Top Banner
87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 Cat. No(s).: 5 750 70/80/90 - 5 751 00/20/30/40/50/60 5 752 00/10 - 5 753 70 5 755 40/50/60 - 5 756 10 Arteor TM White plates for british standard Technical sheet: F00864EN/02 Updated: 01/02/2012 Created: 07/07/2009 1/3 CONTENTS 1. USE Plates for covering mechanisms. 2. RANGE 5 752 00 5 756 10 5 752 10 Designation Cat. No. Number of modules Fixing method Weight (g) 1 module plate square 1 gang 5 752 00 1 with clips 26.4 2 modules plate square 1 gang 5 752 10 2 with clips 22 2 modules plate round 1 gang 5 756 10 2 with clips 27.9 3 modules plate square (horizontal & vertical mounting) 1 gang 5 751 60 3 with clips 23.6 3 modules plate round (horizontal & vertical mounting) 1 gang 5 755 60 3 with clips 24.5 3 modules plate square 2 gang 5 750 70 3 with clips 38.1 3 modules plate round 2 gang (frame included) 5 755 40 3 with clips 65.6 2 x 2 modules plate square 2 gang 5 750 80 2 x 2 with clips 35.2 2 x 2 modules plate round 2 gang 5 755 50 2 x 2 with clips 36.8 6 modules plate square (frame included) 5 753 70 6 with clips 86.4 CONTENTS Page 1. Use ....................... 1 2. Range.................... 1-2 3. Overall dimensions........... 2 4. Mounting .................. 3 5. Technical characteristics ...... 3 6. Cleaning ................... 3 7. Special use................. 3
3

ArteorTM 5 752 1 - 5 753 7 White plates or ritish stanardhabitech.s3.amazonaws.com/PDFs/LEG/F00864EN-02.pdf · White plates for british standard CONTENTS 4. MOUNTING The plates clip

Jul 10, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ArteorTM 5 752 1 - 5 753 7 White plates or ritish stanardhabitech.s3.amazonaws.com/PDFs/LEG/F00864EN-02.pdf · White plates for british standard CONTENTS 4. MOUNTING The plates clip

87045 LIMOGES CedexTelephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88

Cat. No(s).: 5 750 70/80/90 - 5 751 00/20/30/40/50/60 5 752 00/10 - 5 753 70 5 755 40/50/60 - 5 756 10

ArteorTM

White plates for british standard

Technical sheet: F00864EN/02 Updated: 01/02/2012 Created: 07/07/2009

1/3CONTENTS

1. USE

Plates for covering mechanisms.

2. RANGE

5 752 00 5 756 105 752 10

Designation Cat. No. Number of modules Fixing method Weight (g)

1 module plate square1 gang

5 752 00 1 with clips 26.4

2 modules plate square1 gang

5 752 10 2 with clips 22

2 modules plate round1 gang

5 756 10 2 with clips 27.9

3 modules plate square(horizontal & vertical mounting)

1 gang5 751 60 3 with clips 23.6

3 modules plate round(horizontal & vertical mounting)

1 gang5 755 60 3 with clips 24.5

3 modules plate square2 gang

5 750 70 3 with clips 38.1

3 modules plate round2 gang

(frame included)5 755 40 3 with clips 65.6

2 x 2 modules plate square2 gang

5 750 80 2 x 2 with clips 35.2

2 x 2 modules plate round2 gang

5 755 50 2 x 2 with clips 36.8

6 modules plate square(frame included)

5 753 70 6 with clips 86.4

CONTENTS Page

1. Use. . . . . . . . . . . . . . . . . . . . . . . 1 2. Range. . . . . . . . . . . . . . . . . . . . 1-2 3. Overall dimensions. . . . . . . . . . . 2 4. Mounting . . . . . . . . . . . . . . . . . . 3 5. Technical characteristics . . . . . . 3 6. Cleaning . . . . . . . . . . . . . . . . . . . 3 7. Special use. . . . . . . . . . . . . . . . . 3

Page 2: ArteorTM 5 752 1 - 5 753 7 White plates or ritish stanardhabitech.s3.amazonaws.com/PDFs/LEG/F00864EN-02.pdf · White plates for british standard CONTENTS 4. MOUNTING The plates clip

ArteorTM

White plates for british standard

Cat. No(s).: 5 750 70/80/90 - 5 751 00/20/30/40/50/60 5 752 00/10 - 5 753 70 5 755 40/50/60 - 5 756 10

Technical sheet: F00864EN/02 Updated: 01/02/2012 Created: 07/07/2009

2/3CONTENTS

3. OVERALL DIMENSIONS (continued)

2. RANGE (continued)

Designation Cat. No. Number of modules Fixing method Weight (g)

Plate for 13 A fused connecting unit 1 gang

5 751 20 with clips 24

Plate for 13 A twin switchedsocket outlet 2 gang

5 751 00 with clips 42

Plate for 5 A and 13 A switched socket outlet 1 gang

5 750 90 with clips 28

Plate for cocker unit2 gang

5 751 50 with clips 56

Blanking cover plate1 gang

5 751 30 with clips 25

Blanking cover plate2 gang

5 751 40 with clips 41.2

Cat. No. L1 L2 A B

5 750 70157

92

68 45.4

5 750 80 2 x 45.4 2 x 45.4

5 750 90 92

5 751 00 157

5 751 2092

5 751 30

5 751 40157

5 751 50 1 x 45.4 1 x 45.4

5 751 60

92

45.4 68

5 752 00 22.8 45.4

5 752 10 45.4 45.4

5 753 70 237.5 135.8 45.4

5 755 40157

68 45

5 755 50 2 x Ø 45.4

5 755 6092

45 68

5 756 10 Ø 45.4

3. OVERALL DIMENSIONS

L

A

9B

8

Page 3: ArteorTM 5 752 1 - 5 753 7 White plates or ritish stanardhabitech.s3.amazonaws.com/PDFs/LEG/F00864EN-02.pdf · White plates for british standard CONTENTS 4. MOUNTING The plates clip

Cat. No(s).: 5 750 70/80/90 - 5 751 00/20/30/40/50/60 5 752 00/10 - 5 753 70 5 755 40/50/60 - 5 756 10

Technical sheet: F00864EN/02 Updated: 01/02/2012 Created: 07/07/2009

3/3

ArteorTM

White plates for british standard

CONTENTS

4. MOUNTING

The plates clip on in notches onto screw-type or claw-type mounting supports (notches are used for thickness compensation. E.g: wall paper). Easy to remove with a screwdriver.No flatness defect of more than 1.5 mm in a periphery of 10 cm around the installed flush box.Protection film must be removed only once site work is fully completed.

5. TECHNICAL CHARACTERISTICS

5.1 Mechanical characteristicsImpact tests: IK 04

5.2 Material characteristicsFront plate: polycarbonateUnder plate: polycarbonate

5.3 Climatic characteristicsStorage temperatures: - 10° C to + 70° COperating temperatures: - 5° C to + 50° C

6. CLEANING

Surface cleaning with a cloth.Do not use: acetone, tar remover, trichloroethylene.

6.1 Resistance to cleaning agentsHexane (EN 60669-1), methylated spirits, soapy water, glass cleaning substance.

6.2 Resistance to hospital-type cleaning agentsResistance to the following agents: Anios, Surfanios, Bactilysine, Hydrogen peroxyde (30%).

7. SPECIAL USE

Arteor plates must not be painted.