Top Banner
b d N IAL Kenmore Dehumidifier Read this book[ It will tell you how to use and care for... get the most out of...your dehumidifier. Part Number 91SD-DOI
8

b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

Jun 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

b d N IALKenmore Dehumidifier

Read this book[ It will tell you how to use and care for...get the most out of...your dehumidifier.

Part Number 91SD-DOI

Page 2: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

Jl/ll I I i i IIII"IL'JL 'l 'll'

PLEASE READ THIS OWNER'S MANOAL BEFORE YOU DO ANYTHING ELSE.

This booklet tells you how to install your dehumidifier, use it and clean it. Treat your new dehumidifier with care.

Use it only to do what home dehumidifiers are designed to don

Contents

Parts and Features... PageParts Identification .......................... 2

Features ................................. 3

Before Using Dehumidifier...Electrical Requirements ............... 3Grounding Instructions ................... 3"Don'ts" to Remember ................... 3

Operation...Installation ........................... 4

PageFeatures and How to Use Them ......... 5,6

Care and Upkeep...

Troubleshooting ........................ 7

Cleaning Your Dehumidifier .............. 7

Warranty and Parts OrderingInformation ............. Back Cover

I PARTS AND FEATURES

CONTROLPANEL

IEVAPORATOR COIL

HUMIDISTAT

WATER BUCKET

FAN _\\FULL LIGHT

FRONT GRILLE

MODEL AND SERIALNUMBER PLATE

(Behind Bucket)

\

COPY YOUR MODEL AND SERIAL NUMBERS HERE...

If you need service or call with a question, have

this information ready:

1. Complete Model and Serial Numbers (from the

plate on the rear of the unit, behind the water

bucket,,)

2. Purchase date from the sales slipo

Copy this information in these spaces,, Keep thisbook, with warranty and sales slip together in a

handy place.

Model Number

Serial Number

Purchase Date

/,

Phone Numbers: Service Center/Store

Page 3: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

FEATURESCheckthischart for yourdehumidifierfeatures.

Pintsof water removed each 24 hours*

Full Bucket Signal Light

Automatic ShutOff Switch

Automatic Humidistat

De-icer Control

Fan Control Switch

Removable Water Collection Bucket

*The moisture-removing ability of Sears dehumidifiers is certified in accordance

Standard B-149-1 (AHAM DH-1) at 80°F and 60% relative humidity.

Model Number

5941

40

Yes

Yes

Yes

Yes

Yes

Yes

with American National

i BEFORE USING DEHUMIDIFIER IF' ELE,€ RICALREQUIREMENTS..........i I ,,, "DON'TS" TO REMEMBER_ I

A ll5-volt (103o5 min., 126.5 max..), 60-hertz,

AC only, 15-ampere fl_sed electrical supply is

needed (use time delay fuse or time delay circuit

breaker)° Use a separate circuit, serving only this

appliance° Do not use an extension cord_

I " GROUNDING INSTRUCTIONS. .......... 1

OBSERVE ALL LOCAL GOVERNING CODES

AND ORDINANCES

Do not, under any circumstances, remove the

power supply cord ground prong.

For your personal safety, this appliance must be

grounded_ This appliance has a power supply cord

with a 3-prong grounding plug_ To avoid possibleshock hazard, the cord must be plugged into a

mating 3-prong grounding type wall receptacle,

grounded in accordance with the National Electri-cal Code and local codes and ordinances. If a mat-

ing wall outlet is not available, it is your

responsibility and obligation to have a properly

grounded 3-prong wall receptacle installed by a

qualified electrician_

1,_Don't alter or change the plug on the power

supply cord of your dehumidifier. Changes wouldmake it unsafe, could cause serious damage to the

dehumidifier, and might void the warranty,

3-PRONGGROUNDING TYPEWALL RECEPTACLE

/ 3_PRONGGROUNDING PLUG

POWER SU PPLYCORD

2o Don't try to use this dehumidifier on direct cur-

rent (D.C_)o Make sure the receptacle is wired to

a 60 hertz alternating current of 1 t 5 volts and

15 ampso3. Don't use an extension cord,

4_ Don't use a circuit that will become overloaded

when dehumidifier is installed°

5. Don't plug in the dehumidifier if you're in doubt

about the grounding of your electrical system.

Consult a qualified electrician first.6_ Do not remove tech sheet which is inside

the cabinet. Your service technician needs this

information°

3

Page 4: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

OPERATION

! INSTALLATION.

! WARNING: Do not use Dehumidifier near

flammables, such as gasoline.

Your Kenmore dehumidifier can be placed

almost anywhere, depending on the water disposalmethod°o Place the dehumidifier at least six inches from

the wall; don't place it in a corner or near a large

piece of furniture_• Shut all doors and windows in the area to be

dehumidified.o Before installation allow the unit to warm to

room temperature before operating

• For the first few days, on models with a humidi-stat, turn the humidistat to "constant" to remove

extra moisture from the furnishings as well as from

the room air. When the area has dried, change thehumidistat to a lower number,

Your dehumidifier may be placed on a table or

shelf that is strong enough to support it with a full

bucket of water (see below)_ A shelf or table may

be a better position to handle the water bucket

or to adjust controls Do not sit or stand on this

product,

)

IAlso the height of a table or shelf may help pre_

vent icing of the coils due to colder air near the

floor (such as can be found in a basement)_

Don't block either end or right side of the dehu-midifier_ The dehumidifier takes air from the back

and blows it out from the front and side. So wher*

ever you place it, be sure there's enough room for

good air movement and water bucket removal°

Your dehumidifier can be operated in an out-of-

the_way area such as a utility room and still effec-

tively dry out adjoining areas (see below). However,

it is helpful to leave doors open between theseareas so the moisture in the air can move from

room to room.

A TYPICAL BASEMENT

!

CAUTION: Dehumidifier will not work

properly at temperatures below 65°F (55°F

for models with de-icer control).

4

The coil of any dehumidifier can become blocked

with ice in room temperatures below 65 degrees. Ice

buildup on the coil stops the air flow from the dehu-

midifier and it stops dehumidifying even though itkeeps running°

Generally your furnace heat also warms the base-

ment evenly to keep the temperature above 65 ° ,

The problem usually starts when on warm Spring or

Autumn days the basement doesn't receive warmed

air and may be at temperatures below 65 ° , espe-

cially at floor level° If icing should occur, unplug

unit (or turn it off) until ice melts and room temper-

ature is above 65 °, Models with de-icer control (see

page 5) perform this action for you, Lifting the

dehumidifier off of the floor may help because that

places it in warmer air

Page 5: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

J FEATURES AND HOW TO USE THEM

CONTROL PANEL

I FAN CONTROL,.

This controls fan operation of the dehumidifier.

When the humidistat calls for dryer air, the com-

pressor and fan motor will run until the humidistat

setting is satisfied_ Use HI for faster air drying and

LO for quieter operation°

AUTOMATIC SHUTOFE

The automatic shutoff switch turns off the dehu-

midifier when the water bucket is filled to its preset

level To restart dehumidifier, simply remove water

bucket, empty and rehang it on the back of the unit°

HUMIDISTAT.

To adjust the humidistat control turn the knob to

the setting you prefer_

Constant.

If you choose this setting, dehumidifier wilt run all

the time no matter what the humidity might be.

! thru 6 plus Constant.

This is the range of relative humidity on the humidi-

star control knob_ "Youmay adjust the humidistat

setting higher or lower to suit your needs° Higher

numbers make air dryer; lower numbers leave more

moisture in the air_ When the relative humidity is

reduced to the level you have chosen, the dehumidi-

tier will turn itself off° It will turn itself on again

when the humidity risesOff.

This setting turns the dehumidifier off when the

dehumidifier is not needed

NOTE: If you turn your dehumidifier off and turn

it right on again, the compressor may try to start

then stop. This is normal. In about two minutes, the

compressor will start again and continue to run_

SIGNAL LIGHT.

The signal light warns when water bucket is full

for emptying and the dehumidifier has stopped Be

sure to replace bucket properly so unit will run°

DE-ICER CONTROL,

Your Kenmore dehumidifier is equipped with a

feature to help you get the most comfort from your

new appliance by permitting it to operate down to55OE

If your dehumidifier runs when room temperature

and humidity conditions are low, frost can form on

its evaporator coil. This interferes with proper

operation.

The DE-ICER control senses frost build-up on the

evaporator coil and automatically shuts off the com-

pressor. The fan continues to run, drawing air across

the coil and melting the frost. When the coil isdefrosted, the DE-ICER control restarts the com-

pressor automatically and dehumidifying isresumed.

Before installation, allow the unit to warm to

room temperature before operating It may not start

if temperature is below 55°E

5

Page 6: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

WATER COLLECTION BUCKET

Your dehumidifier was supplied with a sturdy

bucket which hangs conveniently on the back ofthe unit to accumulate water removed from the air,.

The Shut Off Switch (A) is activated by a float

and:

1_ Stops the unit before the bucket fills to

overflowing.2_ Turns the unit on again after the bucket is emp-

tied and replaced.

tf you want the water to flow directly to a drain,

connect any standard garden hose to the bucket

connection (B) or place the dehumidifier over thedrain._

Note: a standard garden hose has a ¾" diameter

connection with 11 _ threads per inch. Be sure thehose lies flat, not kinked. A drain hose may be

bought from Sears, Part No° 9181_

When using either of these direct draining meth-

ods, break through the plastic membrane in the

bucket connection (B),. Peel away any remainder so

the opening will be clear and permit water to flow

freely_

To reseal the hose connection on the bucket, use

any standard hose end cap.,

6

Page 7: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

CARE AND UPKEEP

............................. i i

WARNING: SHOCK OR INJURY HAZARD

before servicing be sure to unplug power cordfrom outlet. Handle the Dehumidifier with care.

Watch out for the sharp metal surface and fins on

the inner coil.

CLEANING THE COILS INSIDE THE

DEHUMIDIFIER.

The refrigerant coils are al! that need cleaning

on the inside of your dehumidifier_ For the best effi-

ciency, clean the coils well at least once a year

(more often if needed) with a brush or vacuumcleaner° Also, clean the drain hole and the connect-

ing drain hose, if used.

i ...............

TROUBLESHOOTING

IF DEHUMIDIFIER STOPS RUNNING.

1. See if power cord is plugged in properly and unitis turned ono

2_ Check the power supply to be sure the outlet

works. Plug in a lamp_3_ Check for a blown fuse or tripped circuit breaker.

Never overload a circuit

4. Check water bucket to see if it is installed prop-

erly or needs emptying_IF IT RUNS BUT DOESN'T DEHUMIDIFY

Unit may be in defrost cycle due to frost build-upon coil. Unit will restart as soon as frost is melted

off and temperature rises above 55°F

IF DEHUMIDIFIER STILL DOES NOT RUN RIGHT.

Call your nearest Sears Service Center_ Sears

technicians are specifically trained to do the work.

When you call, give them the complete model andserial number You'll find the information on a metal

plate located in the rear beneath the drain buckeL

CLEANING YOUR DEHUMIDIFIER.

o Be sure to read the owner's manual and follow its

instructions°

o Always unplug the power cord before cleaning a

dehumidifier. Dust the grilles or louvers with a soft

brush or the dusting attachment of your vacuumcleaner.

o Every few weeks wash the inside of the water con-

tainer with a sponge or soft cloth and a mild deter-

gent to prevent the growth of mold, mildew andbacteria.° Once or twice each season remove dust and lint

from the cold coils with a soft brush.

o To clean dehumidifier cabinet, wash with warm,

mitd sudsy water° Rinse with clear water and drywith a soft cloth° Never use solvents, cleaning fluids,

abrasive cleaners or strong detergents_ CAUTION:Don't turn dehumidifier on until outside is com-

pletely dry.

. if outside paint chips or is damaged, you can

touch up the outside of the cabinet with a good

grade of enamel paint to prevent rusL

7

Page 8: b d N IAL - Sears Parts Directconnection with 11 _ threads per inch. Be sure the hose lies flat, not kinked. A drain hose may be bought from Sears, Part No° 9181_ When using either

Kenmore Ordering Information.

We service what we sell,"We Service What We Sell" is our assurance to you that you can depend on Sears for service, and Sears service is

nationwide.

Your dehumidifier has added value, when you consider that Sears-trained technicians .... professional techni-

cians specifically trained on Sears appliances, having the parts, tools and equipment to ensure that we meet our

pledge to you. °. "We Service What We Sell:'

To further add to the value of your Dehumidifier.Buy a Sears maintenance agreement.

Sears appliances are designed, manufactured and tested for years of dependable operation. Yet, any modernappliance may require service from time to time,. The Sears warranty plus the Sears maintenance agreement pro-

vides protection from unexpected repair bills.

Contact your Sears sales person or local Sears Service Center today for information on a Sears maintenance

agreement.

_MMMMM_fl-MMMMC.-_MC_M_MMMMMI_MMMMMMM

_H_HMHI?iI6_M_IM_H_M_HMM_MMM_M(__ M_,_i_ M_ MMMM_OMMM_M M_ _M MMMMM_ MMMC_

SEARS, ROEBUCK AND CO., Dept. 698/731 A, Sears Tower, Chicago, IL 60684 Printed in tts ^.