Top Banner
7/29/2019 BatranaDeveloper_MeasLayout_9_0 http://slidepdf.com/reader/full/batranadevelopermeaslayout90 1/222 BSS-IM Version: 9_0 scannerObjectClass: /BSS/SCANBSC (0) Meas Name: (0,0)-- sINHOBSC-- Successful Internal Handovers per BSC per cause Meas Set: 0 Counter Id Name Unit Type Size Scale Digit Accuracy 0 Uplink Quality N LONG 4 1 0 1 Downlink Quality N LONG 4 1 0 2 Uplink Strength N LONG 4 1 0 3 Downlink Strength N LONG 4 1 0 4 Distance (MS-BTS) N LONG 4 1 0 5 Better Cell (PBGT) N LONG 4 1 0 6 Directed Retry N LONG 4 1 0 7 Inner to Complete Area (concentric cell) N LONG 4 1 0 8 Complete to Inner Area (concentric cell) N LONG 4 1 0 9 Near to Far Area (extended cell) N LONG 4 1 0 10 Far to Near Area (extended cell) N LONG 4 1 0 11 Traffic N LONG 4 1 0 12 Fast Uplink N LONG 4 1 0 13 TCH/H to TCH/F due to AMR N LONG 4 1 0 14 TCH/F to TCH/H due to AMR N LONG 4 1 0 15 Compression HO from FR/EFR to HR N LONG 4 1 0 16 Decompression HO from HR to FR/EFR N LONG 4 1 0 17 Others N LONG 4 1 0 Meas Name: (0,13)-- bSCPRCLD-- Measurement of BSC Meas Set: 0
222

BatranaDeveloper_MeasLayout_9_0

Apr 14, 2018

Download

Documents

Neeraj Yadav
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 1/222

BSS-IM Version: 9_0

scannerObjectClass: /BSS/SCANBSC (0)

Meas

Name:

(0,0)-- sINHOBSC--

Successful Internal

Handovers per BSC per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N LONG 4 1 01 Downlink Quality N LONG 4 1 0

2 Uplink Strength N LONG 4 1 0

3 Downlink Strength N LONG 4 1 0

4 Distance (MS-BTS) N LONG 4 1 0

5 Better Cell (PBGT) N LONG 4 1 0

6 Directed Retry N LONG 4 1 0

7Inner to Complete Area

(concentric cell)N LONG 4 1 0

8 Complete to Inner Area(concentric cell)

N LONG 4 1 0

9Near to Far Area (extendedcell)

N LONG 4 1 0

10Far to Near Area (extended

cell)N LONG 4 1 0

11 Traffic N LONG 4 1 0

12 Fast Uplink N LONG 4 1 0

13 TCH/H to TCH/F due to AMR N LONG 4 1 0

14 TCH/F to TCH/H due to AMR N LONG 4 1 0

15Compression HO from FR/EFR

to HRN LONG 4 1 0

16Decompression HO from HR

to FR/EFRN LONG 4 1 0

17 Others N LONG 4 1 0

Meas

Name:

(0,13)-- bSCPRCLD--

Measurement of BSCMeas Set: 0

Page 2: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 2/222

Processor load

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy0 Prime Time MPCC % WORD 2 100 2

1 Total Time MPCC % WORD 2 100 2

28 Max Total Time MPCC % WORD 2 100 2

2 Prime Time TDPC % WORD 2 100 2

3 Total Time TDPC % WORD 2 100 2

29 Max Total Time TDPC % WORD 2 100 2

4 Prime Time PCU0 % WORD 2 100 2

5 Total Time PCU0 % WORD 2 100 2

30 Max Total Time PCU0 % WORD 2 100 2

6 Prime Time PCU1 % WORD 2 100 2

7 Total Time PCU1 % WORD 2 100 2

31 Max Total Time PCU1 % WORD 2 100 2

8 Prime Time PCU2 % WORD 2 100 2

9 Total Time PCU2 % WORD 2 100 2

32 Max Total Time PCU2 % WORD 2 100 2

10 Prime Time PCU3 % WORD 2 100 2

11 Total Time PCU3 % WORD 2 100 2

33 Max Total Time PCU3 % WORD 2 100 2

12 Prime Time PCU4 % WORD 2 100 2

13 Total Time PCU4 % WORD 2 100 2

34 Max Total Time PCU4 % WORD 2 100 2

14 Prime Time PCU5 % WORD 2 100 2

15 Total Time PCU5 % WORD 2 100 2

35 Max Total Time PCU5 % WORD 2 100 2

16 Prime Time PCU6 % WORD 2 100 217 Total Time PCU6 % WORD 2 100 2

36 Max Total Time PCU6 % WORD 2 100 2

18 Prime Time PCU7 % WORD 2 100 2

19 Total Time PCU7 % WORD 2 100 2

37 Max Total Time PCU7 % WORD 2 100 2

20 Prime Time PCU8 % WORD 2 100 2

21 Total Time PCU8 % WORD 2 100 2

Page 3: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 3/222

38 Max Total Time PCU8 % WORD 2 100 2

22 Prime Time PCU9 % WORD 2 100 2

23 Total Time PCU9 % WORD 2 100 2

39 Max Total Time PCU9 % WORD 2 100 2

24 Prime Time PCU10 % WORD 2 100 2

25 Total Time PCU10 % WORD 2 100 2

40 Max Total Time PCU10 % WORD 2 100 2

26 Prime Time PCU11 % WORD 2 100 2

27 Total Time PCU11 % WORD 2 100 2

41 Max Total Time PCU11 % WORD 2 100 2

Meas

Name:

(0,13)-- bSCPRCLD--

Measurement of BSC

Processor load

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

42 Total Time MCP % WORD 2 100 2

78 Max Total Time MCP % WORD 2 100 2

43 Total Time APM % WORD 2 100 2

79 Max Total Time APM % WORD 2 100 2

51 Total Time SHELF1/SMAC0 % WORD 2 100 2

87Max Total Time

SHELF1/SMAC0% WORD 2 100 2

52 Total Time SHELF1/SMAC1 % WORD 2 100 2

88Max Total Time

SHELF1/SMAC1% WORD 2 100 2

53 Total Time LIET0 % WORD 2 100 2

89 Max Total Time LIET0 % WORD 2 100 2

54 Total Time LIET1 % WORD 2 100 290 Max Total Time LIET1 % WORD 2 100 2

55 Total Time LIET2 % WORD 2 100 2

91 Max Total Time LIET2 % WORD 2 100 2

56 Total Time LIET3 % WORD 2 100 2

92 Max Total Time LIET3 % WORD 2 100 2

57 Total Time LIET4 % WORD 2 100 2

93 Max Total Time LIET4 % WORD 2 100 2

Page 4: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 4/222

58 Total Time LIET5 % WORD 2 100 2

94 Max Total Time LIET5 % WORD 2 100 2

59 Total Time LIET6 % WORD 2 100 2

95 Max Total Time LIET6 % WORD 2 100 2

60 Total Time LIET7 % WORD 2 100 2

96 Max Total Time LIET7 % WORD 2 100 2

61 Total Time LIET8 % WORD 2 100 2

97 Max Total Time LIET8 % WORD 2 100 2

5 Total Time PCU0 % WORD 2 100 2

30 Max Total Time PCU0 % WORD 2 100 2

7 Total Time PCU1 % WORD 2 100 231 Max Total Time PCU1 % WORD 2 100 2

9 Total Time PCU2 % WORD 2 100 2

32 Max Total Time PCU2 % WORD 2 100 2

11 Total Time PCU3 % WORD 2 100 2

33 Max Total Time PCU3 % WORD 2 100 2

13 Total Time PCU4 % WORD 2 100 2

34 Max Total Time PCU4 % WORD 2 100 2

15 Total Time PCU5 % WORD 2 100 2

35 Max Total Time PCU5 % WORD 2 100 2

17 Total Time PCU6 % WORD 2 100 2

36 Max Total Time PCU6 % WORD 2 100 2

19 Total Time PCU7 % WORD 2 100 2

37 Max Total Time PCU7 % WORD 2 100 2

21 Total Time PCU8 % WORD 2 100 2

38 Max Total Time PCU8 % WORD 2 100 2

23 Total Time PCU9 % WORD 2 100 2

39 Max Total Time PCU9 % WORD 2 100 2

Meas

Name:

(0,13)-- bSCPRCLD--

Measurement of BSC

Processor load

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

42 Total Time MCP % WORD 2 100 2

78 Max Total Time MCP % WORD 2 100 2

Page 5: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 5/222

43 Total Time APM % WORD 2 100 2

79 Max Total Time APM % WORD 2 100 2

44 Total Time APD1 % WORD 2 100 2

80 Max Total Time APD1 % WORD 2 100 2

45 Total Time APD1 % WORD 2 100 2

81 Max Total Time APD2 % WORD 2 100 2

46 Total Time APD1 % WORD 2 100 2

82 Max Total Time APD3 % WORD 2 100 2

47 Total Time APD1 % WORD 2 100 2

83 Max Total Time APD4 % WORD 2 100 2

48 Total Time APD1 % WORD 2 100 284 Max Total Time APD5 % WORD 2 100 2

49 Total Time SHELF0/SMAC0 % WORD 2 100 2

85Max Total Time

SHELF0/SMAC0% WORD 2 100 2

50 Total Time SHELF0/SMAC1 % WORD 2 100 2

86Max Total Time

SHELF0/SMAC1% WORD 2 100 2

51 Total Time SHELF1/SMAC0 % WORD 2 100 2

87 Max Total TimeSHELF1/SMAC0

% WORD 2 100 2

52 Total Time SHELF1/SMAC1 % WORD 2 100 2

88Max Total Time

SHELF1/SMAC1% WORD 2 100 2

53 Total Time LIET0 % WORD 2 100 2

89 Max Total Time LIET0 % WORD 2 100 2

54 Total Time LIET1 % WORD 2 100 2

90 Max Total Time LIET1 % WORD 2 100 2

55 Total Time LIET2 % WORD 2 100 2

91 Max Total Time LIET2 % WORD 2 100 2

56 Total Time LIET3 % WORD 2 100 2

92 Max Total Time LIET3 % WORD 2 100 2

57 Total Time LIET4 % WORD 2 100 2

93 Max Total Time LIET4 % WORD 2 100 2

58 Total Time LIET5 % WORD 2 100 2

94 Max Total Time LIET5 % WORD 2 100 2

Page 6: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 6/222

59 Total Time LIET6 % WORD 2 100 2

95 Max Total Time LIET6 % WORD 2 100 2

60 Total Time LIET7 % WORD 2 100 2

96 Max Total Time LIET7 % WORD 2 100 2

61 Total Time LIET8 % WORD 2 100 2

97 Max Total Time LIET8 % WORD 2 100 2

5 Total Time PCU0 % WORD 2 100 2

30 Max Total Time PCU0 % WORD 2 100 2

7 Total Time PCU1 % WORD 2 100 2

31 Max Total Time PCU1 % WORD 2 100 2

9 Total Time PCU2 % WORD 2 100 232 Max Total Time PCU2 % WORD 2 100 2

11 Total Time PCU3 % WORD 2 100 2

33 Max Total Time PCU3 % WORD 2 100 2

13 Total Time PCU4 % WORD 2 100 2

34 Max Total Time PCU4 % WORD 2 100 2

15 Total Time PCU5 % WORD 2 100 2

35 Max Total Time PCU5 % WORD 2 100 2

17 Total Time PCU6 % WORD 2 100 2

36 Max Total Time PCU6 % WORD 2 100 2

19 Total Time PCU7 % WORD 2 100 2

37 Max Total Time PCU7 % WORD 2 100 2

21 Total Time PCU8 % WORD 2 100 2

38 Max Total Time PCU8 % WORD 2 100 2

23 Total Time PCU9 % WORD 2 100 2

39 Max Total Time PCU9 % WORD 2 100 2

25 Total Time PCU10 % WORD 2 100 2

40 Max Total Time PCU10 % WORD 2 100 2

27 Total Time PCU11 % WORD 2 100 2

41 Max Total Time PCU11 % WORD 2 100 2

62 Total Time PCU12 % WORD 2 100 2

98 Max Total Time PCU12 % WORD 2 100 2

63 Total Time PCU13 % WORD 2 100 2

99 Max Total Time PCU13 % WORD 2 100 2

64 Total Time PCU14 % WORD 2 100 2

Page 7: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 7/222

100 Max Total Time PCU14 % WORD 2 100 2

65 Total Time PCU15 % WORD 2 100 2

101 Max Total Time PCU15 % WORD 2 100 2

66 Total Time PCU16 % WORD 2 100 2

102 Max Total Time PCU16 % WORD 2 100 2

67 Total Time PCU17 % WORD 2 100 2

103 Max Total Time PCU17 % WORD 2 100 2

68 Total Time PCU18 % WORD 2 100 2

104 Max Total Time PCU18 % WORD 2 100 2

69 Total Time PCU19 % WORD 2 100 2

105 Max Total Time PCU19 % WORD 2 100 270 Total Time PCU20 % WORD 2 100 2

106 Max Total Time PCU20 % WORD 2 100 2

71 Total Time PCU21 % WORD 2 100 2

107 Max Total Time PCU21 % WORD 2 100 2

72 Total Time PCU22 % WORD 2 100 2

108 Max Total Time PCU22 % WORD 2 100 2

73 Total Time PCU23 % WORD 2 100 2

109 Max Total Time PCU23 % WORD 2 100 2

74 Total Time SDH0 % WORD 2 100 2

110 Max Total Time SDH0 % WORD 2 100 2

75 Total Time SDH1 % WORD 2 100 2

111 Max Total Time SDH1 % WORD 2 100 2

76 Total Time SDH2 % WORD 2 100 2

112 Max Total Time SDH2 % WORD 2 100 2

77 Total Time SDH3 % WORD 2 100 2

113 Max Total Time % WORD 2 100 2

Meas

Name:

(0,14)-- hOFITABS-- Total

number of Handover failures

Intra BSC

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Total number of Handover

failures Intra BSCN LONG 4 1 0

Page 8: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 8/222

Meas

Name:

(0,15)-- nRINHDFL--

Number of Inter BSC

Handover failures

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Inter BSC

Handover failuresN LONG 4 1 0

Meas

Name:

(0,16)-- rQIISHDO-- Number

of Requested Incoming

Intersystem Handover per

BSC

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Number of Requested

Incoming IntersystemHandover per BSC

N LONG 4 1 0

Meas

Name:

(0,17)-- uNIISHDO-- Number

of Unsuccessful Incoming

Intersystem Handover per

BSC

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Number of Unsuccessful

Incoming Intersystem

Handover per BSC

N LONG 4 1 0

Meas

Name:

(0,18)-- sUIISHDO-- Number

of Successful Incoming

Intersystem Handover per

BSC

Meas Set: 0

CounterId

Name Unit Type Size ScaleDigitAccuracy

0

Number of Successful

Incoming Intersystem

Handover per BSC

N LONG 4 1 0

Meas

Name:

(0,19)-- nPDTPCU-- Min,

max, mean number of used

PDTs per PCU

Meas Set: 0

Page 9: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 9/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Minimum number of usedPDT of PCU 0

N WORD 2 1 0

1Maximum number of used

PDT of PCU 0N WORD 2 1 0

2Mean number of used PDT of 

PCU 0N LONG 4 1000 2

3Minimum number of used

PDT of PCU 1N WORD 2 1 0

4Maximum number of usedPDT of PCU 1

N WORD 2 1 0

5Mean number of used PDT of 

PCU 1N LONG 4 1000 2

6Minimum number of used

PDT of PCU 2N WORD 2 1 0

7Maximum number of used

PDT of PCU 2N WORD 2 1 0

8Mean number of used PDT of 

PCU 2N LONG 4 1000 2

9Minimum number of used

PDT of PCU 3

N WORD 2 1 0

10Maximum number of usedPDT of PCU 3

N WORD 2 1 0

11Mean number of used PDT of 

PCU 3N LONG 4 1000 2

12Minimum number of usedPDT of PCU 4

N WORD 2 1 0

13Maximum number of used

PDT of PCU 4N WORD 2 1 0

14

Mean number of used PDT of 

PCU 4 N LONG 4 1000 2

15Minimum number of used

PDT of PCU 5N WORD 2 1 0

16Maximum number of used

PDT of PCU 5N WORD 2 1 0

17Mean number of used PDT of 

PCU 5N LONG 4 1000 2

18Minimum number of used

PDT of PCU 6N WORD 2 1 0

Page 10: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 10/222

19Maximum number of usedPDT of PCU 6

N WORD 2 1 0

20 Mean number of used PDT of PCU 6

N LONG 4 1000 2

21Minimum number of used

PDT of PCU 7N WORD 2 1 0

22Maximum number of used

PDT of PCU 7N WORD 2 1 0

23Mean number of used PDT of 

PCU 7N LONG 4 1000 2

24Minimum number of usedPDT of PCU 8

N WORD 2 1 0

25Maximum number of used

PDT of PCU 8N WORD 2 1 0

26Mean number of used PDT of 

PCU 8N LONG 4 1000 2

27Minimum number of used

PDT of PCU 9N WORD 2 1 0

28Maximum number of used

PDT of PCU 9N WORD 2 1 0

29Mean number of used PDT of 

PCU 9

N LONG 4 1000 2

30Minimum number of usedPDT of PCU 10

N WORD 2 1 0

31Maximum number of used

PDT of PCU 10N WORD 2 1 0

32Mean number of used PDT of PCU 10

N LONG 4 1000 2

33Minimum number of used

PDT of PCU 11N WORD 2 1 0

34

Maximum number of used

PDT of PCU 11 N WORD 2 1 0

35Mean number of used PDT of 

PCU 11N LONG 4 1000 2

Meas

Name:

(0,19)-- nPDTPCU-- Min,

max, mean number of used

PDTs per PCU

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 11: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 11/222

0Minimum number of usedPDT of PCU 0

N WORD 2 1 0

1 Maximum number of usedPDT of PCU 0

N WORD 2 1 0

2Mean number of used PDT of 

PCU 0N LONG 4 1000 2

3Minimum number of used

PDT of PCU 1N WORD 2 1 0

4Maximum number of used

PDT of PCU 1N WORD 2 1 0

5Mean number of used PDT of PCU 1

N LONG 4 1000 2

6Minimum number of used

PDT of PCU 2N WORD 2 1 0

7Maximum number of used

PDT of PCU 2N WORD 2 1 0

8Mean number of used PDT of 

PCU 2N LONG 4 1000 2

9Minimum number of used

PDT of PCU 3N WORD 2 1 0

10Maximum number of used

PDT of PCU 3

N WORD 2 1 0

11Mean number of used PDT of PCU 3

N LONG 4 1000 2

12Minimum number of used

PDT of PCU 4N WORD 2 1 0

13Maximum number of usedPDT of PCU 4

N WORD 2 1 0

14Mean number of used PDT of 

PCU 4N LONG 4 1000 2

15

Minimum number of used

PDT of PCU 5 N WORD 2 1 0

16Maximum number of used

PDT of PCU 5N WORD 2 1 0

17Mean number of used PDT of 

PCU 5N LONG 4 1000 2

18Minimum number of used

PDT of PCU 6N WORD 2 1 0

19Maximum number of used

PDT of PCU 6N WORD 2 1 0

Page 12: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 12/222

20Mean number of used PDT of PCU 6

N LONG 4 1000 2

21 Minimum number of usedPDT of PCU 7

N WORD 2 1 0

22Maximum number of used

PDT of PCU 7N WORD 2 1 0

23Mean number of used PDT of 

PCU 7N LONG 4 1000 2

24Minimum number of used

PDT of PCU 8N WORD 2 1 0

25Maximum number of usedPDT of PCU 8

N WORD 2 1 0

26Mean number of used PDT of 

PCU 8N LONG 4 1000 2

27Minimum number of used

PDT of PCU 9N WORD 2 1 0

28Maximum number of used

PDT of PCU 9N WORD 2 1 0

29Mean number of used PDT of 

PCU 9N LONG 4 1000 2

Meas

Name:

(0,19)-- nPDTPCU-- Min,max, mean number of used

PDTs per PCU

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Minimum number of used

PDT of PCU 0N WORD 2 1 0

1Maximum number of used

PDT of PCU 0N WORD 2 1 0

2

Mean number of used PDT of 

PCU 0 N LONG 4 1000 2

3Minimum number of used

PDT of PCU 1N WORD 2 1 0

4Maximum number of usedPDT of PCU 1

N WORD 2 1 0

5Mean number of used PDT of 

PCU 1N LONG 4 1000 2

6Minimum number of used

PDT of PCU 2N WORD 2 1 0

Page 13: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 13/222

7Maximum number of usedPDT of PCU 2

N WORD 2 1 0

8 Mean number of used PDT of PCU 2

N LONG 4 1000 2

9Minimum number of used

PDT of PCU 3N WORD 2 1 0

10Maximum number of used

PDT of PCU 3N WORD 2 1 0

11Mean number of used PDT of 

PCU 3N LONG 4 1000 2

12Minimum number of usedPDT of PCU 4

N WORD 2 1 0

13Maximum number of used

PDT of PCU 4N WORD 2 1 0

14Mean number of used PDT of 

PCU 4N LONG 4 1000 2

15Minimum number of used

PDT of PCU 5N WORD 2 1 0

16Maximum number of used

PDT of PCU 5N WORD 2 1 0

17Mean number of used PDT of 

PCU 5

N LONG 4 1000 2

18Minimum number of usedPDT of PCU 6

N WORD 2 1 0

19Maximum number of used

PDT of PCU 6N WORD 2 1 0

20Mean number of used PDT of PCU 6

N LONG 4 1000 2

21Minimum number of used

PDT of PCU 7N WORD 2 1 0

22

Maximum number of used

PDT of PCU 7 N WORD 2 1 0

23Mean number of used PDT of 

PCU 7N LONG 4 1000 2

24Minimum number of used

PDT of PCU 8N WORD 2 1 0

25Maximum number of used

PDT of PCU 8N WORD 2 1 0

26Mean number of used PDT of 

PCU 8N LONG 4 1000 2

Page 14: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 14/222

27Minimum number of usedPDT of PCU 9

N WORD 2 1 0

28 Maximum number of usedPDT of PCU 9

N WORD 2 1 0

29Mean number of used PDT of 

PCU 9N LONG 4 1000 2

30Minimum number of used

PDT of PCU 10N WORD 2 1 0

31Maximum number of used

PDT of PCU 10N WORD 2 1 0

32Mean number of used PDT of PCU 10

N LONG 4 1000 2

33Minimum number of used

PDT of PCU 11N WORD 2 1 0

34Maximum number of used

PDT of PCU 11N WORD 2 1 0

35Mean number of used PDT of 

PCU 11N LONG 4 1000 2

36Minimum number of used

PDT of PCU 12N WORD 2 1 0

37Maximum number of used

PDT of PCU 12

N WORD 2 1 0

38Mean number of used PDT of PCU 12

N LONG 4 1000 2

39Minimum number of used

PDT of PCU 13N WORD 2 1 0

40Maximum number of usedPDT of PCU 13

N WORD 2 1 0

41Mean number of used PDT of 

PCU 13N LONG 4 1000 2

42

Minimum number of used

PDT of PCU 14 N WORD 2 1 0

43Maximum number of used

PDT of PCU 14N WORD 2 1 0

44Mean number of used PDT of 

PCU 14N LONG 4 1000 2

45Minimum number of used

PDT of PCU 15N WORD 2 1 0

46Maximum number of used

PDT of PCU 15N WORD 2 1 0

Page 15: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 15/222

47Mean number of used PDT of PCU 15

N LONG 4 1000 2

48 Minimum number of usedPDT of PCU 16

N WORD 2 1 0

49Maximum number of used

PDT of PCU 16N WORD 2 1 0

50Mean number of used PDT of 

PCU 16N LONG 4 1000 2

51Minimum number of used

PDT of PCU 17N WORD 2 1 0

52Maximum number of usedPDT of PCU 17

N WORD 2 1 0

53Mean number of used PDT of 

PCU 17N LONG 4 1000 2

54Minimum number of used

PDT of PCU 18N WORD 2 1 0

55Maximum number of used

PDT of PCU 18N WORD 2 1 0

56Mean number of used PDT of 

PCU 18N LONG 4 1000 2

57Minimum number of used

PDT of PCU 19

N WORD 2 1 0

58Maximum number of usedPDT of PCU 19

N WORD 2 1 0

59Mean number of used PDT of 

PCU 19N LONG 4 1000 2

60Minimum number of usedPDT of PCU 20

N WORD 2 1 0

61Maximum number of used

PDT of PCU 20N WORD 2 1 0

62

Mean number of used PDT of 

PCU 20 N LONG 4 1000 2

63Minimum number of used

PDT of PCU 21N WORD 2 1 0

64Maximum number of used

PDT of PCU 21N WORD 2 1 0

65Mean number of used PDT of 

PCU 21N LONG 4 1000 2

66Minimum number of used

PDT of PCU 22N WORD 2 1 0

Page 16: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 16/222

67Maximum number of usedPDT of PCU 22

N WORD 2 1 0

68 Mean number of used PDT of PCU 22

N LONG 4 1000 2

69Minimum number of used

PDT of PCU 23N WORD 2 1 0

70Maximum number of used

PDT of PCU 23N WORD 2 1 0

71Mean number of used PDT of 

PCU 23N LONG 4 1000 2

MeasName:

(0,20)-- aBSCPTSM--

Number of Abnormal SCCPTermination by SMLC

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Abnormal SCCP

Termination by SMLCN LONG 4 1 0

Meas

Name:

(0,21)-- aTTLOCRQ--

Number of Attempted

Location Request

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Current geographic location N LONG 4 1 0

1Location assistance

information for the target MSN LONG 4 1 0

2

Deciphering keys for broadcast

assistance data for the target

MS

N LONG 4 1 0

3 Assisted GPS N LONG 4 1 0

Meas

Name:

(0,22)-- sUCLOCRS--

Number of successful

operation Location

Responses

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of successful operationLocation Responses

N LONG 4 1 0

Page 17: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 17/222

 

Meas

Name:

(0,23)-- uNSLOCRS--

Number of unsuccessful

operation Location

Responses per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Protocol Data Error N LONG 4 1 0

1 System Internal Failure N LONG 4 1 0

2 GPRS Applicable N LONG 4 1 0

3 Position Method Failure N LONG 4 1 0

4 Target MS Unreachable N LONG 4 1 0

5 Location Request Aborted N LONG 4 1 0

6 Inter-BSC Handover Ongoing N LONG 4 1 0

7 Intra-BSC Handover Complete N LONG 4 1 0

8 Congestion N LONG 4 1 0

Meas

Name:

(0,24)-- aBCLOCRQ--

Number of Abnormal

Condition Location Requests

per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Protocol Data Error N LONG 4 1 0

1 System Internal Failure N LONG 4 1 0

2 GPRS Applicable N LONG 4 1 0

3 Position Method Failure N LONG 4 1 0

4 Target MS Unreachable N LONG 4 1 0

5 Location Request Aborted N LONG 4 1 0

6 Inter-BSC Handover Ongoing N LONG 4 1 07 Intra-BSC Handover Complete N LONG 4 1 0

8 Congestion N LONG 4 1 0

Meas

Name:

(0,25)-- aTTLOCRP--

Number of Attempted Usage

Location Requests per

Positioning method

Meas Set: 0

Counter Name Unit Type Size Scale Digit

Page 18: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 18/222

Id Accuracy

0 Timing Advance N LONG 4 1 0

1 Mobile Assisted E-OTD N LONG 4 1 0

2 Mobile Based E-OTD N LONG 4 1 0

3 Mobile Assisted GPS N LONG 4 1 0

4 Mobile Based GPS N LONG 4 1 0

5 Conventional GPS N LONG 4 1 0

6 U-TDOA N LONG 4 1 0

MeasName:

(0,26)-- uATTLOCP--

Number of Unsuccessful

Attempted Usage LocationRequests per Positioning

method

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Timing Advance N LONG 4 1 0

1 Mobile Assisted E-OTD N LONG 4 1 0

2 Mobile Based E-OTD N LONG 4 1 0

3 Mobile Assisted GPS N LONG 4 1 0

4 Mobile Based GPS N LONG 4 1 0

5 Conventional GPS N LONG 4 1 0

6 U-TDOA N LONG 4 1 0

Meas

Name:

(0,27)-- aTTTAPOS--

Number of Attempted TA/E-

CITA Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of Attempted TA/E-CITA Positioning

N LONG 4 1 0

Meas

Name:

(0,28)-- sUCTAPOS--

Number of Successful TA/E-

CITA Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of Successful TA/E- N LONG 4 1 0

Page 19: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 19/222

CITA Positioning

Meas

Name:

(0,29)-- uNSTAPOS--Number of Unsuccessful

TA/E-CITA Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Unsuccessful TA/E-CITA Positioning

N LONG 4 1 0

Meas

Name:

(0,30)-- rESTAPOS--

Number of Reset TA/E-CITA

Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Reset TA/E-CITA

PositioningN LONG 4 1 0

Meas

Name:

(0,31)-- aTTAGRRC--

Number of Attempted A-

GPS/E-OTD RRLP

Command

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Initial command N LONG 4 1 0

1 Subsequent command N LONG 4 1 0

Meas

Name:

(0,32)-- sUCAGRRS--

Number of Successful A-

GPS/E-OTD RRLP Response

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0 Initial response N LONG 4 1 0

1 Subsequent response N LONG 4 1 0

Meas

Name:

(0,33)-- uNSAGRRP--

Number of Unsuccessful

Abort A-GPS/E-OTD RRLP

Procedure

Meas Set: 0

Counter Name Unit Type Size Scale Digit

Page 20: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 20/222

Id Accuracy

0Failure for other radio related

events

N LONG 4 1 0

1 Supervision Timer Expired N LONG 4 1 0

2 Inter-BSS handover N LONG 4 1 0

3Loss of signaling connection to

MSN LONG 4 1 0

Meas

Name:

(0,34)-- uNSRGRRP--

Number of Unsuccessful

Reject A-GPS/E-OTD RRLP

Procedure

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Congestion N LONG 4 1 0

1 Channel Mode not supported N LONG 4 1 0

2Positioning procedure not

supportedN LONG 4 1 0

3Failure for other radio related

eventsN LONG 4 1 0

4 Incorrect serving cell identity N LONG 4 1 0

5 BSSAP-LE Segmentation error N LONG 4 1 0

Meas

Name:

(0,35)-- rESAGRRP--

Number of Reset A-GPS/E-

OTD RRLP Procedure

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Intra-BSS handover N LONG 4 1 0

1Failure for other radio related

eventsN LONG 4 1 0

2 Supervision Timer Expired N LONG 4 1 0

3 Incorrect serving cell identity N LONG 4 1 0

Meas

Name:

(0,36)-- aTTUTREQ--

Number of Attempted U-

TDOA Requests

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 21: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 21/222

0Number of Attempted U-TDOA Requests

N LONG 4 1 0

Meas

Name:

(0,37)-- sUCUTDRS--

Number of Successful U-

TDOA Responses

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Successful U-

TDOA ResponsesN LONG 4 1 0

MeasName:

(0,38)-- uNSAUPOS--

Number of UnsuccessfulAbort U-TDOA Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Failure for other radio related

eventsN LONG 4 1 0

1 Supervision Timer Expired N LONG 4 1 0

2 Inter-BSS handover N LONG 4 1 0

3Loss of signaling connection to

MS

N LONG 4 1 0

Meas

Name:

(0,39)-- uNSRUPOS--

Number of Unsuccessful

Reject U-TDOA Positioning

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Congestion N LONG 4 1 0

1 Channel Mode not supported N LONG 4 1 0

2Positioning procedure not

supported N LONG 4 1 0

3Failure for other radio relatedevents

N LONG 4 1 0

4 Incorrect serving cell identity N LONG 4 1 0

5 BSSAP-LE Segmentation error N LONG 4 1 0

Meas

Name:

(0,40)-- rESUTPOS--

Number of Reset U-TDOAMeas Set: 0

Page 22: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 22/222

Positioning

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy0 Intra-BSS handover N LONG 4 1 0

1Failure for other radio relatedevents

N LONG 4 1 0

2 Supervision Timer Expired N LONG 4 1 0

3 Incorrect serving cell identity N LONG 4 1 0

Meas

Name:

(0,41)-- cNSPRCLD--

Central NS functionality

load

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Prime Time % WORD 2 100 2

1 Total Time % WORD 2 100 2

2 Max Total Time % WORD 2 100 2

Meas

Name:

(0,41)-- cNSPRCLD--

Central NS functionality

load

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

1 Total Time % WORD 2 100 2

2 Max Total Time % WORD 2 100 2

scannerObjectClass: /BSS/SCANBTS (1)

MeasName:

(1,0)-- mEBUSTCH-- Mean

number of busy TCHs

(Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N LONG 4 1000 2

1 TCH Halfrate N LONG 4 1000 2

Meas

Name:

(1,0)-- mEBUSTCH-- Mean

number of busy TCHsMeas Set: 1

Page 23: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 23/222

(Fullrate, Halfrate)

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy2 TCH Fullrate Inner N LONG 4 1000 2

3 TCH Halfrate Inner N LONG 4 1000 2

4 TCH Fullrate Complete N LONG 4 1000 2

5 TCH Halfrate Complete N LONG 4 1000 2

Meas

Name:

(1,0)-- mEBUSTCH-- Mean

number of busy TCHs

(Fullrate, Halfrate)

Meas Set: 2

CounterId

Name Unit Type Size Scale DigitAccuracy

6 TCH Fullrate Single Timeslot N LONG 4 1000 2

7 TCH Halfrate Single Timeslot N LONG 4 1000 2

8 TCH Fullrate Double Timeslot N LONG 4 1000 2

9 TCH Halfrate Double Timeslot N LONG 4 1000 2

Meas

Name:

(1,1)-- aALTCHTI-- All

available TCH Allocated

Time

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Total duration during thegranularity period all available

TCH/F are allocated

sec WORD 2 10 1

1Shortest time interval all

available TCH/F are allocatedsec WORD 2 10 1

2Longest time interval all

available TCH/F are allocatedsec WORD 2 10 1

3Total duration during thegranularity period all available

TCH/H are allocated

sec WORD 2 10 1

4Shortest time interval allavailable TCH/H are allocated

sec WORD 2 10 1

5Longest time interval all

available TCH/H are allocatedsec WORD 2 10 1

Meas (1,2)-- nRFLTCH-- Number Meas Set: 0

Page 24: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 24/222

Name: of lost Radio links while

using a TCH (Fullrate,

Halfrate)

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 T200 Expired TCH Fullrate N WORD 2 1 0

1

Unsolecited DM response,

multiple frame established

state TCH Fullrate

N WORD 2 1 0

2 Sequence error TCH Fullrate N WORD 2 1 0

3T_MSRFPCI expired TCH

FullrateN WORD 2 1 0

4Distance Limit Exceeded TCH

FullrateN WORD 2 1 0

5Handover Access Failure TCH

FullrateN WORD 2 1 0

6Radio Link Failure TCH

FullrateN WORD 2 1 0

7Remote Transcoder Failure

TCH FullrateN WORD 2 1 0

8 All other causes TCH Fullrate N WORD 2 1 0

9 T200 Expired TCH Halfrate N WORD 2 1 0

10

Unsolecited DM response,

multiple frame establishedstate TCH Halfrate

N WORD 2 1 0

11 Sequence error TCH Halfrate N WORD 2 1 0

12T_MSRFPCI expired TCH

HalfrateN WORD 2 1 0

13Distance Limit Exceeded TCH

HalfrateN WORD 2 1 0

14 Handover Access Failure TCHHalfrate N WORD 2 1 0

15Radio Link Failure TCH

HalfrateN WORD 2 1 0

16Remote Transcoder Failure

TCH HalfrateN WORD 2 1 0

17 All other causes TCH Halfrate N WORD 2 1 0

Meas (1,2)-- nRFLTCH-- Number Meas Set: 1

Page 25: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 25/222

Name: of lost Radio links while

using a TCH (Fullrate,

Halfrate)

Counter

IdName Unit Type Size Scale

Digit

Accuracy

18T200 Expired TCH Fullrate

Inner AreaN WORD 2 1 0

19

Unsolecited DM response,

multiple frame establishedstate TCH Fullrate Inner Area

N WORD 2 1 0

20Sequence error TCH FullrateInner Area

N WORD 2 1 0

21 T_MSRFPCI expired TCHFullrate Inner Area

N WORD 2 1 0

22Distance Limit Exceeded TCH

Fullrate Inner AreaN WORD 2 1 0

23Handover Access Failure TCH

Fullrate Inner AreaN WORD 2 1 0

24Radio Link Failure TCH

Fullrate Inner AreaN WORD 2 1 0

25Remote Transcoder Failure

TCH Fullrate Inner AreaN WORD 2 1 0

26All other causes TCH Fullrate

Inner AreaN WORD 2 1 0

27T200 Expired TCH Halfrate

Inner AreaN WORD 2 1 0

28

Unsolecited DM response,

multiple frame established

state TCH Halfrate Inner Area

N WORD 2 1 0

29Sequence error TCH HalfrateInner Area

N WORD 2 1 0

30 T_MSRFPCI expired TCHHalfrate Inner Area

N WORD 2 1 0

31Distance Limit Exceeded TCHHalfrate Inner Area

N WORD 2 1 0

32Handover Access Failure TCH

Halfrate Inner AreaN WORD 2 1 0

33Radio Link Failure TCH

Halfrate Inner AreaN WORD 2 1 0

34 Remote Transcoder Failure N WORD 2 1 0

Page 26: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 26/222

TCH Halfrate Inner Area

35All other causes TCH Halfrate

Inner Area

N WORD 2 1 0

36T200 Expired TCH FullrateComplete Area

N WORD 2 1 0

37

Unsolecited DM response,

multiple frame established

state TCH Fullrate Complete

Area

N WORD 2 1 0

38Sequence error TCH Fullrate

Complete AreaN WORD 2 1 0

39T_MSRFPCI expired TCH

Fullrate Complete AreaN WORD 2 1 0

40Distance Limit Exceeded TCH

Fullrate Complete AreaN WORD 2 1 0

41Handover Access Failure TCH

Fullrate Complete AreaN WORD 2 1 0

42Radio Link Failure TCHFullrate Complete Area

N WORD 2 1 0

43Remote Transcoder FailureTCH Fullrate Complete Area

N WORD 2 1 0

44 All other causes TCH FullrateComplete Area N WORD 2 1 0

45T200 Expired TCH Halfrate

Complete AreaN WORD 2 1 0

46

Unsolecited DM response,multiple frame established

state TCH Halfrate Complete

Area

N WORD 2 1 0

47Sequence error TCH Halfrate

Complete AreaN WORD 2 1 0

48 T_MSRFPCI expired TCHHalfrate Complete Area

N WORD 2 1 0

49Distance Limit Exceeded TCH

Halfrate Complete AreaN WORD 2 1 0

50Handover Access Failure TCHHalfrate Complete Area

N WORD 2 1 0

51Radio Link Failure TCH

Halfrate Complete AreaN WORD 2 1 0

52 Remote Transcoder Failure N WORD 2 1 0

Page 27: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 27/222

TCH Halfrate Complete Area

53All other causes TCH Halfrate

Complete Area

N WORD 2 1 0

Meas

Name:

(1,2)-- nRFLTCH-- Number

of lost Radio links while

using a TCH (Fullrate,

Halfrate)

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

54T200 Expired TCH Fullrate

Single TimeslotN WORD 2 1 0

55

Unsolecited DM response,multiple frame established

state TCH Fullrate Single

Timeslot

N WORD 2 1 0

56Sequence error TCH FullrateSingle Timeslot

N WORD 2 1 0

57T_MSRFPCI expired TCH

Fullrate Single TimeslotN WORD 2 1 0

58Distance Limit Exceeded TCHFullrate Single Timeslot

N WORD 2 1 0

59Handover Access Failure TCH

Fullrate Single TimeslotN WORD 2 1 0

60Radio Link Failure TCH

Fullrate Single TimeslotN WORD 2 1 0

61Remote Transcoder Failure

TCH Fullrate Single TimeslotN WORD 2 1 0

62All other causes TCH Fullrate

Single TimeslotN WORD 2 1 0

63T200 Expired TCH Halfrate

Single Timeslot

N WORD 2 1 0

64

Unsolecited DM response,

multiple frame established

state TCH Halfrate Single

Timeslot

N WORD 2 1 0

65Sequence error TCH HalfrateSingle Timeslot

N WORD 2 1 0

66T_MSRFPCI expired TCH

Halfrate Single TimeslotN WORD 2 1 0

Page 28: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 28/222

67Distance Limit Exceeded TCHHalfrate Single Timeslot

N WORD 2 1 0

68 Handover Access Failure TCHHalfrate Single Timeslot

N WORD 2 1 0

69Radio Link Failure TCH

Halfrate Single TimeslotN WORD 2 1 0

70Remote Transcoder Failure

TCH Halfrate Single TimeslotN WORD 2 1 0

71All other causes TCH Halfrate

Single TimeslotN WORD 2 1 0

72T200 Expired TCH FullrateDouble Timeslot

N WORD 2 1 0

73

Unsolecited DM response,

multiple frame established

state TCH Fullrate Double

Timeslot

N WORD 2 1 0

74Sequence error TCH FullrateDouble Timeslot

N WORD 2 1 0

75T_MSRFPCI expired TCH

Fullrate Double TimeslotN WORD 2 1 0

76Distance Limit Exceeded TCH

Fullrate Double TimeslotN WORD 2 1 0

77Handover Access Failure TCH

Fullrate Double TimeslotN WORD 2 1 0

78Radio Link Failure TCH

Fullrate Double TimeslotN WORD 2 1 0

79Remote Transcoder Failure

TCH Fullrate Double TimeslotN WORD 2 1 0

80All other causes TCH Fullrate

Double TimeslotN WORD 2 1 0

81T200 Expired TCH Halfrate

Double TimeslotN WORD 2 1 0

82

Unsolecited DM response,

multiple frame established

state TCH Halfrate Double

Timeslot

N WORD 2 1 0

83Sequence error TCH Halfrate

Double TimeslotN WORD 2 1 0

84T_MSRFPCI expired TCH

Halfrate Double TimeslotN WORD 2 1 0

Page 29: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 29/222

85Distance Limit Exceeded TCHHalfrate Double Timeslot

N WORD 2 1 0

86 Handover Access Failure TCHHalfrate Double Timeslot

N WORD 2 1 0

87Radio Link Failure TCH

Halfrate Double TimeslotN WORD 2 1 0

88

Remote Transcoder Failure

TCH Halfrate Double

Timeslot

N WORD 2 1 0

89All other causes TCH Halfrate

Double TimeslotN WORD 2 1 0

Meas

Name:

(1,3)-- nRFLSDCC--Number of lost Radio links

while using a SDCCH

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 T200 Expired N WORD 2 1 0

1 Unsolicited DM Response N WORD 2 1 0

2 Sequence Error N WORD 2 1 0

3 T_MSRFPCI Expired N WORD 2 1 0

4 Distance Limit Exceeded N WORD 2 1 0

5 Handover Access Failure N WORD 2 1 0

6 Radio Link Failure N WORD 2 1 0

7 Remote Transcoder Failure N WORD 2 1 0

8 All Other Causes N WORD 2 1 0

Meas

Name:

(1,4)-- sINTHITA--

Successful Internal

Handovers Intracell per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 DownLink Quality N WORD 2 1 0

2Inner to Complete Area(concentric cell)

N WORD 2 1 0

3Complete to Inner Area

(concentric cell)N WORD 2 1 0

Page 30: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 30/222

4Near to Far Area (extendedcell)

N WORD 2 1 0

5 Far to Near Area (extendedcell)

N WORD 2 1 0

6 Forced Handover due to O_M N WORD 2 1 0

7 TCH/H to TCH/F due to AMR N WORD 2 1 0

8 TCH/F to TCH/H due to AMR N WORD 2 1 0

9Forced Handover due to

enhanced pairing of TCH/HN WORD 2 1 0

10Forced Handover due topreferred TRX

N WORD 2 1 0

11 Forced Handover due toMultislot Calls N WORD 2 1 0

12Compression HO fromFR/EFR to HR

N WORD 2 1 0

13Decompression HO from HR

to FR/EFRN WORD 2 1 0

Meas

Name:

(1,5)-- tACCBPRO-- Total

number of accesses by

procedures

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0 Paging procedure PCH N LONG 4 1 0

1 Access grant procedure AGCH N LONG 4 1 0

Meas

Name:

(1,6)-- nACSUCPR-- Number

of accesses with a successful

result by procedure

Meas Set: 0

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy0 Paging procedure PCH N LONG 4 1 0

1 Access grant procedure AGCH N LONG 4 1 0

2Random access procedure

RACHN LONG 4 1 0

Meas

Name:

(1,7)-- nATTSDPE-- Number

of attempted SDCCH

seizures in a period

Meas Set: 0

Page 31: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 31/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of attempted SDCCHseizures in a period

N LONG 4 1 0

Meas

Name:

(1,8)-- aTSDCMBS--

Attempted SDCCH seizures

meeting an SDCCH blocked

state

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Attempted SDCCH seizures

meeting an SDCCH blockedstate

N WORD 2 1 0

Meas

Name:

(1,9)-- aTIMASCA--

Attempted immediate

assignment procedures per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Answer to paging (SDCCH) N WORD 2 1 0

1 Emergency call (SDCCH) N WORD 2 1 0

2Call reEstablishment

(SDCCH)N WORD 2 1 0

3 Originating call (SDCCH) N WORD 2 1 0

4 Location updating (SDCCH) N WORD 2 1 0

5

Other procedures (IMSI

detach, SMS, SS Manag.,...)

(SDCCH)

N WORD 2 1 0

6 Answer to paging (TCH/F) N WORD 2 1 0

7 Emergency call (TCH/F) N WORD 2 1 0

8 Call reEstablishment (TCH/F) N WORD 2 1 0

9 Originating call (TCH/F) N WORD 2 1 0

10 Answer to paging (TCH/H) N WORD 2 1 0

11 Emergency call (TCH/H) N WORD 2 1 0

12 Call reEstablishment (TCH/H) N WORD 2 1 0

13 Originating call (TCH/H) N WORD 2 1 0

Page 32: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 32/222

Meas

Name:

(1,10)-- sUIMASCA--

Successful immediate

assignment procedures per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Answer to paging N WORD 2 1 0

1 Emergency call N WORD 2 1 0

2 Call reEstablishment N WORD 2 1 0

3 Originating call N WORD 2 1 0

4 Location updating N WORD 2 1 0

5 Other procedures (IMSIdetach, SMS, SS Manag.,...)

N WORD 2 1 0

Meas

Name:

(1,11)-- mEITCHIB-- Mean

number of idle TCH per

interference band

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Interference band 1 N LONG 4 1000 2

1 Interference band 2 N LONG 4 1000 2

2 Interference band 3 N LONG 4 1000 2

3 Interference band 4 N LONG 4 1000 2

4 Interference band 5 N LONG 4 1000 2

Meas

Name:

(1,12)-- uNINHOIA--

Unsuccessful Internal

Handovers Intracell per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 DownLink Quality N WORD 2 1 0

2Inner to Complete Area(concentric cell)

N WORD 2 1 0

3Complete to Inner Area

(concentric cell)N WORD 2 1 0

4Near to Far Area (extended

cell)N WORD 2 1 0

Page 33: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 33/222

5Far to Near Area (extendedcell)

N WORD 2 1 0

6 Forced Handover due to O_M N WORD 2 1 07 TCH/H to TCH/F due to AMR N WORD 2 1 0

8 TCH/F to TCH/H due to AMR N WORD 2 1 0

9Forced Handover due to

enhanced pairing of TCH/HN WORD 2 1 0

10Forced Handover due to

preferred TRXN WORD 2 1 0

11Forced Handover due toMultislot Calls

N WORD 2 1 0

12 Compression HO fromFR/EFR to HR N WORD 2 1 0

13Decompression HO from HRto FR/EFR

N WORD 2 1 0

Meas

Name:

(1,13)-- aTINHIAC--

Attempted Internal

Handovers Intracell per

cause

Meas Set: 0

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy0 Uplink Quality N WORD 2 1 0

1 DownLink Quality N WORD 2 1 0

2Inner to Complete Area(concentric cell)

N WORD 2 1 0

3Complete to Inner Area

(concentric cell)N WORD 2 1 0

4Near to Far Area (extended

cell)N WORD 2 1 0

5 Far to Near Area (extendedcell) N WORD 2 1 0

6 Forced Handover due to O_M N WORD 2 1 0

7 TCH/H to TCH/F due to AMR N WORD 2 1 0

8 TCH/F to TCH/H due to AMR N WORD 2 1 0

9Forced Handover due to

enhanced pairing of TCH/HN WORD 2 1 0

10Forced Handover due topreferred TRX

N WORD 2 1 0

Page 34: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 34/222

11Forced Handover due toMultislot Calls

N WORD 2 1 0

12 Compression HO fromFR/EFR to HR

N WORD 2 1 0

13Decompression HO from HR

to FR/EFRN WORD 2 1 0

Meas

Name:

(1,14)-- aTINHIRC--

Attempted Internal

Handovers Intercell per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

9 Fast Uplink N WORD 2 1 0

10Forced Handover due to

PreemptionN WORD 2 1 0

Meas

Name:

(1,14)-- aTINHIRC--

Attempted Internal

Handovers Intercell per

cause

Meas Set: 1

CounterId

Name Unit Type Size ScaleDigitAccuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

Page 35: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 35/222

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

9 Fast Uplink N WORD 2 1 0

10Forced Handover due to

PreemptionN WORD 2 1 0

11 Forced HO due to DTM N WORD 2 1 0

Meas

Name:

(1,15)-- nAVSDCCH--

Number of Available

SDCCHs

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0 Minimum value N WORD 2 1 0

1 Maximum value N WORD 2 1 0

2 Mean value N LONG 4 1000 2

Meas

Name:

(1,16)-- nAVTCH-- Number

of Available TCHsMeas Set: 0

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy0 Minimun value TCH Fullrate N WORD 2 1 0

1 Maximum value TCH Fullrate N WORD 2 1 0

2 Mean value TCH Fullrate N LONG 4 1000 2

3 Minimun value TCH Halfrate N WORD 2 1 0

4 Maximum value TCH Halfrate N WORD 2 1 0

5 Mean value TCH Halfrate N LONG 4 1000 2

Meas

Name:

(1,16)-- nAVTCH-- Number

of Available TCHs Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

6Minimun value TCH Fullrate

Inner AreaN WORD 2 1 0

7Maximum value TCH Fullrate

Inner AreaN WORD 2 1 0

8Mean value TCH Fullrate

Inner AreaN LONG 4 1000 2

Page 36: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 36/222

9Minimun value TCH HalfrateInner Area

N WORD 2 1 0

10 Maximum value TCH HalfrateInner Area

N WORD 2 1 0

11Mean value TCH Halfrate

Inner AreaN LONG 4 1000 2

12Minimun value TCH Fullrate

Complete AreaN WORD 2 1 0

13Maximum value TCH Fullrate

Complete AreaN WORD 2 1 0

14Mean value TCH FullrateComplete Area

N LONG 4 1000 2

15Minimun value TCH Halfrate

Complete AreaN WORD 2 1 0

16Maximum value TCH Halfrate

Complete AreaN WORD 2 1 0

17Mean value TCH Halfrate

Complete AreaN LONG 4 1000 2

Meas

Name:

(1,16)-- nAVTCH-- Number

of Available TCHsMeas Set: 2

CounterId

Name Unit Type Size Scale DigitAccuracy

18Minimun value TCH Fullrate

Single TimeslotN WORD 2 1 0

19Maximum value TCH Fullrate

Single TimeslotN WORD 2 1 0

20Mean value TCH Fullrate

Single TimeslotN LONG 4 1000 2

21Minimun value TCH Halfrate

Single TimeslotN WORD 2 1 0

22Maximum value TCH Halfrate

Single TimeslotN WORD 2 1 0

23Mean value TCH Halfrate

Single TimeslotN LONG 4 1000 2

24Minimun value TCH Fullrate

Double TimeslotN WORD 2 1 0

25Maximum value TCH FullrateDouble Timeslot

N WORD 2 1 0

26 Mean value TCH Fullrate N LONG 4 1000 2

Page 37: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 37/222

Double Timeslot

27Minimun value TCH Halfrate

Double Timeslot

N WORD 2 1 0

28Maximum value TCH HalfrateDouble Timeslot

N WORD 2 1 0

29Mean value TCH Halfrate

Double TimeslotN LONG 4 1000 2

Meas

Name:

(1,17)-- tNTCHCL-- Total

number of TCH Connections

per cell (Fullrate, Halfrate)

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,17)-- tNTCHCL-- Total

number of TCH Connections

per cell (Fullrate, Halfrate)

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

2 TCH Fullrate Inner Area N WORD 2 1 0

3 TCH Halfrate Inner Area N WORD 2 1 0

4 TCH Fullrate Complete Area N WORD 2 1 0

5 TCH Halfrate Complete Area N WORD 2 1 0

Meas

Name:

(1,17)-- tNTCHCL-- Total

number of TCH Connections

per cell (Fullrate, Halfrate)

Meas Set: 2

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy6 TCH Fullrate Single Timeslot N WORD 2 1 0

7 TCH Halfrate Single Timeslot N WORD 2 1 0

8 TCH Fullrate Double Timeslot N WORD 2 1 0

9TCH Halfrate Double

TimeslotN WORD 2 1 0

Meas

Name:

(1,18)-- uNIHIALC--

Unsuccessful InternalMeas Set: 0

Page 38: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 38/222

Handovers Intracell with

Loss of Connection

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Unsuccessful Internal

Handovers Intracell with Loss

of Connection

N WORD 2 1 0

Meas

Name:

(1,19)-- uNIHIRLC--

Unsuccessful Internal

Handovers Intercell with

Loss of Connection

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Unsuccessful Internal

Handovers Intercell with Lossof Connection

N WORD 2 1 0

Meas

Name:

(1,20)-- aSDCALTI-- All

available SDCCHs allocated

time

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0All available SDCCHs

allocated timesec WORD 2 10 1

1Minimum interval all available

SDCCHs allocatedsec WORD 2 10 1

2Maximum interval all

available SDCCHs allocatedsec WORD 2 10 1

Meas

Name:

(1,21)-- mBUSYSDC-- Mean

number of busy SDCCH percell Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Mean number of busy SDCCH

per cellN LONG 4 1000 2

Meas

Name:

(1,22)-- mAXBUSDC--

Maximum number of busy

SDCCH per cell

Meas Set: 0

Page 39: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 39/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Maximum number of busySDCCH per cell

N WORD 2 1 0

Meas

Name:

(1,23)-- tASSATT-- Total

number of assignment

attempts per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 SDCCH N WORD 2 1 0

1 TCH Fullrate N WORD 2 1 0

2 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,24)-- tASSSUCC-- Total

number of successful

assignments per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 SDCCH N WORD 2 1 0

1 TCH Fullrate N WORD 2 1 0

2 TCH Halfrate N WORD 2 1 0

3 TCH Fullrate directed retry N WORD 2 1 0

4 TCH Halfrate directed retry N WORD 2 1 0

Meas

Name:

(1,25)-- aTTCHSEI--

Attempted TCH Seizures

(Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,26)-- sUCTCHSE--

Successful TCH Seizures

(Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

Page 40: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 40/222

1 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,27)-- aTCHSMBS--Attempted TCH Seizures

meeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,27)-- aTCHSMBS--

Attempted TCH Seizures

meeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

2 TCH Fullrate Inner N WORD 2 1 0

3 TCH Halfrate Inner N WORD 2 1 0

4 TCH Fullrate Complete N WORD 2 1 0

5 TCH Halfrate Complete N WORD 2 1 0

Meas

Name:

(1,27)-- aTCHSMBS--

Attempted TCH Seizures

meeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

6 TCH Fullrate Single Timeslot N WORD 2 1 0

7 TCH Halfrate Single Timeslot N WORD 2 1 0

8 TCH Fullrate Double Timeslot N WORD 2 1 0

9TCH Halfrate Double

TimeslotN WORD 2 1 0

Meas

Name:

(1,27)-- aTCHSMBS--

Attempted TCH Seizures

meeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 3

Counter Name Unit Type Size Scale Digit

Page 41: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 41/222

Id Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

10 TCH Fullrate Abis subchannel N WORD 2 1 0

11 TCH Halfrate Abis subchannel N WORD 2 1 0

Meas

Name:

(1,27)-- aTCHSMBS--

Attempted TCH Seizures

meeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 4

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy2 TCH Fullrate Inner N WORD 2 1 0

3 TCH Halfrate Inner N WORD 2 1 0

4 TCH Fullrate Complete N WORD 2 1 0

5 TCH Halfrate Complete N WORD 2 1 0

10 TCH Fullrate Abis subchannel N WORD 2 1 0

11 TCH Halfrate Abis subchannel N WORD 2 1 0

MeasName:

(1,27)-- aTCHSMBS--

Attempted TCH Seizuresmeeting an TCH blocked

state (Fullrate, Halfrate)

Meas Set: 5

Counter

IdName Unit Type Size Scale

Digit

Accuracy

6 TCH Fullrate Single Timeslot N WORD 2 1 0

7 TCH Halfrate Single Timeslot N WORD 2 1 0

8 TCH Fullrate Double Timeslot N WORD 2 1 0

9TCH Halfrate Double

Timeslot

N WORD 2 1 0

10 TCH Fullrate Abis subchannel N WORD 2 1 0

11 TCH Halfrate Abis subchannel N WORD 2 1 0

Meas

Name:

(1,28)-- mTCHBUTI-- Mean

TCH Busy Time (Fullrate,

Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 42: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 42/222

0 TCH FullRate sec WORD 2 10 1

1 TCH HalfRate sec WORD 2 10 1

Meas

Name:

(1,29)-- sINTHINT--

Successful Internal

Handovers Intercell per

cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 03 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

9 Fast Uplink N WORD 2 1 0

10

Forced Handover due to

Preemption N WORD 2 1 0

Meas

Name:

(1,29)-- sINTHINT--

Successful Internal

Handovers Intercell per

cause

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 02 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

Page 43: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 43/222

9 Fast Uplink N WORD 2 1 0

10Forced Handover due to

Preemption

N WORD 2 1 0

11

Meas

Name:

(1,30)-- tASSFAIL-- Total

number of assignment

failures per cell per cause

per channel type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Radio interface message

failure (SDCCH) N WORD 2 1 0

1

Radio interface message

failure reversion to the old

channel (SDCCH)

N WORD 2 1 0

2Radio resource unavailable

(SDCCH)N WORD 2 1 0

3 Directed retry (SDCCH) N WORD 2 1 0

4 All other causes (SDCCH) N WORD 2 1 0

5Radio interface message

failure (TCH Fullrate)

N WORD 2 1 0

6

Radio interface message

failure reversion to the old

channel (TCH Fullrate)

N WORD 2 1 0

7Radio resource unavailable

(TCH Fullrate)N WORD 2 1 0

8 Directed retry (TCH Fullrate) N WORD 2 1 0

9All other causes (TCH

Fullrate)N WORD 2 1 0

10Radio interface messagefailure (TCH Halfrate) N WORD 2 1 0

11

Radio interface message

failure reversion to the old

channel (TCH Halfrate)

N WORD 2 1 0

12Radio resource Unavailable

(TCH Halfrate)N WORD 2 1 0

13 Directed retry (TCH Halfrate) N WORD 2 1 0

14All other causes (TCH

Halfrate)N WORD 2 1 0

Page 44: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 44/222

 

MeasName:

(1,31)-- nSUCCHPC--

Successful Immediate

Assignment of signalling

channel per cause per

channel type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Answer to paging (SDCCH) N WORD 2 1 0

1 Emergency call (SDCCH) N WORD 2 1 0

2Call reEstablishment(SDCCH)

N WORD 2 1 0

3 Originating call (SDCCH) N WORD 2 1 0

4 Location updating (SDCCH) N WORD 2 1 0

5

Other procedures (IMSI

detach, SMS, SS Manag.,...)

(SDCCH)

N WORD 2 1 0

6 Sms Moc (SDCCH) N WORD 2 1 0

7 Sms Mtc (SDCCH) N WORD 2 1 0

8 Answer to paging (TCH/F) N WORD 2 1 0

9 Emergency call (TCH/F) N WORD 2 1 0

10 Call reEstablishment (TCH/F) N WORD 2 1 0

11 Originating call (TCH/F) N WORD 2 1 0

12 Location updating (TCH/F) N WORD 2 1 0

13

Other procedures (IMSI

detach, SMS, SS Manag.,...)(TCH/F)

N WORD 2 1 0

14 Sms Moc (TCH/F) N WORD 2 1 0

15 Sms Mtc (TCH/F) N WORD 2 1 0

16 Answer to paging (TCH/H) N WORD 2 1 0

17 Emergency call (TCH/H) N WORD 2 1 0

18 Call reEstablishment (TCH/H) N WORD 2 1 0

19 Originating call (TCH/H) N WORD 2 1 0

20 Location updating (TCH/H) N WORD 2 1 0

21

Other procedures (IMSI

detach, SMS, SS Manag.,...)

(TCH/H)

N WORD 2 1 0

22 Sms Moc (TCH/H) N WORD 2 1 0

Page 45: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 45/222

23 Sms Mtc (TCH/H) N WORD 2 1 0

Meas

Name:

(1,32)-- tNMSCNCL-- Totalnumber of multislot

(HSCSD) connections per

cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of HSCSD

connections using 1 TCH/FN WORD 2 1 0

1Number of HSCSD

connections using 2 TCH/FN WORD 2 1 0

2Number of HSCSDconnections using 3 TCH/F

N WORD 2 1 0

3Number of HSCSD

connections using 4 TCH/FN WORD 2 1 0

Meas

Name:

(1,33)-- mTCHQLEN-- Mean

TCH queue length (Fullrate,

Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Fullrate TCH request N LONG 4 1000 2

1 Halfrate TCH request N LONG 4 1000 2

Meas

Name:

(1,34)-- mDURTCRQ-- Mean

duration a TCH request is

queued (Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Assignment request for Fullrate

TCH sec LONG 4 1000 2

1Assignment request for

Halfrate TCHsec LONG 4 1000 2

2Handover request for Fullrate

TCHsec LONG 4 1000 2

3Handover request for Halfrate

TCHsec LONG 4 1000 2

Meas (1,35)-- nMSGDISQ-- Meas Set: 0

Page 46: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 46/222

Name: Number of messages

discarded from the TCH

queue per cell (Fullrate,

Halfrate)

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Assignment request forFullrate TCH

N WORD 2 1 0

1Assignment request forHalfrate TCH

N WORD 2 1 0

2Handover request for FullrateTCH

N WORD 2 1 0

3 Handover request for HalfrateTCH

N WORD 2 1 0

Meas

Name:

(1,36)-- nASUSDPE--

Number of successful

SDCCH seizures in a period

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of successful SDCCH

seizures in a periodN WORD 2 1 0

Meas

Name:

(1,37)-- tNSUDHSC--

Number of service

upgrades/downgrades for

HSCSD calls

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Upgrades due to quality or

levelN WORD 2 1 0

1 Downgrades due to quality orlevel N WORD 2 1 0

2Downgrades due to lack of resources

N WORD 2 1 0

3Upgrades due to subscriber

requestN WORD 2 1 0

4Downgrades due to subscriber

requestN WORD 2 1 0

5 Upgrades due to Intracell or N WORD 2 1 0

Page 47: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 47/222

Intercell Intra BSC Handoverexecution

6Downgrades due to Intracell orIntercell Intra BSC Handover

execution

N WORD 2 1 0

7

Downgrades due to lack of 

resources for multislot

connections

N WORD 2 1 0

Meas

Name:

(1,38)-- tASSATVS-- Total

number of Assignment

Attempts relevant to

VBS/VGCSBroadcast/Group Channels

per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

MeasName:

(1,39)-- tASSUCVS-- Total

number of Successful

Assignment relevant toVBS/VGCS

Broadcast/Group Channels

per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH Fullrate N WORD 2 1 0

1 TCH Halfrate N WORD 2 1 0

Meas

Name:

(1,40)-- nNNOTNCH--

Number of new Notifications

to be sent on the Notification

Channel (NCH)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of new Notificationsto be sent on the Notification

Channel (NCH)

N WORD 2 1 0

Page 48: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 48/222

Meas

Name:

(1,41)-- nRDEFTCH--

Number of defined TCHs

(Fullrate, Halfrate)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Minimun value TCH Fullrate N WORD 2 1 0

1 Maximum value TCH Fullrate N WORD 2 1 0

2 Mean value TCH Fullrate N LONG 4 1000 2

3 Minimun value TCH Halfrate N WORD 2 1 0

4 Maximum value TCH Halfrate N WORD 2 1 0

5 Mean value TCH Halfrate N LONG 4 1000 2

Meas

Name:

(1,41)-- nRDEFTCH--

Number of defined TCHs

(Fullrate, Halfrate)

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

6Minimun value TCH Fullrate

Inner AreaN WORD 2 1 0

7Maximum value TCH Fullrate

Inner AreaN WORD 2 1 0

8Mean value TCH Fullrate

Inner AreaN LONG 4 1000 2

9Minimun value TCH Halfrate

Inner AreaN WORD 2 1 0

10Maximum value TCH HalfrateInner Area

N WORD 2 1 0

11Mean value TCH Halfrate

Inner AreaN LONG 4 1000 2

12Minimun value TCH Fullrate

Complete Area

N WORD 2 1 0

13Maximum value TCH Fullrate

Complete AreaN WORD 2 1 0

14Mean value TCH Fullrate

Complete AreaN LONG 4 1000 2

15Minimun value TCH Halfrate

Complete AreaN WORD 2 1 0

16Maximum value TCH Halfrate

Complete AreaN WORD 2 1 0

Page 49: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 49/222

17Mean value TCH HalfrateComplete Area

N LONG 4 1000 2

Meas

Name:

(1,41)-- nRDEFTCH--

Number of defined TCHs

(Fullrate, Halfrate)

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

18Minimun value TCH Fullrate

Single TimeslotN WORD 2 1 0

19Maximum value TCH Fullrate

Single TimeslotN WORD 2 1 0

20Mean value TCH FullrateSingle Timeslot

N LONG 4 1000 2

21Minimun value TCH Halfrate

Single TimeslotN WORD 2 1 0

22Maximum value TCH Halfrate

Single TimeslotN WORD 2 1 0

23Mean value TCH Halfrate

Single TimeslotN LONG 4 1000 2

24Minimun value TCH Fullrate

Double TimeslotN WORD 2 1 0

25Maximum value TCH Fullrate

Double TimeslotN WORD 2 1 0

26Mean value TCH Fullrate

Double TimeslotN LONG 4 1000 2

27Minimun value TCH Halfrate

Double TimeslotN WORD 2 1 0

28Maximum value TCH Halfrate

Double TimeslotN WORD 2 1 0

29

Mean value TCH Halfrate

Double Timeslot N LONG 4 1000 2

Meas

Name:

(1,42)-- nDESDCCH--

Number of Defined SDCCHsMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Minimum number of definedSDCCHs

N WORD 2 1 0

1 Maximum number of defined N WORD 2 1 0

Page 50: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 50/222

SDCCHs

2Mean number of defined

SDCCHs

N LONG 4 1000 2

Meas

Name:

(1,43)-- nHOINRHA--

Number of Handover

indications not resulting in a

Handover attempt

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Empty Preferred List N WORD 2 1 0

1 No MSC Command N WORD 2 1 0

2 No Suitable Cell N WORD 2 1 0

3 No Suitable Channel N WORD 2 1 0

Meas

Name:

(1,44)-- nAVTCHSD--

Number of Available

TCH/SD

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Minimum value N WORD 2 1 0

1 Maximum value N WORD 2 1 0

2 Mean value N LONG 4 1000 2

Meas

Name:

(1,45)-- nTCHSDCM--

Number of TCH-SDCCH

channel modifications

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of TCH-SDCCH

channel modifications TCH toSDCCH

N WORD 2 1 0

1

Number of TCH-SDCCH

channel modifications SDCCH

to TCH

N WORD 2 1 0

Meas

Name:

(1,46)-- nDFTCHSD--

Number of Defined TCH/SDMeas Set: 0

Counter Name Unit Type Size Scale Digit

Page 51: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 51/222

Id Accuracy

0 Number of Defined TCH/SD N WORD 2 1 0

Meas

Name:

(1,47)-- aISHINTR--

Attempted Internal SDCCH

Handovers Intracell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Attempted Internal SDCCH

Handovers IntracellN WORD 2 1 0

MeasName:

(1,48)-- sISHINTR--

Successful Internal SDCCH

Handovers Intracell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Successful Internal SDCCH

Handovers IntracellN WORD 2 1 0

Meas

Name:

(1,49)-- uISHINTR--

Unsuccessful Internal

SDCCH Handovers Intracell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Unsuccessful Internal SDCCH

Handovers IntracellN WORD 2 1 0

Meas

Name:

(1,50)-- aISHINTE--

Attempted Internal SDCCH

Handovers Intercell

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0Attempted Internal SDCCH

Handovers IntercellN WORD 2 1 0

Meas

Name:

(1,51)-- sISHINTE--

Successful Internal SDCCH

Handovers Intercell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 52: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 52/222

0Successful Internal SDCCHHandovers Intercell

N WORD 2 1 0

Meas

Name:

(1,52)-- uISHINTE--

Unsuccessful Internal

SDCCH Handovers Intercell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Unsuccessful Internal SDCCH

Handovers IntercellN WORD 2 1 0

MeasName:

(1,53)-- aOINTESH--

Attempted MSC ControlledSDCCH Handovers

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Attempted MSC Controlled

SDCCH HandoversN WORD 2 1 0

Meas

Name:

(1,54)-- sOINTESH--

Successful MSC Controlled

SDCCH Handovers

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Successful MSC Controlled

SDCCH HandoversN WORD 2 1 0

Meas

Name:

(1,55)-- uOINTESH--

Unsuccessful MSC

Controlled SDCCH

Handovers

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0Unsuccessful MSC Controlled

SDCCH HandoversN WORD 2 1 0

Meas

Name:

(1,56)-- mBTCHCHT-- Mean

number of busy TCH per

channel type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 53: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 53/222

0 TCH/FS N LONG 4 1000 2

1 TCH/EFS N LONG 4 1000 2

2 TCH/AFS N LONG 4 1000 2

3 TCH/FD N LONG 4 1000 2

4 TCH/HS N LONG 4 1000 2

5 TCH/AHS N LONG 4 1000 2

Meas

Name:

(1,57)-- mDURTCSD-- Mean

Duration a TCH/SD

(TCH/SD_Pool) can be used

as SDCCH

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Mean Duration a TCH/SD

(TCH/SD_Pool) can be used as

SDCCH

sec LONG 4 1000 2

Meas

Name:

(1,58)-- nRCLRREQ--

Number of Clear Request

messages per cell per cause

per channel type

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0 Equipment failure (TCH/F) N WORD 2 1 0

1Radio interface failure

(TCH/F)N WORD 2 1 0

2Radio interface message

failure (TCH/F)N WORD 2 1 0

3Radio resource not available(TCH/F)

N WORD 2 1 0

4 Protocol error (TCH/F) N WORD 2 1 05 Distance (TCH/F) N WORD 2 1 0

6 Preemption (TCH/F) N WORD 2 1 0

7 O_M Intervention (TCH/F) N WORD 2 1 0

8 Others (TCH/F) N WORD 2 1 0

9 Equipment failure (TCH/H) N WORD 2 1 0

10Radio interface failure(TCH/H)

N WORD 2 1 0

11 Radio interface message N WORD 2 1 0

Page 54: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 54/222

failure (TCH/H)

12Radio resource not available

(TCH/H)

N WORD 2 1 0

13 Protocol error (TCH/H) N WORD 2 1 0

14 Distance (TCH/H) N WORD 2 1 0

15 Preemption (TCH/H) N WORD 2 1 0

16 O_M Intervention (TCH/H) N WORD 2 1 0

17 Others (TCH/H) N WORD 2 1 0

18 Equipment failure (SDCCH) N WORD 2 1 0

19Radio interface failure

(SDCCH)N WORD 2 1 0

20Radio interface messagefailure (SDCCH)

N WORD 2 1 0

21Radio resource not available

(SDCCH)N WORD 2 1 0

22 Protocol error (SDCCH) N WORD 2 1 0

23 Distance (SDCCH) N WORD 2 1 0

24 O_M Intervention (SDCCH) N WORD 2 1 0

25 Others (SDCCH) N WORD 2 1 0

Meas

Name:

(1,59)-- nRCLRCMD--

Number of Clear Command

messages per cell per cause

per channel type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 BSS initiated (TCH/F) N WORD 2 1 0

1 Call control (TCH/F) N WORD 2 1 0

2 Handover successful (TCH/F) N WORD 2 1 0

3 Equipment failure (TCH/F) N WORD 2 1 0

4 Protocol error (TCH/F) N WORD 2 1 0

5 Others (TCH/F) N WORD 2 1 0

6 BSS initiated (TCH/H) N WORD 2 1 0

7 Call control (TCH/H) N WORD 2 1 0

8 Handover successful (TCH/H) N WORD 2 1 0

9 Equipment failure (TCH/H) N WORD 2 1 0

10 Protocol error (TCH/H) N WORD 2 1 0

Page 55: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 55/222

11 Others (TCH/H) N WORD 2 1 0

12 BSS initiated (SDCCH) N WORD 2 1 0

13 Call control (SDCCH) N WORD 2 1 0

14Handover successful

(SDCCH)N WORD 2 1 0

15 Equipment failure (SDCCH) N WORD 2 1 0

16 Protocol error (SDCCH) N WORD 2 1 0

17 Others (SDCCH) N WORD 2 1 0

Meas

Name:

(1,60)-- aCADMCDMA--

Number of calls admitted on

the DMA layer

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of admitted CS

speech calls in the layerassociated to the CFHSY0

hopping law

N WORD 2 1 0

1

Number of admitted CS

speech calls in the layer

associated to the CFHSY1

hopping law

N WORD 2 1 0

Meas

Name:

(1,60)-- aCADMCDMA--

Number of calls admitted on

the DMA layer

Meas Set: 255

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Meas

Name:

(1,61)-- aCREJCDMA--

Number of calls rejected on

the DMA layer

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of rejected CS speech

calls on the DMA layer due to

enableSoftBlocking==TRUE

in the layer associated to the

CFHSY0 hopping law

N WORD 2 1 0

1 Number of rejected CS speech N WORD 2 1 0

Page 56: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 56/222

calls on the DMA layer due toenableSoftBlocking==TRUE

in the layer associated to the

CFHSY1 hopping law

Meas

Name:

(1,61)-- aCREJCDMA--

Number of calls rejected on the

DMA layer

Meas Set: 255

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Meas

Name:

(1,62)-- uISHIALC--

Unsuccessful InternalSDCCH Handovers Intracell

with loss of connection per

cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Unsuccessful Internal SDCCH

Handovers Intracell with loss

of connection per cell

N WORD 2 1 0

Meas

Name:

(1,63)-- uISHIRLC--Unsuccessful Internal

SDCCH Handovers Intercell

with loss of connection per

cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Unsuccessful Internal SDCCH

Handovers Intercell with loss

of connection per cell

N WORD 2 1 0

Meas

Name:

(1,64)-- uMCSHLC--

Unsuccessful MSC

controlled SDCCH

Handovers with loss of 

connection per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Unsuccessful MSC controlledSDCCH Handovers with loss

N WORD 2 1 0

Page 57: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 57/222

of connection per cell

Meas

Name:

(1,65)-- cHALNHLY--Number of channel

allocation requests not

served in the highest layer or

not served at all per service

type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Signalling (SDCCH), not in

the highest LYN WORD 2 1 0

1 CS speech, not in the highestLY

N WORD 2 1 0

2CS speech AMR FR, not in the

highest LYN WORD 2 1 0

3CS speech AMR HR, not inthe highest LY

N WORD 2 1 0

4 CS data, not in the highest LY N WORD 2 1 0

5 HSCSD, not in the highest LY N WORD 2 1 0

6 GPRS , not in the highest LY N WORD 2 1 0

7 EGPRS , not in the highest LY N WORD 2 1 08 ASCI, not in the highest LY N WORD 2 1 0

9Signalling (SDCCH), not

served at allN WORD 2 1 0

10 CS speech, not served at all N WORD 2 1 0

11CS speech AMR FR, not

served at allN WORD 2 1 0

12CS speech AMR HR, not

served at allN WORD 2 1 0

13 CS data, not served at all N WORD 2 1 014 HSCSD, not served at all N WORD 2 1 0

15 GPRS, not served at all N WORD 2 1 0

16 EGPRS, not served at all N WORD 2 1 0

17 ASCI, not served at all N WORD 2 1 0

18Total number of requests for

Signalling (SDCCH)N WORD 2 1 0

19Total number of requests for

CS speechN WORD 2 1 0

Page 58: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 58/222

20Total number of requests forCS speech AMR FR

N WORD 2 1 0

21 Total number of requests forCS speech AMR HR

N WORD 2 1 0

22Total number of requests for

CS dataN WORD 2 1 0

23Total number of requests for

HSCSDN WORD 2 1 0

24Total number of requests for

GPRSN WORD 2 1 0

25Total number of requests forEGPRS

N WORD 2 1 0

26Total number of requests for

ASCIN WORD 2 1 0

Meas

Name:

(1,66)-- mEBUTSLY-- Mean

number of busy channels per

layer

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Mean number of busy channels

for FR in LY0N LONG 4 1000 2

1Mean number of busy channels

for HR in LY0N LONG 4 1000 2

2Mean number of busy channels

for PO in LY0N LONG 4 1000 2

3Mean number of busy channels

for FR in LY1N LONG 4 1000 2

4Mean number of busy channels

for HR in LY1N LONG 4 1000 2

5

Mean number of busy channels

for PO in LY1 N LONG 4 1000 2

6Mean number of busy channels

for FR in LY2N LONG 4 1000 2

7Mean number of busy channelsfor HR in LY2

N LONG 4 1000 2

8Mean number of busy channels

for PO in LY2N LONG 4 1000 2

9Mean number of busy channels

for FR in LY3N LONG 4 1000 2

Page 59: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 59/222

10Mean number of busy channelsfor HR in LY3

N LONG 4 1000 2

11 Mean number of busy channelsfor PO in LY3

N LONG 4 1000 2

12Mean number of busy channels

for FR in LY4N LONG 4 1000 2

13Mean number of busy channels

for HR in LY4N LONG 4 1000 2

14Mean number of busy channels

for PO in LY4N LONG 4 1000 2

15Mean number of busy channelsfor FR in LY5

N LONG 4 1000 2

16Mean number of busy channels

for HR in LY5N LONG 4 1000 2

17Mean number of busy channels

for PO in LY5N LONG 4 1000 2

18Mean number of busy channels

for FR in LY6N LONG 4 1000 2

19Mean number of busy channels

for HR in LY6N LONG 4 1000 2

20Mean number of busy channels

for PO in LY6

N LONG 4 1000 2

21Mean number of busy channelsfor FR in LY7

N LONG 4 1000 2

22Mean number of busy channels

for HR in LY7N LONG 4 1000 2

23Mean number of busy channelsfor PO in LY7

N LONG 4 1000 2

24Mean number of busy channels

for FR in LY8N LONG 4 1000 2

25

Mean number of busy channels

for HR in LY8 N LONG 4 1000 2

26Mean number of busy channels

for PO in LY8N LONG 4 1000 2

27Mean number of busy channels

for FR in LY9N LONG 4 1000 2

28Mean number of busy channels

for HR in LY9N LONG 4 1000 2

29Mean number of busy channels

for PO in LY9N LONG 4 1000 2

Page 60: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 60/222

30Mean number of busy channelsfor FR in LY10

N LONG 4 1000 2

31 Mean number of busy channelsfor HR in LY10

N LONG 4 1000 2

32Mean number of busy channels

for PO in LY10N LONG 4 1000 2

33Mean number of busy channels

for FR in LY11N LONG 4 1000 2

34Mean number of busy channels

for HR in LY11N LONG 4 1000 2

35Mean number of busy channelsfor PO in LY11

N LONG 4 1000 2

Meas

Name:

(1,66)-- mEBUTSLY-- Mean

number of busy channels per

layer

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

36Mean number of busy channels

for FR in LY0 in SLPAN LONG 4 1000 2

37Mean number of busy channels

for HR in LY0 in SLPAN LONG 4 1000 2

38Mean number of busy channels

for PO in LY0 in SLPAN LONG 4 1000 2

39Mean number of busy channels

for FR in LY1 in SLPAN LONG 4 1000 2

40Mean number of busy channels

for HR in LY1 in SLPAN LONG 4 1000 2

41Mean number of busy channels

for PO in LY1 in SLPAN LONG 4 1000 2

42

Mean number of busy channels

for FR in LY2 in SLPA N LONG 4 1000 2

43Mean number of busy channels

for HR in LY2 in SLPAN LONG 4 1000 2

44Mean number of busy channelsfor PO in LY2 in SLPA

N LONG 4 1000 2

45Mean number of busy channels

for FR in LY3 in SLPAN LONG 4 1000 2

46Mean number of busy channels

for HR in LY3 in SLPAN LONG 4 1000 2

Page 61: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 61/222

47Mean number of busy channelsfor PO in LY3 in SLPA

N LONG 4 1000 2

48 Mean number of busy channelsfor FR in LY4 in SLPA

N LONG 4 1000 2

49Mean number of busy channels

for HR in LY4 in SLPAN LONG 4 1000 2

50Mean number of busy channels

for PO in LY4 in SLPAN LONG 4 1000 2

51Mean number of busy channels

for FR in LY5 in SLPAN LONG 4 1000 2

52Mean number of busy channelsfor HR in LY5 in SLPA

N LONG 4 1000 2

53Mean number of busy channels

for PO in LY5 in SLPAN LONG 4 1000 2

54Mean number of busy channels

for FR in LY6 in SLPAN LONG 4 1000 2

55Mean number of busy channels

for HR in LY6 in SLPAN LONG 4 1000 2

56Mean number of busy channels

for PO in LY6 in SLPAN LONG 4 1000 2

57Mean number of busy channels

for FR in LY7 in SLPA

N LONG 4 1000 2

58Mean number of busy channelsfor HR in LY7 in SLPA

N LONG 4 1000 2

59Mean number of busy channels

for PO in LY7 in SLPAN LONG 4 1000 2

60Mean number of busy channelsfor FR in LY8 in SLPA

N LONG 4 1000 2

61Mean number of busy channels

for HR in LY8 in SLPAN LONG 4 1000 2

62

Mean number of busy channels

for PO in LY8 in SLPA N LONG 4 1000 2

63Mean number of busy channels

for FR in LY9 in SLPAN LONG 4 1000 2

64Mean number of busy channels

for HR in LY9 in SLPAN LONG 4 1000 2

65Mean number of busy channels

for PO in LY9 in SLPAN LONG 4 1000 2

66Mean number of busy channels

for FR in LY10 in SLPAN LONG 4 1000 2

Page 62: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 62/222

67Mean number of busy channelsfor HR in LY10 in SLPA

N LONG 4 1000 2

68 Mean number of busy channelsfor PO in LY10 in SLPA

N LONG 4 1000 2

69Mean number of busy channels

for FR in LY11 in SLPAN LONG 4 1000 2

70Mean number of busy channels

for HR in LY11 in SLPAN LONG 4 1000 2

71Mean number of busy channels

for PO in LY11 in SLPAN LONG 4 1000 2

72Mean number of busy channelsfor FR in LY0 in SLCA

N LONG 4 1000 2

73Mean number of busy channels

for HR in LY0 in SLCAN LONG 4 1000 2

74Mean number of busy channels

for PO in LY0 in SLCAN LONG 4 1000 2

75Mean number of busy channels

for FR in LY1 in SLCAN LONG 4 1000 2

76Mean number of busy channels

for HR in LY1 in SLCAN LONG 4 1000 2

77Mean number of busy channels

for PO in LY1 in SLCA

N LONG 4 1000 2

78Mean number of busy channelsfor FR in LY2 in SLCA

N LONG 4 1000 2

79Mean number of busy channels

for HR in LY2 in SLCAN LONG 4 1000 2

80Mean number of busy channelsfor PO in LY2 in SLCA

N LONG 4 1000 2

81Mean number of busy channels

for FR in LY3 in SLCAN LONG 4 1000 2

82

Mean number of busy channels

for HR in LY3 in SLCA N LONG 4 1000 2

83Mean number of busy channels

for PO in LY3 in SLCAN LONG 4 1000 2

84Mean number of busy channels

for FR in LY4 in SLCAN LONG 4 1000 2

85Mean number of busy channels

for HR in LY4 in SLCAN LONG 4 1000 2

86Mean number of busy channels

for PO in LY4 in SLCAN LONG 4 1000 2

Page 63: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 63/222

87Mean number of busy channelsfor FR in LY5 in SLCA

N LONG 4 1000 2

88 Mean number of busy channelsfor HR in LY5 in SLCA

N LONG 4 1000 2

89Mean number of busy channels

for PO in LY5 in SLCAN LONG 4 1000 2

90Mean number of busy channels

for FR in LY6 in SLCAN LONG 4 1000 2

91Mean number of busy channels

for HR in LY6 in SLCAN LONG 4 1000 2

92Mean number of busy channelsfor PO in LY6 in SLCA

N LONG 4 1000 2

93Mean number of busy channels

for FR in LY7 in SLCAN LONG 4 1000 2

94Mean number of busy channels

for HR in LY7 in SLCAN LONG 4 1000 2

95Mean number of busy channels

for PO in LY7 in SLCAN LONG 4 1000 2

96Mean number of busy channels

for FR in LY8 in SLCAN LONG 4 1000 2

97Mean number of busy channels

for HR in LY8 in SLCA

N LONG 4 1000 2

98Mean number of busy channelsfor PO in LY8 in SLCA

N LONG 4 1000 2

99Mean number of busy channels

for FR in LY9 in SLCAN LONG 4 1000 2

100Mean number of busy channelsfor HR in LY9 in SLCA

N LONG 4 1000 2

101Mean number of busy channels

for PO in LY9 in SLCAN LONG 4 1000 2

102

Mean number of busy channels

for FR in LY10 in SLCA N LONG 4 1000 2

103Mean number of busy channels

for HR in LY10 in SLCAN LONG 4 1000 2

104Mean number of busy channels

for PO in LY10 in SLCAN LONG 4 1000 2

105Mean number of busy channels

for FR in LY11 in SLCAN LONG 4 1000 2

106Mean number of busy channels

for HR in LY11 in SLCAN LONG 4 1000 2

Page 64: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 64/222

107Mean number of busy channelsfor PO in LY11 in SLCA

N LONG 4 1000 2

Meas

Name:

(1,66)-- mEBUTSLY-- Mean

number of busy channels per

layer

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

108Mean number of busy channels

for FR in LY0 for BCCH bandN LONG 4 1000 2

109Mean number of busy channels

for HR in LY0 for BCCH bandN LONG 4 1000 2

110Mean number of busy channelsfor PO in LY0 for BCCH band

N LONG 4 1000 2

111Mean number of busy channels

for FR in LY1 for BCCH bandN LONG 4 1000 2

112Mean number of busy channels

for HR in LY1 for BCCH bandN LONG 4 1000 2

113Mean number of busy channels

for PO in LY1 for BCCH bandN LONG 4 1000 2

114Mean number of busy channels

for FR in LY2 for BCCH bandN LONG 4 1000 2

115Mean number of busy channels

for HR in LY2 for BCCH bandN LONG 4 1000 2

116Mean number of busy channels

for PO in LY2 for BCCH bandN LONG 4 1000 2

117Mean number of busy channels

for FR in LY3 for BCCH bandN LONG 4 1000 2

118Mean number of busy channels

for HR in LY3 for BCCH bandN LONG 4 1000 2

119

Mean number of busy channels

for PO in LY3 for BCCH band N LONG 4 1000 2

120Mean number of busy channels

for FR in LY4 for BCCH bandN LONG 4 1000 2

121Mean number of busy channelsfor HR in LY4 for BCCH band

N LONG 4 1000 2

122Mean number of busy channels

for PO in LY4 for BCCH bandN LONG 4 1000 2

123Mean number of busy channels

for FR in LY5 for BCCH bandN LONG 4 1000 2

Page 65: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 65/222

124Mean number of busy channelsfor HR in LY5 for BCCH band

N LONG 4 1000 2

125 Mean number of busy channelsfor PO in LY5 for BCCH band

N LONG 4 1000 2

126Mean number of busy channels

for FR in LY6 for BCCH bandN LONG 4 1000 2

127Mean number of busy channels

for HR in LY6 for BCCH bandN LONG 4 1000 2

128Mean number of busy channels

for PO in LY6 for BCCH bandN LONG 4 1000 2

129Mean number of busy channelsfor FR in LY7 for BCCH band

N LONG 4 1000 2

130Mean number of busy channels

for HR in LY7 for BCCH bandN LONG 4 1000 2

131Mean number of busy channels

for PO in LY7 for BCCH bandN LONG 4 1000 2

132Mean number of busy channels

for FR in LY8 for BCCH bandN LONG 4 1000 2

133Mean number of busy channels

for HR in LY8 for BCCH bandN LONG 4 1000 2

134Mean number of busy channels

for PO in LY8 for BCCH band

N LONG 4 1000 2

135Mean number of busy channelsfor FR in LY9 for BCCH band

N LONG 4 1000 2

136Mean number of busy channels

for HR in LY9 for BCCH bandN LONG 4 1000 2

137Mean number of busy channelsfor PO in LY9 for BCCH band

N LONG 4 1000 2

138

Mean number of busy channels

for FR in LY10 for BCCH

band

N LONG 4 1000 2

139Mean number of busy channelsfor HR in LY10 for BCCH

band

N LONG 4 1000 2

140

Mean number of busy channels

for PO in LY10 for BCCHband

N LONG 4 1000 2

141

Mean number of busy channels

for FR in LY11 for BCCH

band

N LONG 4 1000 2

Page 66: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 66/222

142Mean number of busy channelsfor HR in LY11 for BCCH

band

N LONG 4 1000 2

143

Mean number of busy channels

for PO in LY11 for BCCH

band

N LONG 4 1000 2

144

Mean number of busy channels

for FR in LY0 for non-BCCH

band

N LONG 4 1000 2

145Mean number of busy channelsfor HR in LY0 for non-BCCHband

N LONG 4 1000 2

146 Mean number of busy channelsfor PO in LY0 for non-BCCH

band

N LONG 4 1000 2

147

Mean number of busy channels

for FR in LY1 for non-BCCH

band

N LONG 4 1000 2

148Mean number of busy channelsfor HR in LY1 for non-BCCH

band

N LONG 4 1000 2

149

Mean number of busy channels

for PO in LY1 for non-BCCHband N LONG 4 1000 2

150

Mean number of busy channels

for FR in LY2 for non-BCCHband

N LONG 4 1000 2

151Mean number of busy channelsfor HR in LY2 for non-BCCH

band

N LONG 4 1000 2

152

Mean number of busy channels

for PO in LY2 for non-BCCH

band

N LONG 4 1000 2

153

Mean number of busy channels

for FR in LY3 for non-BCCH

band

N LONG 4 1000 2

154Mean number of busy channelsfor HR in LY3 for non-BCCH

band

N LONG 4 1000 2

155

Mean number of busy channels

for PO in LY3 for non-BCCHband

N LONG 4 1000 2

Page 67: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 67/222

156Mean number of busy channelsfor FR in LY4 for non-BCCH

band

N LONG 4 1000 2

157

Mean number of busy channels

for HR in LY4 for non-BCCH

band

N LONG 4 1000 2

158

Mean number of busy channels

for PO in LY4 for non-BCCH

band

N LONG 4 1000 2

159Mean number of busy channelsfor FR in LY5 for non-BCCHband

N LONG 4 1000 2

160 Mean number of busy channelsfor HR in LY5 for non-BCCH

band

N LONG 4 1000 2

161

Mean number of busy channels

for PO in LY5 for non-BCCH

band

N LONG 4 1000 2

162Mean number of busy channelsfor FR in LY6 for non-BCCH

band

N LONG 4 1000 2

163

Mean number of busy channels

for HR in LY6 for non-BCCHband N LONG 4 1000 2

164

Mean number of busy channels

for PO in LY6 for non-BCCHband

N LONG 4 1000 2

165Mean number of busy channelsfor FR in LY7 for non-BCCH

band

N LONG 4 1000 2

166

Mean number of busy channels

for HR in LY7 for non-BCCH

band

N LONG 4 1000 2

167

Mean number of busy channels

for PO in LY7 for non-BCCH

band

N LONG 4 1000 2

168Mean number of busy channelsfor FR in LY8 for non-BCCH

band

N LONG 4 1000 2

169

Mean number of busy channels

for HR in LY8 for non-BCCHband

N LONG 4 1000 2

Page 68: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 68/222

170Mean number of busy channelsfor PO in LY8 for non-BCCH

band

N LONG 4 1000 2

171

Mean number of busy channels

for FR in LY9 for non-BCCH

band

N LONG 4 1000 2

172

Mean number of busy channels

for HR in LY9 for non-BCCH

band

N LONG 4 1000 2

173Mean number of busy channelsfor PO in LY9 for non-BCCHband

N LONG 4 1000 2

174 Mean number of busy channelsfor FR in LY10 for non-BCCH

band

N LONG 4 1000 2

175

Mean number of busy channels

for HR in LY10 for non-BCCH

band

N LONG 4 1000 2

176Mean number of busy channelsfor PO in LY10 for non-BCCH

band

N LONG 4 1000 2

177

Mean number of busy channels

for FR in LY11 for non-BCCHband N LONG 4 1000 2

178

Mean number of busy channels

for HR in LY11 for non-BCCHband

N LONG 4 1000 2

179Mean number of busy channelsfor PO in LY11 for non-BCCH

band

N LONG 4 1000 2

Meas

Name:

(1,67)-- wPSSUPV--

Supervision of WirelessPriority Services

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of TCH Requests for

WPSN WORD 2 1 0

1Number of TCH Requests

forwarded to WPS QueueN WORD 2 1 0

2 - Number of queued TCH N WORD 2 1 0

Page 69: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 69/222

Requests for WPS, discardedfrom the queue due to timers

expiry

3

Number of queued TCH

Requests for WPS, discarded

from the queue due to

preemption, or not entering thequeue

N WORD 2 1 0

4

Number of queued TCH

Requests for WPS, discarded

from the queue due tohandovers

N WORD 2 1 0

5

Number of queued TCH

Requests for WPS, discarded

from the queue due to call

release or MS lost

N WORD 2 1 0

6Number of successful queued

TCH Requests for WPSN WORD 2 1 0

7

Number of assigned Public

Queue requests, when a WPS

call is in queue

N WORD 2 1 0

8

Number of assigned WPS

Queue requests, when a Public

call is in queue

N WORD 2 1 0

9Mean duration a TCH requestis queued for WPS

sec LONG 4 1000 2

10Mean duration a handover

request is queued for WPSsec LONG 4 1000 2

Meas

Name:

(1,68)-- mBUSYSSP-- Mean

number of busy SDCCHs per

signalling procedure

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0Mean number of busy

SDCCHs for Speech signallingN LONG 4 1000 2

1Mean number of busy

SDCCHs for SMS signallingN LONG 4 1000 2

2Mean number of busy

SDCCHs for USSD signallingN LONG 4 1000 2

3 Mean number of busy N LONG 4 1000 2

Page 70: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 70/222

SDCCHs for SS signalling

4Mean number of busy

SDCCHs for other signalling

N LONG 4 1000 2

5Mean number of busySDCCHs for abnormal cases

N LONG 4 1000 2

Meas

Name:

(1,69)-- nSUSDSUS-- Number

of successful SDCCH seizures

for USSD signalling

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of successful SDCCH

seizures for USSD signalling N LONG 4 1 0

Meas

Name:

(1,70)-- nTCHLOEV--

Number of TCH load events

on Um and Abis per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Value of traffic handover

control timer (TRFCT) at endof GP

N LONG 4 1 0

1Number of traffic HO enabling

due to high TCH load at Um-IFN LONG 4 1 0

2

Number of Traffic HO

enabling due to high

SUBTSLB at Abis-IF

N LONG 4 1 0

3

No. times an incoming TCHrequest met with a radio TCH

load higher than non-AMR half 

rate activation threshold for

standard cells, concentric

cells(complete area), extendedcells (far area)

N LONG 4 1 0

4

No. times an incoming TCH

request met with a radio TCHload higher than non-AMR half 

rate activation threshold for

concentric cells (inner area),

extended cells (near area)

N LONG 4 1 0

5No. times an incoming TCH

request met with a radio TCHN LONG 4 1 0

Page 71: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 71/222

load higher than AMR half rateactivation threshold for

standard cells, concentric

cells(complete area), extended

cells (far area)

6

No. times an incoming TCH

request met with a radio TCHload higher than AMR half rate

activation threshold for

concentric cells (inner area),

extended cells (near area)

N LONG 4 1 0

7

No. times an incoming TCHrequest met with an Abis

subchannel (SUBTSLB) loadhigher than the Abis half rate

activation threshold

N LONG 4 1 0

8

Number of non-AMR

compression HO enabling dueto high radio TCH load at Um-

IF for standard cells, concentric

cells (complete area), extended

cells (far area)

N LONG 4 1 0

9

Number of non-AMR

compression HO enabling dueto high radio TCH load at Um-

IF for concentric cells (innerarea), extended cells (near area)

N LONG 4 1 0

10

Number of AMR compression

HO enabling due to high radio

TCH load at Um-IF forstandard cells, concentric cells

(complete area), extended cells

(far area)

N LONG 4 1 0

11

Number of AMR compression

HO enabling due to high radioTCH load at Um-IF forconcentric cells (inner area),

extended cells (near area)

N LONG 4 1 0

12

Number of (non-AMR or

AMR) compression HO

enabling due to highSUBTSLB load at Abis-IF

N LONG 4 1 0

13No. times exceeding the

threshold for enhanced TCH/HN LONG 4 1 0

Page 72: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 72/222

pairing is detected due to highradio TCH load at Um-IF for

standard cells, concentric cells

(complete area), extended cells

(far area)

14

No. times exceeding the

threshold for enhanced TCH/Hpairing is detected due to high

radio TCH load at Um-IF for

concentric cells (inner area),

extended cells (near area)

N LONG 4 1 0

15

No. times exceeding thethreshold for enhanced TCH/H

pairing is detected due to highSUBTSLB load at Abis-IF

N LONG 4 1 0

Meas

Name:

(1,71)-- sUCTCHARP--

Successful TCH Seizures by

ARP capable MS per channel

type

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Successful TCH/F seizures per

ARP capable MS N LONG 4 1 0

1Successful TCH/H seizures per

ARP capable MSN LONG 4 1 0

Meas

Name:

(1,72)-- nASSARP-- Number

of Successful Assignments

Related to MS with ARP

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of successfulassignments according to MS

with ARP capability

N LONG 4 1 0

Meas

Name:

(1,73)-- nFLTCHARP--

Number of Lost Radio Links

while using a TCH related to

MS with ARP

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 73: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 73/222

0Number of lost radio links toMS with ARP capability

N LONG 4 1 0

scannerObjectClass: /BSS/SCANBTSE (2)

Meas

Name:

(2,0)-- nINVRACH-- Number

of Invalid RACH Messages

per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Signal Level Too Weak N LONG 4 1 0

1 Excessive Distance N LONG 4 1 0

2 Other Causes N LONG 4 1 0

Meas

Name:

(2,1)-- nTDMPCH-- Number

of Transmitted and

Discarded Messages on the

PCH per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Transmittedmessages on the PCH for CS

traffic

N WORD 2 1 0

1

Number of Transmitted

messages on the PCH for PS

traffic

N WORD 2 1 0

2Number of messagesDiscarded from the paging

queue for CS traffic

N WORD 2 1 0

3

Number of messages

Discarded from the pagingqueue for PS traffic

N WORD 2 1 0

Meas

Name:

(2,1)-- nTDMPCH-- Number

of Transmitted and

Discarded Messages on the

PCH per cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 74: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 74/222

4Number of Transmittedmessages (per subscriber) on

the PCH for CS traffic

N LONG 4 1 0

5

Number of Transmitted

messages (per subscriber) on

the PCH for PS traffic

N LONG 4 1 0

6

Number of messages (per

subscriber) Discarded from the

paging queue for CS traffic

N LONG 4 1 0

7Number of messages (persubscriber) Discarded from thepaging queue for PS traffic

N LONG 4 1 0

8 Number of Transmitted utilizedPCH frames on the air interface N LONG 4 1 0

9

Number of Extended Paging

mode starts due to overload in

original paging queue

N LONG 4 1 0

10

Number of PagingReorganization mode starts dueto overload in original paging

queue

N LONG 4 1 0

Meas

Name:

(2,2)-- aMRCHDIS--Adaptive Multirate channel

type Uplink/Downlink

distribution

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TCH/AFS 2.2 Uplink % WORD 2 100 2

1 TCH/AFS 10.2 Uplink % WORD 2 100 2

2 TCH/AFS 7.95 Uplink % WORD 2 100 2

3 TCH/AFS 7.4 Uplink % WORD 2 100 2

4 TCH/AFS 6.7 Uplink % WORD 2 100 2

5 TCH/AFS 5.9 Uplink % WORD 2 100 2

6 TCH/AFS 5.15 Uplink % WORD 2 100 2

7 TCH/AFS 4.75 Uplink % WORD 2 100 2

8 TCH/AHS 7.4 Uplink % WORD 2 100 2

9 TCH/AHS 6.7 Uplink % WORD 2 100 2

10 TCH/AHS 5.9 Uplink % WORD 2 100 2

Page 75: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 75/222

11 TCH/AHS 5.15 Uplink % WORD 2 100 2

12 TCH/AHS 4.75 Uplink % WORD 2 100 2

13 TCH/AFS 12.2 Downlink % WORD 2 100 2

14 TCH/AFS 10.2 Downlink % WORD 2 100 2

15 TCH/AFS 7.95 Downlink % WORD 2 100 2

16 TCH/AFS 7.4 Downlink % WORD 2 100 2

17 TCH/AFS 6.7 Downlink % WORD 2 100 2

18 TCH/AFS 5.9 Downlink % WORD 2 100 2

19 TCH/AFS 5.15 Downlink % WORD 2 100 2

20 TCH/AFS 4.75 Downlink % WORD 2 100 2

21 TCH/AHS 7.4 Downlink % WORD 2 100 222 TCH/AHS 6.7 Downlink % WORD 2 100 2

23 TCH/AHS 5.9 Downlink % WORD 2 100 2

24 TCH/AHS 5.15 Downlink % WORD 2 100 2

25 TCH/AHS 4.75 Downlink % WORD 2 100 2

Meas

Name:

(2,3)-- aMRVAR-- Voice

Activity Rate for Adaptive

Multi-Rate (AMR) on

Uplink/Downlink busy TCHs

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 AMRVAR Uplink % WORD 2 100 2

1 AMRVAR Downlink % WORD 2 100 2

Meas

Name:

(2,4)-- aMRFRMUL-- Frame

measurements for Adaptive

Multi-Rate (AMR) on uplink

busy TCHs

Meas Set: 0

CounterId

Name Unit Type Size ScaleDigitAccuracy

0

TCH/AFS 12.2 Uplink Correct

Frames (AMR full rate speech,

12.2 kbps)

N LONG 4 1 0

1

TCH/AFS 10.2 Uplink Correct

Frames (AMR full rate speech,10.2 kbps)

N LONG 4 1 0

2 TCH/AFS 7.95 Uplink Correct N LONG 4 1 0

Page 76: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 76/222

Frames (AMR full rate speech,7.95 kbps)

3TCH/AFS 7.4 Uplink CorrectFrames (AMR full rate speech,

7.4 kbps)

N LONG 4 1 0

4

TCH/AFS 6.7 Uplink Correct

Frames (AMR full rate speech,

6.7 kbps)

N LONG 4 1 0

5

TCH/AFS 5.9 Uplink Correct

Frames (AMR full rate speech,5.9 kbps)

N LONG 4 1 0

6

TCH/AFS 5.15 Uplink Correct

Frames (AMR full rate speech,5.15 kbps) N LONG 4 1 0

7

TCH/AFS 4.75 Uplink Correct

Frames (AMR full rate speech,

4.75 kbps)

N LONG 4 1 0

8

TCH/AHS 7.4 Uplink CorrectFrames (AMR half rate speech,7.4 kbps)

N LONG 4 1 0

9

TCH/AHS 6.7 Uplink Correct

Frames (AMR half rate speech,

6.7 kbps)

N LONG 4 1 0

10

TCH/AHS 5.9 Uplink Correct

Frames (AMR half rate speech,

5.9 kbps)

N LONG 4 1 0

11

TCH/AHS 5.15 Uplink Correct

Frames (AMR half rate speech,5.15 kbps)

N LONG 4 1 0

12

TCH/AHS 4.75 Uplink Correct

Frames (AMR half rate speech,

4.75 kbps)

N LONG 4 1 0

13TCH/AFS 12.2 Uplink ErrorFrames (AMR full rate speech,

12.2 kbps)

N LONG 4 1 0

14

TCH/AFS 10.2 Uplink Error

Frames (AMR full rate speech,10.2 kbps)

N LONG 4 1 0

15

TCH/AFS 7.95 Uplink Error

Frames (AMR full rate speech,

7.95 kbps)

N LONG 4 1 0

16 TCH/AFS 7.4 Uplink Error N LONG 4 1 0

Page 77: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 77/222

Frames (AMR full rate speech,7.4 kbps)

17TCH/AFS 6.7 Uplink ErrorFrames (AMR full rate speech,

6.7 kbps)

N LONG 4 1 0

18

TCH/AFS 5.9 Uplink Error

Frames (AMR full rate speech,

5.9 kbps)

N LONG 4 1 0

19

TCH/AFS 5.15 Uplink Error

Frames (AMR full rate speech,5.15 kbps)

N LONG 4 1 0

20

TCH/AFS 4.75 Uplink Error

Frames (AMR full rate speech,4.75 kbps) N LONG 4 1 0

21

TCH/AHS 7.4 Uplink Error

Frames (AMR half rate speech,

7.4 kbps)

N LONG 4 1 0

22

TCH/AHS 6.7 Uplink ErrorFrames (AMR half rate speech,6.7 kbps)

N LONG 4 1 0

23

TCH/AHS 5.9 Uplink Error

Frames (AMR half rate speech,

5.9 kbps)

N LONG 4 1 0

24

TCH/AHS 5.15 Uplink Error

Frames (AMR half rate speech,

5.15 kbps)

N LONG 4 1 0

25

TCH/AHS 4.75 Uplink Error

Frames (AMR half rate speech,4.75 kbps)

N LONG 4 1 0

Meas

Name:

(2,5)-- aMRFRMDL-- Frame

measurements for Adaptive

Multi-Rate (AMR) onDownlink busy TCHs

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0AMR Downlink Correct

FramesN LONG 4 1 0

1 AMR Downlink Error Frames N LONG 4 1 0

Meas (2,6)-- aMRSIDUL-- Meas Set: 0

Page 78: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 78/222

Name: SID_UPDATE frame

measurements for Adaptive

Multi-Rate (AMR) on Uplink

busy TCHs

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0AMR Uplink Correct SIDFrames

N LONG 4 1 0

1 AMR Uplink Error SID Frames N LONG 4 1 0

Meas

Name:

(2,7)-- nINVPRACH--

Number of Invalid PRACH

messages per cell per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Signal Level Too Weak N WORD 2 1 0

1 Excessive Distance N WORD 2 1 0

2 Other Causes N WORD 2 1 0

Meas

Name:

(2,8)-- nTDMAGCH--

Number of Transmitted and

Discarded messages on theAGCH per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of transmitted

messages on the AGCH for CS

traffic

N WORD 2 1 0

1Number of transmittedmessages on the AGCH for PS

traffic

N WORD 2 1 0

2 Number of messages discardedfrom AGCH for CS traffic

N WORD 2 1 0

3Number of messages discardedfrom AGCH for PS traffic

N WORD 2 1 0

Meas

Name:

(2,8)-- nTDMAGCH--

Number of Transmitted and

Discarded messages on the

AGCH per cell

Meas Set: 1

Page 79: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 79/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

4Number of transmittedmessages on the AGCH for CS

traffic

N LONG 4 1 0

5

Number of transmitted

messages on the AGCH for PS

traffic

N LONG 4 1 0

6Number of messages discarded

from AGCH for CS trafficN LONG 4 1 0

7Number of messages discardedfrom AGCH for PS traffic

N LONG 4 1 0

Meas

Name:

(2,9)-- nDEFCCCH--

Number of all Defined CCCH

channels

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink N LONG 4 1 0

1 Downlink N LONG 4 1 0

MeasName:

(2,10)-- nCRLBRQU--Normal call release of calls

with bad radio quality

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of normal call releases

originated by the MS of nonAMR calls with bad radio

quality

N LONG 4 1 0

1

Number of normal call releases

originated by the MS of AMRcalls with bad radio quality N LONG 4 1 0

2

Number of normal call releases

originated by the network of 

non AMR calls with bad radioquality

N LONG 4 1 0

3

Number of normal call releasesoriginated by the network of 

AMR calls with bad radio

quality

N LONG 4 1 0

Page 80: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 80/222

 

MeasName:

(2,11)-- nFRMULARP--

Frame Measurements for

AMR only for MS with ARP

capability on Uplink Busy

TCHs

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of correct framesreceived from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 12.2 Kbit/s

N LONG 4 1 0

1

Number of correct frames

received from MS with ARPcapability on TCH/AFS (AMR

fullrate speech) - 10.2 Kbit/s

N LONG 4 1 0

2

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AMRfullrate speech) - 7.95 Kbit/s

N LONG 4 1 0

3

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 7.4 Kbit/s

N LONG 4 1 0

4

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 6.7 Kbit/s

N LONG 4 1 0

5

Number of correct framesreceived from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 5.9 Kbit/s

N LONG 4 1 0

6

Number of correct frames

received from MS with ARPcapability on TCH/AFS (AMR

fullrate speech) - 5.15 Kbit/s

N LONG 4 1 0

7

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AMRfullrate speech) - 4.75 Kbit/s

N LONG 4 1 0

8

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AHR

N LONG 4 1 0

Page 81: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 81/222

halfrate speech) - 7.4 Kbit/s

9

Number of correct frames

received from MS with ARPcapability on TCH/AFS (AHR

halfrate speech) - 6.7 Kbit/s

N LONG 4 1 0

10

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AHR

halfrate speech) - 5.9 Kbit/s

N LONG 4 1 0

11

Number of correct framesreceived from MS with ARPcapability on TCH/AFS (AHR

halfrate speech) - 5.15 Kbit/s

N LONG 4 1 0

12

Number of correct frames

received from MS with ARP

capability on TCH/AFS (AHRhalfrate speech) - 4.75 Kbit/s

N LONG 4 1 0

13

Number of error frames

received from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 12.2 Kbit/s

N LONG 4 1 0

14

Number of error frames

received from MS with ARP

capability on TCH/AFS (AMRfullrate speech) - 10.2 Kbit/s

N LONG 4 1 0

15

Number of error framesreceived from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 7.95 Kbit/s

N LONG 4 1 0

16

Number of error frames

received from MS with ARPcapability on TCH/AFS (AMR

fullrate speech) - 7.4 Kbit/s

N LONG 4 1 0

17

Number of error framesreceived from MS with ARP

capability on TCH/AFS (AMRfullrate speech) - 6.7 Kbit/s

N LONG 4 1 0

18

Number of error frames

received from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 5.9 Kbit/s

N LONG 4 1 0

19Number of error frames

received from MS with ARPN LONG 4 1 0

Page 82: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 82/222

capability on TCH/AFS (AMRfullrate speech) - 5.15 Kbit/s

20Number of error framesreceived from MS with ARP

capability on TCH/AFS (AMR

fullrate speech) - 4.75 Kbit/s

N LONG 4 1 0

21

Number of error frames

received from MS with ARP

capability on TCH/AFS (AHR

halfrate speech) - 7.4 Kbit/s

N LONG 4 1 0

22

Number of error framesreceived from MS with ARP

capability on TCH/AFS (AHR

halfrate speech) - 6.7 Kbit/s

N LONG 4 1 0

23

Number of error frames

received from MS with ARPcapability on TCH/AFS (AHR

halfrate speech) - 5.9 Kbit/s

N LONG 4 1 0

24

Number of error frames

received from MS with ARP

capability on TCH/AFS (AHRhalfrate speech) - 5.15 Kbit/s

N LONG 4 1 0

25

Number of error frames

received from MS with ARPcapability on TCH/AFS (AHR

halfrate speech) - 4.75 Kbit/s

N LONG 4 1 0

Meas

Name:

(2,12)-- nFRMDLARP--

Frame Measurements for

AMR only for MS with ARP

capability on Downlink Busy

TCHs

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0Number of correct framesreceived by MS with ARP

capability

N LONG 4 1 0

1

Number of erroneous or

missing DL speech frames

received by MS with ARP

capability

N LONG 4 1 0

Page 83: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 83/222

Meas

Name:

(2,13)-- mBTSPWR-- BTS

Power Measurements on

Downlink Busy TCHs

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Mean BTS Power dBm LONG 4 1 0

1Mean BTS Power only for MS

with ARP capabilitydBm LONG 4 1 0

Meas

Name:

(2,14)-- rXQUARP--

Measurements Related to MS

with ARP on Downlink Busy

TCHs

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

RXQUAL level less than or

equal to 5 for MS with ARP

capability

dBm LONG 4 1 0

1RXQUAL level 6 for MS withARP capability

dBm LONG 4 1 0

2RXQUAL level 7 for MS with

ARP capabilitydBm LONG 4 1 0

Meas

Name:

(2,15)-- fACCHSUP--

FACCH SupervisionMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of I(ASSHOCMD),

UI(PHYS_INFO) and UA

frames transmitted over Abis -

TCH/AFS

N LONG 4 1 0

1Number of I(ASSHOCMD),UI(PHYS_INFO) and UA

frames transmitted over Abis -TCH/AHS

N LONG 4 1 0

2

Number of I(ASSHOCMD),UI(PHYS_INFO) and UA

frames transmitted over Abis -

TCH/EFS

N LONG 4 1 0

3Number of I(ASSHOCMD),

UI(PHYS_INFO) and UAN LONG 4 1 0

Page 84: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 84/222

frames transmitted over Abis -TCH/FS

4Number of I(ASSHOCMD),UI(PHYS_INFO) and UA

frames transmitted over Abis -

TCH/HS

N LONG 4 1 0

5

Number of I(ASSHOCMD),

UI(PHYS_INFO) and UA

frames transmitted over Um -

TCH/AFS

N LONG 4 1 0

6

Number of I(ASSHOCMD),UI(PHYS_INFO) and UA

frames transmitted over Um -

TCH/AHS

N LONG 4 1 0

7

Number of I(ASSHOCMD),

UI(PHYS_INFO) and UAframes transmitted over Um -

TCH/EFS

N LONG 4 1 0

8

Number of I(ASSHOCMD),

UI(PHYS_INFO) and UA

frames transmitted over Um -TCH/FS

N LONG 4 1 0

9

Number of I(ASSHOCMD),

UI(PHYS_INFO) and UAframes transmitted over Um -

TCH/HS

N LONG 4 1 0

scannerObjectClass: /BSS/SCANBTSIHO (3)

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

Page 85: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 85/222

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4 Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

Page 86: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 86/222

8Traffic (Complete toComplete)

N WORD 2 1 0

9 Fast Uplink (Complete toComplete)

N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)

N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21Forced Handover due toPreemption (Complete toInner)

N WORD 2 1 0

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers perOriginating Cell

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2 Uplink Strength (Complete to N WORD 2 1 0

Page 87: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 87/222

Complete)

3Downlink Strength (Complete

to Complete)

N WORD 2 1 0

4Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete) N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)

N WORD 2 1 0

24Uplink Strength (Inner toComplete)

N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner toComplete)

N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

Page 88: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 88/222

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 3

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3 Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12 Downlink Quality (Completeto Inner)

N WORD 2 1 0

13Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete toInner)

N WORD 2 1 0

Page 89: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 89/222

17Directed Retry (Complete toInner)

N WORD 2 1 0

18 Forced Handover due to O_M(Complete to Inner)

N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

22Uplink Quality (Inner toComplete)

N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28 Directed Retry (Inner toComplete)

N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner toComplete)

N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner toInner)

N WORD 2 1 0

35Uplink Strength (Inner to

Inner)N WORD 2 1 0

36Downlink Strength (Inner to

Inner)N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

Page 90: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 90/222

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40 Forced Handover due to O_M(Inner to Inner)

N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43Forced Handover due to

Preemption (Inner to Inner)N WORD 2 1 0

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers perOriginating Cell

Meas Set: 4

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3 Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced Handover due to DTM

(Complete to Complete)N WORD 2 1 0

Page 91: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 91/222

 

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 5

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete) N WORD 2 1 0

8Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced Handover due to DTM

(Complete to Complete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Completeto Inner)

N WORD 2 1 0

Page 92: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 92/222

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)

N WORD 2 1 0

17Directed Retry (Complete toInner)

N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21Forced Handover due toPreemption (Complete to

Inner)

N WORD 2 1 0

45Forced Handover due to DTM

(Complete to Inner)N WORD 2 1 0

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 6

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4

Distance (Complete to

Complete) N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete toComplete)

N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

Page 93: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 93/222

9Fast Uplink (Complete toComplete)

N WORD 2 1 0

10Forced Handover due toPreemption (Complete to

Complete)

N WORD 2 1 0

44Forced Handover due to DTM

(Complete to Complete)N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)

N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32Forced Handover due toPreemption (Inner toComplete)

N WORD 2 1 0

46Forced Handover due to DTM

(Inner to Complete)N WORD 2 1 0

Meas

Name:

(3,0)-- sININIRH--

Successful Incoming Internal

Intercell Handovers per

Originating Cell

Meas Set: 7

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1 Downlink Quality (Complete N WORD 2 1 0

Page 94: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 94/222

to Complete)

2Uplink Strength (Complete to

Complete)

N WORD 2 1 0

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete) N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced Handover due to DTM

(Complete to Complete)

N WORD 2 1 0

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

Page 95: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 95/222

21Forced Handover due toPreemption (Complete to

Inner)

N WORD 2 1 0

45Forced Handover due to DTM

(Complete to Inner)N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31 Fast Uplink (Inner toComplete)

N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

46Forced Handover due to DTM(Inner to Complete)

N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner toInner)

N WORD 2 1 0

35Uplink Strength (Inner to

Inner)N WORD 2 1 0

36Downlink Strength (Inner to

Inner)N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40 Forced Handover due to O_M N WORD 2 1 0

Page 96: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 96/222

(Inner to Inner)

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43Forced Handover due to

Preemption (Inner to Inner)N WORD 2 1 0

47Forced Handover due to DTM

(Inner to Inner)N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--

Attempted Incoming

Internal Intercell Handovers

per Originating Cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete toComplete) N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--

Attempted IncomingMeas Set: 1

Page 97: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 97/222

Internal Intercell Handovers

per Originating Cell

CounterId

Name Unit Type Size Scale DigitAccuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10Forced Handover due toPreemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13 Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete toInner)

N WORD 2 1 0

Page 98: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 98/222

18Forced Handover due to O_M(Complete to Inner)

N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete toInner)

N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--

Attempted Incoming

Internal Intercell Handovers

per Originating Cell

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete) N WORD 2 1 0

4Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete toComplete)

N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8 Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

Page 99: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 99/222

23Downlink Quality (Inner toComplete)

N WORD 2 1 0

24 Uplink Strength (Inner toComplete)

N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete) N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

MeasName:

(3,1)-- aININIRH--

Attempted IncomingInternal Intercell Handovers

per Originating Cell

Meas Set: 3

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2

Uplink Strength (Complete to

Complete) N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

Page 100: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 100/222

7Forced Handover due to O_M(Complete to Complete)

N WORD 2 1 0

8 Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)

N WORD 2 1 0

18Forced Handover due to O_M(Complete to Inner)

N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete toInner)

N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

22

Uplink Quality (Inner to

Complete) N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27 Better Cell (Inner to N WORD 2 1 0

Page 101: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 101/222

Complete)

28Directed Retry (Inner to

Complete)

N WORD 2 1 0

29Forced Handover due to O_M(Inner to Complete)

N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner toComplete)

N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner to

Inner)N WORD 2 1 0

35Uplink Strength (Inner to

Inner)N WORD 2 1 0

36Downlink Strength (Inner to

Inner)N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43Forced Handover due toPreemption (Inner to Inner)

N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--

Attempted Incoming

Internal Intercell Handoversper Originating Cell

Meas Set: 4

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2 Uplink Strength (Complete to N WORD 2 1 0

Page 102: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 102/222

Complete)

3Downlink Strength (Complete

to Complete)

N WORD 2 1 0

4Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete) N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--Attempted Incoming

Internal Intercell Handovers

per Originating Cell

Meas Set: 5

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2 Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6 Directed Retry (Complete to N WORD 2 1 0

Page 103: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 103/222

Complete)

7Forced Handover due to O_M

(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM(Complete to Complete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16 Better Cell (Complete toInner)

N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M(Complete to Inner)

N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

45Forced HO due to DTM

(Complete to Inner)N WORD 2 1 0

Meas

Name:

(3,1)-- aININIRH--

Attempted Incoming

Internal Intercell Handovers

per Originating Cell

Meas Set: 6

Page 104: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 104/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete toComplete)

N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)

N WORD 2 1 0

10Forced Handover due toPreemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM(Complete to Complete)

N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24 Uplink Strength (Inner toComplete)

N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

Page 105: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 105/222

29Forced Handover due to O_M(Inner to Complete)

N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner toComplete)

N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

MeasName:

(3,1)-- aININIRH--

Attempted IncomingInternal Intercell Handovers

per Originating Cell

Meas Set: 7

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete) N WORD 2 1 0

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete toComplete)

N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7 Forced Handover due to O_M(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

Page 106: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 106/222

44Forced HO due to DTM(Complete to Complete)

N WORD 2 1 0

11 Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner) N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete toInner)

N WORD 2 1 0

45Forced HO due to DTM

(Complete to Inner)N WORD 2 1 0

22Uplink Quality (Inner toComplete)

N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner toComplete)

N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

Page 107: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 107/222

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)

N WORD 2 1 0

32Forced Handover due toPreemption (Inner to

Complete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner to

Inner)N WORD 2 1 0

35Uplink Strength (Inner to

Inner) N WORD 2 1 0

36Downlink Strength (Inner to

Inner)N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43Forced Handover due to

Preemption (Inner to Inner)N WORD 2 1 0

47Forced HO due to DTM (Inner

to Inner)N WORD 2 1 0

scannerObjectClass: /BSS/SCANBTSM (4)

Meas

Name:

(4,0)-- bTSEPRLD--Measurement of BTSE

Processor Load

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Measurement of BTSE

Processor Load% WORD 2 100 2

Meas (4,1)-- iFRMABIS-- I-Frame Meas Set: 0

Page 108: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 108/222

Name: Measurement on Abis

Interface on BTSE side

CounterId

Name Unit Type Size Scale DigitAccuracy

0Number of Transmitted I-

Frames (from BTSE side)N LONG 4 1 0

2Number of Received I-Frames

(on BTSE side)N LONG 4 1 0

3Number of Badly Received I-Frames (on BTSE side)

N LONG 4 1 0

MeasName:

(4,1)-- iFRMABIS-- I-Frame

Measurement on Abis

Interface on BTSE side

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Transmitted I-

Frames (from BTSE side)N LONG 4 1 0

1

Number of discarded I-Frames

from the transmit queue on

BTSE side

N LONG 4 1 0

2 Number of Received I-Frames(on BTSE side) N LONG 4 1 0

3Number of Badly Received I-

Frames (on BTSE side)N LONG 4 1 0

scannerObjectClass: /BSS/SCANBTSOHOI (5)

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers percause per neighbour cell

relationship

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

Page 109: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 109/222

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3 Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete toComplete)

N WORD 2 1 0

MeasName:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2 Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6 Directed Retry (Complete to N WORD 2 1 0

Page 110: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 110/222

Complete)

7Forced Handover due to O_M

(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17 Directed Retry (Complete toInner)

N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete toInner)

N WORD 2 1 0

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality (Complete to N WORD 2 1 0

Page 111: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 111/222

Page 112: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 112/222

32Forced Handover due toPreemption (Inner to

Complete)

N WORD 2 1 0

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 3

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5

Better Cell (Complete to

Complete) N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10Forced Handover due toPreemption (Complete toComplete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Completeto Inner)

N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

Page 113: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 113/222

14Downlink Strength (Completeto Inner)

N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete toInner)

N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete toInner)

N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25 Downlink Strength (Inner toComplete)

N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner to

Inner)N WORD 2 1 0

Page 114: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 114/222

35Uplink Strength (Inner toInner)

N WORD 2 1 0

36 Downlink Strength (Inner toInner)

N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43 Forced Handover due toPreemption (Inner to Inner)

N WORD 2 1 0

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 4

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

Page 115: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 115/222

9Fast Uplink (Complete toComplete)

N WORD 2 1 0

10Forced Handover due toPreemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 5

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3

Downlink Strength (Complete

to Complete) N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8 Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete toComplete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

Page 116: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 116/222

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12 Downlink Quality (Completeto Inner)

N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner) N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

Meas

Name:

(5,0)-- sOUINIRH--

Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Meas Set: 6

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Uplink Quality (Complete to

Complete) N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

Page 117: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 117/222

5Better Cell (Complete toComplete)

N WORD 2 1 0

6 Directed Retry (Complete toComplete)

N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10Forced Handover due toPreemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner toComplete)

N WORD 2 1 0

24Uplink Strength (Inner toComplete)

N WORD 2 1 0

25 Downlink Strength (Inner toComplete) N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner toComplete)

N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

Meas (5,0)-- sOUINIRH-- Meas Set: 7

Page 118: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 118/222

Name: Successful Outgoing Internal

Intercell Handovers per

cause per neighbour cell

relationship

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3 Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM(Complete to Complete)

N WORD 2 1 0

11 Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Completeto Inner)

N WORD 2 1 0

13Uplink Strength (Complete to

Inner)N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

Page 119: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 119/222

16Better Cell (Complete toInner)

N WORD 2 1 0

17 Directed Retry (Complete toInner)

N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete toInner)

N WORD 2 1 0

45Forced HO due to DTM

(Complete to Inner)N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)

N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner toComplete)

N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete) N WORD 2 1 0

32Forced Handover due toPreemption (Inner to

Complete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner to

Inner)N WORD 2 1 0

Page 120: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 120/222

35Uplink Strength (Inner toInner)

N WORD 2 1 0

36 Downlink Strength (Inner toInner)

N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43 Forced Handover due toPreemption (Inner to Inner)

N WORD 2 1 0

47Forced HO due to DTM (Inner

to Inner)N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

Page 121: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 121/222

8Traffic (Complete toComplete)

N WORD 2 1 0

9 Fast Uplink (Complete toComplete)

N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3

Downlink Strength (Complete

to Complete) N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8 Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete toComplete)

N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

Page 122: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 122/222

12Downlink Quality (Completeto Inner)

N WORD 2 1 0

13 Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner) N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted OutgoingInternal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete toComplete)

N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2 Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6 Directed Retry (Complete to N WORD 2 1 0

Page 123: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 123/222

Complete)

7Forced Handover due to O_M

(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete toComplete)

N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

22Uplink Quality (Inner toComplete)

N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28 Directed Retry (Inner toComplete)

N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner toComplete)

N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 3

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality (Complete to N WORD 2 1 0

Page 124: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 124/222

Complete)

1Downlink Quality (Complete

to Complete)

N WORD 2 1 0

2Uplink Strength (Complete toComplete)

N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete) N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

Page 125: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 125/222

21Forced Handover due toPreemption (Complete to

Inner)

N WORD 2 1 0

22Uplink Quality (Inner to

Complete)N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete)N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32Forced Handover due toPreemption (Inner toComplete)

N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner toInner)

N WORD 2 1 0

35Uplink Strength (Inner to

Inner)N WORD 2 1 0

36Downlink Strength (Inner toInner)

N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43 Forced Handover due to N WORD 2 1 0

Page 126: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 126/222

Preemption (Inner to Inner)

Meas

Name:

(5,1)-- aOUINIRH--Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 4

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete)N WORD 2 1 0

6Directed Retry (Complete to

Complete) N WORD 2 1 0

7Forced Handover due to O_M(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete toComplete)

N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 5

Counter Name Unit Type Size Scale Digit

Page 127: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 127/222

Id Accuracy

0Uplink Quality (Complete to

Complete)

N WORD 2 1 0

1Downlink Quality (Completeto Complete)

N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3Downlink Strength (Complete

to Complete)N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete to

Complete) N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10Forced Handover due toPreemption (Complete toComplete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

11Uplink Quality (Complete toInner)

N WORD 2 1 0

12Downlink Quality (Complete

to Inner)N WORD 2 1 0

13

Uplink Strength (Complete to

Inner) N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete to

Inner)N WORD 2 1 0

18 Forced Handover due to O_M N WORD 2 1 0

Page 128: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 128/222

(Complete to Inner)

19 Traffic (Complete to Inner) N WORD 2 1 0

20 Fast Uplink (Complete toInner)

N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

45Forced HO due to DTM

(Complete to Inner)N WORD 2 1 0

MeasName:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handoversper cause per neighbour cell

relationship

Meas Set: 6

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete) N WORD 2 1 0

3Downlink Strength (Completeto Complete)

N WORD 2 1 0

4Distance (Complete to

Complete)N WORD 2 1 0

5Better Cell (Complete toComplete)

N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7 Forced Handover due to O_M(Complete to Complete)

N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete)N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

Page 129: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 129/222

44Forced HO due to DTM(Complete to Complete)

N WORD 2 1 0

22 Uplink Quality (Inner toComplete)

N WORD 2 1 0

23Downlink Quality (Inner to

Complete)N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner to

Complete) N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner to

Complete)N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner toComplete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

Meas

Name:

(5,1)-- aOUINIRH--

Attempted Outgoing

Internal Intercell Handovers

per cause per neighbour cell

relationship

Meas Set: 7

CounterId

Name Unit Type Size Scale DigitAccuracy

0Uplink Quality (Complete to

Complete)N WORD 2 1 0

1Downlink Quality (Complete

to Complete)N WORD 2 1 0

2Uplink Strength (Complete to

Complete)N WORD 2 1 0

3 Downlink Strength (Complete N WORD 2 1 0

Page 130: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 130/222

to Complete)

4Distance (Complete to

Complete)

N WORD 2 1 0

5Better Cell (Complete toComplete)

N WORD 2 1 0

6Directed Retry (Complete to

Complete)N WORD 2 1 0

7Forced Handover due to O_M

(Complete to Complete)N WORD 2 1 0

8Traffic (Complete to

Complete)N WORD 2 1 0

9Fast Uplink (Complete to

Complete) N WORD 2 1 0

10

Forced Handover due to

Preemption (Complete to

Complete)

N WORD 2 1 0

44Forced HO due to DTM

(Complete to Complete)N WORD 2 1 0

11Uplink Quality (Complete to

Inner)N WORD 2 1 0

12Downlink Quality (Complete

to Inner)

N WORD 2 1 0

13Uplink Strength (Complete toInner)

N WORD 2 1 0

14Downlink Strength (Complete

to Inner)N WORD 2 1 0

15 Distance (Complete to Inner) N WORD 2 1 0

16Better Cell (Complete to

Inner)N WORD 2 1 0

17Directed Retry (Complete toInner)

N WORD 2 1 0

18Forced Handover due to O_M

(Complete to Inner)N WORD 2 1 0

19 Traffic (Complete to Inner) N WORD 2 1 0

20Fast Uplink (Complete to

Inner)N WORD 2 1 0

21

Forced Handover due to

Preemption (Complete to

Inner)

N WORD 2 1 0

45 Forced HO due to DTM N WORD 2 1 0

Page 131: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 131/222

(Complete to Inner)

22Uplink Quality (Inner to

Complete)

N WORD 2 1 0

23Downlink Quality (Inner toComplete)

N WORD 2 1 0

24Uplink Strength (Inner to

Complete)N WORD 2 1 0

25Downlink Strength (Inner to

Complete)N WORD 2 1 0

26 Distance (Inner to Complete) N WORD 2 1 0

27Better Cell (Inner toComplete)

N WORD 2 1 0

28Directed Retry (Inner to

Complete)N WORD 2 1 0

29Forced Handover due to O_M

(Inner to Complete)N WORD 2 1 0

30 Traffic (Inner to Complete) N WORD 2 1 0

31Fast Uplink (Inner toComplete)

N WORD 2 1 0

32

Forced Handover due to

Preemption (Inner to

Complete)

N WORD 2 1 0

46Forced HO due to DTM (Inner

to Complete)N WORD 2 1 0

33 Uplink Quality (Inner to Inner) N WORD 2 1 0

34Downlink Quality (Inner toInner)

N WORD 2 1 0

35Uplink Strength (Inner to

Inner)N WORD 2 1 0

36Downlink Strength (Inner to

Inner)N WORD 2 1 0

37 Distance (Inner to Inner) N WORD 2 1 0

38 Better Cell (Inner to Inner) N WORD 2 1 0

39 Directed Retry (Inner to Inner) N WORD 2 1 0

40Forced Handover due to O_M

(Inner to Inner)N WORD 2 1 0

41 Traffic (Inner to Inner) N WORD 2 1 0

42 Fast Uplink (Inner to Inner) N WORD 2 1 0

43 Forced Handover due to N WORD 2 1 0

Page 132: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 132/222

Preemption (Inner to Inner)

47Forced HO due to DTM (Inner

to Inner)

N WORD 2 1 0

Meas

Name:

(5,2)-- uNINHOIE--

Unsuccessful Internal

Handovers Intercell with

reconnection to old channel

per cause per neighbourcell

relationship

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 01 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

9 Fast Uplink N WORD 2 1 0

10Forced Handover due toPreemption

N WORD 2 1 0

Meas

Name:

(5,2)-- uNINHOIE--

Unsuccessful Internal

Handovers Intercell with

reconnection to old channel

per cause per neighbourcell

relationship

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell (PBGT) N WORD 2 1 0

Page 133: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 133/222

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Traffic N WORD 2 1 0

9 Fast Uplink N WORD 2 1 0

10Forced Handover due to

PreemptionN WORD 2 1 0

11 Forced HO due to DTM N WORD 2 1 0

scannerObjectClass: /BSS/SCANBTSOHON (6)

Meas

Name:

(6,0)-- aTINBHDO--Attempted Outgoing Inter

BSC Handovers per cause

per neighbour cell

relationship

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9Forced Handover due toPreemption

N WORD 2 1 0

Meas

Name:

(6,0)-- aTINBHDO--

Attempted Outgoing Inter

BSC Handovers per cause

per neighbour cell

relationship

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

Page 134: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 134/222

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9Forced Handover due to

PreemptionN WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

Meas

Name:

(6,1)-- sUINBHDO--

Successful Outgoing Inter

BSC Handovers per cause

per neighbour cell

relationship

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 02 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9Forced Handover due to

Preemption N WORD 2 1 0

Meas

Name:

(6,1)-- sUINBHDO--

Successful Outgoing Inter

BSC Handovers per cause

per neighbour cell

relationship

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 135: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 135/222

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9Forced Handover due to

PreemptionN WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

Meas

Name:

(6,2)-- nRUNINHD--

Number of Unsuccessful

Outgoing Inter BSC

Handovers per cause per

neighbour cell relationship

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 01 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9Forced Handover due to

PreemptionN WORD 2 1 0

Meas

Name:

(6,2)-- nRUNINHD--

Number of Unsuccessful

Outgoing Inter BSC

Handovers per cause per

neighbour cell relationship

Meas Set: 1

Counter Name Unit Type Size Scale Digit

Page 136: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 136/222

Id Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance (MS-BTS) N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7 Forced Handover due to O_M N WORD 2 1 0

8 Fast Uplink N WORD 2 1 0

9 Forced Handover due toPreemption N WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

scannerObjectClass: /BSS/SCANCHAN (7)

Meas

Name:

(7,0)-- pWRUPDW-- Power

and Quality measurements

on TCHs Uplink/Downlink

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Rxlev band 0 Uplink N WORD 2 1 0

1 Rxlev band 1 Uplink N WORD 2 1 0

2 Rxlev band 2 Uplink N WORD 2 1 0

3 Rxlev band 3 Uplink N WORD 2 1 0

4 Rxlev band 4 Uplink N WORD 2 1 0

5 Rxlev band 5 Uplink N WORD 2 1 0

6 Rxlev band 6 Uplink N WORD 2 1 07 Rxlev band 7 Uplink N WORD 2 1 0

8 Rxlev band 8 Uplink N WORD 2 1 0

9 Rxlev band 9 Uplink N WORD 2 1 0

10 Rxlev band 10 Uplink N WORD 2 1 0

11 Rxlev band 11 Uplink N WORD 2 1 0

12 Rxlev band 12 Uplink N WORD 2 1 0

13 Rxlev band 13 Uplink N WORD 2 1 0

Page 137: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 137/222

14 Rxlev band 14 Uplink N WORD 2 1 0

15 Rxlev band 15 Uplink N WORD 2 1 0

16 Rxlev band 16 Uplink N WORD 2 1 0

17 Rxlev band 17 Uplink N WORD 2 1 0

18 Rxlev band 18 Uplink N WORD 2 1 0

19 Rxlev band 19 Uplink N WORD 2 1 0

20 Rxlev band 20 Uplink N WORD 2 1 0

21 Rxlev band 21 Uplink N WORD 2 1 0

22 Rxlev band 22 Uplink N WORD 2 1 0

23 Rxlev band 23 Uplink N WORD 2 1 0

24 Rxlev band 24 Uplink N WORD 2 1 025 Rxlev band 25 Uplink N WORD 2 1 0

26 Rxlev band 26 Uplink N WORD 2 1 0

27 Rxlev band 27 Uplink N WORD 2 1 0

28 Rxlev band 28 Uplink N WORD 2 1 0

29 Rxlev band 29 Uplink N WORD 2 1 0

30 Rxlev band 30 Uplink N WORD 2 1 0

31 Rxlev band 31 Uplink N WORD 2 1 0

32 Rxlev band 32 Uplink N WORD 2 1 0

33 Rxlev band 33 Uplink N WORD 2 1 0

34 Rxlev band 34 Uplink N WORD 2 1 0

35 Rxlev band 35 Uplink N WORD 2 1 0

36 Rxlev band 36 Uplink N WORD 2 1 0

37 Rxlev band 37 Uplink N WORD 2 1 0

38 Rxlev band 38 Uplink N WORD 2 1 0

39 Rxlev band 39 Uplink N WORD 2 1 0

40 Rxlev band 40 Uplink N WORD 2 1 0

41 Rxlev band 41 Uplink N WORD 2 1 0

42 Rxlev band 42 Uplink N WORD 2 1 0

43 Rxlev band 43 Uplink N WORD 2 1 0

44 Rxlev band 44 Uplink N WORD 2 1 0

45 Rxlev band 45 Uplink N WORD 2 1 0

46 Rxlev band 46 Uplink N WORD 2 1 0

47 Rxlev band 47 Uplink N WORD 2 1 0

48 Rxlev band 48 Uplink N WORD 2 1 0

Page 138: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 138/222

49 Rxlev band 49 Uplink N WORD 2 1 0

50 Rxlev band 50 Uplink N WORD 2 1 0

51 Rxlev band 51 Uplink N WORD 2 1 0

52 Rxlev band 52 Uplink N WORD 2 1 0

53 Rxlev band 53 Uplink N WORD 2 1 0

54 Rxlev band 54 Uplink N WORD 2 1 0

55 Rxlev band 55 Uplink N WORD 2 1 0

56 Rxlev band 56 Uplink N WORD 2 1 0

57 Rxlev band 57 Uplink N WORD 2 1 0

58 Rxlev band 58 Uplink N WORD 2 1 0

59 Rxlev band 59 Uplink N WORD 2 1 060 Rxlev band 60 Uplink N WORD 2 1 0

61 Rxlev band 61 Uplink N WORD 2 1 0

62 Rxlev band 62 Uplink N WORD 2 1 0

63 Rxlev band 63 Uplink N WORD 2 1 0

64 Rxqual band 0 Uplink N WORD 2 1 0

65 Rxqual band 1 Uplink N WORD 2 1 0

66 Rxqual band 2 Uplink N WORD 2 1 0

67 Rxqual band 3 Uplink N WORD 2 1 0

68 Rxqual band 4 Uplink N WORD 2 1 0

69 Rxqual band 5 Uplink N WORD 2 1 0

70 Rxqual band 6 Uplink N WORD 2 1 0

71 Rxqual band 7 Uplink N WORD 2 1 0

Meas

Name:

(7,0)-- pWRUPDW-- Power

and Quality measurements

on TCHs Uplink/Downlink

Meas Set: 1

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

72 Rxlev band 0 Downlink N WORD 2 1 0

73 Rxlev band 1 Downlink N WORD 2 1 0

74 Rxlev band 2 Downlink N WORD 2 1 0

75 Rxlev band 3 Downlink N WORD 2 1 0

76 Rxlev band 4 Downlink N WORD 2 1 0

77 Rxlev band 5 Downlink N WORD 2 1 0

78 Rxlev band 6 Downlink N WORD 2 1 0

Page 139: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 139/222

79 Rxlev band 7 Downlink N WORD 2 1 0

80 Rxlev band 8 Downlink N WORD 2 1 0

81 Rxlev band 9 Downlink N WORD 2 1 0

82 Rxlev band 10 Downlink N WORD 2 1 0

83 Rxlev band 11 Downlink N WORD 2 1 0

84 Rxlev band 12 Downlink N WORD 2 1 0

85 Rxlev band 13 Downlink N WORD 2 1 0

86 Rxlev band 14 Downlink N WORD 2 1 0

87 Rxlev band 15 Downlink N WORD 2 1 0

88 Rxlev band 16 Downlink N WORD 2 1 0

89 Rxlev band 17 Downlink N WORD 2 1 090 Rxlev band 18 Downlink N WORD 2 1 0

91 Rxlev band 19 Downlink N WORD 2 1 0

92 Rxlev band 20 Downlink N WORD 2 1 0

93 Rxlev band 21 Downlink N WORD 2 1 0

94 Rxlev band 22 Downlink N WORD 2 1 0

95 Rxlev band 23 Downlink N WORD 2 1 0

96 Rxlev band 24 Downlink N WORD 2 1 0

97 Rxlev band 25 Downlink N WORD 2 1 0

98 Rxlev band 26 Downlink N WORD 2 1 0

99 Rxlev band 27 Downlink N WORD 2 1 0

100 Rxlev band 28 Downlink N WORD 2 1 0

101 Rxlev band 29 Downlink N WORD 2 1 0

102 Rxlev band 30 Downlink N WORD 2 1 0

103 Rxlev band 31 Downlink N WORD 2 1 0

104 Rxlev band 32 Downlink N WORD 2 1 0

105 Rxlev band 33 Downlink N WORD 2 1 0

106 Rxlev band 34 Downlink N WORD 2 1 0

107 Rxlev band 35 Downlink N WORD 2 1 0

108 Rxlev band 36 Downlink N WORD 2 1 0

109 Rxlev band 37 Downlink N WORD 2 1 0

110 Rxlev band 38 Downlink N WORD 2 1 0

111 Rxlev band 39 Downlink N WORD 2 1 0

112 Rxlev band 40 Downlink N WORD 2 1 0

113 Rxlev band 41 Downlink N WORD 2 1 0

Page 140: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 140/222

114 Rxlev band 42 Downlink N WORD 2 1 0

115 Rxlev band 43 Downlink N WORD 2 1 0

116 Rxlev band 44 Downlink N WORD 2 1 0

117 Rxlev band 45 Downlink N WORD 2 1 0

118 Rxlev band 46 Downlink N WORD 2 1 0

119 Rxlev band 47 Downlink N WORD 2 1 0

120 Rxlev band 48 Downlink N WORD 2 1 0

121 Rxlev band 49 Downlink N WORD 2 1 0

122 Rxlev band 50 Downlink N WORD 2 1 0

123 Rxlev band 51 Downlink N WORD 2 1 0

124 Rxlev band 52 Downlink N WORD 2 1 0125 Rxlev band 53 Downlink N WORD 2 1 0

126 Rxlev band 54 Downlink N WORD 2 1 0

127 Rxlev band 55 Downlink N WORD 2 1 0

128 Rxlev band 56 Downlink N WORD 2 1 0

129 Rxlev band 57 Downlink N WORD 2 1 0

130 Rxlev band 58 Downlink N WORD 2 1 0

131 Rxlev band 59 Downlink N WORD 2 1 0

132 Rxlev band 60 Downlink N WORD 2 1 0

133 Rxlev band 61 Downlink N WORD 2 1 0

134 Rxlev band 62 Downlink N WORD 2 1 0

135 Rxlev band 63 Downlink N WORD 2 1 0

136 Rxqual band 0 Downlink N WORD 2 1 0

137 Rxqual band 1 Downlink N WORD 2 1 0

138 Rxqual band 2 Downlink N WORD 2 1 0

139 Rxqual band 3 Downlink N WORD 2 1 0

140 Rxqual band 4 Downlink N WORD 2 1 0

141 Rxqual band 5 Downlink N WORD 2 1 0

142 Rxqual band 6 Downlink N WORD 2 1 0

143 Rxqual band 7 Downlink N WORD 2 1 0

Meas

Name:

(7,0)-- pWRUPDW-- Power

and Quality measurements on

TCHs Uplink/Downlink

Meas Set: 255

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 141: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 141/222

scannerObjectClass: /BSS/SCANCTRX (8)

Meas

Name:

(8,0)-- cRXLVQUU--

Correlated RXLEV to

RXQUAL measurements

(Uplink)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 RxLev 0 - RxQual 0 Uplink N WORD 2 1 0

1 RxLev 0 - RxQual 1 Uplink N WORD 2 1 0

2 RxLev 0 - RxQual 2 Uplink N WORD 2 1 0

3 RxLev 0 - RxQual 3 Uplink N WORD 2 1 0

4 RxLev 0 - RxQual 4 Uplink N WORD 2 1 0

5 RxLev 0 - RxQual 5 Uplink N WORD 2 1 0

6 RxLev 0 - RxQual 6 Uplink N WORD 2 1 0

7 RxLev 0 - RxQual 7 Uplink N WORD 2 1 0

8 RxLev 1 - RxQual 0 Uplink N WORD 2 1 0

9 RxLev 1 - RxQual 1 Uplink N WORD 2 1 0

10 RxLev 1 - RxQual 2 Uplink N WORD 2 1 0

11 RxLev 1 - RxQual 3 Uplink N WORD 2 1 0

12 RxLev 1 - RxQual 4 Uplink N WORD 2 1 0

13 RxLev 1 - RxQual 5 Uplink N WORD 2 1 0

14 RxLev 1 - RxQual 6 Uplink N WORD 2 1 0

15 RxLev 1 - RxQual 7 Uplink N WORD 2 1 0

16 RxLev 2 - RxQual 0 Uplink N WORD 2 1 0

17 RxLev 2 - RxQual 1 Uplink N WORD 2 1 0

18 RxLev 2 - RxQual 2 Uplink N WORD 2 1 0

19 RxLev 2 - RxQual 3 Uplink N WORD 2 1 020 RxLev 2 - RxQual 4 Uplink N WORD 2 1 0

21 RxLev 2 - RxQual 5 Uplink N WORD 2 1 0

22 RxLev 2 - RxQual 6 Uplink N WORD 2 1 0

23 RxLev 2 - RxQual 7 Uplink N WORD 2 1 0

24 RxLev 3 - RxQual 0 Uplink N WORD 2 1 0

25 RxLev 3 - RxQual 1 Uplink N WORD 2 1 0

26 RxLev 3 - RxQual 2 Uplink N WORD 2 1 0

Page 142: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 142/222

27 RxLev 3 - RxQual 3 Uplink N WORD 2 1 0

28 RxLev 3 - RxQual 4 Uplink N WORD 2 1 0

29 RxLev 3 - RxQual 5 Uplink N WORD 2 1 0

30 RxLev 3 - RxQual 6 Uplink N WORD 2 1 0

31 RxLev 3 - RxQual 7 Uplink N WORD 2 1 0

32 RxLev 4 - RxQual 0 Uplink N WORD 2 1 0

33 RxLev 4 - RxQual 1 Uplink N WORD 2 1 0

34 RxLev 4 - RxQual 2 Uplink N WORD 2 1 0

35 RxLev 4 - RxQual 3 Uplink N WORD 2 1 0

36 RxLev 4 - RxQual 4 Uplink N WORD 2 1 0

37 RxLev 4 - RxQual 5 Uplink N WORD 2 1 038 RxLev 4 - RxQual 6 Uplink N WORD 2 1 0

39 RxLev 4 - RxQual 7 Uplink N WORD 2 1 0

40 RxLev 5 - RxQual 0 Uplink N WORD 2 1 0

41 RxLev 5 - RxQual 1 Uplink N WORD 2 1 0

42 RxLev 5 - RxQual 2 Uplink N WORD 2 1 0

43 RxLev 5 - RxQual 3 Uplink N WORD 2 1 0

44 RxLev 5 - RxQual 4 Uplink N WORD 2 1 0

45 RxLev 5 - RxQual 5 Uplink N WORD 2 1 0

46 RxLev 5 - RxQual 6 Uplink N WORD 2 1 0

47 RxLev 5 - RxQual 7 Uplink N WORD 2 1 0

48 RxLev 6 - RxQual 0 Uplink N WORD 2 1 0

49 RxLev 6 - RxQual 1 Uplink N WORD 2 1 0

50 RxLev 6 - RxQual 2 Uplink N WORD 2 1 0

51 RxLev 6 - RxQual 3 Uplink N WORD 2 1 0

52 RxLev 6 - RxQual 4 Uplink N WORD 2 1 0

53 RxLev 6 - RxQual 5 Uplink N WORD 2 1 0

54 RxLev 6 - RxQual 6 Uplink N WORD 2 1 0

55 RxLev 6 - RxQual 7 Uplink N WORD 2 1 0

56 RxLev 7 - RxQual 0 Uplink N WORD 2 1 0

57 RxLev 7 - RxQual 1 Uplink N WORD 2 1 0

58 RxLev 7 - RxQual 2 Uplink N WORD 2 1 0

59 RxLev 7 - RxQual 3 Uplink N WORD 2 1 0

60 RxLev 7 - RxQual 4 Uplink N WORD 2 1 0

61 RxLev 7 - RxQual 5 Uplink N WORD 2 1 0

Page 143: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 143/222

62 RxLev 7 - RxQual 6 Uplink N WORD 2 1 0

63 RxLev 7 - RxQual 7 Uplink N WORD 2 1 0

Meas

Name:

(8,1)-- cRXLVQUD--

Correlated RXLEV to

RXQUAL measurements

(Downlink)

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 RxLev 0 - RxQual 0 Downlink N WORD 2 1 0

1 RxLev 0 - RxQual 1 Downlink N WORD 2 1 0

2 RxLev 0 - RxQual 2 Downlink N WORD 2 1 03 RxLev 0 - RxQual 3 Downlink N WORD 2 1 0

4 RxLev 0 - RxQual 4 Downlink N WORD 2 1 0

5 RxLev 0 - RxQual 5 Downlink N WORD 2 1 0

6 RxLev 0 - RxQual 6 Downlink N WORD 2 1 0

7 RxLev 0 - RxQual 7 Downlink N WORD 2 1 0

8 RxLev 1 - RxQual 0 Downlink N WORD 2 1 0

9 RxLev 1 - RxQual 1 Downlink N WORD 2 1 0

10 RxLev 1 - RxQual 2 Downlink N WORD 2 1 0

11 RxLev 1 - RxQual 3 Downlink N WORD 2 1 0

12 RxLev 1 - RxQual 4 Downlink N WORD 2 1 0

13 RxLev 1 - RxQual 5 Downlink N WORD 2 1 0

14 RxLev 1 - RxQual 6 Downlink N WORD 2 1 0

15 RxLev 1 - RxQual 7 Downlink N WORD 2 1 0

16 RxLev 2 - RxQual 0 Downlink N WORD 2 1 0

17 RxLev 2 - RxQual 1 Downlink N WORD 2 1 0

18 RxLev 2 - RxQual 2 Downlink N WORD 2 1 0

19 RxLev 2 - RxQual 3 Downlink N WORD 2 1 0

20 RxLev 2 - RxQual 4 Downlink N WORD 2 1 0

21 RxLev 2 - RxQual 5 Downlink N WORD 2 1 0

22 RxLev 2 - RxQual 6 Downlink N WORD 2 1 0

23 RxLev 2 - RxQual 7 Downlink N WORD 2 1 0

24 RxLev 3 - RxQual 0 Downlink N WORD 2 1 0

25 RxLev 3 - RxQual 1 Downlink N WORD 2 1 0

26 RxLev 3 - RxQual 2 Downlink N WORD 2 1 0

Page 144: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 144/222

27 RxLev 3 - RxQual 3 Downlink N WORD 2 1 0

28 RxLev 3 - RxQual 4 Downlink N WORD 2 1 0

29 RxLev 3 - RxQual 5 Downlink N WORD 2 1 0

30 RxLev 3 - RxQual 6 Downlink N WORD 2 1 0

31 RxLev 3 - RxQual 7 Downlink N WORD 2 1 0

32 RxLev 4 - RxQual 0 Downlink N WORD 2 1 0

33 RxLev 4 - RxQual 1 Downlink N WORD 2 1 0

34 RxLev 4 - RxQual 2 Downlink N WORD 2 1 0

35 RxLev 4 - RxQual 3 Downlink N WORD 2 1 0

36 RxLev 4 - RxQual 4 Downlink N WORD 2 1 0

37 RxLev 4 - RxQual 5 Downlink N WORD 2 1 038 RxLev 4 - RxQual 6 Downlink N WORD 2 1 0

39 RxLev 4 - RxQual 7 Downlink N WORD 2 1 0

40 RxLev 5 - RxQual 0 Downlink N WORD 2 1 0

41 RxLev 5 - RxQual 1 Downlink N WORD 2 1 0

42 RxLev 5 - RxQual 2 Downlink N WORD 2 1 0

43 RxLev 5 - RxQual 3 Downlink N WORD 2 1 0

44 RxLev 5 - RxQual 4 Downlink N WORD 2 1 0

45 RxLev 5 - RxQual 5 Downlink N WORD 2 1 0

46 RxLev 5 - RxQual 6 Downlink N WORD 2 1 0

47 RxLev 5 - RxQual 7 Downlink N WORD 2 1 0

48 RxLev 6 - RxQual 0 Downlink N WORD 2 1 0

49 RxLev 6 - RxQual 1 Downlink N WORD 2 1 0

50 RxLev 6 - RxQual 2 Downlink N WORD 2 1 0

51 RxLev 6 - RxQual 3 Downlink N WORD 2 1 0

52 RxLev 6 - RxQual 4 Downlink N WORD 2 1 0

53 RxLev 6 - RxQual 5 Downlink N WORD 2 1 0

54 RxLev 6 - RxQual 6 Downlink N WORD 2 1 0

55 RxLev 6 - RxQual 7 Downlink N WORD 2 1 0

56 RxLev 7 - RxQual 0 Downlink N WORD 2 1 0

57 RxLev 7 - RxQual 1 Downlink N WORD 2 1 0

58 RxLev 7 - RxQual 2 Downlink N WORD 2 1 0

59 RxLev 7 - RxQual 3 Downlink N WORD 2 1 0

60 RxLev 7 - RxQual 4 Downlink N WORD 2 1 0

61 RxLev 7 - RxQual 5 Downlink N WORD 2 1 0

Page 145: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 145/222

62 RxLev 7 - RxQual 6 Downlink N WORD 2 1 0

63 RxLev 7 - RxQual 7 Downlink N WORD 2 1 0

Meas

Name:

(8,2)-- cRXLVTAU--

Correlated RXLEV to Time

Advance measurements

(Uplink)

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 RxLev 0 - TA 0 Uplink N WORD 2 1 0

1 RxLev 0 - TA 1 Uplink N WORD 2 1 0

2 RxLev 0 - TA 2 Uplink N WORD 2 1 03 RxLev 0 - TA 3 Uplink N WORD 2 1 0

4 RxLev 0 - TA 4 Uplink N WORD 2 1 0

5 RxLev 0 - TA 5 Uplink N WORD 2 1 0

6 RxLev 0 - TA 6 Uplink N WORD 2 1 0

7 RxLev 0 - TA 7 Uplink N WORD 2 1 0

8 RxLev 1 - TA 0 Uplink N WORD 2 1 0

9 RxLev 1 - TA 1 Uplink N WORD 2 1 0

10 RxLev 1 - TA 2 Uplink N WORD 2 1 0

11 RxLev 1 - TA 3 Uplink N WORD 2 1 0

12 RxLev 1 - TA 4 Uplink N WORD 2 1 0

13 RxLev 1 - TA 5 Uplink N WORD 2 1 0

14 RxLev 1 - TA 6 Uplink N WORD 2 1 0

15 RxLev 1 - TA 7 Uplink N WORD 2 1 0

16 RxLev 2 - TA 0 Uplink N WORD 2 1 0

17 RxLev 2 - TA 1 Uplink N WORD 2 1 0

18 RxLev 2 - TA 2 Uplink N WORD 2 1 0

19 RxLev 2 - TA 3 Uplink N WORD 2 1 0

20 RxLev 2 - TA 4 Uplink N WORD 2 1 0

21 RxLev 2 - TA 5 Uplink N WORD 2 1 0

22 RxLev 2 - TA 6 Uplink N WORD 2 1 0

23 RxLev 2 - TA 7 Uplink N WORD 2 1 0

24 RxLev 3 - TA 0 Uplink N WORD 2 1 0

25 RxLev 3 - TA 1 Uplink N WORD 2 1 0

26 RxLev 3 - TA 2 Uplink N WORD 2 1 0

Page 146: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 146/222

27 RxLev 3 - TA 3 Uplink N WORD 2 1 0

28 RxLev 3 - TA 4 Uplink N WORD 2 1 0

29 RxLev 3 - TA 5 Uplink N WORD 2 1 0

30 RxLev 3 - TA 6 Uplink N WORD 2 1 0

31 RxLev 3 - TA 7 Uplink N WORD 2 1 0

32 RxLev 4 - TA 0 Uplink N WORD 2 1 0

33 RxLev 4 - TA 1 Uplink N WORD 2 1 0

34 RxLev 4 - TA 2 Uplink N WORD 2 1 0

35 RxLev 4 - TA 3 Uplink N WORD 2 1 0

36 RxLev 4 - TA 4 Uplink N WORD 2 1 0

37 RxLev 4 - TA 5 Uplink N WORD 2 1 038 RxLev 4 - TA 6 Uplink N WORD 2 1 0

39 RxLev 4 - TA 7 Uplink N WORD 2 1 0

40 RxLev 5 - TA 0 Uplink N WORD 2 1 0

41 RxLev 5 - TA 1 Uplink N WORD 2 1 0

42 RxLev 5 - TA 2 Uplink N WORD 2 1 0

43 RxLev 5 - TA 3 Uplink N WORD 2 1 0

44 RxLev 5 - TA 4 Uplink N WORD 2 1 0

45 RxLev 5 - TA 5 Uplink N WORD 2 1 0

46 RxLev 5 - TA 6 Uplink N WORD 2 1 0

47 RxLev 5 - TA 7 Uplink N WORD 2 1 0

48 RxLev 6 - TA 0 Uplink N WORD 2 1 0

49 RxLev 6 - TA 1 Uplink N WORD 2 1 0

50 RxLev 6 - TA 2 Uplink N WORD 2 1 0

51 RxLev 6 - TA 3 Uplink N WORD 2 1 0

52 RxLev 6 - TA 4 Uplink N WORD 2 1 0

53 RxLev 6 - TA 5 Uplink N WORD 2 1 0

54 RxLev 6 - TA 6 Uplink N WORD 2 1 0

55 RxLev 6 - TA 7 Uplink N WORD 2 1 0

56 RxLev 7 - TA 0 Uplink N WORD 2 1 0

57 RxLev 7 - TA 1 Uplink N WORD 2 1 0

58 RxLev 7 - TA 2 Uplink N WORD 2 1 0

59 RxLev 7 - TA 3 Uplink N WORD 2 1 0

60 RxLev 7 - TA 4 Uplink N WORD 2 1 0

61 RxLev 7 - TA 5 Uplink N WORD 2 1 0

Page 147: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 147/222

62 RxLev 7 - TA 6 Uplink N WORD 2 1 0

63 RxLev 7 - TA 7 Uplink N WORD 2 1 0

Meas

Name:

(8,3)-- cRXLVTAD--

Correlated RXLEV to Time

Advance measurements

(Downlink)

Meas Set: 3

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 RxLev 0 - TA 0 Downlink N WORD 2 1 0

1 RxLev 0 - TA 1 Downlink N WORD 2 1 0

2 RxLev 0 - TA 2 Downlink N WORD 2 1 03 RxLev 0 - TA 3 Downlink N WORD 2 1 0

4 RxLev 0 - TA 4 Downlink N WORD 2 1 0

5 RxLev 0 - TA 5 Downlink N WORD 2 1 0

6 RxLev 0 - TA 6 Downlink N WORD 2 1 0

7 RxLev 0 - TA 7 Downlink N WORD 2 1 0

8 RxLev 1 - TA 0 Downlink N WORD 2 1 0

9 RxLev 1 - TA 1 Downlink N WORD 2 1 0

10 RxLev 1 - TA 2 Downlink N WORD 2 1 0

11 RxLev 1 - TA 3 Downlink N WORD 2 1 0

12 RxLev 1 - TA 4 Downlink N WORD 2 1 0

13 RxLev 1 - TA 5 Downlink N WORD 2 1 0

14 RxLev 1 - TA 6 Downlink N WORD 2 1 0

15 RxLev 1 - TA 7 Downlink N WORD 2 1 0

16 RxLev 2 - TA 0 Downlink N WORD 2 1 0

17 RxLev 2 - TA 1 Downlink N WORD 2 1 0

18 RxLev 2 - TA 2 Downlink N WORD 2 1 0

19 RxLev 2 - TA 3 Downlink N WORD 2 1 0

20 RxLev 2 - TA 4 Downlink N WORD 2 1 0

21 RxLev 2 - TA 5 Downlink N WORD 2 1 0

22 RxLev 2 - TA 6 Downlink N WORD 2 1 0

23 RxLev 2 - TA 7 Downlink N WORD 2 1 0

24 RxLev 3 - TA 0 Downlink N WORD 2 1 0

25 RxLev 3 - TA 1 Downlink N WORD 2 1 0

26 RxLev 3 - TA 2 Downlink N WORD 2 1 0

Page 148: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 148/222

27 RxLev 3 - TA 3 Downlink N WORD 2 1 0

28 RxLev 3 - TA 4 Downlink N WORD 2 1 0

29 RxLev 3 - TA 5 Downlink N WORD 2 1 0

30 RxLev 3 - TA 6 Downlink N WORD 2 1 0

31 RxLev 3 - TA 7 Downlink N WORD 2 1 0

32 RxLev 4 - TA 0 Downlink N WORD 2 1 0

33 RxLev 4 - TA 1 Downlink N WORD 2 1 0

34 RxLev 4 - TA 2 Downlink N WORD 2 1 0

35 RxLev 4 - TA 3 Downlink N WORD 2 1 0

36 RxLev 4 - TA 4 Downlink N WORD 2 1 0

37 RxLev 4 - TA 5 Downlink N WORD 2 1 038 RxLev 4 - TA 6 Downlink N WORD 2 1 0

39 RxLev 4 - TA 7 Downlink N WORD 2 1 0

40 RxLev 5 - TA 0 Downlink N WORD 2 1 0

41 RxLev 5 - TA 1 Downlink N WORD 2 1 0

42 RxLev 5 - TA 2 Downlink N WORD 2 1 0

43 RxLev 5 - TA 3 Downlink N WORD 2 1 0

44 RxLev 5 - TA 4 Downlink N WORD 2 1 0

45 RxLev 5 - TA 5 Downlink N WORD 2 1 0

46 RxLev 5 - TA 6 Downlink N WORD 2 1 0

47 RxLev 5 - TA 7 Downlink N WORD 2 1 0

48 RxLev 6 - TA 0 Downlink N WORD 2 1 0

49 RxLev 6 - TA 1 Downlink N WORD 2 1 0

50 RxLev 6 - TA 2 Downlink N WORD 2 1 0

51 RxLev 6 - TA 3 Downlink N WORD 2 1 0

52 RxLev 6 - TA 4 Downlink N WORD 2 1 0

53 RxLev 6 - TA 5 Downlink N WORD 2 1 0

54 RxLev 6 - TA 6 Downlink N WORD 2 1 0

55 RxLev 6 - TA 7 Downlink N WORD 2 1 0

56 RxLev 7 - TA 0 Downlink N WORD 2 1 0

57 RxLev 7 - TA 1 Downlink N WORD 2 1 0

58 RxLev 7 - TA 2 Downlink N WORD 2 1 0

59 RxLev 7 - TA 3 Downlink N WORD 2 1 0

60 RxLev 7 - TA 4 Downlink N WORD 2 1 0

61 RxLev 7 - TA 5 Downlink N WORD 2 1 0

Page 149: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 149/222

62 RxLev 7 - TA 6 Downlink N WORD 2 1 0

63 RxLev 7 - TA 7 Downlink N WORD 2 1 0

Meas

Name:

(8,4)-- cFERRXQU--

Correlated FER to

RXQUAL measurements

Meas Set: 4

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0FER 0 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

1FER 0 - RxQual 1

ServiceType 1,2 or 3N WORD 2 1 0

2FER 0 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

3FER 0 - RxQual 3ServiceType 1,2 or 3

N WORD 2 1 0

4FER 0 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

5FER 0 - RxQual 5ServiceType 1,2 or 3

N WORD 2 1 0

6FER 0 - RxQual 6

ServiceType 1,2 or 3

N WORD 2 1 0

7FER 0 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

8FER 1 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

9FER 1 - RxQual 1

ServiceType 1,2 or 3N WORD 2 1 0

10FER 1 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

11FER 1 - RxQual 3ServiceType 1,2 or 3 N WORD 2 1 0

12FER 1 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

13FER 1 - RxQual 5

ServiceType 1,2 or 3N WORD 2 1 0

14FER 1 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

15FER 1 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

Page 150: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 150/222

16FER 2 - RxQual 0ServiceType 1,2 or 3

N WORD 2 1 0

17 FER 2 - RxQual 1ServiceType 1,2 or 3

N WORD 2 1 0

18FER 2 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

19FER 2 - RxQual 3

ServiceType 1,2 or 3N WORD 2 1 0

20FER 2 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

21FER 2 - RxQual 5ServiceType 1,2 or 3

N WORD 2 1 0

22FER 2 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

23FER 2 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

24FER 3 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

25FER 3 - RxQual 1

ServiceType 1,2 or 3N WORD 2 1 0

26FER 3 - RxQual 2

ServiceType 1,2 or 3

N WORD 2 1 0

27FER 3 - RxQual 3ServiceType 1,2 or 3

N WORD 2 1 0

28FER 3 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

29FER 3 - RxQual 5ServiceType 1,2 or 3

N WORD 2 1 0

30FER 3 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

31

FER 3 - RxQual 7

ServiceType 1,2 or 3 N WORD 2 1 0

32FER 4 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

33FER 4 - RxQual 1

ServiceType 1,2 or 3N WORD 2 1 0

34FER 4 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

35FER 4 - RxQual 3

ServiceType 1,2 or 3N WORD 2 1 0

Page 151: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 151/222

36FER 4 - RxQual 4ServiceType 1,2 or 3

N WORD 2 1 0

37 FER 4 - RxQual 5ServiceType 1,2 or 3

N WORD 2 1 0

38FER 4 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

39FER 4 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

40FER 5 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

41FER 5 - RxQual 1ServiceType 1,2 or 3

N WORD 2 1 0

42FER 5 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

43FER 5 - RxQual 3

ServiceType 1,2 or 3N WORD 2 1 0

44FER 5 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

45FER 5 - RxQual 5

ServiceType 1,2 or 3N WORD 2 1 0

46FER 5 - RxQual 6

ServiceType 1,2 or 3

N WORD 2 1 0

47FER 5 - RxQual 7ServiceType 1,2 or 3

N WORD 2 1 0

48FER 6 - RxQual 0

ServiceType 1,2 or 3N WORD 2 1 0

49FER 6 - RxQual 1ServiceType 1,2 or 3

N WORD 2 1 0

50FER 6 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

51

FER 6 - RxQual 3

ServiceType 1,2 or 3 N WORD 2 1 0

52FER 6 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

53FER 6 - RxQual 5

ServiceType 1,2 or 3N WORD 2 1 0

54FER 6 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

55FER 6 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

Page 152: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 152/222

56FER 7 - RxQual 0ServiceType 1,2 or 3

N WORD 2 1 0

57 FER 7 - RxQual 1ServiceType 1,2 or 3

N WORD 2 1 0

58FER 7 - RxQual 2

ServiceType 1,2 or 3N WORD 2 1 0

59FER 7 - RxQual 3

ServiceType 1,2 or 3N WORD 2 1 0

60FER 7 - RxQual 4

ServiceType 1,2 or 3N WORD 2 1 0

61FER 7 - RxQual 5ServiceType 1,2 or 3

N WORD 2 1 0

62FER 7 - RxQual 6

ServiceType 1,2 or 3N WORD 2 1 0

63FER 7 - RxQual 7

ServiceType 1,2 or 3N WORD 2 1 0

scannerObjectClass: /BSS/SCANGPRS (9)

Meas

Name:

(9,0)-- nAVPDCH-- Min,

Max, Mean number of available PDCHs per cell Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Minimum number of available

PDCHN WORD 2 1 0

1Maximum number of available

PDCHN WORD 2 1 0

2Mean number of available

PDCHN LONG 4 1000 2

Meas

Name:

(9,1)-- rEJPDASS-- Number

of rejected PDCH

assignments

(uplink/downlink) per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0No radio resource available for

an Uplink TBFN LONG 4 1 0

Page 153: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 153/222

1 Others for an Uplink TBF N LONG 4 1 0

2No radio resource available for

a Downlink TBF

N LONG 4 1 0

3 Others for a Downlink TBF N LONG 4 1 0

Meas

Name:

(9,1)-- rEJPDASS-- Number

of rejected PDCH

assignments

(uplink/downlink) per cause

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

4

No Abis subchannel available

for an uplink TBF N LONG 4 1 0

5No PDT at PCU available for

an uplink TBFN LONG 4 1 0

0No radio resource available foran Uplink TBF

N LONG 4 1 0

1 Others for an Uplink TBF N LONG 4 1 0

6No Abis subchannel availablefor a downlink TBF

N LONG 4 1 0

7No PDT at PCU available for a

downlink TBF

N LONG 4 1 0

2No radio resource available for

a Downlink TBFN LONG 4 1 0

3 Others for a Downlink TBF N LONG 4 1 0

Meas

Name:

(9,1)-- rEJPDASS-- Number

of rejected PDCH

assignments

(uplink/downlink) per cause

Meas Set: 2

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

8

No Abis subchannel available

for a uplink TBF for Interactiveservices

N LONG 4 1 0

9No Abis subchannel availablefor a uplink TBF for Streaming

services

N LONG 4 1 0

10No Abis subchannel available

for a uplink TBF forN LONG 4 1 0

Page 154: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 154/222

Background services

11

No PDT at PCU available for a

uplink TBF for Interactiveservices

N LONG 4 1 0

12

No PDT at PCU available for a

uplink TBF for Streaming

services

N LONG 4 1 0

13

No PDT at PCU available for a

uplink TBF for Background

services

N LONG 4 1 0

14No radio resource available foran Uplink TBF for Interactive

services

N LONG 4 1 0

15No radio resource available foran Uplink TBF for Streaming

services

N LONG 4 1 0

16

No radio resource available for

an Uplink TBF for Backgroundservices

N LONG 4 1 0

17Others for an Uplink TBF for

Interactive servicesN LONG 4 1 0

18Others for an Uplink TBF for

Streaming servicesN LONG 4 1 0

19Others for an Uplink TBF for

Background servicesN LONG 4 1 0

20No Abis subchannel availablefor a downlink TBF for

Interactive services

N LONG 4 1 0

21

No Abis subchannel available

for a downlink TBF for

Streaming services

N LONG 4 1 0

22

No Abis subchannel available

for a downlink TBF forBackground services

N LONG 4 1 0

23No PDT at PCU available for adownlink TBF for Interactive

services

N LONG 4 1 0

24

No PDT at PCU available for a

downlink TBF for Streaming

services

N LONG 4 1 0

25 No PDT at PCU available for a N LONG 4 1 0

Page 155: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 155/222

downlink TBF for Backgroundservices

26No radio resource available foran Downlink TBF for

Interactive services

N LONG 4 1 0

27

No radio resource available for

an Downlink TBF for

Streaming services

N LONG 4 1 0

28

No radio resource available for

an Downlink TBF forBackground services

N LONG 4 1 0

29Others for an Downlink TBF

for Interactive services

N LONG 4 1 0

30Others for an Downlink TBFfor Streaming services

N LONG 4 1 0

31Others for an Downlink TBF

for Background servicesN LONG 4 1 0

32Short Timer expiration for UL

TBFN LONG 4 1 0

Meas

Name:

(9,2)-- nUACATCL--

Number of attempted PDCH

assignments(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Attempted PDCH assignments

for an Uplink TBFN LONG 4 1 0

1Attempted PDCH assignments

for a Downlink TBFN LONG 4 1 0

Meas

Name:

(9,2)-- nUACATCL--Number of attempted PDCH

assignments

(uplink/downlink) per cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

2Attempted PDCH assignmentsfor a Uplink TBF for

Interactive services

N LONG 4 1 0

3 Attempted PDCH assignments N LONG 4 1 0

Page 156: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 156/222

for a Uplink TBF for Streamingservices

4Attempted PDCH assignmentsfor a Uplink TBF for

Background services

N LONG 4 1 0

5

Attempted PDCH assignments

for a Downlink TBF for

Interactive services

N LONG 4 1 0

6

Attempted PDCH assignments

for a Downlink TBF forStreaming services

N LONG 4 1 0

7

Attempted PDCH assignments

for a Downlink TBF forBackground services N LONG 4 1 0

Meas

Name:

(9,3)-- sULACCEL-- Number

of successful PDCH seizures

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of successful PDCH

seizures for an Uplink TBFN LONG 4 1 0

1 Number of successful PDCHseizures for a Downlink TBF

N LONG 4 1 0

Meas

Name:

(9,3)-- sULACCEL-- Number

of successful PDCH seizures

(uplink/downlink) per cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

2

Number of successful PDCH

seizures for an Uplink TBF for

Interactive services

N LONG 4 1 0

3Number of successful PDCHseizures for an Uplink TBF for

Streaming services

N LONG 4 1 0

4

Number of successful PDCH

seizures for an Uplink TBF for

Background services

N LONG 4 1 0

5Number of successful PDCH

seizures for an Downlink TBFN LONG 4 1 0

Page 157: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 157/222

for Interactive services

6

Number of successful PDCH

seizures for an Downlink TBFfor Streaming services

N LONG 4 1 0

7

Number of successful PDCH

seizures for an Downlink TBF

for Background services

N LONG 4 1 0

Meas

Name:

(9,4)-- nRETPDU-- Number

of retransmitted PDUs

(uplink/downlink) per coding

scheme per cell on the RF

interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 CS-1 Uplink N LONG 4 1 0

1 CS-2 Uplink N LONG 4 1 0

2 CS-3 Uplink N LONG 4 1 0

3 CS-4 Uplink N LONG 4 1 0

4 MCS-1 Uplink N LONG 4 1 0

5 MCS-2 Uplink N LONG 4 1 0

6 MCS-3 Uplink N LONG 4 1 0

7 MCS-4 Uplink N LONG 4 1 0

8 MCS-5 Uplink N LONG 4 1 0

9 MCS-6 Uplink N LONG 4 1 0

10 MCS-7 Uplink N LONG 4 1 0

11 MCS-8 Uplink N LONG 4 1 0

12 MCS-9 Uplink N LONG 4 1 0

13 CS-1 Downlink N LONG 4 1 0

14 CS-2 Downlink N LONG 4 1 015 CS-3 Downlink N LONG 4 1 0

16 CS-4 Downlink N LONG 4 1 0

17 MCS-1 Downlink N LONG 4 1 0

18 MCS-2 Downlink N LONG 4 1 0

19 MCS-3 Downlink N LONG 4 1 0

20 MCS-4 Downlink N LONG 4 1 0

21 MCS-5 Downlink N LONG 4 1 0

Page 158: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 158/222

22 MCS-6 Downlink N LONG 4 1 0

23 MCS-7 Downlink N LONG 4 1 0

24 MCS-8 Downlink N LONG 4 1 0

25 MCS-9 Downlink N LONG 4 1 0

Meas

Name:

(9,5)-- nTDMPPCH--

Number of transmitted and

discarded messages on the

PPCH per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of transmittedmessages on the PPCH for CS

traffic

N LONG 4 1 0

1Number of transmittedmessages on the PPCH for PStraffic

N LONG 4 1 0

2

Number of messages discardedfrom the packet paging queue

for CS trafficN LONG 4 1 0

3

Number of messages discarded

from the packet paging queue

for PS traffic

N LONG 4 1 0

Meas

Name:

(9,6)-- nSUGPPAG-- Number

of successful GPRS paging

procedures

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of successful GPRS

paging proceduresN LONG 4 1 0

Meas

Name:

(9,7)-- mUTHRF-- Mean

user data throughput

(uplink/downlink) per

coding scheme per cell on

the RF interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 CS-1 Uplink byte/s LONG 4 1000 2

Page 159: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 159/222

1 CS-2 Uplink byte/s LONG 4 1000 2

2 CS-3 Uplink byte/s LONG 4 1000 2

3 CS-4 Uplink byte/s LONG 4 1000 2

4 MCS-1 Uplink byte/s LONG 4 1000 2

5 MCS-2 Uplink byte/s LONG 4 1000 2

6 MCS-3 Uplink byte/s LONG 4 1000 2

7 MCS-4 Uplink byte/s LONG 4 1000 2

8 MCS-5 Uplink byte/s LONG 4 1000 2

9 MCS-6 Uplink byte/s LONG 4 1000 2

10 MCS-7 Uplink byte/s LONG 4 1000 2

11 MCS-8 Uplink byte/s LONG 4 1000 212 MCS-9 Uplink byte/s LONG 4 1000 2

13 CS-1 Downlink byte/s LONG 4 1000 2

14 CS-2 Downlink byte/s LONG 4 1000 2

15 CS-3 Downlink byte/s LONG 4 1000 2

16 CS-4 Downlink byte/s LONG 4 1000 2

17 MCS-1 Downlink byte/s LONG 4 1000 2

18 MCS-2 Downlink byte/s LONG 4 1000 2

19 MCS-3 Downlink byte/s LONG 4 1000 2

20 MCS-4 Downlink byte/s LONG 4 1000 2

21 MCS-5 Downlink byte/s LONG 4 1000 2

22 MCS-6 Downlink byte/s LONG 4 1000 2

23 MCS-7 Downlink byte/s LONG 4 1000 2

24 MCS-8 Downlink byte/s LONG 4 1000 2

25 MCS-9 Downlink byte/s LONG 4 1000 2

MeasName:

(9,8)-- mSTHRF-- Mean

signalling data throughput(uplink/downlink) per cell

on the RF interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink byte/s LONG 4 1000 2

1 Downlink byte/s LONG 4 1000 2

Meas (9,9)-- mUTHBS-- Mean Meas Set: 0

Page 160: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 160/222

Name: user data throughput

(uplink/downlink) per cell

on the BSSGP Layer Gb

interface

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Mean user data throughput(LLC) Uplink for Interactive

services

byte/s LONG 4 1000 2

1

Mean user data throughput

(LLC) Uplink for Streaming

services

byte/s LONG 4 1000 2

2Mean user data throughput(LLC) Uplink for Background

services

byte/s LONG 4 1000 2

3

Mean user data throughput

(LLC) Downlink forInteractive services

byte/s LONG 4 1000 2

4

Mean user data throughput

(LLC) Downlink for

Streaming services

byte/s LONG 4 1000 2

5

Mean user data throughput

(LLC) Downlink forBackground services byte/s LONG 4 1000 2

Meas

Name:

(9,10)-- mSTHBS-- Mean

signalling data throughput

(uplink/downlink) per cell

on the BSSGP Layer Gb

interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink byte/s LONG 4 1000 21 Downlink byte/s LONG 4 1000 2

Meas

Name:

(9,11)-- nATPRRE-- Number

of Attempted packet resource

reassignments

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 161: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 161/222

0Number of attempted packetresource reassignments for an

Uplink TBF

N LONG 4 1 0

1

Number of attempted packet

resource reassignments for a

Downlink TBF

N LONG 4 1 0

Meas

Name:

(9,12)-- nSUPRRE-- Number

of Successful packet resource

reassignments

(uplink/downlink) per cell

Meas Set: 0

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy

0Number of successful packetresource reassignments for an

Uplink TBF

N LONG 4 1 0

1

Number of successful packet

resource reassignments for a

Downlink TBF

N LONG 4 1 0

Meas

Name:

(9,13)-- nACTTBF-- Total,

Mean number of active TBF

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Total number of active TBF

Uplink N LONG 4 1 0

1Mean number of active TBF

Uplink N LONG 4 1000 2

2Total number of active TBF

Downlink N LONG 4 1 0

3

Mean number of active TBF

Downlink  N LONG 4 1000 2

Meas

Name:

(9,13)-- nACTTBF-- Total,

Mean number of active

TBF (uplink/downlink) per

cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

4 Total number of active TBF N LONG 4 1 0

Page 162: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 162/222

uplink for InteractiveServices

5 Total number of active TBFuplink for Streaming Services

N LONG 4 1 0

6

Total number of active TBF

uplink for Background

Services

N LONG 4 1 0

7

Mean number of active TBF

uplink for Interactive

Services

N LONG 4 100000 4

8Mean number of active TBFuplink for Streaming Services

N LONG 4 100000 4

9Mean number of active TBFuplink for BackgroundServices

N LONG 4 100000 4

10

Total number of active TBF

downlink for Interactive

Services

N LONG 4 1 0

11

Total number of active TBF

downlink for Streaming

Services

N LONG 4 1 0

12

Total number of active TBF

downlink for BackgroundServices

N LONG 4 1 0

13

Mean number of active TBF

downlink for InteractiveServices

N LONG 4 100000 4

14

Mean number of active TBF

downlink for Streaming

Services

N LONG 4 100000 4

15

Mean number of active TBF

downlink for Background

Services

N LONG 4 100000 4

Meas

Name:

(9,13)-- nACTTBF-- Total,

Mean number of active

TBF (uplink/downlink) per

cell

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Total number of active TBF N LONG 4 1 0

Page 163: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 163/222

Uplink 

4

Total number of active TBF

uplink for InteractiveServices

N LONG 4 1 0

5Total number of active TBF

uplink for Streaming ServicesN LONG 4 1 0

6

Total number of active TBF

uplink for Background

Services

N LONG 4 1 0

16Mean number of active TBF

uplink N LONG 4 100000 4

7

Mean number of active TBF

uplink for InteractiveServices

N LONG 4 100000 4

8Mean number of active TBF

uplink for Streaming ServicesN LONG 4 100000 4

9Mean number of active TBFuplink for Background

Services

N LONG 4 100000 4

2Total number of active TBF

Downlink N LONG 4 1 0

10

Total number of active TBF

downlink for InteractiveServices

N LONG 4 1 0

11

Total number of active TBF

downlink for StreamingServices

N LONG 4 1 0

12

Total number of active TBF

downlink for Background

Services

N LONG 4 1 0

17Mean number of active TBF

downlink N LONG 4 100000 4

13

Mean number of active TBF

downlink for Interactive

Services

N LONG 4 100000 4

14

Mean number of active TBF

downlink for Streaming

Services

N LONG 4 100000 4

15

Mean number of active TBF

downlink for Background

Services

N LONG 4 100000 4

Page 164: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 164/222

 

MeasName:

(9,16)-- tANRGPRS--

Number of attempted GPRS

accesses per cell with no

GPRS radio resources

allocated

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of attempted GPRSaccesses per cell with no GPRS

radio resources allocated

N LONG 4 1 0

Meas

Name:

(9,18)-- rEMUTHRF--Retransmitted Mean user

data throughput

(uplink/downlink) per

coding scheme per cell on

the RF interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 CS-1 Uplink byte/s LONG 4 1000 2

1 CS-2 Uplink byte/s LONG 4 1000 2

2 CS-3 Uplink byte/s LONG 4 1000 23 CS-4 Uplink byte/s LONG 4 1000 2

4 MCS-1 Uplink byte/s LONG 4 1000 2

5 MCS-2 Uplink byte/s LONG 4 1000 2

6 MCS-3 Uplink byte/s LONG 4 1000 2

7 MCS-4 Uplink byte/s LONG 4 1000 2

8 MCS-5 Uplink byte/s LONG 4 1000 2

9 MCS-6 Uplink byte/s LONG 4 1000 2

10 MCS-7 Uplink byte/s LONG 4 1000 2

11 MCS-8 Uplink byte/s LONG 4 1000 2

12 MCS-9 Uplink byte/s LONG 4 1000 2

13 CS-1 Downlink byte/s LONG 4 1000 2

14 CS-2 Downlink byte/s LONG 4 1000 2

15 CS-3 Downlink byte/s LONG 4 1000 2

16 CS-4 Downlink byte/s LONG 4 1000 2

17 MCS-1 Downlink byte/s LONG 4 1000 2

Page 165: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 165/222

18 MCS-2 Downlink byte/s LONG 4 1000 2

19 MCS-3 Downlink byte/s LONG 4 1000 2

20 MCS-4 Downlink byte/s LONG 4 1000 2

21 MCS-5 Downlink byte/s LONG 4 1000 2

22 MCS-6 Downlink byte/s LONG 4 1000 2

23 MCS-7 Downlink byte/s LONG 4 1000 2

24 MCS-8 Downlink byte/s LONG 4 1000 2

25 MCS-9 Downlink byte/s LONG 4 1000 2

MeasName:

(9,19)-- nTRAPDU-- Number

of transmitted PDUs

(uplink/downlink) per codingscheme per cell on the RF

interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 CS-1 Uplink N LONG 4 1 0

1 CS-2 Uplink N LONG 4 1 0

2 CS-3 Uplink N LONG 4 1 0

3 CS-4 Uplink N LONG 4 1 0

4 MCS-1 Uplink N LONG 4 1 0

5 MCS-2 Uplink N LONG 4 1 0

6 MCS-3 Uplink N LONG 4 1 0

7 MCS-4 Uplink N LONG 4 1 0

8 MCS-5 Uplink N LONG 4 1 0

9 MCS-6 Uplink N LONG 4 1 0

10 MCS-7 Uplink N LONG 4 1 0

11 MCS-8 Uplink N LONG 4 1 0

12 MCS-9 Uplink N LONG 4 1 013 CS-1 Downlink N LONG 4 1 0

14 CS-2 Downlink N LONG 4 1 0

15 CS-3 Downlink N LONG 4 1 0

16 CS-4 Downlink N LONG 4 1 0

17 MCS-1 Downlink N LONG 4 1 0

18 MCS-2 Downlink N LONG 4 1 0

19 MCS-3 Downlink N LONG 4 1 0

Page 166: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 166/222

20 MCS-4 Downlink N LONG 4 1 0

21 MCS-5 Downlink N LONG 4 1 0

22 MCS-6 Downlink N LONG 4 1 0

23 MCS-7 Downlink N LONG 4 1 0

24 MCS-8 Downlink N LONG 4 1 0

25 MCS-9 Downlink N LONG 4 1 0

Meas

Name:

(9,20)-- lADAPTUD-- Link

adaptation measurements

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Link Adaptation upwards for

an Uplink TBFN LONG 4 1 0

1Link Adaptation downwards

for an Uplink TBFN LONG 4 1 0

2Link Adaptation upwards for a

Downlink TBFN LONG 4 1 0

3Link Adaptation downwards

for a Downlink TBFN LONG 4 1 0

Meas

Name:

(9,21)-- sERVUGDG--

Service upgrade/downgrade

measurements

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Service upgrade for an Uplink 

TBFN LONG 4 1 0

1Service downgrade for an

Uplink TBF

N LONG 4 1 0

2Service upgrade for aDownlink TBF

N LONG 4 1 0

3Service downgrade for a

Downlink TBFN LONG 4 1 0

Meas

Name:

(9,21)-- sERVUGDG--

Service upgrade/downgrade

measurements

(uplink/downlink) per cell

Meas Set: 1

Page 167: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 167/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Service upgrade for an Uplink TBF

N LONG 4 1 0

1Service downgrade for an

Uplink TBFN LONG 4 1 0

2Service upgrade for a

Downlink TBFN LONG 4 1 0

3Service downgrade for a

Downlink TBFN LONG 4 1 0

4PDSH pre-emption due tocircuit switched calls

N LONG 4 1 0

Meas

Name:

(9,22)-- nTRLLCFR--

Number of transmitted LLC

Frames (uplink/downlink)

per cell on the BSSGP Layer

Gb interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of transmitted LLCframes Uplink for Interactive

services

N LONG 4 1 0

1

Number of transmitted LLC

frames Uplink for Streaming

services

N LONG 4 1 0

2

Number of transmitted LLC

frames Uplink for Background

Services

N LONG 4 1 0

3Number of transmitted LLCframes Downlink forInteractive services

N LONG 4 1 0

4

Number of transmitted LLC

frames Downlink for Streaming

services

N LONG 4 1 0

5

Number of transmitted LLC

frames Downlink for

Background services

N LONG 4 1 0

Meas

Name:

(9,23)-- nDEFPDCH-- Min,

Max, Mean number of Meas Set: 0

Page 168: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 168/222

defined (configured) PDCH

per cell

CounterId

Name Unit Type Size Scale DigitAccuracy

0Minimum number of defined

PDCHN WORD 2 1 0

1Maximum number of defined

PDCHN WORD 2 1 0

2Mean number of definedPDCH

N LONG 4 1000 2

MeasName:

(9,24)-- nALIPDCH-- Min,

Max, Mean number of 

aligned PDCH per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Minimum number of aligned

PDCHN WORD 2 1 0

1Maximum number of aligned

PDCHN WORD 2 1 0

2Mean number of aligned

PDCH

N LONG 4 1000 2

Meas

Name:

(9,25)-- nALLPDCH-- Min,

Max, Mean number of used

(active TBF) PDCH

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Minimum number of used

(active TBF) PDCH Uplink N WORD 2 1 0

1 Maximum number of used(active TBF) PDCH Uplink 

N WORD 2 1 0

2Mean number of used (activeTBF) PDCH Uplink 

N LONG 4 1000 2

3Minimum number of used

(active TBF) PDCH Downlink N WORD 2 1 0

4Maximum number of used

(active TBF) PDCH Downlink N WORD 2 1 0

5 Mean number of used (active N LONG 4 1000 2

Page 169: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 169/222

TBF) PDCH Downlink 

Meas

Name:

(9,26)-- nTBFPDC-- Max,Mean number of TBF

allocated per PDCH

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Maximum number of TBF

allocated per PDCH Uplink N WORD 2 1 0

1Mean number of TBF

allocated per PDCH Uplink N LONG 4 1000 2

2Maximum number of TBFallocated per PDCH Downlink 

N WORD 2 1 0

3Mean number of TBF

allocated per PDCH Downlink N LONG 4 1000 2

Meas

Name:

(9,28)-- nTDMPAGC--

Number of transmitted and

discarded messages on the

PAGCH per cell

Meas Set: 0

Counter

Id Name Unit Type Size ScaleDigit

Accuracy

0

Number of transmitted

messages on the PAGCH forPS traffic

N LONG 4 1 0

1

Number of messages discarded

from the PAGCH queue for PS

traffic

N LONG 4 1 0

Meas

Name:

(9,29)-- sUCPDASA--

Number of successful PDCH

assignments

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Successful PDCH assignments

for an Uplink TBFN LONG 4 1 0

1Successful PDCH assignments

for a Downlink TBFN LONG 4 1 0

Page 170: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 170/222

Meas

Name:

(9,29)-- sUCPDASA--

Number of successful PDCH

assignments

(uplink/downlink) per cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

2Successful PDCH assignmentsfor an Uplink TBF for

Interactive services

N LONG 4 1 0

3

Successful PDCH assignments

for an Uplink TBF for

Streaming services

N LONG 4 1 0

4Successful PDCH assignmentsfor an Uplink TBF for

Background services

N LONG 4 1 0

5

Successful PDCH assignments

for an Downlink TBF forInteractive services

N LONG 4 1 0

6

Successful PDCH assignments

for an Downlink TBF for

Streaming services

N LONG 4 1 0

7

Successful PDCH assignments

for an Downlink TBF forBackground services N LONG 4 1 0

Meas

Name:

(9,30)-- uNSPDCSE--

Number of degraded PDCH

seizures (uplink/downlink)

per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of degraded PDCH

seizures for an Uplink TBF

N LONG 4 1 0

1Number of degraded PDCHseizures for a Downlink TBF

N LONG 4 1 0

Meas

Name:

(9,30)-- uNSPDCSE--

Number of degraded PDCH

seizures (uplink/downlink)

per cell

Meas Set: 1

Counter Name Unit Type Size Scale Digit

Page 171: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 171/222

Id Accuracy

2

Number of degraded PDCH

seizures due to not enoughAbis subchannels available for

an uplink TBF

N LONG 4 1 0

3

Number of degraded PDCH

seizures due to not enough

PDT at PCU available for a

new uplink TBF

N LONG 4 1 0

4

Number of degraded PDCHseizures due to not enoughradio resources available for a

new uplink TBF

N LONG 4 1 0

8

Number of degraded PDCH

seizures due to other cause for

an uplink TBF

N LONG 4 1 0

5

Number of degraded PDCH

seizures due to not enough

Abis subchannels available for

a downlink TBF

N LONG 4 1 0

6

Number of degraded PDCH

seizures due to not enough

PDT at PCU available for a

new downlink TBF

N LONG 4 1 0

7

Number of degraded PDCHseizures due to not enoughradio resources available for a

new downlink TBF

N LONG 4 1 0

9

Number of degraded PDCH

seizures due to other cause for

a downlink TBF

N LONG 4 1 0

Meas

Name:

(9,30)-- uNSPDCSE--

Number of degraded PDCH

seizures (uplink/downlink)

per cell

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

10

Number of degraded PDCH

seizures due to not enough

Abis subchannels available for

an uplink TBF for Interactive

N LONG 4 1 0

Page 172: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 172/222

services

11

Number of degraded PDCH

seizures due to not enoughAbis subchannels available for

an uplink TBF for Background

services

N LONG 4 1 0

12

Number of degraded PDCH

seizures due to not enough

PDT at PCU available for a

new uplink TBF for Interactive

services

N LONG 4 1 0

13

Number of degraded PDCH

seizures due to not enough

PDT at PCU available for a

new uplink TBF for

Background services

N LONG 4 1 0

14

Number of degraded PDCH

seizures due to not enoughradio resources available for a

new uplink TBF for Interactive

services

N LONG 4 1 0

15

Number of degraded PDCH

seizures due to not enough

radio resources available for anew uplink TBF for

Background services

N LONG 4 1 0

16

Number of degraded PDCH

seizures due to other cause foran uplink TBF for Interactive

services

N LONG 4 1 0

17

Number of degraded PDCH

seizures due to other cause for

an uplink TBF for Background

services

N LONG 4 1 0

18

Number of degraded PDCH

seizures due to not enough

Abis subchannels available for

a downlink TBF for Interactive

services

N LONG 4 1 0

19

Number of degraded PDCH

seizures due to not enoughAbis subchannels available for

a downlink TBF for

N LONG 4 1 0

Page 173: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 173/222

Background services

20

Number of degraded PDCH

seizures due to not enoughPDT at PCU available for a

new downlink TBF for

Interactive services

N LONG 4 1 0

21

Number of degraded PDCH

seizures due to not enough

PDT at PCU available for a

new downlink TBF for

Background services

N LONG 4 1 0

22

Number of degraded PDCH

seizures due to not enough

radio resources available for a

new downlink TBF for

Interactive services

N LONG 4 1 0

23

Number of degraded PDCH

seizures due to not enoughradio resources available for a

new downlink TBF for

Background services

N LONG 4 1 0

24

Number of degraded PDCH

seizures due to other cause for

a downlink TBF for Interactiveservices

N LONG 4 1 0

25

Number of degraded PDCHseizures due to other cause for

a downlink TBF forBackground services

N LONG 4 1 0

Meas

Name:

(9,31)-- sUCTETBF--

Number of successful

terminated TBF

(uplink/downlink) per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of successful

terminated TBF in RLC

acknowledged mode for an

Uplink TBF

N LONG 4 1 0

1Number of successfulterminated TBF in RLC

unacknowledged mode for an

N LONG 4 1 0

Page 174: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 174/222

Uplink TBF

2

Number of successful

terminated TBF in RLCacknowledged mode for a

Downlink TBF

N LONG 4 1 0

3

Number of successful

terminated TBF in RLC

unacknowledged mode for a

Downlink TBF

N LONG 4 1 0

Meas

Name:

(9,31)-- sUCTETBF--

Number of successful

terminated TBF(uplink/downlink) per cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

4

Number of successful

terminated TBF (uplink) for

Interactive services

N LONG 4 1 0

5

Number of successful

terminated TBF (uplink) for

Steraming services

N LONG 4 1 0

6Number of successfulterminated TBF (uplink) for

Background services

N LONG 4 1 0

7

Number of successful

terminated TBF (downlink) for

Interactive services

N LONG 4 1 0

8

Number of successful

terminated TBF (downlink) for

Steraming services

N LONG 4 1 0

9

Number of successful

terminated TBF (downlink) forBackground services

N LONG 4 1 0

Meas

Name:

(9,32)-- nRRFPDU-- Number

of Received FLUSH-PDU on

Gb per Cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of Received FLUSH- N LONG 4 1 0

Page 175: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 175/222

PDU on Gb per Cell

Meas

Name:

(9,32)-- nRRFPDU-- Numberof Received FLUSH-PDU on

Gb per Cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

1Number of Received FLUSH-PDU on Gb per Cell for

Intaractive services

N LONG 4 1 0

2

Number of Received FLUSH-

PDU on Gb per Cell for

Streaming services

N LONG 4 1 0

3

Number of Received FLUSH-

PDU on Gb per Cell for

Background services

N LONG 4 1 0

Meas

Name:

(9,33)-- uNSTETBF--

Number of unsuccessful

terminated TBF

(uplink/downlink) per cell

per cause

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Abnormal Release for an UL

TBF by expiry of T3169

(single mobile)

N LONG 4 1 0

1

Abnormal Release for a DL

TBF by expiry of T3195

(single mobile)

N LONG 4 1 0

2Complete preemption of ULTBF of priority level 1 (all

mobiles on a certain PDCH)

N LONG 4 1 0

3

Complete preemption of UL

TBF of priority level 2 (all

mobiles on a certain PDCH)

N LONG 4 1 0

4

Complete preemption of UL

TBF of priority level 3 (all

mobiles on a certain PDCH)

N LONG 4 1 0

5Complete preemption of ULTBF of priority level 4 (all

mobiles on a certain PDCH))

N LONG 4 1 0

Page 176: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 176/222

6Complete preemption of DLTBF of priority level 1 (all

mobiles on a certain PDCH)

N LONG 4 1 0

7

Complete preemption of DL

TBF of priority level 2 (all

mobiles on a certain PDCH)

N LONG 4 1 0

8

Complete preemption of DL

TBF of priority level 3 (all

mobiles on a certain PDCH)

N LONG 4 1 0

9Termination of UL TBF Gblink related component out of service

N LONG 4 1 0

10 Termination of DL TBF Gblink related component out of 

service

N LONG 4 1 0

11

Termination UL TBF in case

Abis/BTS component out of 

service

N LONG 4 1 0

12Termination DL TBF in caseAbis/BTS component out of 

service

N LONG 4 1 0

13

Number of UL TBFs

terminated when transmittingPacket Cell Change Order to

MS

N LONG 4 1 0

14

Number of DL TBFsterminated when transmitting

Packet Cell Change Order to

MS

N LONG 4 1 0

15

Number of UL TBFs

terminated due to reception of 

FLUSH_LL from SGSN

N LONG 4 1 0

16 Number of DL TBFsterminated due to reception of FLUSH_LL from SGSN

N LONG 4 1 0

Meas

Name:

(9,33)-- uNSTETBF--

Number of unsuccessful

terminated TBF

(uplink/downlink) per cell

per cause

Meas Set: 1

Counter Name Unit Type Size Scale Digit

Page 177: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 177/222

Id Accuracy

0

Abnormal Release for an UL

TBF by expiry of T3169(single mobile)

N LONG 4 1 0

1

Abnormal Release for a DL

TBF by expiry of T3195

(single mobile)

N LONG 4 1 0

17

Complete preemption of UL

TBF due to circuit switched

calls(all mobiles on a certainPDCH)

N LONG 4 1 0

18

Complete preemption of DL

TBF due to circuit switchedcalls(all mobiles on a certain

PDCH)

N LONG 4 1 0

9

Termination of UL TBF Gb

link related component out of 

service

N LONG 4 1 0

10Termination of DL TBF Gblink related component out of 

service

N LONG 4 1 0

11

Termination UL TBF in case

Abis/BTS component out of service N LONG 4 1 0

12

Termination DL TBF in case

Abis/BTS component out of service

N LONG 4 1 0

13

Number of UL TBFsterminated when transmitting

Packet Cell Change Order to

MS

N LONG 4 1 0

14

Number of DL TBFs

terminated when transmittingPacket Cell Change Order toMS

N LONG 4 1 0

15

Number of UL TBFs

terminated due to reception of 

FLUSH_LL from SGSN

N LONG 4 1 0

16

Number of DL TBFs

terminated due to reception of 

FLUSH_LL from SGSN

N LONG 4 1 0

19 Termination of UL TBF in case N LONG 4 1 0

Page 178: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 178/222

DTM establishing (set-up CS,when a MO PS session is

already active)

20

Termination of DL TBF in case

DTM establishing (set-up CS,

when a MT PS session is

already active)

N LONG 4 1 0

21

Termination of UL TBF in case

of handover when a DTM is

established

N LONG 4 1 0

22Termination of DL TBF in caseof handover when a DTM is

established

N LONG 4 1 0

Meas

Name:

(9,33)-- uNSTETBF--

Number of unsuccessful

terminated TBF

(uplink/downlink) per cell

per cause

Meas Set: 2

Counter

IdName Unit Type Size Scale

Digit

Accuracy

23

Abnormal Release for an UL

TBF by expiry of T3169 for

Interactive services

N LONG 4 1 0

24

Abnormal Release for an UL

TBF by expiry of T3169 for

Streaming services

N LONG 4 1 0

25

Abnormal Release for an UL

TBF by expiry of T3169 forBackground services

N LONG 4 1 0

26Abnormal Release for an DLTBF by expiry of T3195 for

Interactive services

N LONG 4 1 0

27

Abnormal Release for an DL

TBF by expiry of T3195 for

Streaming services

N LONG 4 1 0

28

Abnormal Release for an DL

TBF by expiry of T3195 forBackground services

N LONG 4 1 0

29

Complete preemption of UL

TBF due to circuit switched

calls for Interactive services

N LONG 4 1 0

Page 179: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 179/222

30Complete preemption of ULTBF due to circuit switched

calls for Streaming services

N LONG 4 1 0

31

Complete preemption of UL

TBF due to circuit switched

calls for Background services

N LONG 4 1 0

32

Complete preemption of DL

TBF due to circuit switched

calls for Interactive services

N LONG 4 1 0

33Complete preemption of DLTBF due to circuit switchedcalls for Streaming services

N LONG 4 1 0

34 Complete preemption of DLTBF due to circuit switched

calls for Background services

N LONG 4 1 0

35

Termination of UL TBF Gb

link related component out of 

service for Interactive services

N LONG 4 1 0

36Termination of UL TBF Gblink related component out of 

service for Streaming services

N LONG 4 1 0

37

Termination of UL TBF Gb

link related component out of service for Background

services

N LONG 4 1 0

38Termination of DL TBF Gblink related component out of 

service for Interactive services

N LONG 4 1 0

39

Termination of DL TBF Gb

link related component out of 

service for Streaming services

N LONG 4 1 0

40

Termination of DL TBF Gb

link related component out of service for Backgroundservices

N LONG 4 1 0

41

Termination UL TBF in case

Abis/BTS component out of 

service for Interactive services

N LONG 4 1 0

42

Termination UL TBF in case

Abis/BTS component out of 

service for Streaming services

N LONG 4 1 0

43 Termination UL TBF in case N LONG 4 1 0

Page 180: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 180/222

Abis/BTS component out of service for Background

services

44

Termination DL TBF in case

Abis/BTS component out of 

service for Interactive services

N LONG 4 1 0

45

Termination DL TBF in case

Abis/BTS component out of 

service for Streaming services

N LONG 4 1 0

46

Termination DL TBF in caseAbis/BTS component out of service for Background

services

N LONG 4 1 0

47

Number of UL TBFs

terminated when transmitting

Packet Cell Change Order toMS for Interactive services

N LONG 4 1 0

48

Number of UL TBFs

terminated when transmitting

Packet Cell Change Order to

MS for Streaming services

N LONG 4 1 0

49

Number of UL TBFs

terminated when transmitting

Packet Cell Change Order toMS for Background services

N LONG 4 1 0

50

Number of DL TBFsterminated when transmitting

Packet Cell Change Order to

MS for Interactive services

N LONG 4 1 0

51

Number of DL TBFs

terminated when transmittingPacket Cell Change Order to

MS for Streaming services

N LONG 4 1 0

52

Number of DL TBFsterminated when transmitting

Packet Cell Change Order toMS for Background services

N LONG 4 1 0

53

Number of UL TBFs

terminated due to reception of 

FLUSH_LL from SGSN for

Interactive services

N LONG 4 1 0

54Number of UL TBFs

terminated due to reception of N LONG 4 1 0

Page 181: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 181/222

FLUSH_LL from SGSN forStreaming services

55Number of UL TBFsterminated due to reception of 

FLUSH_LL from SGSN for

Background services

N LONG 4 1 0

56

Number of DL TBFs

terminated due to reception of 

FLUSH_LL from SGSN for

Interactive services

N LONG 4 1 0

57

Number of DL TBFsterminated due to reception of 

FLUSH_LL from SGSN for

Streaming services

N LONG 4 1 0

58

Number of DL TBFs

terminated due to reception of FLUSH_LL from SGSN for

Background services

N LONG 4 1 0

59

Termination of UL TBF in case

DTM establishing (set-up CS,

when a MO PS session isalready active)for Interactive

services

N LONG 4 1 0

60

Termination of UL TBF in caseDTM establishing (set-up CS,

when a MO PS session isalready active)for Stremaing

services

N LONG 4 1 0

61

Termination of UL TBF in case

DTM establishing (set-up CS,

when a MO PS session is

already active)for Background

services

N LONG 4 1 0

62

Termination of DL TBF in caseDTM establishing (set-up CS,

when a MO PS session is

already active)for Interactive

services

N LONG 4 1 0

63

Termination of DL TBF in case

DTM establishing (set-up CS,

when a MO PS session isalready active)for Stremaing

services

N LONG 4 1 0

Page 182: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 182/222

64

Termination of DL TBF in caseDTM establishing (set-up CS,

when a MO PS session is

already active)for Background

services

N LONG 4 1 0

65

Termination of UL TBF in case

of handover when a DTM isestablished for Interactive

services

N LONG 4 1 0

66

Termination of UL TBF in case

of handover when a DTM isestablished for Streamingservices

N LONG 4 1 0

67

Termination of UL TBF in case

of handover when a DTM is

established for Background

services

N LONG 4 1 0

68

Termination of DL TBF in caseof handover when a DTM is

established for Interactive

services

N LONG 4 1 0

69

Termination of DL TBF in case

of handover when a DTM is

established for Streamingservices

N LONG 4 1 0

70

Termination of DL TBF in caseof handover when a DTM is

established for Backgroundservices

N LONG 4 1 0

71Other causes for Interactive

servicesN LONG 4 1 0

72Other causes for Streaming

servicesN LONG 4 1 0

73 Other causes for Backgroundservices

N LONG 4 1 0

Meas

Name:

(9,35)-- dISCLPDU-- Number

of discarded LLC PDU per

cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of discarded first DL N LONG 4 1 0

Page 183: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 183/222

LLC PDU due to pdu lifetimefor Interactive services

1Number of discarded first DLLLC PDUs due lack of radio

resources for Interactive

services

N LONG 4 1 0

2

Number of discarded first DL

LLC PDUs due to no answer

from MS for Interactive

services

N LONG 4 1 0

3Number of discarded DL LLCPDUs due to preemption for

Interactive services

N LONG 4 1 0

4

Number of discarded DL LLC

PDUs due to loss of contact

with MS for Interactiveservices

N LONG 4 1 0

5

Number of discarded DL LLC

PDUs due to bad radio link 

quality for Interactive services

N LONG 4 1 0

6

Number of discarded DL LLC

PDU due to NCCR and no

FLUSH-LL arrived for

Interactive services

N LONG 4 1 0

7

Number of discarded DL LLCPDUs due to MS initiated cellreselection for Interactive

services

N LONG 4 1 0

8

Number of discarded DL LLC

PDUs due to Network 

Controlled Cell Reselection forInteractive services

N LONG 4 1 0

9

Number of discarded DL LLC

PDUs due to life timeexpiration for Interactive

services

N LONG 4 1 0

10

Number of discarded UL LLC

PDUs due to Gb link 

congestion for Interactive

services

N LONG 4 1 0

11Number of discarded UL LLCPDUs due to Gb link failure for

Interactive services

N LONG 4 1 0

Page 184: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 184/222

12

Number of discarded UL LLCPDUs due Abis/BTS

component out of service for

Interactive services

N LONG 4 1 0

13

Number of discarded DL LLC

PDUs due Abis/BTS

component out of service forInteractive services

N LONG 4 1 0

14

Number of discarded first DL

LLC PDU due to pdu lifetime

for Streaming services

N LONG 4 1 0

15

Number of discarded first DL

LLC PDUs due lack of radio

resources for Streaming

services

N LONG 4 1 0

16

Number of discarded first DLLLC PDUs due to no answer

from MS for Streamingservices

N LONG 4 1 0

17

Number of discarded DL LLC

PDUs due to preemption forStreaming services

N LONG 4 1 0

18

Number of discarded DL LLC

PDUs due to loss of contactwith MS for Streaming services

N LONG 4 1 0

19Number of discarded DL LLCPDUs due to bad radio link 

quality for Streaming services

N LONG 4 1 0

20

Number of discarded DL LLC

PDU due to NCCR and no

FLUSH-LL arrived forStreaming services

N LONG 4 1 0

21

Number of discarded DL LLC

PDUs due to MS initiated cellreselection for Streaming

services

N LONG 4 1 0

22

Number of discarded DL LLC

PDUs due to Network 

Controlled Cell Reselection for

Streaming services

N LONG 4 1 0

23Number of discarded DL LLCPDUs due to life time

expiration for Streaming

N LONG 4 1 0

Page 185: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 185/222

services

24

Number of discarded UL LLC

PDUs due to Gb link congestion for Streaming

services

N LONG 4 1 0

25

Number of discarded UL LLC

PDUs due to Gb link failure for

Streaming services

N LONG 4 1 0

26

Number of discarded UL LLC

PDUs due Abis/BTScomponent out of service forStreaming services

N LONG 4 1 0

27Number of discarded DL LLCPDUs due Abis/BTS

component out of service for

Streaming services

N LONG 4 1 0

28

Number of discarded first DL

LLC PDU due to pdu lifetime

for Background services

N LONG 4 1 0

29

Number of discarded first DL

LLC PDUs due lack of radio

resources for Background

services

N LONG 4 1 0

30

Number of discarded first DL

LLC PDUs due to no answerfrom MS for Backgroundservices

N LONG 4 1 0

31

Number of discarded DL LLC

PDUs due to preemption for

Streaming services

N LONG 4 1 0

32

Number of discarded DL LLC

PDUs due to loss of contact

with MS for Background

services

N LONG 4 1 0

33

Number of discarded DL LLC

PDUs due to bad radio link 

quality for Background

services

N LONG 4 1 0

34

Number of discarded DL LLCPDU due to NCCR and no

FLUSH-LL arrived forBackground services

N LONG 4 1 0

Page 186: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 186/222

35

Number of discarded DL LLCPDUs due to MS initiated cell

reselection for Background

services

N LONG 4 1 0

36

Number of discarded DL LLC

PDUs due to Network 

Controlled Cell Reselection forBackground services

N LONG 4 1 0

37

Number of discarded DL LLC

PDUs due to life time

expiration for Backgroundservices

N LONG 4 1 0

38

Number of discarded UL LLC

PDUs due to Gb link 

congestion for Background

services

N LONG 4 1 0

39

Number of discarded UL LLC

PDUs due to Gb link failure forBackground services

N LONG 4 1 0

40

Number of discarded UL LLC

PDUs due Abis/BTScomponent out of service for

Background services

N LONG 4 1 0

41

Number of discarded DL LLCPDUs due Abis/BTS

component out of service forBackground services

N LONG 4 1 0

Meas

Name:

(9,35)-- dISCLPDU-- Number

of discarded LLC PDU per

cell

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Number of discarded first DL

LLC PDU due to pdu lifetimefor Interactive services

N LONG 4 1 0

1

Number of discarded first DL

LLC PDUs due lack of radio

resources for Interactive

services

N LONG 4 1 0

2Number of discarded first DL

LLC PDUs due to no answerN LONG 4 1 0

Page 187: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 187/222

from MS for Interactiveservices

3Number of discarded DL LLCPDUs due to preemption for

Interactive services

N LONG 4 1 0

4

Number of discarded DL LLC

PDUs due to loss of contact

with MS for Interactive

services

N LONG 4 1 0

5Number of discarded DL LLCPDUs due to bad radio link quality for Interactive services

N LONG 4 1 0

6Number of discarded DL LLCPDU due to NCCR and no

FLUSH-LL arrived for

Interactive services

N LONG 4 1 0

7

Number of discarded DL LLC

PDUs due to MS initiated cell

reselection for Interactive

services

N LONG 4 1 0

8

Number of discarded DL LLC

PDUs due to Network 

Controlled Cell Reselection for

Interactive services

N LONG 4 1 0

9

Number of discarded DL LLCPDUs due to life timeexpiration for Interactive

services

N LONG 4 1 0

11

Number of discarded UL LLC

PDUs due to Gb link failure for

Interactive services

N LONG 4 1 0

12

Number of discarded UL LLC

PDUs due Abis/BTS

component out of service forInteractive services

N LONG 4 1 0

13

Number of discarded DL LLC

PDUs due Abis/BTS

component out of service for

Interactive services

N LONG 4 1 0

14

Number of discarded first DL

LLC PDU due to pdu lifetimefor Streaming services

N LONG 4 1 0

Page 188: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 188/222

15

Number of discarded first DLLLC PDUs due lack of radio

resources for Streaming

services

N LONG 4 1 0

16

Number of discarded first DL

LLC PDUs due to no answer

from MS for Streamingservices

N LONG 4 1 0

17

Number of discarded DL LLC

PDUs due to preemption for

Streaming services

N LONG 4 1 0

18

Number of discarded DL LLC

PDUs due to loss of contact

with MS for Streaming services

N LONG 4 1 0

19

Number of discarded DL LLC

PDUs due to bad radio link quality for Streaming services

N LONG 4 1 0

20

Number of discarded DL LLC

PDU due to NCCR and no

FLUSH-LL arrived for

Streaming services

N LONG 4 1 0

21

Number of discarded DL LLC

PDUs due to MS initiated cell

reselection for Streamingservices

N LONG 4 1 0

22

Number of discarded DL LLCPDUs due to Network 

Controlled Cell Reselection for

Streaming services

N LONG 4 1 0

23

Number of discarded DL LLC

PDUs due to life timeexpiration for Streaming

services

N LONG 4 1 0

25Number of discarded UL LLCPDUs due to Gb link failure for

Streaming services

N LONG 4 1 0

26

Number of discarded UL LLC

PDUs due Abis/BTS

component out of service for

Streaming services

N LONG 4 1 0

27Number of discarded DL LLCPDUs due Abis/BTS

component out of service for

N LONG 4 1 0

Page 189: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 189/222

Streaming services

28

Number of discarded first DL

LLC PDU due to pdu lifetimefor Background services

N LONG 4 1 0

29

Number of discarded first DL

LLC PDUs due lack of radio

resources for Background

services

N LONG 4 1 0

30

Number of discarded first DL

LLC PDUs due to no answerfrom MS for Backgroundservices

N LONG 4 1 0

31 Number of discarded DL LLCPDUs due to preemption for

Streaming services

N LONG 4 1 0

32

Number of discarded DL LLC

PDUs due to loss of contact

with MS for Background

services

N LONG 4 1 0

33

Number of discarded DL LLC

PDUs due to bad radio link 

quality for Background

services

N LONG 4 1 0

34

Number of discarded DL LLC

PDU due to NCCR and noFLUSH-LL arrived forBackground services

N LONG 4 1 0

35

Number of discarded DL LLC

PDUs due to MS initiated cell

reselection for Background

services

N LONG 4 1 0

36

Number of discarded DL LLC

PDUs due to Network 

Controlled Cell Reselection forBackground services

N LONG 4 1 0

37

Number of discarded DL LLC

PDUs due to life time

expiration for Background

services

N LONG 4 1 0

39

Number of discarded UL LLC

PDUs due to Gb link failure forBackground services

N LONG 4 1 0

Page 190: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 190/222

40

Number of discarded UL LLCPDUs due Abis/BTS

component out of service for

Background services

N LONG 4 1 0

41

Number of discarded DL LLC

PDUs due Abis/BTS

component out of service forBackground services

N LONG 4 1 0

Meas

Name:

(9,36)-- aTCRORIG-- Cell

reselection: AttemptsMeas Set: 0

Counter

Id

Name Unit Type Size ScaleDigit

Accuracy

0Number of attempted intraBSC network controlled cell

reselection to a GSM target cell

N LONG 4 1 0

1

Number of attempted inter

BSC network controlled cell

reselection to a GSM target cell

N LONG 4 1 0

2

Number of attempted network 

controlled cell reselection to a

UMTS target cell

N LONG 4 1 0

3 Number of attempted network assisted cell reselection

N LONG 4 1 0

4

Number of attempted network 

assisted cell reselection where

the BSC sends assistance data

of internal (same BSC)

adjacent cell to the MS

N LONG 4 1 0

5

Number of attempted network 

assisted cell reselection wherethe BSC sends assistance data

of external (different BSC)

adjacent cell to the MS

N LONG 4 1 0

6

Number of attempted network 

assisted cell reselection where

the BSC accepts the internal

proposed GSM target cell

N LONG 4 1 0

7

Number of attempted network 

assisted cell reselection where

the BSC accepts the external

proposed GSM target cell

N LONG 4 1 0

Page 191: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 191/222

8

Number of attempted network assisted cell reselection where

the BSC selects an internal

GSM target cell which is

different from the proposed cell

N LONG 4 1 0

9

Number of attempted network 

assisted cell reselection wherethe BSC selects an external

GSM target cell which is

different from the proposed cell

N LONG 4 1 0

Meas

Name:

(9,37)-- sUCRORIG-- Cell

reselection: Successful

procedure

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Successful internal network 

controlled cell reselectionN LONG 4 1 0

1Successful internal NACC due

to packet cell change continueN LONG 4 1 0

2Successful internal NACC due

to packet cell change orderN LONG 4 1 0

Meas

Name:

(9,38)-- uNCRORIG-- Cell

reselection: Unsuccessful

procedure

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Frequency not implemented in

case the intended target cell is

of type GSM and is served by

the same BSC (intra system,

intra BSC)

N LONG 4 1 0

1

No response on target cell in

case the intended target cell is

of type GSM and is served bythe same BSC (intra system,

intra BSC)

N LONG 4 1 0

2

Immediate Assignment Reject

or Packet Access Reject on

target cell in case the intended

target cell is of type GSM and

N LONG 4 1 0

Page 192: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 192/222

is served by the same BSC(intra system, intra BSC)

3

Ongoing CS connection in casethe intended target cell is of 

type GSM and is served by the

same BSC (intra system, intra

BSC)

N LONG 4 1 0

4

MS in GMM standby state in

case the intended target cell is

of type GSM and is served by

the same BSC (intra system,intra BSC)

N LONG 4 1 0

5

Forced to the standby state in

case the intended target cell is

of type GSM and is served by

the same BSC (intra system,

intra BSC)

N LONG 4 1 0

6

Frequency not implemented incase the intended target cell is

of type GSM and is served by a

different BSC (intra system,

inter BSC)

N LONG 4 1 0

7

No response on target cell in

case the intended target cell isof type GSM and is served by a

different BSC (intra system,inter BSC)

N LONG 4 1 0

8

Immediate Assignment Rejector Packet Access Reject on

target cell in case the intended

target cell is of type GSM and

is served by a different BSC

(intra system, inter BSC)

N LONG 4 1 0

9

Ongoing CS connection in casethe intended target cell is of 

type GSM and is served by a

different BSC (intra system,

inter BSC)

N LONG 4 1 0

10

MS in GMM standby state incase the intended target cell is

of type GSM and is served by adifferent BSC (intra system,

inter BSC)

N LONG 4 1 0

Page 193: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 193/222

11

Forced to the standby state incase the intended target cell is

of type GSM and is served by a

different BSC (intra system,

inter BSC)

N LONG 4 1 0

12

Frequency not implemented in

case the intended target cell isof type UMTS (inter system)

N LONG 4 1 0

13

No response on target cell in

case the intended target cell is

of type UMTS (inter system)

N LONG 4 1 0

14

Immediate Assignment Reject

or Packet Access Reject on

target cell in case the intended

target cell is of type UMTS

(inter system)

N LONG 4 1 0

15

Ongoing CS connection in case

the intended target cell is of type UMTS (inter system)

N LONG 4 1 0

16

MS in GMM standby state in

case the intended target cell isof type UMTS (inter system)

N LONG 4 1 0

17

Forced to the standby state in

case the intended target cell isof type UMTS (inter system)

N LONG 4 1 0

Meas

Name:

(9,39)-- lLCQULEV-- Filling

level of the DL LLC PDU

queues

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Cell related: Filling level is less

than 20% of maximum buffer

size

N LONG 4 1 0

1

Cell related: Filling level is

between 20% and 40% of 

maximum buffer size

N LONG 4 1 0

2Cell related: Filling level isbetween 40% and 60% of 

maximum buffer size

N LONG 4 1 0

3Cell related: Filling level is

between 60% and 80% of N LONG 4 1 0

Page 194: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 194/222

maximum buffer size

4

Cell related: Filling level is

between 80% and 100% of maximum buffer size

N LONG 4 1 0

5

Cell related: Filling level is

between 100% and 120% of 

maximum buffer size

N LONG 4 1 0

6

Cell related: Filling level is

between 120% and 140% of 

maximum buffer size

N LONG 4 1 0

7Cell related: Filling level ismore than 140% of maximum

buffer size

N LONG 4 1 0

8MS related: Filling level is lessthan 20% of maximum buffer

size

N LONG 4 1 0

9

MS related: Filling level is

between 20% and 40% of maximum buffer size

N LONG 4 1 0

10

MS related: Filling level is

between 40% and 60% of 

maximum buffer size

N LONG 4 1 0

11MS related: Filling level isbetween 60% and 80% of 

maximum buffer size

N LONG 4 1 0

12MS related: Filling level isbetween 80% and 100% of 

maximum buffer size

N LONG 4 1 0

13

MS related: Filling level is

between 100% and 120% of 

maximum buffer size

N LONG 4 1 0

14

MS related: Filling level is

between 120% and 140% of maximum buffer size

N LONG 4 1 0

15

MS related: Filling level is

more than 140% of maximum

buffer size

N LONG 4 1 0

16

PFC related - Interactive

services: Filling level is less

than 20% of maximum buffer

size

N LONG 4 1 0

17 PFC related - Interactive N LONG 4 1 0

Page 195: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 195/222

services: Filling level isbetween 20% and 40% of 

maximum buffer size

18

PFC related - Interactive

services: Filling level is

between 40% and 60% of 

maximum buffer size

N LONG 4 1 0

19

PFC related - Interactive

services: Filling level is

between 60% and 80% of 

maximum buffer size

N LONG 4 1 0

20

PFC related - Interactive

services: Filling level is

between 80% and 100% of 

maximum buffer size

N LONG 4 1 0

21

PFC related - Interactiveservices: Filling level is

between 100% and 120% of maximum buffer size

N LONG 4 1 0

22

PFC related - Interactive

services: Filling level isbetween 120% and 140% of 

maximum buffer size

N LONG 4 1 0

23

PFC related - Interactiveservices: Filling level is more

than 140% of maximum buffersize

N LONG 4 1 0

24

PFC related - Streaming

services: Filling level is less

than 20% of maximum buffer

size

N LONG 4 1 0

25

PFC related - Streaming

services: Filling level is

between 20% and 40% of maximum buffer size

N LONG 4 1 0

26

PFC related - Streamingservices: Filling level is

between 40% and 60% of 

maximum buffer size

N LONG 4 1 0

27

PFC related - Streaming

services: Filling level isbetween 60% and 80% of 

maximum buffer size

N LONG 4 1 0

Page 196: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 196/222

28

PFC related - Streamingservices: Filling level is

between 80% and 100% of 

maximum buffer size

N LONG 4 1 0

29

PFC related - Streaming

services: Filling level is

between 100% and 120% of maximum buffer size

N LONG 4 1 0

30

PFC related - Streaming

services: Filling level is

between 120% and 140% of maximum buffer size

N LONG 4 1 0

31

PFC related - Streaming

services: Filling level is more

than 140% of maximum buffer

size

N LONG 4 1 0

32

PFC related - Background

services: Filling level is lessthan 20% of maximum buffer

size

N LONG 4 1 0

33

PFC related - Backgroundservices: Filling level is

between 20% and 40% of 

maximum buffer size

N LONG 4 1 0

34

PFC related - Background

services: Filling level isbetween 40% and 60% of 

maximum buffer size

N LONG 4 1 0

35

PFC related - Background

services: Filling level is

between 60% and 80% of 

maximum buffer size

N LONG 4 1 0

36

PFC related - Background

services: Filling level isbetween 80% and 100% of 

maximum buffer size

N LONG 4 1 0

37

PFC related - Background

services: Filling level is

between 100% and 120% of 

maximum buffer size

N LONG 4 1 0

38PFC related - Backgroundservices: Filling level is

between 120% and 140% of 

N LONG 4 1 0

Page 197: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 197/222

maximum buffer size

39

PFC related - Background

services: Filling level is morethan 140% of maximum buffer

size

N LONG 4 1 0

Meas

Name:

(9,40)-- nDEFPCCC-- Mean

Number of all Defined

PCCCH channels

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink N LONG 4 1000 2

1 Downlink N LONG 4 1000 2

Meas

Name:

(9,41)-- nSAPRACH--

Number of Successful

Accesses to PRACH channel

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Successful

Accesses to PRACH channelN LONG 4 1 0

1 Number of invalid accesses toPRACH with signal level too

weak 

N LONG 4 1 0

2

Number of invalid accesses to

PRACH with excessive

distance

N LONG 4 1 0

3Number of invalid accesses toPRACH with other causes

N LONG 4 1 0

Meas

Name:

(9,42)-- wUTHBS--

Weighted user datathroughput

(uplink/downlink) per

Traffic Class per cell on

the BSSGP Layer Gb

Interface

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Weighted user data

throughput (LLC) Uplink Kbyte/s LONG 4 1000 2

Page 198: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 198/222

for Interactive services

1

Weighted user data

throughput (LLC) Uplink for Streaming services

Kbyte/s LONG 4 1000 2

2

Weighted user data

throughput (LLC) Uplink 

for Background services

Kbyte/s LONG 4 1000 2

3

Weighted user data

throughput (LLC) Downlink 

for Interactive services

Kbyte/s LONG 4 1000 2

4Weighted user datathroughput (LLC) Downlink 

for Streaming services

Kbyte/s LONG 4 1000 2

5Weighted user datathroughput (LLC) Downlink 

for Background services

Kbyte/s LONG 4 1000 2

Meas

Name:

(9,43)-- mUTLLC-- LLC

user data measurements

(uplink/downlink) per

Traffic Class per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Weighted LLC Data

Throughput, UL, GPRS,

Streaming

Kbyte/s LONG 4 1000 2

1

Weighted LLC Data

Throughput, UL, GPRS,

Interactive1

Kbyte/s LONG 4 1000 2

2

Weighted LLC Data

Throughput, UL, GPRS,Interactive2

Kbyte/s LONG 4 1000 2

3Weighted LLC DataThroughput, UL, GPRS,

Interactive3

Kbyte/s LONG 4 1000 2

4Weighted LLC DataThroughput, UL, GPRS,

Background

Kbyte/s LONG 4 1000 2

5

Weighted LLC Data

Throughput, UL, EDGE,

Streaming

Kbyte/s LONG 4 1000 2

Page 199: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 199/222

6Weighted LLC DataThroughput, UL, EDGE,

Interactive1

Kbyte/s LONG 4 1000 2

7

Weighted LLC Data

Throughput, UL, EDGE,

Interactive2

Kbyte/s LONG 4 1000 2

8

Weighted LLC Data

Throughput, UL, EDGE,

Interactive3

Kbyte/s LONG 4 1000 2

9Weighted LLC DataThroughput, UL, EDGE,Background

Kbyte/s LONG 4 1000 2

10 Weighted LLC DataThroughput, DL, GPRS,

Streaming

Kbyte/s LONG 4 1000 2

11

Weighted LLC Data

Throughput, DL, GPRS,

Interactive1

Kbyte/s LONG 4 1000 2

12Weighted LLC DataThroughput, DL, GPRS,

Interactive2

Kbyte/s LONG 4 1000 2

13

Weighted LLC Data

Throughput, DL, GPRS,Interactive3 Kbyte/s LONG 4 1000 2

14

Weighted LLC Data

Throughput, DL, GPRS,Background

Kbyte/s LONG 4 1000 2

15Weighted LLC DataThroughput, DL, EDGE,

Streaming

Kbyte/s LONG 4 1000 2

16

Weighted LLC Data

Throughput, DL, EDGE,

Interactive1

Kbyte/s LONG 4 1000 2

17

Weighted LLC Data

Throughput, DL, EDGE,

Interactive2

Kbyte/s LONG 4 1000 2

18Weighted LLC DataThroughput, DL, EDGE,

Interactive3

Kbyte/s LONG 4 1000 2

19

Weighted LLC Data

Throughput, DL, EDGE,Background

Kbyte/s LONG 4 1000 2

Page 200: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 200/222

20LLC Data Throughput perSingle Timeslot, UL,

GPRS, Streaming

Kbyte/s LONG 4 1000 2

21

LLC Data Throughput per

Single Timeslot, UL,

GPRS, Interactive1

Kbyte/s LONG 4 1000 2

22

LLC Data Throughput per

Single Timeslot, UL,

GPRS, Interactive2

Kbyte/s LONG 4 1000 2

23LLC Data Throughput perSingle Timeslot, UL,GPRS, Interactive3

Kbyte/s LONG 4 1000 2

24 LLC Data Throughput perSingle Timeslot, UL,

GPRS, Background

Kbyte/s LONG 4 1000 2

25

LLC Data Throughput per

Single Timeslot, UL,

EDGE, Streaming

Kbyte/s LONG 4 1000 2

26LLC Data Throughput perSingle Timeslot, UL,

EDGE, Interactive1

Kbyte/s LONG 4 1000 2

27

LLC Data Throughput per

Single Timeslot, UL,EDGE, Interactive2 Kbyte/s LONG 4 1000 2

28

LLC Data Throughput per

Single Timeslot, UL,EDGE, Interactive3

Kbyte/s LONG 4 1000 2

29LLC Data Throughput perSingle Timeslot, UL,

EDGE, Background

Kbyte/s LONG 4 1000 2

30

LLC Data Throughput per

Single Timeslot, DL,

GPRS, Streaming

Kbyte/s LONG 4 1000 2

31

LLC Data Throughput per

Single Timeslot, DL,

GPRS, Interactive1

Kbyte/s LONG 4 1000 2

32LLC Data Throughput perSingle Timeslot, DL,

GPRS, Interactive2

Kbyte/s LONG 4 1000 2

33

LLC Data Throughput per

Single Timeslot, DL,GPRS, Interactive3

Kbyte/s LONG 4 1000 2

Page 201: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 201/222

34LLC Data Throughput perSingle Timeslot, DL,

GPRS, Background

Kbyte/s LONG 4 1000 2

35

LLC Data Throughput per

Single Timeslot, DL,

EDGE, Streaming

Kbyte/s LONG 4 1000 2

36

LLC Data Throughput per

Single Timeslot, DL,

EDGE, Interactive1

Kbyte/s LONG 4 1000 2

37LLC Data Throughput perSingle Timeslot, DL,EDGE, Interactive2

Kbyte/s LONG 4 1000 2

38 LLC Data Throughput perSingle Timeslot, DL,

EDGE, Interactive3

Kbyte/s LONG 4 1000 2

39

LLC Data Throughput per

Single Timeslot, DL,

EDGE, Background

Kbyte/s LONG 4 1000 2

40Percent Timeslot ResourcesAchieved, UL, GPRS,

Streaming

% WORD 2 100 2

41

Percent Timeslot Resources

Achieved, UL, GPRS,Interactive1 % WORD 2 100 2

42

Percent Timeslot Resources

Achieved, UL, GPRS,Interactive2

% WORD 2 100 2

43Percent Timeslot ResourcesAchieved, UL, GPRS,

Interactive3

% WORD 2 100 2

44

Percent Timeslot Resources

Achieved, UL, GPRS,

Background

% WORD 2 100 2

45

Percent Timeslot Resources

Achieved, UL, EDGE,

Streaming

% WORD 2 100 2

46Percent Timeslot ResourcesAchieved, UL, EDGE,

Interactive1

% WORD 2 100 2

47

Percent Timeslot Resources

Achieved, UL, EDGE,Interactive2

% WORD 2 100 2

Page 202: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 202/222

48Percent Timeslot ResourcesAchieved, UL, EDGE,

Interactive3

% WORD 2 100 2

49

Percent Timeslot Resources

Achieved, UL, EDGE,

Background

% WORD 2 100 2

50

Percent Timeslot Resources

Achieved, DL, GPRS,

Streaming

% WORD 2 100 2

51Percent Timeslot ResourcesAchieved, DL, GPRS,Interactive1

% WORD 2 100 2

52 Percent Timeslot ResourcesAchieved, DL, GPRS,

Interactive2

% WORD 2 100 2

53

Percent Timeslot Resources

Achieved, DL, GPRS,

Interactive3

% WORD 2 100 2

54Percent Timeslot ResourcesAchieved, DL, GPRS,

Background

% WORD 2 100 2

55

Percent Timeslot Resources

Achieved, DL, EDGE,Streaming % WORD 2 100 2

56

Percent Timeslot Resources

Achieved, DL, EDGE,Interactive1

% WORD 2 100 2

57Percent Timeslot ResourcesAchieved, DL, EDGE,

Interactive2

% WORD 2 100 2

58

Percent Timeslot Resources

Achieved, DL, EDGE,

Interactive3

% WORD 2 100 2

59

Percent Timeslot Resources

Achieved, DL, EDGE,

Background

% WORD 2 100 2

60LLC Data Volume, UL,GPRS, Streaming

Kbyte LONG 4 1000 2

61LLC Data Volume, UL,

GPRS, Interactive1Kbyte LONG 4 1000 2

62LLC Data Volume, UL,GPRS, Interactive2

Kbyte LONG 4 1000 2

Page 203: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 203/222

63LLC Data Volume, UL,GPRS, Interactive3

Kbyte LONG 4 1000 2

64 LLC Data Volume, UL,GPRS, Background

Kbyte LONG 4 1000 2

65LLC Data Volume, UL,

EDGE, StreamingKbyte LONG 4 1000 2

66LLC Data Volume, UL,

EDGE, Interactive1Kbyte LONG 4 1000 2

67LLC Data Volume, UL,

EDGE, Interactive2Kbyte LONG 4 1000 2

68LLC Data Volume, UL,EDGE, Interactive3

Kbyte LONG 4 1000 2

69LLC Data Volume, UL,

EDGE, BackgroundKbyte LONG 4 1000 2

70LLC Data Volume, DL,

GPRS, StreamingKbyte LONG 4 1000 2

71LLC Data Volume, DL,

GPRS, Interactive1Kbyte LONG 4 1000 2

72LLC Data Volume, DL,

GPRS, Interactive2Kbyte LONG 4 1000 2

73LLC Data Volume, DL,

GPRS, Interactive3

Kbyte LONG 4 1000 2

74LLC Data Volume, DL,GPRS, Background

Kbyte LONG 4 1000 2

75LLC Data Volume, DL,

EDGE, StreamingKbyte LONG 4 1000 2

76LLC Data Volume, DL,EDGE, Interactive1

Kbyte LONG 4 1000 2

77LLC Data Volume, DL,

EDGE, Interactive2Kbyte LONG 4 1000 2

78

LLC Data Volume, DL,

EDGE, Interactive3 Kbyte LONG 4 1000 2

79LLC Data Volume, DL,

EDGE, BackgroundKbyte LONG 4 1000 2

Meas

Name:

(9,44)-- lLCSUBST-- Mean

Outage Time between

Downlink LLC buffer

discard and subsequent of 

Dowlink LLC PDU

Meas Set: 0

Page 204: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 204/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Mean Outage Time forInteractive Services

sec LONG 4 1000 2

1Mean Outage Time for

Streaming Servicessec LONG 4 1000 2

2Mean Outage Time for

Background Servicessec LONG 4 1000 2

Meas

Name:

(9,45)-- aRPAPDAS--

Number Of Attempted

PDCH Assignments (UP/DL)

with ARP priority per Cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Attempted PDCH assignmentsfor an uplink TBF with ARPpriority level 1

N LONG 4 1 0

1

Attempted PDCH assignments

for an uplink TBF with ARP

priority level 2

N LONG 4 1 0

2

Attempted PDCH assignments

for an uplink TBF with ARPpriority level 3

N LONG 4 1 0

3

Attempted PDCH assignments

for an downlink TBF with ARPpriority level 1

N LONG 4 1 0

4

Attempted PDCH assignments

for an downlink TBF with ARP

priority level 2

N LONG 4 1 0

5Attempted PDCH assignmentsfor an downlink TBF with ARP

priority level 3

N LONG 4 1 0

Meas

Name:

(9,46)-- aRPSPDAS--

Number Of Successful PDCH

Assignments (UP/DL) with

ARP priority per Cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Successful PDCH assignments N LONG 4 1 0

Page 205: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 205/222

for an uplink TBF with ARPpriority level 1

1Successful PDCH assignmentsfor an uplink TBF with ARP

priority level 2

N LONG 4 1 0

2

Successful PDCH assignments

for an uplink TBF with ARP

priority level 3

N LONG 4 1 0

3

Successful PDCH assignments

for an downlink TBF with ARPpriority level 1

N LONG 4 1 0

4

Successful PDCH assignments

for an downlink TBF with ARPpriority level 2 N LONG 4 1 0

5

Successful PDCH assignments

for an downlink TBF with ARP

priority level 3

N LONG 4 1 0

Meas

Name:

(9,47)-- aTDTMREQ--

Number of attemps to

establish a DTM (UL/DL) per

Cell

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0

Mobile originated (UL)

direction, while CS dedicated

mode was established

N LONG 4 1 0

1

Mobile originated (UL)

direction, while PS connection

was established

N LONG 4 1 0

2Mobile terminated (DL)direction, while CS dedicated

mode was established

N LONG 4 1 0

3

Mobile terminated (DL)

direction, while PS connection

was established

N LONG 4 1 0

Meas

Name:

(9,48)-- sUDTMREQ--

Number of successful request

to establish a DTM(UL/DL)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 206: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 206/222

0DTM Call with new allocatedof CS part

N LONG 4 1 0

1 DTM Call with CS partunchanged

N LONG 4 1 0

Meas

Name:

(9,49)-- uNSDTMREQ--

Number of unsuccessful

requests to establish a

DTM(UL/DL)

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 MS resource access failure N LONG 4 1 0

1 Expiry of T3107 or T10 N LONG 4 1 0

2 Lack of resources N LONG 4 1 0

Meas

Name:

(9,49)-- uNSDTMREQ--

Number of unsuccessful

requests to establish a

DTM(UL/DL)

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 MS resource access failure N LONG 4 1 01 Expiry of T3107 or T10 N LONG 4 1 0

2 Lack of resources N LONG 4 1 0

3DTM Power Budget HO to

another cellN LONG 4 1 0

Meas

Name:

(9,50)-- mGTTPTH-- GTTP

ThroughputMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 GTTP throughput in UL Kbyte LONG 4 1000 2

1 GTTP throughput in DL Kbyte LONG 4 1000 2

Meas

Name:

(9,51)-- tBFRASSR-- TBF

Resource Assignment RateMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 TBF Resource Assignment N LONG 4 1000 2

Page 207: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 207/222

Rate uplink for interactiveservices

1TBF Resource AssignmentRate uplink for background

services

N LONG 4 1000 2

2

TBF Resource Assignment

Rate downlink for interactive

services

N LONG 4 1000 2

3

TBF Resource Assignment

Rate downlink for backgroundservices

N LONG 4 1000 2

MeasName:

(9,51)-- tBFRASSR-- TBFResource Assignment Rate

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0TBF Resource AssignmentRate uplink for interactiveservices

N LONG 4 1000 2

1

TBF Resource Assignment

Rate uplink for background

services

N LONG 4 1000 2

2TBF Resource AssignmentRate downlink for interactive

services

N LONG 4 1000 2

3TBF Resource AssignmentRate downlink for background

services

N LONG 4 1000 2

Meas

Name:

(9,52)-- nUMPFCADMREJ--

Number of RT PFC

Admitted/Rejected

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Number of RT PFCs admitted N LONG 4 1 0

1 Number of RT PFCs rejected N LONG 4 1 0

Meas

Name:

(9,52)-- nUMPFCADMREJ--

Number of RT PFC

Admitted/Rejected

Meas Set: 1

Counter Name Unit Type Size Scale Digit

Page 208: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 208/222

Id Accuracy

0 Number of RT PFCs admitted N LONG 4 1 0

1 Number of RT PFCs rejected N LONG 4 1 0

Meas

Name:

(9,53)-- mMADFLLC-- Min,

Max and Mean Access Delay

of a first LLC PDU per

traffic class per cell

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0

Min. Access Delay of a first

LLC PDU for Interactive

services

msec WORD 2 1 0

1

Max. Access Delay of a first

LLC PDU for Interactive

services

msec WORD 2 1 0

2

Mean Access Delay of a first

LLC PDU for Interactive

services

msec LONG 4 1000 2

3

Min. Access Delay of a first

LLC PDU for Streamingservices

msec WORD 2 1 0

4

Max. Access Delay of a first

LLC PDU for Streaming

services

msec WORD 2 1 0

5

Mean Access Delay of a first

LLC PDU for Streaming

services

msec LONG 4 1000 2

6

Min. Access Delay of a first

LLC PDU for Backgroundservices

msec WORD 2 1 0

7

Max. Access Delay of a first

LLC PDU for Background

services

msec WORD 2 1 0

8

Mean Access Delay of a first

LLC PDU for Background

services

msec LONG 4 1000 2

Meas

Name:

(9,54)-- mMRARTT-- Radio

Access RTT for DL RLC

PDU's per cell

Meas Set: 0

Page 209: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 209/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Min. RA RTT for DL RLCPDU's

msec WORD 2 1 0

1Max. RA RTT for DL RLC

PDU'smsec WORD 2 1 0

2Mean RA RTT for DL RLC

PDU'smsec LONG 4 1000 2

scannerObjectClass: /BSS/SCANSS7L (10)

Meas

Name:

(10,0)-- dLKSERST--

Duration of Link In-Service

State

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Duration of Link In-Service

Statesec WORD 2 10 1

Meas

Name:

(10,1)-- dSLUNAV--

Duration of Signalling LinkUnavailability - Any Reason Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Duration of Signalling Link 

Unavailability - Any Reasonsec WORD 2 10 1

Meas

Name:

(10,2)-- sLFAILAL--

Number of Signalling Link

Failure - All Reasons

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0Number of Signalling Link 

Failure - All ReasonsN WORD 2 1 0

scannerObjectClass: /BSS/SCANTRX (11)

Meas (11,0)-- iLUPLKIC-- Meas Set: 0

Page 210: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 210/222

Name: Interference Level

measurement on Uplink idle

channels

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Channel 0 - Band 1 N WORD 2 1 0

1 Channel 0 - Band 2 N WORD 2 1 0

2 Channel 0 - Band 3 N WORD 2 1 0

3 Channel 0 - Band 4 N WORD 2 1 0

4 Channel 0 - Band 5 N WORD 2 1 0

5 Channel 1 - Band 1 N WORD 2 1 0

6 Channel 1 - Band 2 N WORD 2 1 0

7 Channel 1 - Band 3 N WORD 2 1 0

8 Channel 1 - Band 4 N WORD 2 1 0

9 Channel 1 - Band 5 N WORD 2 1 0

10 Channel 2 - Band 1 N WORD 2 1 0

11 Channel 2 - Band 2 N WORD 2 1 0

12 Channel 2 - Band 3 N WORD 2 1 0

13 Channel 2 - Band 4 N WORD 2 1 0

14 Channel 2 - Band 5 N WORD 2 1 015 Channel 3 - Band 1 N WORD 2 1 0

16 Channel 3 - Band 2 N WORD 2 1 0

17 Channel 3 - Band 3 N WORD 2 1 0

18 Channel 3 - Band 4 N WORD 2 1 0

19 Channel 3 - Band 5 N WORD 2 1 0

20 Channel 4 - Band 1 N WORD 2 1 0

21 Channel 4 - Band 2 N WORD 2 1 0

22 Channel 4 - Band 3 N WORD 2 1 0

23 Channel 4 - Band 4 N WORD 2 1 0

24 Channel 4 - Band 5 N WORD 2 1 0

25 Channel 5 - Band 1 N WORD 2 1 0

26 Channel 5 - Band 2 N WORD 2 1 0

27 Channel 5 - Band 3 N WORD 2 1 0

28 Channel 5 - Band 4 N WORD 2 1 0

29 Channel 5 - Band 5 N WORD 2 1 0

30 Channel 6 - Band 1 N WORD 2 1 0

Page 211: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 211/222

31 Channel 6 - Band 2 N WORD 2 1 0

32 Channel 6 - Band 3 N WORD 2 1 0

33 Channel 6 - Band 4 N WORD 2 1 0

34 Channel 6 - Band 5 N WORD 2 1 0

35 Channel 7 - Band 1 N WORD 2 1 0

36 Channel 7 - Band 2 N WORD 2 1 0

37 Channel 7 - Band 3 N WORD 2 1 0

38 Channel 7 - Band 4 N WORD 2 1 0

39 Channel 7 - Band 5 N WORD 2 1 0

MeasName: (11,1)-- tRANAVTI--Transceiver Available Time Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Transceiver Available Time sec WORD 2 10 1

scannerObjectClass: /BSS/SCANBTSOHOS (12)

MeasName:

(12,0)-- aTOISHDO--

Attempted OutgoingIntersystem Handover per

neighbourcell per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7Forced Handover due to O_MIntervention

N WORD 2 1 0

8Forced Handover due to

PreemptionN WORD 2 1 0

9 Sufficient UMTS coverage N WORD 2 1 0

Page 212: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 212/222

Meas

Name:

(12,0)-- aTOISHDO--

Attempted Outgoing

Intersystem Handover per

neighbourcell per cause

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 06 Directed Retry N WORD 2 1 0

7Forced Handover due to O_M

InterventionN WORD 2 1 0

8Forced Handover due to

PreemptionN WORD 2 1 0

9 Sufficient UMTS coverage N WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

Meas

Name:

(12,1)-- sUOISHDO--Successful Outgoing

Intersystem Handover per

neighbourcell per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7Forced Handover due to O_M

InterventionN WORD 2 1 0

8Forced Handover due to

PreemptionN WORD 2 1 0

9 Sufficient UMTS Coverage N WORD 2 1 0

Page 213: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 213/222

 

Meas

Name:

(12,1)-- sUOISHDO--

Successful Outgoing

Intersystem Handover per

neighbourcell per cause

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7Forced Handover due to O_M

InterventionN WORD 2 1 0

8Forced Handover due to

PreemptionN WORD 2 1 0

9 Sufficient UMTS Coverage N WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

Meas

Name:

(12,2)-- uNOISHDO--

Unsuccessful Outgoing

Intersystem Handover per

neighbourcell per cause

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 0

4 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7Forced Handover due to O_M

InterventionN WORD 2 1 0

8Forced Handover due toPreemption

N WORD 2 1 0

Page 214: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 214/222

9 Sufficient UMTS coverage N WORD 2 1 0

Meas

Name:

(12,2)-- uNOISHDO--Unsuccessful Outgoing

Intersystem Handover per

neighbourcell per cause

Meas Set: 1

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Uplink Quality N WORD 2 1 0

1 Downlink Quality N WORD 2 1 0

2 Uplink Strength N WORD 2 1 0

3 Downlink Strength N WORD 2 1 04 Distance N WORD 2 1 0

5 Better Cell N WORD 2 1 0

6 Directed Retry N WORD 2 1 0

7Forced Handover due to O_MIntervention

N WORD 2 1 0

8Forced Handover due to

PreemptionN WORD 2 1 0

9 Sufficient UMTS coverage N WORD 2 1 0

10 Forced handover due to DTM N WORD 2 1 0

scannerObjectClass: /BSS/SCANFBTSM (13)

Meas

Name:

(13,0)-- aBISPDIS-- Abis

Pool DistributionMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Single Abis subchannel(1x16Kbps) usage rate for CS

traffic

% WORD 2 100 2

1

Single Abis subchannel

(1x16Kbps) usage rate for PO

traffic

% WORD 2 100 2

2

Concatenated Abis

subchannels (2x16Kbps) usage

rate

% WORD 2 100 2

3 Concatenated Abis % WORD 2 100 2

Page 215: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 215/222

subchannels (3x16Kbps) usagerate

4Concatenated Abissubchannels (4x16Kbps) usage

rate

% WORD 2 100 2

5

Concatenated Abis

subchannels (5x16Kbps) usage

rate

% WORD 2 100 2

Meas

Name:

(13,1)-- aBISPSUP-- Abis

Pool SupervisionMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Mean number of defined Abis

subchannelsN LONG 4 1000 2

1Mean number of availableAbis subchannels

N LONG 4 1000 2

2Mean number of allocated

Abis subchannelsN LONG 4 1000 2

3Max number of allocated Abis

subchannelsN WORD 2 1 0

4All available Abis subchannels

allocated time sec WORD 2 1 0

5Number of successful Abissubchannel seizures

N WORD 2 1 0

6Number of unsuccessful Abis

subchannel seizure attemptsN WORD 2 1 0

7Number of Abis subchannelmodifications

N WORD 2 1 0

Meas

Name:

(13,2)-- iFRMABSC-- I-

Frame Measurement on AbisInterface on BSC side

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Transmitted I-Frames (from BSC side)

N LONG 4 1 0

1

Number of discarded I-Frames

from the transmit queue on

BSC side

N LONG 4 1 0

Page 216: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 216/222

2Number of Received I-Frames(on BSC side)

N LONG 4 1 0

3 Number of Badly Received I-Frames (on BSC side)

N LONG 4 1 0

scannerObjectClass: /BSS/SCANDPC (14)

Meas

Name:

(14,0)-- tMSGREC-- Total

messages receivedMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Total messages received N LONG 4 1 0

Meas

Name:

(14,1)-- tMSHHDL-- Total

messages handledMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Total messages handled N LONG 4 1 0

Meas

Name:

(14,2)-- rFDBCUN-- Routing

failure DPC unavailable Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Routing failure DPC

unavailableN LONG 4 1 0

Meas

Name:

(14,3)-- rFSUBUN-- Routing

failure Subsystem

unavailable

Meas Set: 0

CounterId Name Unit Type Size Scale DigitAccuracy

0Routing failure Subsystemunavailable

N LONG 4 1 0

Meas

Name:

(14,4)-- tCMSGREC-- Total

Connectionless Message

Received

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Page 217: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 217/222

0Total Connectionless MessageReceived

N LONG 4 1 0

Meas

Name:

(14,5)-- tCMSGSND-- Total

Connectionless Message SentMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Total Connectionless MessageSent

N LONG 4 1 0

Meas

Name:

(14,6)-- nMSUTRAS--

Number of Message Signal

Units Transmitted

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of Message Signal

Units TransmittedN LONG 4 1 0

Meas

Name:

(14,7)-- nMSUREC-- Number

of message signal units

received

Meas Set: 0

CounterId Name Unit Type Size Scale DigitAccuracy

0Number of message signal

units receivedN LONG 4 1 0

Meas

Name:

(14,8)-- lOCAUTCH-- Local

automatic changeoverMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Local automatic changeover N LONG 4 1 0

Meas

Name:

(14,8)-- lOCAUTCH-- Local

automatic changeoverMeas Set: 255

Counter

IdName Unit Type Size Scale

Digit

Accuracy

Meas

Name:

(14,9)-- dLKUNCON--

Duration of Linkset

Unavailable Condition

Meas Set: 0

Page 218: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 218/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Duration of LinksetUnavailable Condition

sec WORD 2 10 1

Meas

Name:

(14,9)-- dLKUNCON--

Duration of Linkset

Unavailable Condition

Meas Set: 255

Counter

IdName Unit Type Size Scale

Digit

Accuracy

MeasName:

(14,10)-- nASPAVUN--

Number of ASP Transitionfrom Available to

Unavailable

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Number of ASP Transitionfrom Available to Unavailable

N LONG 4 1 0

Meas

Name:

(14,11)-- dASPUNT--

Duration of the ASP

unavailable time

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Duration of the ASPunavailable time

sec WORD 2 10 1

scannerObjectClass: /BSS/SCANNSVC (15)

Meas

Name:

(15,0)-- mFRLDATA--Utilization of frame relay

links on the Gb interface per

NSVC

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Mean data throughput per

NSVC in uplink kbit/s LONG 4 1000 2

1 Mean data throughput per kbit/s LONG 4 1000 2

Page 219: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 219/222

NSVC in downlink 

scannerObjectClass: /BSS/SCANATMVP (16)

Meas

Name:

(16,0)-- aTMVPINCCEL--

Number of Incoming CellsMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Incoming Cells N LONG 4 1 0

MeasName: (16,1)-- aTMVPOUTCEL--Number of Outgoing Cells Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Outgoing Cells N LONG 4 1 0

Meas

Name:

(16,2)-- aTMVPINCOAM--

Number of Incoming OAM

Cells

Meas Set: 0

Counter

Id Name Unit Type Size Scale

Digit

Accuracy

0 Incoming OAM Cells N LONG 4 1 0

Meas

Name:

(16,3)-- aTMVPOUTOAM--

Number of Outgoing OAM

Cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Outgoing OAM Cells N LONG 4 1 0

Meas

Name:

(16,4)-- aTMVPUSRCEL--

Number of Incoming user

information cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Incoming User Information

CellsN LONG 4 1 0

Page 220: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 220/222

Meas

Name:

(16,5)-- aTMVPLSTCEL--

Number of Detected Lost

cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Lost Cells N LONG 4 1 0

Meas

Name:

(16,6)-- aTMVPCONGES--

Usage ratio of the VPMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 VP Usage Ratio % WORD 2 100 2

Meas

Name:

(16,7)-- aTMVPEGRCLR--

Discarded Cells Ratio in

Transmission

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Discarded Cells Ratio inTransmission

% WORD 2 100 2

Meas

Name:

(16,8)-- aTMVPINGCLR--Discarded Cells Ratio in

Reception

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Discarded Cells Ratio in

Reception% WORD 2 100 2

scannerObjectClass: /BSS/SCANATMVC (17)

Meas

Name:

(17,0)-- aTMVCINCCEL--

Number of Incoming CellsMeas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Incoming Cells N LONG 4 1 0

Meas

Name:

(17,1)-- aTMVCOUTCEL--

Number of Outgoing CellsMeas Set: 0

Page 221: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 221/222

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Outgoing Cells N LONG 4 1 0

Meas

Name:

(17,2)-- aTMVCINCOAM--

Number of Incoming OAM

Cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Incoming OAM Cells N LONG 4 1 0

MeasName:

(17,3)-- aTMVCOUTOAM--

Number of Outgoing OAM

Cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Outgoing OAM Cells N LONG 4 1 0

Meas

Name:

(17,4)-- aTMVCUSRCEL--

Number of Incoming user

information cells

Meas Set: 0

CounterId

Name Unit Type Size Scale DigitAccuracy

0Incoming User Information

CellsN LONG 4 1 0

Meas

Name:

(17,5)-- aTMVCLSTCEL--

Number of Detected Lost

cells

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0 Lost Cells N LONG 4 1 0

Meas

Name:

(17,6)-- aTMVCEGRCLR--

Discarded Cells Ratio in

Transmission

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Discarded Cells Ratio in

Transmission% WORD 2 100 2

Page 222: BatranaDeveloper_MeasLayout_9_0

7/29/2019 BatranaDeveloper_MeasLayout_9_0

http://slidepdf.com/reader/full/batranadevelopermeaslayout90 222/222

 

Meas

Name:

(17,7)-- aTMVCINGCLR--

Discarded Cells Ratio in

Reception

Meas Set: 0

Counter

IdName Unit Type Size Scale

Digit

Accuracy

0Discarded Cells Ratio inReception

% WORD 2 100 2