www.upsolar.com Upsolar Europe S.A.S China: Upsolar Co, Ltd. Hong Kong: Upsolar Co, Ltd. 15, Rue du Louvre, Silver Centre 19F, Rm 907, JSH001, Wing Tuck Comm Centre, 75001 Paris, France 1388 North Shan Xi Rd. Shanghai, China 177-183 Wing Lok Street, Hong Kong Tel: +33 1 83 62 02 00 Tel: +86 21 6277 5477 Tel: +852 2973 8324 Fax: +33 1 83 62 02 01 Fax: +86 21 6277 5664 Fax: +852 2111 0693 Avon PV Energy System Project Name: AVON Solar PV Energy System Department: Systems Application Focus Area: Design, Engineering, Procurement and Installation Product/Process: 16 kW PV SYSTEM Prepared By: Geof Moser & Glenn Gu A complete shading analysis was performed using computer aided design of the building occupied by Avon (a more extensive site analysis can be performed once the building is completed). Analysis shows that approximately 16 kW of installed PV can be placed on the roof structure of the building. Extensive shading on the buildings roof has determined the design format and layout of the PV system. The 3D drawing provided in this document should give a better understanding of this situation. *Please understand that as there is space for more solar modules to be placed on the roof, extensive shading on the PV modules would render them inefficient and cause excessive financial losses. PV SYSTEM COMPONENTS # SPECS Weight PV Module 72 220 Watt Poly (UP-M220P) 1368 kg Inverter 3 6 kW (EHE-N6k) 189 kg DC Disconnect 3 Heavy Duty Non-Fusible ST 3 Blade (1000 V DC) 15 kg AC Disconnect 3 Heavy Duty Non-Fusible (ST 3 Blade) 15kg Racking System 24 Ballasted (Non-Penetrating) 7800 kg Other BOS * Wiring, Conduit, Hardware 50 kg 9437 kg Ballasted Solar PV Design
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.upsolar.com
Upsolar Europe S.A.S China: Upsolar Co, Ltd. Hong Kong: Upsolar Co, Ltd. 15, Rue du Louvre, Silver Centre 19F, Rm 907, JSH001, Wing Tuck Comm Centre, 75001 Paris, France 1388 North Shan Xi Rd. Shanghai, China 177-183 Wing Lok Street, Hong Kong Tel: +33 1 83 62 02 00 Tel: +86 21 6277 5477 Tel: +852 2973 8324 Fax: +33 1 83 62 02 01 Fax: +86 21 6277 5664 Fax: +852 2111 0693
Avon PV Energy System
Project Name: AVON Solar PV Energy System
Department: Systems Application
Focus Area: Design, Engineering, Procurement and Installation
Product/Process: 16 kW PV SYSTEM
Prepared By: Geof Moser & Glenn Gu
A complete shading analysis was performed using computer aided design of the building occupied by Avon (a more extensive site analysis can be performed once the building is completed). Analysis shows that approximately 16 kW of installed PV can be placed on the roof structure of the building.
Extensive shading on the buildings roof has determined the design format and layout of the PV system. The 3D drawing provided in this document should give a better understanding of this situation.
*Please understand that as there is space for more solar modules to be placed on the roof, extensive shading on the PV modules would render them inefficient and cause excessive financial losses.
PV SYSTEM COMPONENTS # SPECS Weight PV Module 72 220 Watt Poly (UP-M220P) 1368 kg Inverter 3 6 kW (EHE-N6k) 189 kg DC Disconnect 3 Heavy Duty Non-Fusible ST 3 Blade (1000 V DC) 15 kg AC Disconnect 3 Heavy Duty Non-Fusible (ST 3 Blade) 15kg Racking System 24 Ballasted (Non-Penetrating) 7800 kg Other BOS * Wiring, Conduit, Hardware 50 kg