Top Banner
PENTALIFT EQUIPMENT CORPORATION P O Box 1510 Buffalo NY U.S.A. 14240-1510 Phone (519) 763-3625 Fax (519) 763-2894 P O Box 1060 Guelph ON Canada N1H 6N1 Phone (519) 763-3625 Fax (519) 763-2894 Website: www.pentalift.com Email: [email protected] PENTALIFT EQUIPMENT CORPORATION Application: (F) Surface Installation - Dock Lift - End Installed With An Approach Ramp 1. Removable guard rails 6. Hydraulic & electrical lines in conduit 2. Access chains (two, upper and lower) 7. Wear plates and retaining cradles 3. Approach Ramp 8. Bollards (by others) 4. Remote power unit 9. Bridge plate(s) 5. Push button control on 10 ft. of cord 10. Electrical disconnect (by others) 1 2 3 4 5 6 7 9 8 10 Notice: The above is a generic application depiction drawing with generic bills of materials. Not for construction or building purposes. Not all of the components listed are included or provided by the factory. Consult factory for specific job drawings and component requirements.
4

Application: (F) Surface Installation - Dock Lift - End … Lift Surfacet Installation...Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach

Mar 29, 2018

Download

Documents

tranquynh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Application: (F) Surface Installation - Dock Lift - End … Lift Surfacet Installation...Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach

PENTALIFT EQUIPMENT CORPORATIONP O Box 1510 Buffalo NY U.S.A. 14240-1510 Phone (519) 763-3625 Fax (519) 763-2894P O Box 1060 Guelph ON Canada N1H 6N1 Phone (519) 763-3625 Fax (519) 763-2894Website: www.pentalift.com Email: [email protected]

PENTALIFT EQUIPMENT CORPORATION

Application: (F) Surface Installation - Dock Lift - End Installed With An Approach Ramp

1. Removable guard rails 6. Hydraulic & electrical lines in conduit

2. Access chains (two, upper and lower) 7. Wear plates and retaining cradles3. Approach Ramp 8. Bollards (by others)4. Remote power unit 9. Bridge plate(s)5. Push button control on 10 ft. of cord 10. Electrical disconnect (by others)

1

2

3

4

5

67

9

8 10

Notice: The above is a generic application depiction drawing with generic bills of materials. Not for construction or building purposes. Not all of the components listed are included or provided by the factory. Consult factory for specific job drawings and component requirements.

Page 2: Application: (F) Surface Installation - Dock Lift - End … Lift Surfacet Installation...Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach

PENTALIFT EQUIPMENT CORPORATIONP O Box 1510 Buffalo NY U.S.A. 14240-1510 Phone (519) 763-3625 Fax (519) 763-2894P O Box 1060 Guelph ON Canada N1H 6N1 Phone (519) 763-3625 Fax (519) 763-2894Website: www.pentalift.com Email: [email protected]

PENTALIFT EQUIPMENT CORPORATION

Application: (G) Surface Installation - Dock Lift - Side Installed - Permits Unobstructed Traffic Through Door

1. Removable guard rails 6. Hydraulic& electrical line(s) in conduit

2. Access chains (two, upper and lower) 7. Wear plates and retaining cradles3. Approach Ramp 8. Bollards (by others)4. Remote power unit 9. Bridge plate(s)5. Push button control on 10 ft. of cord 10. Electrical disconnect (by others)

1

2

Notice: The above is a generic application depiction drawing with generic bills of materials. Not for construction or building purposes. Not all of the components listed are included or provided by the factory. Consult factory for specific job drawings and component requirements.

3 4

5

6

7

9

8 10

Page 3: Application: (F) Surface Installation - Dock Lift - End … Lift Surfacet Installation...Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach

PENTALIFT EQUIPMENT CORPORATIONP O Box 1510 Buffalo NY U.S.A. 14240-1510 Phone (519) 763-3625 Fax (519) 763-2894P O Box 1060 Guelph ON Canada N1H 6N1 Phone (519) 763-3625 Fax (519) 763-2894Website: www.pentalift.com Email: [email protected]

PENTALIFT EQUIPMENT CORPORATION

Application: (H) Surface Installation - Dock Lift - End Installed With “Curb” Or Step Up Into The Facility

1. Removable guard rails 6. Hydraulic & electrical lines in conduit(s)

2. Access chains (two, upper and lower) 7. Wear plates and retaining cradles3. Approach Ramp 8. Bollards (by others)4. Remote power unit 9. Bridge plate(s)5. Push button control on 10 ft. of cord 10. Electrical disconnect (by others)

1

2

3

4

5

67

9

8 10

Step into building can be any height up to 54”.

Notice: The above is a generic application depiction drawing with generic bills of materials. Not for construction or building purposes. Not all of the components listed are included or provided by the factory. Consult factory for specific job drawings and component requirements.

Page 4: Application: (F) Surface Installation - Dock Lift - End … Lift Surfacet Installation...Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach

PENTALIFT EQUIPMENT CORPORATIONP O Box 1510 Buffalo NY U.S.A. 14240-1510 Phone (519) 763-3625 Fax (519) 763-2894P O Box 1060 Guelph ON Canada N1H 6N1 Phone (519) 763-3625 Fax (519) 763-2894Website: www.pentalift.com Email: [email protected]

PENTALIFT EQUIPMENT CORPORATION

Application: (I) Interior Surface Installation - Dock Lift - End Installed With An Approach Ramp

1. Removable guard rails 6. Hydraulic & electrical lines

2. Access chains (two, upper and lower) 7. Wear plates and retaining cradles3. Approach Ramp 8. Bollards (by others)4. Remote power unit 9. Bridge plate(s)5. Push button control on 10 ft. of cord 10. Electrical disconnect (by others)

12

3

4

567

9

8

10

Notice: The above is a generic application depiction drawing with generic bills of materials. Not for construction or building purposes. Not all of the components listed are included or provided by the factory. Consult factory for specific job drawings and component requirements.