AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO Maggio 2019 A.B.E International team
43

AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Mar 20, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

AUTOMAZIONE PER IL LABORATORIO

MICROBIOLOGICOMaggio 2019

A.B

.E In

tern

atio

na

l te

am

Page 2: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

CHI SIAMO ?

• 40 km from Rennes

• 80 km from Nantes

• 390 km from Paris

Page 3: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Una gamma di strumenti

……………..More to come !

Page 4: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

PREPARAZIONE AUTOMATIZATA DEITERRENI DI COLTURA

(ISO 11133-2014)

(ISO 7218-2007 )

Page 5: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

MEDIAWEL30

Page 6: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

CULTURE MEDIA PREPARATION

Cosa ci dice la norma (ISO 7218-2007) ?

• 5.7.1 Description

• A media preparator is principally designed for the sterilization of large volumes of media (>1L). It

consists of a heating vessel, water jacket and continuous stirring device. The equipment shall also be fitted

with a temperature gauge, pressure gauge, timer and safety valve.

• In addition, the unit should have a safety lock to prevent opening until a temperature of 80 °C is reached.

NOTE: autoclave description (not autopreparator) → used for the destruction of the microorganisms. Maintain the

chamber at +/- 3°C (we don’t talk about the temperatura inside the culture media).

Microbiology of food and animal feeding stuffsGeneral requirements and guidance for microbiological examinations

Page 7: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

2) Critical points of the culture media preparation

Sterility Must reach a high enough temperature to STERILIZE the Culture Media(Ex.: 121°C-15min, 110°C-20min)

Fertility MUST NOT reach a too high temperature in order not to destroy the

culture media (destruction of the sugars, peptones…)

Remember the ISO : Autoclave (+/- 3°C minimum !) + slow to cool (45mins)

vs. MEDIAWEL (+/- 0.5°C) + rapid cooling down (15-20min)

Homogeneity So that the complete set is at the same temperature (with stability)

→ Media preparator with a temperatura probe inside the culture media + continuousstirring

Reproducibility You can reproduce the program with the same parameters to always have the same

quality (possibility to create programs)

AUTOMATED PREPARATION OF CULTURE MEDIA

Page 8: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

- PREPARATION TIME WITH A MANUAL METHOD

AUTOMATED PREPARATION OF CULTURE MEDIA

Dehydrated media

Purified water

MEDIAWEL cycleapprox: 75-85 mins

Autoclave approx CYCLE: 105-120 mins

- PREPARATION TIME WITH AUTOMATIZATION

TIME SAVED

Page 9: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

AUTOMATED PREPARATION OF CULTURE MEDIA

Page 10: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

• MEDIAWEL + ETRACE (included)

MEDIAWEL 30 Etrace – Traceability technology

= +

Standard :

Page 11: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough
Page 12: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough
Page 13: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough
Page 14: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

AUTOMATED PREPARATION OF CULTURE MEDIA

Page 15: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

5) Benefits & opportunities

HIGH PRODUCTIVE

- REPEATABLE

- LOW CONTAMINATION

AUTOMATED PREPARATION OF CULTURE MEDIA

Page 16: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

5) Benefits & opportunities

- OPTIONS w/ DISTRIWEL

- BLOOD ADDITION

- The blood is added during the dispensing (needs a second pump)

→ The blood addition can also be done with MEDIAWEL

- INK JET PRINTING

- Optional, with the LINX 10 (ref: AWLINX10)

and (DISW2004: fitting kit)

→ Up to 18 printable characters / 2 lines

(set number / name of the culture media / expiration date / …)

AUTOMATED PREPARATION OF CULTURE MEDIA

Page 17: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DOSYWEL : Pompa peristaltica

Page 18: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DOSYWEL : Pompa peristaltica

Page 19: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Pompa peristaltica completa

Programmazione :

- d’un volumine fisso di terreno da dispensare

- d’un intervallo tra doce (o possibilita’ del pedallo di controllo)

- numero di campioni

- calibration reminder

Page 20: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

PREPARAZIONE DEI CAMPIONI ALIMENTARI

(ISO 6887-1:2017)

(ISO 7218-2007 )

Page 21: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

PR

EPA

RA

ZIO

NE

CA

MP

ION

I ALI

MEN

TAR

I

Page 22: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

PREPARAZIONE CAMPIONI ALIMENTARI

Cosa ci dice la norma (ISO 6887-1:2017) ?

Microbiology of the food chainPreparation of test samples, initial suspension and decimal dilutions for microbiologicalexaminationPart 1: General rules for the preparation of the initial suspension and decimal dilutions

• 9.1 : Test and suspension (initial dilution): Weigh or measure the test take, with a tolerance of ± 5%,

in a sterile container or plastic bag (6.13). A mass of M G or a volume of V ml (at least 10 g or 10

ml, unless otherwise indicated) representative of the laboratory sample, must be used (see article

8).

• [...]

• Add a quantity of diluent equal to 9 × M G or 9 × V ml to prepare a decimal initial dilution. This

quantity must be measured, preferably in mass, with a tolerance of ± 2%, but the measurement in

volume is also admitted under the condition that the tolerance does not exceed ± 2%. »

Tells us that you need:

- A device with precision to

dilute at 1/10 (weights and

dispenses).

Very difficult with a manual

method

…more precisely: ISO 6579-1:2017 for Salmonella y ISO 11290-1 for Listeria= absence of 25 g (preparation of the sample with enrichment planned (dilution of 1/10 with

Peptone water (Salmonella) and with half Fraser (Listeria)

Page 23: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL : Dilutore gravimetrico

Page 24: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL : Dilutore Gravimetrico

Page 25: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL

Un dilutore gravimetrico combina :

- una bilancia

- pompa(e) per dispensare

Livello a bolla

+ 4 adaptable feet

« FACCIA LA PROVA ! SOTTOLEVATE SUL LATO E GUARDATE IL PESO

MISURATO☺ »

Page 26: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL

BRACCIA DI DISTRIBUZIONE AUTOMATIZZATO

= EVITA LA CONTAMINAZIONE CRUCIATA

Page 27: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL

COME SIAMO ARRIVATI A QUESTO RISULTATO?

- Pompe separate = Meno vibrazioni

- Bilancia verticale (3 punti) = piu’ stabilita’

- Software ottimizzato.

Rapido E Preciso

Page 28: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

28

13 kg (concorrenza)

DILUWEL Compattoleggero

Page 29: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

+34%

+17%

+34%

+20%

Concorrente A

Concorrente B

Altezza del sopporto della sacca → 30 cm !

DILUWEL

Page 30: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

30

PLUG & PLAY… DILUWEL

… FINO A 4 POMPE

- Connettare le pompe necessarie

- Meno vibrazioni sulla bilancia

- Servizio piu facile(moduli separati)

Page 31: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

31

• Compatto = spazio di lavoro risparmiato

• Pompa flessibile = facile da collegare il tubing

• Stabilita’ = precisione

• Low profile bag holder = no need to raise your arms

DILUWEL FACILE DA USARE IN CAPPA FLUSSO LUMINARE

Page 32: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

32

DILUWEL

Comfort and ergonomybetter control of the process

Sicurezza : Codici di colore

Se il suo campione è dentro del rango voluto, lo schermio diventa verde

= come una autorisazione di dispensare / dilure

Page 33: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

SICUREZZA = EVITARE LA CONTAMINAZIONE CRUCIATA

33

UNICO ! DILUWEL

Page 34: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Facile da pulire

34

DILUWEL

Page 35: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

DILUWEL

Tracciabilita’ → eTRACE® !

- Lettore barcode

- Stampante Ticket

- Chiave USB (export) → PC

Page 36: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Tracciabilita’ → eTRACE® !

DILUWEL

The LABPAGE

- Real time traceability

- Store the data

- Exportable to Excel

- The traceable information• Serial number / starting weight / final weight / % of dilution mistake / thinner /

Pump speed / analysis number / user / dillution factor / date / time of the day

Date of the last calibration

Page 37: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

UsoPer bottiglie(Cosmetico)

Page 38: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

MIXWEL : LaboratoryBlender

Page 39: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

MIXWEL

Page 40: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

Specifications

MIXWEL

• SILENT & COMPACT

SILENT (less than 48db) -

Vibration free

MIXWEL Innovative Laboratory blender

• INCREDIBLE POWER & EFFICIENCY

PATENTED pendular blending system

Autoadjustment of the paddles to the matrix

Delivers a power from 28 kg up to 70 kg pressure per paddle

EXCELLENT RESULTS WITH ANY TYPE OF MATRIX

Biomérieux

Interscience • EASY TO CLEAN

Quick removal of the door - Removable paddles

Waste drawer integrated into the door

14 kg

Small footprint

Specifications

MIXWEL

• SILENT & COMPACT

SILENT (less than 48db) -

Vibration free

MIXWEL Innovative Laboratory blender

• INCREDIBLE POWER & EFFICIENCY

PATENTED pendular blending system

Autoadjustment of the paddles to the matrix

Delivers a power from 28 kg up to 70 kg pressure per paddle

EXCELLENT RESULTS WITH ANY TYPE OF MATRIX

Biomérieux

Interscience • EASY TO CLEAN

Quick removal of the door - Removable paddles

Waste drawer integrated into the door

14 kg

Small footprint

MIXWEL

INCREDIBLE POWER AND EFFICIENCY

From 28 kg to 70 kg homogeneisation pressure per

paddle

Competition : Biomérieux, Seward, Interscience = 28kg

of pressure/paddle !

TESTIMONIALS

Page 41: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

MIXWEL

QUIET & COMPACT

QUIET

(less than 48db)

Few vibrations

14 kg

Very compact !

A

B

Biomérieux : 19,6 kg

Interscience : 26 kg

Page 42: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

EASY TO CLEAN

REMOVABLE DOOR AND PADDLES

Included waste drawer into the door

100% STAINLESS STEEL!MIXWEL

BAGMIXER (world leader)

-Plastic are cracking !

-Plastic is going out... needs

to be replaced.

-Hard to clean and some

critical points : gas spring

holes / liquid sensors...

Page 43: AUTOMAZIONE PER IL LABORATORIO MICROBIOLOGICO - soluzioni per automatizzazione laboratorio.pdf2) Critical points of the culture media preparation Sterility Must reach a high enough

ALCUNA DOMANDA?