8 AB BOLT M6X20 304S.S. HHB W/WASHER & GASKET F BATTEN BAR
(CLAMP BAR)
7
6
5
4
EXTRUDED EPDM GASKETS STAINLESS STEEL (1,4301) SEALING SCREWS
ACCORDING TO ASTM D1418 WITH EPDM GASKET (WEATHER GUARD DOMED)
EXCELLENCE GENERAL CLIMATE AND OZONE RESISTANCE
3 AB BOLT M6X20 304S.S. HHB W/WASHER & GASKET DOME
SHEET/PANEL
2
1
STAINLESS STEEL (1,4301) SEALING SCREWS WITH EPDM GASKET
(WEATHER GUARD DOMED) BATTEN BAR (CLAMP BAR) SECONDARY SEAL F
PRIMARY SEAL
DOME SHEET/PANEL E FLAME PROOF CONNECTION INTERLOCKING PANELS
WITH METAL-TO-METAL CLAMPING ASSURES MAXIMUM PANEL STRENGHT.
EXTRUSION BOLT CHANNEL DOME BEAM E
DOME BEAM
D
REINFORCEMENT TO PREVENT LOCAL BUCKLING OF THE PROFILE
AB BOLT EXTRUSION BOLT CHANNEL WEATHER GUARD DOMED WASHER
D
150,00
BOX BEAM-TYPE ALUMINIUM STRUT EXTRUSION WITH HIGH TORSIONAL
STIFFNESS TO PREVENT TORSIONAL BUCKLING
EPDM GASKET BATTEN BAR (CLAMP BAR) SECONDARY SEAL
C DOME SHEET/PANEL CORROSION RESISTANT HIGH STRENGTH AlMgSi
ALUMINIUM ALLOY FOR MAIN STRUT AND CLAMP BAR
PRIMARY SEAL
C
EXTRUSION BOLT CHANNEL
B
DOME BEAM
DOME BEAM
B DOME BEAM
BATTEN RIBBED DOME BEAM (TYPICAL)THIS DRAWING IS THE PROPERTY OF
AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR
WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
ATC100.DWG.TYP.M.103
TYPICAL BEAM PROFILE CROSS-SECTION3 2
PURCHASE NO :
X
8
7
1
8
7 AB BOLT M6X20 304S.S. HHB W/WASHER & GASKET
6 STAINLESS STEEL (1,4301) SEALING SCREWS WITH EPDM GASKET
(WEATHER GUARD DOMED)
5
4
3
2 AB BOLT
1
F
F
BATTEN BAR (CLAMP BAR)
EXTRUDED EPDM GASKETS ACCORDING TO ASTM D1418 EXCELLENCE GENERAL
CLIMATE AND OZONE RESISTANCE EPDM GASKET FLAME PROOF CONNECTION
WEATHER GUARD DOMED WASHER
SECONDARY SEAL DOME SHEET/PANEL PRIMARY SEAL E
DOME SHEET/PANEL E INTERLOCKING PANELS WITH METAL-TO-METAL
CLAMPING ASSURES MAXIMUM PANEL STRENGHT. DOME SHEET/PANEL
EXTRUSION BOLT CHANNEL
AB BOLT REINFORCEMENT TO PREVENT LOCAL BUCKING OF THE PROFILE D
BEAM/STRUT AB BOLT EXTRUSION BOLT CHANNEL D
BOX BEAM-TYPE ALUMINIUM STRUT EXTRUSION WITH HIGH TORSIONAL
STIFFNESS TO PREVENT TORSIONAL BUCKLING C
BOX BEAM-TYPE ALUMINIUM STRUT EXTRUSION WITH HIGH TORSIONAL
STIFFNESS TO PREVENT TORSIONAL BUCKLING
EPDM GASKET
C WEATHER GUARD DOMED WASHER WEATHER GUARD DOMED WASHER
CORROSION RESISTANT HIGH STRENGTH AlMgSi ALUMINIUM ALLOY FOR
MAIN STRUT AND CLAMP BAR
CORROSION RESISTANT HIGH STRENGTH AlMgSi ALUMINIUM ALLOY FOR
MAIN STRUT AND CLAMP BAR
REINFORCEMENT TO PREVENT LOCAL BUCKING OF THE PROFILE
B
DOME BEAM DOME BEAM EPDM GASKET
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
TYPICAL BEAM PROFILE AND BATTEN CONNECTION SECTION DETAIL3 2
ATC100.DWG.TYP.M.104PURCHASE NO :
X
8
7
1
8 AB BOLT M6X20 304S.S. HHB W/WASHER & GASKET F BATTEN BAR
(CLAMP BAR)
7
6
5
4
3 AB BOLT
2
1
STAINLESS STEEL (1,4301) SEALING SCREWS WITH EPDM GASKET
(WEATHER GUARD DOMED) EXTRUDED EPDM GASKETS ACCORDING TO ASTM D1418
EXCELLENCE GENERAL CLIMATE AND OZONE RESISTANCE
WEATHER GUARD DOMED WASHER BATTEN BAR (CLAMP BAR)
F
DOME SHEET/PANEL DOME PANEL FLAME PROOF CONNECTION PRIMARY SEAL
SECONDARY SEAL EXTRUSION BOLT CHANNEL E INTERLOCKING PANELS WITH
METAL-TO-METAL CLAMPING ASSURES MAXIMUM PANEL STRENGHT. AB BOLT
E
WEATHER GUARD DOMED WASHER EPDM GASKET BATTEN RIB (TYPICAL)
D
BEAM / STRUT
REINFORCEMENT TO PREVENT LOCAL BUCKLING OF THE PROFILE
D
DOME SHEET/PANEL BOX BEAM-TYPE ALUMINIUM STRUT EXTRUSION WITH
HIGH TORSIONAL STIFFNESS TO PREVENT TORSIONAL BUCKLING C CORROSION
RESISTANT HIGH STRENGTH AlMgSi ALUMINIUM ALLOY FOR MAIN STRUT AND
CLAMP BAR C
DOME BEAM DOME BEAM B B
TYPICAL BEAM & BATTEN CONNECTION
DOME BEAM
BATTEN RIBBED DOME BEAMS SECTIONTHIS DRAWING IS THE PROPERTY OF
AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR
WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
ATC100.DWG.TYP.M.105
TYPICAL BEAM AND BATTEN SECTION AND ISOMETRIC3 2
PURCHASE NO :
X
8
7
1
8 AB BOLT M6X20 304S.S. HHB W/WASHER & GASKET
7
6
5
4
3
2
1
F
STAINLESS STEEL (1,4301) SEALING SCREWS WITH EPDM GASKET
(WEATHER GUARD DOMED)
BATTEN BAR (CLAMP BAR) DOME SHEET/PANEL
16 BOLT PATTERN 12 BOLT PATTERN 8 BOLT PATTERN 4 BOLT
PATTERN
F
FLAME PROOF CONNECTION E E
INTERLOCKING PANELS WITH METAL-TO-METAL CLAMPING ASSURES MAXIMUM
PANEL STRENGHT.
EXTRUSION BOLT CHANNEL
BATTEN SEAM DETAIL A
D TYPICAL INTERNAL/TENSION BEAM
TYPICAL BATTEN RIB
BATTEN RIB (TYPICAL)
D
DOME SHEET/PANEL BOX BEAM-TYPE ALUMINIUM STRUT EXTRUSION WITH
HIGH TORSIONAL STIFFNESS TO PREVENT TORSIONAL BUCKLING
REINFORCEMENT TO PREVENT LOCAL BUCKLING OF THE PROFILE
S1BATTEN SEAMS NOTES1 CORDS FOR MAXIMUM SEALING EFFICIENCY
SILICONE SEAL CORDS TO MAXIMIZE LIFE UNDER ALL SERVICE CONDITIONS.
2 SOLID CORDS TO AVOID ANY ABSORPTION OF WATHER OR CHEMICALS.
S2
S3
S4
S5C
TYPICAL BATTEN RIBBED DOME BEAM DETAILSBATTEN RIBBED BEAMS
GENERAL NOTES1 TENSION AND INTERNAL BEAM SIZES, WEIGHT, THICKNESS
AND AREA WILL VERY ACCORDING TO THE INDIVIDUAL STRESS REQUIREMENTS.
2 FLANGE BOLT HOLE PATTERNS ARE DETERMINED BY SIZE AND LOADING
CONDITIONS, REFERANCE STRESS SUMMARY SHEET FOR DETAILS. 3 TENSION
BEAM WEB HOLES ARE REQUIRED ONLY WHEN A TENSION TIE STRAP IS CALLED
FOR IN THE STRESS SUMMARY SHEET. THE NUMBER OF B TENSION TIE HOLES
AND PATTERN WILL WARRY WITH LOADING CONDITIONS.
C
CORROSION RESISTANT HIGH STRENGTH AlMgSi ALUMINIUM ALLOY FOR
MAIN STRUT AND CLAMP BAR
3 FULLY ENCLOSED SEAL CORDS, TO AVOID THE ENVIRON MENTAL HAZARDS
OF EXPOZED ELASTOMERS. (CONDINOUS FULL LENGHT OF BATTEN BAR) 4 LOW
PROFILE - INSTALLED BATTEN ONLY '' ABOVE SKIN PANEL.
B
5 METAL-TO-METAL GRIP-SERRATED CENTER RIBS OF BATTEN CLAMP SKIN
PANEL EDGES TIGHLY AGAINST SERRATED BEAM FLANGE. RIBS ARE DIRECTLY
BELOW FASTENER PROVIDING MAXIMUM PRESSURE. 6 ALL TEMPERATURE
INSTALLATION - SPRING ACTION OF THE BATTEN ''WINGS'' INSURES
UNIFORM PRESSURE AGAINST THE SEAL CORDS DURING COLD WEATHER
INSTALLATION WHEN THE CORDS ARE ''FIRM''. THE SAME SPRING ACTION
INSURES A TIGHT SEAL AS THE TEMPERATURE RISES AND THE SEAL CORDS
SOFTEN.
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
BATTEN BEAM & BATTEN RIBBED TYPICAL BEAM DETAILS2
ATC100.DWG.TYP.M.106PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2 DOME SHEET(PANEL (1,2mm)
1
F
SILICONE SEALANT AROUND EACH GUSSET COVER
CIRCULAR HUB COVER F HUB COVER CLIPS
HUB COVER CLIPS
SECTION B - BE AB BOLTS '' (M6) DIA x 25 mm LONGW/WASHER &
GASKET (304S.S. HHB)
E
D SILICONE SEALANT BETWEEN GUSSET PLATE AND PANEL AT ENDS OF
BATTEN BAR CIRCULAR FORMED TOP GUSSETS (NODE PLATE) 9,5mm DIA. AL.
LOCK BOLTS, STRUT FLANGE TO GUSSET EACH END 4 TOP AND 4 BOTTOM
D
BC
B
SILICONE SEALANT BETWEEN HUB COVER AND PANEL CORNER
C BATTEN BAR (ALUMINIUM) CIRCULAR FORMED BOTTOM GUSSETS (NODE
PLATE) GASKET BETWEEN HUB COVER TYPICAL GUSSET JOINT AND PANEL
(SPECIAL) DOME SHEET/PANEL (1,2mm) CLOCED END SEALING RIVETS -
(ALU) 4 DIA x 15 GRIP (TYP. 2 OF EACH PANEL 6 PLCS) ALL MATERIAL
EXCEPT AS OTHERWISE NOTED IS MILL FINISH ALUMINIUM AS FOLLOWS;
*STRUT/BEAM, GUSSETS AND PLATES: 6061-T6 *PANELS, FLASHING AND
GUSSETS COVERS: 3003-H16 *BATTENS: 6061-T6
B
FASTENERS; LOCKBOLTS - ALU.7075-T3 OR S.S.304 AS NOTED
(AL.LOCKBOLTS CLEAN ANOTIZED S.S.204) LOCKBOLTS COLLARS - ALUMINIUM
(6061 HEAT TREATED) SHOE SUPPORT PLATE BOLTS - S.S.304 BATTEN SCREW
- '' DIA. S.S.
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) SEALANT; 3M,
PECORA, DOW, HENKEL SILICONE SEALANT MEETING ATECO SPEC.
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HUB CONNECTION DETAILS SECTION3 2
ATC100.DWG.TYP.M.107PURCHASE NO :
X
8
7
1
8
7
6
5
4 CIRCULAR HUB COVER
3 SILICONE SEALANT AROUND EACH GUSSET COVER
2
1 CIRCULAR FORMED TOP GUSSETS (NODE PLATE) F
F
CIRCULAR HUB COVER
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB)
B
SECTION A - AE DOME BEAM DOME SHEET/PANEL ALUMINIUM DOME BEAM
150mm DEEP BEAM (TYPICAL) HUB COVER CLIPS BATTEN BAR (ALUMINIUM)
GASKET BETWEEN HUB COVER TYPICAL GUSSET JOINT AND PANEL (SPECIAL)
E
DETAIL - B
CIRCULAR HUB COVER
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB) D
BATTEN BAR (ALUMINIUM) DOME SHEET/PANEL
DETAIL - C
D
AC
A
C
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
C
DOME SHEET/PANEL
B CLOCED END SEALING RIVETS - (ALU) 4 DIA x 15 GRIP (TYP. 2 OF
EACH PANEL 6 PLCS)
B
CIRCULAR HUB COVER
D DETAIL - D
HUB COVER CLIPS
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HUB CONNECTION POSITION AND TYPICAL VIEW3 2
ATC100.DWG.TYP.M.108PURCHASE NO :
X
8
7
1
8
7
6
5
4
3 AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET
(304S.S. HHB)
2
1
F
GASKET BETWEEN HUB COVER TYPICAL GUSSET JOINT AND PANEL
(SPECIAL)
HUB COVER CLIPS
CIRCULAR HUB COVER F DOME SHEET(PANEL (1,2mm) DOME SHEET(PANEL
(1,2mm)
BATTEN BAR (ALUMINIUM) E E
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
D
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) ALUMINIUM DOME
BEAM 150mm DEEP BEAM (TYPICAL) CIRCULAR FORMED TOP GUSSETS (NODE
PLATE)
D
DETAIL - ACIRCULAR FORMED TOP GUSSETS (NODE PLATE) C
AC
CIRCULAR HUB COVER
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB) ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) B ALL MATERIAL
EXCEPT AS OTHERWISE NOTED IS MILL FINISH ALUMINIUM AS FOLLOWS;
*STRUT/BEAM, GUSSETS AND PLATES: 6061-T6 *PANELS, FLASHING AND
GUSSETS COVERS: 3003-H16 *BATTENS: 6061-T6 FASTENERS; LOCKBOLTS -
ALU.7075-T3 OR S.S.304 AS NOTED (AL.LOCKBOLTS CLEAN ANOTIZED
S.S.204) LOCKBOLTS COLLARS - ALUMINIUM (6061 HEAT TREATED) SHOE
SUPPORT PLATE BOLTS - S.S.304 BATTEN SCREW - '' DIA. S.S. CIRCULAR
FORMED BOTTOM GUSSETS (NODE PLATE)
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) CLOCED END SEALING
RIVETS - (ALU) 4 DIA x 15 GRIP (TYP. 2 OF EACH PANEL 6 PLCS) B
CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE)
SEALANT; 3M, PECORA, DOW, HENKEL SILICONE SEALANT MEETING ATECO
SPEC.
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HUB CONNECTION DETAIL ASSEMBLY EXPLODED3 2
ATC100.DWG.TYP.M.109PURCHASE NO :
X
8
7
1
8 SILICONE SEALANT AROUND EACH GUSSET COVER F
7 HUB COVER CLIPS
6 CIRCULAR HUB COVER
5
4
3
2
1
DOME SHEET(PANEL (1,2mm)
CIRCULAR HUB COVER
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
F
DALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
E
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) CIRCULAR FORMED
TOP GUSSETS (NODE PLATE) AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER
& GASKET (304S.S. HHB) CIRCULAR HUB COVER DOME SHEET(PANEL
(1,2mm)
E
D CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) AB BOLTS '' (M6)
DIA x 25 mm LONG W/WASHER & GASKET (304S.S. HHB) ALUMINIUM DOME
BEAM 150mm DEEP BEAM (TYPICAL) C BATTEN BAR (ALUMINIUM) GASKET
BETWEEN HUB COVER TYPICAL GUSSET JOINT AND PANEL (SPECIAL)
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) CIRCULAR FORMED TOP
GUSSETS (NODE PLATE) HUB COVER CLIPS
D
C
DETAIL - DBATTEN BAR (ALUMINIUM)
B
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HUB CONNECTION SECTION AND GASKET DETAIL AND COVER DETAIL3 2
ATC100.DWG.TYP.M.110PURCHASE NO :
X
8
7
1
8 DOME STRUCTURE F SLIDING SUPPORT
7
6
5
4
3
2
1
FIXED SUPPORT F
BATTEN BAR (ALUMINIUM) STEEL TENSION / COMPRESSION RING STEEL
TENSION /COMPRESSION RING E E
BIRD SCREEN D RAIN FORCING TANK SHELL D
C
C
TANK SHEEL B BIRD SCREEN DOME SHEET/PANEL B
BIRD SCREEN DETAILTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS
NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT
OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
FIXED SUPPORT - FREE VENTED2
ATC100.DWG.TYP.M.111PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
DOME STRUCTURE F DOME STRUCTURE STEEL TENSION / COMPRESSION RING
SUPPORT BAR HEX SOCKET BOLTS FIXED SUPPORT BOLT
DOME STRUCTURE F HEX SOCKET BOLT
SUPPORT BAR E STEEL TENSION / COMPRESSION RING DOME STRUCTURE
E
BOLTS D SAFETY PIN FIXED SUPPORT BOLTS D
FIXED SUPPORT
BOLT
C
FIXED SUPPORT SUPPORT BAR
C
SAFETY PIN NUTS STEEL TENSION / COMPRESSION RING
STEEL TENSION / COMPRESSION RING B NUTS B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
FIXED SUPPORT DETAIL2
ATC100.DWG.TYP.M.112PURCHASE NO :
X
8
7
1
8 ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
7
6
5 DOME STRUCTURE
4
3 DOME STRUCTURE FIXED SUPPORT
2
1 BATTEN BAR (ALUMINIUM) F
DOME SHEET/PANEL BOLT BATTEN BAR (ALUMINIUM) STEEL TENSION /
COMPRESSION RING
F
E CIRCULAR FORMED TOP GUSSETS (NODE PLATE) CIRCULAR FORMED
BOTTOM GUSSETS (NODE PLATE) FIXED SUPPORT D BOLT SAFETY PIN STEEL
TENSION / COMPRESSION RING
M8 HEX SOCKET BOLT BIRD SCREEN BATTEN BAR STEEL TENSION /
COMPRESSION RING ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) TANK
SHELL
E
D
DOME SHEET
C
CIRCULAR FORMED TOP GUSSETS (NODE PLATE) CIRCULAR FORMED BOTTOM
GUSSETS (NODE PLATE) FIXED SUPPORT STEEL TENSION / COMPRESSION
RING
DOME STRUCTURE C BATTEN BAR
B
TANK SHELL
B
BIRD SCREEN
DOME SHEET/PANEL
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
FIXED SUPPORT DETAIL ASSEMBLY3 2
ATC100.DWG.TYP.M.113PURCHASE NO :
X
8
7
1
8
7
6
5
4
3 DOME STRUCTURE
2
1
F DOME STRUCTURE
STEEL TENSION / COMPRESSION RING
AFIXED SUPPORT SUPPORT BAR
F
A
E
STEEL TENSION / COMPRESSION RING FIXED SUPPORT DOME SHEET BATTEN
BAR
E STEEL TENSION / COMPRESSION RING
AD SUPPORT BAR TANK SHELL
STEEL TENSION / COMPRESSION RING
D
DOME SHEET C SEAL TANK SHELL C
B
STEEL TENSION / COMPRESSION RING
B
DETAIL - ASECTION A - ATHIS DRAWING IS THE PROPERTY OF AKTEK. IT
IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN
CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
FIXED SUPPORT - PRESSURE TIGHT3 2
ATC100.DWG.TYP.M.114PURCHASE NO :
X
8
7
1
8 DOME STRUCTURE F SLIDING SUPPORT
7
6
5
4
3
2
1
SLIDING SUPPORT F GUIDANCE BATTEN BAR (ALUMINIUM)
LOW FRICTION PADS
STEEL TENSION /COMPRESSION RING E E
BIRD SCREEN D RAIN FORCING TANK SHELL D
C
C
TANK SHEEL B BIRD SCREEN DOME SHEET/PANEL B
BIRD SCREEN DETAILTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS
NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT
OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
SLIDIN SUPPORT - FREE VENTED2
ATC100.DWG.TYP.M.115PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
DOME STRUCTURE
M8 BOLT DOME STRUCTURE
F
SLIDING SUPPORT
GUIDANCE E BOLT
SLIDING SUPPORT E
SUPPORT BAR SUPPORT BAR SAFETY PINS CLAMP
BOLTS SPACER PLATE CLAMP D CLAMP SAFETY PINS D
LOW FRICTION PADS SLIDING SUPPORT SPACER PLATE C LOW FRICTION
PADS
C
SPACER PLATE LOW FRICTION PADS
SPACER PLATE B
NUTS B STEEL TENSION / COMPRESSION RING
STEEL TENSION / COMPRESSION RING
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
SLIDING SUPPORT DETAIL2
ATC100.DWG.TYP.M.116PURCHASE NO :
X
8
7
1
8
7
6
5
4
3 DOME STRUCTURE
2
1 BATTEN BAR (ALUMINIUM)
F
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
SLIDING SUPPORT DOME SHEET/PANEL BATTEN BAR (ALUMINIUM)
SLIDING SUPPORT LOW FRICTION PADS GUIDANCE STEEL TENSION
/COMPRESSION RING
F
E CIRCULAR FORMED TOP GUSSETS (NODE PLATE) CIRCULAR FORMED
BOTTOM GUSSETS (NODE PLATE) HEX SOCKET BOLT CLAMPING BAR M8 HEX
SOCKET BOLT LOW FRICTION PADS RAIN FORCING BIRD SCREEN
E
D
SPACER PLATE STEEL TENSION / COMPRESSION RING
D
CIRCULAR FORMED TOP GUSSETS (NODE PLATE) CIRCULAR FORMED BOTTOM
GUSSETS (NODE PLATE) C BOLT CLAMPING BAR SPACER PLATE TANK SHELL
STEEL TENSION / COMPRESSION RING B SUPPORT BAR SLIDING SUPPORT LOW
FRICTION PADSTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
TANK SHEEL
C
B BIRD SCREEN DOME SHEET/PANEL
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
SLIDING SUPPORT DETAIL ASSEMBLY3 2
ATC100.DWG.TYP.M.117PURCHASE NO :
X
8
7
1
8 DOME STRUCTURE F
7
6
5
4
3 DOME STRUCTURE
2
1 SLIDING SUPPORT F SUPPORT BAR LOW FRICTION PADS
CLAMP STEEL TENSION / COMPRESSION RING CLAMP POLYGONAL STEEL
RING SPACER PLATE BOLT
SLIDING SUPPORT STEEL TENSION / COMPRESSION RING DOME SHEET
STEEL TENSION / COMPRESSION RING SLIDING SUPPORT GUIDANCE SPACER
PLATE STEEL TENSION / COMPRESSION RING FLEXIBLE SEAL D POLYGONAL
STEEL RING TANK SHELL BOLT STEEL TENSION / COMPRESSION RING SEAL
BATTEN BAR CLAMP DOME SHEET D
E
SPACER PLATE
FLEXIBLE SEAL
E
A
DETAIL - A - ISOMETRIC
C TANK SHELL
C
B WELD POLYGONAL STEEL RING FLEXIBLE SEAL
B
DETAIL - A
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
SLIDING SUPPORT - PRESSURE TIGHT3 2
ATC100.DWG.TYP.M.118PURCHASE NO :
X
8
7
1
8
7
6
5 ALUMINIUM HOOD (2mm)
4 ITEM 1 2 3 4 5 6 7342
3 QTY 1 1 1 1 20 20 20
2 PARTS LIST PART NUMBER
1 DESCRIPTION F
COVER DISK F
HOOD BLIND FLANGE, PIPE FLANGE M8x20 WASHER m8 nut
225
ALUMINIUM HOOD (2mm)
E
117
FLANGE ALUMINIUM
SLOTTED MESH %50 OPEN AREA
E
607 660 710
A
SLOTTED MESH %50 OPEN AREA 4 FLANGE ALUMINIUM
BOLD&NUT D
5
9 COVER DISK5
D
DETAIL-AModel Size 16 18 20 24 30 36 42 48 Model Size 16 18 20
24 30 36 42 48 Throat Area m 0,134 0,17 0,209 0,301 0,467 0,677
0,907 1,191 Throat Area m 0,134 0,17 0,209 0,301 0,467 0,677 0,907
1,191 0,1 1393 1691 2073 3024 4180 5080 7136 10024 Relief
Performance Capacities (m/h) Total Pressure Drop in mbar 0,149
0,199 0,249 0,311 0,465 1741 2022 2277 2574 3135 2107 2447 2769
3118 3814 2582 3033 3390 3797 4638 3763 4383 4961 5530 6779 4910
5539 6142 6821 8359 6490 7671 8622 9633 11876 9175 10738 11944
13286 16497 12743 14951 16735 18774 23361 Intake Performance
Capacities (m/h) Total Pressure Drop in mbar 0,199 0,249 0,311
0,465 1799 2005 2210 2757 2185 2436 2684 3350 2659 2965 3267 4076
3602 4108 4625 5658 4383 5556 6252 7595 7012 8052 9056 11001 9390
10784 12127 14732 12338 14168 15933 19357 0,622 3670 4443 5379 7900
9625 13830 19454 26589
FLANGE ALUMINIUM
C
0,746 4052 4944 5969 8733 10571 15299 21832 28798
0,871 4434 5418 6556 9599 11516 16684 24143 30922
C
B
ALUMINIUM HOOD FLANGE ALUMINIUM
0,1 1276 1551 1888 2447 3007 4361 5839 7673
0,149 1572 1910 2324 3092 4010 5811 7781 10223PROJECT OWNER
0,622 3143 3819 4647 6517 8716 12624 16905 22211CHECKED
0,746 3451 4193 5102 7195 9385 13602 18217 23934
0,871 3714 4513 5491 7781 9888 14333 19195 25220
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
CENTER / FREE VENT DETAIL2
ATC.100.DWG.TYP.M.119PURCHASE NO :
X
8
7
1
8
7
6
5 ALUMINIUM HOOD
4 ITEM 1 2 3 4 5 6 7 8 9 10 QTY 1 1 1 19 18 1 1 1 1 17
F
BIRD SCREEN (MESH) SLOTTED
2 PARTS LIST PART NUMBER 24 RECTANGULAR NOZZLE 24'' CENTER FREE
VENT ASSEMBLY M8x20 m8 nut WASHER RECTANGULAR GASKET L.40x40x4-L
L.40x40x4-R L.40x40x4-L_MIR M8x35 ALUMINIUM HOOD
3
1 DESCRIPTION F
E200mm (Ref.)
BS.S. BOLTED DOME PANEL DOME PANEL
E
D 100
A610 810 BIRD SCREEN (MESH) BOLD&NUT FLANGE ALUMINIUM 100
BACKUP PLATE
D
C
C
ALUMINIUM HOOD
B
SLICONE COULK ALUMINIUM ANGLE
DOME PANEL M8 S.S. WASHER B BOLD&NUT M8x25 HX.HD.S.S
BOLD
DETAIL-A
DETAIL-B
ALUMINIUM ANGLE SILICONE SEALANT BETWEEN CURB&PANELBEFORE
FASTENING VENT CURB TO PANEL RUN A CONTINUOUS BEED OF SILICONE
SEALANT AROUND OUTSIDE PERIMETER OF HOLE PATTERN BETWEEN CURP AND
PANELTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
CUT PANEL OPENING 25mm FROM MATCH-DRILLED HOLES AS SHOWN
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
CENTER / FREE VENT ASSEMBLY2
ATC.100.DWG.TYP.M.120PURCHASE NO :
X
8
7
1
8
7
6
5 ALUMINIUM HOOD (2mm)
4
3
2
1
F225
F
FLANGE (ALUMINIUM)
E
117
SLOTTED MESH %50 OPEN AREA
342
E
A
C660 710 5 SLOTTED MESH %50 OPEN AREA
ALUMINIUM HOOD (2mm) FLANGE ALUMINIUM D COVER DISK SLOTTED MESH
%50 OPEN AREA
D
WELDING DETAILBOLD
DETAIL-A0,622 3670 4443 5379 7900 9625 13830 19454 26589 0,746
4052 4944 5969 8733 10571 15299 21832 28798 0,871 4434 5418 6556
9599 11516 16684 24143 30922
BOLD C
SLOTTED MESH %50 OPEN AREA
Model Size 16 18 20 24 30 36 42 48 Model Size 16 18 20 24 30 36
42 48
Throat Area m 0,134 0,17 0,209 0,301 0,467 0,677 0,907 1,191
Throat Area m 0,134 0,17 0,209 0,301 0,467 0,677 0,907 1,191
0,1 1393 1691 2073 3024 4180 5080 7136 10024
Relief Performance Capacities (m/h) Total Pressure Drop in mbar
0,149 0,199 0,249 0,311 0,465 1741 2022 2277 2574 3135 2107 2447
2769 3118 3814 2582 3033 3390 3797 4638 3763 4383 4961 5530 6779
4910 5539 6142 6821 8359 6490 7671 8622 9633 11876 9175 10738 11944
13286 16497 12743 14951 16735 18774 23361 Intake Performance
Capacities (m/h) Total Pressure Drop in mbar 0,199 0,249 0,311
0,465 1799 2005 2210 2757 2185 2436 2684 3350 2659 2965 3267 4076
3602 4108 4625 5658 4383 5556 6252 7595 7012 8052 9056 11001 9390
10784 12127 14732 12338 14168 15933 19357
C
B FLANGE ALUMINIUM
0,1 1276 1551 1888 2447 3007 4361 5839 7673
0,149 1572 1910 2324 3092 4010 5811 7781 10223PROJECT OWNER
0,622 3143 3819 4647 6517 8716 12624 16905 22211CHECKED
0,746 3451 4193 5102 7195 9385 13602 18217 23934
0,871 3714 4513 5491 7781 9888 14333 19195 25220
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
CENTER / FREE VENT INSTALLATION DETAIL3 2
ATC.100.DWG.TYP.M.121PURCHASE NO :
X
8
7
1
8
7 CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
6 ALUMINIUM FRAME COVER
5
4 ALUMINIUM FRAME COVER
3 SERIES S.S.304 SCREW/BOLT
2 8mm. TRIANGULAR CLEAR ACRYLIC LIGHTING PANEL (SKYLIGHT)
1
F
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB)
F
110
M8X25 BOLT CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) ALUMINIUM
DOME BEAM 150mm DEEP BEAM (TYPICAL)
E DOME PANEL DOME GUSSETS DOME BEAM
102
SECTION A - ADOME GUSSETS DOME PANELS/SHEETS AB BOLTS '' (M6)
DIA x 25 mm LONG W/WASHER & GASKET (304S.S. HHB) SKYLIGHT
E
DOME SHEET/PANEL
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB) DOME GUSSETS
D BATTEN BAR (ALUMINIUM)
D
ALUMINIUM BOX PROFILE
BC DOME GUSSETS
M8X25 BOLT M8X25 BOLT BATTEN CLAMP BAR C
BA
A
8mm. TRIANGULAR CLEAR ACRYLIC LIGHTING PANEL (SKYLIGHT)
FOAM TYPE ALUMINIUM BOX PROFILE B B
CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE)
DOME GUSSETS
SECTION B - BTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO
BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO
BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
TRIANGULAR SKYLIGHT DETAIL2
ATC100.DWG.TYP.M.122PURCHASE NO :
X
8
7
1
8 8mm. TRIANGULAR CLEAR ACRYLIC LIGHTING PANEL (SKYLIGHT) F
ALUMINIUM BOX PROFILE
7
6 SERIES S.S.304 SCREW/BOLT ALUMINIUM FRAME COVER FOAM TYPE
5
4 SILICONE SEALANT CONTINUOUS SEAL ALL AROUND PERIMETER
3 8mm. TRIANGULAR CLEAR ACRYLIC LIGHTING PANEL (SKYLIGHT)
2
1
F
SECTION B-B110
CONDENSATE GUTTER WITH DRAIN HOLES102
E
SERIES S.S.304 SCREW/BOLT DOME BATTEN
8,00
DOME PANEL/SHEET
E M8 X 25 BOLT 6061-T6 ALUMINIUM SUPPORT BEAM
SEAL DOME SHEET/PANEL
BACKING BAR (ALUMINIUM) D DOME GUSSETS 40X40X2 L PROFILE BACKING
(ALUMINIUM) CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) C DOME
BEAM/STRUT BATTEN CLAMP BAR AB BOLTS '' (M6) DIA x 25 mm LONG
W/WASHER & GASKET (304S.S. HHB) SKYLIGHT D
B
B
C
SKYLIGHT SPECIFICATIONB
A
DOME GUSSETS
A
SECTION A - A
1.) SKYLIGHT PANEL 8mm Thk. CLEAR ACRYLIC 2.) FRAME &
SUPPORT - MILL FINISH ALUMINIUM 3.) SKYLIGHT AREA - APPROXIMATELY
2m EACH 4.) TOTAL SKYLIGHT AREA - MIN 1m/100m PROJECT AREA
B CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE)
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
TRIANGULAR SKYLIGHT DETAIL2
ATC100.DWG.TYP.M.123PURCHASE NO :
X
8
7
1
8 246 F
7 747 342
6 160
5 490 245 245
4
3 ITEM 1 2 3 4 5 6 7328
2 QTY 1 1 1 1 2 2 2 PARTS LIST PART NUMBER BODY UPPER FLANGE
LOVER FLANGE SEAT (VACUUM) SEAT (PRESSURE) BEARING CAP
DIAPHRAGM
1 DESCRIPTION ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM
ALUMINIUM ALUMINIUM
F
328
7
E703 703
E 5
175
175
1 4 3200 200
1
DETAIL-A
DETAIL-B2 D
D 6
6''150#
342
C
C
490
5 7 B 246 753 342 165 1 3 4 B
PRESSURE VACUUM VENT SECTION VIEWTHIS DRAWING IS THE PROPERTY OF
AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR
WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
PRESSURE VACUUM VENT DETAILS TYPICAL3 2
ATC100.DWG.TYP.M.124PURCHASE NO :
X
8
7
1
8
7
6 NUT
5 PIPE
4 NUT GASKET DOME PANEL
3 ITEM 1 2 3 4 5 6 QTY 3 3 3 1 3 1
2 PARTS LIST PART NUMBER NODE PLATE TOP NODE PLATE LOW DOME BEAM
DOME SHEET/PANEL BATTEN BAR PRESSURE VACUUM VENT
1 DESCRIPTION ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM
-
WASHER
F
F
PRESSURE VACUUM VENT
WASHER BRACE ANGLE E BRACE ANGLE BOLD BOLT PRESSURE VACUUM VENT
E
DETAIL-BBOLT&NUT DOME PANEL D 6'' PIPE GASKET
DETAIL-C
D
DOME PANEL
B168.3 C
DOME PANEL BRACE ANGLE
DETAIL-DBRACE ANGLE PIPE C
BOLT&NUT
GASKET BOLT&NUT
PIPE BOLT&NUT
B BRACE ANGLE 160 BRACE ANGLE BRACE ANGLE 40
B
DETAIL-A
40
250
DETAIL-ETHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
ATC100.DWG.TYP.M.125
PRESSURE / VACUUM VENT ASSEMBLY TYPICAL3 2
PURCHASE NO :
X
8
7
1
8
7
6
5
4 COVER
3
2
1
COVER F CAMLOCK 6 3
ARM
ARM
F FLANGE BODY 3 ARM DIAPHRAGM
DETAIL - A2 E 5 8 COVER/DIAPHRAGM 6 CAMLOCK E
1
FLANGE BODY D COVER/DIAPHRAGM D
A4 CAMLOCK FLANGE BODY 3 CAMLOCK 6 1 5 2
8
DIAPHRAGM
FLANGE BODY C C
2 PARTS LIST ITEM QTY PART NUMBER 1 1 Flange Body 2 1 Cover 3 1
Arm 4 1 Diaphragm 5 1 Camlock Stud Bolt 6 1 Camlock 7 2 M10 Nut 8 1
M10x50 DESCRIPTION Aluminium Aluminium Aluminium Teflon Stainless
Steel Aluminium Stainless Steel Stainless Steel
ARM B
B
8
1
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
GAUGE HATCH DETAILS TYPICAL2
ATC100.DWG.TYP.M.126PURCHASE NO :
X
8
7
1
8
7
6
5 NUT
4
3 NUT WASHER GASKET
2 FLANGE
1
GAUGE HATCH F
WASHER F
GASKET DOME PANEL BOLD&NUT
DOME SHEET
BACKING FRAME (ALUMINIUM)
M8 BOLT E BRACE ANGLE
BRACE ANGLE E
DETAIL - A - EXPLODEDBOLT
DETAIL - A - EXPLODED6'' PIPE BRACE ANGLE DOME PANEL D BATTEN
BAR (ALUMINIUM) DOME SHEET/PANEL
CIRCULAR FORMED TOP GUSSETS (NODE PLATE) GAUGE HATCH
D
DETAIL - A - ISOMETRICDOME PANEL
C
A168.3 BOLD&NUT BOLD&NUT
BRACE ANGLE
C PIPE
B DOME PANEL BRACE ANGLE BRACE ANGLE 40 168.3 250 40 CIRCULAR
FORMED BOTTOM GUSSETS (NODE PLATE)THIS DRAWING IS THE PROPERTY OF
AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR
WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
B
DETAIL-A
DETAIL-E
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
GAUGE HATCH ASSEMBLY TYPICAL3 2
ATC100.DWG.TYP.M.127PURCHASE NO :
X
8
7
1
8 MANWAY COVER F
7
6 MANWAY HANDLE
5
4
3 ITEM 1 2 3 4 5 6 7 QTY 3 3 3 1 33 33 3
2 PARTS LIST PART NUMBER GUSSET PLATE TOP GUSSET PLATE LOW DOME
BEAM DOME SHEET/PANEL WASHER M8 BOLT CLAMP
1 DESCRIPTION F
HEX NUT M8 WASHER (A8.4) MANWAY FRAME
ADOME SHEET/PANEL E MANWAY FRAME
MANWAY FRAME MANWAY FRAME
GASKET BRACE ANGLE DOME SHEET/PANEL BACKING FRAME (ALUMINIUM) E
M8 BOLT
GASKET DOME SHEET DOME SHEET /PANEL D BRACE ANGLE
BRACE ANGLE
DETAIL - A - EXPLODED DETAIL - A - ISOMETRIC DETAIL - ACIRCULAR
FORMED TOP GUSSETS (NODE PLATE) MANWAY LIT BATTEN BAR (ALUMINIUM)
MANWAY LIT (OPENS 180) D BATTEN BAR (ALUMINIUM) MANWAY LATCH
(LOCKAD)
MANWAY HANDLE
C
C
DOME SHEET DOME SHEET/PANEL MANWAY FRAME B MANWAY FRAME MANWAY
HANDLE CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) ALUMINIUM DOME
BEAM 150mm DEEP BEAM (TYPICAL) B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
MANHOLE / HATCH COVER2
ATC100.DWG.TYP.M.128PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
110,00
F
MANWAY LIT
GASKET DOME SHEET MANWAY LATCH (LOCKAD)
F
873,00
BRACE ANGLE BACKING FRAME (ALUMINIUM) BODY
BODY
E
DETAIL - A
E
814,00
DOME SHEET/PANEL
ACIRCULAR FORMED TOP GUSSETS (NODE PLATE)
CIRCULAR FORMED TOP GUSSETS (NODE PLATE) D MANWAY LIT MANWAY
HANDLE
D DOME SHEET/PANEL
MANWAY FRAME MANWAY FRAME
MANWAY HANDLE
C CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE)
C
BODY
B
CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) DOME SHEET/PANEL
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
MANHOLE / HATCH COVER (ELEVATED)3 2
ATC100.DWG.TYP.M.129PURCHASE NO :
X
8
7
1
8 6'' PIPE F
7
6 NUT
5
4PIPE (BY OTHERS)
3Code DD101 Pipe Boot #1 Pipe Boot #2 Pipe Boot #3 Pipe Boot #4
Pipe Boot #5 Pipe Boot #6 Pipe Boot #7 Pipe Boot #8 Pipe Boot #9
5-65 45-80 5-127 73-160 108-190 125-230 150-280 175-330 254-483
2Description Pipe Size Metric Pipe Size Imperial 1/4"- 2 1/2" 1
3/4"-3 1/4" 1/4"-5" 3"-6 1/4" 4 1/4"-7 1/2" 5"-9" 6"-11" 7"-13"
10"-19" Base mm 137x137 177x177 218x218 284x284 365x365 365x365
453x453 453x453 685x685 Inch 39" 64" 69 1/2" 85 3/4" 111 3/4" 143
1/2" 178 1/2" 178 1/2" 269 3/4"
1Material EPDM EPDM EPDM EPDM EPDM EPDM EPDM EPDM EPDM
RETROFIT PIPE FLASHING (EPDM) RIVITED TO DOME PANEL
DD102 DD103 DD104
F
FLANGE DOME PANELSILICON SEAL ALL AROUND
RUBBER
DD105 DD106 DD107
BOLD (M6)
DETAIL-DE FLANGEPIPE (BY OTHERS)
DD108 DD109
E
EPDM WILL WITHSTAND CONSTANT TEMPERARURES AT THE ROOFLINE -50C
(122F) TO 115C (239F) & UP TO 150C (302F) INTERMITTENTLYDOME
PANEL
NUT RUBBER WASHER
BRUBBER D 6'' PIPE 168,3 (6'' PIPE) DOME PANEL FLANGE
F
D
PIPE BOOT SECTION
BRACE ANGLE BOLD&NUT
DETAIL-CBOLD C 168,3 30 305 365 RUBBER FLANGE B 30
DOME PANEL PIPE BOOT PIPE C
DETAIL-EEASILY CUSTOMIZED PIPE OPENING NINE DIFFERENT SIZE FIT
PIPES (1/4''-19'') TOUGH ULTRAVIOLET RESISTANT ''EPDM'' RUBBER
CARRIES THE BEST GUARANTEE IN THE INDUSTRY SQUARE FLANGE DESIGN
ADAPTS TO ANY ROOFING MATERIAL SEALS TIGHTLY WITH SILICONE SEALANT
AND STANDARD ROOFING FASTERNERS
DETAIL-B
ALUMINIUM BASE BENDS TO FORM A PERFECT SEAL WITH ANY CONTOUR
SURFACE IRREGULARITIES OR ROOF PITCH
B
BOLD&NUT BRACE ANGLE FLANGE
DETAIL-A
RUBBER SECTION VIEWTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS
NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT
OR TO BE MISUSED IN ANY WAY.
DETAIL-FPROJECT OWNER CHECKED APPROVED DATEDOCUMENT NO :
REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
PIPE BOOT DETAIL2
ATC.100.DWG.TYP.M.130PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
DOOR COVER
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
HANDLE F COVER DOOR WELL
CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) E
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
DOME SHEET/PANEL
M8 x 25 BOLT SEAL E BACKING BAR (ALUMINIUM)
SECTION A-ADOME GUSSETS
DOME SHEET(PANEL (1,2mm) AB BOLTS '' (M6) DIA x 25 mm LONG
W/WASHER & GASKET (304S.S. HHB) DOME GUSSETS
AB BOLTS '' (M6) DIA x 25 mm LONG W/WASHER & GASKET (304S.S.
HHB)
DOME SHEET(PANEL (1,2mm) D
D
C
C
DOME GUSSETS
A
ACIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE) ALUMINIUM DOME BEAM
150mm DEEP BEAM (TYPICAL) DOME GUSSETS
B
BATTEN CLAMP BAR DOME GUSSETS CIRCULAR FORMED BOTTOM GUSSETS
(NODE PLATE)THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
B
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
DOOR SECTION TYPICAL2
ATC100.DWG.TYP.M.131PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2 FLANGE
1
F79 n2 ,4 0
5
FLANGE
F
PIPE
PIPE WELDING
WELDING
REINFORCING PAD
DETAIL-G
FLANGE
E
E
FLANGE
279,4 D 241,310
D
PIPE
FLANGE
22
G
WELDING NOZZLE PAD
NOZZLE PAD C PIPE500
C NOZZLE PAD
DOME SURFACE
DETAIL-E
34,6 2
DOME SURFACE B BOLD&NUT
B
E168.3
GASKET
D
DETAIL-DTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
6'' TYPICAL NOZZLE2
ATC100.DWG.TYP.M.132PURCHASE NO :
X
8
7
1
8n
7290 2 ,9
6
5
4
3 FLANGE
2
1
8,4
F
5
34 n
F FLANGE
PIPE
AE
AE
FLANGE
REINFORCING PAD
FLANGE
342,90 298,45
WELDING
C22,3 D NOZZLE PAD D
WELDING5,00
FLANGE
500,00
C
22,3 8'' PIPE 8'' PIPE
10,00
8'' PIPE WELDING NOZZLE PAD
C
DETAIL - C B
GASKET
DOME SURFACE B BOLTS & NUTS 219,10 B
SECTION A - A
DETAIL - BTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
8'' TYPICAL NOZZLE2
ATC100.DWG.TYP.M.133PURCHASE NO :
X
8
7
1
8n25
7 FLANGE
6
5
4
3
2
1
,40
F
n
36 1,9 5
06, n4
40
FLANGE
F
FLANGE 10'' PIPE
E
A
AWELDING NOZZLE PAD
E
10'' PIPE 406,40 361,95 D 25,4 FLANGE
D
CNOZZLE PAD WELDING FLANGE10,00 5,00
PIPE C500,00
25,40 C PIPE WELDING NOZZLE PAD GASKET
B
DETAIL - C
DOME SURFACE B BOLTS & NUTS B
DETAIL - BSECTION A - ATHIS DRAWING IS THE PROPERTY OF AKTEK. IT
IS NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN
CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
10'' TYPICAL NOZZLE2
ATC100.DWG.TYP.M.134PURCHASE NO :
X
8
7
1
8n3
75,05
6
5
4 24'' FLANGE
3
2
1
F
n
FLANGE12 n8 ,8 0
74
9,3
F FLANGE 24'' PIPE
0
WELDING E E
A
A
NOZZLE PAD
WELDING D 24'' FLANGE 812,80 35,0512,00 6,00
24'' FLANGE NOZZLE PAD
D
749,30
C24'' PIPE
24'' PIPE 24'' PIPE C NOZZLE PAD GASKET
C600,00
DETAIL - C B
WELDING
24'' PIPE B
DOME SURFACE B BOLTS & NUTS
610,00
SECTION A - A
DETAIL - BTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
24'' TYPICAL NOZZLE2
ATC100.DWG.TYP.M.135PURCHASE NO :
X
8
7
1
8
7 S.S.304 M10 x 40 BOLT
6
5 SAFETY POLE COVER 1'' Thk. ROUND PLATE 6061-T6 ALUMINIUM (M10
SCREWED)
4
3
2
1
SAFETY POLE COVER 1'' Thk. ROUND PLATE 6061-T6 ALUMINIUM (M10
SCREWED)
S.S.304 M10 x 40 BOLT F
F 4'' x '' mm Thk PIPE (10'' LONG) 6061 ALUMINIUM 4'' x '' mm
Thk PIPE (10'' LONG) 6061 ALUMINIUM
WELDED TO THE PLATE (INSIDE AND OUTSIDE)280,00
FIELD APPLY (*) SILICONE SEALANT CENTER HUB COVER FIELD APPLY
(*) SILICONE SEALANT BATTEN HUB CLIPS UPPER NODE PLATE DOME PANEL
E
E
CENTER HUB COVER
D BATTEN HUB CLIPS
D
LOW NODE PLATE
SILICONE SEALANT BETWEEN GUSSET PLATE AND PANEL AT ENDS OF
BATTEN BAR M10x60 LG. HH W/NUTS (S.S.) LOCKED ON TO STANDART NODE
PLATE
4'' DIA CENTER PIN DETAILC
M10x60 LG. HH W/NUTS (S.S.) LOCKED ON TO STANDART NODE PLATE
WELDED TO THE PLATE (INSIDE AND OUTSIDE) C
B
1.) NODE PLATE SUPPLIED EITH 11 HOLE 2.) PAINTERS PIN IS
DESIGNED TO SUPPORT A 5000 LB LOAD SUSPENDED OVER THE EDGE OF THE
DOME 3.) SHIP PLATE ASSEMBLED WITH STUD, NUTS, & WASHERS SHOP
INSTALLED TO INSURE. THE CORRECT LENGTH OF THREAD ENGAGEMENT (NO
CAULK) AND TO INSURE THAT COVER PLATE IS IN PLACE DURING DOME
ERECTION. * SILICONE SEALANT FIELD APPLIED TO THE HUB COVER FLANGE,
THE TOP OF THE PIPE AND AROUND THE HOLE IN THE HUB COVER.
LOW NODE PLATE SILICONE SEALANT BETWEEN GUSSET PLATE AND PANEL
AT ENDS OF BATTEN BAR
NOTE;EYEBOLT FOR DOME ACCESS MAINTENANCE ONLY BY QUALIFIED
PERSONNEL. EYEBOLT RATED FOR OSHA FALL PROTECTION - MUST BE
INSPECTED OUR REPLACED AFTER FALL OR OTHER SHOCK LOADING. REMOVE
ANY TEMPORARY SAFETY LINE IMMEDIATELY AFTER USE.THIS DRAWING IS THE
PROPERTY OF AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED
WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
B
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
CENTER SAFETY LINE SUPPORT2
ATC100.DWG.TYP.M.136PURCHASE NO :
X
8
7
1
8
7
6
5 DOME SHEET(PANEL (1,2mm)
4
3
2
1
'' S.S. EYEBOLT W/(2) NUTS & WASHERS (SEE NOTE)
CIRCULAR HUB COVER F
F
'' S.S. EYEBOLT W/(2) NUTS & WASHERS (SEE NOTE) SILICONE
SEALANT AROUND EACH GUSSET COVER DOME APEX GUSSET
HUB COVER CLIPS E E
D
D
CIRCULAR FORMED TOP GUSSETS (NODE PLATE) CIRCULAR FORMED BOTTOM
GUSSETS (NODE PLATE)
C
NOTE;EYEBOLT FOR DOME ACCESS MAINTENANCE ONLY BY QUALIFIED
PERSONNEL. EYEBOLT RATED FOR OSHA FALL PROTECTION - MUST BE
INSPECTED OUR REPLACED AFTER FALL OR OTHER SHOCK LOADING. REMOVE
ANY TEMPORARY SAFETY LINE IMMEDIATELY AFTER USE.ALUMINIUM DOME BEAM
150mm DEEP BEAM (TYPICAL)
C
SILICONE SEALANT BETWEEN GUSSET PLATE AND PANEL AT ENDS OF
BATTEN BAR
B
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
S.S. EYEBOLT AT DOME APEX2
ATC100.DWG.TYP.M.137PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
HUB COVER
F
DOME SHEET(PANEL (1,2mm) HUB COVER CLIPS TOP GUSSET
E BOTTOM GUSSET FIELD DRILL (11mm) DIA. HOLE & INSTAL '' x
2'' S.S. EYEBOLT TO BOTTOM GUSSET WITH (2)NUTS AND (1) WASHER CABLE
CLAMP D
E
D
ANTI ROTATION CABLE (BY OTHERS) SILICONE SEALANT BETWEEN HUB
COVER AND PANEL CORNER BATTEN BAR (ALUMINIUM) CIRCULAR FORMED
BOTTOM GUSSETS (NODE PLATE) CIRCULAR FORMED TOP GUSSETS (NODE
PLATE)
C
C
NOTE:
LOCATE @ XX GUSSETS FOR TOTAL APPLIET LOAD = 38,7 kN LOAD @ EACH
CONNECTION = 1,21 kNB ALUMINIUM DOME BEAM 150mm DEEP BEAM
(TYPICAL)
SILICONE SEALANT BETWEEN GUSSET PLATE AND PANEL AT ENDS OF
BATTEN BAR
FIELD DRILL (11mm) DIA. HOLE & INSTAL '' x 2'' S.S. EYEBOLT
TO BOTTOM GUSSET WITH (2)NUTS AND (1) WASHER
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
EYEBOLT CONNECTION & INSTALLATION DETAIL FOR IFR CABLE3
2
ATC100.DWG.TYP.M.138PURCHASE NO :
X
8
7
1
8
7
6
5 S.S.316 TOP PLATE (by Others)
4
3
2
1
F
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
F S.S.316 TOP PLATE (by Others)
DOME SHEET/PANEL
E
BATTEN BAR (ALUMINIUM)
E
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) S.S.316 TOP PLATE
(by Others)
ALUMINIUM FLANGE ASSEMBLY (by ATECO) FOR FLAME DETECTOR (by
Others)
D
BATTEN BAR (ALUMINIUM) DOME SHEET/PANEL CIRCULAR FORMED BOTTOM
GUSSETS (NODE PLATE) BATTEN BAR (ALUMINIUM)
D
C ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) MATCH DRILL 10mm
DIA HOLES & USE ALUMINIUM LOCK BOLTS AB BOLTS '' (M6) DIA x 25
mm LONG W/WASHER & GASKET (304S.S. HHB) B DOME SHEET/PANEL
ALUMINIUM FLANGE ASSEMBLY (by ATECO) FOR FLAME DETECTOR (by
Others)
C
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
24'' FLAME DETECTOR FLANGE ASSEMBLY3 2
ATC100.DWG.TYP.M.139PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
S.S. HATCH LID HOLDOWN EYE-BOLT
F
S.S. NUT & 1 '' WASHER
BATTEN BAR
E
E
SKIN PANEL/DOME SHEET
D
D
BATTEN BEAM
INSTALLATION PROCEDURE: 1 OPEN HATCH LID AND DETERMINE PROPER
LOCATION FOR ''HATCH LID HOLDOWN.''
C
2 DRILL ONE '' HOLE DOWN THROUGH THE BATTEN BAR OR SKIN PANEL.
SKIP TO STEP 4 FOR LAPPED DOMES. 3 APPLY A FEW DROPS OF MOTOR OIL
ON THE THREAD OF A '' BOLT (#14 FASTENER) AND IMPACT BOLT INTO BEAM
GROOVE. THE BOLT WILL FORM THREADS IN THE GROVE OF THE ALUMINIUM
BEAM. 4 REMOVE THE '' BOLT AND APPLY A GENEROUS AMOUNT OF SILICONE
CAULC AROUND THE '' BOLT HOLE. THIS WILL INSURE THAT THE WATHER
-TIGHT INTERGRITY OF THE DOME IS MAINTAINED WHEN INSTALLING THE
''HATCH LID HOLDOWN.'' 5 SCREW THE S.S. EYEBOLT IN THE PRE-THREAD
GROOVE UNTIL THE EYEBOLT BOTTOMS THE OUT AND LOCKS DOWN TIGHT W/
S.S. NUT AND WASHER.THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS
NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT
OR TO BE MISUSED IN ANY WAY.
C
B
B
BATTEN INSTALLATIONFOR ENCLOSED-SEAL BATTEN
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HATCH LID HOLD-DOWN INSTALLATIONENCLOSED-SEAL BATTEN 3 2
ATC100.DWG.TYP.M.149PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
S.S. HATCH LID HOLDOWN EYE-BOLT
F
S.S. NUT & 1 '' WASHER
BATTEN BAR
E
E
SKIN PANEL/DOME SHEET
D
D
BATTEN BEAM
INSTALLATION PROCEDURE: 1 OPEN HATCH LID AND DETERMINE PROPER
LOCATION FOR ''HATCH LID HOLDOWN.''
C
2 DRILL ONE '' HOLE DOWN THROUGH THE BATTEN BAR OR SKIN PANEL.
SKIP TO STEP 4 FOR LAPPED DOMES. 3 APPLY A FEW DROPS OF MOTOR OIL
ON THE THREAD OF A '' BOLT (#14 FASTENER) AND IMPACT BOLT INTO BEAM
GROOVE. THE BOLT WILL FORM THREADS IN THE GROVE OF THE ALUMINIUM
BEAM. 4 REMOVE THE '' BOLT AND APPLY A GENEROUS AMOUNT OF SILICONE
CAULC AROUND THE '' BOLT HOLE. THIS WILL INSURE THAT THE WATHER
-TIGHT INTERGRITY OF THE DOME IS MAINTAINED WHEN INSTALLING THE
''HATCH LID HOLDOWN.'' 5 SCREW THE S.S. EYEBOLT IN THE PRE-THREAD
GROOVE UNTIL THE EYEBOLT BOTTOMS THE OUT AND LOCKS DOWN TIGHT W/
S.S. NUT AND WASHER.THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS
NOT TO BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT
OR TO BE MISUSED IN ANY WAY.
C
B
B
BATTEN INSTALLATIONFOR ENCLOSED-SEAL BATTEN
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
HATCH LID HOLD-DOWN INSTALLATIONENCLOSED-SEAL BATTEN 3 2
ATC100.DWG.TYP.M.149PURCHASE NO :
X
8
7
1
8 405 F ARM 3
7
6 HANDLE COVER 2
5 240
4 656 176 240
3 ITEM 1 3 6
2 QTY 1 1 20 PARTS LIST PART NUMBER BODY ARM BOLT
1 DESCRIPTION SS316 SS316 F SS316
OPENING PRESSURE: XX mbar105
En813
120
225
BODY
1
BODY 610n813
E
FRONT VIEW LEFT VIEW1 2 COVER 2
D 3 COVER ARM
D
813
C
C
3 B ARM
1 B
BODY
TOP VIEWTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE
TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE
MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
EMERGENCY VENT DETAIL TYPICAL2
ATC100.DWG.TYP.M.150PURCHASE NO :
X
8
7
1
8
7 778 600
6
5
4
3
2
1
ARM F
COVER
ARM
F
450
BODY BODY
E895 895 1028
583
E
220
CONE445
COVER BODY
225
D
PIPE
D
6'' FLANGE
168 ARM
636
230
B
176
230
C
C
B BODY
SECTION VIEWTHIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO
BE TRACED, COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO
BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4
GAUGE POLE BASIN DETAIL TYPICAL3 2
ATC100.DWG.TYP.M.152PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
'' DIA. x 2 '' GRADE 8 OR A490 BOLT 1'' DIA. HOLE 2'' FROM END
OF LIFTING LUG
F
ADOME BEAM/STRUT E
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
REINFORCED DISK ORIENT LIFTING LUGS TO ALIGN WITH LIFTING
BRIDLES. (NOTE; THIGTNESS PRIOR TO LIFTING DOME.)
E
D REINFORCED DISK
D
DOUBLE NUT
C
REINFORCED DISK FOR NUT CIRCULAR FORMED BOTTOM GUSSETS (NODE
PLATE)
C
SECTION A-A
B
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)
B
A
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
LIFTING LUG INSTALLATION2
ATC100.DWG.TYP.M.164PURCHASE NO :
X
8
7
1
8
7
6
5
4
3
2
1
F
Measure outside pipe diameter and trim cone exactly where
indicated. For square pipes add 30%.
Fasten flashing with washered self drilling screws. As per
diagram, secure clip by placing a fastener either side of the clip
first.
F
E
E
With clip in down-stream position, tension top of cone around
pipe and engage metal teeth in opposing pockets.D
Apply sealant to top of crimp closure and any other potential
leak areas. (refer to page 13 for silicone types).D
C
To assist in locating clip into pocket, place hand behind the
seam. Fasten clip with pliers or multigrips, working from top to
base. Do not overcrimp.
Code RF801G RF802G RF803G
Material Gray EPDM Gray EPDM Gray EPDM
Base-mm 160 273 369
Pipe-mm 20-70 50-185 85-255 C
B
Apply a liberal bead of neutral silicone sealant to the
underside of Dektite base and press to contour of sheet
profile.
B
EPDM withstands temperatures from -50C - 115C and up to 150C
intermittently.
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNERA
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A
DOME-ROOF-SEAL6 5 4 3
DEKTITE RETROFIT ORIGINAL INSTALLATION INSTRUCTIONS2
ATC100.DWG.TYP.M.165PURCHASE NO :
0
X1
8
7
8
7
6
5
4
3
2
1
F
Cut Dektite cone where indicated for the relevant pipe size
F
E
E
Slide Dektite flashing down over pipe. Water can be used as a
lubricant
D
D
Apply neutral cure silicone sealant on underside of flange
C
C
Press pipe flashing into contours of roof panelB
Fasten flashing to surface with self-tapping or self drilling
screws; or selected pop rivets
B
THIS DRAWING IS THE PROPERTY OF AKTEK. IT IS NOT TO BE TRACED,
COPIED OR PUBLISHED WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED
IN ANY WAY.
PROJECT OWNERA
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A
DOME-ROOF-SEAL6 5 4
DEKTITE INSTALLATION INSTRUCTIONS3 2
ATC100.DWG.TYP.M.166PURCHASE NO :
0
X1
8
7
8
7
6
5
4 6,4mm ('') SELF-TAPPING SCREWS
3
2
1
F
4,8mm (3/16'') S.S. WIRE ROPE BREAKING STRENGTH 1878kg
(3700lb)
F ALUMINIUM HOUSING FOR CABLE STORAGE 4,8mm (3/16'') S.S. WIRE
ROPE BREAKING STRENGTH 1878kg (3700lb)
COPPER STOP SLEEVES (NOMINAL PULL-OUT STRENGTH 488kg - (1075lb)
EACH) PERMANENT WASHER E
E
S.S. ROPE CLIP
D
TOP GUSSET WITH 12,7mm ('') HOLE AT CENTER & 11,1mm (7/16'')
HOLE FOR EYEBOLT HUB COVER CLIPS
D
ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL) C 11,1mm (7/16'')
HOLE FOR EYEBOLT 12,7mm (1/2'') HOLE AT CENTER (CHAMFER) 9,5mm x
38,1mm (3/8'' x 1 1/2'') S.S. EYEBOLT WITH S.S. WASHER AND (2) S.S.
NUTS CIRCULAR FORMED BOTTOM GUSSETS (NODE PLATE)8
C
VERTICAL LINE FROM GUSSET TO IFR B
MAX. ANGLE FOR IFR ALUMINIUM DOME BEAM 150mm DEEP BEAM (TYPICAL)
B
CIRCULAR FORMED TOP GUSSETS (NODE PLATE)THIS DRAWING IS THE
PROPERTY OF AKTEK. IT IS NOT TO BE TRACED, COPIED OR PUBLISHED
WITHOUT THEIR WRITTEN CONSENT OR TO BE MISUSED IN ANY WAY.
PROJECT OWNER
CHECKED APPROVED DATEDOCUMENT NO : REVISION NO
A
Geodesic DomeREV. DESCRIPTION REVISIONS NAME DATE
CLIENTDESCIPTION :
A0
DOME-ROOF-SEAL6 5 4 3
IFR CABLE HOUSING ASSEMBLY2
ATC100.DWG.TYP.M.167PURCHASE NO :
X
8
7
1