Benchmark Demonstration: Comparison of WRc-based CCTV Inspections v. Electro Scanning Topsham, England 8 November 2012 Presented in Cooperation with South West Water Pell Frischmann, and Electro Scan Inc. 1 Topsham
42

Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

May 02, 2018

Download

Documents

phungliem
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Benchmark Demonstration: Comparison of WRc-based CCTV Inspections v. Electro Scanning Topsham, England 8 November 2012

Presented in Cooperation with South West Water Pell Frischmann, and Electro Scan Inc. 1

Topsham

Page 2: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

A Special Thanks to Pell Frischmann Consulting Engineers for hosting Electro Scan’s Inaugural Demonstration in the UK, Thursday 8 November in Topsham (near Exeter). 2

Selected Attendees

Page 3: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Topsham Demonstration 8 Nov 2012

3

Page 4: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Topsham Demonstration 8 Nov 2012

4

Page 5: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Challenge Use Electro Scan ,in accordance with ASTM F2550-06, to assess a UK sewer pipe that had been previously televised, in accordance with WRc UK CCTV standards, that found no evidence of infiltration or leaks.

5 http://www.astm.org/Standards/F2550.htm

Page 6: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Principle of Operation

• Electro-scanning is carried out by pulling the probe through the pipe at a speed of 10 m/minute (30 ft/minute) and measuring the variation of electric current flowing between the probe and the fixed electrode on the surface. When the probe is close to a pipe defect the electric current increases because the defect decreases the electrical resistance of the pipe wall. The probe is designed to measure only that electric current which flows through a circular test band around the pipe wall. The test band is about 30 mm (1 inch) wide and located at the middle of the probe.

• As the probe is pulled through the pipe the electric current flow and the position of the probe in the pipe are recorded and displayed in real time as a “current trace” on a notebook computer (Figure 5). When the middle of the probe is within 20 to 30 mm of a defect in the pipe wall the electric current through the pipe wall increases, attaining a maximum value when the center of the probe is radially aligned with the defect.

ASurface Electrode

VoltageSource

ElectricCurrentMeter

Probe Cable Defect Electrode test bandProbe

LOW resistance paththrough ground

HIGH resistance paththrough pipe wallexcept where there is awater leakage paththrough wall

LOW resistance path through water in pipe Pipe fullof waterat probelocation

6

Page 7: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Run 1 Analysis ANOMALY ANALYSIS

Anomaly Picking Threshold 100.00

Grade Current Levels

Number Length % Length of Pipe Tested

% of Total Anomaly Length

Grade Large >700 1 0.0 0% 1% Medium 700 to

400 6 0.7 3% 72%

Small <400 21 0.3 1% 27% Total 28 1.0 5% 100%

Grade Flow

Levels Number Flow

lt/min Flow lt/sec

>15 1 40.7 0.6783 15 to 5 0 0.0 0.0

<5 27 36.8 0.6133 <1 28 77.5 1.2916

7

Page 8: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Run 2 Analysis

ANOMALY ANALYSIS

Anomaly Picking Threshold 100.00

Grade Current Levels

Number Length % Length of Pipe Tested

% of Total Anomaly Length

Grade Large >700 0 0.0 0% 0% Medium 700 to

400 4 0.2 1% 13%

Small <400 24 1.0 5% 87% Total 28 1.2 6% 100%

Grade Flow

Levels Number Flow

lt/min Flow lt/sec

>15 1 23.0 0.3833 15 to 5 2 12.0 0.2000

<5 25 32.6 0.5433 <1 28 67.6 1.126

8

Page 9: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Topsham Defect Analysis ANOMALY ANALYSIS

Anomaly Picking Threshold 100.00

Grade Current Levels

Number Length % Length of Pipe Tested

% of Total Anomaly Length

Grade Large >700 1 0.0 0% 1% Medium 700 to

400 6 0.7 3% 72%

Small <400 21 0.3 1% 27% Total 28 1.0 5% 100%

ANOMALY ANALYSIS

Anomaly Picking Threshold 100.00

Grade Current Levels

Number Length % Length of Pipe Tested

% of Total Anomaly Length

Grade Large >700 0 0.0 0% 0% Medium 700 to

400 4 0.2 1% 13%

Small <400 24 1.0 5% 87% Total 28 1.2 6% 100%

Grade Flow

Levels Number Flow

lt/min Flow lt/sec

>15 1 40.7 0.6783 15 to 5 0 0.0 0.0

<5 27 36.8 0.6133 <1 28 77.5 1.2916

Grade Flow

Levels Number Flow

lt/min Flow lt/sec

>15 1 23.0 0.3833 15 to 5 2 12.0 0.2000

<5 25 32.6 0.5433 <1 28 67.6 1.126

Notes: • A variance of defect quantification within the expected + or – 20% range is shown as expected. This generally

occurs as a result of changes in the nature of the contact between the pipe wall and ground in the trench. As more water is forced out through a defect, it pushes the earth away from the pipe, slightly reducing the amplitude of electrical leakage.

• Due to the grading of defects occurring at a definite point (ie. 700) some defects may be graded differently as this + or – 20% variance occurs.

Run 1

Run 2

9

Page 10: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity -0.117 0.205 322 554 M

2.79 2.88 90 249 S

3.951 3.951 0 161 S

4.563 4.563 0 116 S

5.072 5.072 0 112 S

5.664 5.664 0 132 S

7.542 7.564 22 581 M

8.221 8.221 0 113 S

8.778 8.778 0 238 S

9.388 9.676 288 695 M

9.93 9.947 17 422 M

10.637 10.689 52 423 M

11.869 11.869 0 191 S

12.398 12.424 26 128 S

12.48 12.649 169 479 M

13.079 13.079 0 132 S

13.676 13.707 31 317 S

14.901 14.901 0 116 S

15.462 15.462 0 117 S

16.68 16.68 0 130 S

16.743 16.76 17 242 S

17.355 17.369 14 138 S

17.981 17.992 11 202 S

18.642 18.667 25 385 S

18.851 18.883 32 168 S

18.901 18.912 11 284 S

19.296 19.32 24 188 S

19.836 19.836 0 200 S

Topsham Defect Analysis Notes: • Defect location appears to

be offset from CCTV measurements by as much as 0.13 m (towards end of pipe) due to differences in zeroing of data cable, and potential slack in CCTV data cable.

• Defects with length reading of ‘0’ are considered radial pipe defects of < 10mm in size.

• Regular interval of defects indicated many leaking joints.

10

Page 11: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Electro Scan

Size Grading of Defect

Number of Defects Identified

Small 24

Medium 4

Large 0

Total 28

Electro Scan and CCTV Comparison

CCTV

Nature of Defect

Number of Defects Identified

Grade

Structural 1 1

Service 3 4

11

Page 12: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Electro Scan and CCTV Comparison

12

Page 13: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

CCTV Screenshot Comparisons

The following analysis shows a screenshot taken at the location of each defect identified with Electro Scan in this trial. Notes: • Visual comparisons will note distances slightly

less than those recorded on Electro Scan report. This is due to the need to stop the camera short of defects in order to get a screenshot of them.

13

Page 14: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Manhole Connection Defect

Notes: Most significant leak in pipe.

CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity -0.117 0.205 322 554 M

No Photo Available on CCTV video. Inspection started at 0.4m

14

Page 15: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 2.79 2.88 90 249 S

15

Page 16: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 3.951 3.951 0 161 S

16

Page 17: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 4.563 4.563 0 116 S

17

Page 18: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 5.072 5.072 0 112 S

18

Page 19: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 5.664 5.664 0 132 S

19

Page 20: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 7.542 7.564 22 581 M

20

Page 21: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 8.221 8.221 0 113 S

21

Page 22: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 8.778 8.778 0 238 S

22

Page 23: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 9.388 9.676 288 695 M

23

Page 24: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 9.93 9.947 17 422 M

24

Page 25: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 10.637 10.689 52 423 M

25

Page 26: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 11.869 11.869 0 191 S

26

Page 27: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Small Longitudinal Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 12.398 12.424 26 128 S

Notes: Evidence of minor cracking @ 5 o‘clock

27

Page 28: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 12.48 12.649 169 479 M

Notes: Evidence of minor cracking @ 5 o‘clock continuing on from joint.

28

Page 29: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 13.079 13.079 0 132 S

29

Page 30: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 13.676 13.707 31 317 S

30

Page 31: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 14.901 14.901 0 116 S

31

Page 32: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 15.462 15.462 0 117 S

32

Page 33: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Small Longitudinal Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 16.68 16.68 0 130 S

Notes: Evidence of minor cracking @ 9 o‘clock.

33

Page 34: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 16.743 16.76 17 242 S

34

Page 35: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 17.355 17.369 14 138 S

35

Page 36: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 17.981 17.992 11 202 S

36

Page 37: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 18.642 18.667 25 385 S

37

Page 38: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Small Longitudinal Defect CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 18.851 18.883 32 168 S

18.901 18.912 11 284 S

Notes: Evidence of minor cracking @ 9 o‘clock.

38

Page 39: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

CCTV Call Out: None

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 19.296 19.32 24 188 S

Defect Identified: Small Longitudinal Defect

Notes: Evidence of minor cracking @ 9 o‘clock.

39

Page 40: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

Defect Identified: Joint Defect CCTV Call Out: OJM – Open Joint Medium

Defect Start (m)

Defect End (m)

Defect Length (mm)

Defect Max

Current Defect

Severity 19.836 19.836 0 200 S

40

Page 41: Benchmark Demonstration: Comparison of WRc-based … · Benchmark Demonstration: Comparison of WRc-based . ... in accordance with WRc UK CCTV standards, ... 15.462 . 0 . 117 . S .

CCTV, alone, is unable and inadequate to identify, locate, and quantify defects in sanitary

sewers that potentially cause infiltration.

In addition to becoming a recommended pre-rehabilitation assessment tool, added benefit exists as a post-rehabilitation assessment tool

to certify sewer repairs, relining, and replacements, as “leak free.”

41

Findings & Conclusions