Arkansas State Data Center West ► Automatic fire protection system on first floor ► 300 tons of cooling to IT equipment in data center (Enough to serve 75 average residential homes) ► Modern 9,600 square foot, physically secure data center 20,000 gallons combined fuel capacity 6 times greater total generator capacity than MAC data center (Enough to power 6,000+ average Arkansas households) ► 3 diesel powered generators (total 4.95MW) for emergency power ► Integrated electrical system surge protection ► IT equipment dual powered by multiple supplies fed from different distribution paths ► On-site fuel storage exceeds 7-days run time ► Secured office space for monitoring/managing the data center ► Battery/generator back-up and conditioned power for data center and second floor command center ► Concurrently maintainable power and cooling infrastructure ► Redundant capacity components enable safe maintenance About SDC West Arkansas State Data Center West
2
Embed
Arkansas State Data Center West Secured office space for monitoring/managing the data center Battery/generator back-up and conditioned power for data center and second floor command
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Arkansas State Data Center West
► Automatic fire protection system on first floor
► 300 tons of cooling to IT equipment in data center (Enough to serve 75 average residential homes)
► Modern 9,600 square foot, physically secure data center
20,000 gallons combined fuel capacity6 times greater total generator capacity than MAC data center (Enough to power 6,000+ average Arkansas households)
► 3 diesel powered generators (total 4.95MW) for emergency power
► Integrated electrical system surge protection
► IT equipment dual powered by multiple supplies fed from different distribution paths
► On-site fuel storage exceeds 7-days run time
► Secured office space for monitoring/managing the data center
► Battery/generator back-up and conditioned power for data center and second floor command center
► Concurrently maintainable power and cooling infrastructure
Periodic failover & disaster recovery testing to be performed in Little Rock. No out of state travel necessary
Co-location services to lease space for IT systems is availble at SDC West
SDC West is available for multiple levels of disaster backup/recovery services to new and existing customers
Multiple Levels of Backup/Recovery
1. Hot SiteKeep servers and a live backup site operational in the event of a disaster. Enables replication of your production environment at SDC West. Allows immediate cutover in case of a disaster at the primary site.
2. Warm SitePre-install hardware, pre-configure bandwidth needs. If the event of a disaster, load software and data to conduct system restoration.
3. Cold SiteData center space, power, and network connectivity ready to go if/when the need arises. In the event of a disaster, on site personnel will assist with moving hardware into SDC West and assist with system restoration.
Cloud services are available at SDC West. We operate the equipment and you pay for what you use.