Pressure, Differential Pressure, Flow, Level, Water Quality, Valve, Weather, Structure, Analog and Digital I/O Auto Data Collection, Cloud Storage,Operation and Monitoring Anytime and Anywhere
Cellular/WiFi/RS485Wireless Transmitter & Data Logger
Battery & Solar Powered
■ Battery Powered, 5 Year Continuous Operation for Hourly Data Upload per Day■ IP68 Continuous Submersible to 5 m of water, Solution without Cabinet■ -30~85°C Operating Temperature, 0~100% RH Operating Humidity ■ Cellular, WiFi or RF Communication■ Simultaneous Acquisition of Multiple Process Signals including Pressure Sensor, 2 Digital Analyzers and Transmitters, and I/O Module with 2DI, 2AI■ 1 Million Data Values of Log, 3 Year Storage Capacity at Every 30 min Log ■ 0.01 sec Transient Pressure Auto Detection and Data Logging■ Peer to Peer Communication for I/O Exchange■ Standard Modbus RTU Protocol■ Integral FTP Protocal, Directly Upload Data to End User FTP Server■ Seamless SCADA Software and Database Connectivity via OPC Server ■ Web Configuration, Operation,Monitoring, Alarm, Control and Data Analysis Software Service
RoHS
OutstandingAward
3Years Warranty
SMA
RT WATER SOLUTIONS
MADE IN TAIWAN(R.O
.C)
ECO Series
+75°C-25°C
WIDETEMPERATURE
ULTRA LOWPOWER
GOOGLEEARTH
100%
UVRESISTANT
SECURITYLOCK
SOLARPOWER
LOG
SURGEPRESSURE
WIRELESSNETWORK
IFTHENELSE
CONTROLRULES
MULTIPLEI/O
MULTIPLESENSORS
AlarmProfile
SMSMESSAGE
DATAQA/QC
144.9144.9 145
8.118.118.11
STATISTICS ANALYSIS
DATALOG
OPCSERVER
BATTERYOPERATION
ALARM GPS POSITION
GPRSNETWORK
GPRS
IP68PROTECT
RTU Controller, Data Logger, Device Gateway, Wireless Transmitter, Smart Meter Reader, Digital Transmitter
I/O Signal Processing, Data Acquisition, Data Logging, Cellular/ Wireless Communication, Data Monitoring, Alarming, Analysis and Control
The ECO series cellular/WiFi is a compact-sized, simple, highly reliable and cost-effective wireless transmitter and data logger. It is easy to be deployed across a wide range of water and wastewater applications, such as hydrants, manholes, meter vaults, pump stations, bunkers, etc.
Built-in pressure, I/O module, cellular, WiFi, GPS, barometer and RS485 modules. The RS485 port is able to connect level, water quality digital transmitter or Modbus RTU device.
Ultra low power consumption to ensure battery or solar powered for 10 years continuous operation.
Housing in a robust IP68 water submersible enclosure, the products are perfectly used in frequently flood underground chamber, harsh temperature and humidity outdoor environment.
1
Features
►Completely Self Contained
■ 3G/GPRS/CDMA five band 800/850/1700/1900/2100 MHz global coverage cellular communication■ License-free 2.4 GHz WiFi network communication■ Integral 10 years long life replaceable Lithium battery to sustain 5 years continuous operation for hourly data upload per day■ Optimized solar power module, solar panel and rechargeable lithium battery for 3 years continuous operation at every 5 minutes data upload per day
►Robust Outdoor, Compact Construction
■ IP68 continuous submersible to 5 meters of water ■ Operating temperature: -30 to 85 deg C; operating humidity: 0~100% RH
►High Capacity and Flexibility
■ 3 signal inputs: pressure module, RS485, I/O module■ 3 Communication: cellular, WiFi, RS485■ Built-in I/O Module: 2 digital inputs, 2 analog inputs■ Connect SMR I/O modules up to 4 digital/analog inputs■ 4 choices of Power supply: external power, inernal battery, solar power and external battery box■ RS485 communication up to 2 SMR digital analyzers and transmitters and 1 Modbus RTU device such as flow meter or PLC■ 1,000,000 data values of log
►High Accuracy and Reliability
■ Accuracy of pressure sensor: up to ±0.1% FS ■ Accuracy of analog input: ±0.025% FS ■ Pressure sensor with temperature compensation■ Barometer for level compensation■ Superior communication performance in underground chamber environment
►Transient Pressure Detection and Data Logging
■ 0.01 sec transient pressure auto detection and alarming for water hammer, pipeline rupture, leakage, sudden change in demand, negative pressure, pump and valve malfunction, faulty operation, etc.■ 0.01 sec high speed transient pressure wave logging
►Quick Installation
■ Quick fit SS316 pressure coupler■ IP68 connectors for quick fit connection
►Easy Setup
■ Cellular/WiFi over the air remote configuration download■ Setup operation parameters, monitor system, I/O, cellular/WiFi/GPS signal and calibrate sensor via AQCFG software■ 2.4" LCD display of sensor value, I/O status, system status, units
►Smart Function
■ Scheduled and alarm communication: data collection, SMS, alarm notification, data upload, setting download, store and forward; upload data more frequently while alarming■ Log: periodical, event, alarm, transient pressure■ Configurable alarm (HH, H, L, LL) and actions including SMS, alarm log ■ Peer to peer communication for I/O and data exchange
►Auto Data Collection, Cloud Storage, WEB Operation and Monitoring
■ Automatic registration and synchronization of device ID, serial number, alias, location and operation settings ■ Automatic GPS locating, time synchronization and coordinates logging with process data■ Web configuration, operation, monitoring, alarm, control, Google Map display, statistical analysis, transient pressure analysis, trend, bar graph and tabular report functions ■ Central communication server and application programming library for field device data collection and central communication integration■ SQL and mySQL database connection for development of application software■ Directly upload CSV format log file to end user FTP server■ Seamless SCADA software and database connectivity via OPC server■ Anytime and anywhere internet operation and monitoring
►Security
■ Login password access protection■ 128 bits cellular and WiFi encryption to prevent unauthorized access■ GPS location deviation anti-theft alarm■ Safety cover and lock■ CE, FCC certification
■ CPU: 32 bits■ Memory: solid state, non-volatile flash, size: 16 MB ; rotating, no log or setting data loss after power failure■ Real-time clock: type: crystal controlled calendar clock with leap year adjustment; accuracy: 10 seconds per month; GPS and NTP server auto time synchronization, accuracy: 1 ms(GPS), 1~3 sec(NTP) ■ Environment: protection: IP68, continuous submersible to 5 meters of water; operating temperature: -30~85 °C; operating humidity: 0 ~100 % RH■ Safety: CE, FCC
Function
■ Data Collection: SMR digital transmitter, flow meter or Modbus RTU device■ Communication: data transmittion; SMS alarm notification; data upload/ download; store and forward; FTP ■ Log: 1,000,000 records, rotating store; periodical; event; alarm; transient pressure■ Alarm: HH, H, L, LL; alarm action: SMS, alarm log
■ 2.4” with back light ■ Display: sensor and transmitter values, I/O status, system and communication status, unit ■ 3 numbers: 9 digits,41⁄2 digits,11⁄2 digits ■ Dimensions: 60(W) x 34(H)
Housing
■ Engineering ABS plastics with polycarbonate■ Dimensions: Φ 110 x120 mm■ Weight: approx. 900 g
Power
►External Power ■ Voltage: 9-18 V DC ±10%, 1.5 A ■ Surge protection: 4000 V DC ■ ESD line protection:15 KV DC
►Internal Battery ■ Non-rechargeable 3.6 V DC 28 AH lithium cell ■ Life: 10 years
►Internal Battery ■ Rechargeable 3.6 V DC 10 AH lithium cell ■ Life: minimum 300 charge/discharge cycles
► Solar Power ■ Type: 6 V DC, 3 W solar panel■ Rechargeable 3.6 V DC 10 AH lithium cell ■ Life: minimum 300 charge/discharge cycles
►External Battery Box: ■ Rechargeable 3.6 V DC 60 AH lithium cell ■ Life:minimum 300 times charge/discharge cycles
3
Specification
ECO Series
System Configuration Module (Port 0)
RS485 module■ System configuration and data upload/download■ 115,200 bps, 8 bits, no parity, 1 stop bit■ Surge protection: 4000 V DC■ Protocol: Modbus RTU or proprietary device drivers
Device Communication Module (Port 1)
RS485 module ■ Device data collection, connecting up to 2 SMR digital analyzers and transmitters and 1 Modbus RTU serial device■ 19,200bps, 8 bits, no parity, 1 stop bit■ Surge protection: 4000 V DC■ Protocol: Modbus RTU or proprietary device drivers■ Digital Transmitter : Pressure, differential pressure, level, free chlorine, PH, ORP, temperature, conductivity, resistivity, dissolved oxygen, turbidity, salinity, suspended solid, ammonium, COD, humidity, differential pressure, barometer, analog input, counter input, digital input, vibration wire input, valve position, inclinometer, vibration
I/O Module (Port 2)
►Digital inputs ■ number of channels: 2 counter or state inputs
■ Type: 3.5-12 V DC or dry contact single ended input ■ Maximum operating frequency: 1 KHz ■ Minimum pulse width: 10 msec ■ Surge protection: 4000 V DC
►Analog inputs ■ Number of channels: 2 ■ Resolution: 15 bits ■ Accuracy: 0.025% FS ■ Signals: 0~1 V DC, 0~10 V DC, 4~20 mA ■ Surge protection: 4000 V DC
Cellular Module None GSM/GPRS 3GCDMA Wireless ModuleNoneWiFiGPS Module None Add-on Barometer Module None Add-on LCD Display ModuleNoneMetric UnitBritish Unit PowerExternal Power (No battery) Internal Battery (3.6 V DC 28 AH, Non-rechargeable)Internal Battery (3.6 V DC 10 AH, Rechargeable)Solar Panel(3W 6 V DC 10 AH, Rechargeable)External Battery Box (3.6 V DC 60 AH, Rechargeable)Port1 (Device Communication Module)NoneRS485DriverNoneCustomer SpecifyPort2 (I/O Module)NoneAdd-onAI SignalNone4~20 mA0~1 V DC0~10 V DCPort3 (Pressure Module) NoneAdd-on(1/8” quick fit coupler)Range(Kgf/cm²)None0~10~100~200~50~150~35Type None AbsoluteGaugeAccuracyNone0.25% FS0.1% FS Transient Pressure Detection Module NoneAdd-onHousingNoneEngineering plastic(integral antenna)Engineering plastic(external antenna)
01
01
0123
01
Model No: ECO- -1
01234
01
012
012
012
01
01
Note:1. It is not able to select both cellular and WiFi module at the same time.2. The product is customizable designed with different kinds of sensors, I/O modules and devices protocols upon request.
0123456
01
--2 -3
01
0 0
0123
012
Digital Analyzers and Transmitters
Optionals Ordering
Order No. DescriptionSMR01-1 Digital pressure transmitter (0~1 Kgf/cm²)SMR01-2 Digital pressure transmitter (0~5 Kgf/cm²)SMR01-3 Digital pressure transmitter (0~10 Kgf/cm²)SMR01-4 Digital pressure transmitter (0~15 Kgf/cm²)SMR01-5 Digital pressure transmitter (0~20 Kgf/cm²)SMR01-6 Digital pressure transmitter (0~35 Kgf/cm²)SMR01-7 Digital pressure transmitter (0~60 Kgf/cm²)SMR02-1 Digital hydrostatic level transmitter (0~10 m) SMR02-2 Digital hydrostatic level transmitter (0~50 m)SMR02-3 Digital hydrostatic level transmitter (0~100 m)SMR02-4 Digital hydrostatic level transmitter (0~200 m)SMR02-5 Digital hydrostatic level transmitter (0~350 m)SMR02-6 Digital hydrostatic level transmitter (0~600 m)SMR03-1 Digital free chlorine analyzer (0~5 ppm) SMR03-2 Digital free chlorine and pH analyzer (0~10 ppm) SMR04-1 Digital pH and temperature analyzer (0~14 pH)SMR05-1 Digital ORP(Redox) and temperature analyzer (-1000~1000 mV) SMR06-1 Digital temperature transmitter (pt100)(-40~85 °C)SMR06-2 Digital temperature transmitter (pt100)(-40~350 °C)SMR07-1 Digital conductivity and temperature analyzer (0 ~ 5 ms/cm)SMR07-2 Digital conductivity and temperature analyzer (0 ~ 50 ms/cm)SMR08-1 Digital resistivity and temperature analyzer (0~20 MΩ)SMR09-1 Digital dissolved oxygen and temperature analyzer
(electrochemical)(0~20 ppm)
SMR09-2 Digital dissolved oxygen analyzer (optical)(0.00~20.00 ppm)SMR10-1 Digital turbidity analyzer (0~10 NTU)SMR10-2 Digital turbidity analyzer (0~100 NTU)SMR10-3 Digital turbidity analyzer (0~1000 NTU)SMR10-4 Digital turbidity analyzer (0~4000 NTU)SMR11-1 Digital salinity and temperature analyzer (0~100 ppt)SMR12-1 Digital suspended solid analyzer (0~100 ppm)SMR12-2 Digital suspended solid analyzer (0~1000 ppm)SMR13-1 Digital humidity transmitter (0 ~ 100% RH; -40~85 °C) SMR14-1 Digital differential pressure transmitter (0~0.05 Kgf/cm²)SMR14-2 Digital differential pressure transmitter (0~0.25 Kgf/cm²)SMR14-3 Digital differential pressure transmitter (0~0.5 Kgf/cm²)SMR14-4 Digital differential pressure transmitter (0~1 Kgf/cm²)SMR14-5 Digital differential pressure transmitter (0~5 Kgf/cm²)SMR14-6 Digital differential pressure transmitter (0~20 Kgf/cm²)SMR15-1 Digital barometer transmitter (-40~85 °C; 10~1300 mbar)SMR16-1 Analog input transmitter (4-20 mA, 2 channels)SMR16-2 Analog input transmitter (4-20 mA, 4 channels)SMR16-3 Analog input transmitter (4-20 mA, 8 channels)SMR17-1 Counter input transmitter (2 channels)SMR17-2 Counter input transmitter (4 channels)SMR17-3 Counter input transmitter (8 channels)SMR17-4 Digital input transmitter (2 channels)SMR17-5 Digital input transmitter (4 channels)SMR17-6 Digital input transmitter (8 channels)SMR18-1 Digital output transmitter (2 channels)SMR18-2 Digital output transmitter (4 channels)SMR18-3 Digital output transmitter (8 channels)SMR19-1 Vibration wire input transmitter(1 channel)SMR19-2 Vibration wire input transmitter(2 channels)SMR19-3 Vibration wire input transmitter(4 channels)SMR20-1 Digital gate position transmitter (0~100%)SMR21-1 Digital inclinometer analyzer (±15 °)(vertical)SMR21-2 Digital inclinometer analyzer (±15 °)(horizontal)SMR22-1 Digital vibration and temperature analyzer (±25 mm/s)SMR23-1 Digital ammonium and temperature analyzer (0.1~1,000 ppm)SMR24-1 Digital wind direction transmitter (0~360°)SMR25-1 Digital COD and temperature analyzer (0~100 ppm)