www.armadillonvinc.com Thermal Break Material Armatherm Grade FRR Introduction For Structural Steel Connections Reducing heat flow within a building’s thermal envelope reduces energy consumption as well as potential condensation issues. Thermal bridging through steel and concrete framing can have a significant impact on a buildings’ energy performance. Armatherm™ FRR thermal break material provides low thermal conductivity and high compressive strength. Armatherm™ FRR is made of a reinforced, thermoset resin which is fire resistant, does not readily burn and has very limited creep under load making it the ideal material for use in structural thermal break connections. Maximum Loading Pressure PSI 45,000 Compressive Modulus PSI 1,450,000 Shear Strength PSI 16,000 Standard Thickness 1/2”, 3/4”, 1,” & 2” Thermal Conductivity Btu ft/ft2h°F 0.103 Thermal Conductivity W/m°K 0.20 1 Minimum Operating Temp °F -60 Maximum Operating Temp °F 220 Specifications of Armatherm TM FRR Internal Steel Work External Steel Work Thermal Break Material 1 For comparison, the thermal conductivity of Mild Steel is 56 W/m.K e: [email protected] Call 800 580 3984 For all enquiries Armatherm TM Thermal bridging solutions to improve building envelope performance • Beam Connections • Masonry Shelf Angles • Lintels • Canopies • Balconies • Curtain Wall Mullions • Rain Screens • Z Girts • Roof Penetrations Armadillo NV, 4 Middle Street, Fairhaven, MA 02719
2

Armatherm™ Structural Thermal Bridging Solutions - Thermal ... · 2017-04-26 · Thermal Break Material Armatherm™ Grade FRR Introduction For Structural Steel Connections Reducing

Jul 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Armatherm™ Structural Thermal Bridging Solutions - Thermal ... · 2017-04-26 · Thermal Break Material Armatherm™ Grade FRR Introduction For Structural Steel Connections Reducing

www.armadillonvinc.com

Thermal Break MaterialArmatherm™ Grade FRR

Introduction

For Structural Steel Connections

Reducing heat flow within a building’s thermalenvelope reduces energy consumption as well aspotential condensation issues. Thermal bridgingthrough steel and concrete framing can have asignificant impact on a buildings’ energy performance.Armatherm™ FRR thermal break material provideslow thermal conductivity and high compressivestrength. Armatherm™ FRR is made of a reinforced,thermoset resin which is fire resistant, does not readilyburn and has very limited creep under load making itthe ideal material for use in structural thermal breakconnections.

Maximum Loading Pressure PSI 45,000Compressive Modulus PSI 1,450,000Shear Strength PSI 16,000Standard Thickness 1/2”, 3/4”, 1,” & 2”Thermal Conductivity Btu ft/ft2h°F 0.103Thermal Conductivity W/m°K 0.201

Minimum Operating Temp °F -60Maximum Operating Temp °F 220

Specifications of ArmathermTM FRR

Internal Steel Work

External Steel Work

Thermal Break Material

1For comparison, the thermal conductivity of Mild Steel is 56 W/m.K

e: [email protected] 800 580 3984 For all enquiries

ArmathermTM Thermal bridging solutions to improve building envelope performance

• Beam Connections• Masonry Shelf Angles• Lintels• Canopies• Balconies

• Curtain Wall Mullions• Rain Screens• Z Girts• Roof Penetrations

Armadillo NV, 4 Middle Street,Fairhaven, MA 02719

Page 2: Armatherm™ Structural Thermal Bridging Solutions - Thermal ... · 2017-04-26 · Thermal Break Material Armatherm™ Grade FRR Introduction For Structural Steel Connections Reducing

www.armadillonvinc.com

Armatherm™ Grade FRR

Washer and Bushing

Washer and Bushing

A thermal break should also be provided at the front side of the bolt headbetween the steel washer and face of the exterior steel. This prevents athermal bridge through the bolt which would otherwise provide a path forheat flow through the thermal break assembly. ArmathermTM washersand bushings are recommended to eliminate this path and any potentialfor condensation within the building envelope. Contact us for assistancewith your structural design or thermal calculations.

Bolt Size Hole Bushing ID Bushing Hole in BushingIn Pad OD Structure Length

(Standard)

M12 14 14 20 20 101/2” 0.55” 0.55” 0.78” 0.78” 0.375”M16 18 18 24 24 135/8” 0.70” 0.70” 1.0” 1.0” 0.50”M20 22 22 28 28 133/4” 0.86” 0.86” 1.10” 1.10” 0.50”M24 26 26 32 32 171” 1.05 1.05 1.25” 1.25” 0.625”

Bushing Detail

Bolt Size Washer Washer ThicknessID OD

M12 14 30 61/2” 0.55” 1.18” 0.25”M16 18 40 65/8” 0.7 1.57” 0.25”M20 22 47 63/4” 0.86 1.85” 0.25”M24 26 50 61” 1” 2.00” 0.25”

Washer Detail

Call 800 580 3984 For all enquiriese: [email protected]

Internal Steel Work (Warm Face)

External Steel Work (Cold Face)

Washer

Polyurathane Nut Cap (Optional)

Galvanised or Stainless Steel Nut

Galvanised or Stainless Steel Bolt

Armatherm™ Thermal Washer

Armatherm™ Thermal Bushing

Armatherm™ Thermal Break Plate