Top Banner
Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013
19

Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

Dec 24, 2015

Download

Documents

Jacob McDonald
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

Beam Secondary Shower Acquisition System: Cables Measurements

Student MeetingJose Luis Sirvent

PhD. Student22/07/2013

Page 2: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 1st Experiment layout:

– Frequency Response (Bode Plot ‘Magnitude’)

– Phase displacement (Bode Plot ‘Angle’)

LeCroy Scope

Adapters BNC-N

BNCCh1

50 ohm

Splitter N-2xBNC50 ohm

Loop (double Female)N-Connector

10 ns

10 ns

8 ns

Func. GeneratorBNCCh2

50 ohm

CK502 x 88 m = 176m

Page 3: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 1st Experiment :

– Frequency Response (Bode Plot ‘Magnitude’)• Measuring the ratio V2rms/V1rms at different frequencies

Page 4: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.

Very good agreement Pspice model: Fits well with 176m!!

Analitical functions:Where :C(l), L(l) and Rac(l,f), Gac(l,f)Values of Rac and Gac have been calculated from:http://issues.cern.ch/browse/BIWS-422

Page 5: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 2nd Experiment layout:

– Pulse distortion (Integrator effect)

– Step response (Low-pass filter)

LeCroy Scope

Adapters SMA-N

SMA-BNCCh1

50 ohm

Splitter SMA-2xSMA

50 ohm

Loop (double Female)N-Connector

4 ns

4 ns

8 ns

Pulse GeneratorSMA-BNC

Ch250 ohm

CK502 x 125 m

Page 6: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 2nd Experiment (lab testing): Equipment works well, only delay of 8ns

4 ns

4 ns

8 ns

CK 50 Cable Connection

-PicoSecond 2600C:• Pulse generator 1 - 100ns• Selectionable delay• Repetition Rate 1-100KHz• Vo 45V (-70dB) • Zo 50 ohm

-LeCroy Scope:• Sampling Freq 5Gsps• Scale 2ns/div• Zin 50 ohm

-Testing pulses characteristics:• Rise time 419ps• Fall time 837ps• Pulse width700ps• System delay 8ns

Page 7: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 2nd Experiment (Pulse distortion with Square pulse):

Square pulse ~4ns:

• Rise: 407ps 596ps• Falling: 876ps 3.436ns• Width: 2.464ns 3.298ns

• Whole Pulse: 3.747ns 7.330ns (Δ195%)• Attenuation: 3V 1.75V (-4.68dB)

*Yellow: Input*Pink: Output

Page 8: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 2nd Experiment (Pulse distortion with ~1.5ns pulse):

Square pulse ~1.5ns:

• Rise: 378ps 606ps• Falling: 860ps 4.375ns• Width: 763ns 1.369ns

• Whole Pulse: 2.001ns 6.350ns (Δ317%)• Attenuation: 2.75V 1V (-8.7dB)

*Yellow: Input*Pink: Output

Beware the long tails!!

25ns

Page 9: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 2nd Experiment (Step Response & System Identification):

Matlab

System IdentificationToolbox

Arxqs model fits 94.64%!!

Delay = 759ns – 8ns (probe) = 751ns

Page 10: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• Comparison of the Matlab model TF(f)

Page 11: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• Comparison of the Matlab model TF(f)

Matlab model (arxqs)

Pspice model (Tlossy)

Page 12: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• 3rd Experiment layout:

– A) Cable noise measurement (Noise normal distribution & Noise Frequency Spectrum)• Usage of 2 sets of data at different sampling frequency: 500Mhz & 5Ghz

LeCroy Scope

Adapter BNC-N

BNCCh1

50 ohm

Loop (double Female)N-Connector

10 ns

BNCCh2

50 ohm

Load50 ohm

CK502 x 88 m = 176m

Page 13: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Noise Frequency Spectrum Fs= 500Mhz)

• Set 1: 10 Segments of 5ms recorded at 500Mhz with only scope loaded • Set 2: 10 Segments of 5ms recorded at 500Mhz with cable loaded• Extraction of FFT 1 – 250Mhz for each segment measured in set 1 and averages of FFT• Extraction of FFT 1 – 250Mhz for each segment measured in set 2 and averages of FFT

FM Radio Stations& TV

AM Radio Stations& Others

A

B

Page 14: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Noise Frequency Spectrum Fs= 5Ghz)

• Set 1: 10 Segments of 500us recorded at 5Ghz with only scope loaded • Set 2: 10 Segments of 500us recorded at 5Ghz with cable loaded• Extraction of FFT 1 – 2.5Ghz for each segment measured in set 1 and averages of FFT• Extraction of FFT 1 – 2.5Ghz for each segment measured in set 2 and averages of FFT

TV Stations GSM-900 GSM-1800WI-FI

C

D

Page 15: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Noise Frequency Spectrum Fs= 500Mhz & 5Ghz )

• A look in detail (Most important contribution 330KHz!!)

300KHz

1.67GHz750MHz

167MHzA B

C D

Page 16: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Noise Frequency Spectrum Fs= 500Mhz & 5Ghz )

• A look in semi-logaritmic scale (Easier to see that the most important contribution is at 330KHz!!)

Page 17: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Noise Frequency Spectrum Fs= 500Mhz)

1.23Khz

19.6Khz

330Khz

Page 18: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Amplitude distribution at Fs= 500Mhz)

Page 19: Beam Secondary Shower Acquisition System: Cables Measurements Student Meeting Jose Luis Sirvent PhD. Student 22/07/2013.

1. Cable measurements campaign.• A) Cable noise measurement (Amplitude distribution at Fs= 5Ghz)