24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com ASCENT™ MULTI-VIEW DIRECT VENT GAS FIREPLACE W415-1897 / 09.25.18 Specifications Framing Model BTU Width Height Depth Viewing Area Actual Min. Framing Max. Framing Actual Framing Actual Min. Framing Max. Framing BHD4P 30,000 43 1/4 42 1/2 43 1/2 38 1/4 46 1/2 25 1/8 22 1/8 24 1/8 28 1/2 x 35 1/2 (Main) 27 1/8 x 17 (End) BHD4ST 30,000 45 45 1/2 45 1/2 38 1/4 46 1/2 25 1/8 22 1/8 24 1/8 45 1/2" [115.6cm] 46 1/2" [118cm] A A: MIN 22 1/8" (56.2cm) MAX 24 1/8" (61.3cm) A B 46 1/2" [118cm] A: MIN 22 1/8" (56.2cm) MAX 24 1/8" (61.3cm) B: MIN 42 1/2" (108cm) MAX 43 1/2" (110.5cm) See-Thru Peninsula Minimum Clearance to Combustible Enclosures Combustible Non-combustible Brick 3" [76mm] 2" [51mm] Firestop 43" [109.2cm] minimum rise** 45" [114.3cm] 6" [152mm] minimum wall 38 1/4" [97.2cm] SAFETY BARRIER 3" [76mm] * 62 1/4" [158cm] minimum to ceiling 11 3/4" [298mm] 50" [127cm] minimum enclosure * Within the appliance enclosure a minimum 3” (76mm) clearance between the top of the vent pipe and combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits the enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 2” (51mm) for vertical. ** See "venting" section. Combustible Non-combustible Brick 3" [76mm] 2" [51mm] Firestop 43" [109.2cm] minimum rise ** 43 1/4" [110cm] 38 1/4" [97.2cm] SAFETY BARRIER 3" [76mm] * 62 1/4" [158cm] minimum to ceiling 11 3/4" [298mm] 50" [127cm] minimum enclosure IMPORTANT: This appliance requires a minimum inside enclosure height of 50" (127cm), measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. See-Thru Peninsula
4
Embed
ASCENT™ MULTI-VIEW DIRECT VENT GAS FIREPLACE...ASCENT MULTI-VIEW DIRECT VENT GAS FIREPLACE W415-1897 / 09.25.18 Specifications Framing Model BTU Width Height Depth Viewing Area Actual
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
* Within the appliance enclosure a minimum 3” (76mm) clearance between the top of the vent pipe and combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits the enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 2” (51mm) for vertical.** See "venting" section.
CombustibleNon-combustible
Brick
3" [76mm]
2" [51mm]
Firestop
43" [109.2cm]minimum
rise**
45" [114.3cm]6" [152mm]
minimum wall
38 1/4"[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4" [158cm]minimumto ceiling
11 3/4"[298mm]
50" [127cm]minimumenclosure
CombustibleNon-combustible
Brick
3" [76mm]
2" [51mm]
Firestop
43" [109.2cm]minimum
rise **
43 1/4" [110cm]
38 1/4"[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4" [158cm]minimumto ceiling
11 3/4"[298mm]
50" [127cm]minimumenclosure
IMPORTANT: This appliance requires a minimum inside enclosure height of 50" (127cm), measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed.
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.
When venting, the horizontal run must be kept to a maximum of 20 feet (6m). If a 20 foot (6m) horizontal run is required, the appliance must have a minimum vertical rise off the appliance of 57" (144.8cm).
On all horizontal vent runs, ensure that the vent pipe does not slope downward.
* See "venting".
43" (109.2cm) MIN PLUS RISE*
24" (61cm)MAX
APPLIANCE
RECESS OR ALCOVE AREA
The recesses or alcoves can be made as deep as desired provided the minimum clearances to combustibles are maintained.The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment can be made by increasing any or all of the height, width and depth of the enclosure.
44.2A
ENCLOSURE AREA
note:Recesses or alcoves above the appliance must be made with non-combustible material and regular minimum clearances, as defined for combustible materials, must still be applied.
The recesses or alcoves can be made as deep as desired provided the minimum clearances to combustibles are maintained.The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment can be made by increasing any or all of the height, width and depth of the enclosure.
Recesses or alcoves above the appliance must be made with non-combustible material and regular minimum clearances, as defined for combustible materials, must still be applied.
* À l’intérieur de l’enceinte, un dégagement de 3” (76mm) est requis entre le haut du conduit d’évacuation et les matériaux combustibles. Pour tout autre dégagement à l’intérieur de l’enceinte, y compris l’endroit où le conduit d’évacuation sort de l’enceinte, l’espacement requis est de 2” (51mm) à partir des côtés et du bas, de 3” (76mm) à partir du haut pour les sections horizontales, et de 2” (51mm) pour les sections verticales. ** Voir la section « évacuation ».
COMBUSTIBLEMATÉRIAUX INCOMBUSTIBLE
BRIQUE
3" [76mm]
2" [51mm]
COUPE-FEU
43" **[109,2cm]
PLUSL'ÉLÉVATION
45" [114,3cm]6" [152mm]
MINIMUM WALL
38 1/4"[97,2cm]
ÉCRAN DE PROTECTION
3" [76mm] *
62 1/4" [158cm]
PLAFONDMINIMALE
11 3/4"[298mm]
HAUTEURMINIMALE DEL'ENCEINTE
50" [127cm]
COMBUSTIBLEMATÉRIAUX INCOMBUSTIBLE
BRIQUE
3" [76mm]
2" [51mm]
COUPE-FEU
43" **[109.2cm],
PLUSL'ÉLÉVATION
43 1/4" [110cm]
38 1/4"[97,2cm]
3" [76mm] *
62 1/4" [158cm]
PLAFONDMINIMALE
11 3/4"[298mm]
HAUTEURMINIMALE DEL'ENCEINTE
50" [127cm] ÉCRAN DE PROTECTION
IMPORTANT: Cet appareil requiert un hauteur d’enceinte minimale de 50" (127cm), à partir de la base de l’appareil. Afin de respecter les contraintes de température, cet espace doit demeurer sans obstruction.
Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour infor-mation d’installation actuel.
W415-1897 / 09.25.18
Dimensions
Installation Typique d’ÉventDégagements Combustible de la Tablette
BHD4ST ILLUSTRÉ
BHD4P ILLUSTRÉ
38 1/4"841mm
34 3/16"868mm
43 1/4" 1099mm
8"203mm 5"
127mm12 13/16"
325mm
25 1/8"638mm
7 9/16"192mm
7 9/16"192mm
2 1/16"53mm
34 3/16"868mm
45" 1143mm
38 1/4"841mm
7 9/16"192mm
7 9/16"192mm
2 1/16"53mm
8"203mm 5"
127mm
25 1/8"638mm
12 13/16"325mm
ENTRÉE DUÉLECTRIQUE
ENTRÉE DUGAZ
ENTRÉE DUÉLECTRIQUE
ENTRÉE DUGAZ
CÔTÉ DROITE
CÔTÉ GAUCHE
CÔTÉ DROITE
CÔTÉ GAUCHEÉCRAN DE PROTECTION
ÉCRAN DE PROTECTION
Installation en alcôve
DIMENSIONS DE LA TABLETTERéf Hauteur ProfondeurD 4" (102mm) 2” (51mm)C 6" (152mm) 4” (102mm) B 8" (203mm) 6” (152mm)A 10" (254mm) 8” (203mm)
La course horizontale doit être conservée à un maximum de 20 pieds (6m). Si une course horizontale de 20 pieds (6m) est requise, l’appareil devra avoir une élévation verticale immédiatement à la sortie de l’appareil d’un minimum de 57 pouces (144,8cm).
Sur toutes les courses horizontales, assurez-vous que la pente des conduits d’évent ne soit pas descendante.
* Voir la section « évacuation ».
43" (109.2cm) min. plus le pente*
24" (61cm)max.
Les évidements ou les alcôves peuvent être faits aussi profondément que souhaité à condition que les dégagements minimaux aux combustibles soient maintenus.Le volume minimal de l'enceinte doit être augmenté d'au moins la valeur du volume de la zone encastrée. Cet ajustement peut être réalisé en augmentant une ou toutes les dimensions de l'enceinte.
44.2A
APPAREIL
ZONE ENCASTRÉE OU ALCÔVE
ZONE ENCEINTE
note:Les zones encastrées ou les alcôves au dessus de l’appareil doivent être fabriqués avec un matériau incombustible et des dégagements minimaux réguliers, tel que défini pour les matériaux combustibles, doivent toujours être appliqués.
Les évidements ou les alcôves peuvent être faits aussi profondément que souhaité à condition que les dégagements minimaux aux combustibles soient maintenus.Le volume minimal de l’enceinte doit être augmenté d’au moins la valeur du volume de la zone encastrée. Cet ajustement peut être réalisé en augmentant une ou toutes les dimensions de l’enceinte.
Les zones encastrées ou les alcôves au dessus de l’appareil doivent être fabriqués avec un matériau incombustible et des dégagements minimaux réguliers, tel que défini pour les matériaux combustibles, doivent toujours être appliqués.