Top Banner
Atherectomy and IVUS
21

Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Sep 11, 2019

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Atherectomy and IVUS

Page 2: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Image of Healthy Vessel

600-0100.167/LD

Media

Intima Adventitia

Results are not predictive of future outcomesImage Courtesy of Philips Volcano

Page 3: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Material between the green line (intima) and red line (adventitia) is fibrotic plaque

IVUS Image of a Diseased Vessel

Results are not predictive of future outcomesImage Courtesy of Philips Volcano

600-0100.167/LD

Page 4: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

IVUS Post Directional Atherectomy

Results are not predictive of future outcomesIVUS Image Courtesy of Dr. Dippel

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 5: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

IVUS Post Directional Atherectomy

Results are not predictive of future outcomes.IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

Adventitial Injury

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 6: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Post Directional Atherectomy

Corresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

Results are not predictive of future outcomes.IVUS Image Courtesy of Dr. Prakash Krishnan

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 7: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Post Directional AtherectomyCorresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

Adventitial Injury

Results are not predictive of future outcomes.IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 8: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Post Directional AtherectomyCorresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

Adventitial Injury

Results are not predictive of future outcomes.IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 9: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

IVUS Post Orbital Atherectomy

Adventitial Injury

Results are not predictive of future outcomes. IVUS Image Courtesy of Dr. Staniloae

600-0100.167/LDThis specific case shows a sub-optimal outcome. However, there any many instances of orbital atherectomy where

there was a successful result.

Page 10: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of adventitial injury.

IVUS Post Orbital Atherectomy

Results are not predictive of future outcomes.IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

Adventitial Cut

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all orbital atherectomy case results.

Page 11: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of creating a dissection.

Dissection with Orbital Atherectomy

Results are not predictive of future outcomes.IVUS Image Courtesy of Dr. Staniloae

Dissection

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all orbital atherectomy case results.

Page 12: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Corresponding IVUS image demonstrates lumen gain at the expense of creating a dissection.

Lumen Gain at Expense of a Dissection

Results are not predictive of future outcomes.IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

Dissection

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all orbital atherectomy case results.

Page 13: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Dissection Post Aspirational Atherectomy

Results are not predictive of future outcomes. IVUS images obtain from actual cases with consent from the clinician. Data on file at Philips Volcano.

Pre-Aspirational Atherectomy Post-Aspirational Atherectomy

Dissection

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all aspirational atherectomy case results.

Page 14: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS performed on the left SFA showed localized dissection in the proximal and mid segments of the vessel.

IVUS demonstrated a significant dissection throughout the length of the right SFA.

Dissection Post Directional AtherectomyIVUS with ChromaFlo was used to assess the result post-atherectomy and balloon dilatation.

Results are not predictive of future outcomes.IVUS images provided by Dr. Dippel

Left SFA Post-Atherectomy

Dissection

Right SFA Post-Atherectomy

Dissection

600-0100.167/LD

This specific case shows a sub-optimal outcome. However, presented case result may not be indicative of all directional atherectomy case results.

Page 15: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

PRE-Phoenix – Concentric, calcified fibrotic SFA lesion.

POST Phoenix – Large luminal gain without adventitial injury.

IVUS with Phoenix

Results are not predictive of future outcomes.IVUS Images Courtesy of Dr. Gonzalez

600-0100.167/LD

Page 16: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

PRE-Phoenix – Concentric, non-calcified fibrotic SFA lesion.

POST Phoenix – Large luminal gain without adventitial injury.

IVUS with Phoenix

Results are not predictive of future outcomesIVUS Images Courtesy of Dr. Davis

600-0100.167/LD

Page 17: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

PRE-Phoenix POST Phoenix 2.4 - Large luminal gain without adventitial injury.

IVUS with Phoenix

Results are not predictive of future outcomes.IVUS Images Courtesy of Dr. Bennett

600-0100.167/LD

Page 18: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

Phoenix is Your Atherectomy Solution

Vessel Injury• Front cutter clears tissue in a way that may help reduce potential trauma to the vessel

Distal Embolization• Continuous capture and passive clearance of debulked material into the catheter resulted in a 1% rate of

symptomatic distal emboli1 in the EASE trial

Ease of Use• Single insertion - no need to remove and clean out debulked material• Battery powered handle operated - no capital equipment or additional procedural accessories required

Deliverability• Low profile, front cutting design allows for direct lesion access without having to first pass a nosecone• OTW design aids in trackability and pushability of catheter

Versatility• Treat a range of tissue types from soft plaque to calcified arteries• Treat most peripheral vasculature with only 3 catheter diameters2

1. Endovascular Atherectomy Safety and Effectiveness Study (EASE), ClinicalTrials.gov Identifier NCT01541774 (accessed 23Oct2015). Results presented at the Vascular Interventional Advances (VIVA) Conference in October of 2013 (Las Vegas, NV) by Stephen Williams, MD 2. Phoenix Atherectomy device is indicated for vessels 2.5mm in diameter and above

600-0100.167/LD

Page 19: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Can Assist You

Image courtesy of Philips Volcano

AssessCompleteness of Treatment

Is the stent fully apposed?

Did I cover the area of interest?

Did I achieve the necessary luminal gain?

Did I cut into the adventitia?

600-0100.167/LD

Page 20: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

IVUS Can Assist You

Images Courtesy of Philips Volcano

Pre-Treatment Strategy

What is the size of the vessel to be treated?

What type of plaque morphology does the patient have?

Where does the lesion start and end?

600-0100.167/LD

Page 21: Atherectomy and IVUS - Philipsimages.philips.com/is/content/PhilipsConsumer/Campaigns/HC20170613... · IVUS Image Courtesy of Dr. Staniloae. Dissection. 600-0100.167/LD This specific

600-0100.167/LD