Top Banner
B. Braun Vascular Systems Cardiology and Radiology Catalogue Solution Oriented Angioplasty
42

B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Aug 11, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

B. Braun Vascular SystemsCardiology and Radiology

Catalogue

Solution Oriented Angioplasty

Page 2: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Solution Oriented Angioplasty

A total line of highly effective & safe productsto cover individual patient needs.

Page 3: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Vascular Systems

Products for Cardiology and Radiology

Product field Product group Product Page

CARDIOLOGYCoronary Angioplasty Coronary Stent System CSS Coroflex 3

Cobalt Chromium CSS Coroflex Blue 4/5Paclitaxel-Releasing CSS Coroflex Please 6/7

Paclitaxel-Releasing PTCA Balloon Catheter SeQuent Please 8/9

PTCA Balloon Catheter SeQuent ll 10/11

Coronary Guide Wire Navitas Plus 12

Accessories for PTCA Intradyn PTCA 13Metal insertion tool 13Inflation devices for PTCA 14Torquer 14Y-Connector 15Kissing BiBalloon adapter 15PTCA Kits 15Bifurcation Kit 15Fluid collection system 15

Coronary Angiography Angiographic Catheter Diagnostic Catheter for Angiography 16/17/18

Angiodyn Procedure Kits + Service Customized Service 19Standard Kits 20

Angiographic Accessories Angiodyn Guide wires 21Angiodyn High pressure full-body manifolds 22Angiodyn Mid pressure half-body manifolds 23Angiodyn High pressure tubing 24Angiodyn Spectraline syringes 25Angiodyn Contrast saver system 25Angiodyn Contrast saver tubing 25Angiodyn Angiographic syringes 26Angiodyn Injector syringes 26Angiodyn Image intensifier covers and bags 27

Catheter Introducer Sheath Introducer Intradyn Arterial 28(Seldinger technique acc. Tear Away Introducer Intradyn Tear-Away 29to Desilets-Hofmann)

Heart Stimulation Stimulation Probe Eledyn, Eledyn Add-on Kits 30Eledyn 2/FX 31

RADIOLOGYPeripheral Angioplasty Peripheral Stent System VascuFlex SE 32/33/34

Carotid and Peripheral Stent System VascuFlex SEC 35/36

Vena Cava Filters Permanent Filter VenaTech™ LGM 30 D/U 37VenaTech™ LP 37VenaTech LP Brachial Introducer System 37VenaTech LP Platinum Introducer System 37

Temporary Filter Tempofilter II 37Convertible Filter VenaTech™ Convertible 37

Conversion Table 38

Page 4: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

2

Coroflex

Coronary Stent System

CoroflexHighest flexibility and lowest profile for complex cases.

On the basis of pliable connection bridges, the proven design of the Coroflex stent provides excellent bending characteristics for a balloon-like handling and superb vessel conformability for a reliable treatment of any lesion.

• Stent – Excellent perfomance in bifurcations— material: stainless steel 316L— highest flexibility to navigate through tortuous vessels and

to cross difficult lesions— ultra low foreshortening and stent recoil < 3% due to mid-point

connection of the sinus ring elements— outstanding side branch accessability (crossable cell

diameter 0.9 - 1.3 mm)

— low profile:

Ø 2.5 mm 0.037’’Ø 3.0 mm 0.037’’Ø 3.5 mm 0.038’’Ø 4.0 mm 0.040’’

• Delivery System— Rapid Exchange System

Page 5: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

3

Code-Number

Salesunit-pcs.

Coroflex

Coronary Stent System

8 mm 2.5 6 15 5020040 13.0 6 15 5020141 13.5 6 15 5020142 14.0 6 12 5020143 1

13 mm 2.5 6 15 5020176 13.0 6 15 5020177 13.5 6 15 5020178 14.0 6 12 5020179 1

16 mm 2.5 6 15 5020113 13.0 6 15 5020114 13.5 6 15 5020103 14.0 6 12 5020104 1

19 mm 2.5 6 15 5021900 13.0 6 15 5021911 13.5 6 15 5021922 14.0 6 12 5021933 1

25 mm 2.5 6 15 5020194 13.0 6 15 5020191 13.5 6 15 5020192 14.0 6 12 5020193 1

Nominal Pressure(atm)

Stent Diameter(mm)

Stent Length

• Coroflex Order Information

Rated Burst Pressure (atm)

Page 6: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Coroflex Blue

Cobalt Chromium Coronary Stent System

Coroflex BlueThe outstanding material characteristics of cobalt-chromium alloy combined with the advanced SeQuent catheter technology guarantee an excellent approach and a reliable crossing of complex anatomies.

• Stent— material: cobalt – chromium alloy L605— ultra-thin strut thickness of only 65 µm (0.0026’’)— superb system performance in flexibility and deliverability— balloon overhang of less than 0.5 mm on each side of the stent— unique vessel wall conformability— enhanced radiopacity and high radial strength— proven biocompatibility and safety— ideal for direct stenting— outstanding side branch accessibility

(crossable cell diameter 0.9 - 1.3 mm)

— lowest profile:

Ø 2.5 mm 0.034’’Ø 2.75 mm 0.035’’Ø 3.0 mm 0.036’’Ø 3.25 mm 0.037’’Ø 3.5 mm 0.037’’Ø 4.0 mm 0.038’’

• Delivery System— based on SeQuent® Rapid Exchange PTCA catheter technology

4

Page 7: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

5

Code-Number

Salesunit-pcs.

Coroflex Blue

Cobalt Chromium Coronary Stent System

8 mm 2.5 10 15 5025003 12.75 10 15 5025004 13.0 10 15 5025005 13.25 10 15 5025006 13.5 10 15 5025007 14.0 10 12 5025008 1

13 mm 2.5 10 15 5025013 12.75 10 15 5025014 13.0 10 15 5025015 13.25 10 15 5025016 13.5 10 15 5025017 14.0 10 12 5025018 1

16 mm 2.5 10 15 5025023 12.75 10 15 5025024 13.0 10 15 5025025 13.25 10 15 5025026 13.5 10 15 5025027 14.0 10 12 5025028 1

19 mm 2.5 10 15 5025033 12.75 10 15 5025034 13.0 10 15 5025035 13.25 10 15 5025036 13.5 10 15 5025037 14.0 10 12 5025038 1

25 mm 2.5 10 15 5025043 12.75 10 15 5025044 13.0 10 15 5025045 13.25 10 15 5025046 13.5 10 15 5025047 14.0 10 12 5025048 1

28 mm 2.5 10 15 5025153 13.0 10 15 5025155 13.5 10 15 5025157 14.0 10 12 5025158 1

33 mm 2.5 10 15 5025163 13.0 10 15 5025165 13.5 10 15 5025167 14.0 10 12 5025168 1

Nominal Pressure(atm)

Stent Diameter(mm)

Stent Length Rated Burst Pressure (atm)

• Coroflex Blue Order Information

Page 8: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

6

Coroflex PleaseSuperior flexibility and proven drug release.

• Effective anti-proliferative drug: PaclitaxelNumerous studies demonstrated the positive effects of paclitaxel oninhibiting Smooth Muscle Cell (SMC) proliferation and migration.

• Highly flexible Coronary Stent SystemCoroflex Please offers excellent mechanical properties and a high system flexibility designed for optimal stent deliverability and deployment.

• Superior Coating TechnologyA state of the art coating technology assures a consistent, controlleddrug delivery and facilitates the surface integrity during stent implantation.

• Rapid Exchange System

Coroflex Please

Paclitaxel-Releasing Coronary Stent System

Page 9: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

7

Code-Number

Salesunit-pcs.

Coroflex Please

Paclitaxel-Releasing Coronary Stent System

8 mm 2.5 10 15 5024400 12.75 10 15 5024404 13.0 10 15 5024401 13.5 10 15 5024402 14.0 10 12 5024403 1

13 mm 2.5 10 15 5024410 12.75 10 15 5024415 13.0 10 15 5024411 13.5 10 15 5024412 14.0 10 12 5024413 1

16 mm 2.5 10 15 5024420 12.75 10 15 5024424 13.0 10 15 5024421 13.5 10 15 5024422 14.0 10 12 5024423 1

19 mm 2.5 10 15 5024430 12.75 10 15 5024434 13.0 10 15 5024431 13.5 10 15 5024432 14.0 10 12 5024433 1

25 mm 2.5 10 15 5024440 12.75 10 15 5024444 13.0 10 15 5024441 13.5 10 15 5024442 14.0 10 12 5024443 1

28 mm 2.5 10 15 5024450 12.75 10 15 5024454 13.0 10 15 5024451 13.5 10 15 5024452 14.0 10 12 5024453 1

32 mm 2.5 10 15 5024460 12.75 10 15 5024464 13.0 10 15 5024461 13.5 10 15 5024462 14.0 10 12 5024463 1

Nominal Pressure(atm)

Stent Diameter(mm)

Stent Length

• Coroflex Please Order Information

Rated Burst Pressure (atm)

Page 10: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

8

SeQuent PleaseA novel concept of targeted, polymer-free and homogenous drug delivery designed to overcome the limitations of today’s treatment options. Clinically proven, it offers completely new procedural solutionscombined with a higher safety profile and superior efficacy.

• Superior clinical patient outcomes in complex lesions– In-stent restenosis (ISR) – Small vessel disease (SVD)

• Advanced interventional options for the most challenging cases,e.g.

– Chronic Total Occlusion (CTO)– Bifurcations– Diabetic patients– Long lesions

• Advantages and benefits– Maximum lesion accessibility due to a PTCA balloon-like handling– Single shot, short-term Paclitaxel delivery for long-term vessel

patency– Targeted drug delivery into the vascular wall– Bio-absorbable, polymer-free drug coating for the prevention of side

effects– Homogenous and pattern free drug distribution– No stent related edge effects– No need for stent-in-stent procedures – Unlimited treatment options in case of patients’ re-intervention– Reduced duration of antiplatelet therapy – Single treatment or in combination with a bare metal stent (BMS)

SeQuent Please

Paclitaxel-Releasing PTCA Balloon Catheter

Page 11: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

10 mm 2.5 0.026 7 15 5022200 13.0 0.026 7 15 5022201 13.5 0.027 7 15 5022202 14.0 0.027 7 12 5022204 1

15 mm 2.0 0.025 7 12 5022205 12.5 0.026 7 15 5022206 12.75 0.026 7 15 5022207 13.0 0.026 7 15 5022208 13.5 0.027 7 15 5022210 14.0 0.027 7 12 5022211 1

17 mm 2.0 0.025 7 12 5022212 12.5 0.026 7 15 5022213 12.75 0.026 7 15 5022214 13.0 0.026 7 15 5022215 13.5 0.027 7 15 5022218 14.0 0.027 7 12 5022219 1

20 mm 2.0 0.025 7 12 5022220 12.5 0.026 7 15 5022221 12.75 0.026 7 15 5022222 13.0 0.026 7 15 5022223 13.5 0.027 7 15 5022225 14.0 0.027 7 12 5022227 1

26 mm 2.5 0.026 7 15 5022230 12.75 0.026 7 15 5022231 13.0 0.026 7 15 5022232 13.5 0.027 7 15 5022234 1

30 mm 2.5 0.026 7 15 5022240 13.0 0.026 7 15 5022242 13.5 0.027 7 15 5022243 1

Balloon Profile (inch)

Balloon Diameter (mm)

Balloon Length

Rated BurstPressure(atm)

NominalPressure(atm)

• SeQuent Please Order Information

9

Code-Number

Salesunit-pcs.

SeQuent Please

Paclitaxel-Releasing PTCA Balloon Catheter

Delivery System Rapid ExchangeProximal shaft 1.8 F Hypotube stainless steel, coatedDistal shaft 2.5 F PolyamideUsable length 138 cmBrachial & femoral marker 90 cm & 100 cmGuiding catheter compatibility 5 FGuidewire compatibility 0.014“Tip profile 0.017”Balloon compliance Semi compliant standard balloons

Page 12: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

SeQuent ll

PTCA Balloon Catheter

SeQuent llThe conSeQuent device evolution. Elaborated balloon catheter technology for percutaneous transluminal coronary angioplasty

• State of the art crossability– sequential tip (hard-soft tip) to pass the most challenging lesions– extremely downsized tip profile of only 0.016’’ – COMAX® balloon material for superb flexibility and deliverability – "Zero profile" x-ray markers for minimal crossing profile– improved taper geometry– further improved balloon folding and profile

• Excellent accessability/pushability/trackability– 1.9F hypotube shaft design for enhanced catheter advancement– highly flexible 2.5F distal shaft – 5F guiding catheter compatible

• True 6 F "kissing" balloon capability– re-designed guidewire exit

• Optimized sequential tip proportions– elongated highly flexible zone for guidewire trackability and

lesion crossing– shortened and futhur downsized robust tip for calcified

lesions and recrossing

• Best torque & push– innovation awarded shaft material with highest available

kink resistance

SeQuent CTOThis SeQuent catheter is especially designed for the treatment of tightand small lesions (total occlusions)

– balloon diameters of 1.25 and 1.5 mm (L 10 to 20 mm)– advanced balloon flexibility due to a reduced wall thickness

10

Page 13: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

SeQuent ll

PTCA Balloon Catheter

10 mm 2.0 0.025 6 15 5021421 12.25 0.025 6 15 5021422 12.5 0.026 6 15 5021423 12.75 0.026 6 15 5021424 13.0 0.026 6 15 5021425 13.5 0.026 6 15 5021427 14.0 0.026 6 12 5021429 1

15 mm 2.0 0.025 6 15 5021431 12.25 0.025 6 15 5021432 12.5 0.026 6 15 5021433 12.75 0.026 6 15 5021434 13.0 0.026 6 15 5021435 13.5 0.026 6 15 5021437 14.0 0.026 6 12 5021439 1

20 mm 1.25 CTO 0.024 10 18 5021480* 11.5 CTO 0.024 10 18 5021440* 12.0 0.025 6 15 5021441 12.25 0.025 6 15 5021442 12.5 0.026 6 15 5021443 12.75 0.026 6 15 5021444 13.0 0.026 6 15 5021445 13.5 0.026 6 15 5021447 14.0 0.026 6 12 5021449 1

25 mm 2.0 0.025 6 15 5021451 12.25 0.025 6 15 5021452 12.5 0.026 6 15 5021452 12.75 0.026 6 15 5021454 13.0 0.026 6 15 5021455 13.5 0.026 6 15 5021457 14.0 0.026 6 12 5021459 1

30 mm 2.0 0.025 6 15 5021461 12.25 0.025 6 15 5021462 12.5 0.026 6 15 5021463 12.75 0.026 6 15 5021464 13.0 0.026 6 15 5021465 13.5 0.026 6 15 5021467 14.0 0.026 6 12 5021469 1

Rated burstpressure (atm)

Balloon Diameter (mm)

Balloon Length

Nominal pressure (atm)

Balloon Profile

(inch)

• SeQuent II Order Information

11

Code-Number

Salesunit-pcs.

* 1.25 and 1.5 CTO balloons with 1 centered marker band.

Delivery System Rapid ExchangeProximal shaft 1.9 F Hypotube stainless steel, coatedDistal shaft 2.5 F PolyamideUsable length 145 cmBrachial & femoral marker 90 cm & 100 cmGuiding catheter compatibility 5 F / "Kissing“ balloon: 6 FGuidewire compatibility 0.014“Tip profile 0.016”Balloon compliance Semi compliant standard balloons

Non compliant 1.25 mm & 1.5 mm balloons

Page 14: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

12

Code-Number

Salesunit-pcs.

Navitas Plus

Coronary Guide Wires

Navitas PlusCoronary guide wire for placement and stabilizing of PTCA catheters andstent systems

– excellent torquability and kinking stability due to single core wiretechnology

– optimal shaping and memory within the distal area because of a flat core wire section

– combination of radiopacity (3 cm distally) and radiolucency (27 cm medially)

– special coating over the distal 30 cm facilitates catheter system trackability, smooth wire movement and gliding performance

– 7 different flexibilities and an extension wire for different applications

Navitas EW (Extension Wire) 150 0.014’’ 5050005 5

Ø inchlength (cm)product description

Extension wire

– extends the Navitas Plus guide wire to approx. 345 cm– compatible to all Navitas and Navitas Plus guide wires

Navitas Plus, Extra Floppy, hydrophilic, straight 195 0.014’’ 600-000-010 5Navitas Plus, Floppy, hydrophilic, straight 195 0.014’ 601-000-010 5Navitas Plus, Floppy J, hydrophilic, J-Tip 195 0.014’’ 601-001-010 5Navitas Plus, Intermediate, hydrophilic, straight 195 0.014’’ 602-000-010 5Navitas Plus, Standard, hydrophilic, straight 195 0.014’’ 603-000-010 5Navitas Plus, Floppy/Extra Support, hydrophilic 195 0.014’’ 601-100-010 5Navitas Plus, 3gf, hydrophilic, CTO, straight 195 0.014’’ 100-000-001 5

Ø inchlength (cm)product description

Standard guide wires

Please ask your B. Braun clinical specialist for further configurations.

Page 15: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

13

Code-Number

Salesunit-pcs.

Accessories for PTCA

Introducer, Inflation Device etc.

colourlength (mm)gauge

20 75 transparent 5017826 20

Metal insert tool

Intradyn PTCA F8 blue 5215161 5

Intradyn PTCA Introducer for Percutaneous Transluminal Coronary Angioplasty

• Sheath 230 mm made of FEP– with hemostasis valve – side port with three-way stopcock– flexible collar and suture hub• Dilatator, 280 mm made of PE– atraumatic tip– Luer Lock connection between sheath and dilatator

Page 16: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

14

Code-Number

Salesunit-pcs.

Accessories for PTCA

Introducer, Inflation Device etc.

Torque device 5023687 10

TorquerTorque device for guide wires

– luminescent– wire grip for all diameters up to 0.022"

Inflation Device for PTCA, 25 ml / 30 atm 622510 1

Inflation Device for PTCA– easy handling by winged locking mechanism– angled, luminous pressure gauge – precise inflation, quick deflation– crystal clear barrel for easy debubbling– 30 cm high pressure tubing with three-way stopcock

and rotating adaptor

Inflation Device for PTCA, 20 ml / 30 atm 5028900 1

Inflation Device for PTCAPressure gauge:– 90° rotating manometer for “custom” handling– coded figures from nominal to burst pressures for easy reading

Body and button:– unique mechanism for rapid pressure increase, i.e. effective and fast

procedures– grip design for better handling– clear material for easy air bubble detection and removal

Handle:– ergonomic design for optimal handling– progressive resistance while inflating for pressure feedback

Page 17: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

15

Fluid Collection System 5010555 50

Code-Number

Salesunit-pcs.

Accessories for PTCA

Y-Connector, PTCA-Set, Fluid Collection System

PTCA-Kit 2 5028550 10

PTCA-Kit 2– Y-connector with metal insertion tool– Torquer, luminescent wire grip for all diameters up to 0.022"

Bifurcation Kit 5028904 1

Bifurcation Kit– Inflation device– Double Y-Connector– Kissing Balloon adaptor– Insertion tool and torquer

Kissing BiBalloon adaptor 5014760 25

Unique Kissing BiBalloon adaptorFor simultaneous and/or sequential dilatation of bifurcation lesions- innovative approach for multiple dilatation techniques- final kissing balloon inflation

PTCA-Kit 1 622511 1

PTCA-Kit 1– Y-connector with metal insertion tool– Torquer, luminescent wire grip for all diameters up to 0.022"– Inflation Device for PTCA (622510)

Y-connector with plastic insertion tool 5021693 10Double Y-connector with plastic insertion tool 5020743 5

Y-ConnectorFor all interventional techniques

– with rotational adaptor and Touhy-Borst-valve– 9.5F lumen

Customized kits on request. Please ask your B. Braun clinical specialist.

Fluid Collection System — aspiration of liquids (saline solution, contrast media)— secure disposal of aspiration liquid in a closed container (bag)— tubing length to dual check valve: 190 cm— tubing length to container: 180 cm— container volume: 1000 ml

Page 18: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

16

Angiographic Catheter

Diagnostic Catheter for Angiography

Diagnostic Catheters for Angiography

• Superior Torque- maximal control and 1:1 force transmission due to symmetrically

braided shaft - save and enhanced handling supported by ergonomic hub- facilitated identification due to colour coded French sizes

• Excellent Push- optimal push and kink resistance- gentle navigation due to ultimate tip flexibility- atraumatic rounded distal tip design- soft tip on all selective models

• Best Flow- easy injection, superior flow rates and high quality angiographic

results thanks to large inner lumen- catheter stability during injection

4 French (red)Selective Pigtail

Outer Diameter Body & Tip 0.055”/ 1.39 mm 0.055”/ 1.39 mmInner Diameter Body 0.042”/ 1.07 mm 0.042”/ 1.07 mmInner Diameter Tip 0.042”/ 1.07 mm 0.042”/ 1.07 mm

5 French (grey)Selective Pigtail

Outer Diameter Body & Tip 0.065”/ 1.67 mm 0.065”/ 1.67 mmInner Diameter Body 0.050”/ 1.27 mm 0.050”/ 1.27 mmInner Diameter Tip 0.047”/ 1.18 mm 0.042”/ 1.06 mm

6 French (green)Selective Pigtail

Outer Diameter Body & Tip 0.079”/ 2.00 mm 0.079”/ 2.00 mmInner Diameter Body 0.057”/ 1.44 mm 0.057”/ 1.44 mmInner Diameter Tip 0.057”/ 1.44 mm 0.042”/ 1.06 mm

Page 19: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

17

JL 3.5 100 14102101 15102101 16102101 5JL 4 100 14102201 15102201 16102201 5JL 5 100 14102401 15102401 16102401 5

PIG 110 14114001 15114001 16114001 5PIG 130 14134001 15134001 16134001 5PIG 145 110 14114101 15114101 16114101 5PIG 145 130 14134101 15134101 16134101 5PIG 155 110 14114201 15114201 16114201 5PIG 155 130 14134201 15134201 16134201 5

Angiographic Catheter

Diagnostic Catheter for Angiography

Code-Number

Salesunit-pcs.

Shape description

Shape description

Shape description

Shape description

Shape description

Shape description

Shape description

length (cm) 4 French 5 French

JR 3.5 100 14102701 15102701 16102701 5JR 4 100 14102801 15102801 16102801 5JR 5 100 14103001 15103001 16103001 5

length (cm) 4 French 5 French 6 French

AL I 100 14100201 15100201 16100201 5AL II 100 14100301 15100301 16100301 5AL III 100 14100401 15100401 16100401 5

length (cm) 4 French 5 French 6 French

AR I 100 14100601 15100601 16100601 5AR II 100 14100801 15100801 16100801 5AR MOD 100 14100901 15100901 16100901 5

length (cm) 4 French 5 French 6 French

MPA I 100 14103601 15103601 16103601 5MPA - 2 sideholes 100 14103701 15103701 16103701 5

length (cm) 4 French 5 French 6 French

IM 100 14101701 15101701 16101701 5length (cm) 4 French 5 French 6 French

length (cm) 4 French 5 French 6 French

6 French

Pigtail - catheter for ventriculography - 8 sideholes

Judkins - catheter for the left coronary artery

Judkins - catheter for the right coronary artery

Amplatz - catheter for the left coronary artery

Amplatz - catheter for the right coronary artery

Multi Purpose catheter

Mammaria Interna catheter

Page 20: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

SONES I 100 14105901 15105901 16105901 5SONES II 100 14106101 15106101 16106101 5

3DS Williams right 100 14100001 15100001 16100001 5

LCB 100 14103401 15103401 16103401 5RCB 100 14105501 15105501 16105501 5

RADIAL 100 14105001 15105001 16105001 5

JL4/JR4/PIG 100/100/110 14316201 15316201 16316201 5

JL4/JR4/PIG145 100/100/110 14316301 15316301 16316301 5

18

Angiographic Catheter

Diagnostic Catheter for Angiography

Shape description length (cm) 4 French 5 French 6 French

Sones catheter - 2 sideholes

Shape description length (cm) 4 French 5 French 6 French

Bypass catheter

Shape description length (cm) 4 French 5 French 6 French

Catheter Kits

Code-Number

Salesunit-pcs.

Page 21: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

19

For more than 20 years B. Braun has been committed to provide customers worldwide with their customized Angiodyn Procedure Kit solutions.

Angiodyn are sterile kits that contain an organized array of disposable components for your specific procedure in interventional cardiology, radiology or hemodynamic measurements.

Angiodyn kits save procedural time since they facilitate patient preparation and post interven tional cleanup as compared to interventions that use individually packaged components. Therefore, the use of your cath lab is further optimized by allowing more interventions per day.

Angiodyn kits are cost effective by simplifying your purchasing and accoun-ting procedures and by consolidating components in one affordable kit.

Benefit from our impressive and wide range of high quality precision components.

Angiodyn stands for:

� Custom made kit solutions

� Precision components

� Quick and easy setup & cleanup

� Simple inventory control

� Convenient storage and delivery

� Increased output (= increased profitability)

� Consistent quality

� Standardized workflow (especially in emergency cases)

� Reduced training time for new staff

� Reduced waste volume

� More time with the patient

Customized Service

Customized Procedure Kits

Please contact one of our product specialists for further details.

Page 22: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Manifold assembly 3-way, ON 5010220 25

Manifold assembly 3-way, ON– high pressure manifold, 3-way, ON, connected with contrast media

tubing, Intrafix air and Combidyn tubing– angiography syringe 10 ml– arterial puncture needle (Seldinger) 18 G– Cutfix scalpel

Angiography kit 3-way, OFF 5010550 4

Angiography kit 3-way, OFF– high pressure manifold, 3-way, ON, connected with contrast media

tubing, Intrafix air and Combidyn tubing– angiography syringe 10 ml– arterial puncture needle (Seldinger) 18 G– Cutfix scalpel– angiography drape with 2 tranparent windows– standard guide wire, 150 cm, J3-tip, 0.035”– gauze, 10 x 10 cm, 12-ply, 20 pieces– Sterican needle, G 21 green, 2 pieces– Sterican needle, G 22 black– Omnifix syringe LL, 5 ml– Omnifix syringe LL, 10 ml– tray, 27 x 22 x 4 cm– cover drape 100 x 150 cm

Manifold assembly 2-way, OFF 5010440 25

Manifold assembly 3-way, OFF 5010660 25

20

Angiodyn

Standard Kits

Standard kitsMade for your success– save time during preparation– support your team during emergency situations– reduce your internal logistic costs– reduce packaging material and disposal costs

Manifold assembly 3-way, OFF– high pressure manifold, 3-way, OFF, connected with contrast media

tubing, Intrafix air and Combidyn tubing– angiography syringe 10 ml– arterial puncture needle (Seldinger) 18 G– Cutfix scalpel

Manifold assembly 2-way, OFF– high pressure manifold, 2-way, OFF, connected with contrast media

tubing and Combidyn tubing– angiography syringe 10 ml– arterial puncture needle (Seldinger) 18 G– Cutfix scalpel

Code-Number

Salesunit-pcs.

Page 23: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

21

J3 SFC-FS 150-035 150 0.035/0.89 5050227 10

J3 MC-FS 200-035 200 0.035/0.89 5050308 10J3 MC-FS 150-035 150 0.035/0.89 5050235 10

SFC 150-018 150 0.018/0.46 5050456 10SFC 150-035 150 0.035/0.89 5050243 10

Code-Number

Salesunit-pcs.

Angiodyn

Guide wire, PTFE-coated

J3 FC-FS 150-035 150 0.035/0.89 5050200 10J3 FC-FS 150-038 150 0.038/0.97 5050219 10J3 FC-FS 260-035 260 0.035/0.89 5050359 5

Øinch/mmlength (cm)product description

J-tip, fixed core (FC), fingerstraightenable (FS)

Angiodyn guide wiresFor insertion, stabilization and positioning of angiographic catheters

– PTFE-coated stainless nickel-chromium steel– flexible and smooth rounded wire tip– sensitive steering and guiding qualities– various tip configurations– straightener (only for J-tip)– standard: with dispenser and Luer lock-fitting for flushing the wire

Øinch/mmlength (cm)product description

Straight tip (S), fixed core (FC)

Øinch/mmlength (cm)product description

J-tip, movable core (M), fingerstraightenable (FS)

Øinch/mmlength (cm)product description

J-tip and straight tip (S) (flexible on both ends) fixed core (FC), fingerstraightenable (FS)

Further specifications available upon request.

Page 24: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

22

Code-Number

Salesunit-pcs.

Angiodyn

Mid and high pressure full-body manifolds

Angiodyn mid and high pressure full-body manifold– very smooth-turning handles (ergonomic design)– transparent housing for visual control– stopcocks tested up to 70 bar (1000 psi) pressure stability for

machine injection (yellow)– stopcocks tested up to 35 bar (500 psi) pressure stability for

manual injection (grey)– without rotating adaptor but with female luer lock-fitting– with rotating adaptor and male luer lock-fitting for

catheter connection

35 Rotating adapter male right 3 FRR 35 5012074 5070 Rotating adapter male right 3 FRR 70 5012066 50

descriptionconnectionsbar

Manifolds 3-port OFF version, yellow handles

35 Rotating adapter male right 2 FRR 35 5012112 5070 all female 2 FF 70 5012015 5070 Rotating adapter male right 2 FRR 70 5012104 50

descriptionconnectionsbar

Manifolds 2-port OFF version, yellow handles

35 Rotating adapter male right 3 ORR 35 5012813 5070 Rotating adapter male right 3 ORR 70 5012848 50

descriptionconnections

Manifolds 3-port ON version, grey handles

35 Rotating adapter male right 2 OR 35 5012759 5070 Rotating adapter male right 2 ORR 70 5012783 50

descriptionconnectionsbar

bar

Manifolds 2-port ON version, grey handles

Page 25: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

23

Angiodyn

Mid pressure half-body manifolds

35 Rotating adapter male right 3 FRR 35 5012094 50

descriptionconnectionsbar

Half-body manifolds 3-portOFF version

35 Rotating adapter male right 2 FRR 35 5012199 50

descriptionconnectionsbar

Half-body manifolds 2-portOFF version

35 Rotating adapter male right 3 ORR 35 5012893 50

descriptionconnectionsbar

Half-body manifolds 3-portON version

Angiodyn mid pressure half-body manifold– very smooth-turning of handles (ergonomic design)– transparent housing for visual control– pressure stability for mid pressure– without rotating adapter but with female luer-lock fitting– with rotating adapter and male luer-lock fitting for

catheter connection

Further specifications available upon request.

Page 26: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

24

Angiodyn

High pressure tubing with / without rotating adaptor

50 2.15 4.75 5018196 2075 2.15 4.75 5018200 20

100 2.15 4.75 5018218 20120 2.15 4.75 5018233 20150 2.15 4.75 5014875 20

outer ø (mm)inner ø (mm)length cm

male / female without rotating adaptor

50 2.15 4.75 5011957 2075 2.15 4.75 5011965 20

100 2.15 4.75 5011973 20120 2.15 4.75 5011938 20150 2.15 4.75 5018580 25

outer ø (mm)inner ø (mm)length cm

Angiodyn high pressure tubing up to 70 bar (1000 psi)— PVC, flexible

male / female with rotating adaptor

50 1.7 3.6 5011507 2575 1.7 3.6 5011515 25

100 1.7 3.6 5011523 25120 1.7 3.6 5011531 25200 1.7 3.6 5016002 25

outer ø (mm)inner ø (mm)length cm

Angiodyn high pressure tubing— transparent for visual control— tubing lengths for all needs— luer lock-fitting male / female

Angiodyn high pressure tubing up to 84 bar (1200 psi)— braided PUR, very flexible

male / female with rotating adaptor

Page 27: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

25

Angiodyn

Spectraline syringes / Contrast saver systems

syringe volumetypeplunger colour

Spectraline disposable syringes for connection with manifolds and catheters— for hand injection of contrast media, heparin, saline solution and

other liquids— clear polycarbonate barrel provides easy visualization of fluid levels

and allows accurate debubbling— larger 0.100 inch I.D. syringe tip delivers injections with less force— wider barrel flanges with finger grips for a better handling— ergonomic palm plunger fits easily into all size hands for optimum

comfort during usage— 10 ml and 20 ml syringes available in five colours— each syringe individually packaged with a label set

Code-Number

Salesunit-pcs.

white SP 10 W 10 ml 622460 25blue SP 10 B 10 ml 622461 25green SP 10 G 10 ml 622462 25yellow SP 10 Y 10 ml 622463 25red SP 10 R 10 ml 622464 25

white SP 20 W 20 ml 622465 25blue SP 20 B 20 ml 622466 25green SP 20 G 20 ml 622467 25yellow SP 20 Y 20 ml 622468 25red SP 20 R 20 ml 622469 25

Contrast saver tubing 5010552 50Contrast saver burette (without illustration) 5012000 50

Contrast saver tubing— connection between contrast saver spike and manifold— with large bore check valve to close the contrast media container

(to prevent a contamination with micro organisms)— length 140 cm

Contrast saver spike 5010557 50

Contrast saver system — System for saving of contrast media

Contrast saver spike — ventilated spike for contrast media container with Safesite® valve— applicable for several angiographic examinations — with integrated cover cap— length 15 cm

Page 28: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

26

Code-Number

Salesunit-pcs.

Angiodyn

Angiographic syringes / Injector syringes

10 ml angiographic syringe with rotating adapter 5011990 50

AngiodynAngiographic syringes for contrast media injection

— rubber gasket for smooth plunger action with double seal— crystal clear barrel

10 ml angiographic syringe with rotating adapter— ring plunger and medium sized grip plate— security stop at 1.0 ml— lateral finger rings

10 ml angiographic syringe with male Luer lock-fitting 5010142 50

Additional tubing 5017000 100

10 ml angiographic syringe with male Luer lock-fitting — medium sized grip plate— security stop at 1.0 ml

Angiodyn injector syringes– developed for high pressure injectors up to 84 bar / 1200 psi– transparent, high quality polypropylene for easy identification

of air bubbles– plunger with double seal prevents air aspiration and leakage– protective cap to avoid contamination when using aseptic technique– connection to all Luer standards possible

Additional tubing (without illustration)– to facilitate contrast media filling of injector syringes

0137NE 150 ml Angiomat 6000 TM 5010200 500137NF 150 ml Medrad (Mark V,...) 5010207 500137 NE

0137 NF

Page 29: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

27

Code-Number

Salesunit-pcs.

Angiodyn

Image intensifier covers and bags

60 65 5017745 25

width = W (cm)length = L (cm)

Angiodyn bag with string fixation

60 60 5016080 2590 100 5012629 25

width = W (cm)length = L (cm)

Angiodyn image intensifier bag with elastic fixation

35 70 5014022 2545 45 5016733 2575 80 5010438 2575 100 5010446 2580 120 5213568 25120 120 5010085 25140 140 5018912 25

width = W (cm)length = L (cm)

Angiodyn image intensifier cover with elastic fixation

Angiodyn image intensifier covers and bags – protect your equipment from contamination and dust– PE transparent cover– with elastic or string fixation

L

W

L

L

W

W

60 65 5012606 25

width = W (cm)length = L (cm)

Angiodyn table plastic cover (without illustration)colour: blue

Customized sets on request. Please ask your B. Braun clinical specialist.

Page 30: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

28

Code-Number

Salesunit-pcs.

Intradyn arterial

Arterial Introducer, Guide Wire, Puncture Needle

F 5 grey 5210704 20F 6 green 5210712 20F 7 orange 5210720 20

Intradyn arterial• with J3-guide wire

J3 SFV-40-035 5250529 25

Intradyn arterial guide wire• with J3-tip and straightener• 40 cm length, 0.035”• in dispenser

5208505 50

Intradyn arterial puncture needle• Smoothly tapered design for easy introduction of the guide wire

up to max. ø 0.035” (0.089 mm)

F 5 grey 5210763 20F 6 green 5210771 20F 7 orange 5210780 20

Intradyn arterial• without guide wire

Intradyn arterialIntroducer using the Seldinger technique according to Desilets-Hofmann

• Guide wire, 40 cm– made of stainless steel, ø 0.035" / 0.89 mm– flexible J3-tip with insertion tool or flexible straight tip

• Vessel dilator 160 mm, made of PE– flexible, minimal trauma to vessels– smoothly tapered transition to guide wire

• Sheath 130 mm, made of FEP– thin-walled– smoothly tapered transition to vessel dilatator– luer lock connection

• Hemostasis valve– to prevent retrograde blood flow– for arterial and venous application– smoothly tapered transition for easy introduction of catheter– sideport with three-way stopcock for easy administration

of I.V. solutions and injection of medications

gauge (G) ø (mm) length (mm) Colour

18 1.3 70 light pink

Page 31: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

29

Code-Number

Salesunit-pcs.

Intradyn Tear-Away

Tear-Away Introducer

F10 5212537 20

Intradyn dual Tear-Away Introducer

Intradyn dual Tear-Away IntroducerSplittable introducer set with two sheaths for the introduction of two probes for VDD- and DDD-pacemaker

Same content as Intradyn Tear-Away, however with two introducer sheaths and two dilatators

F6 5210313 20F7 5210593 20F8 5210321 20F9 5210330 20F10 5210348 20F11 5210585 20

Intradyn Tear-Away Introducer

Intradyn Tear-AwayTear-Away introducer sheath using the Seldinger technique according toDesilets-Hofmann

– the pre-scored tearing line ensures a clean and easy sheath removal after catheter placement

– the spin-lock connector holds dilatator and sheath together, preventingdilatator from backing out of sheath during vascular access

Intradyn Tear-Away• Intradyn puncture needle according to Seldinger1.3 x 70 mm (18 G)– made of stainless steel– smoothly tapered hub transition for easy introduction of guide wire

• Guide wire 40 cm– made of stainless steel, ø 0.035" / 0.89 mm – flexible J3-tip and flexible straight tip

• Vessel dilatator, 190 mm made of PE– flexible, minimal trauma to vessels– smoothly tapered transition to guide wire

• Introducer sheath, 160 mm made of FEP- thin-walled– smoothly tapered transition to vessel dilatator

• Syringe Luer lock-fitting 10 ml

Page 32: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

30

Code-Number

Salesunit-pcs.

Eledyn

Bipolar temporary balloon probe for anaesthesiaand intensive care

Eledyn stimulation probe with balloon F5 5101506 5

Add-ON set for Eledyn 2/F5 5150021 10

Eledyn Bipolar temporary balloon probe for transvenous heart stimulation

– excellent push and flexibility– catheter material: antithrombogenic Polyurethane (PUR), free of toxic

plasticizers– the use of stainless steel for electrode rings and wires prevents forma-

tion of galvanic elements– stainless steel, gold-plated 2 mm pins

• stimulation probe 110 cm– catheter marking every 100 mm from tip of the probe as an indicator

of depth of introduction and position of the probe– bipolar

• electrodes – electrode length 5 mm – electrode distance 10 mm– torque stability due to material and design– radio-opaque

• with floatation balloon• Omnifix® Lock– disposable syringe– with plunger stop for exact volume of air / CO2 for balloon inflation– for connection to balloon lumen with stopcock

Add-ON set for Eledyn 2/F5 – 1 Peel away canula Splittocan – 1 Connectable HemoStop venous– 1 Contamination guard– 4 Gauze pads 10x10cm, 8 plies– 1 Cutfix scalpel Fig. E11– 1 Seldinger puncture needle 1.3 x 70 mm, light pink– 1 Guide wire J3 SFU70-035 in dispenser and with a straightener– 1 Intradyn venous hemostasis introducer F5 with a blue stop cock,

two closing cones and one protection cover

Add-ON set for Eledyn 2/F6 and Eledyn F5 EB10 5150020 10

Add-ON set for Eledyn 2/F6 and Eledyn F5 EB10– 1 Contamination guard– 4 Gauze pads 10x10cm, 8 plies– 1 Cutfix scalpel Fig. E11– 1 Seldinger puncture needle 1.3 x 70 mm, light pink– 1 Guide wire J3 SFU70-035 in dispenser and with a straightener– 1 Intradyn venous hemostasis introducer F6 with a blue stop cock,

two closing cones and one protection cover.

PVC free

Page 33: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

31

Code-Number

Salesunit-pcs.

Eledyn 2/FX

Bipolar temporary stimulation probe for anaesthesia, intensive care and electrophysiology

Eledyn 2/F5 - straight 5151538 5Eledyn 2/F5 - C 5151554 5

Eledyn 2/F5

Eledyn 2/F6 - straight 5151562 5Eledyn 2/F6 - C 5151589 5

Eledyn 2/F6

Eledyn 2/F4 - straight 5151503 5Eledyn 2/F4 - C 5151520 5

Eledyn 2/F4

Eledyn 2/FX Bipolar temporary stimulation probes for transvenous heart stimulationand electrophysiology

– excellent push and flexibility due to special construction of the probes– individual ductility due to excellent memory effect (only straight tip)– the use of stainless steel for electrode rings and wires prevents

formation of galvanic elements– excellent torque stability– same handling in all french sizes and all types – stainless steel, gold-plated 2 mm pins

Technical data– electrode distance: 7 mm– material: stainless steel– effective length: 115 cm– catheter material: Polyamide, radio-opaque– resistance: < 50 Ω– plug: 2 mm gold plated

Eletrode surface: ring 11 mm2, tip 14 mm2

Eletrode surface: ring 14 mm2, tip 17 mm2

Eletrode surface: ring 19 mm2, tip 25 mm2

All Eledyn F4 an F5 probes include a peel-away cannula and a connectable Hemostop venous.

Intradyn Tear-Away F6 5210313 20

Recommended introducer for F6 probes:

PVC free

PVC free

Page 34: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

32

VascuFlexSE

Peripheral Stent System

VascuFlex SESelf-expandable Peripheral Stent System6F over-the-wire stent system with 8 radiopaque markers for peripheral interventions.

• Stent- excellent flow reconstruction and wall appositioning through

consistent radial force- optimal vessel conformability due to micromesh geometry- crush-recoverability thanks to one-piece laser cut Nitinol

stent material- high flexibility without change of lumen section through

helical cell design- excellent corrosion-resistance and biocompatibility due to

unique marker fixation technology- improved radiopacity thanks to high quality gold markers

• Delivery System- suppressed stent jumping due to unique

Precise Controlled Delivery (PCD) system - “Fast-in & fast-out” procedure with easy pull-back unlocking

mechanism - exact stent positioning with zero stent foreshortening and low

release forces - comfortable sheath rinsing with self-closing Safsite valve.- facilitated atraumatic catheter advancement with high performance

soft and flexible tip

• Technical data– over the wire system– guide wire compatibility: 0.035”– working length: 80 cm, 120 cm– guiding sheath fit: 6F

Page 35: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

33

Code-Number

Salesunit-pcs.

VascuFlex SE

Peripheral Stent System

80 cm 6 20 4431800 16 40 4431801 16 60 4431802 16 80 4431803 16 100 4431804 1

7 20 4431805 17 40 4431806 17 60 4431807 17 80 4431808 17 100 4431809 1

8 20 4431810 18 40 4431811 18 60 4431812 18 80 4431813 18 100 4431814 1

9 20 4431815 19 40 4431816 19 60 4431817 19 80 4431818 19 100 4431819 1

10 20 4431820 110 40 4431821 110 60 4431822 110 80 4431823 110 100 4431824 1

Stent Length (mm)

Stent Diameter(mm)

Working Length

• VascuFlex SE Order Information

Page 36: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

34 * upon request

Code-Number

Salesunit-pcs.

VascuFlex SE

Peripheral Stent System

120 cm 6 20 4431825 16 40 4431826 16 60 4431827 16 80 4431828 16 100 4431829 1

7 20 4431830* 17 40 4431831 17 60 4431832 17 80 4431833 17 100 4431834 1

8 20 4431835* 18 40 4431836 18 60 4431837 18 80 4431838* 18 100 4431839 1

9 20 4431840* 19 40 4431841 19 60 4431842 19 80 4431843* 19 100 4431844 1

10 20 4431845 110 40 4431846 110 60 4431847 110 80 4431848* 110 100 4431849 1

Stent Length (mm)

Stent Diameter(mm)

Working Length

• VascuFlex SE Order Information

Page 37: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

35

VascuFlex SEC

Carotid and Peripheral Stent System

VascuFlex SECSelf-expandable Carotid and Peripheral Stent System

5F Rapid Exchange stent system with 8 radiopaque markers for carotidand peripheral interventions

• Stent- excellent flow reconstruction and wall appositioning through

consistent radial force- optimal vessel conformability due to micromesh geometry- crush-recoverability thanks to one-piece laser cut Nitinol

stent material- high flexibility without change of lumen section through

helical cell design- excellent corrosion-resistance and biocompatibility due to

unique marker fixation technology- 8 radiopaque gold markers for good stent visibility

• Delivery system- easy lesion crossing and reduced puncture site trauma thanks

to 5F system - suppressed stent jumping due to unique Precise Controlled

delivery (PCD) system - exact stent positioning with zero stent foreshortening and low

release forces - “Fast-in & fast-out” procedure with easy pull-back unlocking

mechanism - comfortable sheath rinsing with self-closing Safsite® valve.- approved Rapid Exchange technology - facilitated atraumatic catheter advancement with high performance

soft and flexible tip

• Technical data- rapid-exchange system- guidewire compatibility: 0.014“- working length: 135 cm- guiding catheter: 7F (min. ID 2.06 mm / 0.081”)- guiding sheath fit: 5F (min. ID 2.06 mm / 0.081”)

Page 38: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

36

Code-Number

Salesunit-pcs.

VascuFlex SEC

Carotid and Peripheral Stent System

5 20 4442800 15 30 4442801 15 40 4442802 1

6 20 4442806 16 30 4442807 16 40 4442808 1

7 20 4442812 17 30 4442813 17 40 4442814 1

8 20 4442818 18 30 4442819 18 40 4442820 1

9 20 4442824 19 30 4442825 19 40 4442826 1

10 20 4442830 110 30 4442831 110 40 4442832 1

Stent Length (mm)

Stent Diameter(mm)

6 - 9 30 4442900 16 - 9 40 4442901 17 - 10 30 4442902 17 - 10 40 4442903 1

Stent Length (mm)

Stent Diameter tapered (mm)

• VascuFlex SEC Order Information

Page 39: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

37

Vena Cava Filters

For protection against pulmonary embolism

Vena Cava FiltersIndications:- contraindications to anticoagulants (severe coagulopathy,

thrombocy topenia, hemorrhage, recent brain surgery, recent cranialtrauma, ...)

- failure of the anticoagulants treatment (recurrent pulmonary em bolism under treatment development of clot in spite of anti-coagula tion)

- severe complication of the anticoagulants treatment (intestinal hemorrhage, gastroduodenal ulcer, ...)

Advantages:- proven conical design- long term temporary filter: up to 12 weeks (Tempofilter II)- made from Phynox, a non-ferromagnetic alloy with excellent MRI

compatibilty and X-Ray visibility- various access sites (VenaTech LP and VenaTech Convertible)- small, flexible introducer (VenaTech LP)- compatible with large Vena Cava (VenaTech LP and VenaTech

Convertible)- may be altered structurally to deactivate filtration

(VenaTech Convertible)

Code-Number

Salesunit-pcs.

Permanent filters access site

VenaTech LGM 30 D/U femoral, jugular 5010519 1VenaTech LP jugular, femoral, subclavian 4435125 1VenaTech LP brachial Introducer System brachial 4439985 1VenaTech LP Platinum Introducer System femoral, jugular, subclavian 4439986 1

Temporary filter access site

Tempofilter II jugular 4430098 1

Convertible filter access site

VenaTech Convertible femoral, jugular 4435140 1

Page 40: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

38

Pressure units

bar mm Hg cm H2O atm psi kPa

1 bar = 1 736 1019 0.987 14.51 100

1 mm Hg = 0.0013 1 1.39 0.0013 0.02 0.133

1 cm H2O = 9.81*10-4 0.736 1 0.0013 0.019 0.0981

1 atm = 1.013 745 1033 1 14.69 101.3

1 psi = 0.0689 50.71 70.21 0.068 1 6.89

1 kPa = 0.01 7.501 10.19 0.0099 0.145 1

Conversion tables

Metal cannula

Gauge Nominal outer diameter in mm* acc. to ISO 6009 colour code for injection cannulas

30 0.3 yellow

28 0.36 blue-green

26 0.45 brown

24 0.55 pink

22 0.7 black

20 0.9 yellow

18 1.2 rose

16 1.6 white

14 2.1 white-green

12 2.7 white-blue

*) according to ISO/DIN 9626

Catheter diameter 1 F = 1/3 mmFrench (F) 1 2 3 4 5 6 7 8 9 10 11 12 14

mm 0.33 0.67 1.0 1.33 1.67 2.0 2.33 2.67 3.0 3.33 3.67 4.0 4.67

Wire diameter 1” = 25.4 mmInch (“) 0.008 0.010 0.014 0.018 0.024 0.028 0.032 0.035 0.038 0.045 0.047 0.063 0.071

Fmm 0.20 0.25 0.36 0.46 0.61 0.71 0.81 0.89 0.97 1.14 1.19 1.60 1.80

Catheter length 1 foot = 30.5 cmFeet 1 2 3 4 5 6

cm 30.5 61.0 91.4 1.22 1.52 1.83

Page 41: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

39

EUROPEAUSTRIAB. Braun Austria GmbHOtto Braun - Straße 52344 Maria EnzersdorfPhone +43/22 36 46 54 10Fax +43/22 36 4 84 79

BELGIUMB. Braun Medical N. V./S. AWoluwelaan 140 b1831 DiegemPhone +32 70 22 33 00Fax +32 70 22 33 00

CZECH REPUBLICB. Braun Medical s. r. o.V Parku 2335/20148 00 Praha 4Phone +420/2/71 091 911Fax +420/2/71 091 912

DENMARKB. Braun Medical A/SSolbjergvej 3, 5 sal2000 FrederiksbergPhone +45/33 31 31 41Fax +45/33 31 14 23

ESTONIAB. Braun Medical OÜKadaka tee 70 b12618 TallinnPhone +372/6 77 12 00Fax +372/6 77 12 09

FINLANDB. Braun Medical OyHuopalahdentie 2400350 HelsinkiPhone +358/20/17 72 700Fax +358/20/17 72 720

FRANCEB. Braun Medical S. A. S.204, Av. du Maréchal-Juin92107 Boulogne - CedexPhone +331/41 10 53 00Fax +331/41 10 53 99

HUNGARYB. Braun Medical Kft.Montevideo u. 2/c1037 BudapestPhone +36/1/3 46 97 00Fax +36/1/4 38 49 00

IRELANDB. Braun Medical Ltd.3 Naas Road Industrial ParkDublin 12Phone +353/1/4 55 31 11Fax +353/1/4 55 31 15

ITALYB. Braun Milano S. p. A.Via V. da Seregno, 1420161 MilanoPhone +39/02 66 21 81 Fax +39/02 66 21 82 90

LATVIAB. Braun Medical SIAUdelu Str. 161064 Riga, LVPhone +371/678 19 549Fax +371/678 19 547

LITHUANIAB. Braun Medical UABAteities 1008303 VilniusPhone +370/2/37 43 33Fax +370/2/37 43 44

THE NETHERLANDSB. Braun Medical B. V.Euterpehof 10/Postbus 6595342 CW Oss/5340 AR OssPhone +31/4 12 67 24 11Fax +31/4 12 67 24 90

NORWAYB. Braun Medical A/SKjaernasveien 13 B3142 VestskogenPhone +47/33 35 18 00Fax +47/33 35 18 90

POLANDAesculap Chifa Sp. zo. oTysiaclecia 1464300 Nowy TomyslPhone +48/61/44 20 100Fax +48/61/4 42 39 36

PORTUGALB. Braun Medical Lda.Est. Consiglieri Pedroso, 80Queluz de Baixo2730-053 BarcarenaPhone +351/21/4 36 82 00Fax +351/21/4 36 82 80

RUSSIAB. Braun Medical LLC59, Bolshoy Pr.Petrogradskaja SideSaint Petersburg 197101Phone +7 (812) 320-40-04Fax +7 (812) 320-50-71

SLOVAKIAB. Braun Medical s. r. o.Handlovska 1985101 BratislavaPhone +421/2/63 83 89 20Fax +421/2/63 82 76 97

SPAINB. Braun Medical S. A.Carretera de Terrassa, 12108191 Rubi (Barcelona)Phone +34/93/5 86 62 00Fax +34/ 93/5 88 10 96

SWEDENB. Braun Medical ABSvärdvägen 2118211 DanderydPhone +46/8/6 34 34 00Fax +46/8/6 34 34 34

SWITZERLANDB. Braun Medical AGSeesatz 6204 SempachPhone +41/58 258 50 00Fax +41/58 258 60 00

TURKEYB. Braun Medical Irengrün DisTicaret A. S.Üniversite Mahallesi Civan Sokak No. 15 Aviclar34850 IstanbulPhone +90/21 25 90 35 60Fax: +90/21 25 91 94 30

UNITED KINGDOMB. Braun Medical Ltd.Thorncliffe ParkSheffield S35 2PWPhone +44/1 14/2 25 90 00Fax +44/1 14/2 25 91 11

NORTH AMERICAUSAB. Braun Medical Inc.824 Twelfth AvenueBethlehem, PA 18018Phone ++610-691-5400Fax: ++610-691-2202

LATIN AMERICAARGENTINAB. Braun Medical S. A.J. E. Uriburu, 663-7° PisoAR-(C1027AAM) Buenos AiresPhone +541/1 49 54-20 30Fax +541/1 49 54-75 27

BRAZILLaboratórios B. Braun S. A.Av. Eugenio Borges, 109224751-000 Sao Goncalo RJPhone +5521/6 02 33 10Fax +5521/6 02 31 89

CHILEB. Braun Comercial S. A.Calle Nueva 5335 - ConchaliSantiago de ChilePhone +562/4 40 71 00Fax +562/6 23 01 00

COLUMBIAB. Braun Medical S. A.Calle 44, No. 8-08Bogota D.C.Phone +571/3 40 30 01Fax +571/3 40 30 03

ECUADORB. Braun Medical S. A.Manuel Ambrosi 117y, Av. Eloy AlfaroManuel Ambrosi 117y Los CipresesTe.: +593/2/24 81/1 50Fax +593/2/24 83/0 31

MEXICOB. Braun Aesculapde México S. A. de C.V.Av. Vasco de Quiroga 2121 1er PisoCol. Santa Fe, Del. Alvaro ObrégonC. P. 01210 México, D.F.Phone +52/55/50897800Fax +52/55/50894975

PERUB. Braun Medical Peru S. A.Av. Separadora Industrial No. 887Lima 3Phone +511/3 26 18 25Fax +511/3 26 79 90

AUSTRALIAB. Braun Australia Pty. Ltd.Norwest Business Park17 Lexington DriveBella Vista NSW 2153Phone +61/2/96 29 02 00Fax +61/2/96 29 02 99

AFRICASOUTH AFRICAB. Braun Medical Ltd.Building 12B (Wentworth)Fourways Golf Park1016 Roos Street - Fourways2125 GautengPhone +27/11/5485500Fax +27/11/5485599

ASIACHINAB. Braun Medical (Shanghai) International Trading Co.Ltd.14A, New Shanghai International Tower360 Pudong Nan Lu-Pudong New DistrictShanghai 200120Phone +86/21/50 54 33 48Fax +86/21/50 54 33 53

HONGKONGB. Braun Medical (H.K.) Ltd.13-14/F. Henan Building 90 Jaffe Road Wanchai Hongkong Phone +852/25/29 20 09Fax +852/28/65 60 95

INDIAB. Braun Medical India Pvt Ltd5th Floor, East Quadrant, The I.L & F.S. Financial Centre, Bandra – Kurla Complex,Bandra (E), Mumbai,400051 MaharashtraPhone +91/22 66 68 22 22Fax +91/22 66 68 21 21

JAPANB. Braun Aesculap Japan Co. Ltd.38-16, Hongo 2-chome,Bunkyo-KuTokyo 113-0033Phone +81/3/3814 2525Fax +81/3/5684 7080

MALAYSIAB. Braun Medical IndustriesSdn. Bhd.Bayan Lepas Free Industrial ZoneP.O. Box 88010810 Penang Phone +60/4/6 32 31 00Fax +60/4/6 43 37 50

PAKISTANB. Braun Pakistan Ltd.Plot E-3, Farzana Building, Room #113rd Floor, Block 7&8,Main Shaheed-e-eMillat Road75400 KarachiPhone +92/21/4 54 10 17Fax +92/2 14 54 10 02

PHILIPPINESB. Braun Medical Supplies Inc.2nd Floor, The JMT Corporate Center, ADBAvenue, 1605 Pasig City Phone +632/633-72 84 to 95Fax +632/633-72 98

SINGAPOREB. Braun Singapore Pte. Ltd.600 North Bridge Road, #15-02/05Parkview Square188778 SingaporePhone +65/6/2 13 09 33Fax +65/6/2 13 09 30

SOUTH KOREAB. Braun Korea Co., Ltd.13th Floor, POSCO Center Bldg. 892Daechi 4-DongKangnam-Ku135-777 SeoulPhone +82/2 34 59 78 00Fax +82/2 34 53 30 60

TAIWANB. Braun Taiwan Co. Ltd.11/F, No. 132, Nanking E. Road, Sec. 3104 TaipeiPhone +886/2/27 21 99 00Fax +886/2/27 31 66 28

VIETNAMB. Braun Vietnam Co., Ltd.170 La Thanh Street - Dong Da DistrictHanoiPhone +84/4/35 11 00 88Fax +84/4/38 51 00 72

For further information about dealer networks etc. please contact the VascularSystems head office in Berlin.

B. Braun Vascular Systems

Page 42: B. Braun Vascular Systems Cardiology and Radiologychifa.com.pl/produkty/kardiologia/_files/katalog/...A novel concept of targeted, polymer-free and homogenous drug delivery designed

Brochure Nr. 6050125

All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or reproduced in any form. In the case of misuse we retain the rights to recall our catalogues and pricelists and to take legal actions.

Aesculap AG

Am Aesculap-Platz78532 TuttlingenGermany

Phone +49 7461 95-0Fax +49 7461 95-2600

www.aesculap.de

0209/3.0/4

For product information please contact:

B. Braun Melsungen AGAesculap Division - Vascular Systems

Sieversufer 812359 BerlinGermany

Phone +49 30 689897-0Fax +49 30 689897-30

www.bbraun.com

Distributed by: