30 CM in depth including mechanical compaction and watering to achieve thedesired compaction as per specifications.

35798 Cum 101.22 3,623,474

7005 Earth work in cutting in foundation, trenches, drains, etc in all kinds of soil including dressing of sides, ramming of bottoms, backfilling of trenches, getting out the excavated soil and disposal of surplus excavated soil with all lead and lift as directed by theEngineer.

-

7005 a In all kinds of soil 42445 Cum 97.21 4,126,078

7005 b In ordinary rock 6622 Cum 171.98 1,138,852

7005 c Hard Rock (requiring blasting) 219 Cum 277.61 60,797

7005 d Hard Rock ( blasting prohibited) 1863 Cum 337.43 628,632

7006 Cement Concrete 1 : 3 : 6 in foundation and floor. 1221 Cum 1757.24 2,145,590

7007 Providing platform surfacing using ; -

7007a Kota stone 25 MM thick on 20 MM cement mortar (1:4) bed including grinding, rubbing and polishing. 1888 Sqm 638.40 1,205,299

7007b Interlocking pavement blocks 100 MM thick over sand bed of 75 MM including edge restraints for confining the blocks as per RDSOdrawing #M-00003. 32741 Sqm 395.38 12,945,137

7007c Vacuum dewatered cement concrete 100 MM thick of M25 finished with screed board vibrator, vacuum dewatering process andfinally finished by floating, brooming with wire brush etc complete. 1525 Cum 2673.24 4,076,691

7007d Bricks on edge of class designation 75 over sand bed of 65 MM including filling of joints by sand. Sqm 233.68 -

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.7: PLATFORM, PASSENGER AMENITIES AND MISCELLANEOUS WORKSSchedule 7A: Other than Steel Items

S.No. Description of Item Quantity Unit Rates in Rs Amount in Rs

Page 31: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in Rs Amount in Rs

7008 Providing water bound macadam sub-base 100 MM thick as per profile for road, circulating area, etc using stone aggregate of 90MM to 45 MM size as per specifications including rolling of subgrade with all materials complete. 16205 Sqm 96.27 1,560,055

7009 Providing water bound macadam bearing course 75 MM thick as per profile using 50 to 25 MM stone aggregate of for road,circulating area, etc with stone aggregates as per IRC specifications including rolling in stages to proper grade and camber with allmaterials complete.

16205 Sqm 78.51 1,272,255

7010 Providing 40 MM premix carpet surfacing with 10-12.5 MM nominal size stone aggregate @ 5.4 COM per 100 Sqm and 54 kg hotbitumen per COM of stone aggregate complete with paving asphalt 80/100 heated and then mixed with solvent @ 70 Gms per KG ofasphalt. The rate also includes tack coat using hot straight run bitumen of grade 80/100 @ 0.75 KG per SQM and preparation of theexisting road surface as per specifications.

11344 Sqm 191.61 2,173,624

7011 Providing seal coat of premixed fine aggregate (passing 2.36 MM and retained on 180 micron sieve) with bitumen using 128 KG ofbitumen of grade 8500 per Cum of fine aggregate and 0.60 Cum of fine aggregate per 100 Sqm of road surface including rolling andfinishing with road roller complete.

11344 Sqm 37.39 424,152

7012 Providing bitumen penetration macadam with hard stone aggregate of specified size and grading and with bitumen of suitablepenetration grade including consolidation with road roller complete. -

7012a For 50 MM compacted thickness using coarse aggregate of size 40-20 MM graded and key aggregate of size 12.5 MM graded.11344 Sqm 224.33 2,544,800

7012b For 75 MM compacted thickness in two layers using stone aggregate of size 63-41 MM graded and key aggregate of size 20 MMgraded. 11344 Sqm 317.80 3,605,123

7017 Providing and fixing pre-painted galvanised sheet 0.6 MM thick with corrugated or trafford design on previously erected purlins orwall frame work for roofing. The colour coating shall be polyester coating over hot dipped galvanised sheet and the sheets will be ofminimum high tensile strength of 275 MPa variety. The fixtures used for fixing the sheets shall be as per manufacturerer'sspecifications. Measurement shall include area of MS sheet, valley gutter, ridges etc excluding overlaps. The rate includes provisionof 110 MM dia PVC rain water pipes, j bolts & other fixtures, painting of station name on both ends of COP in tri-lingual format.

2120 Sqm 534.65 1,133,458

7018 Providing GI pipes including laying & jointing with all fittings making connections to water hydrants including connection to sourcealong with excavation & refilling. etc. complete. (External Water supply only) -

7018a 15 MM Dia 3600 Meter 95.34 343,224 7018c 25 MM Dia 1283 Meter 159.83 205,062

7018d 40 MM Dia 363 Meter 224.33 81,432

7018e 50 MM Dia 8 Meter 285.08 2,281

Page 32: Bill of Quantities Pkg-2

S.No. Description of Item Quantity Unit Rates in Rs Amount in Rs

7019 Providing RCC station name board including fixing, painting and letter writing. 24 Each 8001.03 192,025 7020 Providing heavy duty Interlocking pavement blocks 150 MM thick made of cement concrete M35 or richer grade at level crossings

laid on sand bed of 75 MM over 300 MM well compacted granular sub base of well graded stone aggregate of 40 MM and down sizeand toe walls/edge restraints around the periphery for confining the blocks. 8610 Sqm 587.93 5,062,077

7021 Providing and fixing NON-asbestos, high impact poly-propylene reinforced cement corrugated sheets 6 MM thick in roofingincluding provision of valley gutters, ridges etc as per requirement, fixing with polymer coated J or L hooks, bolts and nuts 8 MM dia.G.I. plain and bitumen washers complete excluding the cost of purlins, rafters and trusses. 220 Sqm 299.10 65,802

7022 Brick work with bricks of class designation 75 for miscellaneous works in: -

7022a Cement motor 1 : 6 (1 cement : 6 coarse sand) 89 Cum 1873.14 166,709

7023 Dismantling work including removal and disposal of dismantled material outside railway boundary as directed by the Engineer.Dismantled material will be removed by the contractor at his own cost and the same will become the property of the contractor.Note: Measurement will be done before dismantling the structure. -

7023 a Water bound macadam/Bituminous road 102 Cum 230.87 23,549 7023 b Cement concrete 1012 Cum 373.88 378,367

7023 c R.C.C. work 102 Cum 547.73 55,868

7023 d Brick work/stone work 1696 Cum 346.77 588,122

7024 Dismantling steel structures and taking away dismantled materials as property of the contractor.2 MT -14020.50 -28,041

7025 Dismantling AC sheet roofing and taking away dismantled materials as property of the contractor.50 Sqm -4.67 -234

7026 Providing and fixing chequered terrazzo tiles 22mm thick with graded marble chips of size 6 mm in floors jointed with neat cementslurry mixed with pigment to match the shades of tiles including rubbing and polishing including laying on 20 mm thick bed ofcement mortar of 1:4(1Cement: 4Coarse Sand): medium shade using 50% white cement and 50% ordinary cement. 1320 Sqm 558.95 737,814

113,608,095 TOTAL FOR BILL No.7 A (Carried forward to Summary of Part-II)

Page 33: Bill of Quantities Pkg-2

7042 Manufacturing, supplying, installation and commissioning of 6-10 M long non-interlocked lifting barriers on either side of roadpassing through the level crossing within Railway limits with all accessories viz booms, fringes, boom loading device arrangement withits rod run and complete ground fitting, vertical wheel, diversion wheel, steel wire rope with its accessories pedestals, trunion bracket,LB drum, mechanical warning bell arrangement, night light, three lever frame etc complete including painting with fluorescent paint.Excavation & concreting of foundation will be paid separately.

2 Set 206007.88 412,016

7043 Providing single faces stove enamelled MS benches 1830x457x490 MM as per approved drawing complete. 84 Each 4869.79 409,062

7044 Providing India mark III hand pump (as per IS:13056-1991) with 25 M GI riser B class of 65 MM dia and 63 MM dia PVC suction pipeup to 5 M depth and 3 M long PVC ribbed screen 63 MM dia including packing with pee gravels and development.

10 Each 15,495.46154,955

7044a Incremental rate over item 7044 above for every 1 M or part thereof PVC suction pipe beyond 5 M depth 100 Meter 88.808,880

984,913

Unit Rates in Rs

TOTAL FOR BILL No.7 B (Carried forward to Summary of Part-II)

Amount in Rs

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL No.7: PLATFORM, PASSENGER AMENITIES AND MISCELLANEOUS WORKSSchedule 7B: Steel items

S.No. Description of Item Quantity

Page 34: Bill of Quantities Pkg-2

9001 Providing site offices for Employer with Contractor's material, Labour, Tools and Plant, Equipment etc. including provision of WaterSupply, Drainage, Power arrangements, office maintenance as per the details mentioned in clauses 3.1 to 3.2.8 & 3.5 to 3.5.2 ofChapter 3 (Site Facilities for the Employer and the Engineer) of Section 5 (Work's Requirement) of Tender Documents.Note 1: This item is provided with the contention that new site offices will be constructed for this purpose and 75% payment of the

accepted rates will be made after making available functional office, balance 15% payment shall be made at the end of the completionperiod and the remaining 10% will be paid after clearance of site by the contractor .Note 2: Alternatively if suitable accomodation is available on hire basis at suitable location acceptable to the employer, the contractorcan arrange the same under the item but in such a case the payment shall be regulated as below . (a) 10% payment shall be made on completion of one month from the date of making available the office fit for functioning.b) Remaining 90% payment shall be paid in equal monthly instalments that is (0.9xQuoted rate) / (Stipulated Completion period in

months + defect liability period in months). In case stipulated period gets extended on any account no additional payment shalll bemade for the item.

181 Per Sqm. of Plinth area

9543.98 1,727,460

9002 Providing Furniture as given under clauses 3.3, 3.3.1 of Chapter 3 (Site Facilities for the Employer ) of Section 6 (work's Requirement) of Tender Documents.Note : Payment shall be made @ 75% of the accepted rate after making available the furniture items in functional office, balance 15% payment shall be made at the end of the completion period and the remaining 10% will be paid after clearance of site by the contractor.

1 L S Per Site

Office 741280.00 741,280

9003 Providing Road Vehicle mentioned below for the use of Engineer/Employer as per the Conditions mentioned in Clause 3.4.3, i.e.3.4.3.1 to 3.4.3.3 of Chapter 3 (Site Facilities for the Employer and the Engineer) of Section 6 Work's Requirement) of TenderDocuments.

-

9003 a Tavera , Innova or similar 126 Vehicle months

39843.80 5,020,319

9003 b Tata Sumo, Bolero/Scorpio or similar 336 Vehicle months

34284.20 11,519,491

9003 c Extra for running and maintenance of every additional km over and above kms included under item 9003 (a) 1000 Per Km 9.27 9,270

9003 d Extra for running and maintenance of every additional km over and above kms included under item 9003 (b) 1000 Per Km 7.41 7,410

19,025,230 Total for Bill No. 9 (Carried forward to Summary of Part-II)

Package:2 Arand - Lakhna Bill of quantities, Part-IIBill No.9 : Site Facilities

SN ITEM OF WORK Quantity UNIT Rates in Rs Amount in Rs

Page 35: Bill of Quantities Pkg-2

S.NSOR

Item.No Description of Work Unit RATE (Rs.) QTY AMT (Rs.)

15 38657 Supply of Metal free Optical Fibre Cable 24 fibre as per TEC Generic requirement No. GR/OFC-01/04 Sep. 2003with latest amendment in drum length of 3 km. Km. 54954.04 17 934218.68

16 38702 Supply of DWC pipe of size 120 mm outer dia & 102 mm inner dia. Mtrs. 170.94 6400 1094016.00

17 38703 Supply of SPLIT DWC pipe of size 200 mm outer dia & 175 mm inner dia. Mtrs. 212.97 8200 1746354.00

18 38704 Supply of Galvanized Iron pipe 100 mm dia `B' class with end clamps Mtrs. 738.87 1054 778768.98

19 38705 Supply and jointing of Quad cables with thermo shrinkable jointing kits. Nos 3670.08 36 132122.88

20 38751 Supply of Colour light signal (2 aspect) having following items : (a) Signal post (b)Signal base C I 140 mm dia. (c)CLS ladder complete with platform and signal front staging (d)CLS unit 2 aspect (e)Anchor bolt with nut washer, Universal lock with key etc

Nos. 26485.47 32 847535.04

21 38752 Supply of Colour light signal (3/4 aspect) having following items : (a) Signal post (b)Signal base C I 140 mm dia.(c )CLS ladder complete with platform and signal front staging (d)CLS unit 3 aspect (e)Anchor bolt with nutwasher Universal lock with key etc

Nos. 31418.45 52 1633759.40

22 38753 Supply of Junction type route indicator (1 way) along with OFF set bracket and universal lock with key.Nos. 19732.86 6 118397.16

23 38754 Supply of Junction type route indicator (2 way) along with OFF set bracket and universal lock with key.Nos. 23020.89 8 184167.12

24 38756 Supply of Independent shunt signals complete with post, surface base, Position light shunt signal unit,Anchorbolts universal lock with key.etc. Nos. 8400.36 12 100804.32

25 38758 Supply of Calling on signal along with unituniversal lock with key. Nos. 2608.94 12 31307.2826 38760 Supply of LED signal unit for junction type route indicator/ shunt/ calling-on. Unit 4620.06 120 554407.2027 38812 Electrical point operating machine - IRS Type,143 mm throw with lock & detector slides, Cable terminal box etc

with suitable ground connection. Nos. 54915.74 24 1317977.76

28 38822 Location box - Half Case complete with E type lock, Hylam sheet, Universal lock Nos. 10866.39 126 1369165.1429 38824 Supply of Phoneix contact modular Terminal block 4 conductor test - disconnected type, type: UDK-4-MTK-P/p

with test & measurement facility with screw type clamp suitable for 1.5 sq.mm to 2.5 sq.mm conductor withcurrent carrying capacity of 16 amp as per RDSO spec. no. RDSO/SPN/189/2004 with end plate guide rail enstop & zack strip marker.

Nos. 54.78 22500 1232550.00

30 38901 Supply of office furniture set for relay room consisting of chairs, office table, Airy revolving & tilting cushion chair,steel Almirah, steel tool, of Godrej make. Nos 39897.28 17 678253.76

31 38902 Supply of Electronic magneto telephone desk type Nos 2167.11 62 134360.82

32 38903 Various types of markers as:-AP/C/G/A/IB markers Nos. 494.14 66 32613.24

33 38904 Tools for testing - Digital multimeter of fluke make- 1no, Digital Clamp type AC & DC Ampere Meter - Flukemake- 1no. SET 5885.76 17 100057.92

34 38905 Maintenance tool kit complete as per list attached. Nos. 73988.19 17 1257799.23

Package:2 Arand - Lakhna Bill of quantities, Part-II

BILL NO:10 SIGNAL & TELECOM DEPARTMENT

Page 36: Bill of Quantities Pkg-2

35 39307 Design and Development of OUTDOOR SIGNALING DRGS FOR ONE NEW PI/EI/RRI STATIONS Per station 89246.00 7 624722.00

36 39309 Design and Development of OUTDOOR SIGNALING DRAWINGS FOR ONE IBH / ONE MIDSECTION LCGATE / C CLASS STN Per Station 24840.00 1 24840.00

37 39652 Excavation of cable trench of 1 m. depth & 300 mm. wide across the track crossing, road crossing, levelcrossing, platform & refilling. Kms. 46417.00 16 742672.00

38 39654 Perforation and Fixing of GI pipes on girder bridges, RCC bridges, drains, culverts, rocky places tunnels/deepcutting. Mtrs 33.00 1054 34782.00

39 39655 Fixing/ laying of DWC/RCC pipes Kms. 27181.00 7 190267.0040 39656 Laying of signaling / power / telecom / quad/OFC cable of various sizes in trench and pipes. Kms. 3726.00 420 1564920.00

41 39657 Placing of half round ( Split DWC ) pipe over the laid cable in open trenches Kms. 2417.00 12 29004.0042 39659 Testing of point to point insulation / continuity test for all laid out cables, Measuring Parameters and preparing

the records Stn./IBH 35204.00 7 246428.00

43 39751 Excavation of pit, casting & plastering of concrete foundation for C.L.Signal and for signal ladder. Erection andwiring of complete signals along with supply of Signal number plate ,wiring material etc. Signal 10130.00 105 1063650.00

44 39752 Excavation of pit, casting & plastering of concrete foundation for Shunt .Signal and for signal ladder. Erectionand wiring of complete signals along with supply of Signal number plate ,wiring material etc. Signal 3131.00 12 37572.00

45 39801 Fixing & wiring of track circuit equipment in location box/Gumties including supply of wiring materials.. Per Track Circuit 4653.00 194 902682.00

46 39811 Installation, wiring, testing and commissioning of point machine including supply of wire, GI bend pipe, insulationsets etc..

Per Point machine 10871.00 72 782712.00

47 39812 Excavation & Pulling out the old cable from existing point machines, insertion of old & additional new cablethrough GI bend pipe wiring, testing and commissioning of point machine.

Per Point machine 4103.00 12 49236.00

48 39821 Excavation of pit, casting of concrete foundations for Location Box-single Caseerection of location box, supply ofuniversal lock with key, Lamp holder 2pin with switch, wiring material, wiring, testing and commissioning. Location box 6732.00 246 1656072.00

49 39821 Excavation of pit, casting of concrete foundations for Location Box-single Caseerection of location box Half case, supply of universal lock with key, Lamp holder 2pin with switch, wiring material, wiring, testing andcommissioning.

Location box 3911.00 126 492786.00

50 39823 Wiring in Existing Location box. 805.00 12 9660.0051 39851 Design fabrication & supply of LC Gate indication panel Nos 3476.00 11 38236.0052 39852 Installation, wiring, testing and commissioning of Electrical/Mechanical Lifting Barrier including supply of key

transmitter as per requirement. Per Gate 12763.00 11 140393.00

53 39903 Supply and Installation of various boards like BSLB/GWB/SLB boards/Calling-on boards Nos. 11969.00 52 622388.0054 39904 Supply and Installation of Earth electrode & connection of Earth with equipments. Per earth 2007.00 200 401400.0055 39905 Supply and Fixing of RE Protective Screens on signals Nos. 1812.00 52 94224.0056 39906 Provision of temporary Goomtis for NI working including Provision of Public Address system complete with

Microphones, speakers etc in the yard during Non Interlocking work. Goomti days 2345.00 12 28140.00

57 39951 Painting, Letter writing , Numbering Termination particulars overall Indoor and Out door Gears at completeSTATION including LC Gate. Station 27701.00 6 166206.00

58 39952 Painting,Letter writing / Numbering Termination particulars - IBH/ MID SECTION INT LC GATE/Auto hut etc. IBH/LC Gate/ Auto

Hut7907.00 1 7907.00

Page 37: Bill of Quantities Pkg-2

59 39961 Release of complete indoor and outdoor equipment from stations/IBH/LCgates and Transportation to the S&Tdepot

IBH/LC Gate/ Auto

Hut59847.00 7 418929.00

60 39962 Shifting/ lifting of existing location boxes/ signals/Track lead boxes, junction boxes etc along with foundation toadjacent place to facilitate earth work/ clearing infringement etc at stations including IBH, LC gates etc. Station 16973.00 30 509190.00

61 39963 Loading, unloading and transportation of Signal and telecom materials. 100 TKM 364.00 1000 364000.0062 10111 Excavation of trench 1.65 Mtr deep 300 mm wide at the bottom along Railway line in soft Rock/ Murram/Hard

soil including cleaning of bushes etc including morrum soft rock hard soil mixed with boulders etc, this workinclude back filling trenches by excavated soil and ramming after laying required quantity HDPE pipe and cableas per schedule and instructions of Engineer in charge of site. (Note: Proportionate payment will be made incase of less depth, but in no circumstance less than 1.2 Mtr)

KM 98488.00 1 98488.00

63 10113 Location survey of cable route and preparation of tentative and final cable route plan as per approved format inthe section including supply of final route plan after the cables are laid and commissioned indicating clearly theexact position of of cable joints and other critical items with reference to central line of the nearest track in 06No of hard bound copies on white bound paper of A-3 size (well documented and bound with plastic covers) andsoft copy of complete drawing on CD

Km 1405.00 67 94135.00

64 10114 Supply of 300 AH capacity low maintenance batteries as per IRS 88/93 - Set of 24 No. at each station withrequired Nos of porceilin insulators. Set 72490.40 1 72490.40

65 10115 Transportation and Derivation joint with 2T transformer: jointing of six quad jelly-filled cable usingthermoshrinkable jointing kit. This includes tapping of nominated quad at a specified location shown byEngineer using miniature tapping transformer of 470 : 1120 ohm impedance ( to be housed in the joint) Theother end of the transformer should be connected to 10 pair jelly filled u/g telecom cable (Supply of cable iscovered under a separate item) which has already laid in the trench for this jointing purpose. After jointing, jointshall be filled up with C Compound mixed with Harderner. All the materials required for the work are to bearranged by the Contractor except Thermoshrinkable jointing kit, 2T transformer assembly and C-compound,which are covered under supply portion of the schedules. After jointing the cable thorough test such asinsulation test, continuity test, etc. to be carried out jointly with Engineer. If any defect or damage observedduring jointing, the contractor should redo the joint free of cost.

Nos. 1121.00 70 78470.00

66 10116 Transportation and Straight through joint with out transformer: installation of straight through joint as directed byengineer at site or joint without transformer for LC gates, pump house etc. The derivation joint includes tappingof nominated quad of 6 quad cable at specific location as indicated by engineer at site without using transformerto 10 pair PIJF cable already laid in the ground. All the materials required for the work are to be arranged by thecontractor except Theromo-shrinkable jointing kit, Y and C- compound, which are covered under supply portionof the schedules. After jointing the cable thorough test such as insulation test, continuity test etc., to be carriedout jointly with Engineer. If any defect or damage observed during jointing, the contractor should redo the jointfree of cost.

Nos. 1121.00 70 78470.00

67 10118 Supply of 2 MB programmable primary digital drop insert multiplexer with conference facility as perspecifications IRS:TC/68/2004 with latest amendments & other stipulations of tender document fully wired for 30channels complete with power supply unit, remote control supervision facility & all other accessories installationmaterials, manuals etc. It should have facility to accomodate data interface cards in multi drop mode & shouldbe able to support card needed for video conference.

No. 64153.09 1 64153.09

Page 38: Bill of Quantities Pkg-2

68 10119 Supply of VHF transreceiver set simplex, 25 watt similar to Kenwood model no. TK 7100 or motorolla make forway station (SM/ASM office) with base antenna 6.5 db omni directional, mode CP-22E and 30 meter RG-213 co-axial cable with connectors at both ends. This shall also include the power supply unit cum charger model BM-100 or similar.

No. 20277.12 3 60831.36

69 10120 Krone type MDF suitable for 200 Pairs complete with Integrated Protection Modules complete with latestspecification. It shall be approved by RVNL. Set 30299.15 2 60598.30

70 10121 Supply of 42U 19" covered racks for housing SDH and P-Mux equipments, DDF, FMS,.MDF using krone moduleetc. complete with all fittings, wired and equipped with integrated protection modules for all channels andadequate numbers of cooling fans, AC/DC power supply distribution panels, U-Link panels and other hardwareslike runway, ladders etc. It should be possible to lock all the equipments with only order wire telephoneremaining outside the rack. The rack should be of APW President/Rittal make. The compoents of the rack arespecified below. The components of the rack is specified below

No. 30241.34 2 60482.68

71 10122 Supply and Installation of rack mounted 24F FMS fibre part No. fms-1u 24FS 24 FP Raychem make including24 Nos 0.2 db FC/PC adaptors and 24 numbers 900 micron 1.5 meter FCPC pigtails. RDSO Spec No. :RDSO/SPN/TC-037-2000(ver.3) or latest.

No. 19795.38 3 59386.14

72 10123 subscriper loop interface cards (6 circuits per card). No. 24830.26 2 49660.5273 10124 ISDN interface (Two BRI Ports per card) No. 23315.30 2 46630.6074 10125 Spare 2000mAH Ni-Mh Battery suitable for above VHF set, 5 watt No. 1864.56 20 37291.2075 10126 Transportation and making of of OFC joint enclosure and splicing of Optic fibre cable (24 fibres) and testing as

per technical specification No. GR OJC-2/02 Sept 2003. All materials including Fusion splicing machine used forfibre splicing and, OTDR for testing and other teting materials if any shall be arranged by the Contractor. Nos. 4893.00 14 68502.00

76 10127 Supply of Jelly filled underground telecom. Cable 0.5mm dia, 50 pair as per specn.No. IRS:TC-41/97. Km. 111214.96 7 778504.72

77 10128 Fabrication,transportation, installation and fixing of emergency socket post of 50 mm GI pipe with base plate,box and emergency socket and wiring as per the approved drawing. Arrangement of fabrication shall be as perDRG no. DRM/S&T/RTM/2007/1. These emergency socket posts to be fixed along the cable route at everykilometre as directed by Engineer at site. This involves termination of 10 pair jelly-filled cable on the 6-pinemergency socket fixed in the emergency socket box fixed on the post supported on Rail. The post should beconcreted at its base and painted with alternate black and white colour. all material for fabrication including 50mm GI pipe to be arranged by contractor except supply of EC box with socket which is covered under supplyportion and NG Rail which will be supplied by RVNL, however rails are to be cut to proper size before erection ofpost.

Nos. 1549.00 25 38725.00

78 10129 Exchange loop interface cards (6 circuits per card). No. 18939.26 2 37878.5279 10130 Supply of Emergency Socket Box to RDSO drawing No. 15220 with socket six pin flat to RDSO Spec No. IRS:

TC. 42/87. Amdt. 1 or latest. No. 1325.93 25 33148.25

80 10131 Supply of 48 volts SMPS Power plant for exchange No. 52620.69 2 105241.3881 10132 Excavation of trench 1.65 MTR deep 300 mm wide at the bottom along Railway line in all types of normal soil

including cleaning of bushes etc. This work include back filling trenches by excavated soil and ramming afterlaying required quantity HDPE pipe and cable as per schedule and instructions of Engineer in charge ofsite.(Note: Proportionate payment will be made in case of less depth, but in no circumstance less than 1.2 Mtr)

KM 62740.00 38 2384120.00

Page 39: Bill of Quantities Pkg-2

82 10133 Transportation and Initial charging of lead acid low maintenance batteries This includes : Supply of sulphuricacid to approved specification, distilled water. Preparation of electrolyte. Charging & discharging of batteries ( 3cycles). - 2 V 300 amp hours.

Battery 1158.01 24 27792.24

83 10134 Excavation of Jointing pit and provision of joint chamber of 1.2 meter dia. of 60 cm height with 2- piece cover ontop and bottom cover with holes for drainage (reinforcement drawing will be as per technical specification). Thisincludes water cooling of chamber, backfilling and ramming of the trench after cable laying and consolidation ofsoil as well as disposal of soil as per plan as advised by site engineer.

Nos. 2913.38 14 40787.32

84 10136 Supply of OFC Splice Enclosure (24 fibre) of TVS/raychem/REPL make as per broad specification of TEC, SpecNo. GR OJC-2/02 September, 2003 or latest No. 2599.56 14 36393.84

85 10137 Supply of FRP cable route and joint indicator as per drawing No.RE/Tele/22/83A No 119.29 200 23858.0086 10138 Valve Regulated Lead acid cell 12V/60 AH as per specification IRS: S:93/96A for VHF set No. 6594.79 3 19784.3787 10139 Supply of Electronic magneto telephone desk type as per specn.No.IRS :TC79/2000.with latest amendment

No. 1856.30 10 18563.00

88 10140 Supply, installation and fixing of 3 meter, 50 mm dia. GI pipe on station roof and fixing the same on the parapetwall with suitable clamps or as approved by engineer, laying of feeder connector, mounting, of VHF antenna andwiring to connect the 25 watts VHF sets upto ASM's room.

Set 6059.83 3 18179.49

89 10141 Girder/Cement Bridge: Transportation and Fixing of perforated G I Pipe for entry of cables, on girderbridges,RCC bridges,drains,culverts,rocky places, tunnels/deep cutting of places & as advised by site engineer&concreting the ends with brick channalling at both ends as per drg. This includes trenching up to the requireddepth as decided by the site engineer , the pipes are to be fixed on the girder bridge by suitable fixtures at aninterval of 1 meter as per approved drawing . On masonary bridges or in rocky area GI pipes are to be providedwith masonary of size 300 mm x 300 mm at intervals of 2 meters. All material (G I pipes,nuts&bolts clampsmaterial for construction piollars MS Channel,flexible DWC pipe etc)will be supplied by the contractor As perdrawing no RE/42/172A & RE/S&T/ALD/SK/160/81 and RE/S&T/ALD/SK/104/01A

Meters 58.00 400 23200.00

90 10142 Painting of telephone mark with indicating the direction of the nearest Emergency socket on the OHE mastKM 286.00 67 19162.00

91 10143 Testing of fibres between short haul stations in both directions, by splicing the required fibres LS 6350.00 3 19050.0092 10147 Supply of C compund with Harderner Kg 448.71 30 13461.3093 10148 Supply of PSU (wall mounted 12 V, 7AH fully charged maintenance free valve regulated sealed lead acid

stationary battey along with battery charger as per RDSO Specn.72/97 for driving 4 wire DTMF way side controlequipmrnt complete

set 8833.74 2 17667.48

94 10149 Supply of 4 wire way station equipment as per Spec. no. TC. 38/97 or latest. No. 4332.91 3 12998.73

95 10150 Transportation and Installation and wiring of Primary Drop insert MUX with all accessories, surge and lightningprotection arrangements, FDF, ladder runway etc. This includes installing optical Pig tails, optical patch cordsetc. to the STM-1 equipment from Primary MUX equipment. This also includes installing all interface cards in thePrimary MUX and extending 48V bus supply wires and running PVC switch board cable over riun way to Kronetype DP with all surge and lightening protection complete for 30 circuits derived from primary MUX coveredearlier. This also includes testing, commissioning of the Primary MUX, documenting and supplying the testresults. (Commissioning of Desk Top terminals as per Tech.spec. is considered as part of this item)

Nos. 14478.00 1 14478.00

Page 40: Bill of Quantities Pkg-2

96 10151 Supply of steel almirah - office storwel of Godrej make or equivalent model of same make.Size 1980 x 915 x 486 approx with 4 shelves making 5 compartments without locker having locking door. No 11266.93 1 11266.93

97 10152 Supply of FCPC to SCPC 10 meter long patch cords with 0dB adaptors as per TEC spec G/OJC-01/03 Jan 99or latest. No. 1112.13 10 11121.30

98 10154 Supply of 20 pair Krone terminal complete with mounting arrangements with box. The item shall be suppliedfrom DOT/BSNL approved firsm only. No. 1089.19 10 10891.90

99 10155 Supply of portable Emergency telephone 4 wire as per spec. no. IRS TC:75-99 with latest amendment No. 1631.49 6 9788.94

100 10156 Supply of ultra isolation transformers 230 VAC/230VAC-1.5KVA with MOVR protection on either side to provide"x"protection and supply of crow bar suege protection circuit for 48 V DC side to providr "y"protection No 10818.50 1 10818.50

101 10157 Office table of model no T9 of Godrej or equivalent model of same make. with 3 drawers on left hand side & onelocker on the right hand side. Olive brown/green with duplicate keys. No 10562.75 1 10562.75

102 10158 Supply of 20 pair 0.5 mm switch board cable to RDSO Spec. IRS.TC.24-91 Mtr. 74.33 100 7433.00103 10159 Supply of 100 pair Krone terminal complete with mounting arrangements with box. The item shall be supplied

for DOT/BSNL approved firms only. No. 2692.24 3 8076.72

104 10160 Supply of VF Tapping Transformer to RDSO Spec. No. IRS.TC-22-76 of type 470:1120, 600:470, 600:1120.exact break up to be decided in consultation with engineer No. 633.14 12 7597.68

105 10163 Transportation and Installation,testing and commissioning of 48 V battery set ,battery chargers and ultraisolation transformers and its wiring with paramite wire supplied under supply schedule. This includes installationof necessary fuses etc,. Note: Before installation of batteries contractors has to ensure that batteries are fullycharged,

Set 5645.00 1 5645.00

106 10166 Supply of Paramite battery wire 51 strands each of 0.75 mm dia (Equal quantity of Red and Blue) Mtr. 51.39 80 4111.20

107 10167 Supply of 150 mm dia. RCC pipe in standard lengths of 2 meters with collars as per spec. No. IS:458, NP2Clasue, as protection to HDPE ducts and 6 quad cable below culverts/bridges/TSS/SP/SSP. Meters 105.52 30 3165.60

108 10169 Supply of Switch board cable 10 pair , 0.5 mm for indoor wiring. Mtr. 22.02 100 2202.00109 10170 Office chair of model no CH-1007 of Godrej or equivalent model of same make. No 2816.73 1 2816.73

110 10171 Supply of 3.5 digit multimeter of Fluke make No 2520.65 1 2520.65111 10172 Supply of Permanently lubricated HDPE pipe 40/33mm as per TEC specification no. G/CDS-08/02 Nov. 2004

with latest amendment if any, suitable for armoured 24 fibre OFC Cable including its accessories like plasticcouplers, end plugs, cable sealing plugs ,end caps etc.as per requirement.

Km. 41952.67 40 1678106.80

112 10173 Installation and commissioning of 4 wire way station equipments, power supply unit atSP/SSP/Station/TSS/AEN/PWI/SI offices/Residences. The installation of way station equipment and powersupply unit (supply covered under a separate item) shall be mounted on a MS angle rack. All the materials forinstallation, commissioning of 4 W equipment and power supply unit shall be provided by contractor.

Locn 2623.00 1 2623.00

113 10175 Supply of PVC wire coil of size 3/0.75 sq. mm(each coil of length 100 meters) to RDSO Spec. IRS:S-76/89Amdt. No.2 ( or latest) No. 833.18 1 833.18

114 10176 Rotary duct cutter for cutting the duct (with replaceable blades) No. 825.84 1 825.84115 10178 Supply of theromoshrinkable jointing kits as per RDSO Spec. No. IRS. TC77-2000/Amdt.1 ( or latest) for

derivation joints with 2T tranformer, suitable for 6 quad cable No. 2305.00 70 161350.00

Page 41: Bill of Quantities Pkg-2

116 10179 Supply of theromoshrinkable jointing kets as per RDSO Spec. No. IRS. TC77-2000/Amdt.1 ( or latest) forNormal (Straight joint) joints without transformer suitable for 6 quad cable No. 2115.07 70 148054.90

117 10181 4 wire, E&M, VF interface cards (8circuits per card). No. 25000.01 4 100000.04118 10182 Supply of 48V SMPS Power Plant for TELECOM EQUIPMENT with FR/FC Modules as per

SPEC.NO.RDSO/SPN/TL/23/99(VER.3) with Amendment no.1, 48 volts, 25 amps in N+1 configuration i.e. 2modules of 25 amps, with automatic switching between the modules.

No. 49527.46 2 99054.92

119 10183 Supply of VHF transreceiver simplex for mobile 5 watt. similar to Kenwood model no. TK 2170 or motorollamake with rechargeable 2000mAH battery. This will include suitable battery charger. No. 15732.25 20 314645.00

120 10185 Transportation of OFC,and Blowing of Optic fibre cable into the duct by using blowing machine and associatedworks. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, theHDPE duct is required to be attended and integrity to be tested from one chamber to another chamber by thecontractor at his own cost.

KM 8890.00 40 355600.00

121 10186 Transportation and Laying of various sizes of cables in trenches: Laying of quad cable,PIJF cable of differentsize in the excavated trench. This includes loading/unloading & transportation of cables to site. Wheneverseveral cables are to be laid separation of cables should be as advised by site engineer. This includesunwinding of cable drum using proper jigs without causing damage to cable.

KM 3726.00 40 149040.00

122 10187 Supply of Jelly filled underground telecom. Cable 0.5mm dia, 5 pair as per specn.No. IRS:TC-41/97. Km 68249.25 7 477744.75123 10189 Supply of managed Expandable Rack type STM-1 ADM L 1.1 as per technical specification no. TEC GR No.

GR/SDH-04/02 Mar 02 with amendment 1,2,3 &4 or latest with STM-1 aggregate interface, 21 E1s and 4 nos. of10/100 Base T Ethernet port order wire, power supply unit, sub-rack installation material and accessoriesmanual etc. The equipment should be fully wired for its ultimate capacity and provide redundancy for powersupply and synchronisation & other details as given in Chapter 3 (Model - TJ100MC1)

No. 138332.79 1 138332.79

124 10190 Transportation and Wiring installation and testing of Magneto Telephone at L C gates/ ASM Office as per siterequirement.Wiring of Magneto telephones and battery with contractors own material from DP Box toequipment/Telephone by using 25 mm PVC Pipe with clamps,bends etc.

Nos 51.00 10 510.00

125 10191 Installation of 100 pair Krone terminals on hard wood plank of size 8" x13" x1" plant and wiring. Nos. 127.00 3 381.00

33869358Total for Bill No.10 (Carried forward to Summary of Part-II)

Page 42: Bill of Quantities Pkg-2

Item No. Description of Items Unit Qty Supply Erection Total Supply Erection Total

1 2 3 4 5 6 7(5+6) 8(4x5) 9(4x6) 10(8+9)SECTION - A : ELECTRIFICATION OF STAFF QUARTERS

33001 Electrification of staff quarter complete with point wiring, circuit wiring,sub main wiring etc. with Fire Retardant (FR) PVC insulated,multistranded, copper conductor, single core cable on surface /inrecessed PVC conduits, along with provision of luminaries with lamps,call bells, ceiling & exhaust fans, distribution boards, loose wire box,geyser, energy meters in M.S. box including earthing with G.I. pipeelectrode etc. as per Scale of fittings, and cable sizes, no. of wirespermissible in each circuit and sub main/s etc. for each type of quarteras indicated in Explanatory Notes.

ii) Type - II quarter Each 12 20885 250620iii) Type - III quarter Each 8 26215 209720iv) Type - IV quarter Each 1 48500 48500

ELECTRIFICATION OF GATE MAN LODGES AT LEVELCROSSINGS

33002 Electrification of gate man lodge complete with point wiring, circuitwiring etc. with Fire Retardant (FR), PVC insulated, multistranded,copper conductor, single core cable on surface/in recessed PVCconduits including provision of luminaries with lamps, ceiling fan,distribution board, earthing with G.I.pipe electrode etc. as per Scale offittings, cable sizes, no. of wires permissible in each circuit and submain/s as indicated in Explanatory Notes.

Each 9 12354 111186

ELECTRIFICATION OF SERVICE BUILDINGS, PUMP HOUSE, SUB-STATION, OFFICES ETC.

33003(i) Wiring for light/ceiling fan/exhaust fan/call bell/light plug/group pointsetc. including circuit wiring, sub-main wiring with Fire Retardant (FR),PVC insulated, multistranded, copper conductor, single core cable onsurface/in recessed PVC conduits, distribution boards, sub distributionboards, earthing etc as required. Wiring shall be done as per sizes ofcables ,no. of wires permissible in each circuit and sub mains etc.asindicated in Explanatory Notes.

Point 752 771 579792 579792

33003(ii) Wiring for power plug point including circuit wiring, sub main wiring,with Fire Retardant (FR) PVC insulated, multistranded, copperconductor, single core cable on surface/in recessed PVC conduits,distribution boards, sub distribution boards, earthing with G.I.pipeelectrode etc as required. Wiring shall be done as per sizes of cables,no. of wires permissible in each circuit and sub mains etc.asindicated in Explanatory Notes.

Point 80 1415 113200

33003(iii) Extra for provision of industrial type iron clad plug socket with 32A DPMCB in M.S.Box

Point 18 386 6948

ELECTRIFICATION OF PASSANGER SHELTER AND SHEDS

Package:2 Arand - Lakhna Bill of quantities, Part-II

This schedule shall be read in conjunction with its Explanatory Notes and Technical Specifications for detailed description for various items included therein.Unit Rate ( Rs.) Amount (Rs.)

Bill No.-11 GENERAL ELECTRICAL SERVICES WORKS

20885 25062026215 20972048500 48500

12354 111186

771

1415 113200

386 6948

Page 43: Bill of Quantities Pkg-2

33004(i) Electrification of passanger shelter/shed complete with wiring for lightpoint or ceiling fan point in group point wiring system,point wiring forlight and fan, light plug (5Amps) point wiring as required, includingcircuit wiring,sub main wiring etc. with Flame Retardant (FR) PVCinsulated, multistranded, copper conductor single core cable on surfacePVC conduits, sub distribution boards for independent control oflighting and fan circuits, earthing with G.I. pipe earth electrode etc asrequired. Wiring shall be done as per sizes of cables ,no. of wirespermissible in each circuit and sub mains etc.as indicated inExplanatory Notes.

Point 260 771 200460

33004(ii) Wiring for power plug point including circuit wiring, sub main wiring,with Fire Retardant (FR) PVC insulated, multistranded, copperconductor, single core cable on surface/in recessed PVC conduits,distribution boards, sub distribution boards, earthing with G.I.pipeelectrode etc as required.Wiring shall be done as per sizes of cables,no. of wires permissible in each circuit and sub mains etc.asindicated in Explanatory Notes.

Point 32 1415 45280

33004(iii) Extra for provision of industrial type iron clad plug socket with 32A DPMCB in M.S.Box

Point 4 386 1544

SECTION - B: PROVISION OF LUMINARIES, FANS, WATERCOOLER ETC.

33005 Supply, installation, testing and commissioning of prewired 1x28watt, T-5, energy efficient, surface type luminary with epoxy powder coatedCRCA sheet steel housing with reflector cover, similar to Bajaj Cat.Ref. No.BTIR128 complete with electronic ballast, T-5 tube etc. &earthing etc. as required.

No. 562 1008 178 1186 566496 100036 666532

33006 Supply, installation, testing and commissioning of prewired 2x28watt, T-5, energy efficient street light luminary similar to Bajaj Cat. Ref. No.BTSLF228T5, complete with T-5 tubes, electronic ballast etc.on pipebracket of erected pole or on wall bracket & connections from junctionbox/overhead line/light point etc. to luminary with 1.5 sq.mm FRLSPVC insulated multistranded copper conductor single core cable &earthing etc as required.

No. 216 2040 360 2400 440640 77760 518400

33007 Supply, installation, testing and commissioning of metal halide streetlight luminary with MH lamp, on pipe bracket of erected pole or onwall bracket of class"B"G.I.pipe & connections from junctionbox/overhead line/ light point etc. to luminary with 1.5 sq.mm FRLSPVC insulated multistranded copper conductor, single core cable &earthing etc as required.

(i) 1 x 70 Watt similar to Crompton cat. ref MHSGN1107IH No. 54 3699 652 4351 199746 35208 234954(ii) 1 x 150 Watt similar to Crompton cat. ref MHSG2115IH/FG No. 179 4316 761 5077 772564 136219 908783

33008 Supply, installation, testing and commissioning of A.C. ceiling fancomplete with wiring the down rod with 1.5sq.mm FR, PVC insulated,copper conductor, single core cable, earthing etc. as required.

i) 1200 mm (without Regulator) No. 95 1042 183 1225 98990 17385 116375ii) 1400 mm (without Regulator) No. 99 1132 200 1332 112068 19800 131868

33009 Supply and fixing of stepped type, electronic fan regulator, 300 watts,on the existing phenolic laminated sheet cover plate of switch box,including connections,testing & commissioning as required.

No. 194 266 51604

33010 Supplying, installation, testing and commissioning of 11 watts, 230volts, 2 pin, compact fluorescent lamp (CFL) complete with electronicballast etc. as required.

No. 38 111 20 131 4218 760 4978

33011 Supply, erection, testing and commissioning of 300mm, 900 rpmexhaust fan suitable for 1-phase, 230 volts, AC supply systemcomplete with capacitor, louver shutters, grouting bolts with nuts,making opening/modification in the wall to suit the size of the fan,making good the damages, connections with 1.5sq.mm, FR, PVCinsulated, multistranded copper conductor, single core cable, earthingetc. as required.

No. 20 1681 296 1977 33620 5920 39540

771 200460

1415 45280

386 1544

266 51604

Page 44: Bill of Quantities Pkg-2

33012 Supply, installation, testing and commissioning of self containeddrinking water cooler 150 liters capacity (cooling capacity 150 Lts. perhour), conforming to IS:1475/1978 (latest version) suitable for operation on 230 volts+/-10%, 50Hz, AC supply system complete with allconnected standard fittings, accessories etc. and 5KVA , wall mounted,I.C. controlled electronic auto-voltage corrector conforming to relevantIS (latest version), suitable for operation on single phase 180 to 260volts, 50Hz incoming AC supply and output 200 to 230 volts A.C.supply, complete with time delay relay, voltmeter, instant start provision with push button switch, earthing etc as required.

Each 10 43140 7613 50753 431400 76130 507530

SECTION - C: L.T.SWITCH BOARDS AND FEEDER PILLARSupply, installation, testing & commissioning of cubical type, wallmounted, dust & vermin proof, LT switch board, conforming to IS:8623(latest version). LT switch board shall be suitable for operation on 3phase, 4 wire, 415 volt, AC supply system, fabricated with 16 SWGM.S. sheet, powder coated and complete with inter connections,instrument connections with copper conductor cable, copper bus bars250 amps., CT's, voltmeter, ammeter, LED type indication lights, cableglands, earthing studs etc. comprising of the following:

10 54592 545920

i) Incoming MCCB 125A, 4 pole, 35kA, fixed type (Ics=100%Icu) - 1Noii) Outgoing MCCB 63A, 25kA, fixed type (Ics=100%Icu) - 4 Nos

iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos

iv) Outgoing MCB 32A, double pole, 10kA - 6 Nosv) Sleeved/Epoxy coated copper bus-bar in bus bar chamber vi)Indication lights

Supply, installation, testing & commissioning of cubical type, wallmounted, dust & vermin proof, L.T switch board conforming to IS:8623(latest version), suitable for operation on 3 phase, 4 wire, 415 volt, ACsupply system, fabricated with 16 SWG, M.S. sheet, powder coatedand complete with inter connections, instrument connections withcopper conductor cable, 200A copper bus bars, voltmeter, ammeter,clustered LED type indication lights, cable glands, earthing studs etc.and shall comprise of the following:

49767 497670

(i) Incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) - 1No(ii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) - 3Nos (iii) Outgoing MCB double pole, 6-32A, 10kA - 20 Nos (iv) Sleeved/Epoxy coated copper bus-bar in bus bar chamber

Supply, installation, testing & commissioning of weather proof, L.T.feeder pillar (degree of protection not less than IP54), fabricated with 2mm thick CRCA sheet, conforming to IS:8623 (latest version), powdercoated, suitable for operation on 3 phase, 4 wire, 415 volt, AC supplysystem, including construction of 450 mm high brick masonry platform,inter connections, 200 amps copper bus bars, indication lights, cableglands, earthing studs etc. and shall comprise of the following:

56447

(i) Incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) - 1No(ii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) - 4Nos (iii) Outgoing MCB double pole, 40A, 10 KA - 4 Nos

(v) Sleeved/Epoxy coated copper bus-bar in bus bar chamber

33013 No. 46403 8189 464030 81890

10 42302 7465 423020 74650

33015(i) No. 10 47980 8467 479800 84670

33014 No.

564470

Page 45: Bill of Quantities Pkg-2

33015(ii) Supply, installation, testing & commissioning of weather proof, L.T.Feeder pillar (degree of protection not less than IP 54), fabricated with2 mm thick CRCA sheet, conforming to IS:8623 (latest version),powder coated, suitable for operation on 3 phase, 4 wire, 415 volt, ACsupply system, including construction of 450 mm high brick masonryplatform, inter connections, 250 amps copper bus bars, indicationlights, cable glands, earthing studs etc. and shall comprise of thefollowing:

67369

(i) Incoming MCCB 125A, 4 pole, 35kA (Ics=100%Icu) - 1 No(ii) Outgoing MCCB 63A, 4 pole, 25kA (Ics=100%Icu ) - 4 Nos(iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos (iv) Outgoing MCB 32A, DP, 10kA - 6 Nos(v) Modular digital time switch and 3 phase contactor 63 A -- 2 set.

(vi) Sleeved/Epoxy coated copper bus-bar in bus bar chamber

(vii) Indication lights

Supply, installation, testing & commissioning of weather proof, L.T.Feeder pillar (degree of protection not less than IP54), fabricated with 2mm thick CRCA sheet, conforming to IS:8623 (latest version), powdercoated, suitable for operation on 3 phase, 4 wire, 415 volt, AC supplysystem, including construction of 450 mm high brick masonry platform,inter connections, 400 amps copper bus bars for phases 200 amps. forneutral, cable glands, earthing studs etc and shall comprise of thefollowing:

104453

i) Incoming MCCB 250 A FP 35KA(Ics=100%Icu) Fixed Type - 1 Noii) Outgoing MCCB 125 A FP 35KA(Ics=100%Icu) Fixed Type - 2 Nosiii) Outgoing MCCB 63 Amps FP 25KA (Ics=100%Icu) Fixed Type - 4Nosiv) Outgoing MCB 40 Amps FP 10 KA - 4 Nosv) Outgoing MCB 32 Amps DP 10 KA - 6 Nosvi) Modular digital Time switch and 3 phase contractor 63 A -- 2 set(vii) Sleeved / Epoxy coated Copper bus-bar in Bus Bar chamber(viii) Indication lights

SECTION - D : EXTERNAL ELECTRIFICATION WORKS Supply and erection of 7 meters long, swaged type steel tubular poleconforming to IS-2713 /Part I to III/1980 (latest version) (designation410 SP - 3), with canopy type single /double pipe bracket 200 mm long(diameter of pipe bracket shall match with the inlet diameter ofluminaries to be provided) including digging of pit in ground, earthingetc. as required, complete with the following:

i) Double door, weather proof M.S. junction box (degree of protectionnot less than IP54) complete with MCB 6 amps, copper bus bar forlooping 4-core, 3 nos. LT cables and clamping with pole, as required.

ii) Casting of foundation with cement, sand &concrete aggregratemixture in ratio 1:3:6 and providing muffing up to 300 mm above ground level,as required

iii) Erection of GI pipe class 'B' ISI marked up to junction box forpassing cable. (Payment of G.I. pipe shall be made against the relavant BOQ item.)

i) 7 Meter long pole with canopy type single pipe bracket (for oneluminary)

No. 276 7207 1272 8479 1989132 351072 2340204

No. 5 57264 10105 286320 50525 336845

33016 No. 5 88785 15668 443925 78340 522265

33017

Page 46: Bill of Quantities Pkg-2

ii) 7 Meter long pole with canopy type double pipe bracket (for twoluminary)

No. 30 7438 1313 8751 223140 39390 262530

Supply and erection of 9 meters long, swaged type steel tubular poleconforming to IS-2713 /Part I to III/1980 (latest version) (designation410 SP - 30), with canopy, single pipe bracket 200 mm long (diameterof pipe bracket shall match with the inlet diameter of luminaries to beprovided), digging of pit in ground, earthing etc. as required completewith the following:-

12729

i) Double door, weather proof junction box (degree of protection notless than IP54) complete with copper bus bar, MCB 6 amps, for looping4 core 3 nos.LT cables and clamping with pole as required.

ii) Casting of foundation with cement, sand & concrete aggregatemixture in ratio 1:3:6, providing muffing up to 300 mm above groundlevel as required.

iii) Erection of GI pipe class 'B' ISI marked up to junction box forpassing cable.(Payment of G.I. pipe shall be made against the relavant BOQ item.)

33019 Supply and erection of GI pipe - class' B' ISI marked with accessoriesincluding bends etc. for support of cable with erected pole/recessing inwall/floor/passing earth strip OR passing cable as required:

ii) 40 mm dia Meter 374 171 30 201 63954 11220 75174iii) 50 mm dia Meter 444 222 39 261 98568 17316 115884iv) 65 mm dia Meter 256 280 50 330 71680 12800 84480vi) 100mm dia Meter 320 524 92 616 167680 29440 197120vii) 150mm dia Meter 96 853 151 1004 81888 14496 96384

ELECTRIFICATION OF FOOT OVER BRIDGE33021 Electrification of foot over bridge complete with 3.5 meter long, 50 mm

dia, G.I. pipe pole with GI pipe bracket, luminary with lamp, M.S.junction box, connection from junction box to luminary with 1.5 sq.mm,Flame Retardant (FR), PVC insulated, single core, copper conductorcable and earthing with G.I. pipe earth electrode etc. and as per Scaleof fittings indicated in Explanatory Notes NB- Due to covered FOB the item is included in PF Selter.

No 4 7177 28708

SECTION - E: POWER SUPPLY DISTRIBUTIONARRANGEMENT

33022 Supply, installation, testing and commissioning of 11kV/415 Volt,Delta/Star connected, copper wound, power distribution transformer(outdoor type) conforming to IS:2026 (Latest Version ), complete withall accessories as required.

(i) 100 kVA No. 4 143316 29459 172775 573264 117836 691100(iv) Extra for providing fencing and iron gate for above item as indicated in

explanatory notesKg 1200 44 11 55 52800 13200 66000

(v) Extra for construction of foundation (M20) for transformer installation asrequired

Cu.M 60 2773 881 3654 166380 52860 219240

33023 Supply, erection, testing and commissioning of 3 pole, 11kV, 400amps,gang operated switch complete with drop out fuses etc. as required.

No. 4 16937 3482 20419 67748 13928 81676

33018 No. 116 10819 1910 1255004 221560 1476564

7177 28708

Page 47: Bill of Quantities Pkg-2

Supply, installation , testing & commissioning of cubical type, floormounted, dust & vermin proof, multi-tier construction, 17 panel LTswitch board (each panel shall be in segregated compartment),fabricated with 2mm thick CRCA sheet with base MS channel100x50x7.5mm (nominal size), duly powder coated. The LT switchboard shall conform to IS:8623 (latest version) and shall be suitable foroperation on 3 phase, 4 wire, 415 volt, AC supply system. The switchboard shall be complete with inter connections, instrument connectionswith copper conductor cable, copper bus bars, front operatedswitchgears, selector switches, ammeter, voltmeter etc. on eachincoming and ammeter on each outgoing with LED type indicationlights, cable glands, earthing studs etc. and shall comprise of following:

706234

i) Incoming ACB 800A, 4 pole, 50kA (manual draw out type) with CTR400/5A - 2 Nosii) ACB bus coupler 800A, 4 pole, 50kA (fixed type) - 1 No

iii) On load change over switch 400A, 4 pole, utilisation cat. AC 23 - 1No.

iv) Out going switch fuse unit/fuse switch unit cat AC23 (TPN) withHRC fuses (250 Amp) - 4 Nos

v) Out going switch fuse unit/fuse switch unit cat AC 23 (TPN) withHRC fuses 125 Amp - 4 Nos. vi) Out going switch fuse unit/fuse switch unit cat AC 23 (TPN) withHRC fuses 63 Amp - 5 Nos. vii) Sleeved/epoxy coated copper bus-bar - 800A for phases and 400Afor neutral.

33028 Supply of single core 400 sq.mm, unarmored LT XLPE insulatedaluminium conductor cable 1.1kV grade, conforming to IS7098 Pt.I(latest version), laying in trenches of sub-station, filling of trench withdry ordinary sand and holding of cable on transformer and panel sidewith frame manufactured with MS angle 50x50x6mm & clamps of MSflat 50x6mm, including end termination with LT panel & transformerwith aluminium crimping socket, testing and commissioning asrequired.

Meter 270 513 91 604 138510 24570 163080

33029 Supply, erection / fixing of fire extinguishing equipments (ISI marked),Rubber mat (ISI marked), GI fire buckets filled with dry sand held onfree standing steel stand, First aid box with medicines (ISI marked) andassociated materials, Shock treatment chart on aluminium frame and6mm thick glass on front, schematic diagram of HT & LT installation &transformer data on white hylem sheet with aluminium frame &fixing/providing in the sub-station area as per details in explanatorynotes.

Set 6 37750 6662 44412 226500 39972 266472

33030 Supply of DG set with acoustic enclosure, complete with diesel engine,copper wound alternator, battery set, anti-vibration pads, fuel tank andall other accessories/equipments/protective devices etc and AMFcontrol panel conforming to relevant IS, fabricated with CRCA, 16SWG sheet, powder coated and comprising of incoming 4 pole, MCCB50kA, copper bus-bars, 4 pole, heavy duty contactors, multifunctionpanel meter for display of current and voltage on phases and lines,power factor, frequency, kWH, MD etc, LED indications lightsincluding connections with single core 1.1 kV grade LT XLPE insulatedaluminium conductor cable conforming to IS:7098 Pt-I (latest version),between LT panel, AMF panel and alternator and construction of plinthas per recommendation of manufacturer, installation, testing andcommissioning.

33025 No. 2 635611 70623 1271222 141246 1412468

Page 48: Bill of Quantities Pkg-2

(i) 82.5 kVA DG set with 160 amp, 4-pole, MCCB 50kA (Ics=100%Icu),250 amps copper bus-bars, 4 pole contactors 250amp.

Set 2 717224 79691 796915 1434448 159382 1593830

Page 49: Bill of Quantities Pkg-2

SECTION - F: EARTHING ARRANGEMENT 33032 Earthing with 3 meter long, 50 mm dia, G.I. pipe class 'B' earth

electrode, adding of charcoal or coke and salt to achieve earthresistance less than 5.0 ohms, providing masonry enclosure and MScover plate with locking arrangement etc. including connections with4mm G.I.wire from earth electrode to switch board/electrical equipmentas required.

Job 160 1584 280 1864 253440 44800 298240

33033 Earthing with 600mmx600mmx6mm thick G.I. earth plate, adding ofcharcoal or coke and salt to achieve earth resistance less than 1.0ohm, providing masonry enclosure and M.S.cover plate with lockingarrangement, watering pipe etc. as required.

Job 12 1759 310 2069 21108 3720 24828

33034 Earthing with 600mmx600mmx3mm thick copper earth plate, adding ofcharcoal or coke and salt to achieve earth resistance less than 1.0ohm, providing masonry enclosure and M.S.cover plate with lockingarrangement, watering pipe etc. as required.

Job 4 3108 548 3656 12432 2192 14624

EARTH CONNECTIONS

33035(i) Supply and laying 25 mm x 6 mm G. I. strip at not less than 0.50 meterbelow ground or in recess as required.

Meter 248 36 7 43 8928 1736 10664

(ii) Supply and laying 40 mm x 10 mm G. I. strip at not less than 0.50meter below ground or in recess as required.

Meter 168 58 10 68 9744 1680 11424

(iii) Supplying and fixing 40 mm x 5 mm copper strip on surface or inrecess or in 50 mm dia G.I. pipe as required.

Meter 192 461 81 542 88512 15552 104064

SECTION - G : CABLING33036 Supply, laying under ground/road/railway track/recessing in wall/floor,

in laid RCC/G.I. pipe etc. 1.1 KV grade LT XLPE insulated armoured,aluminum conductor cable conforming to IS:7098/Pt I (latest version)including digging of cable trench, sand cushioning, protective coveringwith second class bricks, refilling of trench with excavated earth,making good the damages, end terminations with aluminium crimpingsockets/lugs, provision of cable route markers, testing andcommissioning as required:

i) 2 Core 16 Sq.mm Meter 1391 154 39 193 214214 54249 268463iv) 4 Core 16 Sq.mm Meter 15680 198 49 247 3104640 768320 3872960v) 3.5 Core 35 Sq.mm Meter 3498 280 50 330 979440 174900 1154340vi) 3.5 Core 70Sq.mm Meter 6749 446 79 525 3010054 533171 3543225vii) 3.5 Core 120Sq.mm Meter 1780 704 78 782 1253120 138840 1391960viii) 3.5 Core 185Sq.mm Meter 3020 986 110 1096 2977720 332200 3309920

x) Extra for provision of cable route marker No. 360 186 10 196 66960 3600 70560SECTION - H : ELECTRIFICATION OF YARDS

Page 50: Bill of Quantities Pkg-2

33037 Supply, erection, testing & commissioning of hot dipped galvanised(inside & out side), 16m high mast system (in two sections), completewith accessories, foundation bolts with nuts, washers, anchor plates &templates etc. manufactured from special steel, head frame, 2-pointsuspension system with steel wire rope 6mm dia (7/19 construction),double drum winch, galvanised lantern carriage arrangement suitablefor 9 luminaries symmetrically arranged & control gear boxes andlighting finial etc.The mast shall have integral type power tool at thebase compartment for its raising and lowering operation, twin domeaviation obstruction lights with 100 watt lamp, control panel etc. Highmast shall be supplied complete with 2x400 watts MH luminarie(degree of protection IP-65) with control gear boxes, MH lamps, multicore flexible copper conductor cable, control panel suitable to controlcircuits for automatic switch ON and OFF for 50% & 100% lighting,earthing with GI pipe earth electrode etc. as required. High mast shallbe provided with fencing panel of size 2Mx2Mx1.5M in square shapefor protection of erected high mast tower. The cost shall also includeconstruction of foundation as per recommendation of manufacturer.

Page 51: Bill of Quantities Pkg-2

i) 16 Meter high mast system with 6 nos. 2x400 watts MH luminaries andMH lamps

Job 6 509539 56616 566155 3057234 339696 3396930

ii) 16 Meter high mast system with 9 nos. 2x400 watts MH luminaries andMH lamps

Job 2 543330 60369 603699 1086660 120738 1207398

SECTION - I: MODIFICATION OF 11 KV / 33 KV OVERHEADPOWER LINE CROSSINGS

33038 Supply of 33kV XLPE (E) insulated, armoured, 3-core aluminiumconductor cable of size 300 sq.mm, conforming to IS:7098/Pt.II/85 andlaying in already laid pipe under railway track/road and clamping withalready erected pole after passing vertically through existing GI PipeAND laying under ground including digging of cable trench, providingsand cushioning, protective covering with bricks, providing cable routemarkers, testing and commissioning as required. Work also includescoordination with Supply Utility Company for arranging power shutdown and returning and transporting of released materials.

Meter 800 3056 161 3217 2444800 128800 2573600

33039 Supply of 11 kV XLPE (E) insulated, armoured, 3-core aluminiumconductor cable of size 185 sq.mm, conforming to IS:7098/ Pt.II/85 andlaying in already laid pipe under railway track/road and clamping withalready erected pole after passing vertically through existing GI pipeAND laying under ground including digging of cable trench, sandcushioning, protective covering with bricks, providing cable routemarkers, testing and commissioning as required. Work also includescoordination with Supply Utility Company for arranging power shutdown and returning and transporting of released materials.

Meter 1000 1375 153 1528 1375000 153000 1528000

33040 Supply of outdoor type, heat shrinkable, end termination kit, suitable for3 core 300 sqmm 33kV XLPE(E) insulated, armoured aluminiumconductor cable and making termination, connections with overheadconductor, testing & commissioning etc.

No. 16 19457 2162 21619 311312 34592 345904

33041 Supply of outdoor type, heat shrinkable, end termination kit, suitable for3 core 185 mm² 11 KV XLPE(E) insulated, armoured aluminiumconductor cable and making termination, connections with overheadconductor testing & commissioning as required.

No. 20 6208 690 6898 124160 13800 137960

33042 Supply and erection of pre-stressed, cement concrete (PSCC) doublepole ( H Pole ) structure 11 meters long suitable for 330 KG workingload with top section 200 mm X 105 mm and bottom section 410 mm X140 mm complete with 4 nos. channel cross arms & 2 nos. crossbracing angles, clamps, bolts, nuts , anti climbing devices, dangerplates on the erected pole, galvanized stay set , casting of foundationfor poles & stays etc. as required.

No. 18 37483 4164 41647 674694 74952 749646

33043 Supply and erection of 11 KV Porcelain Disc insulator(120 KN)complete with galvanised iron hardware etc. including terminating with11KV / 33 KV overhead conductor and dismentelling works as required.

Set 102 675 75 750 68850 7650 76500

33044(i) Supply and laying of 200 mm dia RCC hume pipe, ISI marked, underthe Railway track/road etc. by digging of trench and back filling withexcavated earth after laying of pipe and making good the damages asrequired.

Meter 1400 250 28 278 350000 39200 389200

33044(ii) Supply and laying of 200 mm dia RCC hume pipe, ISI marked, underthe Railway track with trench less method and back filling of excavatedpits and making good the damages as required.

Meter 200 1241 138 1379 248200 27600 275800

SECTION - J: PROVISION OF PUMPS33045(i) Supply, installation, testing & commissioning of submersible pump set

to supply water @525 LPM at 50m height along with control panel etc.to operate on 3 phase, 415V, 50Hz, AC supply complete as per detailsin explanatory notes

Job 2 43982 4887 48869 87964 9774 97738

Page 52: Bill of Quantities Pkg-2

33045(ii) Supply, installation, testing & commissioning of submersible pump setto supply water 350 LPM at 40m height, along with control panel etc.to operate on 3-phase 415V, 50Hz, AC supply complete as per detailsin explanatory notes

Job 3 40278 4476 44754 120834 13428 134262

SECTION -K: MISC. WORKS33046 Co-ordination/liasoning and chasing with State Utility Company for

availing new electrical connection/augmentation of sanctioned load atstations, level crossings etc. including applying for load, collection ofestimates for loads, modification of power line crossings, arrangingpayment from RVNL, depositing payment to State Utility Company,arranging release of load & other related works. Payment to be madeto SEB for new connections, load augmentation, modification of powerline crossings etc. shall be made by RVNL.

Each Location

30 0 5273 5273 0 158190 158190

33047 Design and preparation of working & completion drawings of all HT/LTelectrical installations of the project section where work is carried outsuch as platform lighting, internal electrification of staff quarters, levelcrossings, station building, offices, power line crossings, power supplydistribution arrangements of stations /sub stations, electrification of sub-station buildings etc.& approval from the competent authority.

Job 1 0 108680 108680 0 108680 108680

Conducting check survey of the complete project section to compiledetails of all the existing LT, HT and EHT Power Line Electricaloverhead and underground power/telegraphic/other lines running alongor accross the track and recording measurements of horizontaldistances of structures from the existing & proposed tracks, verticalclearances of conductors & guard wire from rail level, angle ofcrossings w.r.t. track, height and type of towers/poles and preparationof lists as below:

1 85800

i) List of Overhead/Underground Crossings infringing the ''Regulationsfor Electrical Crossing of Railway Track,1987" with latest amendmentsand requiring modification. Proposed modification may also beindicated.

ii) List of Overhead/Underground Parallel Alignments infringing the''Regulations for Electrical Crossing of Railway Track,1987" with latestamendments and requiring modification. Proposed modification mayalso be indicated.

iii) List of Overhead/Underground Crossings/Parallel Alignments inconformity with the ''Regulations for Electrical Crossing of RailwayTrack,1987" with latest amendments not requiring modification.

SECTION - L : (GLOW SIGN BOARDS )

33048 Job 0 85800 0 85800 85800

Page 53: Bill of Quantities Pkg-2

33049 Supply, installation, testing & commissioning of out door type, singleside, /Double side Glow sign boards/Pictorial signage boards withsuspension /side mounting/wall mounting type arrangements asrequired, complete including internal wiring with 2x1.5sq mm FR PVCinsulated, multistrand, copper conductor single core cable on surfacePVC conduit, earthing with 1.5 sq mm FR PVC insulated multi strandcopper conductor single core cable conforming to IS 694(latest version)etc, acrylic sheet of thickness not less than 4mm on front side, G.I/Aluminium Sheet of 24 SWG on all 5 / 4 sides with louvers etc.asrequired. Depth of board shall not be less than 200mm. Erectionarrangement shall be as approved by Railways. Matter to be written /displayed on signboards shall be got approved before manufacturing ofboard .Provision of luminarie shall be based on sample calculationindicated in explanatory note. Glow sign board shall have degree ofprotection not less than IP 54 . (Payment for Double sided glow signboard shall be made @ 150% of the rate of single sided glow signboards)

Sq.Feet 528 196 34 230 103488 17952 121440

SECTION -N : DISMANTLING WORKS

33053 Dismantling of wiring installations of buildings, sheds, quarters etc.complete with luminaries, fans, distribution boards, L.T. Panels andassociated cables including accountal,stocking, transportation andhanding over of released materials to Electrical department asdirected by the Engineer and making temporary arrangements ifrequired.

Each Station

6 0 5000 5000 0 30000 30000

33054(i) Dismantling of erected pole/overhead conductor, GI wire, cross armbrackets, insulators, stay, luminary etc including accountal ,stocking,transporting, handing over the released material to railway’sauthorized official as instructed by the Engineer and making temporaryarrangements if required.

No. 36 0 500 500 0 18000 18000

Page 54: Bill of Quantities Pkg-2

33054(ii) Dismantling of Sub-Station equipments such as transformers, DG Set,HT & LT Panels, cables etc. at site including transporting, stocking andhanding over to Electrical department as instructed by the Engineerand making temporary arrangements if required.

Job 1 0 10000 10000 0 10000 10000

SECTION - O : (N.I Works )33055(i) Provision of temporary lighting arrangement with 1x40 watt F.L. tube

light fittings /flood light/halogen fittings and pedestral fans in temporarytents, buildings, goomties, on tracks, in yard area including wiring,cabling, earthing etc.as directed by the Engineer and as per siterequirement for non - interlocking period, including providing stand byD.G set of suitable capacity and deployment of staff for operation ofDG set as per site requirement.Note: Normal power supply may be used, up to sanctioned load, if surplus available at site.

Each station

6 0 15000 15000 0 90000 90000

33055(ii) Extra for operation and maintenance of temporary wiring installations,replacement of consumables, supply of diesel oil, lub oil etc foroperation of DG set etc.

Per day 6 0 2976 2976 0 17856 17856

SECTION - P : (additional requirement HT/LT X-ing modification)

NS-1 Supply and erection of 9 KV 5 KA distribution class lightning arrestorincluding connection to earth electrode through 8 SWG GI wire includingtransportation.

No. 30 652 19560 0 19560

NS-2 Supply and erection of 30 KV 10 KA station class lightning arrestorincluding connection to earth electrode through 8 SWG GI wire includingtransportation.

No. 24 4823 115752 0 115752

GRAND TOTAL (Section A to P) 36475137 5674249 4214938642149386

NOTE:-The above prices are inclusive of all costs(excluding exciseduty),levies and taxesetc.

1. Payments: a) 80% of the accepted supply shall be paid on receipt ofmaterial at site, after due inspection against indemnity bond . If forany item of work, price of material & erection is notseparately available, 80% of the item price will be considered assupply. b) Further payment of supply & erection cost to cover 90% oftheaccepted item price (supply and erection) shall be made aftererection. c) Balance 10% payment shall be released after satisfactorycommissioning and handing over of complete installation.

652

4823

Total for Bill No. 11 ( Carried forward to Summary of Part-II)

Page 55: Bill of Quantities Pkg-2

EXPLANATORY NOTESItem.No

Explanatory Notes INSPECTION AGENCY

GENERAL INSTRUCTIONS:1) Current RDSO specifications are mentioned here. However, whileprocuring only the LATEST RDSO SPECIFICATION will prevail and materialto be inspected as per latest specifications.2) Drawing number mentioned here are current and may be updated. Latestdrawings is required to be followed while execution of work.3) The quantities of subitems against each item are to becalculated/assessed and approval of Engineer to be taken beforeconsolidated procurement of such items and for arranging inspection byRDSO/RITES, as the case may be as indicated under Inspection Agency

ELECTRONIC INTERLOCKING WORK - SUPPLY36001 This includes supply of :a Supply of Electronic Interlocking (EI) System - complete as per technical specification of

Contract suitable for use in 25KV RE area and generally conforming to RDSOSpecifications No. RDSO/SPN/192/2005 or latest with amendments mainly consisting of:

Material as per IRS specn tobe inspected by RDSO.(LikeEI, Relays, Tagblock, Wires,data logger etc.) remainingother material by Engineer.

a) Microprocessor Equipmentb) Interface equipment/Relaysc) Optical/Copper interfaced) Point Operation Relayse) LED Lamp Proving Realysf) Signal & Point Fuses, Tagblocks with coverg) Interconnecting indoor cablesh) Wiring Materials

Page 56: Bill of Quantities Pkg-2

i) Maintence Terminal for as per Clause 5.1.5 & 7.2 of RDSO specfn. for online logging

j) Interface for data transfer to central monitoring unit through data loggerk) Inbuilt power supply equipment and busbarl) Relay racks, fixtures, mounting arrangements, Ladder, runway and accessoriesm) Protective devices like fuses, lightening protectors etc. as per requirement andrecommended by manufacturer and RDSOn) Interconnecting copper/optical cable along with interface to make connections betweenEI and CCIP with Panel Processor/VDU as per RDSO Cl. 5.1.4o) Termination of functions up to cable termination rack. p) Remaining other relays, wiring material etc., if any. q) Track repeater relay QSPA1 and CCIP shall be paid separately under separate supplyitem.r) IMPORTANT NOTE: Description of various modules, sub assembly and otheraccessories required for the above work with unit rate to be furnished by EImanufacturer/contractor.s) Compliance of RDSO Specification: Information to be furnished by purchaser1. Clause 5.1.4: Station Master is to be provided with CCIP only. However SM room andequipment room may be situated in two different building and therefore may be required tobe provided with augmented surge protection/Optical interface by EI Manufacturer.2. System output required to drive field gears - Relay interface3. The manufacturer shall advise complete list of items in a set required for EI systembefore placing demand for RDSO call letter.Quantity and total cost should be submitted bythe EI Manufacturer/Contractor by attaching as annexure.

b Supply of essential spares to the extent of 5% subject to minimum of one, for thecards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, lighteningarrestors, isolators, convertors etc used in the complete EI system. In addition spare to theextent of 5% subject to minimum of one for all type of interface relays with bases used inEI. Item-wise details of spares to be supplied with unit rates should be listed out by thetenderers in separate annexure.

Page 57: Bill of Quantities Pkg-2

c Supply of Tools and Instruments - Tool Kits and Measuring Instruments fortechnicians/Junior Engineers for testing & maintenance and repair at site and troubleshooting of hardware & software for EI systems as per manufacturer's recommendations.List of instruments & tool kits to be provided by the supplier along with number and unitprices.

36002 Payment under this item will be made for Electronic Interlocking supplied against item no36001 by calculating the functions controlled by EI as per Function Table enclosed withthe Bid document. Functions up to 125 is covered under item no 36001. For eachadditional function beyond 125, payment will be made against this item. Typical value ofeach function is indicated in the enclosed table and based on the actual number offunctions controlled by the EI, the total value of functions can be calculated.

36003 Supply of portable work station to run along with EI configuration tools, data inputs,simulation and functional testing, diagnostics and trouble shooting and commissioning ofEI system. Note: Work station should be capable of reconfiguring the system in case ofany alterations in the Yard or Interlocking in future. Hardware Configuration to be approvedby RVNL before supply.

AXLE COUNTER WORK - SUPPLY36101 Supply of Single section Digital Axle Counter System for monitoring track section as per

RDSOSpcn.No.RDSO/SPN/177/2003 with latest amendment. This will cover allequipments required to work the single track section clearance and consist of High FrqTx,Rx coil, track side digital axle counter unit, vital relay with relay box duly wired, Clamp,reset box, surge protection device etc. The set stands for the equipment required at eitherend of track section. The manufacturer shall advise complete list of items in a set requiredfor this system before placing demand for RDSO call letter.

RDSO

Page 58: Bill of Quantities Pkg-2

36102 Supply of Multi section Digital Axle counter for FOUR TRACK SECTIONS complete withFIVE DETECTION HEADS, one central evaluator, with reset arrangement and vital relaysQ style and necessary fitting arrangements required for fixing of detection heads as perRDSO/SPN/176/2005 (VER. 2) with latest amendments . The equipment must also include(i) MICRO CONTROLLER / EVENT LOGGER CARD WITH REQUIRED SOFTWARE. (ii)SURGE PROTECTION DEVICE. (iii) Installation material - Reduction plates, Deflectors,Mounting frames for evaluation computers, Counting head housing, LIghting protectionmodule with accessorries, Earthing bolt for counting head.The manufacturer shall advisecomplete list of items in a set required for this system before placing demand for RDSOcall letter.

RDSO

36103 Supply of Multi section Digital Axle counter for SEVEN TRACK SECTIONS complete withEIGHT DETECTION HEADS, one central evaluator, with reset arrangement and vitalrelays Q style and necessary fitting arrangements required for fixing of detection heads asper RDSO/SPN/176/2005 (VER. 2) with latest amendments . The equipment must alsoinclude (i) MICRO CONTROLLER / EVENT LOGGER CARD WITH REQUIREDSOFTWARE. (ii) SURGE PROTECTION DEVICE. (iii) Installation material - Reductionplates, Deflectors, Mounting frames for evaluation computers, Counting head housing,LIghting protection module with accessorries, Earthing bolt for counting head. Themanufacturer shall advise complete list of items in a set required for this system beforeplacing demand for RDSO call letter.

RDSO

36104 Supply of Multi section Digital Axle counter for FIFTEEN TRACK SECTIONS completewith EIGHTEEN DETECTION HEADS , one central evaluator, with reset arrangement andvital relays Q style and necessary fitting arrangements required for fixing of detectionheads as per RDSO/SPN/176/2005 (VER. 2) with latest amendments . The equipmentmust also include (i) MICRO CONTROLLER / EVENT LOGGER CARD WITH REQUIREDSOFTWARE. (ii) SURGE PROTECTION DEVICE. (iii) Installation material - Reductionplates, Deflectors, Mounting frames for evaluation computers, Counting head housing,LIghting protection module with accessorries, Earthing bolt for counting head. Themanufacturer shall advise complete list of items in a set required for this system beforeplacing demand for RDSO call letter.

RDSO

Page 59: Bill of Quantities Pkg-2

36105 Supply of AXLE COUNTER TOOL KIT: Required tools for tool kit must be recommendedby the manufacturer. Purpose of toolkit is to test, diagnose and calibrate the axle counter.However Tool kit for axle counter must consist minimum of (1)True RMS digital multimeterof Fluke make with probe set - 1 no. (2)Extended wired socket to interface with diagnosticplug - 1no. (3) Adjustable torque wrench with inserts (4) Double ended spanner (5) Dummywheel - 1 nos (6) Screw driver set (7) Carrying case.

RDSO

36106 Supply of Web detector (each set consists of 2 nos. of TX and 2 nos. of RX coils) forAnalog/Digital axle counters with complete components per detection points.NOTE: This item is required to shift the existing axle counters installed at stations from itspresent location to new location, thus existing make, type etc is to be checked beforeplacing orders.

ENGINEER

OUTDOOR SIGNALLING CABLE WORK - SUPPLY37201 to 37208

Supply of outdoor signaling cable : Cable Railway signaling unscreened underground withplain annealed copper conductor, armoured PVC insulated to conform to IRS-S-63/2007with amendment 2 or latest. For drum length conditions of IRS will be applicable. Drum no.and name of consignee to be painted on the cable drum.

RDSO

37209 Supply of Cable Railway PVC insulated, armoured unscreened, Stranded Aluminiumconductor power as per IRS-S:63/2007 (Amndt-2) & IS 1554 (Part-1) of type 2 Core x 25Sq mm.

RDSO

DESIGN & DRAWING WORK - SUPPLY38301 Supply of design set for circuit consist of desktop pc, intel pentium dual core with min 2GB

RAM, 140 GB harddisk, DVD drive, keyboard, optical mouse, 17" LCD monitor ofHP/DELL/Compaq/Lenovo make with printer A3 size of HP make. (Spec to be updatedwhile inviting tender)

ENGINEER

RELAYS - METAL TO METAL - SUPPLY38351 Supply of Point Chain Group No. RSSK 3515/03 of siemens type with relay base plate as

per RDSO spn.IRS-S-46RDSO

Page 60: Bill of Quantities Pkg-2

38352 Supply of Point Group RRI, Siemens type (No RSSK 3515/19) as per RDSO spn.IRS-S-46

RDSO

38353 Supply of Point Group PI, Siemens type (No RSSK 31/0001) as per RDSO spn.IRS-S-46 RDSO

38354 Supply of Route Group, Siemens type ( No RSSK 31/0002) as per RDSO spn.IRS-S-46 RDSO

38355 Supply of Signal Group, 3 Aspect Siemens type (No RSSK 3525/46) as per RDSOspn.IRS-S-46

RDSO

38356 Supply of Signal Group, 2 Aspect Siemens type (No RSSK 3525/2) as per RDSO spn.IRS-S-46

RDSO

38357 Supply of Shunt Signal Group Siemens type ( No RSSK 3526/67) as per RDSO spn.IRS-S-46

RDSO

38358 Supply of DC Neutral line Relays (Non AC Immunised) Mini Groups of 2 Nos. K-50 RelaysSiemens type (No. RSSK 30/0011) with contact configuration 4F/4B, 5F/3B, 6F/2B as perRDSO spn.IRS-S-46

RDSO

38359 Supply of Plug in type Interlocked Relays consisting of two nos. of DC neutral relaysSiemens type (No. RSSK 30/0012) IRS-S-46 contact configuration 4F/4B

RDSO

38360 Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (ACImmunised) Siemens type (No. RSSK 30/0078) or equivalent (Ref. IRS:S46)IRS-S-46contact configuration 4F/4B

RDSO

38361 Supply of Time Element Relay (Clock work type) AG timer Siemens type (No RSSK30/0052)

RDSO

Page 61: Bill of Quantities Pkg-2

38362 Supply of ON/OFF/ROUTE aspect ECR for Main Signal Siemens RSSK 30/0013 IRS:S46with bases suitable for LED signals

RDSO

38363 Supply of Key Lock Relay with different ward combinations (one extra set of ward plate forPoint Machine to be supplied with each relay). Siemens type.

ENGINEER

38364 Supply of Plug in type point group contactor relay siemens type operated on 24 V as perRDSO Specn.No.IRS-S-46/77 and firms Specification.

RDSO

RELAYS - METAL TO CARBON - SUPPLY38401 Supply of Relay DC miniature plug in neutral line tractive armature 24 V DC, contacts front

& back contacts metal to carbon complete with plug board retaining clip & connectors toBRS -930 A. IRS-S-34,IRS-S-23. Interlocking code ABCDE. - QN1 (Contact configuration12F/4B or 8F/8B)

RDSO

38402 Supply of Relay AC immune miniature plug in neutral line tractive armature 24 V DC,Contacts front & back contacts metal to carbon complete with plug board retaining clip &connectors. BRS -931 A as per RDSO Specn.No. IRS-S-34, IRS-S-23 IRS-S-60/78.-QNA1(Contact configuration 12F/4B or 8F/8B)

RDSO

38403 Supply of Relay miniature plug in TWIN neutral line tractive armature 24 V DC, Contactsfront & back contacts metal to carbon complete with plug board retaining clip &connectors. BRS -960 as per RDSO Specn.No. IRS-S-34, IRS-S-23 IRS-S-60/78.QNN1(Contact configuration 6F/2B or 4F/4B)

RDSO

38404 Supply of Relay miniature AC IMMUNISE plug in TWIN neutral line tractive armature 24 VDC, Contacts front & back contacts metal to carbon complete with plug board retaining clip& connectors. BRS -960 as per RDSO Specn.No. IRS-S-34, IRS-S-23 IRS-S-60/78.QNNA1 (Contact configuration 6F/2B or 4F/4B)

RDSO

38405 Supply of Relay plug in type QS3, Sensitive Neutral line relay 12V, 1000 Ohms, 4F/4B,complete with plug board retaining clips and connectors as per specification no.BRS 930 &IRS S34 &23. Interlocking code for this unit shall be CDEKX

RDSO

Page 62: Bill of Quantities Pkg-2

38406 Supply of Relay DC plug in neutral line 24 VDC, 1000 ohm, 6F/ 6B complete with plugboard, retaining clips & connectors etc. to BRS-930A, IRS-S-34/68, IRS-S-23/86 & IRS-S-60 similar to QN1K interlocking code BDEKX

RDSO

38407 Supply of Relay AC Immunise DC plug in neutral line 24 VDC, 1000 ohm, 6F/ 6B completewith plug board, retaining clips & connectors etc. to BRS-931A, IRS-S-34/68, IRS-S-23/86& IRS-S-60 similar to QNA1K interlocking code CDEKY

RDSO

38408 Supply of RELAY PLUG-IN TYPE, Style-QECX, AC LAMP PROVING RELAY (Metal-to-Carbon Contact), slow release, 4F-4B contact, suitable for working in series with 110V ACLED SIGNAL LAMP for ON/OFF/Route/Shunt/Calling ON aspect complete with plugboard, retaining clip and connectors. Confirming to BRS: 941A, IRS: S34&S23 &STS/E/RELAYS/AC LIT LED SIGNAL/09-2002.

RDSO

38409 Supply of Timer Relay Fail safe type of electronic time delay device - 24 Volt DC for Rly.Signaling as per Spec. No. IRS:S-61/2000 with latest amd. with a time setting of 120seconds

RDSO

38410 Supply of Electronic Flasher Relay, 60 flashes per minute as per RDSO spn no:RDSP/SPN/173/2002

RDSO

PANEL, RACK & FUSES WORK - SUPPLY38451 Supply of spare domino unit with cover plate as per approved panel diagram fully equipped

with LED bulbs, buttons and wiring etc to facilitate modification in operating panel,indication panel, control cum indication panel. Preference should be given for supply ofdominos from the original manufacturer of panel in which modification is to be done.

ENGINEER

38452 This includes:

Page 63: Bill of Quantities Pkg-2

a Supply of Indication cum operating panel with tag block completely wired with fullcompliments like operating, emergency push buttons, counters with sealing arrangement,SM's key depicting on LED indication of various functions in the yard layout such assignals, points, track circuit etc. and housed in a sheet metal cabinet. Each of the workingdomino should have all 15 terminals components. The panel should have polycarbonatesheet cover on the top. All fused LEDs shall be replaced by contractor during testingperiod. SPARE:10% of working domino with cover plate completely wired and 10% ofLEDs of each colour,10% (minimum three) of buttons, 10% of counter, 2 magnets, 1buzzer & 4 bulb extractors shall be handed over as spare after commissioning of theinstallation by the contractor. Tag block (if used) shall conform to RDSO specn. IRS-S-77/91.Manufaturer's name plate with address to be provided. Dominos of size 54 x 34mm.Payment will be made based on actual size of panel on per domino basis.

ENGINEER

b Supply of PVC Indoor Cable 1x60x0.6mm dia., PVC Insulated Multi Core unsheathed withplain annealed copper conductor as per IRS:S-76/89 Amndt - 3 Colour coding ofinsulation of inner core shall be in six colours viz. Blue, Red, Gray, Green, Brown andBlack - in Quantity as per requirement to make connection between Relay room and Panel

RDSO

c Supply of PVC Indoor Cable 1x 40x0.6mm dia. PVC Insulated Multi Core unsheathed withplain annealed copper conductor as per IRS:S-76/89 Amndt - 3 Colour coding ofinsulation of inner core shall be in four colours viz. Yellow, White, Pink and Violet - inQuantity as per requirement to make connection between Relay room and Panel

RDSO

38453 This includes supply of:a Main Cable Termination rack complete with scaffolding, fixtures and accessories including

mounting arrangement (10 mm thick Hylam or any other suitable arragement) for fixingeight way terminal blocks/ARA/ Modular terminals, along with supply of ladder, string rods,frame,base assembly, insulators, J bolt, nut/bolts & fasteners etc. & as per extent practiceon Railway

ENGINEER

Page 64: Bill of Quantities Pkg-2

b Supply of PVC indoor cable 1 x 24 x 1 mm dia. PVC Insulated Multi Core unsheathed withplain annealed copper conductor as per IRS:S-76/89 Amndt - 3 Colour coding ofinsulation of inner core shall be in six colours viz. Blue, Red, Gray, Green, Brown andBlack - in Quantity as per requirement for patching between Old and New CT Tack

RDSO

38454 This includes:a a) Supply of Relay Rack Assembly (SIEMENS STYLE) complete with scaffolding, fixtures

and accessories for fixing relays, plug board, sting rods, fuses, mountings brackets, IDF,run way for cable/wires, frame,base assembly, insulators, J bolt, nut/bolts & fasteners etc.as per extent practice on Railway. Typical part list as per attached Annexure.

Engineer

b Supply of 200 Way Tag Block with cover as per IRS S77-91 - in quanitity 10 nos per Relayrack

RDSO

c Supply of Major Relay Group Base Plates, complete with fedlisters (20 No per base plate),guide rails and other accessories suitable for major group of Siemens type - in quanitity 01no per Relay rack

Engineer

d Supply of Relay base plate complete with amphanols, code pins, fixing screws etc.suitablefor Metal to Metal K-50 mini groups of Siemens type - in quanitity 40 no per Relay rack

Engineer

e Supply of Indoor Jumper Wire ATC 1 x 0.6 mm dia. PVC Insulated Single Core multistrandunsheathed with plain annealed copper conductor as per IRS:S-76/89 Amndt - 3 in variouscolours. The colour coding to be proposed by the contractor after observing the practicesof Railways - in quantity as per requirement of wiring of relays/relay groups & allassociated equipments and subsequent alteration to approved wiring diagrams

RDSO

Page 65: Bill of Quantities Pkg-2

f Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. PVC Insulated Single Core multistrandunsheathed with plain annealed copper conductor as per IRS:S-76/89 Amndt - 3 in variouscolours in coil length of 500 mtr. The colour coding to be proposed by the contractor afterobserving the practices of Railways - in quantity as per requirement of wiring ofrelays/relay groups & all associated equipments and subsequent alteration to approvedwiring diagrams.

RDSO

g Supply of Indicative type of Fuse holder of 0.6 A, 1.6 A and 6A along with fuses of System,Rapid or Malnad Make in Metal to Metal Installations - in quantity as per requirement forthe rack. This includes replacement of fuses blown off during testing and commissioning.

Engineer

h Supply of PVC Indoor Cable for packeting wiring 1x60x0.6mm dia., PVC Insulated MultiCore unsheathed with plain annealed copper conductor as per IRS:S-76/89 Amndt - 3Colour coding of insulation of inner core shall be in six colours viz. Blue, Red, Gray, Green,Brown and Black- in quantity as per requirement

RDSO

i Supply of PVC Indoor Cable for packeting wiring 1x 40x0.6mm dia. PVC Insulated MultiCore unsheathed with plain annealed copper conductor as per IRS:S-76/89 Amndt - 3Colour coding of insulation of inner core shall be in four colours viz. Yellow, White, Pinkand Violet - in quantity as per requirement

RDSO

j Supply of Flexible Wire Copper multistrand, 16 Sqmm, PVC insulated insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 1.21 ohms per Km at 20 degreeCentigrade; over all core diameter 8.45mm±0.25; conductor diameter: 0.400mm±0.005;Number of conductors:126 and test parameter as per specification no: IRS:S 76/89Amendt-3 for wiring from IPS to relay racks and power wiring in relay room in Red, Black,Green and Gray colours as per practice in railways - in quantity as per requirement.

RDSO

38455 This includes a Supply of Relay Rack Assembly (Q STYLE) complete with all scaffolding, fixtures and

accessories for fixing relays, plug board, sting rods, fuses, mountings brackets, run way forcable/wires,frame base assembly, insulators, J bolt, nut/bolts & fasteners etc. as perextent practice on Railway.

ENGINEER

Page 66: Bill of Quantities Pkg-2

b Supply of ladders for interconnecting relay racks as per extent practice on Railway - inquantity as per requirement.

ENGINEER

c Supply of Cable indoor copper conductor plain annealed high conductivity 650V gradePVC insulated unarmoured IRS-S-76/89 Amndt - 3. - 16 x 0.2 sq.mm in various colours.The colour coding to be proposed by the contractor after observing the practices ofRailways - in quantity as per requirement of wiring of all relays & all other associatedequipments and subsequent alteration to approved wiring diagrams.

RDSO

d Supply of Fuse block made of PBT as per IRS:S-75/2006 Rev 2 & drg.No. SA-23748.along with supply of Non deterioting type fuses as per IRS-S-78/92 to suit the basessupplied of Capacity as per requirement and wiring diagram - in quantity as perrequirement. This includes replacement of fuses blown off during testing andcommissioning. This also includes supply of negetive bus bar of copper as per requirement on fuse rack and practice of the Railway.

RDSO

e Supply of Flexible Wire Copper multistrand, 16 Sqmm, PVC insulated insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 1.21 ohms per Km at 20 degreeCentigrade; over all core diameter 8.45mm±0.25; conductor diameter: 0.400mm±0.005;Number of conductors:126 and test parameter as per specification no: IRS:S 76/89Amendt-3 for wiring from IPS room to relay racks and power wiring in relay room in Red,Black, Green and Gray colours as per practice in railways - in quantity as per requirementfor wiring between IPS to relay racks and between racks to racks and all other requirementas per Engineer.

RDSO

38456 Supply of Prewired crank handle cum key lock relay box along with LED, push button,terminal strip etc as per drg no.RVNL/S&T/SK/FIELD/11 suitable for 6 crank handle relayper box.

ENGINEER

DATALOGGER-SUPPLY

Page 67: Bill of Quantities Pkg-2

38501 Supply of Centralized Monitoring Data Logger at Control Office as per specification No:IRS: S- 99/2001 with latest amendments for centralized acquisition of data from individualremote EI's & RRI's. This includes supply of suitable front end processor, failure analysisand network management software, UPS, Printer, central monitoring unit etc. for on linemonitoring. The system should be compatible with the system in adjoining section.

RDSO

38502 This includesa Supply of Networked Data Logger for monitoring status of important relays, complete with

processor module to monitor 512 digital and 32 analog inputs as per spec. IRS:S-99/2006with Amndt-2 or latest including CMU, power supply of adequate capacity, battery,modems and fault diagonostic software for failure analysis, President rack of suitable size.

RDSO

b Supply of one no. composite computer-printer table,UPS and Printer and one no operatorchair.

RDSO

c In case of EI installation, this datalogger is for logging events outside of EI and full digitalinput must be supplied. Interface connection with EI is part of EI. The datalogger willtransfer its own data along with EI data to central monitoring unit.

RDSO

d Supply of Interconnecting cable between Contacts and Datalogger - this can be either60/40 indoor cable or jumper wires as per requirement

RDSO

e Supply of Interconnecting cable between CMU and Datalogger.38503 This includesa Supply of Networked Data Logger for monitoring status of important relays, complete with

processor module to monitor 1536 digital and 64 analog inputs as per spec. IRS:S-99/2006 with Amndt-2 or latest including CMU, power supply of adequate capacity, battery,modems and fault diagonostic software for failure analysis, President rack of suitable size.

RDSO

b Supply of one no. composite computer-printer table,UPS and Printer and one no operatorchair.

RDSO

Page 68: Bill of Quantities Pkg-2

c In case of EI installation, this datalogger is for logging events outside of EI and full digitalinput must be supplied. Interface connection with EI is part of EI. The datalogger willtransfer its own data along with EI data to central monitoring unit.

RDSO

d Supply of Interconnecting cable between Contacts and Datalogger - this can be either60/40 indoor cable or jumper wires as per requirement

RDSO

e Supply of Interconnecting cable between CMU and Datalogger.

38504 Supply of Remote Terminal Units (RTUs) in 64 Digital and 16 Analog inputs to be providedat LC Gates, Auto section Goomties, end Goomties of stations as per IRS :S-99/2006 orlatest having interface capabilities with Data logger at stations on both sides using theexisting VF channel. Supply of Interconnecting cable between Contacts and Datalogger -this can be either 60/40 indoor cable or jumper wires as per requirement

RDSO

BLOCK INSTRUMENT - SUPPLY38551 This includes supply of:a Supply of SGE type double line block instrument complete as per IRS S :-22/91 along with

bell unit - in quantity 01 no. RDSO

b Supply of Block bell equipment to Specification IRS (TC) 44/88. in quantity 01 no perblock instrument

RDSO

c Supply of Filter unit to Specification IRS(S) 68/89 - in quantity 01 no per block instrument RDSO

d Supply of DC polarized 3 position biased BPR relay IRS-S-31/80 amndt-1 - in quantity 01no per block instrument

RDSO

e Supply of Wooden block counter of size 700mm x 700mm W X 900mm H made of teakwood frame and 10mm/20mm thick water proof ply with Formica finish on top and all foursides having two compartment inside and two doors on opposite sides as per drg. NoRST/C/110 - in quantity 01 no per block instrument

ENGINEER

Page 69: Bill of Quantities Pkg-2

f Supply of VF Transformer of various types 470:470, 470:600, 470:1120, 600:1120:600:600, 1120:1120 etc. as per requirement - in quantity as per requirement.

ENGINEER

g Supply of Fuse block made of PBT as per IRS:S-75/2006 Rev 2 & drg.No. SA-23748.along with supply of Non deterioting type fuses as per IRS-S-78/92 to suit the basessupplied of Capacity as per requirement and wiring diagram - in quantity as perrequirement. This includes replacement of fuses blown off during testing andcommissioning.

RDSO

38552 This includes supply of:a Supply of Daido type single line token less block instruments complete with relays,

transmitter, receiver etc as per RDSO specn.no.S-98-2001.RDSO

b Supply of Filter unit to Specification IRS(S) 68/89 - in quantity 01 no per block instrument RDSO

c Supply of Wooden block counter of size 700mm x 700mm W X 900mm H made of teakwood frame and 10mm/20mm thick water proof ply with Formica finish on top and all foursides having two compartment inside and two doors on opposite sides as per drg. NoRST/C/110 - in quantity 01 no per block instrument

ENGINEER

d Supply of Fuse block made of PBT as per IRS:S-75/2006 Rev 2 & drg.No. SA-23748.along with supply of Non deterioting type fuses as per IRS-S-78/92 to suit the basessupplied of Capacity as per requirement and wiring diagram - in quantity as perrequirement. This includes replacement of fuses blown off during testing andcommissioning.

RDSO

38553 Supply of UFSBI (2 nos. as per RDSO/SPN/147/2005 with latest amendments), SM’sPanel for single line (2 nos as per RDSO/S/32019), block telephone & Relay Rack withdue locking & sealing arrangement completely wired fully with all relays required for Blockworking with Axle Counter & suitable for RE area as per RDSO Specn. No.RDSO/SPN/188/2004 with latest amendment.

RDSO

INTEGERATED POWER SUPPLY - SUPPLY

Page 70: Bill of Quantities Pkg-2

38601 Supply of Integrated Power (IPS) SMPS based as per RDSO specn. No. RDSO/SPN/165/2004 with Amendment 5 or latest. This shall be suitable for EI/PI in RE Area. Itincludes supply of 55 no. of low maintenence batteries of 300 AH, 2 volts each to RDSOspn.no.IRS:S-88/2004 with connector and cable and remote indication panel withadditional 5 nos spare batteries, wooden battery stand, hydrometer, RDSO prescribed toolkit and necessary spares. Before supplying the same the overall rating of the IPS systemshall be designed and worked out by the tenderer as per the yard requirements, Indoorload, distance of the gears at the site etc. The design then shall be got approved by theEngineer. The tentative capacity of the IPS shall be ( SMR - 20Amp - 5nos, Inverter & CVT- 2.5 KVA, TX-signal - 4 no, track circuit - 2 nos, lcgate - 1 no, DC-DC converter forInternal, External, Axle counter, Block line, Block tele, Block local, Panel indication, ICCetc.).

RDSO

38602 Supply of Integrated Power(IPS) SMPS based as per RDSO specn. No. RDSO/SPN/165/2004 with Amendment 5 or latest. This shall be suitable for Midsection LC gate/IBH/Auto section in RE Area. It includes supply of 55 no. of low maintenence batteries of120 AH, 2 volts each to RDSO spn.no.IRS:S-88/2004 with connector and cable andremote indication panel with additional 5 nos spare batteries, wooden battery stand,hydrometer, RDSO prescribed tool kit and necessary spares. Before supplying the samethe overall rating of the IPS system shall be designed and worked out by the tenderer asper the yard requirements, Indoor load, distance of the gears at the site etc. The designthen shall be got approved by the Engineer. The tentative capacity of the IPS shall be (SMR - 20Amp - 3nos, Inverter & CVT - 1 KVA, TX-signal - 3 no, track circuit - 1 nos, lcgate- 1 no, DC-DC converter for Internal, External, panel indication, Hooter, gate telephoneICC etc.).

RDSO

Page 71: Bill of Quantities Pkg-2

38603 Supply of Single Phase Air Cooled, Silent DG set ( CPCB approved acoustic enclosure)with alternator of 10 KVA, 0.8 PF and engine of minimum 16 BHP (multi cylinder) floormounting type for installation in open complete with electrical control panel containingammeter, voltmeter indicators, MCB/MCCB and key start/stop assembly, low maintenancebattery of 12V-80AH as per IRS S-88/2004 of Standard/Exide/Amco type, battery chargerfor charging the battery. It also include provision of diesel tank of sutiable capacity to runminimum 10 hours fitted with a cock, supply pipe arrangement & its fixtures, clamps etc.for supplying diesel oil to the Diesel Engine from this tank. The engine ratings are as perIS 10001, BS 5514, DIN 6271, ISO 3046 standars. The DG set ratings are as per ISO8528 standards and are continuous ratings at STP conditions with 10% overload for 1 hourduring 12 hours continuous running.

RITES

38604 Supply of Single Phase Air Cooled, Silent DG set ( CPCB approved acoustic enclosure)with alternator of 15 KVA, 0.8 PF and engine of minimum 25 BHP (multi cylinder) floormounting type for installation in open complete with electrical control panel containingammeter, voltmeter indicators, MCB/MCCB and key start/stop assembly, low maintenancebattery of 12V-80AH as per IRS S-88/2004 of Standard/Exide/Amco type, battery chargerfor charging the battery. It also include provision of diesel tank of sutiable capacity to runminimum 10 hours fitted with a cock, supply pipe arrangement & its fixtures, clamps etc.for supplying diesel oil to the Diesel Engine from this tank. The engine ratings are as perIS 10001, BS 5514, DIN 6271, ISO 3046 standars. The DG set ratings are as per ISO8528 standards and are continuous ratings at STP conditions with 10% overload for 1 hourduring 12 hours continuous running.

RITES

OUTDOOR CABLES - SUPPLY38651 Supply of Railway underground jelly filled , 0.9 mm dia, 6 Quad cable as per spec. No.

TC/30/2005 Amndt-2 or latest. RDSO

38652 Supply of PIJF-Polythene insulated polythene sheathed jelly filled telephone cable withpoly-AL moisture barrier with armoured of size: 05 PAIR X 0.63 MM. as per specificationIRS:TC-41/97 amendment no. 1 or latest

RDSO

Page 72: Bill of Quantities Pkg-2

38653 Supply of PIJF-Polythene insulated polythene sheathed jelly filled telephone cable withpoly-AL moisture barrier with armoured of size: 10 PAIR X 0.63 MM. as per specificationIRS:TC-41/97 amendment no. 1 or latest

RDSO

38654 Supply of PIJF-Polythene insulated polythene sheathed jelly filled telephone cable withpoly-AL moisture barrier with armoured of size: 20 PAIR X 0.63 MM. as per specificationIRS:TC-41/97 amendment no. 1 or latest

RDSO

38655 Supply of PIJF-Polythene insulated polythene sheathed jelly filled telephone cable withpoly-AL moisture barrier with armoured of size: 50 PAIR X 0.63 MM. as per specificationIRS:TC-41/97 amendment no. 1 or latest

RDSO

38656 Supply of PIJF-Polythene insulated polythene sheathed jelly filled telephone cable withpoly-AL moisture barrier with armoured of size: 50 PAIR X 0.9 MM. as per specificationIRS:TC-41/97 amendment no. 1 or latest

RDSO

38657 Supply of 24 fibre armoured optic fibre cable as per specification no.IRS.TC.55/2006Rev.1 with Amdt.1.1 or latest.

RDSO

CABLE PROTECTION WORK - SUPPLY38701 Supply of RCC pipes 150mm dia, 2 Mtr long along with collars as per Specn. No.

IS/458/1971 for use near OHE Substation for cable protection.ENGINEER

38702 Supply of DWC pipe with one snap fit coupler and 'O' ring conforming to IS 14930 (part 2 :2001), Non metallic, corrugated, multiwalled, normal duty, pliable, without protectionagainst chemical attack and Non flame propagating in 6 meter length of size 120 mm outerdia & 102 mm inner dia.( Permitted tolerance in dia = +/- 2 mm).

RITES

38703 Supply of SPLIT DWC pipe conforming to IS 14930 (part 2 : 2001), Non metallic,corrugated, multiwalled, normal duty, pliable, without protection against chemical attackand Non flame propagating in 2 meter length of size 200 mm outer dia & 175 mm innerdia.( Permitted tolerance in dia = +/-2 mm) ( TWO half round pipe constitute one split pipe)

RITES

Page 73: Bill of Quantities Pkg-2

38704 Supply of Galvanized Iron pipe 100 mm dia medium grade with screw end both side andfitted with sockets as per specn. No.IS-1239, part 1 / 1990 in length of approx 6 meters

RITES

38705 This includes:a Supply of theromoshrinkable jointing kits as per RDSO Spec. No. IRS. TC77-2000/Amdt.1

( or latest) suitable for 6 quad cableRDSO

b Supply of 2T type small VF transformer (470:1120) for quad derivation joints suitable for 6quad cable - required only for derivation joints.

ENGINEER

c Making of Joint on Quad cable as Straight through joint with out transformer or derivationjoint with 2T Transformer as directed by engineer at site.The derivation joint includestapping of nominated quad of 6 quad cable at specific location to 10 pair PIJF cablealready laid in the ground. This also includes supply of all other materials required for thework. After jointing the cable thorough test such as insulation test, continuity test etc., to becarried out jointly with Engineer and in case of defective joints, same will be rejected alongwith jointing material.

ENGINEER

COLOUR LIGHT SIGNALS - SUPPLY38751 Supply of Colour light signal (2 aspect) as per drg.No.SA - 23003 A/M (adv.) alt.8 & Specn.

IRS-S-23/86 & 26/64 having following items (a)Signal post 140 mm dia 4.5 / 3.5 mtrs. Longto IRS-s-6-81. (b) Signal base C I 140 mm dia. to drg. No.S-2011. (c) CLS ladder completewith platform and Signal front staging as per Drg, base 4.5 / 3.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1. (d)CLS unit 2 aspect complete to drg.No SA – 23003 A/M to C/M (Adv.)without transformer & lenses. (e)4 nos of Anchor bolt complete with nut washer etc as perDrg (f) Supply of Universal lock with key (hand cuff) - 1 no

RITES

Page 74: Bill of Quantities Pkg-2

38752 Supply of Colour light signal (3/4 aspect) as per drg.No.SA23002 A/M (adv.) alt.8 & Specn.IRS-S-23/86 & 26/64 having following items :(a) Signal post 140 mm dia 4.5 /3.5mtrs. longto IRS-S-6-81. (b)Signal base C I 140 mm dia. to drg. No.S-2011. (c) CLS laddercomplete with platform and signal front staging as per Drg , base 4.5 / 3.5 mtrs. long todrg.No.SA-23153 (Adv.) Alt 1. (d)CLS unit 3/4 aspect complete to drg.No.SA – 23002 A/Mto C/M (Adv.) without transformer & lenses. (e)4 nos of Anchor bolt complete with nutwasher etc as per Drg (f) Supply of Universal lock with key (hand cuff)

RITES

38753 This includes:a Supply of Junction type route indicator (1 way) along with out lamp holder unit, lens,&

lamps to IRS-S-66/84, Amndt-1 or latest, IRS-S-23/86 with drg.No. SA-23401 (adv.) alt2.suitable for LED lamps.

RITES

b Supply of OFF set bracket of main signal for 140mm dia drg no.SA-23080 (Adv) Alt.1 IRS-S-10-78 along with U Clamp and nuts. - 1 no

RITES

c Supply of Universal lock with key (hand cuff) - 1 no RITES38754 This includes:a Supply of Junction type route indicator (2 way) without lamp holder unit, lenses & lamps to

IRS-S -66/84, Amndt-1 or latest, IRS-S-23/86 with RDSO drg.No.SA-23402 (adv.) alt2.suitable for LED lamps

RITES

b Supply of OFF set bracket of main signal for 140mm dia drg no.SA-23080 (Adv) Alt.1 IRS-S-10-78 along with U Clamp and nuts.

RITES

c Supply of Universal lock with key (hand cuff) RITES38755 This includes:a Supply of Junction type route indicator (3 way) without lamp holder unit, lenses & lamps to

IRS-S -66/84, Amndt-1 or latest, IRS-S-23/86 with RDSO drg.No.SA-23403 (adv.) alt2.suitable for LED lamps

RITES

Page 75: Bill of Quantities Pkg-2

b Supply of OFF set bracket of main signal for 140mm dia drg no.SA-23080 (Adv) Alt.1 IRS-S-10-78 along with U Clamp and nuts.

RITES

c Supply of Universal lock with key (hand cuff) RITES38756 Supply of Independent shunt signals complete having following items. (a) Shunt signal

post 90 mm dia 1m long to IRS-S-6/81 (b) Shunt signal surface base 90 mm dia drg.No. S-2011 (c ) Position light shunt signal unit without lenses, LED unit to RDSO drg.No.SA-23840 (Adv) (d)4 nos. Anchor bolts complete (305 mm x 50mm x 20mm) to drg. No.SA-110A/M (f) Supply of Universal lock with key (hand cuff)

RITES

38757 Supply of Dependant type Position light shunt signal unit without lenses, LED unit drg no.SA-23840 (Adv) Alt.1 & S-23845 (Adv)

RITES

b Supply of OFF set bracket of shunt signal for 90mm dia along with U Clamp and nuts. RITES

c Supply of Universal lock with key (hand cuff) RITES38758 Supply of Calling on signal unit suitable for LED lamp as per RDSO drg.No.S-23463 &

fixing arrangement having RDSO drg.No.SA-24351 (adv.) alt.1. RITES

38759 Supply of AC LIT LED signal lighting unit for main signal as per RDSO/SPN/153/2004 Rev3 or latest. This shall also include current regulator, health monitor & alarm unit. Signalshall be suitable to CLS as per RDSO drawing no. SA-23002 and as 23024/M with latestamendment - The colour of aspect to be decided based on the Signalling Plan and as perrequirement.

RDSO

38760 Supply of AC 110 V LIT LED signal lighting unit as per RDSO Spn no:RDSO/Spn/153/2004 rev 3 or latest for junction type route indicator/ shunt/ calling-on.

RDSO

DC TRACK CIRCUIT - SUPPLY38801 This includes:

Page 76: Bill of Quantities Pkg-2

a Supply of Track feed battery charger 110V AC/6 V DC - suitable to charge 3 cells of 80AH, to IRS-S-89/93 amndt-2 or latest. - 1 no

RDSO

b Supply of `B' type choke as per specification No.IRS-S-65/83 amndt-1 or latest. - as perrequirement - Nil in Non RE Area, One in AC RE Area, Two as per Railway Practice

RDSO

c Supply of adjustable Track Feed Resistance (Disc type) 30 ohms as per RDSO Drg. No.SA 20166/M (Adv) with latest amendments (with Phenolic moulded base). - 1 no

RDSO

d Supply of Relay DC track plug in type neutral, 9 ohms, tractive armature 2 F/1B with frontcontacts metal to carbon (QT2 type in Non RE and QTA 2 type in RE area) complete withplug board, retaining clip and connector to BRS-939A, and BRS-966(appendix F-2), IRS-S-34/68 & IRS-S-23/86. Interlocking code F,G,H,K,X. - 1 no

RDSO

e Supply of Relay DC plug in neutral line slow to pickup tractive armature 24 VDC 8F/ 4Bcontacts, front & back contacts metal to carbon complete with plug board, retaining clips &connectors etc. to BRS-933/933A, IRS-S-34/68, IRS-S-23/86 & IRS-S-60 similar to QSPA1 interlocking code ABDEJ -1 no

RDSO

f Supply of Fuse block made of PBT as per IRS:S-75/2006 Rev 2 & drg.No. SA-23748.along with supply of Non deterioting type fuses as per IRS-S-78/92 to suit the basessupplied of Capacity as per requirement and wiring diagram - in quantity as perrequirement. This includes replacement of fuses blown off during testing andcommissioning.

RDSO

g Supply of Lead acid low maintenance secondary cells of 2V/ 80 AH along with connectinglinks, floats & insulators as per RDSO specification No.IRS-S-88/2004 - 3 no. of batteriesper track Circuit

RDSO

ELCTRIC POINT MACHINE - SUPPLY38811 This includes:

Page 77: Bill of Quantities Pkg-2

a Supply of Electrical point operating machine - IRS Type, 220 mm throw (AC immunity 160V AC), non trailable to operate on 110 V DC with lock & detector slides, Cable terminal boxand Clamp lock arrangement for thick web switches (Drg no. RDSO:S-3395 & S-3454)confirming to IRS:S-24/2002, Drg no: S-11000 & for Motor IRS: S37/82.

RDSO

b Supply of Ground Connections for thick web switches - 1 complete set per point machine RITES

38812 This includes:a Supply of Electrical point operating machine - IRS Type,143 mm throw (AC immunity 160

V AC), non trailable to operate on 110 V DC with lock & detector slides, Cable terminal boxconfirming to IRS:S-24/2002 & for Motor IRS: S37/82, Assy Drg RDSO-S:10800 &S:10910

RDSO

b Supply of Ground connection for 143 mm throw IRS type machine complete (5 rods) asper drg no. (I) SA 8805 (II) RDSO/S/3273 (III) RDSO/S/3271 (IV) RDSO/S/3267 (V)RDSO/S/3269, switch extension bracket RDSO/S/3264 & drive lug S 8806. - 1 completeset per point machine

RITES

LOCATION BOX WORK - SUPPLY38821 This includes:a Supply of Location box made of 10 SWG (3.2mm) sheet complete with `E' type lock &

keys , 1key for every five apparatus cases to be supplied. (Full Location ) as per drg withAdditional (i) fixed handle on door (ii) Provision for external padlock arrangement.(iii)Suitable arrangement for holding the door at 90º in its open condition.

RITES

b Supply of Hylam sheet (Bakelite industrial laminated paper based sheet), resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 mtrs. as per specn. No. IS 2036 of1974. -as per requirement for termination of cables and for shelf for fixing equipments

RITES

Page 78: Bill of Quantities Pkg-2

c Supply of Universal lock with key (hand cuff) - 2 no RITES

38822 This includes:a Supply of Location box made of 10 SWG (3.2mm) sheet complete with `E' type lock &

keys , 1key for every five apparatus cases to be supplied. (Half Location ) as per drg withAdditional (i) fixed handle on door (ii) Provision for external padlock arrangement.(iii)Suitable arrangement for holding the door at 90º in its open condition.

RITES

b Supply of Hylam sheet (Bakelite industrial laminated paper based sheet), resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 mtrs. as per specn. No. IS 2036 of1974. -as per requirement for termination of cables and for shelf for fixing equipments

RITES

c Supply of Universal lock with key (hand cuff) - 2 no RITES

38823 Supply of ARA Terminal blocks with links, 6 Way, made of PBT Specn No.IRS/75/2006(Amd - 2) and RDSO Drg.No.SA-23756 Alt.3.

RDSO

38824 MODULAR TERMINALS: Supply of 4-conductor disconnect terminal block with test &measurement facility, with screw clamp/screwless cage clamp connections suitable for 1.5to 2.5 sq. mm conductor with current carrying capacity of 16Amp as per RDSO Specn. no.RDSO/SPN/189/2004 of WAGO/PHOENIX type.This also include Supply of requiredquantity of (i) End Plate (ii) Din Rail (iii) End Stop (iv) Marker & operating tool. End Plate,DIN rail, End stop and marker to be supplied only in the required quantity for abovementioned MODULAR terminals. All samples to be approved by engineer in charge beforeplacing order on vendor.

ENGINEER

LEVEL CROSSING GATE - SUPPLY38851 This includes:

Page 79: Bill of Quantities Pkg-2

a Supply of Electrically operated lifting barrier assembly each consisting of 2 Nos. ofelectrically operated lifting barriers complete with all accessories as per IRS-S-41/70 (Amd-2). Aluminum boom in 4 section of 8 feet long each along with Gate control panel &indication panel on sheet metal fabricated box , supply of power contactors, flasher relaysetc.

RDSO

b Dual tone warning bell (hooter) with 20 Watt Horn and 15 Watt amplifier MUCONY TYPEor similar with operating voltage 110 V A/C - 1 set

ENGINEER

38852 This includes:a Supply of Lifting barrier Gate complete (Fracture segements)with 10 Meters long boom

with winch, boom locking arrangement, interlocking frame ground type - two lever,pedestals, stop boards, boom light boxes, CI counter weights, boom supports, gate lamps,bells, insulated rod joints butt end, insulation material, screw joints, Foundation type-A,wire rope (7X7X19), circuit controller, pulley stake complete with 2 way pulley assembly,horizontal rope wheel -2way, vertical rope wheel, rubber insulator, wire adjusting screw12m long range, E type lock and all associated accessories as per RDSO Drg No.

RITES

REFERENCE RDSO DRG NO. for above items are: SA-8835 ALT-1, SA-8132A ALT-1, SA-923/M ALT-1, SA-922/M ALT-1, SA(325,326,327)/M ALT-1, SA-3622/M, S-3529/M, S-3065/M, S-3054/M, SA-3051/M, SA-3001/M, SA-3005/M, SA-3008/M, SA-3009/M, SA-6065/M as per IRS: S-10/78 & IRS:S28

b Dual tone warning bell (hooter) with 20 Watt Horn and 15 Watt amplifier MUCONY TYPEor similar with operating voltage 110 V A/C - 1 set

ENGINEER

MISCELLANEOUS WORK - SUPPLY38901 This includes:a Office chairs of model no CH-1007 of Godrej or equivalent model of same make. - 2 no ENGINEER

Page 80: Bill of Quantities Pkg-2

b Office tables of model no T9 of Godrej or equivalent model of same make. with 3 drawerson left hand side & one locker on the right hand side. Olive brown/green with duplicatekeys. -1 no

ENGINEER

c Airy revolving & tilting working cushion chair with arm rests of model no PCH 7002 ofGodrej make or equivalent of same make. -1 no

ENGINEER

d Supply of steel almirah - office storwel of Godrej make or equivalent model of same make.Size 1980 x 915 x 486 approx with 4 shelves making 5 compartments without lockerhaving locking door. -1 no

ENGINEER

e Steel stool Godrej make or similar ST-2 or equivalent -4 no. ENGINEER

38921 Supply of Electronic magneto telephone desk type as per specn.No.IRS :TC79/2000.withlatest amendment

ENGINEER

38922 Supply of Various types of markers as:-P/C/G/A/IB markers -23 cm. Dia circular disc madeof 3mm thick MS Sheet. The disc shall be painted with approved colour scheme.

RITES

38923 Supply of Tools for testing - Digital multimeter of fluke make- 1no, Digital Clamp type AC &DC Ampere Meter - Fluke make- 1no.

ENGINEER

38924 Supply of Maintenance tool kit complete as per list attached. ENGINEER

ELCTRONIC INTERLOCKING WORK- EXECUTION39001 This includes :a Supply of Documents/Manuals for EI System as per para 10.1 of RDSO Specification

No:RDSO/SPN/192/2005 ENGINEER

b Earthing of EI Equipment, Relay Racks and Power Equipment etc. to be done along withsupply of all requisite materials as per EI requirement, RDSO directives and SignalEngineering Practice for lightening protection.

RDSO

Page 81: Bill of Quantities Pkg-2

c Supply of Flexible Wire Copper multistrand, 16 Sqmm, PVC insulated insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 1.21 ohms per Km at 20 degreeCentigrade; over all core diameter 8.45mm±0.25; conductor diameter: 0.400mm±0.005;Number of conductors:126 and test parameter as per specification no: IRS:S 76/89Amendt-3 for wiring from IPS room to EI room and power wiring as per site requirement.

RDSO

d Installation, Wiring, testing, Soldering of all EI equipments with contractor's materialincluding wiring & soldering of panel, relays, Gumties (where ever provided) and bringingthe functions up to CT Rack in same room.

ENGINEER

e Supply of all related consumable materials like rosin core, lacing thread, PVC bunchingtape and buttons eyelets of sizes,.etc.

ENGINEER

f Power wiring of all EI equipments, laying of power cable from IPS room to EI room and toall other associated functions like panel processors, interface relay racks, datalogger,maintenance terminals etc.

ENGINEER

g Contractor's Testing and organising testing for RVNL/Railway. The testing includes -Functional testing, selection table testing with contractor's simulation panel.

ENGINEER

39002 Training (at site and/or works) is to be organised for two types of modules: Module (1) isfor Field Technicians & Engineers & Module (2) is for Engineers and Officers ofRVNL/Railway. The training module covers Installation, Commissioning, testing andmaintenance and include supply of hard copies of course modules

39003 Commissioning of Electronic Interlocking system after interfacing of indoor equipmentswith outdoor gears in association with Railway Personnel during Non Interlock working.Competent Engineer of manufacturer must be available during Pre NI, NI and Post NI.

ENGINEER

AXLE COUNTER WORK - EXECUTION

Page 82: Bill of Quantities Pkg-2

39101 Installation, wiring, testing & commissioning of new Digital axle counter system. Outdoorwork includes : Fixing of track transducers on the rails. Drilling of holes in rails. supply andlaing of HDPE pipe, Laying of track transducers cable from rail to EJB in HDPE pipe andfrom EJB to Location box by digging/trenching as per instruction of Site Engineer.Installation of electronic junction box in location box. Termination of cables & wiring ofEJB. Indoor work includes: Installation of Evaluator, wiring and termination of quad cable.Laying & termination of cable from C.T.rack to evaluator. Fixing of relays, bus bars &fuses.Installation, wiring, testing & commissioning of reset box & line verification box in SMroom / cabin. This includes: Fixing of reset box/line verification box on Wooden/hylamsheet. Supply & fixing of MS angles. RDSO Check list for installation are to be complied bymanufacturer's engineer.

ENGINEER

39102 Shifting & adjustment of existing Multi section digital axle counters - Decommissioning andShifting of EJB, Evaluators,reset box, LV box and Refixing of these equipments along withfixing of existing/new TX / RX coils at new locations where ever required in HDPE pipealong with supply of HDPE pipe. Rewiring of above equipments, reprogramming of digitalaxle counter, power wiring, testing and commissioning the same as directed by siteEngineer. If required Engineer from manufacturer need be called.

ENGINEER

39103 Shifting & adjustment of existing analog axle counters/SSDAC - Decommissioning andShifting of EJB, Evaluators,reset box, LV box and Refixing of these equipments along withfixing of existing/new TX / RX coils at new locations where ever required in HDPE pipealong with supply of HDPE pipe.. Rewiring of above equipments, power wiring, testing andcommissioning the same as directed by site Engineer.

ENGINEER

DESIGN AND DRAWING WORK - EXECUTION

Page 83: Bill of Quantities Pkg-2

39301 DESIGN OF SIGNAL INTERLOCKING PLAN: Designing of signaling arrangements basedon approved ESP as per practice of Railway. This includes correction at various stages asper requirement of RVNL /Railway. Plotting of designed Interlocking Plan(IP) inAUTOCAD. Correction as per requirement. Submission of as required white prints of IP asper scale being followed by Railway. Submission of tracing of Final approved SIP on90gsm tracing paper.

ENGINEER

39302 to 39305

Following description remains common for all the items covered in item no 39302 to39305. This include:

a DESIGN & DRAWING : Design Includes all gears of the station like Block, panel, LC gate,ICC, etc as indicated in Signal Interlocking Plan- INDOOR: Design, preparation & supply ofprints in Auto CAD format of various documents /diagrams /sketches listed below in A3size for stations. The Contractor shall initially supply 2 sets of complete documents/circuitsduly signed by the designer for approval of Railways. Designer has to coordinate withApproving authority to understand the local Railway's practice and carry out modificationsaccordingly. Railways will return one set of documents/circuits to the contractor dulyapproved with alteration/corrections if any. The contractor shall incorporate Railwaysalterations/corrections in the original tracing & CD without any deviation and submit 3prints of complete document/circuits.

ENGINEER

b The work shall be executed only as per approved final documents/circuits. Aftercompletion of work the contractor shall submit Completion tracings modified as percompleted work, After approval of tracings, final completion CD complete in all respectalong with 6 sets of prints of completion documents/ circuits along with approved tracingsshall be submitted. The papers used for tracing and prints should be of superior quality.Transparent polythene covers duly covering each sheet of one set of print out of 6 sets ofprints of completion documents/circuits shall be supplied.

ENGINEER

c Note: The Size of SIP, Front Plate Diagram and Route section diagram may be in differentsizes as per the requirement and practices of the Railway.

Page 84: Bill of Quantities Pkg-2

d INDOOR DRAWINGS: List of Documents (Only the required drawings):- Front PanelDiagram, Route section diagram, Locking Table, Station Working Rule Diagram, Contactanalysis, Application Programme listing/Wiring Diagram, Input/Output chart along with alllogic details with proper contact analysis, Record of one wire/two wire termination on tagblock, Power Supply, Equipment layout particulars in Relay room and Equipment rooms,Relay disposition diagram in Relay room, CT rack details, Completion documents like I.P.,LT etc.

ENGINEER

39302 Design and drawing for complete indoor signalling work for new PI/EI/RRI station, as perpractice in Railway.

ENGINEER

39303 Design and drawing for complete indoor signalling work associated with modification in aPI/EI/RRI station, due to work of doubling or third line or junction arrangement or due to 25KV Railway Electrification etc.

ENGINEER

39304 Design and drawing for complete indoor signalling work for IBH / Midsection interlocked LCgate/ C class station/ One Auto Section etc.

ENGINEER

39305 PHASE DRAWINGS: Designing the modification to existing approved SIP, LT, PD, SWRand logic and wiring in EI OR wiring circuits in PI to suit proposed Yard Layout inconnection with phase working while extending doubling / Third line as per workrequirement. NOTE: This item to be operated while commissioning of doubling/ third line atone end of the yard and other end will remain as existing single/double line/ third line tofacilitate development of phase drawings and phase commissioning.

ENGINEER

39306 This includes:a Preparation of Station Working Rules as practice in Railways including Gate working rules

and appendix (in multiple language wherever required) and its subsequent corrections. 10copies of Station Working Rules to be given along with the soft copies.

ENGINEER

Page 85: Bill of Quantities Pkg-2

b Preparation of CRS Papers along with Descriptive note, list of infringements from scheduleof dimensions, list of deviations from G&SR, dispensation and condonation statement etc.as per practice in railways, obtaining signature of the authorities and submission to CRS.RVNL and PMC will assist in checking and obtaining signature and sanction from CRS.The Payment will be made for each application for Sanction submitted to CRS. Applicationfor dispensation is part of CRS Application of yard.

ENGINEER

39307 to 39309

Following description remains common for all the items covered in item no 39307 to39309. This include:

a DESIGN & DRAWING:Design Includes all gears of the station like Block, panel, LC gate,ICC, etc as indicated in Signal Interlocking Plan- OUTDOOR: Design, preparation & supplyof prints in Auto CAD format of various documents /diagrams /sketches listed below inrequired size. The Contractor shall initially supply 2 sets of complete documents/circuitsduly signed by the designer for approval of RVNL/Railways. Designer has to coordinatewith Approving authority to understand the local Railway's philosophy and carry outmodifications accordingly. They will return one set of documents to the contractor dulyapproved with alteration/corrections if any. The contractor shall incorporate thesealterations/corrections in the original tracing & CD without any deviation and submit 3prints of complete document/circuits.

ENGINEER

b The work shall be executed only as per approved final documents. After completion ofwork the contractor shall submit Completion tracings modified as per completed work andapproval of tracings & then submission of final completion CD complete in all respectalong with 6 sets of prints of completion documents/ circuits along with approved tracings.The papers used for tracing and prints should be of superior quality.

ENGINEER

c OUTDOOR DRAWINGS: (Only required Drawings)- Cable route plan, Cable Coreageplan, Track Circuit bonding plan, Location box details plan, Junction box details, trackcircuit wiring arrangement, point machine wiring etc.. Any other drgs required by Engineerincharge.

ENGINEER

Page 86: Bill of Quantities Pkg-2

39307 Design and drawing for complete Outdoor signalling work for new PI/EI/RRI station, as perpractice in Railway.

ENGINEER

39308 Design and drawing for complete Outdoor signalling work associated with modification in aPI/EI/RRI station, due to work of doubling or third line or junction arrangement or due to 25KV Railway Electrification etc.

ENGINEER

39309 Design and drawing for complete Outdoor signalling work for IBH / Midsection interlockedLC gate/ C class station/ One Auto Section etc.

ENGINEER

INDOOR PI/RRI WORK - EXECUTION39451 This includes:a Installation, complete wiring, testing and commissioning of LED type Control cum

indication panel. This includes wiring & termination of indoor cables coming from relayroom on panel tag blocks as per Panel Tag Block Analysis and instructions of Engineer.The wiring on panel tag blocks may be required to be repeated on tag blocks in relayroom. If there is no common wall between panel & relay room the indoor cable can be laidin GI pipe as per instructions of Engineer at site. This covers supply of all materialrequired. During testing fused LEDs are to be replaced immediately. After commissioningof Panel, cementing and plastering of panel base along with foundation/grouting etc.

ENGINEER

b Manufacture, supply, transportation & installation of station masters console for fixingtelephones & other equipment. This includes supply of all materials like MS angles, MSflat, plywood, hylum, sunmica etc. required for the above including sundry items like bolts& nuts, screws. This design shall be developed by contractor in consultation with siteengineer.

ENGINEER

39452 This includes:a Erection & Installation of Cable Termination Rack Assembly complete with wall supports,

scaffolding, 8 way/ ARA/Modular terminal, 96 way tag-block and other necessaryaccessories etc. The work shall be done as per approved plan, extent practice on Rly. andthe instructions of Railway Engineer at site.

ENGINEER

Page 87: Bill of Quantities Pkg-2

b Termination of cable core in CT rack at 8Way/ARA/Modular terminal. This includes pullingout of cable from under ground, spilling of cable & fixing on the CT rack etc. andsubmission of cable termination particulars.

ENGINEER

c Laying of indoor signalling cable on ladder, dressing, and terminating the same on Old andNew CT rack, wherever required, to patch the Old Outdoor signalling cable in newinstallation.

ENGINEER

39453 Installation of complete Relay Rack Assembly (Siemens style or Q-style) with wall support,Scaffolding, Ladders, Run way for cables, Fixing of Relay bases/ Relay group base plates,Tag blocks, fixing of ladder, relay plug boards, terminal, blocks. Laying, lacing, dressingand packeting of indoor cable/ flexible wire and soldering, Fuse block fixing, fuse wiring,function wiring, (interconnection between relay rack and CT rack). The work shall be doneas per approved plan, extent practice on Rly and the instructions of Engineer at site. Thisincludes supply of all nuts, bolts, MS clamps & cement for masonry works, lacing thread,PVC tape, solder rosin core etc.

ENGINEER

39454 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing. Wiring of block instrument withaccessories,data logger, power equipment, operating panel, key lock, test board etc., fuseboard etc. Contractor's Testing and organising testing for RVNL & Railway -Functionaltesting, selection table testing with contractor's simulation panel. This includes supply of allrelated consumable materials like rosin core, lacing thread, PVC bunching tape andbuttons eyelets of sizes,Resistance, condensor, diodes, LED's etc as per the requirementof wiring diagrams. After completion of entire signalling and civil work, one round of acrlylicsynthetic paint to be provided inside of Relay room and IPS room, whereever new roomsare constructed - FOR NEW PI/RRI STATIONS- UP TO 50 ROUTES

ENGINEER

Page 88: Bill of Quantities Pkg-2

39455 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing. Wiring of block instrument withaccessories,data logger, power equipment, operating panel, key lock, test board etc., fuseboard etc. Contractor's Testing and organising testing for RVNL & Railway -Functionaltesting, selection table testing with contractor's simulation panel. This includes supply of allrelated consumable materials like rosin core, lacing thread, PVC bunching tape andbuttons eyelets of sizes,Resistance, condensor, diodes, LED's etc as per the requirementof wiring diagrams. After completion of entire signalling and civil work, one round of acrlylicsynthetic paint to be provided inside of Relay room and IPS room, whereever new roomsare constructed -FOR NEW PI/RRI STATIONS- ABOVE 50 ROUTES

ENGINEER

39456 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing. Wiring of block instrument withaccessories,data logger, power equipment, operating panel modification, key lock, testboard etc., fuse board etc. Contractor's Testing and organising testing for RVNL & Railway-Functional testing, selection table testing with contractor's simulation panel. This includessupply of all related consumable materials like rosin core, lacing thread, PVC bunchingtape and buttons eyelets of sizes,Resistance, condensor, diodes, LED's etc as per therequirement of wiring diagrams - RELATED WITH MODIFICATION IN EXISTINGPI/EI/RRI STATIONS/Cabins OF UPTO 50 ROUTES as per Signal Interlocking plan forconnecting double line/third line or due to 25 KV Railway electrifcation.

ENGINEER

Page 89: Bill of Quantities Pkg-2

39457 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing. Wiring of block instrument withaccessories,data logger, power equipment, operating panel modification, key lock, testboard etc., fuse board etc. Contractor's Testing and organising testing for RVNL & Railway-Functional testing, selection table testing with contractor's simulation panel. This includessupply of all related consumable materials like rosin core, lacing thread, PVC bunchingtape and buttons eyelets of sizes,Resistance, condensor, diodes, LED's etc as per therequirement of wiring diagrams. RELATED WITHMODIFICATION IN EXISTING PI/EI/RRISTATIONS/Cabins OF ABOVE 50 ROUTES as per Signal Interlocking plan for doubling /third line/ yard remodelling or due to 25 KV Railway electrifcation

ENGINEER

39458 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing. Wiring of block instrument withaccessories,data logger, power equipment, operating panel, key lock, test board etc., fuseboard etc. Contractor's Testing and organising testing for RVNL & Railway -Functionaltesting, selection table testing with contractor's simulation panel. This includes supply of allrelated consumable materials like rosin core, lacing thread, PVC bunching tape andbuttons eyelets of sizes,Resistance, condensor, diodes, LED's etc as per the requirementof wiring diagrams. After completion of entire signalling and civil work, one round of acrlylicsynthetic paint to be provided inside of Relay room and IPS room, whereever new roomsare constructed - FOR ONE IBH / ONE MIDSECTION LC GATE / C CLASS STN/AUTOSECTION. Wiring at IBH/Auto/LC Gate includes associated signaling modification atstations/cabins/gates at either end. NOTE: The wiring may be required to be done much inadvance of commissioning and make it functional for existing line, and subsequentmodifications may be required to be done while commissioning new line.

ENGINEER

Page 90: Bill of Quantities Pkg-2

39459 Complete Indoor work of installation, wiring and commissioning. This includes wiring ofrelay base plate to other base plate, to IDF, to tag block,wiring of circuits as per approveddiagram, jumpering and soldering after testing, power equipment, operating panel, keylock, test board etc., fuse board etc. Contractor's Testing and organising testing for RVNL& Railway -Functional testing, selection table testing with contractor's simulation panel.This includes supply of all related consumable materials like rosin core, lacing thread, PVCbunching tape and buttons eyelets of sizes,Resistance, condensor, diodes, LED's etc asper the requirement of wiring diagrams - FOR ONE TRAFFIC INTERLOCKED GATEwithout independent signals.

ENGINEER

39460 PHASE WORKING: Complete Indoor work of Alteration to existing circuit OR Modificationto existing Logic and Wiring in EI. This includes Wiring of relay base plate to other baseplate, to IDF, to tag block, jumpering, function wiring up to CT rack, fixing of Relays, Wiringof Fuse, power equipment, block instrument, operating panel, keylock, testboard etc.,fixing of ladder, relay plug boards, terminal, blocks, terminals fuse board, fuses bus bar,lacing of wires, fixing of eyelet, modification in operating cum indication panel to suit yardlayout etc. as per approved diagram or Logic , testing & soldering after testing.Contractor's Testing and organising testing for RVNL&Railway -Functional testing,selection table testing with contractor's simulation panel. This includes supply of all relatedconsumable materials like rosin core, lacing thread, PVC bunching tape and buttonseyelets of sizes,Resistance, condensor, diodes, LED's etc as per the existing arrangementin Relay rooms in connection with (a) modification from Double Line to Third Line relatedwith extn of third line. OR (b) modification from Single Line to Double Line related with extnof Doubling.

ENGINEER

39461 Fabrication and fixing of WHITE SUNMICA BOARDS of various sizes for track insulationplan, station working rule and other diagrams. The board shall be covered with transparentPerspex sheet in aluminium/steel frame, The boards shall be painted in different colourcombination as per directions of Engineer.

ENGINEER

DATALOGGER WORK - EXECUTION

Page 91: Bill of Quantities Pkg-2

39501 EXISTING DATA LOGGER: Supply of new CMU Unit, Installation, rewiring, testing andcommissioning of existing data logger with validation, reprogramming of fault table,software modifications etc. & testing as required by site in charge and commissioning withnetworking. This work may be involved with Shifting of existing data logger with its battery,networking equipments, accessories etc to new location after dismantling from existingplace and transportation to new location.

ENGINEER

39502 This includes either (a) or (b)a Installation, Wiring ,testing and commissioning of Centralized monitoring of Data loggers at

Control Office by linking all Road side dataloggers including conventional and EI Dataloggers complete along with accessories with Contractor's own material. This includesprogramming of data logger for fault diagnostic in suitable structured language inconsultation with Rly.

ENGINEER

b Installation, wiring ,testing and commissioning of Data Logger along with RTU completealong with accessories with Contractor's own material. This includes programming of datalogger for fault diagnostic in suitable structured language in consultation with Rly.

ENGINEER

BLOCK INSTRUMENT WORK-EXECUTION39551 Installation, wiring & testing of block instruments (Single line/Double line) along with bell

unit, filter, polarised relay and other accessories. The work involves supply of wiringmaterial and wiring right from telecom DP to block instrument and Block instrument to relayroom and connection with power supply including fuse wiring. This work may be involvedalong with releasing of complete existing SL/DL block instrument, relay, bell unit, filter,block counter and its accessory and its transportation to new location for further use.

ENGINEER

39552 Installation, wiring & testing of axle counter based block panel for one complete blocksection along with bell unit, filter, relay and other accessories. The work involves supply ofwiring material and wiring right from telecom DP to block Panel and Block Panel to relayroom and connection with power supply including fuse wiring.This work may be involvedalong with releasing of complete existing SL/DL block instrument, relay, bell unit, filter,block counter and its accessory and its transportation to new location for further use.

ENGINEER

INTEGERATED POWER SUPPLY WORK - EXECUTION39601 This includes:

Page 92: Bill of Quantities Pkg-2

a Supply of Flexible Wire Copper multistrand, 25 Sqmm, PVC insulated, insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 0.780 ohms per Km at 20 degreeCentigrade; over all core diameter 10.2 mm±0.25; conductor diameter: 0.40 mm±0.005;Number of conductors:196 and test parameter as per specification no: IRS:S 76/89Amendt-3. For wiring of IPS and Battery in Red and Black Colour - quantity as perrequirement of site and directions by Engineer

RDSO

b Supply of all material, Fabrication and fixing of fuse/termination board made out of 10 mmthick Hylam sheet and fixed with FUSE BLOCKS/ ARA TERMINALS/ HIGH CAPACITYMODULAR POWER TERMINALS, laying and termination of power wires from IPS to thisboard and further extending supply to Relay room and outdoor functions as per instructionof engineer at site.

ENGINEER

c Supply of Flexible Wire Copper multistrand, 16 Sqmm, PVC insulated insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 1.21 ohms per Km at 20 degreeCentigrade; over all core diameter 8.45mm±0.25; conductor diameter: 0.400mm±0.005;Number of conductors:126 and test parameter as per specification no: IRS:S 76/89Amendt-3. For wiring from IPS to fuse/termination board in Red&Black colour for DCsupply, Gray for AC supply and Green for earth wire - in quantity per requirement of siteand direction of Engineer.

RDSO

d Installation, testing and commissioning of Integrated Power Supply (IPS) systems forstations / LC Gate/ IBH or at any other location. Initial charging of lead acid lowmaintenance batteries for IPS, Supply of sulphuric acid to approved specification, distilledwater. Preparation of electrolyte. Charging & discharging of batteries ( 3 cycles). Wiringfrom Auto Change over panel to IPS and from IPS to Fuse/Termination board. Installationtesting and commissioning shall be done by manufacturer as per RDSO guide lines/checklist. All the prescribed protective equipments shall be installed. Connection to Earth shallbe done as per RDSO prescribed standard.

ENGINEER

Page 93: Bill of Quantities Pkg-2

39602 This includea Supply of Flexible Wire Copper multistrand, 25 Sqmm, PVC insulated, insulation thickness

of 1.5 mm±0.15; conductor resistance not exceeding 0.780 ohms per Km at 20 degreeCentigrade; over all core diameter 10.2 mm±0.25; conductor diameter: 0.40 mm±0.005;Number of conductors:196 and test parameter as per specification no: IRS:S 76/89Amendt-3. For wiring of IPS and Battery in Red and Black Colour - quantity as perrequirement of site and directions by Engineer

RDSO

b Supply of all material, Fabrication and fixing of fuse/termination board made out of 10 mmthick Hylam sheet and fixed with FUSE BLOCKS/ ARA TERMINALS/ HIGH CAPACITYMODULAR POWER TERMINALS, laying and termination of power wires from IPS to thisboard and further extending supply to Relay room and outdoor functions as per instructionof engineer at site.

ENGINEER

c Supply of Flexible Wire Copper multistrand, 16 Sqmm, PVC insulated insulation thicknessof 1.5 mm±0.15; conductor resistance not exceeding 1.21 ohms per Km at 20 degreeCentigrade; over all core diameter 8.45mm±0.25; conductor diameter: 0.400mm±0.005;Number of conductors:126 and test parameter as per specification no: IRS:S 76/89Amendt-3. For wiring from IPS to fuse/termination board in Red&Black colour for DCsupply, Gray for AC supply and Green for earth wire - in quantity per requirement anddirection of Engineer

RDSO

d Shifting of existing IPS complete with its associated modules and units and battery bank inthe same building or at remote building. This includes dismantling of complete existing IPSwith its associated modules and units and battery bank, transportation, Reinstallation,Wiring from Auto Change over panel to IPS and from IPS to Fuse/Termination board,wiring of batteries, topping up of battery electrolyte etc, testing and commissioning andearthing connections etc.

ENGINEER

39603 Installation and Commissioning of Single Phase Diesel Generator Set. This includestransportation of DG set from one station/LC to another, repair and maintenance of DG setand supply of adequate quantity of diesel for operation of DG set to enablecontractor/RVNL to test the signaling panel till such time the electric supply is madeavailable.

ENGINEER

CABLE TRENCHING LAYING AND PROTECTION WORK - EXECUTION

Page 94: Bill of Quantities Pkg-2

39651 This includes:a Excavation of trenches at the depth of 1.0 Mtr. deep and 300 mm wide at the bottom of the

trench including clearing of roots, bushes, or other obstruction etc. for all types of soilsincluding Murrum, soft rock, hard soil mixed with boulders etc. as per cable route plan.

Engineer

b Supply of Cable route marker FRP make as per drg no. RVNL/BPL/S&T/SK/FIELD/01 andfixing along the actual cable route after cable laying at regular intervals (not more than 200mtrs on straight route) and at diversions and at other places as decided by site engineer.Minimum of 10 markers to be provided per KM.

Engineer

c Complete back filling the trench after laying required quantity of cable,protectionpipes/bricks, route marker etc and ramming and consolidation of soil as well as disposal ofextra soil as per Drg No. RVNL/BPL/S&T/SK/FIELD/02

Engineer

39652 Excavation of cable trench of 1 m. depth & 300 mm. wide across the track crossing, roadcrossing, level crossing, platform & refilling after laying DWC pipe with collars as per cableroute chart & technical specification as per Drg.

Engineer

39653 Providing chase in hard rock deep enough to fix GI pipe for laying of S&T cable andminimum 100 mm concreting over GI pipe after providing suitable U clamp to GI pipe.Chase to be provided where optimum depth(minimum 0.6 mtrs) is not possible and whichis verified and agreed by engineer in charge of the work or his representative NOTE:Where digging of depth as specified is not possible, the depth can be reduced with theapproval of the engineer in charge and the payment shall be made proportionately

Engineer

Page 95: Bill of Quantities Pkg-2

39654 Perforation ( 24 to 36 perforation in a pipe) and Fixing of GI pipes for entry of cable ongirder bridges, RCC bridges, drains, culverts, rocky places tunnels/deep cutting or atplaces as advised by the engineer in charge of the work & concreting the ends with brickchanneling at both ends as per drg. The pipes are to be fixed on the bridges by suitablebridge fixtures or MS clamps or brick support at an interval of 3.0 mts (max) or as perapproved drawing and directives of Railway Engineers. On masonry bridges or in rockyplace if required the entire length of the pipe by cement, sand and 15-25 mm chips. All thefixing materials nut & bolts, clamps, materials for construction of pillars. MS channel etc.will be supplied by the contractor.

Engineer

39655 Fixing/Laying of RCC pipe(at TSS/SP/SSP), DWC pipes with collars for laying of cables inopen trench or underneath the track, road, platform etc. as directed by Engineer and drg.Issued.

Engineer

39656 Laying of various sizes and types of cables in trenches: Laying of signaling / power /telecom / quad/OFC cable of various sizes in the excavated trench and through laid pipes.This includes loading/unloading & transportation of cables to site. Whenever severalcables are to be laid separation of cables should be as advised by site engineer. Thisincludes unwinding of cable drum using proper jigs without causing damage to cable.

Engineer

39657 Placing of half round ( Split DWC ) pipe over the laid cable in open trenches in yardsbetween Home signal to Home signal and tieing pipe with cable with loose armouring asper Drg.

Engineer

39658 Supply of 20 pair CT Box and fixing on Hylam board on wall and termination of quad/telecom cable at station/ SP/ SSP/ TSS/ LC gate/ Relay room/ office/ residences as perrequirement and details given by engineer at site. The CT box after termination shall besealed by pouring paraffin wax.

Engineer

39659 Testing of point to point insulation / continuity test for all laid out cables, Measuring TrackCircuit Parameters, Measuring Point machine voltage and current parameters, IPSparameters, Axle counter parameters, Measuring Signal parameters for LED lamps as perRDSO check list and preparing the records in a bound register in approved format.

Engineer

COLOUR LIGHT SIGNAL WORK - EXECUTION39751 This includes

Page 96: Bill of Quantities Pkg-2

a Excavation of pit, fixing of foundation scaffolding, casting & plastering of concretefoundation, removal of scaffolding, water curing and earth filling for Colour Light MainSignal and Casting of cement concrete foundation for signal ladder as per drg. Thisincludes : Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.

Engineer

b Erection of Multi aspect colour light signals. This includes : Erection of surface base, signalpost, signal unit, junction type route indicator, and shunt signal on OFF set bracket, callingon signal, ladder with guard & platform, fixing of P/C/G marker, supply & fixing of Heatenammelled signal number plate & blanking-off signals as per the requirement. Making ofholes in CLS post, supply of other minor material like clamps, nuts & bolts, wiring materialetc. Fixing of signal lamps/LED's with accessories on 2/3/4 aspect signal unit, shunt, route,calling on unit as per the requirement. Termination of the tail cable in the signal units,wiring of signal and testing, focusing of signal etc.

Engineer

39752 This includes:a Excavation of pit, fixing of foundation scaffolding, casting & plastering of concrete

foundation, removal of scaffolding, water curing and earth filling for Independent ShuntSignal as per drg. This includes : Supply of cement, sand, stone chip & mixing in the ratio1:3:6.

Engineer

b Erection & wiring of shunt signal. This includes : Erection of surface base, shunt signalpost, shunt signal unit. Supply & fixing of Heat enammelled signal number plate, Fixing oflenses, signal/LED lamp, supply and fixing of antitheft protection etc., where ever required.Termination of the tail cable, supply of wire & wiring of signal unit. Focusing and testing ofshunt signal.

Engineer

DC TRACK CIRCUIT WORK - EXECUTION39801 This includes:a Supply of Power Wire PVC Insulated Single Core multistrand unsheathed with plain

annealed copper conductor as per IRS:S-76/89 Amndt - 3, copper cable of 6 Sq. mm - forwiring in track circuit battery location box in Red & Black colour - in quanitity as perrequirement at site and direction of engineer.

RDSO

Page 97: Bill of Quantities Pkg-2

b Supply of Power Wire PVC Insulated Single Core multistrand unsheathed with plainannealed copper conductor as per IRS:S-76/89 Amndt - 3, cable of 3 x 0.7 sq.mm. inRed& Black colour for wiring of Track charger, choke, resistance in location box - inquanitity as per requirement at site and direction of engineer.

RDSO

c Supply of Cable indoor copper conductor plain annealed high conductivity 650V gradePVC insulated unarmoured IRS-S-76/89 Amndt - 3. - 16 x 0.2 sq.mm in approved colours. -in quanitity as per requirement at site and direction of engineer.

RDSO

d Supply of frame for fixing of relays - as per requirement Engineere Complete work of fixing of hylam sheet supplied with location box, fixing of track circuit

equipment like battery chargers, track feed resistance, choke, relays, fuses, terminals,batteries etc. as per approved wiring diagram in location box/Gumties. Wiring of theseequipments of track circuits with the above supplied wire, wiring of charged batteries etc.,energisation, testing, adjustment of resistance and commissioning of track circuit as perDrg No. RVNL/BPL/S&T/FIELD/05

Engineer

39802 This includes:a Supply of Channel bond pin (single groove,tinned or zinc coated 7mm dia), GI Bond wire

soft(7 strand steel wire 8 SWG), PVC Jacketed wire rope(galvanized wire rope 6mm dia(6x19 standard wire with steel core sheathed with PVC 2 mm wall thickness, overallthickness 10 mm)

Engineer

b Supply of Fibre glass track lead Junction boxes for termination of signaling cable as perdrg. - as per requirement

RITES

c Supply of Nylon Insulation rail joint complete for 52/60 Kg. as per RDSO Drg. & as perspecn.No.IRS-S-40/84 comprising of :2 Nos.-Channel side plate LH, 2 Nos.-Channel sideplate RH, 1 No. End post, 4 Nos. insulating plate, 8 Nos. bushes.

RDSO

d Initial Charging of 3 nos. of batteries of 80AH capacity supplied along with supply schedulefor track circuits.

Engineer

Page 98: Bill of Quantities Pkg-2

e Installation, wiring, testing & commissioning of DC track circuits on track as per instructionof Site Engineer. installation of charged batteries, Drilling of 9/32" holes on rail, Providing,bonding & jumper connection as per track bonding plan. Fixing of track lead junction boxes& track lead connections. Supply of Erico type cable fastener and fixing by glue onConcrete sleppers. Machining of fish plate. Fixing of insulation joint. Energizing the trackcircuit and testing with 0.5 ohms train shunt resistance.This include all preparatory work ofGlued joint bypass bonding, temporaray negetive bonding during NI and other physicaladjustments before commissioning to enable existing Track circuit to continue and postcommissioning bonding across old glued joint.

Engineer

POINT MACHINE WORK - EXECUTION39811 Installation, wiring, testing and commissioning of point machine as per drawing.This

includes fixing of point machines on MS plate fixed on sleepers complete with fixing of antitheft covers, junction boxes, ground connection, trap indicators, crank handle ward etc.where ever required. Supply and fixing of as required insulation for gauge tie plate andcrossing plate, switch extension pieces (D brackets) and leading & following stretcher bars.Supply and fixing of GI bend pipes with welded frame for cable entry to machine.Termination of cable, supply of 3x0.7 wire and wiring of machine as per wiring diagram,adjustment & testing with crank handle operation. This will also includes necessaryadjustment and smithy work, drilling of holes to tongue rails, supply of flat, angle, bolts,nuts, pins as required.Removal & refixing of fittings if required, Testing the point machinesfrom point of operation including testing with 5 mm test piece.

Engineer

39812 Complete work of excavation & Pulling out the old cable from existing point machines,supply and fixing of GI bend pipes with welded frame for cable entry to machine, provisionof fabricated terminal boards for extra cables, insertion of old & additional new cablethrough GI bend pipe, termination of cable, supply of 3x0.7 wire and wiring of machine asper wiring diagram, adjustment & testing with crank handle operation, replacement ofcrank handle wards, testing the point machines from point of operation including testingwith 5 mm test piece.

Engineer

Page 99: Bill of Quantities Pkg-2

39813 Supply,installation and wiring of Ground Frame, Electric point and lock detector, facingpoint lock for a cross over siding point as per arrangement in SIP including supply ofmaterials like GF, EPD, FPL, E-type lock, Split stretcher bar,rodding run, all types ofcranks, compensator, Rod joint with Nylon insulator, Solid joints etc as per RDSO drawing,Supply of nuts, bolts etc. Casting of foundations with cement, sand,and ballast. Erection,of GF, rodding run, crank and compensator, cutting of notches etc. Complete testing andinterlocking with Panel.

RITES FOR SUPPLYITEMS

LOCATION BOX WORK - EXECUTION39821 This include:a Excavation of pit, casting of concrete foundations for SINGLE location box as per Drg no.

RVNL/S&T/SK/FIELD/03. This includes:(a)Supply of cement, sand, stone chip & mixing inthe ratio 1:3:6. (b)Supply of 4 Nos. foundation bolts as per Drg.No.SA-112A with Nuts &bolts. (c) Masonry work with brick platform shall be done where specifically asked for.

Engineer

b Erection of Single location box on foundation with bolts and washer including fixing of `E’type lock, Supply and fixing of Universal lock on both side.

Engineer

c Fixing of hylum sheet, fixing of terminals, fuse blocks, ND Fuses etc., termination of cableswith no. embossed ferrules, bunching of cables with PVC tape, supply of ferrules, tape,including supply & fixing of PVC coated string rods at the back side for the cable supportwith contractor's own material, Supply and fixing of 2 pin lamp holder with switch.Preparing Hylam shelf as per requirement for placing equipment and batteries, Supply offrame for relay fixing, fixing of relay bases & relay etc. as per approved location boxdiagrams.

Engineer

d Supply of 3x0.7 and 16/0.2 wiring material and wiring of terminals, fuse blocks, N.D. fuses,relays, lamp & switch etc and complete wiring , testing and commissioning of location boxequipments.

RDSO

39822 This include:

Page 100: Bill of Quantities Pkg-2

a Excavation of pit, casting of concrete foundations for HALF location box as per Drg no.RVNL/S&T/SK/FIELD/03. This includes:(a)Supply of cement, sand, stone chip & mixing inthe ratio 1:3:6. (b)Supply of 4 Nos. foundation bolts as per Drg.No.SA-112A with Nuts &bolts. (c) Masonry work with brick platform shall be done where specifically asked for.

Engineer

b Erection of HALF location box on foundation with bolts and washer including fixing of `E’type lock, Supply and fixing of Universal lock on both side.

Engineer

c Fixing of hylum sheet, fixing of terminals, fuse blocks, ND Fuses etc., termination of cableswith no. embossed ferrules, bunching of cables with PVC tape, supply of ferrules, tape,including supply & fixing of PVC coated string rods at the back side for the cable supportwith contractor's own material, Supply and fixing of 2 pin lamp holder with switch.Preparing Hylam shelf as per requirement for placing equipment and batteries, Supply offrame for relay fixing, fixing of relay bases & relay etc. as per approved location boxdiagrams.

Engineer

d Supply of 3x0.7 and 16/0.2 wiring material and wiring of terminals, fuse blocks, N.D. fuses,relays, lamp & switch etc and complete wiring , testing and commissioning of location boxequipments.

RDSO

39823 WORKING IN EXISTING LOCATIONS: Excavation of cable pit without damaging existingworking cables, laying & insertion of new extra cables. Provision of additional terminals,fuse blocks, etc. on the Hylam board in the location. Drilling of holes in Hylam sheet forcables, retermination of existing cable on one side of terminal to keep present systemworking. Provision of additional Hylam board / shelf / adjustment / shifting of existinglocated equipments such as charger, relays, resistance etc. & rewiring the same.Meggering of cables, dressing of cables etc. Numbering & writing description of newcircuit. Closing of excavated cable trench/Pit & plastering of foundation etc. underinstruction from site Engineer.

Engineer

LEVEL CROSSING GATE WORK - EXECUTION39851 Design fabrication & supply of Supply of Gate indication panel made of 16 SWG powder

coated MS sheet of size 39cm x24 cmx10cm approx. consisting of different colour LEDswith holders to work on 24 V DC/60 V DC supply.( Diagram to furnished by Engineer)

Engineer

Page 101: Bill of Quantities Pkg-2

39852 Installation, wiring, testing and commissioning of Electrical/Mechanical Lifting Barrier,complete with casting of cement concrete foundation as per manufacturer's drawing forpedestal and boom rest, post, wire run, operating winch/Panel, Rodding, cabling, powersupply connection, wiring in loc. box or in rack etc. Wiring of Hooter, Flasher and roadsignals. Supply, provision, fixing and wiring of Electric key transmitter and establishment ofinterlocking as per approved diagram.

Engineer

39853 Shifting of existing power operated lifting barrier: Dismantling of one side lifting barrier andreerrecting the same at new location, insertion of new/additional/existing cables into liftingbarrier, termination & wiring of the cables, adjustment of the circuit controllers. Excavationof pit and casting of foundation for the pedestal / rest post and plastering the same.Installation of pedestal & rest post & boom. Shifting & adjustment of equipments to becarried out as per instructions of site in charge.This include termination ofexisting/additional/new cable in the relay room/loc box of the gate lodge for the gate panelto be carried out as per given circuit.

Engineer

MISCELLANEOUS WORK - EXECUTION39901 This includesa Supply of MAINTENANCE FREE EARTHING AND BONDING SYSTEM (Two Earth Pit) as

per RDSO specification no: RDSO/SPN/197/2008 consisting of (a) Earth electrodes madeof high tensile low carbon steel circular rods, molecular bonded with copper on outersurface as per RDSO spn - 2 no. (b) RDSO approved Earth Enhancing compound (c)(MEEB) Main equipotential earth busbar of Copper of 300x25x6 mm(Min) and (SEEB) Subequipotential earth busbar of copper 150x25x6 mm(Min) (d) Multistrand single core PVCinsulated copper cable as per IS:694 -(i) of size 10 sqmm to connect individual equipmentto SEEB using copper lugs with stainless steel nuts and bolts,(ii)of size 16 sqmm toconnect SEEB to MEEB using copper lugs with stainless steel nut and bolts (iii) of size16sqmm to connect Surge protection devices(SPD) to MEEB using copper lugs withstainless steel nut and bolts (iv) of size 35 sqmm(duplicated) to connect MEEB to mainearth electrode (e) Copper tape of size 25x2mm to connect the two earth pits, (f) Earthpitsx 150 mm to terminate on earth electrode.

RDSO

Page 102: Bill of Quantities Pkg-2

b Construction of earthpit and making of earth as per RDSO specificationno.RDSO/SPN/197/2008 and drawing no: SDO/RDSO/E&B/001, Equipotential Earth busbar and its connection to equipments and surge protection devices in the equipment roomas RDSO Drg. no. SDO/RDSO/E&B/002. Provision of Exothermic weld connections,fixtures for mounting the Copper tape in the relay room, weld materials, tools & fixtures forthe weld shall be arranged by the contractor.

Engineer

39902 Shifting of existing protection,diagnostic equipments like ELD, Fire alarm system, Fireextinguisher and other indoor equipmentsetc. complete with its associated units byreleasing from existing location with its associated units, transportation, reinstallation,wiring, testing and commissioning at new location.

Engineer

39921 This includesa Supply of Block Section Limit Board (BSLB)/ Shunting Limit Board(SLB) - rectangular

board of size 600mm x 1000 mm, height from the rail level to the underside of the boardcontaining the cross 2 meter. The post shall be painted black and white alternatively by300mm vide strips. The board shall be painted by yellow reflecting paint with black crosslines. This will be as per annexure 6 para 12.134 sheet 4 of signal engineering manual.

Engineer

b Installation of various boards like BSLB/GWB/STOP boards as per standard practice atsite. The necessary material like cement, concrete and sand etc for the installation ofthese boards shall be supplied by contractor. The cement, concrete and sand for theseboards shall be in proportion of 1:2:4 of size 30x30x30 cms and finished with cementplaster 1:2 above ground level. This shall be got done under supervision of site engineer.

Engineer

Page 103: Bill of Quantities Pkg-2

39922 Supply of earth electrodes assembly to RVNL drg. The length of Earth Electrode shall be2950 mm. Installation of Earth electrode & connecting to location box, signal unit, blockinstruments, lever frames, power equipments, cables, telecom equipments etc. through GIwire 8 SWG suitably connected on MS flats size 40 x 5 mm with complete contractor'smaterial (excluding earth electrode) as per drg. issued by Railway. This includes digging ofpit in earth 3 M deep, casting of cement concrete enclosure. Soil treatment as perstandard practice involving supply & pouring of salt & charcoal, connecting the equipmentthrough earth lead wire & soldering and supply of cement. wiring material & solderingmaterial.

RITES FOR SUPPLYITEMS

39923 Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200SWG of size 1200 x 1500 mm on signals as per extant practice & connection to earth andas per instruction of Rly engineer at site.

Engineer

39924 Provision of temporary Goomtis for NI working, made up of water proof tent with provisionof one table, one chair, and two incandescent lamps (Electrical connection for lamps to bearranged seperately) and establishing communication on magneto phone and spareconductors. Provision of Public Address system complete with Microphones, speaker etcin the cabin/station/yard during Non Interlock working on hire basis.

Engineer

PAINTING WORK - EXECUTION39951 This includea Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after

scrapping and cleaning of the surface wherever necessary with contractor own supply ofprimer and paints over all INDOOR & OUTDOOR GEARS of Station like EI, Relays, Relayrack, CT rack etc.in Relay room & SM room, lifting barrier, axle counter, ground frame,point machine, location boxes, signal post, unit, track circuits etc.

Engineer

b Lettering / Numbering Termination particulars, equipment names etc. legibly and neatlyinside and outside surfaces with contractor own supply of paints over all INDOOR &OUTDOOR GEARS like EI, Relays, Relay rack, CT rack etc.in Relay room & SM room.The work shall be done as per extant practice & the instructions of Rly engineer at site.(Paints to be used shall conform to relevant IS spec.)

Engineer

39952 This include

Page 104: Bill of Quantities Pkg-2

a Painting two coats of synthetic enamel paint over one coat of Red Oxide primer afterscrapping and cleaning of the surface wherever necessary with contractor own supply ofprimer and paints over all INDOOR & OUTDOOR GEARS of IBH/Midsection InterlockedLC gate/ Auto Huts like EI, Relays, Relay rack, CT rack, Lifting barrier, ground frame,location boxes, signal, track circuits etc.

Engineer

b Lettering / Numbering Termination particulars, equipment names etc. legibly and neatlyinside and outside surfaces with contractor own supply of paints over all INDOOR &OUTDOOR GEARS of IBH/Midsection Interlocked LC gate/ Auto Huts like EI, Relays,Relay rack, CT rack, Lifting barrier, ground frame, location boxes, signal, track circuitsetc.The work shall be done as per extant practice & the instructions of Rly engineer at site.(Paints to be used shall conform to relevant IS spec.)

Engineer

RELEASING & TRANSPORTATION WORK - EXECUTION39961 This include:a Dismantling and Release of complete INDOOR equipment from stations/IBH/LCgates and

transportation of released material after commissioning from the station/IBH/LC to theS&T store depot or to other site for reusing with contractors own transport as per directionof site Engineer. Most of the indoor released material like - Relays, relay racks, Baseplates, CT rack, Terminals, IPS, Tagblock, Datalogger, ELD, Block Instruments, Filter unit,Key lock box with relays etc are proposed to be reuse at the same station or at otherstations, thus releasing to be done carefully with out damaging the equipments. Thequantity of released material shall be jointly recorded by the contractor andEngineer's/railway representative before releasing from site.

Engineer

b Dismantling and Release of complete OUTDOOR equipment from stations/IBH/LCgatesand transportation of released material after commissioning from the station/IBH/LC to theS&T store depot or to other site for reusing with contractors own transport as per directionof site Engineer.Most of the released material like - Signal, Point machine with groundconnection, Track relays, and track equipments, axle counter, EC socket and post, gatetelephone etc are proposed to be reused at the same station or at other stations, thusreleasing to be done carefully with out damaging the equipments. The quantity of releasedmaterial shall be jointly recorded by the contractor and Engineer's/railway representativebefore realesing from site.

Engineer

Page 105: Bill of Quantities Pkg-2

39962 Shifting/ lifting of existing location boxes/ signals/Track lead boxes, junction boxes etcalong with foundation to adjacent place to facilitate earth work/ clearing infringement etc atstations including IBH, LC gates etc.

Engineer

39963 Loading, unloading and transportation of additional/balance Signal and telecom materialsafter completion of work or during execution of work, to and from Railway/RVNL otherstores depot to and from the site of work. Note: This does not include transporatation ofmaterial from nominated depo to site and back or from site to site, which is to be done bycontractor free of cost.

Engineer

Page 106: Bill of Quantities Pkg-2

ANNEXURE

S.No. DESCRIPTION MAKE SIZE QTY1 Non-insulated flat plier. ( Taparia /Jhalani ) 200 mm. 12 Insulated flat plier. 125 mm. 13 Insulated side cutting plier. -do- 6 inch. 64 Combination plier. 200 mm 25 Insulated striping plier. 150 mm 36 Insulated nuse plier. 150 mm 37 Monkey plier. 10 inch. 18 Screw Driver ( Insulated ). -do- 150 x 3 mm 19 Screw Driverd ( Insulated ). -do- 150 x 4 mm 1

10 Screw Driver ( Insulated ). -do- 150 x 5 mm. 111 Screw Driver ( Insulated ). -do- 150 x 6 mm 112 Screw Driver ( Insulated ). -do- 150 x 8 mm 113 Screw Driver (Insulated ). -do- 250 x 8 mm 114 Screw Driver ( Insulated ). -do- 250 x 10 mm 115 Flat coarse file with handle. 150 mm 116 Round fine file with handle. 150 mm 117 Hammer with handle. 500 Cms. 118 Brass Brush. 219 Spanner double ended. ( Taparia Jhalani ) 6 x 7 mm 220 Spanner double ended. -do- 8 x 9 mm 221 Spanner double ended. -do- 10 x 11 mm 222 Spanner double ended. -do- 12 x 13 mm 223 Spanner double ended. -do- 14 x 15 mm 224 Spanner double ended. -do- 16 x 17 mm 225 Spanner double ended. -do- 18 x 19 mm 226 Spanner double ended. -do- 20 x 22 mm 227 Spanner double ended. -do- 21 x 23 mm 228 Spanner double ended. -do- 24 x 26 mm 229 Spanner double ended. -do- 25 x 28 mm 230 Spanner double ended. -do- 27 x 32 mm 231 Spanner double ended. -do- 30 x 32 mm 232 Hack saw frame. 6 inch. 233 Hack saw frame. 12 inch. 234 Hack saw blade. ( Miranda Make ) 12 x 1/2 inch. 635 Hack saw blade. 6 x 1/4 inch. 636 Steel measuring tape. ( Frumen Make ) 3 Mt. 237 Adjustable screw wrench. -do- 6 inch. 238 Adjustable screw wrench. -do- 12 inch. 239 Adjustable screw wrench. -do- 15 inch 240 Bench vice, size. 241 Level bottle. 242 Soldering Iron 230V, 100W. ( Keertone Make ) 143 Soldering Iron 230V, 65 W. -do- 444 Soldering Iron 230V, 25W. 245 Box spanner. 5m. 246 Box spanner. 6mm 247 Box spanner. 7mm 248 Box spanner. 8 mm 249 Box spanner. 9 mm 250 Box spanner. 10 mm 251 Box spanner for OBA Terminals 4

LIST OF ITEMS REQUIRED IN TOOL KIT

Page 107: Bill of Quantities Pkg-2

with plastic handle52 Tap set. 3 mm 153 Tap set. 4 mm 154 Handle for tap. 155 Multimeter 3 and half digit 456 Megger 500 V. DC 257 Tool box of GI sheet 185 1

WC with Navtal Lock. 158 Crimping Tool . 159 Digital Tong meter. 2

Note If any make as mentioned above is not available in the market then the

Fluke 76 or latestMOTWANE MAKE

3D make (CAT No. 3D-3) OR EQUIVALENTMECHO MAKE 2727 OR EQUIVALENT

Page 108: Bill of Quantities Pkg-2

SR.NO DESCRIPTION SIZE UNIT QTY1 Relay rack with all fixtures and spacers. Nos. 1

2 IDF piller with fixtures. Nos. 13 Top frame angle for 2 relay rack. 65x65x1105mm Nos 14 Bottom frame angle for 2 relay rack. 65x65x1105mm Nos 15 IDF Bottom angle for 4 pillers. 65x65x1105mm Nos. 26 IDF Top angle for 4 pillers. 65x65x1105mm Nos 27 Vertical support angle RH Nos 18 Vertical support angle LH Nos 19 Triangle Base assembly with 'J' Bolts, nuts,

flat and spring washers.Nos 2

10 Insulaters with fixing studs, spring and flat wahsers (one stud each for one insulater).Stud size-

12x25mm & 12x20mm. Nos 8

11 Cable suopport assembly i.e. 'L' Bracket with 4 Nos. of bolts with nut, spring and plain washers for each 'L' Bracket.

8 x 25 mm, 6x50 mm.Nos 4

12 16-way fuse holders (1.6 A/0.6A) mounting stripes with studs, spring and plain washers.

Nos 3

13 8-way fuse holders (6A) mounting stripes with stud, spring and plain washers. Nos 1

14 Bracket for mounting 16-way/8-way fuse stripes with nuts, bolts and washers, i.e. (top brackets) All angles & stripes shall be 6mm and 5mm thick respectively.

Sets. 2

15 Bracket for mounting 16-way fuse stripes (i.e. bottom bracket).

Sets. 2

16 Cable supporting stripes 5x20x210mm Nos 1017 Cable supporting stripes 5x20x150mm Nos 418 String rod with PVC insulation (sleeve)

fixing bracket and stud with spring and plain wshers.

Nos 10

19 11-way Bus bar with 16 sq.mm. Lugs with PVC covers & fixing arangement (Bracket for fixing Bus bar cover) nut & bolts.

Nos 2

20 Square bar for fixing 8 Nos. of mini group base plate.

Nos 16

21 PVC sleeve (Tube) for insulting wire run support on IDF pillars and at other places.

16mmMtrs. 15

Angle of various sizes for frame wall support and cable run support (interspacing between racks) (All angles of 6 mm thick).

a) Angle 65x65x2000mm Nos. 1b) Angle 40x40x2000mm Nos. 1c) Angle 40x40x1325mm Nos. 1

ANNEXURE

LIST OF SCAFFOLDING MATERIALS REQUIRED FOR 1 RELAY RACK OF SIEMENS TYPE

22

Page 109: Bill of Quantities Pkg-2

d) Angle 40x40x1000mm Nos. 2e) Angle 65x65x1000mm Nos. 1Angle pieces for fixing wall support angles with 'J' bolts, Nuts, springs and plain washers having 13mm holes and 8mm holes.a) Angle piece with 23mm holes at both 65 mm side

65x65x65 Nos. 1

b) Angle piece with one hole 13mm and other 9mm on 40mm side.

40x40x35 Nos. 2

24 Cable support 'U' bracket 540x100 mm Nos. 325 C' Bracket for cable run support (5mm

thick) 20mm width MS flat to be used.200x200mm Nos. 6

26 C' Bracket for cable run support 5mm thick MS flat to be used.

200 x 150 mm x 20mm width.

Nos. 6

27 Signal resistance mounting assembly complete with fixtures and fasteners.

Sets. 1

Guide rails with fixtures and fasteners for :

a) Point groujp (RRI) Nos. 1b) Point chain group Nos. 1c) Route group Nos. 1d) Main signal group Nos. 1e) Shunt signal group Nos. 1

29 MS Flat strip for mountiong AG timers Sets. 130 Resistance and condenser mounting

assembly Qty. and size as per circuit requirements.

Lot 1

Anodized nuts and bolts with plain and spring washers.a) 'J' Bolts for fixing square bars. Nos. 10b) Studs for fixing relay base plate. 4x20mm Nos. 100c) Bolts with nuts. 6x20mm Nos. 15d) Bolts with nuts. 6x25mm Nos. 100e) Bolts with nuts. 6x40mm Nos. 10f) Bolts with nuts. 6x50mm Nos. 10g) Bolts with nuts. 6x75mm Nos. 5h) Bolts with nuts. 8x25mm Nos. 5I) Bolts with nuts. 12x25mm Nos. 5

32 Rack joining pieces. Nos. 1Ladder for cable run support and power wiring with ladder joining pieces and bolts with nuts and washers.a) 400x1500mm. 40x40x6mm Nos. 1b) 200x1500mm. 25x25x5mm Nos. 2c) 150x1500mm. 25x25x3mm Nos. 2

34 Blue colour PVC sleeve. 2.5mm Mtrs. 2035 Relay rack designation board, L shape

complete with fixing clamps.Nos. 2

NoteNoteNote

28

31

33

M.S. angle and straps should be of MALHOTRA or TISCO OR Above list is indicative, and suitable for Siemens type relays based installations, any other material fy

23

Page 110: Bill of Quantities Pkg-2

Sr. No.

Description of signaling Gears

Equivalent Function. IINPUT

Equivalent Function. Output

EQUIVALENT FUNCTION

APPROX NO OF GEARS IN 3 LINE STN IN SINGLE LINE

FUNCTION VALUE

APPROX NO OF GEARS IN FOUR LINE STN IN DOUBLE LINE

FUNCTION VALUE

APPROX NO OF GEARS IN FIVE LINE STATION IN DOUBLE LINE

FUNCTION VALUE

APPROX NO OF GEARS IN FIVE LINE STN IN THIRD LINE SECTION

FUNCTION VALUE

1 Signal Two aspect 2 1 3 6 18 5 15 7 21 8 242 Signal Three aspect 3 2 5 6 30 4 20 8 40 12 603 Signal Four Aspect 4 3 7 0 0 2 14 1 7 4 284 Junction route indicator -

One way1 1 2 0 0 4 8 4 8

5 Junction route indicator - Two way

2 2 4 2 8 2 8 1 4 5 20

6 Junction route indicator - Three way

3 3 6 0 0 1 6 1 6

7 Junction route indicator - Four way

4 4 8 0 0 0 2 16

8 Calling on Signal 1 1 2 2 4 2 4 6 12 12 249 Shunt Signal

(Dependent)2 1 2 4 8 4 8 6 12 12 24

10 Shunt Signal (Independent)

2 1 3

11 Track Circuit 1 0 1 25 25 32 32 40 40 55 5512 Cross over Point (Signal

ended/Double ended)2 2 4 5 20 7 28 10 40 14 56

13 L.C.Gate - Traffic 2 2 4 1 4 1 4 1 4 1 414 G.F.Operated Point 2 2 4 1 4 1 4 2 8 2 815 Block Instrument 1 1 2 2 4 2 4 3 6 4 816 Axle Counter (One track

section)1 1 2 2 2 2 3 3 4 4

17 Crank Handle 1 1 2 4 8 7 14 10 20 14 2818 Slot Outgoing 1 1 1 2 2 2 2 2 2 4 419 Slot Incoming 1 1 1 2 2 2 2 2 2 4 4

TYPICAL FUNCTION TABLE OF EI