Automatic Timer Instructions To enable an entry device or other accessory during specific hours IMPORTANT: If none of the control board diagrams in this manual match your operator control board call GTO Technical Service at 800-543-1236 for additional help. Step 1: Connect the device to the gate operator according to the installation instructions for the device. Step 2: Remove the wire from the device that is connected to the GREEN or COMMON terminal on the gate operator control board and connect it to the number 5 terminal on the timer. Take a piece of the same gauge wire and connect one end to the number 3 terminal of the timer and the other end to the GREEN or COMMON terminal on the gate operator control board. See illustrations on next page. Step 3: Connect a wire from the terminal 1 on the timer to the POSITIVE ( + ) battery wire. Step 4: Connect a second wire from terminal 2 on the timer to the NEGATIVE ( - ) battery wire. Step 5: Set the timer to activate at the hour and minute you would like the device to become enabled. Step 6: Set the timer to deactivate at the hour and minute you would like the device to become disabled. The entry device will function only during the hours that the timer is activated. 2005, www.hooverfence.com