Industrial Quality, Commercial LooksBig Ass Fans has created the first and only industrial-grade ceiling fan engineered specifically for commercial spaces. Heavy duty aluminum alloy, SAE Grade 8 bolts and redundant safety features means that Element is not just another pretty face but a tough workhorse that will move lots of air efficiently and look great doing it.
Gearless Direct Drive MotorThe brain of the Element lies in its revolutionary, specially-designed motor. We eliminated the noisy, inefficient gearbox and replaced it with a high powered, low speed electronically controlled motor. This intelligent system was designed by Big Ass Fans engineers solely for the Element. Its advanced motor drives the
10 blades of the 12'. diameter Element, for an oil-free, silent fan that is virtually maintenance free.
Increased Air Movement with Less DragThe patented airfoil and winglet system of Element produces large volumes of airflow with less drag. Turbulence is eliminated and quiet operation enhanced by the aerodynamic design.
Endless Customization OptionsThe options are endless with Element. Choose a custom color or finish for your Element that will allow it to blend seamlessly into any dcor. An innovative stationary hub platform allows for the attachment of lights, speakers, surveillance systems and other electronics.
Winter DestratificationBring superheated air at the ceiling down to the employee level -Turn down your thermostat, provide a warmer environment AND cut -thousands off your energy bills
Additional BenefitsAssists in the removal of contaminant and heat -Eliminates the need for multiple high velocity fans -Helps reduce condensation on floors and equipment -Virtually silent operation -
Recommended ApplicationsLarge buildings with high ceilings: >26' (8 m) -Facilities where maximum possible air -movement is essential (e.g., non-air conditioned facilities)
Controller FactsMeet all NEC specifications -UL listed for U.S. and Canada -Allen-Bradley VFD -NEMA 1 Box -0-100% Speed Control -
AFTER A BIG ASS FANBEFORE A BIG ASS FAN
75˚ (23.9˚C) at the ceiling
74˚ (23.3˚C) on the floor24’ POWERFOILTM
144 ft. (68m)POWERFOIL 6X FAN DIAMETER
60˚ (16˚C) on the floor
90˚ (32˚C) at the ceiling
DESTRATIFICATION
SUMMER COOLING
- Dramatically lowers capital, operating and maintenance costs
MORE COVERAGEDeeper jets of air maximize effective coverage area
TECHNICAL SPECIFICATIONSMOTOR SIZE
2.0 hp
CFM
364,354 cfm*
EFFECTIVE COVERAGE AREA
30,000 sq. feet
FAN MODEL #
P24PLUS
MORE AIRThe PowerfoilPlus’ unique hybrid airfoil creates deeper jets of air
MORE COMFORTABLE PEOPLEDeeper jets of air and greater reach combine to move air over obstacles
20,000 sq, feet
+10,000 sq. feet
The PowerfoilPlus maintains effective cooling airspeedsmeasured at head height or 67” off the ground over a 50% larger coverage area than previous fan models.
Normally, small type is filled with information that companies want to hide. Why would we want to hide thebest performance numbers on the market? Our fans havealways carried a CFM rating, the PowerfoilPlus is noexception. But, CFM doesn’t tell the whole story. ThePowerfoilPlus isn’t just about more air. It’s about more
efficient and effective air. The hybrid airfoil creates deeperjets of air that maintain higher airspeeds further from thefloor, without using more energy.
More air over larger spaces for just pennies-per-hour. Isn’tthat why you’re considering big fans in the first place?
Big Fan Technology for Small SpacesPivot's compact 6ft. diameter gives you all theperformance of a Big Ass Fan specially engineered for tight spaces. The patented new airfoil and winglet combination maximizes airflow.
Get Incredible FlexibilityPivot up, down and from side to side. Pivot lets you aim your air with 73 unique mounting positions.
• Compact 5.5 X 9 inch profile• Digital speed read-out
Big Ass Fans touch-pad controllerallows you to easily change air speeds depending on temperature conditions and level of activity.
DESIGNED TO BE SEEN, BUILT TO LASTAll the strength, reliability and safety features to operateworry-free in tough environments, with sleek stylingappropriate for showing off.
FAN DIAMETER: 6 ft. (1.8 m)
AIR DISP. @ MAX SPEED: 29,081 cfm (13,720 I/s)
MOTOR SIZE: 1.0 HP
SUPPLY VOLTAGE: 115/230v Single
230/460v Three
MOTOR FLA: 12A @ 115v 1 , 6A @ 230v 1
3.2A @ 230v 3 , 1.6A @ 460v 3
RPM @ 60hz: 180 rpm
AIRFOIL LENGTH: 28" (71 cm)
FAN WEIGHT: 199 lbs. (90 kg)
CAGE DIAMETER: 74.5" (189.2 cm)
DBA @ MAX SPEED: 72 dba @ 180 rpm
AIR SPEED @ 70" FROM CENTER: 200 fpm
What’s Your Favorite Position?
• Easy-to-install cage• Patented airfoil and winglet combo create maximum air movement• Exclusive foil couplings reduce noise at connections points for quiet operation• Flexible mounting system permits you to hang the fan wherever and however you want
FREE AIR DISPLACEMENT @ 170 RPM 99,600 cfm. (47,006 L/S)
SPEED @ 60Hz 170 RPM
MAX. AMP 3.24@230V, 1.62@460V
With so many variations in large warehouses and industrialbuildings, Big Ass Fans has developed an 8 ft. (2m) enclosed vertical fan. When high-volume/low-speed Big Ass Fans cannotbe installed on the ceiling because of obstructions, or when a movable fan is desired, the newly-developed vertical version is the preferred way to provide a comfortable environment forworkers. This fan is also used in agricultural applications, including horse barns, hog barns and poultry facilities.
Big Ass Fans are available with VESDA® (Very Early Warning Smoke Detection Apparatus) by Xtralis®. In addition, previously installed Big Ass Fans can be retrofitted to include VESDA. Models eligible for VESDA system include Powerfoil™, PowerfoilPlus™, Wickerbill, and Standard fans.
The VESDA smoke detection system is a proven solution in high volume spaces, making it the perfect complement for a Big Ass Fan. VESDA works with the Big Ass Fan by detecting smoke at the earliest stage, and then sending a signal to automatically stop the fan. This shutdown feature is designed specifically for Big Ass Fans to be used in facilities equipped with Early Suppression Fast Response (ESFR) sprinkler systems. The only proven solution on the market verified by third party testing.
VESDA uses a series of pipes to actively draw air through sample points and transports the air back to a single VESDA detector for analysis.This detector looks for smoke particles by laser based light scattering and reports when smoke is present in the area.
VESDA Provides:Earliest possible warning of an imminent fire hazard™ Complete shutdown of fan system at the earliest sign of smoke, long ™ before ESFR systems activateTime to initiate a flexible, appropriate response™ The only proven solution on the market verified by third party testing™
12ft Powerfoil™10ft Powerfoil™24 VESDA®
Specifications
Voltage 24V DC Nominal (18-30 V DC)
Current @ 24 VDC 410 mA nominal, 490 mA in alarm
IP Rating IP30
VESDA Dimensions 9 7/8 in. x 7 1/8 in. x 3 1/2 in (25.1 cm x 18.1 cm x 8.9 cm)
VESDA Power Supply Dimensions 13.9 in. x 9 in. x 4.5 in. (35.3 cm x 22.9 cm x 11.4 cm)
12ft Powerfoil™10ft Powerfoil™ 25Fan ControlsBasic Fan Control
Engineered specifically for our fans, these controllers incorporate state-of-the-art electronics to ensure efficient and problem-free operation.
UL listed for United States and Canada™ Available with CE marking™ 100-125V (1 Phase), 200-250V (1 Phase), 200-250V (3 Phase), 400-480V (3 Phase), ™ 575-600V (3 Phase)NEMA type 1 (IP20) enclosure™ Enclosure dimensions: 12™ (30.5cm) x 20™ (50.8cm) x 8.62™ (21.9cm)™ Variable frequency drive™ Start and stop switch™ Disconnect switch™ Internal fusing™ Door-mounted potentiometer™ Load Reactor (480 volts only)™
460 VOLT
Three Phase
8.85” (22.5 cm)
5.06” (12.9 cm)
Max Depth:5.86” (14.9 cm)
Ø .275” (7 mm)
Agricultural Fan Control
UL listed for United States and Canada™ 200-250V (1 Phase), 200-250V (3 Phase), 400-480V (3 Phase)™ NEMA type 4X (IP65) enclosure (Watertight, Dust-tight and Corrosion-Resistant)™ Enclosure dimensions: 7.15™ (18.1cm) x 9.25™ (23.5cm) x 7.25™ (18.4cm)™ Variable Frequency Drive™ Start and Stop Switch™ Door-mounted potentiometer™
• Powder coated• 3” x 3” steel tube (8cm x 8cm)• All steel is 0.25” thick (0.60cm)• Upper plate is designed to fit 7” to 15” size I-beam (also interfaces with glulam clamps) (18cm to 38cm)• Spacers provided for thick beams• The single pivot adjustable mount with clamping mechanism designed by Big Ass Fans is the ultimate in fan stability
UNIVERSAL FAN MOUNTS
Single Pivot Mount Kit for 7” to 10” (18cm to 25cm) Beam part # SP710
Single Pivot Mount Kit for 10” to 15” (25cm to 38cm) Beam part # SP1015
Additional drop bar (greater than 1ft. (0.3m)) part # UMAZ (requested length in ft. and inches)
In Figure 1, the fan moves air downward in a column equal to thefan's diameter. At standard speed, a20ft. (6m) Big Ass Fan creates a gentlecurrent of air 9ft. (2.7m) deep. The airthen redirects outward in all directions.
As illustrated in Figure 4, multiple fanswork in harmony to create pressurefronts that facilitate the convection-likecycle of airflow. This ensures adequateand effective airflow over larger areas.
In Figure 2, outward air movement continues until reaching verticalobstructions. Air then redirects upward,pulled by the fan's inflow current andpushed by the ensuing airflow. Big AssFans move air over an area six times itsdiameter in every direction.
In Figure 3, this inflow causes air toclimb, plateau and turn inward. As partof an inertia-driven system, air is redirected downward as part of convection-like current. Here, the 20ft.(6m) fan is affecting 14,400 sq. ft. of air.
Figure 1
Fan Diameter Suggested Spacing
Minimum Distancefrom ceiling deck
8 ft. (2.4m) 6x fan diameter 3 ft. (0.91m)10 ft. (3.0m) 6x fan diameter 3 ft. (0.91m)12 ft. (3.6m) 6x fan diameter 3 ft. (0.91m)14 ft. (4.3m) 6x fan diameter 4 ft. (1.22m)16 ft. (4.9m) 6x fan diameter 4 ft. (1.22m)18 ft. (5.5m) 6x fan diameter 4 ft. (1.22m)20 ft. (6.1m) 6x fan diameter 5 ft. (1.52m)24 ft. (7.3m) 6x fan diameter 5 ft. (1.52m)
85.34m) Distribution Center• (3) 24 ft. (7.32m) Big Ass Fans• (3) 14 ft. (4.27m) Big Ass Fans• (5) 6 ft. (1.83m) Big Ass Fans
Hint:Place fans in your highest trafficareas and remember the maximumair flow is distributed below the tipsof the fan and spreads out from there.
If you want to move air over a workstation, place the fan so that the tipsare above the area. The best way to dothis is to hang your fans in aisleways,between several work stations.
The bottom line: Fewer fans and better coverage.
TM
PATENT PENDING
The size of the fan used isgoverned by the area to betreated. Normally, bigger isbetter. A 24 ft. (7.3m) diameterfan is a good choice in largeropen areas such as shippingor receiving docks.
When choosing a location for a fan, noteobstructions. Air fromthe fan will moveunder conveyors andthrough open racks,but will be impeded by a stack of boxes or a wall.
12ft Powerfoil™10ft Powerfoil™28 Fan Placement Example #1
Though some customers do not mind,it is relatively easy to avoid having themoving airfoil cast a shadow onto thefloor. A 12 ft. (3.6m) diameter fan will fitwithin a 10 ft.x10 ft. (3.0mx3.0m) lightinggrid with room to spare, and an 18 ft.(5.5m) diameter fan will easily fit into a15 ft. x15 ft. (4.5mx4.5m) lighting grid.(Hint: Use the Pythagorean Theorem)
The 6 ft. (1.83m) caged fan can bemounted less than 3 ft. (0.91m) from theroof deck, making it a natural choicefor mezzanines and aisleways.
Remember, a fan moves air over a 360ºarea. Locate fans at aisle intersectionsin order to optimize air movement andminimize the number of fans required.
When locating a fan over an aisle, makesure the tip of the blades are within theaisle to maximize useful air flow.
Pythagorean Theorem: a2 + b2 = c2
a
b
c
12ft Powerfoil™10ft Powerfoil™ 29Fan Placement Example #1 (cont.)
With its compact six-foot diameter and 73 unique mounting positions, the Pivot™ fan is a perfect fit for mezzanines and aisleways.
All Big Ass Fans employ airfoilsdesigned to operate at relatively lowspeeds. For example, the 24 ft. (7.3m)diameter fan moves at less than 45 rpm.
In the winter, Big Ass Fans can be usedto destratify the air in facilities. Mixingthe warm air at ceiling level with thecooler air at ground level.
Auto Service Center
Facility Specs:• 80 ft. x 160 ft. (24.39m x
48.77m) car service center• (2) 14 ft. (4.27m) Powerfoil™
Big Ass Fans
Hint:Do not be overly concerned aboutplacing the fans equi-distant fromone another. Moving a fan 10 ft.-15 ft.(3m-4.56m) out of your grid line is farbetter than locating a fan too close toa wall or in an area of limited activity.
TM
PATENT PENDING
When cars are lifted off the floorair is able to circulate underneathand keep employees nice and coolin the summer.
12ft Powerfoil™10ft Powerfoil™30 Fan Placement Example #2
12ft Powerfoil™10ft Powerfoil™34 Frequently Asked QuestionsHow much is the energy cost to operate a Big Ass Fan? QBig Ass Fans are extremely energy efficient costing less than 10 A ¢ (US) per hour to operate. In addition, by circulating the air, the fans actually save money on heating and cooling bills.
Won't the fan just bring the hotter air from the top of the building down on people? QDuring the warmer months, the fans are run at higher speeds to circulate the air within a facility. This circulation results in an even temperature Athroughout the area covered by the fans. Even though the actual temperature is not lowered, people are more comfortable because they are cooled by the breeze created by the fans.
During the cooler months, the fans are run at lower speeds to push warm air down from the ceiling to the floor without creating a cooling breeze.
Can/should we run the fans 24/7? QYes, they are used 24/7 by many of our customers. A
I can't mount my fan using the methods shown in the Big Ass Fans Installation Guide. What should I do? QIf you are not able to utilize the mounting methods shown in the manual, you should obtain the recommendations of a structural engineer before Ainstalling them. This will assure a safe installation.
What is the ideal height above the floor to hang a fan? Q(the following does not apply to the PowerfoilPlus)First, it is important to understand how a Big Ass Fan moves air. A
The fan begins by pushing air straight down to the floor. The air is then distributed over a larger area when it reaches the floor and is forced outward in all directions. When considering ideal fan height, the important thing to remember is that the lower the fan is hung, the faster its airflow will be upon reaching the floor. As a result, the airflow coverage area will be greater.
With that being said, we have many fans hung at 50+ ft (15+ m) above the floor that still provide generous airflow.
Also, keep in mind that for safety reasons, fans should not be hung lower than 10 ft (3.05 m) (when measured from airfoils).
So what is the ideal height to hang a PowerfoilPlus? QThe PowerfoilPlus behaves differently than our other fans. Along with pushing air straight down, the PowerfoilPlus also distributes air at a 45° Aangle from the tips of the airfoils. So in order to achieve maximum coverage area, PowerfoilPlus fans should be installed in larger areas and at greater distances from the floor.
How much space is required above the fan? QTo provide maximum airflow, the fan should not be placed too close to the ceiling. The minimum amount of space needed between the fan Aand the ceiling depends on the size of the fan. (note: space between fan and ceiling can include roof support structure as long as air is free to circulate). Big Ass Fans recommends the following amount of space between the fan and the ceiling:
Fan Size Space Needed Above Fan
8-12 ft 3 ft (0.9 m)*
14-18 ft 4 ft (1.2 m)*
20-24 ft 5 ft (1.5 m)**Add additional 2 ft for PowerfoilPlus™ fans.
Fans that are installed closer to the ceiling deck than the recommended distance may not achieve optimum performance.
How much clearance is needed for the Big Ass Fans foils? QAll fans must be installed to allow airfoils a minimum clearance of 2 A ’ (61 cm) away from any obstructions (lighting, cranes, sprinklers, etc).
How much does one of those things weigh? QThe weight of the fan depends upon its size and design. Our smallest fan, the Pivot, weighs 161 lbs (73 kg). Our largest fan, the 24' (7.3 m) APowerfoilPlus, weighs 330 lbs (150 kg).
12ft Powerfoil™10ft Powerfoil™ 35Frequently Asked Questions (cont.)How do I reverse the fan? QThe fans are not intended to be reversed. Just like the wings of an airplane, the fans' airfoils are designed such that they are only efficient Aturning in one direction (counter-clockwise when viewed from the floor). It is precisely this innovative design that allows Big Ass Fans to move such large volumes of air.
Instead of running the fans in different directions during the warmer and cooler months, the fans should be run at different speeds. During the warmer months, the fans should be run higher speeds to circulate air and provide a cooling breeze. During the cooler months, the fans should be run at lower speeds to push warmer air down from the ceiling to the floor without creating a cooling breeze.
When I turn the fan on it moves backwards then forward before starting to run. What's wrong? Q This is normal and does not indicate a problem. This occurs on fans with controls that feature a reversing switch. A
What supply voltage is required to power the fan? QBig Ass Fans can operate at a range of voltages that varies depending on the fan model. The majority of Big Ass Fans can operate at 100-125V A1 Phase, 200-250V 1 Phase, 200-250V 3 Phase, and 400-480V 3 Phase.
Can Big Ass Fans operate on 277 volts? QNo. 277 volt power is used exclusively for lighting. A
What are the electrical current requirements for the fan? QThe FLA (full-load amp) ratings vary depending on the size and voltage of the fan. Consult the Product Catalog or the Installation Guide Aincluded with your fan for FLA ratings.
What kind of wire should be used for the motor leads? QAlways use wire that is rated for 600V and 75 to 90 degrees C in metallic conduit. For applications not requiring shielded cable, use THHN or ATHNW. If shielded cable is necessary, RHH or RHW-2, Beldon 29501 through 29507, and Shawflex 2ACD or 3ACD are all good choices.
Why can't I use solid core wire or MC cable for the motor leads? QBecause the fan will not run satisfactorily on that kind of wire. Its characteristics are not suited to this type of use for several reasons. BAF does Anot approve the use of solid core wire or MC cable and it can affect the warranty on a fan.
Do I have to use the fan control? Why can't we just wire the fan through an on/off switch? QBig Ass Fan-supplied controls must be used with all fans. These controls do more than simply turning the fan on and changing its speed. Their Aprimary function is to protect the fan's motor and gear reducer from destructive electrical and mechanical forces. The fan controls prevent motor damage if the fan is run on a higher current than it is capable of tolerating. Likewise, the controls start and stop the fan gradually thus preventing damage to the gear reducer. These protections are required for safe fan operation and to maintain the fan's warranty.
I have a three-fan control. Is it possible to control each fan individually? QNo. Multiple fans cannot be controlled individually when connected to one fan controller. To control the fans individually, each fan would need its Aown dedicated controller.
I have a single-phase fan control, but the motor is three-phase only? Will this discrepancy cause a problem? QNo. The fan control is able to convert single-phase input to three-phase output. A
Why are the motors set up for 460-volts when I ordered 230-volt controls? QThey are tested by the manufacturer using 460-volts so they are left in that configuration. When 230-volt or 115-volt controls are used, the Amotors must be re configured for 230-volt operation. This should only take about five minutes.
I ordered my fan with 460-volt controls but have found that I don't have 460-volt service where the fan will be installed. What can you Qdo?It is always best to make sure that the control you are ordering is compatible with the available power near the intended location for the fan. We Acan exchange controls but apply a restocking charge and freight charges. Exchanging the fan controls is likely to delay the installation.
We have a problem with employees changing the fan's speed setting. Is there a way to limit access to the controls? QYes. We offer lockable covers for the fan controller™s rotary on/off switch and speed potentiometer. These covers limit access of the fan controls Ato those in possession of a key.
12ft Powerfoil™10ft Powerfoil™36 Frequently Asked Questions (cont.)Should we use the red and yellow main power switch to turn the fan on and off? QNO. The black two or three position switch MUST be used for the normal on and off function. Using the red and yellow main power switch for Anormal on and off functions will quickly cause severe damage to the fan.
Can I feed multiple fan controls from one branch circuit? QYes, as long as that circuit is sized correctly. Each fan control is internally fused and the circuit must be sized for the total of the individual Ainternal fuses. For example, three fan controls, each of which has internal fusing at 10 amps, must be on a 30 amp circuit.
Can we interface the fan with our fire suppression system? QYes. Big Ass Fans can provide a schematic showing the correct way to interface the fan with the fire suppression system. Big Ass Fans are also Aavailable with VESDA® (Very Early Warning Smoke Detection Apparatus) by Xtralis®. VESDA works with the fan by detecting smoke at the earliest stages of a fire, and then sending a signal to automatically shut down the fan.
What kind of maintenance is recommended for the fans? QBig Ass Fans require very little maintenance. The annual maintenance inspection includes retorquing all fasteners, checking for missing or Adamaged components, inspecting wiring connections, and dusting the fan and controller. For more information, see the Installation Guide included with your fan.
Do I need to change the oil in the gear reducer? QNo. Servicing the gear reducer with lubricating oil is not required. It is designed to last for life. A