1 Presentation to cover: • Plant water balance • Cooling water System • Water treatment plant • Condensate polishing unit • Effluent treatment plant • HVAC • Fire protection system
Dec 05, 2015
1
Presentation to cover:
• Plant water balance
• Cooling water System
• Water treatment plant
• Condensate polishing unit
• Effluent treatment plant
• HVAC
• Fire protection system
2
Plant Water Balance• Plant water balance drg
• Drg shows:
� Source of water supply
� Water qualities
� Consumers for different qualities
� Flow rates
� Storages
� Effluents
• Use of PWB� Plan for raw water supply
� Sizing of piping, pumps, storages
� Plan for effluents treatment / disposal
� Water consumption optimisation
� Storage sizes for use in plot plan
� Development of Plot Plan
3
Cooling Water System• Condenser cooling water system
– To remove heat of condensation from the condenser• Closed Cycle System
• Open Cycle system
– Major equipments / buildings:• CW PH
• CW Pumps
• Condenser
• Cooling towers
• Make up system
• Blow down system
• Tube cleaning system
• Debris filter system
• Chlorination system
– Flow rate 30000, 58000, 70000 m3/h for 250, 500 and 660 MW units
– Temperature rise 8.5 to 10 C
– Flow velocity in pipe 2 – 2.6 m/s
• Auxiliary cooling water system
• Closed cycle cooling water system
4
Water treatment
• Water analysis
• Pre-treatment
– Clarifier (To remove turbidity to a level of 15 parts per million -ppm)
• Chemicals used:
– Alum
– Lime
– PE
• Aeration
• Coagulation
• Flocculation
– Filteration (To remove turbidity to a level of 2 to 5 ppm)
• No chemical dosing
• Multi-grade gravity or pressure filter
5
Water treatment• Dissolved solids in water:
– Cations• Na, Ca, Mg, K, Fe etc
– Anions• HCO3, CO3, OH, Cl, SO4, NO3 etc
• Demineralisation – To remove color, smell (ACF)
– To remove Cations (SAC, WAC)
– To remove Anions (SBA, WBA)
– Treated water (DM) analysis• pH 6.8 to 7.2• Conductivity 0.1 microS / cm• Silica 0.01 to 0.02 mg/L as SiO2
• Chemicals used:– Acid
– Alkali
– Technologies:• Cation, Anion, Mix-bed exchangers• Reverse-Osmosis and Mix-Bed technology
6
Water treatment
• Chlorination (to dose active chlorine solution)
– To control
• Bio growth
• Biological Oxygen Demand
– Chlorination is done in:
• Raw water intake
• Pre-treatment plant
• CW system
• Potable water
– Technologies:
• Gas chlorination
• Electro-chlorination
- Chlorination dosing rates
7
Condensate Polishing Unit• Power Cycle System flow Scheme
– Typical Water quality in power cycle system
CPU Inlet CPU-Outlet (maximum)
• Conductivity 0.1 microS / cm
• pH 8.8 to 9.3 -• Total dissolved solids 95 25 ppb
• Ammonia 100 -
• Chlorides 10 2 ppb
• SiO2 20 5 ppb
• Crud (start up) 500 70 ppb• Cu 5 3 ppb
• Fe 50 5 ppb
• Na (CW leakage) 2000 20 ppb
– Source of impurities:• DM make up
• Corrosion products
• CW system leak
• Potable water
– Technologies:• Cation-Anion Mix-bed (Resin Ion Exchange)
8
Effluent Treatment Plant• Central Pollution Control Board (CPCB), State Pollution Control Boards (SPCBs)
• ETP Diagram
• Sources of liquid effluents– Condenser CW system blow down
– Boiler blow-down– DM Plant / CPU regeneration waste
– Clarifier sludge
– Filter back wash
– Oily effluent
– Service / potable water / STP waste
• Process– Collection of effluents
– API / TPI for oily Effluents– Lamella for removing turbidity
– Collection in Central Monitoring Basin
– Reuse without further treatment
– Treatment for reuse
• Permissible limits for disposal of liquid effluents:– PH 6.5 to 8.5
– Suspended solids < 100 ppm– Oil and grease < 5 – 10 ppm
– Residual Chlorine < 0. 5 ppm
– Temperature 5 - 7 C
9
Heating Ventilation and Air-Conditioning• Air Conditioning
– For comfort
– Requisite environment for instruments and equipment
– Diagram
• Ambient conditions for Summer, Winter and Rainy-season are site specific data
• Conditioned environment:– Dry bulb-temperature 22 to 24 C
– Humidity 50 + - 5%
• A/C is provided for:– Main control-room
– ESP control room
– CHP, AHP control rooms
– Control room having Electronic equipments
– Laboratory– Office accommodation – customer specific
• Major equipments:– Chiller
– CT system
– Air Handling Unit
– Ducting
– Heating system
10
Heating Ventilation and Air-Conditioning• Ventilation
– For comfort
– Air quality (Air changes)
– Diagram
• Ambient conditions for Summer are site specific data
• Evaporative Cooling System for Turbine hall– Fan
– Ducting
– Air Washer
– Water system
• Air changes:– Laboratory 10
– Toilets, Pantries 15
– Chemical house 15
– Pump-houses 15
– TG hall 6
– Canteen 20
11
Fire Detection and Protection System• Codes
– Tariff Advisory Committee - TAC (India)
– National Fire Protection Association - USA (NFPA) for contracts outside India
• Category of Hazard (TAC)
– Coal fired Power Plants Ordinary hazard
– Open Cycle Gas Turbine Projects Ordinary hazard
– Combined cycle power project Ordinary hazard
– Sub-stations Light hazard
– Hydro-projects Light hazard
• Systems – Hydrant System (Drawing)
– Spray system (Drg)
– Foam System (Drg)
– Portable / mobile (Fire Extinguishers, Fire –tender)
• Major buildings / Equipments:– Fire water PH
– Hydrant Pumps
– Jockey pumps
– Spray water pumps
– Ring mains
– Hydrant / water monitors
– Risers and hose rolls
– Detection system
– Control and monitoring system
124.183.73mg/lIron as Fe24
BDLBDLmg/lCopper as Cu23
BDLBDLmg/lBOD (3 days)22
6.66.9mg/lDissolved oxygen21
24005300umohs/cmConductivity @ 25 degC20
12080NTUTurbidity19
14903408mg/lTotal Dissolved Solids18
286179mg/lSuspended Solids17
119.7mg/lDissolved Silica16
400716716mg/lTotal Hardness as CaCo314
NILNILmg/lPhenolp Alkalinity as CaCo313
169165165mg/lMethyl Orange alkalinity as CaCo312
2.433.790123.07mg/lNitrate as CaCo311
5472.115475mg/lSulphate as CaCo310
10241835.462588mg/lChloride as CaCo39
NILNILmg/lCarbonates as CaCo38
169201.22165mg/lBicarbonates as CaCo37
21.823.203129.7mg/lPotassium as CaCo35
817957.3392087mg/lSodium as CaCo34
240102.041500mg/lMagnesium as CaCo33
16086.4216mg/lCalcium as CaCo32
8.18.........pH1
21/02/07UnitParameterS. No
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34