AQP-WF 1 INTRODUCTION TO RADIUS Title V Air Permit Application New Jersey Department of Environmental Protection (December 6, 2011)
Mar 28, 2015
AQP-WF 1
INTRODUCTION TO RADIUSTitle V
Air Permit Application
New Jersey Department of Environmental Protection
(December 6, 2011)
AQP-WF 2
Air Permit Application
RADIUS software available at: http://www.state.nj.us/dep/aqpp/radius.html Use for non-confidential information
Save RADIUS application on CD and send to DEP
Helplines at: http://www.state.nj.us/dep/aqpp/contact.html
AQP-WF 3
RADIUS Forms
Used for all applications Major and Non-major facilities New and modified sources Use latest version of RADIUS
For Operating Permit Renewals with attachment at: http://www.state.nj.us/dep/aqpp/applying.html
Except Non-Technical Amendments http://www.state.nj.us/dep/aqpp/applying.html
AQP-WF 4
Confidential Information
Need two applications RADIUS to include non-confidential info only Complete Paper Application Consistent with N.J.A.C. 7:27-1
http://www.state.nj.us/dep/aqm/Sub1.pdf
Emission Info may not be confidentialAll info considered confidential until
decision of confidentiality is made
AQP-WF 5
Application InformationN.J.A.C. 7:27-1
See N.J.A.C. 7:27-1 (Definitions)Includes, but not limited to,
Facility Name and location Emission type and rate Frequency and duration of release Maximum production rate Emission estimation methods
AQP-WF 6
Pre-Application Information
Need ID# (or PI#) Use form AIMS-099A
Need PIN code Use form AIMS-099B
Forms available at: http://www.state.nj.us/dep/aqpp/applying.html
AQP-WF 7
Certification
Either electronic or paperElectronic preferred
Need PIN code Use form AIMS-099B
Paper certification at: http://www.state.nj.us/dep/aqpp/applying.html
AQP-WF 8
Application Completeness
Administrative Check Errors Warnings
Instructions To be updated soon http://www.state.nj.us/dep/aqpp/applying.html
AQP-WF 9
Additional Information
Compliance DemonstrationSubmit information electronically
whenever possible Attach files directly to RADIUS forms, or Include separately on the CD
AQP-WF 10
APPLICATION EXAMPLE
INTRODUCTION TO RADIUSTitle V
EXAMPLE OF AN EMISSION UNIT
AQP-WF 11
Example…Adding Equipment
Boiler280 MMBTU/hr heat inputFuel Burned
Natural gas #2 fuel oil (backup)
Hours of Operation: 4000 hrs/yrOne 10,000 Fuel Oil Storage Tank
AQP-WF 12
Select “file” to activate the drop down menu.To create a new application select “New” from the drop down menu.
AQP-WF 13
Adding a new source select“Title V Operating permit” from the drop down menu.
Select permitapplication
AQP-WF 14
Select “OK” to go to main menu
AQP-WF 15
Double click on “Reason for Application”
AQP-WF 16
Enter reasons + any other relevant information.
AQP-WF 17
Double click on “Facility Profile (General)
AQP-WF 18
Select “contact information” from the drop down menu
Select “Owner” from the drop down menu
AQP-WF 19
Select “Responsible Official” - mandatory
AQP-WF 20
Select “Responsible Official” - mandatory
AQP-WF 21
Double click on “Equipment Inventory”
AQP-WF 22
The application adds two pieces of equipment.Enter all required information.
AQP-WF 23
Highlight equip row and select “edit details” to open the equip detail sheet. Enter all details.
AQP-WF 24
Highlight next equip row andHighlight next equip row andselect “edit details” toselect “edit details” toopen the equip detail sheet.open the equip detail sheet.Enter all equip details.Enter all equip details.
AQP-WF 25
Double click on “Control Device Inventory”
AQP-WF 26
Control device is one RTOCanister Regenerative Thermal Oxidizer.
AQP-WF 27
Highlight control device row andselect “edit details” to open the CD detail sheet. Enter all details.
Once the CD details are completeClick “OK”
AQP-WF 28
Double click on “Emission Point Inventory”
AQP-WF 29
Enter emission point details.
AQP-WF 30
Double click “Emission Unit/Batch Process Inventory”
AQP-WF 31
Two Emission Units.
Select “Emission Unit Operating Scenarios” tab.
Select “each raw and enter the respective information”
AQP-WF 32
AQP-WF 33
Select U2 “Edit Detail”
AQP-WF 34
Emission unit 1 (U1) has two operating scenarios.Enter all information.
Double click to open CD and PT fields.
AQP-WF 35
Highlight row OS2, select “edit details” and enter data.
AQP-WF 36
Highlight row U2-OS1, select “edit details” and enter data.
AQP-WF 37
Double click “Potential to Emit”
AQP-WF 38
Select “Emission Unit” from drop down menu.
AQP-WF 39
Select “U1 Boiler” from drop down menu.
AQP-WF 40
Select “U1-OS1 & OS2 Boiler” from drop down menu.And enter the lb/hr emissions
AQP-WF 41
Select “Emission Unit 1- OS1” from drop down menu.And follow the same procedure as with U1 – OS0 before
AQP-WF 42
Select “Emission Unit 2” from drop down menu.And follow the same procedure as with U1 before
AQP-WF 43
Select “Compliance Plan”
AQP-WF 44
Select “Emission Unit” from drop down menu.
AQP-WF 45
Select “OS0” and add tons/year.
AQP-WF 46
Select “OS0” and add emissions tons/year, and rules that apply to all OSs.
AQP-WF 47
Select “OS1” and add emissions Lb/hr, and rules that apply to each OS individually.
AQP-WF 48
Select “Submit” from the drop down menu.
AQP-WF 49
Select “OK”
AQP-WF 50
The system performs an administrative check.If no “errors” are found, select “certify”.If errors are found return to fix them.
AQP-WF 51
Certification may be done electronically or manually. For this case select “Skip Electronic Certification”.
AQP-WF 52
The “Select File” dialogue box appears.
AQP-WF 53
Install CD disc in A-drive.Select “CD Disc” option from drop down menu and select “save”.Beginning “May 1, 2010” The Radius application will be the only form accepted by the Department as official one.
AQP-WF 54
Announcement confirms that the export is successful.Select “OK”. The application is complete!
AQP-WF 55
Tips
In an Emission Unit, an operating scenario can consist of multiple emission points and control devices, but only 1 piece of equipment
Insignificant sources and non-source fugitive sources are only specified for Title V operating permits
In the Emission Unit Operating Scenario screen, double-click the Control Device, Emission Point, and SCC fields to enter data
AQP-WF 56
More Tips
The File\Submit command does not electronically transfer the file to DEP Copy the file to CD-ROM and mail it to DEP Permit modifications must only include the data
that is being added or changed Don’t submit an edited version of the full permit
application Electronic code of Federal regulations -
http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&tpl=%2Findex.tpl
AQP-WF 57
QUESTIONS…?