s B31.3 1/2" s/40 & Std. - 0.109" Wall PENETRAMETER SELECTION Note: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest. Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3 Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3 Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172" CRACKS AND LACK OF FUSION None Allowed INCOMPLETE PENETRATION Normal Service Girth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld. Longitudinal Groove: None allowed Severe Cyclic Girth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATION Normal Service Max Individual Length: 0.218 Max Individual Width: 0.055" Max Cumulative Length: 0.436 in 6" of weld Severe Cyclic Conditions Max Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w. UNDERCUTTING Normal Services: Not a factor for normal service Severe Cyclic: Zero allowed CONCAVE ROOT SURFACE (SUCK-UP) Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall INTERNAL POROSITY Relevant Indication: 0.012 Normal Services: Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036" Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weld Max group length of Aligned Internal Porosity: 0.250" Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218" Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0" Max number of relevant internal porosity in a 6" length of of weld = 12 Severe Cyclic: Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036" Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weld. Max group length of Aligned Internal Porosity: 0.250" Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218 Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0" Max number of relevant internal porosity in a 6" length of weld = 12
86

Asme b31.3 Acceptance Rt Tabulated

Jan 15, 2016

Download

Documents

Walter Trajada

Asme b31.3 Acceptance Rt Tabulated, NDT, NDE, RT
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Asme b31.3 Acceptance Rt Tabulated

s

B31.31/2" s/40 & Std. - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218 Max Individual Width: 0.055" Max Cumulative Length: 0.436 in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weld.Max group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 2: Asme b31.3 Acceptance Rt Tabulated

s

B31.31/2 s/80 & Extra Strong - 0.147" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.210"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.294" Max Individual Width: 0.074" Max Cumulative Length: 0.588" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.049" Max Individual Width: 0.049" Max Cumulative Length: 0.147" in 1.764" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max Sum of diameters of Aligned Porosity: 0.147" in a 1.764" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.294"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max sum of diameters of Aligned Porosity: 0.147" in a 1.764" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.294"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 3: Asme b31.3 Acceptance Rt Tabulated

s

B31.31/2" s/160 - 0.188" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.251"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.376" Max Individual Width: 0.094" Max Cumulative Length: 0.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.063" Max Individual Width: 0.063" Max Cumulative Length: 0.188" in 2.256" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max Sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weld.Max group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 4: Asme b31.3 Acceptance Rt Tabulated

s

B31.33/4" s/40 & Std. - 0.113" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.176"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.226" Max Individual Width: 0.057" Max Cumulative Length: 0.452" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.038" Max Individual Width: 0.038" Max Cumulative Length: 0.113" in 1.356" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.028" Max Size of Isolated Internal Porosity: 0.038"Max Sum of diameters of Aligned Porosity: 0.113" in a 1.356" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.226"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.028" Max Size of Isolated Internal Porosity: 0.038"Max sum of diameters of Aligned Porosity: 0.113" in a 1.356" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.226"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 5: Asme b31.3 Acceptance Rt Tabulated

s

B31.33/4" s/80 & Extra Strong - 0.154" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.217"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.308" Max Individual Width: 0.077" Max Cumulative Length: 0.616" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.051" Max Individual Width: 0.051" Max Cumulative Length: 0.154" in 1.848" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max Sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 6: Asme b31.3 Acceptance Rt Tabulated

s

B31.33/4" s/160 - 0.219" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.282"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.438" Max Individual Width: 0.110" Max Cumulative Length: 0.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.219" in 2.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.219" in a 2.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.438"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.219" in a 2.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.438"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 7: Asme b31.3 Acceptance Rt Tabulated

s

B31.33/4" XX Strong - 0.308" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.433"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.616" Max Individual Width: 0.125" Max Cumulative Length: 1.232" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.103" Max Individual Width: 0.094" Max Cumulative Length: 0.308" in 3.696" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031"

Normal Services:Max Size of Random Internal Porosity: 0.116" Max Size of Isolated Internal Porosity: 0.154"Max Sum of diameters of Aligned Porosity: 0.462" in a 3.696" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.924"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.077" Max Size of Isolated Internal Porosity: 0.103"Max sum of diameters of Aligned Porosity: 0.308" in a 3.696" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.616"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 8: Asme b31.3 Acceptance Rt Tabulated

s

B31.31" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 9: Asme b31.3 Acceptance Rt Tabulated

s

B31.31" s/40 & Std. - 0.133" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.196"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.266" Max Individual Width: 0.067" Max Cumulative Length: 0.532" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.044" Max Individual Width: 0.044" Max Cumulative Length: 0.133" in 1.596" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.033" Max Size of Isolated Internal Porosity: 0.044"Max Sum of diameters of Aligned Porosity: 0.133" in a 1.596" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.266"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.033" Max Size of Isolated Internal Porosity: 0.044"Max sum of diameters of Aligned Porosity: 0.133" in a 1.596" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.266"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 10: Asme b31.3 Acceptance Rt Tabulated

s

B31.31" s/80 & Extra Strong - 0.179" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: ` 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.242"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.358" Max Individual Width: 0.090" Max Cumulative Length: 0.716" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.060" Max Individual Width: 0.060" Max Cumulative Length: 0.179" in 2.148" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max Sum of diameters of Aligned Porosity: 0.179" in a 2.148" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.358"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max sum of diameters of Aligned Porosity: 0.179" in a 2.148" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.358"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 11: Asme b31.3 Acceptance Rt Tabulated

s

B31.31" s/160 - 0.250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.000 in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 12: Asme b31.3 Acceptance Rt Tabulated

s

B31.31" XX Strong - 0.358" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.483"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.716" Max Individual Width: 0.125" Max Cumulative Length: 1.432" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.119" Max Individual Width: 0.094" Max Cumulative Length: 0.358" in 4.296" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.134" Max Size of Isolated Internal Porosity: 0.179"Max Sum of diameters of Aligned Porosity: 0.537" in a 4.296" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.074"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.090" Max Size of Isolated Internal Porosity: 0.119"Max sum of diameters of Aligned Porosity: 0.358" in a 4.296" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.716"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 13: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.25" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 14: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.25" s/40 & Std. - 0.140" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.203"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.280" Max Individual Width: 0.070" Max Cumulative Length: 0.560" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.047" Max Individual Width: 0.047" Max Cumulative Length: 0.140" in 1.680" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.035" Max Size of Isolated Internal Porosity: 0.047"Max Sum of diameters of Aligned Porosity: 0.140" in a 1.680" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.280"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.035" Max Size of Isolated Internal Porosity: 0.047"Max sum of diameters of Aligned Porosity: 0.140" in a 1.680" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.280"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 15: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.25" s/160 - 0.250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 16: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.25" XX Strong - 0.382" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.507"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.764" Max Individual Width: 0.125" Max Cumulative Length: 1.528" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.127" Max Individual Width: 0.094" Max Cumulative Length: 0.382" in 4.584" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.143" Max Size of Isolated Internal Porosity: 0.191"Max Sum of diameters of Aligned Porosity: 0.573" in a 4.584" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.146"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.096" Max Size of Isolated Internal Porosity: 0.127"Max sum of diameters of Aligned Porosity: 0.382" in a 4.584" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.764"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 17: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.5" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218'Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 18: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.5" s/40 & /Std. - 0.145" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.208"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.290" Max Individual Width: 0.073" Max Cumulative Length: 0.580" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.048" Max Individual Width: 0.048" Max Cumulative Length: 0.145" in 1.740" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.036" Max Size of Isolated Internal Porosity: 0.048"Max Sum of diameters of Aligned Porosity: 0.145" in a 1.740" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.290"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.036" Max Size of Isolated Internal Porosity: 0.048"Max sum of diameters of Aligned Porosity: 0.145" in a 1.740" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.290"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 19: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.5" s/80 & Extra Strong - 0.200" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.263"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.400" Max Individual Width: 0.100" Max Cumulative Length: 0.800" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.067" Max Individual Width: 0.067" Max Cumulative Length: 0.200" in 2.400" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.050" Max Size of Isolated Internal Porosity: 0.067"Max Sum of diameters of Aligned Porosity: 0.200" in a 2.400" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.400"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.050" Max Size of Isolated Internal Porosity: 0.067"Max sum of diameters of Aligned Porosity: 0.200" in a 2.400" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.400"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 20: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.5" s/160 - 0.281" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.406"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.562" Max Individual Width: 0.125" Max Cumulative Length: 1.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.094" Max Individual Width: 0.094" Max Cumulative Length: 0.281" in 3.372" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.105" Max Size of Isolated Internal Porosity: 0.141"Max Sum of diameters of Aligned Porosity: 0.422" in a 3.372" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.843"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.070" Max Size of Isolated Internal Porosity: 0.094"Max sum of diameters of Aligned Porosity: 0.281" in a 3.372" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.562"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 21: Asme b31.3 Acceptance Rt Tabulated

s

B31.31.5" XX Strong - 0.400" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.525"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.800" Max Individual Width: 0.125" Max Cumulative Length: 1.600" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.133" Max Individual Width: 0.094" Max Cumulative Length: 0.400" in 4.800" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.150" Max Size of Isolated Internal Porosity: 0.200"Max Sum of diameters of Aligned Porosity: 0.600" in a 4.800" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.200"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.100" Max Size of Isolated Internal Porosity: 0.133"Max sum of diameters of Aligned Porosity: 0.400" in a 4.800" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.800"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 22: Asme b31.3 Acceptance Rt Tabulated

s

B31.32" s/40 & Std. - 0.154" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.217"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.308" Max Individual Width: 0.077" Max Cumulative Length: 0.616" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.051" Max Individual Width: 0.051" Max Cumulative Length: 0.154" in 1.848" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max Sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 23: Asme b31.3 Acceptance Rt Tabulated

s

B31.32" s/80 and Extra Strong - 0.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.281"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.436" Max Individual Width: 0.109" Max Cumulative Length: 0.872" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.218" in 2.616" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 24: Asme b31.3 Acceptance Rt Tabulated

s

B31.32" s/160 - 0.344" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.469"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.688" Max Individual Width: 0.125" Max Cumulative Length: 1.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.115" Max Individual Width: 0.094" Max Cumulative Length: 0.344" in 4.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.129" Max Size of Isolated Internal Porosity: 0.172"Max Sum of diameters of Aligned Porosity: 0.516" in a 4.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.032"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.086" Max Size of Isolated Internal Porosity: 0.115"Max sum of diameters of Aligned Porosity: 0.344" in a 4.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.688"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 25: Asme b31.3 Acceptance Rt Tabulated

s

B31.32" XX Strong - 0.436" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.561"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.872" Max Individual Width: 0.125" Max Cumulative Length: 1.744" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.145" Max Individual Width: 0.094" Max Cumulative Length: 0.436" in 5.232" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.218"Max Sum of diameters of Aligned Porosity: 0.654" in a 5.232" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.109" Max Size of Isolated Internal Porosity: 0.145"Max sum of diameters of Aligned Porosity: 0.436" in a 5.232" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.872"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 26: Asme b31.3 Acceptance Rt Tabulated

s

B31.33" s/10 - 0.120" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.240" Max Individual Width: 0.060" Max Cumulative Length: 0.480" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.040" Max Individual Width: 0.040" Max Cumulative Length: 0.120" in 1.440" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.013

Normal Services:Max Size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max Sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 27: Asme b31.3 Acceptance Rt Tabulated

s

B31.33" s/40 & Std. - 0.216" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.279"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.432" Max Individual Width: 0.108" Max Cumulative Length: 0.864" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.072" Max Individual Width: 0.072" Max Cumulative Length: 0.216" in 2.592" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.054" Max Size of Isolated Internal Porosity: 0.072"Max Sum of diameters of Aligned Porosity: 0.216" in a 2.592" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.432"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.054" Max Size of Isolated Internal Porosity: 0.072"Max sum of diameters of Aligned Porosity: 0.216" in a 2.592" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.432"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 28: Asme b31.3 Acceptance Rt Tabulated

s

B31.33" s/80 and Extra Strong - 0.300" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.425"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.600" Max Individual Width: 0.125" Max Cumulative Length: 1.200" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.100" Max Individual Width: 0.094" Max Cumulative Length: 0.300" in 3.600" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.113" Max Size of Isolated Internal Porosity: 0.150"Max Sum of diameters of Aligned Porosity: 0.450" in a 3.600" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.900"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.075" Max Size of Isolated Internal Porosity: 0.100"Max sum of diameters of Aligned Porosity: 0.300" in a 3.600" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.600"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 29: Asme b31.3 Acceptance Rt Tabulated

s

B31.33" s/160 - 0.438" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.563"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.876" Max Individual Width: 0.125" Max Cumulative Length: 1.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.146" Max Individual Width: 0.094" Max Cumulative Length: 0.438" in 5.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.219"Max Sum of diameters of Aligned Porosity: 0.657" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.314"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.110" Max Size of Isolated Internal Porosity: 0.146"Max sum of diameters of Aligned Porosity: 0.438" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 30: Asme b31.3 Acceptance Rt Tabulated

s

B31.33" XX Strong - 0.600" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.756"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.200" Max Individual Width: 0.125" Max Cumulative Length: 2.400" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.200" Max Individual Width: 0.094" Max Cumulative Length: 0.600" in 7.200" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.225" Max Size of Isolated Internal Porosity: 0.300"Max Sum of diameters of Aligned Porosity: 0.900" in a 7.200" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.150" Max Size of Isolated Internal Porosity: 0.200"Max sum of diameters of Aligned Porosity: 0.600" in a 7.200" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 31: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" s/10 - 0.120" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.240" Max Individual Width: 0.060" Max Cumulative Length: 0.480" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.040" Max Individual Width: 0.040" Max Cumulative Length: 0.120" in 1.440" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.013

Normal Services:Max Size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max Sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 32: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" s/40 & Std. - 0.237" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.474" Max Individual Width: 0.119" Max Cumulative Length: 0.948" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.079" Max Individual Width: 0.079" Max Cumulative Length: 0.237" in 2.844" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.059" Max Size of Isolated Internal Porosity: 0.079"Max Sum of diameters of Aligned Porosity: 0.237" in a 2.844" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.474"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.059" Max Size of Isolated Internal Porosity: 0.079"Max sum of diameters of Aligned Porosity: 0.237" in a 2.844" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.474"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 33: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" s/80 and Extra Strong - 0.337" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.462"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.674" Max Individual Width: 0.125" Max Cumulative Length: 1.348" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.112" Max Individual Width: 0.094" Max Cumulative Length: 0.337" in 4.044" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.126" Max Size of Isolated Internal Porosity: 0.169"Max Sum of diameters of Aligned Porosity: 0.506" in a 4.044" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.011"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.084" Max Size of Isolated Internal Porosity: 0.112"Max sum of diameters of Aligned Porosity: 0.337" in a 4.044" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.674"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 34: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" s/120 - 0.438" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.563"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.876" Max Individual Width: 0.125" Max Cumulative Length: 1.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.146" Max Individual Width: 0.094" Max Cumulative Length: 0.438" in 5.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.219"Max Sum of diameters of Aligned Porosity: 0.657" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.314"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.110" Max Size of Isolated Internal Porosity: 0.146"Max sum of diameters of Aligned Porosity: 0.438" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 35: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" s/160 - 0.531" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.687"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.062" Max Individual Width: 0.125" Max Cumulative Length: 2.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.177" Max Individual Width: 0.094" Max Cumulative Length: 0.531" in 6.372" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.199" Max Size of Isolated Internal Porosity: 0.266"Max Sum of diameters of Aligned Porosity: 0.797" in a 6.372" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.133" Max Size of Isolated Internal Porosity: 0.177"Max sum of diameters of Aligned Porosity: 0.531" in a 6.372" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 36: Asme b31.3 Acceptance Rt Tabulated

s

B31.34" XX Strong - 0.674" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.830"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.348" Max Individual Width: 0.125" Max Cumulative Length: 2.696" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.225" Max Individual Width: 0.094" Max Cumulative Length: 0.674" in 8.008" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.337"Max Sum of diameters of Aligned Porosity: 1.011" in a 8.088" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.225"Max sum of diameters of Aligned Porosity: 0.674" in a 8.088" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 37: Asme b31.3 Acceptance Rt Tabulated

s

B31.36" s/10 = 0.134" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.197"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.268" Max Individual Width: 0.067" Max Cumulative Length: 0.536" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.045" Max Individual Width: 0.045" Max Cumulative Length: 0.134" in 1.608" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.034" Max Size of Isolated Internal Porosity: 0.045"Max Sum of diameters of Aligned Porosity: 0.134" in a 1.608" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.268"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.034" Max Size of Isolated Internal Porosity: 0.045"Max sum of diameters of Aligned Porosity: 0.134" in a 1.608" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.268"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 38: Asme b31.3 Acceptance Rt Tabulated

s

B31.36" s/40 & Std. - 0.280" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.405"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.560" Max Individual Width: 0.125" Max Cumulative Length: 1.120" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.093" Max Individual Width: 0.093" Max Cumulative Length: 0.280" in 3.360" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.105" Max Size of Isolated Internal Porosity: 0.140"Max Sum of diameters of Aligned Porosity: 0.420" in a 3.360" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.840"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.070" Max Size of Isolated Internal Porosity: 0.093"Max sum of diameters of Aligned Porosity: 0.280" in a 3.360" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.560"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 39: Asme b31.3 Acceptance Rt Tabulated

s

B31.36" s/80 & Extra Strong - 0.432" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.557"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.864" Max Individual Width: 0.125" Max Cumulative Length: 1.728" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.144" Max Individual Width: 0.094" Max Cumulative Length: 0.432" in 5.184" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.162" Max Size of Isolated Internal Porosity: 0.216"Max Sum of diameters of Aligned Porosity: 0.648" in a 5.184" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.108" Max Size of Isolated Internal Porosity: 0.144"Max sum of diameters of Aligned Porosity: 0.432" in a 5.184" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.864"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 40: Asme b31.3 Acceptance Rt Tabulated

s

B31.36" s/160 - 0.719" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.875"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.438" Max Individual Width: 0.125" Max Cumulative Length: 2.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.240" Max Individual Width: 0.094" Max Cumulative Length: 0.719" in 8.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.360"Max Sum of diameters of Aligned Porosity: 1.079" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.240"Max sum of diameters of Aligned Porosity: 0.719" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 41: Asme b31.3 Acceptance Rt Tabulated

s

B31.36" XX Strong - 0.864" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.020"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.728" Max Individual Width: 0.125" Max Cumulative Length: 3.456" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.288" Max Individual Width: 0.094" Max Cumulative Length: 0.864" in 10.368"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.296" in a 10.368" length of weldMax group length of Aligned Internal Porosity: 0.432"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.864" in a 10.368" length of weldMax group length of Aligned Internal Porosity: 0.288"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 42: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" s/10 - 0.148" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.211"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.296" Max Individual Width: 0.074" Max Cumulative Length: 0.592" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.049" Max Individual Width: 0.049" Max Cumulative Length: 0.148" in 1.776" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max Sum of diameters of Aligned Porosity: 0.148" in a 1.776" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max sum of diameters of Aligned Porosity: 0.148" in a 1.776" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 43: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" s/40 & Std. - 0.322" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.447"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.644" Max Individual Width: 0.125" Max Cumulative Length: 1.288" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.107" Max Individual Width: 0.094" Max Cumulative Length: 0.322" in 3.864" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.121" Max Size of Isolated Internal Porosity: 0.161"Max Sum of diameters of Aligned Porosity: 0.483" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.966"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.081" Max Size of Isolated Internal Porosity: 0.107"Max sum of diameters of Aligned Porosity: 0.322" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.644"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 44: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" s/80 & Extra Strong - 0.500" Wall

Penetrameter SelectionNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 45: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" s/120 - 0.719" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.875"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.438" Max Individual Width: 0.125" Max Cumulative Length: 2.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.240" Max Individual Width: 0.094" Max Cumulative Length: 0.719" in 8.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.360"Max Sum of diameters of Aligned Porosity: 1.079" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.240"Max sum of diameters of Aligned Porosity: 0.719" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 46: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" s/160 - 0.906" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.062"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.812" Max Individual Width: 0.125" Max Cumulative Length: 3.624" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.302" Max Individual Width: 0.094" Max Cumulative Length: 0.906" in 10.872"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.359" in a 10.872" length of weldMax group length of Aligned Internal Porosity: 0.453"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.906" in a 10.872" length of weldMax group length of Aligned Internal Porosity: 0.302"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 47: Asme b31.3 Acceptance Rt Tabulated

s

B31.38" XX Strong - 0.875" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.031"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.750" Max Individual Width: 0.125" Max Cumulative Length: 3.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.292" Max Individual Width: 0.094" Max Cumulative Length: 0.875" in 10.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.313" in a 10.5" length of weldMax group length of Aligned Internal Porosity: 0.438"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.875" in a 10.5" length of weldMax group length of Aligned Internal Porosity: 0.292"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 48: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" s/10 - 0.165" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.228"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.330" Max Individual Width: 0.083" Max Cumulative Length: 0.660" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.055" Max Individual Width: 0.055" Max Cumulative Length: 0.165" in 1.980" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.041" Max Size of Isolated Internal Porosity: 0.055"Max Sum of diameters of Aligned Porosity: 0.165" in a 1.980" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.330"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.041" Max Size of Isolated Internal Porosity: 0.055"Max sum of diameters of Aligned Porosity: 0.165" in a 1.980" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.330"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 49: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" s/40 & Std. - 0.365" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.490"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.730" Max Individual Width: 0.125" Max Cumulative Length: 1.460" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.122" Max Individual Width: 0.094" Max Cumulative Length: 0.365" in 4.380" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.137" Max Size of Isolated Internal Porosity: 0.183"Max Sum of diameters of Aligned Porosity: 0.548" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.095"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.091" Max Size of Isolated Internal Porosity: 0.122"Max sum of diameters of Aligned Porosity: 0.365" in a 4.380" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.730"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 50: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" s/80 - 0.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.750"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.188" Max Individual Width: 0.125" Max Cumulative Length: 2.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.198" Max Individual Width: 0.094" Max Cumulative Length: 0.594" in 7.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.223" Max Size of Isolated Internal Porosity: 0.297"Max Sum of diameters of Aligned Porosity: 0.894" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.149" Max Size of Isolated Internal Porosity: 0.198"Max sum of diameters of Aligned Porosity: 0.594" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 51: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 52: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" s/120 - 0.844" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.000"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.688" Max Individual Width: 0.125" Max Cumulative Length: 3.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.281" Max Individual Width: 0.094" Max Cumulative Length: 0.844" in 10.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.266" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.422"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.844" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.281"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 53: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" s/160 - 1.125" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.250" Max Individual Width: 0.125" Max Cumulative Length: 4.5" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.375" Max Individual Width: 0.094" Max Cumulative Length: 1.125" in 13.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.688" in a 13.5" length of weldMax group length of Aligned Internal Porosity: 0.563"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.125" in a 13.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 54: Asme b31.3 Acceptance Rt Tabulated

s

B31.310" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 55: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" s/10 - 0.180" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.243"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.360" Max Individual Width: 0.090" Max Cumulative Length: 0.720" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.060" Max Individual Width: 0.060" Max Cumulative Length: 0.180" in 2.160" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITY0.016

Normal Services:

Max Size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max Sum of diameters of Aligned Porosity: 0.180" in a 2.160" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.360"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max sum of diameters of Aligned Porosity: 0.180" in a 2.160" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.360"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 56: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 57: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" s/40 - 0.406" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.531"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.812" Max Individual Width: 0.125" Max Cumulative Length: 1.624" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.135" Max Individual Width: 0.094" Max Cumulative Length: 0.406" in 4.872"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.152" Max Size of Isolated Internal Porosity: 0.203"Max Sum of diameters of Aligned Porosity: 0.609" in a 4.872" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.102" Max Size of Isolated Internal Porosity: 0.135"Max sum of diameters of Aligned Porosity: 0.406" in a 4.872" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.812"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 58: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" s/80 - 0.688" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.844"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.376" Max Individual Width: 0.125" Max Cumulative Length: 2.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.229" Max Individual Width: 0.094" Max Cumulative Length: 0.688" in 8.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.344"Max Sum of diameters of Aligned Porosity: 1.032" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.229"Max sum of diameters of Aligned Porosity: 0.688" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 59: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 60: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 61: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" s/120 - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 62: Asme b31.3 Acceptance Rt Tabulated

s

B31.312" s/160 - 1.312" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.624" Max Individual Width: 0.125" Max Cumulative Length: 5.248" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.437" Max Individual Width: 0.094" Max Cumulative Length: 1.312" in 15.744"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.968" in a 15.744" length of weldMax group length of Aligned Internal Porosity: 0.656"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.312" in a 15.744" length of weldMax group length of Aligned Internal Porosity: 0.437"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 63: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" s/10 - 0.188" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.251"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.376" Max Individual Width: 0.094" Max Cumulative Length: 0.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.063" Max Individual Width: 0.063" Max Cumulative Length: 0.188" in 2.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max Sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 64: Asme b31.3 Acceptance Rt Tabulated

s

B31.316 " Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 65: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" s/40 - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 66: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 67: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" s/80 - 0.844" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.00"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.688" Max Individual Width: 0.125" Max Cumulative Length: 3.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.281" Max Individual Width: 0.094" Max Cumulative Length: 0.844" in 10.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.266" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.422"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.844" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.281"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 68: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" s/120 - 1.219" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.407"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.438" Max Individual Width: 0.125" Max Cumulative Length: 4.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.406" Max Individual Width: 0.094" Max Cumulative Length: 1.219" in 14.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.829" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.610"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.219" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.406"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 69: Asme b31.3 Acceptance Rt Tabulated

s

B31.316" s/160 - 1.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Welds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.782"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.188" Max Individual Width: 0.125" Max Cumulative Length: 6.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.531" Max Individual Width: 0.094" Max Cumulative Length: 1.594" in 19.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.391" in a 19.128" length of weldMax group length of Aligned Internal Porosity: 0.797"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.594" in a 19.128" length of weldMax group length of Aligned Internal Porosity: 0.531"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 70: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" s/10 - 0.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.281"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.436" Max Individual Width: 0.109" Max Cumulative Length: 0.872" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.218" in 2.616" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 71: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 72: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" s/40 - 0.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.750"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.188" Max Individual Width: 0.125" Max Cumulative Length: 2.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.198" Max Individual Width: 0.094" Max Cumulative Length: 0.594" in 7.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.223" Max Size of Isolated Internal Porosity: 0.297"Max Sum of diameters of Aligned Porosity: 0.891" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.149" Max Size of Isolated Internal Porosity: 0.198"Max sum of diameters of Aligned Porosity: 0.594" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 73: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.0" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.0" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 74: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" s/80 - 1.031" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.219"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.062" Max Individual Width: 0.125" Max Cumulative Length: 4.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.344" Max Individual Width: 0.094" Max Cumulative Length: 1.031" in 12.372"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.547" in a 12.372" length of weldMax group length of Aligned Internal Porosity: 0.516"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.031" in a 12.372" length of weldMax group length of Aligned Internal Porosity: 0.344"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 75: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" s/120 - 1.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.688"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.00" Max Individual Width: 0.125" Max Cumulative Length: 6" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.500" Max Individual Width: 0.094" Max Cumulative Length: 1.500" in 18.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.250" in a 18.00" length of weldMax group length of Aligned Internal Porosity: 0.750"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.500" in a 18.00" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 76: Asme b31.3 Acceptance Rt Tabulated

s

B31.320" s/160 - 1.969" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Welds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 2.157"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.938" Max Individual Width: 0.125" Max Cumulative Length: 7.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.656" Max Individual Width: 0.094" Max Cumulative Length: 1.696" in 23.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.954" in a 23.628" length of weldMax group length of Aligned Internal Porosity: 0.985"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.969" in a 23.628" length of weldMax group length of Aligned Internal Porosity: 0.656"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 77: Asme b31.3 Acceptance Rt Tabulated

s

B31.324" s/10 - .250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.00" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.00" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 78: Asme b31.3 Acceptance Rt Tabulated

s

B31.324" s/40 - 0.688" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.844"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.376" Max Individual Width: 0.125" Max Cumulative Length: 2.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.229" Max Individual Width: 0.094 Max Cumulative Length: 0.688" in 8.256"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.344"Max Sum of diameters of Aligned Porosity: 1.032" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.229"Max sum of diameters of Aligned Porosity: 0.688" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 79: Asme b31.3 Acceptance Rt Tabulated

s

B31.324" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094 Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 80: Asme b31.3 Acceptance Rt Tabulated

e

s

B31.324" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforc ` S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094 Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 81: Asme b31.3 Acceptance Rt Tabulated

s

B31.324" s/80 - 1.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.406"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.438" Max Individual Width: 0.125" Max Cumulative Length: 4.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.406" Max Individual Width: 0.094 Max Cumulative Length: 1.219" in 14.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.829" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.610"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.219" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.406"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 82: Asme b31.3 Acceptance Rt Tabulated

s

B31.324" s/160 - 2.344" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6Welds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 2.532"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 4.688" Max Individual Width: 0.125" Max Cumulative Length: 9.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.781" Max Individual Width: 0.094 Max Cumulative Length: 2.344" in 28.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.563"Max Sum of diameters of Aligned Porosity: 3.516" in a 28.128" length of weldMax group length of Aligned Internal Porosity: 1.125"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.375"Max sum of diameters of Aligned Porosity: 2.344" in a 28.128" length of weldMax group length of Aligned Internal Porosity: 0.750"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 83: Asme b31.3 Acceptance Rt Tabulated

s

B31.336" s/10 - 0.312" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.437"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.624" Max Individual Width: 0.125" Max Cumulative Length: 1.248" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.104" Max Individual Width: 0.094" Max Cumulative Length: 0.312" in 3.744"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.117" Max Size of Isolated Internal Porosity: 0.156"Max Sum of diameters of Aligned Porosity: 0.468" in a 3.744" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.936"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.078" Max Size of Isolated Internal Porosity: 0.104"Max sum of diameters of Aligned Porosity: 0.312" in a 3.744" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.624"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 84: Asme b31.3 Acceptance Rt Tabulated

s

B31.336" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 85: Asme b31.3 Acceptance Rt Tabulated

s

B31.336" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 86: Asme b31.3 Acceptance Rt Tabulated

s

B31.336" s/40 - 0.750" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.906"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.500" Max Individual Width: 0.125" Max Cumulative Length: 3.00" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.250" Max Individual Width: 0.094" Max Cumulative Length: 0.750" in 9.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.125" in a 9.00" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.750" in a 9.00" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"