Top Banner
Refrigerant Management System introduces the Energy efficiency from the power of the vortex ArticMaster TM
17

Articmaster Refrigerant Management System

Jun 25, 2015

Download

Business

EnergySavings

Proven in a wide variety of global conditions. Strong client payback – typically 1.5 to 3 years. Synergy with other energy saving products. Achieved the guaranteed efficiency improvements
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Articmaster Refrigerant Management System

Refrigerant Management System

introduces the

Energy efficiency from the power of the vortex

ArticMasterTM

Page 2: Articmaster Refrigerant Management System

Energy Efficiency

Minimum 20% for

air cooled systems

Minimum 8% to 12%

for water cooled

systems

Page 3: Articmaster Refrigerant Management System

Product Description• Suitable for almost all types of air-conditioning, refrigeration and heat pump systems (Centrifugal Chillers are an exception)

• Suitable for all refrigerants, including synthetics

• 10kW to 1000kW plus Systems

• Installed by trained & accredited technicians using detailed Installation Procedures

• A Warranty Form can be supplied with every installation

Page 4: Articmaster Refrigerant Management System

Product Description

Achieves Energy Efficiency with:

• Reciprocal, Screw & Scroll compressors

• DX or Electronic Expansion devices

• Air & water cooled systems

Page 5: Articmaster Refrigerant Management System

Product Attributes 1System works by:

• Lowering head and suction pressure

• Lowering the supply air or water temperature

• Reducing compressor Amp draw

• Allows the System to act as a variable Condenser Control

Page 6: Articmaster Refrigerant Management System

Product Attributes 2• Worldwide Patented Technology

• No moving parts and is virtually maintenance free

• Requires no energy source and reduces carbon emissions

• Significant Carbon Footprint reduction

• Extends compressor and system life

• Reusable within specification

• Minimum forty year life

Page 7: Articmaster Refrigerant Management System

System ComponentsArticmaster Turbulator (Fixed Vane)

Page 8: Articmaster Refrigerant Management System

Articmaster Operation

Compressor

Vortex

Turbulator

Turbulent Flow

Expansion Device10% Boundary Region

LAMINAR FLOW

1% Boundary Region

TURBULENT FLOW

Evaporator Coil

Condenser

Coil

ArticMasterArticMasterTM TM

Mounted 150 mm above top of condenser

Page 9: Articmaster Refrigerant Management System

Articmaster System Map

Laminar Flow

Turbulent Flow

CompressorLower Head and Suction pressure creates lower Evaporator temp

Colder Supply

Air

Articmaster causes creation of “wetter” refrigerant

Vortical flow formed here

Vortical flow “pumps” refrigerant through TX valve eliminating the possibility of flash gas

Page 10: Articmaster Refrigerant Management System

Australasian Installs - 1

• Hotel complex, Darwin• Retail outlet, Sydney• Manufacturing plant, Brisbane• Office block, Melbourne

Page 11: Articmaster Refrigerant Management System

Australasian Installs - 2• Car showroom, Sydney• Target Shopping Centre, Sydney• QLD Government Buildings and Police Stations• Museums• Wineries• and many more.

Page 12: Articmaster Refrigerant Management System

Calculating Efficiencies• Efficiency improvement

calculated from ACTUAL / REAL differences in:-

70º

69º

68º

67º

66º

65º

71º

72º

73º

74º

75º

76º

77º

78º

79º

80º

TYPICAL SETTING

TYPICAL SETTING

COOLING Cost of keeping

room temperatures above and below 78º

HEATING Cost of keeping room temperatures above and below 70º using any type of fuel

15% LESS

8% LESS

8% MORE

16% MORE

24% MORE

32% MORE

40% MORE

48% MORE

6% MORE

11% MORE

17% MORE

23% MORE

29% MORE

6% LESS

11% LESS

17% LESS

22% LESS

26% LESS

Note: Percentages of change are for air condit ioning and heating costs only, not total energy bill.

A COMMITMENT TO SERVICE

TXU ELECTRIC & GAS

Compressor Amps plus

Supply Air/Water Temperature i.e. TXU Thermometer

Plus (when appropriate)

Relative humidity, and/or

Ambient temperature

Page 13: Articmaster Refrigerant Management System

Australasian Case Study

Compr essor Compar ison Char ts

6

7

8

9

10

11

12

O9OOFr i

15OO 21OO O3OO O9OOSat

15OO 21OO O3OO O9OOSun

15OO

Time And Day

Am

ps

20

30

40

50

60

70

80

Tem

per

atu

re

Amps Bef or e

Amps A f ter

Temp Bef or e

Temp A f ter

Before & after

ambient temperatures

Reduced amps

Same ambient

temperature

Compressor amp draw

Page 14: Articmaster Refrigerant Management System

Evapor ator Effi ciency

45

50

55

60

65

70

75

80

O9OOFr i

15OO 21OO O3OO O9OOSat

15OO 21OO O3OO O9OOSun

15OO

Time And Day

De

gr

ee

F

Air On Bef or e

Air Off Bef or e

Air On Af ter

Air Off Af ter

Australasian Case Study

But with 4oF Colder Supply Air Temperature

AFTER Same Return Temperature

Return Air Temperature

Supply Air Temperature

Page 15: Articmaster Refrigerant Management System

34% efficiency improvement

31% efficiency improvement

Australasian Case Study ACTUAL WARRANTY FORMS

Page 16: Articmaster Refrigerant Management System

Articmaster Summary

• Proven in a wide variety of global conditions

• Strong client payback – typically 1.5 to 3 years

• Synergy with other energy saving products

• Achieved the guaranteed efficiency improvements

Page 17: Articmaster Refrigerant Management System

ArticMasterTM Refrigerant Management

System

Energy efficiency from the power of the vortex