Mount St. Francis/Center for Spirituality/ #201846.02 Mount St. Francis G-101 LIFE SAFETY PLAN CODE INFORMATION A-001 ARCHITECTURAL DEMOLITION PLAN A-101 ARCHITECTURAL PLAN DOOR AND FRAME SCHEDULE DOOR DETAILS A-201 DIMENSION PLAN RESTROOM ACCESSORIES PLAN A-401 REFLECTED CEILING PLAN A-901 MISCELLANEOUS DETAILS ARCHITECTURAL DRAWINGS DRAWING SHEET INDEX I-101 FINISH PLAN & CASEWORK ELEVATIONS I-301 INTERIOR ELEVATIONS I-302 INTERIOR ELEVATIONS INTERIORS DRAWINGS PLUMBING DRAWINGS MECHANICAL DRAWINGS ELECTRICAL DRAWINGS 101 St. Anthony Drive Mt. St. Francis, Indiana 47146 2020 Retreat Center 3rd Floor Bathroom Renovations Center for Spirituality 2020 Retreat Center 3rd Floor Bathroom Renovations P-101 PLUMBING DEMOLITION PLUMBING PLAN DWV PLAN & FIXTURE SCHEDULE P-201 PLUMBING DOMESTIC WATER PLAN & ISOMETRICS E-101 LIGHTING PLAN & POWER PLAN M-101 MECHANICAL DEMOLITION MECHANICAL PLAN
14
Embed
ARCHITECTURAL DRAWINGS Mount St. Francis Center for ......Feb 24, 2020 · a-001 architectural demolition plan a-101architectural plan door and frame schedule door details a-201dimension
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Mount
St. Fra
nci
s/C
ente
r fo
r Sp
iritual
ity/
#201846.0
2
Mount St. Francis
G-101 LIFE SAFETY PLANCODE INFORMATION
A-001 ARCHITECTURAL DEMOLITION PLAN
A-101 ARCHITECTURAL PLANDOOR AND FRAME SCHEDULEDOOR DETAILS
FOR BULKHEADS AND SOFFITS: TO BOTTOM OF FINISHED SURFACE.
FOR OPENINGS THROUGH WALLS: TO BOTTOM OF FINISHED OPENING.
Plan Legend:X'-X"
5.
4.
Gypsum Board Ceiling / Soffit
Reflected Ceiling Keynotes
RC1
REFER TO MECHANICAL, ELECTRICAL AND EQUIPMENTDRAWINGS FOR CLARIFICATION OF SYMBOLS USED ONTHE REFLECTED CEILING PLAN TO ILLUSTRATE LAYOUT OFITEMS WITHIN CEILING SYSTEM.
ALL CEILING HEIGHTS ARE TO BE AS NOTED.COORDINATE THIS FINISHED CEILING HEIGHT WITH ALLOTHER TRADES, AND WITH ALL MECHANICAL, ELECTRICALAND OTHER EQUIPMENT AND ITEMS ABOVE CEILING.
UNLESS SPECIFICALLY DIRECTED OTHERWISE, LOCATE ALLGRILLES, REGISTERS, DIFFUSERS, FIXTURES, OR OTHER SUCHEQUIPMENT FLUSH WITH CEILING SURFACE ANDCENTERED ON TILE.
SEE FINISH PLAN FOR TYPE AND STYLE OF CEILING SYSTEMS.
MECHANICAL EQUIPMENT AND LARGE DUCTWORK RUNSMAY BE SHOWN GENERICALLY IN AREAS OF EXPOSEDSTRUCTURE AND ARE INTENDED FOR PURPOSES OFCOORDINATION ONLY. NO PIPING, CONDUIT OR SMALLERITEMS ARE INDICATED IN THESE AREAS. SEE MECHANICAL,PLUMBING, AND ELECTRICAL DRAWINGS FOR FURTHERINFORMATION AND REQUIREMENTS.
COORDINATE NEW CEILING GRID AND PANELINSTALLATION AS REQUIRED WITH EXISTING ITEMSRECESSED IN OR SURFACE MOUNTED TO EXISTINGCEILING. WHERE EXISTING ITEMS TO REMAIN IN PLACE(U.O.N) PROVIDE TEMPORARY SUPPORTS AS REQUIRED &REINSTALL SURFACE MOUNTED ITEMS ON NEW CEILINGPANELS. NOTE: NOT ALL EXISTING ITEMS ARE SHOWN.
Reflected Ceiling Notes
3.
2.
1.
Plaster Veneer Ceiling
WRAP EXPOSED SIDES OF GLAZED CMU TILE WITH
GYPSUM BOARD. SEE DETAIL 3/A-401.
RC2
MATCH EXISTING CEILING HEIGHT.
6.
RC3
AREA OF EXISTING ACOUSTICAL LAY-IN CEILING SYSTEM
TO REMAIN. PROVIDE NEW SUSPENSION SYSTEM AND
EDGE MOLDING AS REQUIRED.
BOT. OF SOFFIT
SEE PLAN
CORNER BEAD
AT ALL CORNERS
(TYPICAL)
3-5/8" x 20 GA. MTL.
STUDS @ 16" O.C.; EXTEND
TO STRUCTURE
LINE OF WALL
LAY-IN CEILING
SYSTEM
3-5/8" x 20 GA. MTL STUD
BRACES @ 48" O.C.
5/8" GYP. BRD.;
EXTEND TO 2" MIN.
ABOVE CLNG.
full size plot scale: 3/4"=1'-0"A-401
1 Gyp. Bd. Bulkhead
8'-0" A.F.F.
SEE PLAN
LINE OF WALL BEYOND
TILE
SCHLUTER TRIM
5/8" GYP. BRD.
CORNER BEAD TYP.
ALL CORNERS
20 GA. 3-5/8" MTL. STUDS @
16" O.C.; EXTEND TO
STRUCTURE
5/8" GYP. BRD.
SEE PLAN
20 GA. 3-5/8" MTL STUD
BRACING @ 48" O.C.
2"
SEE PLAN
ACOUSTIC
PANEL CLG.
full size plot scale: 3/4"=1'-0"
A-401
2 Gyp. Bd. Soffit
5/8" GYP. BOARD
TILE
SCHLUTER TRIM
SCHLUTER TRIM
5/8" GYP. BOARD
THIN VENEER PLASTER OVER
MOISTURE RESISTANT GYP.
BOARD
SEE PLAN
SUSPENDED GYP. BRD.
CEILING TRACK
SEE PLAN
SEE PLAN
full size plot scale: 3/4"=1'-0"A-401
3 Gyp. Bd. Bulkhead
CORNER BEAD TYP.
ALL CORNERS
EXISTING MASONRY
LOAD BEARING WALL
1-1/2" FURRING
CHANNELS
5/8" GYP. BOARD
TILE
ACOUSTIC PANEL
CLG.
SCHLUTER TRIM
5/8" GYP. BOARD
SEE PLAN
SEE PLAN
1-1/2" FURRING
CHANNELS
5/8" GYP. BOARD
TILE
SCHLUTER TRIM
5" x 3-1/2" x 3/8" STEEL
ANGLE SUPPORTS
Sheet
Certified By
Revisions
Project N
o.
Checked By
Draw
n
Date
The Architect/Engineer does not define the scope of
individual trades, subcontractors, material suppliers, or
vendors. Any sheet numbering system used which identifies
disciplines is solely for the Architect/Engineer's
convenience, and is not intended to define a
subcontractor's scope of work. Information regarding
individual trades, subcontractors, material suppliers, and
vendors may be detailed, described and indicated at
different locations throughout these documents. No
consideration will be given to requests for change orders
for failure to obtain and review the complete set of
drawings and specifications when preparing bids, prices,
and quotations.
Notice
630 W
alnut Street
Jeffersonville, IN
47130
812. 282. 9554
812. 282. 9171 FAX
ww
w.koverthaw
kins.com
KovertHawkins Architects
ALL RIGHTS RESERVED
c
A-401
1846.02
02/24/2020
SK
HK
1 2 3 4 5 6
full size plot scale:
North
0
3rd Floor BathroomReflected Ceiling Plan
2'1/4"=1'-0" 4'
Mt. S
t. F
ranci
s, India
na
47146
Cente
r fo
r Sp
iritual
ity
Mount
Sain
t Fra
nci
s
101 S
t. A
nth
ony
Dri
ve
2020 R
etr
eat
Cente
r 3rd
Flo
or
Bat
hro
om
Renova
tions
SCALE: 1/4"=1'-0"
Mounting Heights - Typical
AD
A W
AT
ER
CLO
SET
TO
ILET
PA
PER
DIS
PEN
SER
GR
AB
BA
RS
REST
RO
OM
ST
ALL
MIR
RO
R, C
EN
TER
ED
ON
LA
VA
TO
RY
AD
A L
AV
AT
OR
Y
CO
NT
RO
LS
FO
R A
LL IT
EM
S T
O B
E L
OC
AT
ED
WIT
HIN
TH
IS
AR
EA
UN
LESS
NO
TED
OT
HER
WIS
E
AD
A W
AT
ER
CLO
SET
GR
AB
BA
RS
REST
RO
OM
ST
ALL
5'-0" MIN. CLEAR
8"
5'-0" MIN. CLEAR
1'-6"3'-6"
2'-0"
3'-0"
1'-0"3'-6"
3'-0"
6"
17"-19"
4'-9"
1'-0"
TO
ILET
PA
RT
ITIO
N
AD
A C
OA
T H
OO
K/R
OD
4'-0"
CO
AT
HO
OK
/RO
D5'-6"
TY
PIC
AL H
EIG
HT
PR
OV
IDE (
1)
AT
EA
CH
LO
CA
TIO
N
2'-10"
1'-3"
MIN
.
3'-8" M
AX.
3'-4"
AD
A T
RA
P W
RA
PH
W, C
W, A
ND
DR
AIN
LIN
ES
NOTE:INSTALLATIONS SHALL COMPLY WITH ALL CURRENTGOVERNING CODES AND ADA REQUIREMENTS FORMOUNTING HEIGHTS
AD
A S
HO
WER
SHO
WER
TY
PIC
AL H
EIG
HT
3'-6"
CO
NTRO
LS
6'-4" H
EAD
DU
AL F
IXED
HEA
DS
W/O
HA
ND
SPR
AY
4'-0" AD
A H
EAD
PR
OV
IDE D
IVER
TER
VA
LV
E
AD
A S
HO
WER
3'-6"
CO
NTRO
LS
6'-4" H
EAD
FIX
ED
HEA
D W
ITH
HA
ND
SPR
AY
3'-0"
3'-6"
CO
NTRO
LS
6'-4" H
EAD
3'-0"
PA
PER
TO
WEL D
ISPEN
SER
3'-4"
3'-0"
5'-0"
MO
P H
AN
GER
SAN
ITA
RY
NA
PK
IN D
ISPO
SAL
TO
ILET
PA
PER
DIS
PEN
SER
SAN
ITA
RY
NA
PK
IN D
ISPO
SAL
1'-6"
3'-3"
3'-3"
full size plot scale:
Typical Interior Signage Elevations3"=1'-0"
BRAILLE
WOMEN
ROOM NAME IDENTIFICATION SIGN6-1/2"x 9"
BRAILLE
MEN
ROOM NAME IDENTIFICATION SIGN6-1/2"x 9"
BRAILLE
ROOM IDENTIFICATION SIGN8-1/2"+/-W X 4"H
JANITOR
TYPE "A" TYPE "B" QTY: 2 TYPE "C" QTY: 2ROOM: JANITOR 356
BRAILLE
ROOM IDENTIFICATION SIGN8-1/2"+/-W X 4"H
RESTROOM
TYPE "D"ROOMS: WOMEN 354-A, WOMEN3454-B, MEN 355-A, & MEN 355-B
ROOM: WOMEN 354 ROOM: MEN 355
BRAILLE
RESTROOM
ROOM NAME IDENTIFICATION SIGN6-1/2"x 9"
TYPE "E"ROOMS: WOMEN 354-C & MEN 355-C
5'-0"
TO
CEN
TERLIN
E O
F SIG
NSIGN
2"
full size plot scale:
Interior Signage Mounting
SIGN ON LATCHSIDE OF DOOR
1/2"=1'-0"
FIN. FLOOR
SCHEDULED CEILING(SEE REFLECTED CEILINGS)
EXISTING CONCRETE BLOCK
SCHED. BASE(SEE FINISH PLANS)
Partition Wall full size plot scale: 1/2"=1'-0"
A
58" TILE BACKER BOARD;EXTEND TO 6" MIN. ABOVECEILING
20 GAUGE 1-1/2" HAT CHANNELS @16" O.C. UNLESS OTHERWISE NOTEDEXTEND TO 6" MIN. ABOVE CEILING
full size plot scale:
Partition WallB
1/2"=1'-0"
CONT. STUD RUNNER
SCHEDULED CEILING(SEE REFLECTED CEILINGS)
FIN. FLOOR
5/8" GYP. BD.;EXTEND TO 6" MIN. ABOVECEILING (ONE SIDE)
18 GAUGE MTL. STUDS @16" O.C.(SEE PLANS FOR SIZE);EXTEND TO BOTTOM OF DECK
SCHED. BASE(SEE FINISH PLANS)
full size plot scale:
Partition Wall
18 GAUGE MTL. STUDS @16" O.C.(SEE PLANS FOR SIZE);EXTEND TO BOTTOM OF JOIST (PERP. TO JOIST);EXTEND TO BOTTOM OF DECK (PAR. TO JOIST)
CONT. STUD RUNNER
SCHEDULED CEILING(SEE REFLECTED CEILINGS)
SCHED. BASE(SEE FINISH PLANS)
FIN. FLOOR
5/8" GYP. BD.;EXTEND TO 6" MIN. ABOVE CEILING(BOTH SIDES)
"KOHLER" K-13463 TOUCHLESS FAUCET, CHROME TRIM, AND METAL GRID STRAINER; A/C POWERED
Plumbing Legend
COLD WATER
COLD WATER
VALVE (SHUT-OFF)
HOT WATER (105°)
HOT WATER
CW
105 HW
VENT THRU ROOFVTR
TRAP
VENT
DRAIN
HOT WATER RETURNHWR
Sanitary Plumbing Plan Keynotes
S1EXISTING VERTICAL SANITARY MAIN FOR ALL NEW PIPING TO CONNECT
S2VERTICAL SANITARY DRAIN FOR L-2 FIXTURES ABOVE
S3SANITARY CLEAN OUT IN 3RD FLOOR
S4CAP ALL SANITARY LINES IN CHASE BELOW 3RD FLOOR LEVEL TO SEAL OFF SEWER GAS
S5
REPLACE EXISTING LAVATORY AND MOUNT AT HANDICAP ACCESSIBLE HEIGHT.
MODIFY DRAIN AND SERVICE LINES AS REQUIRED FOR NEW MOUNTING HEIGHT
S6
MODIFY DWV DRAIN LINES TO NEW WALL LOCATION. REINSTALL EXISTING SINK AND
MAKE ALL REQUIRED RECONNECTIONS.
DN
UP
Women
Men
Corridor
Plumbing Demolition Notes
D1REMOVE TOILETS, FLUSH VALVES AND ASSOCIATED PIPING.
D2REMOVE WALL HUNG SINKS AND ASSOCIATED PIPING.
D3REMOVE SHOWERS AND ASSOCIATED PIPING.
D4REMOVE MOP SINK AND ASSOCIATED PIPING.
D5REMOVE PIPING FROM CHASE.
D5REMOVE URINALS AND ASSOCIATED PIPING BEHIND ENCLOSURE.
Sheet
Certified By
Revisions
Project N
o.
Checked By
Draw
n
Date
The Architect/Engineer does not define the scope of
individual trades, subcontractors, material suppliers, or
vendors. Any sheet numbering system used which identifies
disciplines is solely for the Architect/Engineer's
convenience, and is not intended to define a
subcontractor's scope of work. Information regarding
individual trades, subcontractors, material suppliers, and
vendors may be detailed, described and indicated at
different locations throughout these documents. No
consideration will be given to requests for change orders
for failure to obtain and review the complete set of
drawings and specifications when preparing bids, prices,
and quotations.
Notice
630 W
alnut Street
Jeffersonville, IN
47130
812. 282. 9554
812. 282. 9171 FAX
ww
w.koverthaw
kins.com
KovertHawkins Architects
ALL RIGHTS RESERVED
c
P-101
1846.02
02/24/2020
SK/H
K
HK
1 2 3 4 5 6
full size plot scale:
North
0
3rd FloorBathroom Plumbing
2'1/4"=1'-0" 4'
Mt. S
t. F
ranci
s, India
na
47146
Cente
r fo
r Sp
iritual
ity
Mount
Sain
t Fra
nci
s
101 S
t. A
nth
ony
Dri
ve
2020 R
etr
eat
Cente
r 3rd
Flo
or
Bat
hro
om
Renova
tions
WC-1WC-1
L-1L-1
SH-1 SH-1
WC-2
SH-2
SH-2
WC-2
WC-2
WC-2
WC-2
WC-2
SH-2
SH-2
MS
L-2L-2
L-2L-2
L-2L-2
L-2L-2
L-1
full size plot scale:
North
0
3rd Floor DWV PipingAbove 2nd Floor Ceiling
2'1/4"=1'-0" 4'
CO CO
CO
CO
CO
FD FD
FD
FD
FD
FD
WC-1
WC-1
L-1L-1
SH-1 SH-1
WC-2
SH-2
SH-2
WC-2
WC-2
WC-2
WC-2
WC-2
SH-2
SH-2
MS
L-2L-2
L-2L-2
L-2L-2
L-2L-2
CO
CO
CO
CO
FD FD
FD
FD
FD
FD
S1
S2
S3
S3
S3
S3
CO
S3
S4
S4
REMOVE ALL SANITARY LINES CURRENTLY SERVING 3RD
FLOOR FIXTURES, BOTH ACTIVE AND ABANDONED. CAP
AS NEEDED TO PREVENT SEWER GAS FROM LOWER FLOORS
S5
full size plot scale:
North
0
3rd Floor BathroomPlumbing Demolition
2'1/4"=1'-0" 4'
D1
D1
D6
D5 D5
D3
D4
D2 D2
D3
D2D2
S6
DN
UP
Women
354
Women
354-A
Women
354-B
Women
354-C
Men
355
Men
355-A
Men
355-B
Men
355-C
Janitor
356
Stair
C
Corridor
353
Bedroom
351
Bedroom
352
General Plumbing Notes
5.
6.
8.
3.
4.
2. WORK INCLUDES FURNISHING ALL LABOR, MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION,SUPERINTENDENCE, CLEAN-UP, AND SERVICES REQUIRED TO CONSTRUCT AND INSTALL A COMPLETE AND FULLY
OPERATIVE PLUMBING SYSTEM FOR THE PROJECT.
INSTALL ALL PLUMBING WORK IN ACCORDANCE WITH ALL STATE AND LOCAL CODES, ALL ADA AND
ACCESSIBILITY LAWS AND REGULATIONS, AND ALL AUTHORITIES HAVING JURISDICTION.
CONTRACTOR SHALL INCLUDE IN HIS BID THE COST OF ALL FEES, PERMITS, TAP-INS, APPROVALS, AND INSPECTIONS.
FURNISH ALL CERTIFICATES OF APPROVALS BY THE PLUMBING INSPECTOR AND BOARD OF HEALTH.
UNLESS OTHERWISE SPECIFIED, ALL FAUCETS, SUPPLIES AND STOPS, TRAPS, WASTES, STRAINERS, AND ESCUTCHEONS,
SHALL BE CHROME PLATED BRONZE. (BRIGHT CHROME FINISH).
TEST ALL PIPING AS REQUIRED BY STATE AND LOCAL PLUMBING CODES.
11. PROVIDE WATER HAMMER ARRESTORS AT ALL LAVATORIES AND SINKS. INSTALL COMPLETE WITH ACCESSIBLEISOLATION VALVE ON HOT AND COLD WATER SUPPLY PIPING. INSTALL PER MANUFACTURER.
7. DISINFECTION AND STERILIZATION OF THE SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH ALL RULES ANDREGULATIONS OF THE STATE BOARD OF HEALTH.
10. PROVIDE NEW SANITARY SEWER SERVICES AND CONNECTIONS AS REQUIRED. VERIFY PIPING ROUTING AND RUNS,
TAP LOCATIONS, AND INVERT ELEVATIONS REQUIRED PRIOR TO COMMENCING WORK. ESTABLISH INVERTELEVATIONS REQUIRED FOR DRAINAGE OF 1/8 INCH PER FOOT SLOPE.ENSURE FOR PROPER CONNECTIONS, INSTALLATION, AND SLOPE FOR DRAINAGE.
9. INSTALL UNIONS DOWNSTREAM OF VALVES AND AT ALL FIXTURES, EQUIPMENT, AND APPARATUS LOCATIONS FORALL PIPING FEEDS.
1. PLUMBING DRAWINGS ARE DIAGRAMMATIC IN NATURE AND REPRESENT CONCEPTUAL ROUTING ONLY.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL CONDITIONS.
12. NO PVC ALLOWED WITHIN OPEN PLENUM SPACE UNLESS THAT PORTION OF PIPING IS IS COVERED WITH 3M FIREBARRIER PLENUM WRAP.
13. FIELD VERIFY ALL CONDITIONS TO COORDINATE ALL WORK AS SHOWN AND/OR INTENDED.
FIELD VERIFY ALL INVERTS REQUIRED.
14. FINISH PAINT ANY/ALL EXPOSED PIPING ON THE INTERIOR OF THE BUILDING TO MATCH ADJACENT SURFACES,WHETHER INDICATED OR NOT. VERIFY COLOR WITH ARCHITECT.
15. IF PVC WATER LINES ARE UTILIZED, THEY SHALL BEAR THE NSF SEAL OF APPROVAL AND MEET COMMERCIALSTANDARDS NO. 256-63, PRODUCT STANDARD 22-70, OR ASTM D-2241.
17.
18.
ALL HOT WATER SUPPLY LINES SERVING ALL HAND WASHING FAUCETS SHALL BE ROUTED THROUGH AN APPROVED
ANTI-SCALD DEVICE SET TO MAXIMUM TEMPERATURE SETTING OF 105 DEGREES FAHRENHEIT. SUBMIT ANTI-SCALDDEVICE AND VERIFICATION OF HEALTH DEPARTMENT APPROVAL TO ARCHITECT PRIOR TO INSTALLATION.
EXISTING SANITARY AND VENT PIPING NOT PART OF NEW WORK SHALL BE CUT AND CAPPED. CUT AND CAPPEDPIPING SHALL BE BELOW FLOORS, WITHIN, WALLS, OR ABOVE CEILINGS. REMOVE PIPING NO LONGER IN USE. NOT ALL
LOCATIONS ARE SHOWN. CONTRACTOR TO FIELD VERIFY. SEE DEMOLITION DRAWINGS.
EXISTING DOMESTIC WATER PIPING NOT PART OF NEW WORK SHALL BE CUT AND CAPPED. CUT AND CAPPED PIPING
SHALL BE BELOW FLOORS, WITHIN, WALLS, OR ABOVE CEILINGS. REMOVE PIPING NO LONGER IN USE. NOT ALLLOCATIONS ARE SHOWN. CONTRACTOR TO FIELD VERIFY. SEE DEMOLITION DRAWINGS.
16.
Plumbing Plan KeynotesTAP EXISTING COLD WATER LINE AT 2ND FLOOR CEILING. EXTEND TO ABOVE 3RDFLOOR CEILING. INSTALL SHUT-OFF ABOVE 2ND FLOOR CEILING FOR THE SERVICE FEEDTO THE 3RD FLOOR TO ISOLATE ALL 3RD FLOOR COLD WATER SERVICE. PROVIDE DRAINABOVE SHUT-OFF TO ALLOW FULL DRAIN DOWN OF 3RD FLOOR LINES.
P1
P2TAP EXISTING HOT WATER LINE AT 2ND FLOOR CEILING. EXTEND TO ABOVE 3RD FLOORCEILING. INSTALL SHUT-OFF ABOVE 2ND FLOOR CEILING FOR THE SERVICE FEED TOTHE 3RD FLOOR TO ISOLATE ALL 3RD FLOOR HOT WATER SERVICE. PROVIDE DRAINABOVE SHUT-OFF TO ALLOW FULL DRAIN DOWN OF 3RD FLOOR LINES.
P3 REPLACE EXISTING LAVATORY AND RAISE TO HANDICAP ACCESSIBLE HEIGHT. MODIFYHOT AND COLD WATER SERVICE LINES TO NEW MOUNTING HEIGHT
P4 MODIFY DWV LINES AND HOT AND COLD WATER SERVICE LINES TO NEW WALLLOCATION. REINSTALL EXISTING SINK, FITTINGS AND ALL CONNECTIONS.
CO
CO
CO
CO
COFD
FD
L-1
L-1
SH-1
SH-2
SH-2
FD
SH-2
SH-1
WC-2
WC-2
FD
L-2
L-2
L-2
L-2
L-2
L-2
L-2
L-2
WC-1
WC-2
FDWC-2
MS
WC-2 SH-2
FD
WC-2
WC-1
4"
3"
3"
4"
4"
4"
4"
4"
4"
1-1/4"
1-1/
4"
2"
2"1-1/
4"
1-1/
4"
3"
3"
3"
3"
3"
3"
3"
3"
3"
2"
1-1/
2"
1-1/
2"
2"
4"
2"
2"
2"
2"
2"
1-1/2"
1-1/2"
2"
3"
1-1/
2"3"
3"
2"
2"
2"
1-1/2"
1-1/
2"
1-1/
2"
1-1/
2"
3"
3"
2"
2"
1-1/2"
1-1/2"
CONNECT TO EXISTING SANITARYPIPING. FIELD VERIFY.
EXISTING VENT THRU ROOF
EXIS
T 4"
VEN
T
3"3"
1-1/
2"2"
2"1-1/
2"
3"
3"
3"
1-1/
2"
1-1/
2"
1-1/2"2"
WC-1
WC-1
L-1
L-1
SH-1
SH-1
L-2
L-2
L-2
L-2
L-2
L-2
L-2
L-2
WC-2
WC-2
WC-2
WC-2
WC-2
WC-2
SH-2
SH-2
SH-2 MS
SH-2
1" HW
1" HW
1" HW
1" HW
1" HW
1-1/2" CW
1-1/2" CW
1-1/2" CW
1-1/2" CW
1-1/2" CW
1" HW
DRAINDRAIN
ISOLATION VALVEISOLATION VALVE
Sheet
Cert
ifie
d By
Revi
sion
s
Proj
ect
No.
Chec
ked
By
Dra
wn
Dat
e
The Architect/Engineer does not define the scope ofindividual trades, subcontractors, material suppliers, orvendors. Any sheet numbering system used which identifiesdisciplines is solely for the Architect/Engineer'sconvenience, and is not intended to define asubcontractor's scope of work. Information regardingindividual trades, subcontractors, material suppliers, andvendors may be detailed, described and indicated atdifferent locations throughout these documents. Noconsideration will be given to requests for change ordersfor failure to obtain and review the complete set ofdrawings and specifications when preparing bids, prices,and quotations.
Notice
630
Wal
nut
Stre
etJe
ffer
sonv
ille,
IN 4
7130
812.
282
. 95
5481
2. 2
82.
9171
FAX
ww
w.k
over
thaw
kins
.com
KovertHawkins ArchitectsALL RIGHTS RESERVED
c
P-201
1846
.02
02/2
4/20
20
AC/H
K
HK
1 2 3 4 5 6
full size plot scale:
North
0
3rd Floor BathroomDomestic Water Piping
2'1/4"=1'-0" 4'
Mt. S
t. F
ranci
s, India
na
47146
Cente
r fo
r Sp
iritual
ity
Mount
Sain
t Fra
nci
s
101 S
t. A
nth
ony
Dri
ve
2020 R
etr
eat
Cente
r 3rd
Flo
or
Bat
hro
om
Renova
tions
WC-1 WC-1
L-1 L-1
SH-1 SH-1
WC-2SH-2
SH-2
WC-2
WC-2
WC-2 WC-2
WC-2
SH-2
SH-2
MS
L-2L-2
L-2L-2
L-2L-2
L-2L-2
CO
FD FD
FD
FD
FD
FD
1-1/2" CW
1-1/
2" C
W
1-1/
2" C
W
1-1/2" CW
1" HW 1" HW
1" HW
1" H
W
1" H
W
1-1/2" CW
1" H
W
P2P1
P3
full size plot scale: NO SCALEP-201
1 DWV Riser Diagram
full size plot scale: NO SCALEP-201
2 Domestic Water Riser Diagram
P1
P2
L-1P4
AutoCAD SHX Text
All information in this document is the confidential and proprietary information of KovertHawkins Architects and shall not be copied, reproduced, distributed, sold, electronically transmitted, assigned to a third party or otherwise appropriated without the prior written consent of KovertHawkins Architects. Unauthorized use is prohibited.
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
T
AutoCAD SHX Text
I
AutoCAD SHX Text
H
AutoCAD SHX Text
C
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
O
AutoCAD SHX Text
K
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
V
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AR00033675
DN
UP
Women
354
Women
354-A
Women
354-B
Women
354-C
Men
355
Men
355-A
Men
355-B
Men
355-C
Janitor
356
Stair
C
Corridor
353
BedroomBedroom
6"100 S
110 E
6"
100 S
110 E
60 S
80 E
80 E
60 S
80 E
80 E
60 S
60 S
60 S170 S
170 S
170 S
170 S
170 S
170 S
16 x 16 S UP TO RTU-1
11 x 23 R UP TO RTU-1
10 x
12
16 x 12
8 x
12
8 x
10
8"255 R 255 R
255 R 255 R
8 x
10
8"
7"7"
7" 7"
7"
7"
5"
5"
5"
5"
5 x
55
x 8
6"
5 x
12
EF-1EF-2
6"
5 x
125
x 8
5 x
5
T
TSTS
Packaged Heat Pump Roof Top Unit Schedule
RTU-1
UNIT MANUF.
LENNOX
MODEL COOLING
-PROVIDE MINIMUM 12" OF CURB ABOVE FINISHED ROOF. CURB BASE FABRICATED FOR ROOF SLOPENOTE:
-AFTER START UP, REPLACE FILTERS EVERY 2 WEEKS UNTIL OWNER OCCUPANCY
VOLTAGE
240-1-60
-PROVIDE LOW AMBIENT COOLING DOWN TO 0° F.- PROVIDE LOUVERED HAIL GUARDS.
- PROVIDE ENTHALPY CONTROLLED ECONOMIZER WITH MOTORIZED DAMPER BAROMETRIC RELIEF DAMPERS
- PROVIDE HINGED ACCESS PANELS AND CONVENIENCE OUTLET POWERED BY THE UNIT VIA TRANSFORMER.- PROVIDE NON-FUSED DISCONNECT AND THRU THE BASE ELECTRICAL CONNECTION
30,000 BTUH
ELECTRICHEATER
1
COMPRESSORS STAGES CFM TOTAL STATIC
0.90 (in. WC)1/4
HP
- PROVIDE OUTDOOR AIR HOODS FOR INTAKE AND RELIEF
- BAROMETRIC RELIEF DAMPERS
- MERV 14 FILTER
10'-0
" M
IN
10'-0" MINIMUM
Exhaust Fan ScheduleUNIT MANUF. MODEL SONESCFM TYPE
- PROVIDE BACKDRAFT DAMPER- PROVIDE WALL CAP WITH BIRDSCREEN
NOTE:
IN-LINEEF-1 COOK SQN-D 3.3270
VOLTAGE
120/1/60
- CONTROL BY MOTION SENSORS IN BATHROOMS (SEE E-101)
IN-LINEEF-2 COOK SQN-D 3.3270 120/1/60
14.
15.
13.
12.
ALL DUCTWORK SEAMS TO BE CHEMICALLY SEALED. NO DUCT TAPE.
DUCTWORK DIMENSIONS INDICATED ON PLANS ARE INSIDE CLEAR.
DUCTWORK SHALL CONFORM TO ASHRAE GUIDE STANDARDS AND RECOMMENDED PRACTICE OF SMACNA.DUCTWORK AND MATERIALS USED WITH DUCTWORK SHALL BE GALVANIZED STEEL.
MAXIMUM FLEXIBLE SUPPLY DUCT LENGTH SHALL BE 5'-0".NO FLEXIBLE DUCT ALLOWABLE FOR RETURN / EXHAUST / INTAKE.
8.
10.
9.
7.
5.
6.
4.
3.
2.
Mechanical Notes1.
11.
HVAC DRAWINGS ARE DIAGRAMMATIC IN NATURE AND REPRESENT CONCEPTUAL ROUTING ONLY.CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL CONDITIONS.
PROVIDE AND INSTALL NECESSARY DUCTWORK TRANSITIONS AND PIPING INCREASERS AND REDUCERS ASREQUIRED FOR EQUIPMENT CONNECTIONS. CONSULT MANUFACTURER'S DATA FOR ACTUAL DUCTWORKCONNNECTION SIZES. PROVIDE FLEXIBLE CONNECTIONS BETWEEN DUCTWORK AND FURNACES AND BETWEENDUCTWORK AND EXHAUST FANS.
PRIOR TO FABRICATION OF DUCTWORK, VERIFY, CONFIRM AND COORDINATE DUCT AND PIPE ROUTING ANDSIZES FOR ADEQUATE CLEARANCE WITH STRUCTURAL MEMBERS, CEILING HEIGHTS, AND WORK OF OTHERTRADES.
ALL RISES AND DROPS SHALL BE CONSTRUCTED USING 45 DEGREE RADIUS ELLS.
INSULATE ALL DUCTWORK. ALL DUCTWORK TO BE EXTERNALLY INSULATED.NO INTERNAL LINER ALLOWED, UNLESS SPECIFICALLY INDICATED.INCLUDES ALL SUPPLY / RETURN / EXHAUST / INTAKE DUCTWORK THROUGHOUT.
PROVIDE BALANCING DAMPERS IN ALL BRANCH CONNECTIONS TO MAINS.
PROVIDE TRANSITIONS BETWEEN BRANCH DUCTS AND DIFFUSER NECKS.
CHANGE FILTERS IN EACH UNIT DURING CONSTRUCTION A MINIMUM OF EVERY TWO (2) WEEKS. PROVIDE NEWFILTERS IN ALL UNITS AT FINAL COMPLETION.
PROVIDE ALL REQUIRED ITEMS AND COMPONENTS FOR PROPER SYSTEM OPERATION.
CONCEALED DUCTWORK SHOWN OR SIZED AS ROUND DUCT ON PLANS MAY BE INSTALLED ASRECTANGULAR DUCT AT CONTRACTOR'S OPTION.
AIR INTAKES ON ROOF SHALL BE A MINIMUM OF 10 FEET FROM EXHAUST FANS PLUMBING VENTS,FLUES OR OTHER SIMILAR OUTLETS.
16. TEMPERATURE SET POINT CONTROL SHALL BE LOCATED IN JANITOR CLOSET. INSTALL ATEMPERATURE SENSOR IN EACH BATHROOM AS SHOWN ON THE DRAWINGS THAT WILL SENDTEMPERATURE READING TO THE TEMPERATURE CONTROL PANEL. CONTROL PANEL SHALL AVERAGETHE SENSOR READINGS AND RESPOND ACCORDINGLY.
EXHAUST FANS SHALL BE CONTROLLED BY THE SAME MOTION SENSORS CONTROLLING THEBATHROOM LIGHTS. SEE DRAWING E-101.
17.
4x4x1/4 STEEL ANGLE BELOW
HVAC EQUIPMENT CURB.PROVIDE CROSS MEMBERS AT
DECK OPENINGS FOR DUCT
EXIST. ROOF BEAM
PRECAST CONCRETE
PLANK ROOF DECK
3/16 TYP. @
EACH END3/16
CFM
8Ø
Mechanical Legend
12 x 10
XXX R
XXX E
XXX
T
CUBIC FEET PER MINUTE
TEMPERATURE CONTROL
ROUND DUCT SIZE (DIAMETER)
RECTANGULAR DUCT SIZE(WIDTH X HEIGHT)
LAY-IN RETURN AIR GRILLE (NO. INDICATES CFM)
LAY-IN EXHAUST AIR GRILLE (NO. INDICATES CFM)
LAY-IN SUPPLY AIR DIFFUSER (NO. INDICATES CFM)"TITUS" MODEL TMS
"TITUS" MODEL PDR
MANUAL VOLUME DAMPER
TS TEMPERATURE SENSOR
Sheet
Cert
ifie
d By
Revi
sion
s
Proj
ect
No.
Chec
ked
By
Dra
wn
Dat
e
The Architect/Engineer does not define the scope ofindividual trades, subcontractors, material suppliers, orvendors. Any sheet numbering system used which identifiesdisciplines is solely for the Architect/Engineer'sconvenience, and is not intended to define asubcontractor's scope of work. Information regardingindividual trades, subcontractors, material suppliers, andvendors may be detailed, described and indicated atdifferent locations throughout these documents. Noconsideration will be given to requests for change ordersfor failure to obtain and review the complete set ofdrawings and specifications when preparing bids, prices,and quotations.
Notice
630
Wal
nut
Stre
etJe
ffer
sonv
ille,
IN 4
7130
812.
282
. 95
5481
2. 2
82.
9171
FAX
ww
w.k
over
thaw
kins
.com
KovertHawkins ArchitectsALL RIGHTS RESERVED
c
M-101
1846
.02
02/2
4/20
20
HK
HK
1 2 3 4 5 6
full size plot scale:
North
0
3rd Floor BathroomHVAC Plan
2'1/4"=1'-0" 4'
Mt. S
t. F
ranci
s, India
na
47146
Cente
r fo
r Sp
iritual
ity
Mount
Sain
t Fra
nci
s
101 S
t. A
nth
ony
Dri
ve
2020 R
etr
eat
Cente
r 3rd
Flo
or
Bat
hro
om
Renova
tions
full size plot scale:
North
0
Partial Roof Plan2'1/4"=1'-0" 4'
full size plot scale: NO SCALEM-101
1 RTU Support Framing
full size plot scale:
North
0
3rd Floor BathroomHVAC Demolition Plan
2'1/4"=1'-0" 4'
REMOVE STEAM RADIATOR. REMOVE PIPING LOOPTO BELOW FLOOR AND RECONNECT TO MAINTAINCIRCULATION FLOW FOR LOWER LEVELS.
REMOVE EXHAUST FAN
1
2
HVAC Demolition Notes
12
1
REMOVE FLEX DUCT A/C BRANCH RUNS IN THISAREA AND CAP AT MAIN DUCT
3
1
3
AutoCAD SHX Text
All information in this document is the confidential and proprietary information of KovertHawkins Architects and shall not be copied, reproduced, distributed, sold, electronically transmitted, assigned to a third party or otherwise appropriated without the prior written consent of KovertHawkins Architects. Unauthorized use is prohibited.
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
T
AutoCAD SHX Text
I
AutoCAD SHX Text
H
AutoCAD SHX Text
C
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
O
AutoCAD SHX Text
K
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
V
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AR00033675
Women
354
Women
354-A
Women
354-B
Women
354-C
Men
355
Men
355-A
Men
355-B
Men
355-C
Janitor
356
Stair
C
Corridor
353
Bedroom
351
Bedroom
352
GFI
GFI GFI
GFI
SS
E1E1
GFIGFI
GFIGFI
GFI GFIA/VA/V
V
V
V V
V
V
SS
SS
Electrical Plan Legend
AFF
UON
GFI
WP
20A 120VOLT DUPLEX RECEPTACLE (INTERIOR);16" AFF TO BOTTOM OF BOX, U.O.N.;WHITE DEVICE AND COVER PLATE ALL LOCATIONS.
FUSED DISCONNECT SWITCH;FUSE PER NAMEPLATE
JUNCTION BOX
MOTOR CONNECTION;PROVIDE CONNECTION COMPLETE
GROUND FAULT PROTECTED
WEATHERPROOFUNLESS OTHERWISE NOTED
ABOVE FINISHED FLOOR
20A 120VOLT DUPLEX RECEPTACLE (INTERIOR);44" AFF TO BOTTOM OF BOX, U.O.N.;VERIFY HEIGHT TO COORDINATE ABOVE SPLASHESWHERE LOCATED ABOVE A COUNTERTOP;WHITE DEVICE AND COVER PLATE ALL LOCATIONS.
HOMERUN
20A 120VOLT QUADPLEX RECEPTACLE (INTERIOR);16" AFF TO BOTTOM OF BOX, U.O.N.;WHITE DEVICE AND COVER PLATE ALL LOCATIONS.
20A 120VOLT QUADPLEX RECEPTACLE (INTERIOR);44" AFF TO BOTTOM OF BOX, U.O.N.;VERIFY HEIGHT TO COORDINATE ABOVE SPLASHESWHERE LOCATED ABOVE A COUNTERTOP;WHITE DEVICE AND COVER PLATE ALL LOCATIONS.
SPECIAL DEVICE OUTLET;16" AFF TO BOTTOM OF BOX, U.O.N.;VERIFY VOLTAGE, TYPE, AND LOCATION WITH EQUIPMENT PRIORTO ROUGH-IN
ELECTRICAL PANEL LOCATION;SEE PLAN FOR SPECIFIC PANEL INFORMATION
EC ELECTRICAL CONTRACTOR
EX EXISTING
S NON-FUSED DISCONNECT. 20 AMP, 120 VOLT SINGLE POLE SWITCH;IN "HANDY BOX"
Electrical KeynotesE1
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE PLUMBING CONTRACTOR EXACT LOCATION AND ROUGH IN REQUIREMENTSFOR ALL PLUMBING EQUIPMENT BEFORE ROUGH IN.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE H.V.A.C. CONTRACTOR EXACT LOCATION AND ROUGH IN REQUIREMENTS FORALL H.V.A.C. EQUIPMENT BEFORE ROUGH IN.
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND OWNER BEFORE WIRING IS TO BEGIN TO VERIFY ALLOTHER CONDITIONS SO THAT WIRING WILL NOT INTERFERE WITH THE OTHER TRADES.
ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. THEENTIRE ELECTRICAL SYSTEM SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER.
ALL MATERIALS USED IN THE WORK SHALL BE APPROVED BY THE UNDERWRITER'S LABORATORIES, INC., AND SHALL BARE THEIR LABEL.
THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, OBTAIN ALL PERMITS, INSPECTIONS, CERTIFICATES, AND LICENSE REQUIRED BY LAWFOR THE EXECUTION OF WORK TO BE PERFORMED.
ALL WIRING SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, STATE, COUNTY AND/OR LOCALJURISDICTION HAVING AUTHORITY IN THAT AREA.
ALL WIRING TO BE DESIGNED FOR 75 DEGREES CELSIUS.NO MORE THAN FOUR CURRENT CARRYING CONDUCTORS IN ANY ONE CONDUIT.
General Electrical Notes
9.
8.
7.
6.
5.
4.
3.
1.
PROVIDE GROUND CONDUCTOR IN ALL CONDUITS. SIZE PER NATIONAL ELECTRIC CODE.2.
UNLESS OTHERWISE NOTED, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS INDICATEDON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF FIRST CLASS CONSTRUCTION, AND SHALL BE THEPRODUCT OF AN ESTABLISHED AND REPUTABLE MANUFACTURER AND SHALL BE DESIGNED TO PERFORM THE SERVICE REQUIRED.
10.
PROVIDE ALL FIXTURES, HARDWARE, LAMPS, SWITCHES, SENSORS, WIRING, RELAYS, TIMERS, ACCESSORIES, ETC. AS REQUIRED FOR ACOMPLETE AND FULLY FUNCTIONING LIGHT FIXTURE INSTALLATION.
E3WALL SENSOR SWITCH SHALL CONTROLLIGHTS AND ACTIVATE THE IN-LINE EXHAUSTFAN. SEE M-101. ELECTRICAL CONTRACTORSHALL RUN CONTROL WIRING FROM SENSORSWITCH TO THE EXHAUST FAN AND MAKEFINAL CONNECTIONS
FIRE ALARM AUDIO/VISUAL DEVICE (CLG MOUNTED)
FIRE ALARM STROBE ONLY DEVICE (CLG MOUNTED)
A/V
V
CONNECT NEW FIRE ALARM A/V AND V DEVICES INTO EXISTING FIRE ALARM NOTIFICATION SYSTEM.12.
CONNECT NEW SMOKE DETECTION DEVICES INTO EXISTING FIRE ALARM NOTIFICATION SYSTEM.13.
SMOKE DETECTOR - A/C POWER + BATTERY BACK-UP(CLG MOUNTED)
S
Electrical Lighting Legend
OS1
20A 120V SINGLE POLE SWITCH;
44" AFF TO BOTTOM OF BOX, U.O.N.;WHITE DEVICE AND COVER PLATE ALL LOCATIONS.
S
OCCUPANCY SENSOR (STANDARD RANGE);CEILING-DUAL TECHNOLOGY; WHITE DEVICE;INSTALL COMPLETE AND PROGRAM AS REQUIRED;
MANUAL ON VIA SWITCH, MANUAL OFF VIA SWITCHAUTO ON VIA SENSOR, AUTO OFF VIA SENSOR TIMER
120/277V WALL SENSOR;
44" AFF TO BOTTOM OF BOX, U.O.N.;
WHITE DEVICE AND COVER PLATE ALL LOCATIONS.AUTO ON VIA SENSOR,PREDICTIVE OFF VIA SENSOR TIMER
SW
Light Fixture ScheduleDescriptionIden
A
NOTES:1. ALL EXIT AND EMERGENCY LIGHTING SHALL BE WIRED WITH A CONSTANT HOT WIRE AHEAD OF THE SWITCHING SERVING THAT AREA. AT NO TIME SHALL THIS LIGHTING BE SWITCHED.2. PROVIDE ADAPTERS AS REQUIRED FOR DEPTHS OF CONSTRUCTION AT EACH LOCATION.3. PROVIDE CORRECT TRIM AND MOUNTING AS REQUIRED FOR CONSTRUCTION TYPE AT EACH LOCATION.4. ALL LED LAMPS SHALL HAVE SYSTEM LIFE RATED TO RETAIN A MINIMUM OF 70% LIGHT OUTPUT AT 50,000 HOURS OF USE.
(L70 AT 50,000 HOURS).5. LED LAMP COLOR TEMPERATURES SHALL BE RATED AT CRI > 80.6. ALL LIGHTING TO SHALL BE 120 VOLT.
LampsMounting Fix. Watts Finish
RECESSED CEILING
LED1500 lumens
13.7
WHITE FRAME
B RECESSED CAN WITH LENS FOR WET AREA RECESSED CEILING
31.2LED3000 lumens
RECESSED CAN
WHITE FRAME
CVANITY LIGHT ABOVE WALL MOUNTED SINK WALL MOUNTED LED
2400 lumens27.9 WATTS BRUSHED NICKEL
EM-1SURFACE WALL MOUNT8'-0" A..F.F.
LED 1 WATT WHITE HOUSINGEMERGENCY:"LITHONIA" CU2-LED
DWALL SCONCE LIGHT WALL MOUNTED
EINDIRECT LIGHT BEHIND MIRROR (TOP & BOTTOM) WALL MOUNTED LED
The Architect/Engineer does not define the scope ofindividual trades, subcontractors, material suppliers, orvendors. Any sheet numbering system used which identifiesdisciplines is solely for the Architect/Engineer'sconvenience, and is not intended to define asubcontractor's scope of work. Information regardingindividual trades, subcontractors, material suppliers, andvendors may be detailed, described and indicated atdifferent locations throughout these documents. Noconsideration will be given to requests for change ordersfor failure to obtain and review the complete set ofdrawings and specifications when preparing bids, prices,and quotations.
All information in this document is the confidential and proprietary information of KovertHawkins Architects and shall not be copied, reproduced, distributed, sold, electronically transmitted, assigned to a third party or otherwise appropriated without the prior written consent of KovertHawkins Architects. Unauthorized use is prohibited.