Top Banner
American Medical Systems, Inc. World Headquarters 10700 Bren Road West Minnetonka, MN 55343 USA Phone: 952 930 6000 Fax: 952 930 6157 www.AmericanMedicalSystems.com American Medical Systems Europe B.V. Straatweg 66H 3621 BR Breukelen THE NETHERLANDS Phone: 31 346 258 100 Fax: 31 346 258 130 American Medical Systems Australia Pty. Ltd. Suite 2, Level 2 460 Church Street North Parramatta 2150 NSW AUSTRALIA Phone: 61 2 8838 8800 Fax: 61 2 9890 9899 American Medical Systems Canada Inc. P.O. Box 461 Guelph, Ontario N1H6K9 CANADA Phone: 519 826 5333 Fax: 519 821 1356 uRo Laser Type Quasi-Continuous Wave Laser Wavelength 532 nm Laser Power 0.5 to 15 watts StarPulse Peak Power NA Weight 60 lbs / 27 kg Dimensions 16''H x 12'' W x 23''D (42cm x 31cm x 58cm) Cooling Air cooled Electrical Requirements Single Phase • 100 VAC/20 Amps • 120 VAC/15 Amps • 230 VAC/10 Amps Exposure Duration 0.1 to 1 sec in 0.1 increments, then .5 sec increments to Continuous Exposure Intervals Single or 0.1 to 1 sec in 0.1 increments Pulse Rates NA AURA XP™ LASER SYSTEM SPECIFICATIONS gYn eNt AURA XP™ (STARPULSE™) LASER SYSTEM SPECIFICATIONS Laser Type Quasi-Continuous with StarPulse Laser Wavelength 532 nm Laser Power 0.5 to 15 watts StarPulse Peak Power 160W Weight 60 lbs / 27 kg Dimensions 16''H x 12'' W x 23''D (42cm x 31cm x 58cm) Cooling Air cooled Electrical Requirements Single Phase • 100 VAC/20 Amps • 120 VAC/15 Amps • 230 VAC/10 Amps Exposure Duration 1 to 50 milliseconds in 1msec increments, then .1 to 1 sec in 0.1 increment, then .5 sec increments to Continuous Exposure Intervals Single or 0.1 to 1 sec in 0.1 increments Pulse Rates 1 to 10 pulses per second when duration set between 1 to 50 milliseconds Order Number: 23000157A (08/07) ©2006 American Medical Systems, Inc. All rights reserved. Printed in USA. The laser system should only be used in conditions where its use is appropriate and of proven efficacy. Clinical applications should be under the direct supervision of a qualified surgeon. The use of the laser is contraindicated for patients: whose general medical condition contraindicates surgical intervention; where appropriate anesthesia is contraindicated by patient history; where tissue (especially tumors) has calcified; for hemostasis of vessels over approximately two millimeters in diameter; where laser therapy is not considered the treatment of choice. 153743_Aura Brochure.indd 1 8/24/07 12:27:29 PM
2

AuRA XP™ Laser system specifications Aura Brochure 09.pdfthe aura Xp™ 15 Watt laser system delivers massive performance, portability, and steady-state reliability for a range of

Jun 01, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AuRA XP™ Laser system specifications Aura Brochure 09.pdfthe aura Xp™ 15 Watt laser system delivers massive performance, portability, and steady-state reliability for a range of

American Medical Systems, Inc.World Headquarters10700 Bren Road WestMinnetonka, MN 55343USAPhone: 952 930 6000Fax: 952 930 6157www.AmericanMedicalSystems.com

American Medical SystemsEurope B.V.Straatweg 66H3621 BR BreukelenTHE NETHERLANDSPhone: 31 346 258 100Fax: 31 346 258 130

American Medical SystemsAustralia Pty. Ltd.Suite 2, Level 2460 Church StreetNorth Parramatta 2150NSW AUSTRALIAPhone: 61 2 8838 8800Fax: 61 2 9890 9899

American Medical SystemsCanada Inc.P.O. Box 461Guelph, OntarioN1H6K9 CANADAPhone: 519 826 5333Fax: 519 821 1356

uRo

Laser Type

Quasi-Continuous Wave

Laser Wavelength

532 nm

Laser Power

0.5 to 15 watts

StarPulse Peak Power

NA

Weight

60 lbs / 27 kg

Dimensions

16''H x 12'' W x 23''D(42cm x 31cm x 58cm )

Cooling

Air cooled

Electrical Requirements

Single Phase• 100 VAC/20 Amps• 120 VAC/15 Amps• 230 VAC/10 Amps

Exposure Duration

0.1 to 1 sec in 0.1 increments, then .5 sec increments to Continuous

Exposure Intervals

Single or 0.1 to 1 sec in 0.1 increments

Pulse Rates

NA

AuRA XP™ Laser system specifications

gYn

eNt

AuRA XP™ (StARPulSe™) Laser system specificationsLaser Type

Quasi-Continuous with StarPulse

Laser Wavelength

532 nm

Laser Power

0.5 to 15 watts

StarPulse Peak Power

160W

Weight

60 lbs / 27 kg

Dimensions

16''H x 12'' W x 23''D(42cm x 31cm x 58cm )

Cooling

Air cooled

Electrical Requirements

Single Phase• 100 VAC/20 Amps• 120 VAC/15 Amps• 230 VAC/10 Amps

Exposure Duration

1 to 50 milliseconds in 1msec increments, then .1 to 1 sec in 0.1 increment, then .5 sec increments to Continuous

Exposure Intervals

Single or 0.1 to 1 sec in 0.1 increments

Pulse Rates

1 to 10 pulses per second when duration set between 1 to 50 milliseconds

Order Number: 23000157A (08/07)©2006 American Medical Systems, Inc. All rights reserved. Printed in USA.

the laser system should only be used in conditions where its use is appropriate and of proven efficacy. clinical applications should be under the direct supervision of a qualified surgeon. the use of the laser is contraindicated for patients: whose general medical condition contraindicates surgical intervention; where appropriate anesthesia is contraindicated by patient history; where tissue (especially tumors) has calcified; for hemostasis of vessels over approximately two millimeters in diameter; where laser therapy is not considered the treatment of choice.

153743_Aura Brochure.indd 1 8/24/07 12:27:29 PM

Page 2: AuRA XP™ Laser system specifications Aura Brochure 09.pdfthe aura Xp™ 15 Watt laser system delivers massive performance, portability, and steady-state reliability for a range of

Designed to match Performance with Portability

Versatility. Portability. Affordability.the aura Xp™ 15 Watt laser system delivers massive performance, portability, and steady-state reliability for a range of soft tissue applications in the hospital, office or ambulatory surgery center.

Built to be moved quickly, easily and conveniently, the aura Xp laser system offers a versatile platform that enables continuous wave and pulsed mode (starpulse) operation applicable for Urology, ent, Gynecology and General surgery applications, expanding performance and maximizing investment.

Designed for Function as well as for Form

Aura XP VersatilityMultiple Applications

• Urology• ent• aesthetics• Gynocology• General surgery

Precise Cutting and Coagulationstar pulse limits the depth of penetration for increased control, while providing excellent hemostasis, vaporization, and cutting power.

Standard Electrical Utilitiesplug and play operation enables easy movement from one room to another and expedites procedure time.

Compact Designthe compact aura Xp easily fits in the smallest of procedure rooms and can operate from a counter top or portable cart.

Broad Fiber Optic Linea wide range of fiber optics deliver efficient treatment on numerous Uro, ent,Gyn, Derm and General surgery applications.Bare endostat™ iQ™ fiber optic line includes sizes 0.2, 0.3, 0.4 and 0.6 mm.

Solid-State Reliabilityreliable, solid-state construction sets a new standard for high performance with easy care maintenance.

153743_Aura Brochure.indd 2 8/24/07 12:27:35 PM