Water Efficiency SINK MIXER CLEANING RECOMMENDATIONS Tech Page Version 2 SPECIFICATIONS Recommended use Domestic, hotel and commercial Colour availability Chrome Pressure rating Temperature rating Maximum continuous working temperature 80° 4 Stars Flow Rate 7.5 L/min . 6 Stars. Flow Rate 4.5L/min Suitable Hot Water Units Standards AS/NZS 3718 page 1 of 2 We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Conditions on the last page. 258 220 129 157 53 MAX38 Maximim continuous operating pressure 1000 kPa. Note: For best performance and longer life we recommend 150-500 kPa. Hot and cold water inlet pressure should be equal. Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Dimensions are nominal measurements only. Storage Tank: Yes Continuous Flow: Yes Gravity Feed: Not suitable BASE MK2
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Water Efficiency
SINK MIXER
CLEANING RECOMMENDATIONS
Tech Page Version 2
SPECIFICATIONSRecommended use Domestic, hotel and commercial
Colour availability Chrome
Pressure rating
Temperature rating Maximum continuous working temperature 80°
4 Stars Flow Rate 7.5 L/min.
6 Stars. Flow Rate 4.5L/min
Suitable Hot Water Units
Standards AS/NZS 3718
page 1 of 2
We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Conditions on the last page.
258220
129
157
53M
AX
38
Maximim continuous operating pressure 1000 kPa.
Note: For best performance and longer life werecommend 150-500 kPa.
Hot and cold water inlet pressure should be equal.
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registeredtrade people. The manufacturer/distributor reserves the right to vary specifications or delete models fromtheir range without prior notification. Dimensions and set-outs listed are correct at time of publicationhowever the manufacturer/distributor takes no responsibility for printing errors. Dimensions are nominal measurements only.
Storage Tank: Yes
Continuous Flow: Yes
Gravity Feed: Not suitable
BASE MK2
SINK MIXER
Plumbers, please ensu re a copy of the installation instructions is left with the end user for futu re reference
INSTALLATION
NoteThe installation must comply with requirements AS/NZS 3500. Mixer must be installed by a licenced plumber.
ImportantYour mixer comes to you already factory assembled and tested. We do not recommend the dismantling of any internal part of the mixer. The mixers are factory tested and sealed so as to give the best performace.
1. Please flush out new pipe work prior to connecting the newmixer.
2. All mixers should be installed with isolating stop cocks (Arcobrand recommended).
3. This tap is suitable for high pressure applications where bothhot and cold water supply pressures are at 150kPa or above.
4. Place the washer into position.
5. Fit the tap body (10) into the sink hole making sure first that theflexible connectors (19,20) are firmly tightened into the base of thebody.
6. Do not use teflon tap on threads.
7. From underneath apply your washer (15) prior to positioning thehorse shoe plate (16).
8. Lock the mixer onto the sink or benchtop by tightening the locknut s(18).
Servicing - Replacement of Cartridge1. Remove cap (3) and unscrew the grub screw (2) using allenkey.
2. Lift off handle and remove the cartridge dome (4), unscrewbrass locking nut (5) and lift out cartridge (6).
3. Replace the cartridge (6), replace the brass locking nut (5),cartridge dome (4) and replace handle (1). Tighten grub screw (3)and push in indicator cap (2).
2
3
103370003RECE Sink Mixer
103370003RECE
2Theory External Area[cm ]
1:4Scale
mmDrawing Unit
Theory Area[cm ]
Theory Weight [g]
EditionASMMaterial
Item Code
Description
MAIN PLAN LIMITED
Page 1;Total Pages 1
Authorized
Verify
Proofread
Designer
2
DateDesignRevised ContentMarking
Drawing Angle
Useful Measurement
Key Measurement
Measurement Tolerance Value (Not Marked) Angle Tolerance Value (Not Marked)
Connect the flexible hoses to the hot and cold isolating stops, hand tighten plus half a turn of the nut to provide a watertight joint. Ensure that hoses are not under tension, twisted or kinked and if bent have a minimum radius of 30mm.