Top Banner
BATIMENT R+2 OSSATURE BOIS 3 BATIMENTS – 620 M² HABITABLE – REPARTIS EN 12 LOGEMENTS TRES PEU DE PARTIES COMMUNES A ENTRETENIR ENTREES INDEPENDANTES – PARTAGE DE CAGE D’ESCALIERS PAR PALIER MACONNERIE SOUS-SOL OU VIDE-SANITAIRE – SYSTÈME PREFABRIQUE – PRE-DALLE
6

BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

Oct 31, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

BATIMENT R+2 OSSATURE BOIS

3 BATIMENTS – 620 M² HABITABLE – REPARTIS EN 12 LOGEMENTS

TRES PEU DE PARTIES COMMUNES A ENTRETENIR

ENTREES INDEPENDANTES – PARTAGE DE CAGE D’ESCALIERS PAR PALIER

MACONNERIE SOUS-SOL OU VIDE-SANITAIRE – SYSTÈME PREFABRIQUE – PRE-DALLE

Page 2: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

BATIMENT R+2 OSSATURE BOISCONCEPTION – PREFABRIQUE EN ATELIER

MUR DOUBLE CONTREVENTEMENT INT/EXT – ISOLATION RENFORCEE 160 + 45 MM INT

CAISSON DE PLANCHER PREFABRIQUE OSSATURE DE 240, SUSPENTE, BA13, FINITION 3 PLIS DE 16 MM, DESSUS NOVOPAN DE 19 MM, RAVOIRAGE, LAINE DE ROCHE, CHAPE LIQUIDE, CARRELAGE ET PARQUET

CAISSON DE TOITURE PREFABRIQUE, ISOLATION PAR L’EXTERIEUR 35 MM FIBRE DE BOIS

CHAUFFAGE INDIVIDUEL GAZ A CONDENSATION AVEC PRODUCTION EAU CHAUDE OU CHAUFFAGE ELECTRIQUE INFRACABLE COUPLE A DES PANNEAUX PHOTOVOLTAIQUES ET TRIPLE VITRAGE

Page 3: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

RESULTAT RT 2012

51 A 90 B

RESULTAT ACOUSTIQUETest aux chocs – exigence de 58 DbRésultat -> 47 Db soit -23%

BRUITS AERIENSExigence supérieure à 53 DbRésultat -> 64 Db soit +20%

Page 4: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

BALCON METALLIQUEESCALIER

PALIER

POSE EN MEME TEMPS QUE LE MONTAGE

SECURITE DES HOMMES ET DES BIENS

Page 5: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

DEMARRAGE DES TRAVAUX / RECEPTION DES APPARTEMENTS 5 MOIS

COUT DE COPROPRIETE 15/20 € MOIS

250 € ANCONSOMMATION PRODUCTION CHALEUR ET EAU CHAUDE

Page 6: BATIMENT R+2 OSSATURE BOISafcobois.fr/wp-content/uploads/2018/05/2018-BAT-R2-PRESENTATIO… · batiment r+2 ossature bois conception –prefabrique en atelier mur double contreventement

www.gardavaud.com

NOUS SOMMESFIERS DE NOS REALISATIONS…

GARDAVAUD HABITATIONS VOUS REMERCIE DE VOTRE

ATTENTION