Top Banner
Bill Hider, N3RR Grounding
24

Bill Hider, N3RR

Jan 15, 2016

Download

Documents

melissa arteaga

Grounding. Bill Hider, N3RR. Grounding = Controlling Lightning!. For Protection!. Personnel Equipment House/Facility. Specifically, Protect What @ N3RR?. Personnel in the shack The Ham Shack/house Electronic equipment in the shack (TX, RX, AMPS, PCs, and the like) - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Bill Hider, N3RR

Bill Hider, N3RR

Grounding

Page 2: Bill Hider, N3RR

Grounding =Controlling Lightning!

Page 3: Bill Hider, N3RR

Personnel

Equipment

House/Facility

For Protection!

Page 4: Bill Hider, N3RR

Personnel in the shack

The Ham Shack/house

Electronic equipment in the shack (TX, RX, AMPS, PCs, and the like)

Electronic and Electrical equipment elsewhere in the house

Specifically, Protect What @ N3RR?

Rotors and their controllers

Antennas

Tower-mounted relay switchers

Tower

Page 5: Bill Hider, N3RR

Specifications/StandardsANSI/TIA/EIA-222-E

Available From: http://global.ihs.com/

Page 6: Bill Hider, N3RR

Technical Information/Documentation

www.polyphaser.comhttp://www.lightningEliminators.com/

Many others. Search for “Lightning”

Page 7: Bill Hider, N3RR

Outdoors:The Ground Grid

Page 8: Bill Hider, N3RR

Controlling Lightning (Tower)

Page 9: Bill Hider, N3RR

Controlling Lightning (Tower & Shack)

Page 10: Bill Hider, N3RR

134 Ft Tower

52 FtTower

Tel&AC

SPG Box

HouseHamShack

=

==

=

=

8 Ft ground Rod w/clamp

Elevated guy anchor

1.5 Inch copper strap

# 4 wire

TELCO and AC power entry

= Common Tie-pointKEY

125 feet

125 feet

125

feet

8 Ft ground Rod w/Cadweld=

Not to Scale

Page 11: Bill Hider, N3RR

N3RR – Grounding @ TowerLightning protectors:http://www.polyphaser.com/

Reference site:www.erols.com/n3rr

Steel Hoffman Boxeshttp://www.hoffmanonline.com/:Andrew Ground Kits

http://www.andrew.com:

PolyPhaser Lightning Protectors:

Page 12: Bill Hider, N3RR

N3RR – Grounding @ TowerTower leg w/ground wires shown

Page 13: Bill Hider, N3RR

N3RR – Grounding @ Tower

Not shown (on the tower):MOVs at each Ring Rotor – from each control wire to groundMOVs at the 80 Meter antenna relay box– from each control wire to ground

Andrew Ground Kit from each coax to ground as close to each antenna as possible

Page 14: Bill Hider, N3RR

Guy anchor ground wires

N3RR – Grounding @ Guy Anchors

Page 15: Bill Hider, N3RR

N3RR – Grounding – SPG @ House

Page 16: Bill Hider, N3RR

134 Ft Tower

52 FtTower

Tel&AC

SPG Box

HouseHamShack

=

==

=

=

8 Ft ground Rod w/clamp

Elevated guy anchor

1.5 Inch copper strap

# 4 wire

TELCO and AC power entry

= Common Tie-pointKEY

125 feet

125 feet

125

feet

8 Ft ground Rod w/Cadweld=

Not to Scale

Review

Page 17: Bill Hider, N3RR

N3RR – Grounding – SPG @ HouseOther Connections

Beverage coax entry & left side copper ground strap: Copper strap grounding to 8

ft copper ground rod:

Page 18: Bill Hider, N3RR

N3RR – Grounding – SPG @ HouseOther Connections

Other end of copper ground strap (after 3 ground rods):

Page 19: Bill Hider, N3RR

Indoors:The SPG Grid

Page 20: Bill Hider, N3RR

House

SPG Box

(External)

TELCO& Electric

Ham Shack

SPG Wall PanelAll equipment grounds “home-run” to this SPG panel.All coax passes through this panel with “double-barrel” feed-through connectors.

Page 21: Bill Hider, N3RR

N3RR – Grounding –InsideElectrical box to ground strap connection:

Page 22: Bill Hider, N3RR

N3RR – Grounding –Inside

SPG panel inside:

Page 23: Bill Hider, N3RR

N3RR – Grounding – Results

Since November 1994, one IC-781, IC-4KL, 5 Ring Rotors,One Hy-Gain rotor, 4 Packet Cluster Radios, 2 PCs,

with all antennas hooked up.

Only one failure due to elecrical shock: I left the ground wire off of a Ring Rotor controller durning a period of 1 week for maintenanceand a nearby lightning strike burned out an internal Zener diode.

NO OTHER FAILURES IN OVER 10 Years CONTINUOUSLY CONNECTED!

Page 24: Bill Hider, N3RR

N3RR – Grounding – THE END!