Advancing Ventilation DamperFlyer-0918 September 2018 Backdraft and Motorized For Residential and Commercial Use Dampers CAR MD MD6-ES24VK MCA • ES24V
2

Backdraft and Motorized Dampers - HVACQuick · Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for

Oct 02, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Backdraft and Motorized Dampers - HVACQuick · Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for

Advancing VentilationDamperFlyer-0918September 2018

Backdraft and Motorized

For Residential and Commercial UseDampers

CAR • MD • MD6-ES24VK • MCA • ES24V

Page 2: Backdraft and Motorized Dampers - HVACQuick · Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for

S&P USA Ventilation Systems, LLC | 6393 Powers Avenue, Jacksonville, FL 32217, USA | 1-800-961-7370S&P Canada Ventilation Products, INC | 6710 Maritz Drive, Unit 7, Mississauga, ON L5W 0A1, Canada | 1-866-733-0233

http://www.solerpalau-usa.com | http://www.solerpalaucanada.com

Social icon

SquareOnly use blue and/or white.

For more details check out ourBrand Guidelines.

MD6-ES24VK - Motorized DamperThe MD6-ES24VK fresh air kit from S&P allows fresh air to enter dwellings to meet building code and ventilation standards requirements through a 6” motorized damper controlled by a 24V temperature/humidity monitoring control. The control can command the central HVAC blower to help distribute the fresh air through the existing ductwork if necessary.

MCA - Back Draft DamperFits over the TD lip and is mounted on outlet side. The shutter prevents the air re-circulating when the fan(s) are not in use. Available in sizes 4” through 12.4”.

MD - Motorized DamperThis normally closed, power open, 24V or 120V motorized damper for round ducts can be used to control the sequencing of outside air in forced-air systems. Available in sizes 4” through 14”.

ES24V - Envirosense Ventilation ControlThe ES24V control can be used with our RF-reFresh, TD-MIXVENT, TD-SILENT, PV-POWERVENT, or TR-ERVs. When paired with S&P fans the ES24V provides fully controllable fresh air into a residence. With three modes (Off, On, and Eco-Mode) the ES24V ensures compliance with today’s outside air codes.

1-3/16” 1-5/8”3-1/4”

3/8”

Ø 3

/16”

CAR - Back Draft DamperBackdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure. Available in sizes 4” through 16”.