1 IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. AXI 016 • Setup Guide This guide provides basic instructions for an experienced technician to install the AXI 016 Audio Expansion Interface. The AXI 016 is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. The AXI 016 is simple to use with no DSP processing hardware controls. For additional information and specifications, see the AXI 016 product page at www.extron.com. NOTES: EXP-enabled devices are devices that contain an Extron EXP port for routing 16 bidirectional channels of digital audio. In this guide, “EXP-enabled devices” and “EXP devices” are used interchangeably. Disconnect Power and Mount the AXI 016 Disconnect power from the AXI 016 and power off all devices that will be connected to it. The AXI 016 is housed in a half-rack width, 6-inch deep, 1U-high metal enclosure that can be rack mounted, set on a rack shelf, or placed on a table with the provided rubber feet. Select a suitable mounting location, then choose an appropriate mounting option. Rear Panel Connections AXI 016 9 10 11 12 1 2 3 4 OUTPUTS EXP INPUT POWER 12V 0.7 A MAX 13 14 15 16 5 6 7 8 EXP THRU PRIMARY DEVICE SECONDARY DEVICE A B D C A Power Inlet C EXP Input Port and LED B Analog Audio Outputs D EXP Thru Port and LED Figure 1. AXI 016 Rear Panel Connections A 12 VDC Power Inlet — Connect the 12 VDC power supply to the rear panel captive screw power inlet. Then, plug the power cable into the IEC inlet on the external power supply (see figure 2 below and the Attention notices on the next page). Rear Panel Power Receptacle DC Power Cord Captive Screw Connector Ground all devices. External Power Supply 12 VDC, 1.5 A max. – Return +12 VDC input Ridged Smooth Figure 2. Connecting the External Power Supply
5

AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

Sep 20, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

1

IMPORTANT:

Go to www.extron.com for the

complete user guide, installation

instructions, and specifications.

AXI 016 • Setup Guide

This guide provides basic instructions for an experienced technician to install the AXI 016 Audio Expansion Interface. The AXI 016 is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. The AXI 016 is simple to use with no DSP processing hardware controls. For additional information and specifications, see the AXI 016 product page at www.extron.com.

NOTES:• EXP-enabled devices are devices that contain an Extron EXP port for routing 16 bidirectional channels of digital audio.

• In this guide, “EXP-enabled devices” and “EXP devices” are used interchangeably.

Disconnect Power and Mount the AXI 016

Disconnect power from the AXI 016 and power off all devices that will be connected to it. The AXI 016 is housed in a half-rack width, 6-inch deep, 1U-high metal enclosure that can be rack mounted, set on a rack shelf, or placed on a table with the provided rubber feet. Select a suitable mounting location, then choose an appropriate mounting option.

Rear Panel Connections

AXI 016

9 10 11 12

1 2 3 4

OU

TP

UT

S

EX

P IN

PU

TPOWER12V 0.7 A MAX 13 14 15 16

5 6 7 8

EX

P T

HR

U

PRIMARYDEVICE

SECONDARYDEVICE

INPUT THRU

EXP

AUDIO EXPANSION INTERFACE

AXI 016

CLIP

SIGNAL

1 2 3 4 5 6 7 8 9 10 11 12OUTPUTS

13 14 15 16

A B DC

A B C

A Power Inlet C EXP Input Port and LED

B Analog Audio Outputs D EXP Thru Port and LED

Figure 1. AXI 016 Rear Panel Connections

A 12 VDC Power Inlet — Connect the 12 VDC power supply to the rear panel captive screw power inlet. Then, plug the power cable into the IEC inlet on the external power supply (see figure 2 below and the Attention notices on the next page).

Rear PanelPower Receptacle

DC Power Cord Captive Screw Connector

Ground all devices.

External Power Supply

12 VDC, 1.5 A max.

– Return+12 VDC input

Ridged

Smooth

1A M

AX

100-

240V

50-6

0Hz

Figure 2. Connecting the External Power Supply

Page 2: AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

2

ATTENTION:• Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all regulatory

compliance certification and may cause damage to the supply and the end product.

• Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.

• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.

• Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération ou dans les cavités murales. La source d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel dans un endroit ordinaire, avec un degré 2 de pollution, fixé à un équipement de rack à l’intérieur d’un placard, d’une estrade, ou d’un bureau.

• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.

• Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.

B Analog Audio Outputs — Use 6-pole, 3.5 mm captive screw connectors to connect up to 16 balanced or unbalanced line-level devices. Balanced or unbalanced mono devices can also be connected using 3-pole, 3.5 mm captive screw connectors.

Tip

SleeveTip

Sleeve

Tip

SleeveRing

Tip

SleeveRing

6-pole Audio OUTPUT WiringBalanced Output Unbalanced Output

NO Ground Here

NO Ground Here

3-pole Audio OUTPUT WiringUnbalanced Output

Tip

SleeveNO Ground Here

Balanced Output

Tip

SleeveRing

Figure 3. Audio Output Wiring

ATTENTION : • For unbalanced audio outputs, connect the sleeves to the ground contact. DO NOT connect the sleeves to the

negative (-) contacts.

• Pour l’audio asymétrique, connectez les manchons au contact au sol. NE PAS connecter les manchons aux contacts négatifs (–).

C EXP Input Port and LED — This RJ-45 EXP port connects the AXI 016 to the EXP port of a primary EXP device. The Expansion output channels of the primary EXP device are sent to the AXI 016 line outputs (see Connecting a Primary Device to the EXP Input Port on the next page). The LED to the right of the EXP INPUT port blinks to indicate a primary EXP device is connected.

NOTE: A primary EXP device is a device that has been set as a Primary Unit in DSP Configurator (see the DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DMP 128 Plus units are set to primary by default.

D EXP Thru Port and LED — This RJ-45 EXP port connects the Expansion output channels of a secondary EXP device to the AXI 016. When a primary EXP device is connected to the EXP INPUT port, the Expansion output channels of the secondary EXP device connected to the EXP THRU port are sent through the AXI 016 to the Expansion input channels of the primary device connected to the EXP INPUT port (see Connecting a Primary EXP Device and Secondary EXP Device on page 4). If no primary EXP device is connected to the EXP INPUT port, the Expansion output channels of the secondary EXP device connected to the EXP THRU port are sent to the AXI 016 line outputs (see Connecting a Secondary EXP Device to the EXP Thru Port on page 5). The LED to the right of the EXP THRU port lights solid to indicate a secondary EXP device is connected.

NOTE: A secondary EXP device is a device that has been set as a Secondary Unit in DSP Configurator (see the DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DTP CrossPoint units are set to secondary by default.

Page 3: AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

3

Front Panel Features

AXI 016

9 10 11 12

1 2 3 4

OU

TP

UT

S

EX

P IN

PU

TPOWER12V 0.7 A MAX 13 14 15 16

5 6 7 8

EX

P T

HR

U

PRIMARYDEVICE

SECONDARYDEVICE

INPUT THRU

EXP

AUDIO EXPANSION INTERFACE

AXI 016

CLIP

SIGNAL

1 2 3 4 5 6 7 8 9 10 11 12OUTPUTS

13 14 15 16

A B DC

A B C

Figure 4. AXI 016 Front Panel Features

A Power Indicator LED — This green LED lights solid when the AXI 016 is powered and fully operational.

B EXP Indicator LEDs — The green Input LED blinks to indicate a primary EXP device is connected to the rear-panel EXP INPUT port. The green Thru LED lights solid to indicate a secondary EXP device is connected to the rear-panel EXP THRU port.

C Output Signal and Clip LEDs — Sixteen pairs of stacked green and red LEDs light steadily when signal is present and increase in intensity from -60 dBFS (lowest intensity, signal presence indication) to -3 dBFS (full brightness). The red clip LEDs light solid to indicate clipping when a signal exceeds -3 dBFS. The red clip LEDs stay lit for one second after clipping ceases.

Application and Signal Flow Diagrams

The following diagrams display the different signal flows when primary and secondary EXP-enabled devices are connected to the AXI 016.

NOTE: Daisy-chaining two or more AXI 016 units together is not supported.

Connecting a Primary Device to the EXP Input Port

The diagram below displays the AXI 016 signal flow when only a primary EXP device, such as the DMP 128 Plus, is connected to the EXP INPUT port of the AXI 016.

• All 16 Expansion output channels of the primary device are routed to the line outputs of the AXI 016 (see path A1 in figure 5).

• Expansion output channel 1 of the primary device is routed to the AXI 016 line output 1, and so on.

AXI 016

9 10 11 12

1 2 3 4

OU

TP

UT

S

EX

P IN

PU

TPOWER12V 0.7 A MAX 13 14 15 16

5 6 7 8

EX

P T

HR

U

PRIMARYDEVICE

SECONDARYDEVICE

DMP 128 Plus (Primary Device)

AXI 016

LAN

DMP 128 Plus C

RxTx G

RS-232

+S+V -S G

G

4

O1O2 GIN

5

O1O2 GIN

6

O1O2 GIN

7

O1O2 GIN

8

O1O2

5 6 7 811 12

1 2 3 49 10

4 5 6 7 8

OU

TP

UT

S

DM

P E

XP

AC

P

REM

OTE

G

8

O1O2

8

Rxx G

RS-232

A1

A1

NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.

Figure 5. Basic Signal Flow from Primary EXP Device to AXI 016

A Power Indicator LED

B EXP Indicator LEDs

C Output Signal and Clip LEDs

Page 4: AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

4

Connecting a Primary EXP Device and Secondary EXP Device

The diagram below displays the signal flow when a primary EXP-enabled device is connected to the EXP INPUT port and a secondary EXP-enabled device is connected to the EXP THRU port.

• All 16 Expansion output channels of the secondary device are routed through the AXI 016 and into the primary EXP device Expansion input channels (see path B in the figure below).

• All 16 Expansion output channels of the primary EXP device are routed to the 16 analog line outputs of the AXI 016 (see path A1 in the figure below). Expansion output channel 1 of the primary EXP device is routed to the AXI 016 line output 1, and so on.

• All 16 Expansion output channels of the primary EXP device are also routed to the Expansion input channels of the secondary EXP device (see path A2 in the figure below). Expansion output channel 1 of the secondary EXP device is routed to Expansion input channel 1 of the primary EXP device, and so on.

AXI 016

9 10 11 12

1 2 3 4

OU

TP

UT

S

EX

P IN

PU

TPOWER12V 0.7 A MAX 13 14 15 16

5 6 7 8

EX

P T

HR

U

PRIMARYDEVICE

SECONDARYDEVICE

DMP 128 Plus (Primary Device)

AXI 016

DTP CrossPoint 108 4K (Secondary Device)

LAN

DMP 128 Plus C

RxTx G

RS-232

+S+V -S G

G

4

O1O2 GIN

5

O1O2 GIN

6

O1O2 GIN

7

O1O2 GIN

8

O1O2

5 6 7 811 12

1 2 3 49 10

4 5 6 7 8

OU

TP

UT

S

DM

P E

XP

AC

P

REM

OTE

G

8

O1O2

8

Rxx G

RS-232

50-60 Hz

100-240V ~--A MAX

1 2 3 4 5A 6A

XTP

Tx Rx RTS CTSG Tx Rx G Tx Rx G

RS-232 IR

Tx Rx Tx RxG

XTP

DTP

EXP

LIN

K

LAN 2

LAN 1

LAN 3

DTPHDBT

1 2 3 4 5 76

P CROSSPOINT 108 4K

R

OVER TPSIG LINK

IN

AU

DIO

INP

UT

S

CO

NT

RO

L 1 2 3 4 G

DIGITAL I/OCOM 3COM 2COM 1

S

DM

P E

XPA

NS

ION

SG G

11 22 C 3 4 C

INP

UT

S

-S G+S+V

PWR OUT = 6W

OU

TP

UT

S

RS-232 IR

Tx Rx Tx RxG

1L R

3L R

5L

2L R 4L R 6LIR/SERIAL eBUSRELAYS

SIG LINK

OUT

SIG LINK

OUT

5B 6B

RS-232 IR

Tx Rx Tx Rx

XTP

DTPHG

RS-232 IR

Tx Rx Tx RxG

OVER TP

1

1

CO

OIN

PU

TS

OU

TP

UT

S

INK

R L

R L

SIG

OOU

A1

B

B

A2B

A1

A2

NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.

Figure 6. Advanced Signal Flow when Primary and Secondary EXP Devices are Connected

Page 5: AXI 016 Setup Guide - Extron · AXI 016. NOTE: Daisy-chaining two or more AXI 016 units together is not supported. Connecting a Primary Device to the EXP Input Port The diagram below

68-3069-50 Rev. A10 17

Extron Headquarters+800.633.9876 Inside USA/Canada Only

Extron USA - West Extron USA - East+1.714.491.1500 +1.919.850.1000

+1.714.491.1517 FAX +1.919.850.1001 FAX

Extron Europe+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron Asia+65.6383.4400

+65.6383.4664 FAX

Extron Japan+81.3.3511.7655

+81.3.3511.7656 FAX

Extron China+86.21.3760.1568

+86.21.3760.1566 FAX

Extron Middle East+971.4.299.1800

+971.4.299.1880 FAX

Extron Australia+61.8.8113.6800+61.8.8351.2511 FAX

Extron India1800.3070.3777

(Inside India Only)

+91.80.3055.3777

+91.80.3055.3737 FAX

© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com

Connecting a Secondary EXP Device to the EXP Thru Port

The diagram below displays the signal flow when only a secondary EXP device such as the DTP CrossPoint 108 4K is connected to the EXP THRU port.

• All 16 Expansion output channels of the secondary EXP device are routed to the 16 line outputs of the AXI 016. The Expansion output channels of a secondary EXP device are only routed to the AXI 016 line outputs when no primary device is connected to the EXP INPUT port (see Connecting a Primary EXP Device and Secondary EXP Device on the previous page).

• Expansion output channel 1 of the secondary EXP device is routed to the AXI 016 line output 1, and so on.

AXI 016

9 10 11 12

1 2 3 4

OU

TP

UT

S

EX

P IN

PU

TPOWER12V 0.7 A MAX 13 14 15 16

5 6 7 8

EX

P T

HR

U

PRIMARYDEVICE

SECONDARYDEVICE

DTP CrossPoint 108 4K (Secondary Device)

50-60 Hz

100-240V ~--A MAX

1 2 3 4 5A 6A

XTP

Tx Rx RTS CTSG Tx Rx G Tx Rx G

RS-232 IR

Tx Rx Tx RxG

XTP

DTP

EXP

LIN

K

LAN 2

LAN 1

LAN 3

DTPHDBT

1 2 3 4 5 76

P CROSSPOINT 108 4K

R

OVER TPSIG LINK

IN

AU

DIO

INP

UT

S

CO

NT

RO

L 1 2 3 4 G

DIGITAL I/OCOM 3COM 2COM 1

S

DM

P E

XPA

NS

ION

SG G

11 22 C 3 4 C

INP

UT

S

-S G+S+V

PWR OUT = 6W

OU

TP

UT

S

RS-232 IR

Tx Rx Tx RxG

1L R

3L R

5L

2L R 4L R 6LIR/SERIAL eBUSRELAYS

SIG LINK

OUT

SIG LINK

OUT

5B 6B

RS-232 IR

Tx Rx Tx Rx

XTP

DTPHG

RS-232 IR

Tx Rx Tx RxG

OVER TP

1

1

CO

OIN

PU

TS

OU

TP

UT

S

INK

R L

R L

SIG

OOU

B

B

AXI 016

NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.

Figure 7. Basic Signal Flow from Secondary EXP Device to AXI 016