QR NATIONAL HEXHAM TRAIN SUPPORT FACILITY SERVICES INVESTIGATION REPORT o:\301020\03465 - qr tsf (gs)\03.0 reports\03.01 civil infrastructure\services report\301020-03465-ci-rep-0001-g.doc 301017-03465: Rev F Appendix B - Dial before you dig Plans Hunter Water Jemena Telstra Optus Nextgen Ausgrid RMS
79
Embed
Appendix B - Dial before you dig Plans - Aurizon · 2019. 12. 18. · Appendix B - Dial before you dig Plans Hunter Water Jemena Telstra Optus Nextgen Ausgrid RMS . High Pressure
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
QR NATIONAL
HEXHAM TRAIN SUPPORT FACILITY
SERVICES INVESTIGATION REPORT
o:\301020\03465 - qr tsf (gs)\03.0 reports\03.01 civil infrastructure\services report\301020-03465-ci-rep-0001-g.doc
301017-03465: Rev F
Appendix B - Dial before you dig Plans
Hunter Water
Jemena
Telstra
Optus
Nextgen
Ausgrid
RMS
High Pressure Gas Coversheet (Jemena) 2011.doc
Network Protection High Pressure - Assets Affected
In reply to your enquiry, there are High Pressure Gas Mains in the vicinity of your intended work, as generally illustrated on the attached map. There may also be other mains or services at the location, as discussed in the warning below. For an explanation of the map, please see the key below. The following excavations guidelines apply: Excavation Guidelines: Prior to any excavations in this area, you must contact the High Pressure Response Coordinator on 1300 665 380. (Please note that a minimum two working days notice is required) to arrange a survey. For all works in the vicinity of High Pressure Gas Mains you must arrange for a Pipeline Technician to attend and supervise all excavations. Charges apply for attendance of any works outside the hours of 7am to 4pm, Monday to Friday (“Standard Business Hours”) and for any attendance during Standard Business Hours that is longer than 2 hours. In accordance with clause 34D(1) of the Gas Supply (Safety and Network Management) Regulation 2008 (NSW), you should be informed that all excavation, (including pot-holing by hand to confirm the location of pipes) should be performed in accordance with “Work Near Underground Assets Guideline” published in 2007 by the Work Cover Authority. A copy of this Guideline is available at: www.workcover.nsw.gov.au
Warning: The enclosed plans show the position of Jemena Gas Networks (NSW) Ltd’s underground gas mains and installations in public gazetted roads only. Individual customers’ services and services belonging to other third parties are not included on these plans. These plans have been prepared solely for the use of Jemena Gas Networks (NSW) Ltd and Jemena Asset Management Pty Ltd (together “Jemena”) and any reliance placed on these plans by you is entirely at your own risk. The plans may show the position of underground mains and installations relative to fences, buildings etc., as they existed at the time the mains etc were installed. The plans may not have been updated to take account of any subsequent change in the location or style of those features since the time at which the plans were initially prepared. Jemena makes no warranty as to the accuracy or completeness of the enclosed plans and does not assume any duty of care to you nor any responsibility for the accuracy, adequacy, suitability or completeness of the plans or for any error, omission, lack of detail, transmission failure or corruption in the information provided. Jemena does not accept any responsibility for any loss that you or anyone else may suffer in connection with the provision of these plans, however that loss may arise (including whether or not arising from the negligence of Jemena, its employees, agents, officers or contractors). The recipient of these plans must use their own care and diligence in carrying out their works and must carry out further surveys to locate services at their work site. Persons excavating or carrying out other earthworks will be held responsible for any damage caused to Jemena’s underground mains and equipment. Jemena advises that you may be required to carry out potholing by hand if required by a Pipeline Technician to confirm the location of Jemena’s main and installations. This must also be performed by you under the supervision of a Pipeline Technician and be carried out in accordance with the Working Near Underground Assets Guideline published in 2007 by Work Cover Authority
In case of Emergency Phone 131 909 (24 hours) Rebecca 93979107
Jemena Asset Management Pty Ltd ABN 53 086 013 461 for and on behalf of Jemena Gas Networks (NSW) Ltd ABN 87 003 004 322
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
ïïïïïïïï
ï
ïïïï
ïï
ïïïïïïïï
ïïïïï
ïïï
ïïïïïï ïïï
ïï
ïï
ïïï
ïïï
ïïïïïïï
Ð
Ð
MAITLAND RD (PACIFIC HW
Y)
PACIFIC HWY
CH
RIS
TIE
RD
ALD
WIC
K C
L
ANDERSON DR
IRVI
NG
ST
KEN
DAL
L ST
O'GILVIE ST
C
HICHESTER AV
HAR
TZER
PL
QUA
RTER
SES
SIO
NS R
D
NEWTON ST
NEW ENGLAND HWY
WO
ODBERRY RD
CEN
TRAL
AV
EAST
ERN
AV
OLD MAITLAND RD
SOUTHERN AV
SHAMROCK ST
RAILW
AY ST
OLD PUNT RD
GAL
L
E G HAN ST
TOMAGO RD
LAVER ICK AV
MERCHANT ST
FENWICK ST
1 2
3 4
5
Overvie
w
17/05/201225121499
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
ïïï
ïïïïïïï
ïïïïïï
ïïï
ïï
ïïïï
ïïï ï
ï
ï
ï
ï
ï
ï
ïï
Ð
THIRLMERE PDE
NEW ENGLAND HWY
ALD
WIC
K C
L
TRANWELL CL
PERCY ST
TENNYSON ST
WEINGARTNER AV
PASTON S
T
ANDERSON DR
QUA
RTER
SES
SIO
NS R
D
BURG ESS
PDE
WES
TER
N A
V
BEVERLEY CL
NORTHERN AV
SOUTHERN AV
BURB ANK CL
OLD MAITLAND RD
WO
OD
BERR
Y RD
CEN
TRAL
AV
EAST
ERN
AV
N E W EN
GL
AND
H
WY
OVE
RPA
SS
HA
LL
CR
11
1
11
1
2A
2
2
22
2
2
2
2
2
33
3
3 3
3
3
3
4
44
4
4
44
44
5
5
555 55
5
5
5 5
5
6
66
6 6
66
6
6
7A
7A
7
7
7
77
7
7
7
8
8
8 88
8
8
8
8
8
9
9 9
9 9
9
9
9
10
10 1010
1010
10 10
11
11
11
11
12
12
12
12
12
12
13
13
13
13
13
14
1414
14
14
15
15
15
15
15
15
16
16
16
17
17
17
1818
1818
18
18
18
19A
19
19
19 19
20-24
20
20
20
20
21
21
22
22
22
23
23
23
23
23
24
24
24
24
25
25
25
26
26
26
27
27
28
28
29
29
29
30
30
30
30
31
3131
33
33
34
35
35
36
37
39
40
41
42
43
45
47
4852
54
54
55
57
59
61
62
62
63
64
66
66
67
68
68
69-7172
737476 7980
81-83
84
85
86
8790A
9091
92 939596
98100104105
106 115
118
122
126
127
1 2
3
17/05/201225121499
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
ï
ï
ï
ïï
ï
ïïïïïïï
ïï
ïïïï
ï
ïï
ï
ïï
ï
ï
Ð
NEW ENGLAND HWY
OLD MAITLAND RD
WO
OD
BERR
Y RD
1
3
13
100
126
211
221
229
390
398
404
197A
1 2
3 4
17/05/201225121499
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
MAITLAND RD (PACIFIC HW
Y)
PAC
IFIC
HW
Y
NEW EN
GLAN
D H
WY
30
179
185
187
189
199
211
221
229
197A
1 2
3 4
5
17/05/201225121499
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
Ð
MAITLAND RD (PACIFIC HW
Y)
PAC
IFIC
HW
Y
MAITLAN
D R
D
(PACIFIC
HW
Y)
NEW EN
GLAN
D H
WY
OLD P UNT RD
OLD
PACIFIC
HW
Y
OL
D M
AITLAND
R
D
GA
LLEG H AN ST
TOM
AGO
RD
1
16
17
21
26-32
32
38
38
39
44
100
130
133
137
139
145
149
153
163
167171
179
185
185
187
187
189
191
209
227
230
231
239
241
244
312
338
342348
360
378
235
175
2
3 4
5
17/05/201225121499
WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans are and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.
Sequence Number: Date Generated:
For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208
SHAMROCK ST
RAILW
AY ST
OLD
MA
ITLA
ND
RD
MAITLAN
D R
D (PAC
IFIC H
WY)
MERCHA NT ST
MAITLAND RD
(PACIFIC HWY)
FENWICK ST
2
2
3
3
4
5
5
5
6
7
9-15
9
10
11
14-20
14 15
15
16
17
21
23-25
29
49-53
55
59-61
63
65
67
69
109-111
115
119
133
137
139
145
149
288
290
294
312
3 4
5
17/05/201225121499
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
PACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMP
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
PACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMPPACIFIC HWY ON RAMP
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL VISIONSTREAM. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM VISIONSTREAM PTY LTD.
1 Property Lines“property line” (PL), sometimes referred to as “building line” (BL), is the standard dimensioning reference point on all Ausgrid plans and represents property boundaries.
Typically the PL is the boundary between private property and local council’s footpath area or nature reserve. Most residential fences and office blocks are erected along the PL.
“kerb line” (KL) is less frequently referred to on Ausgrid plans, and where used will be identified clearly as KL.
Numbers listed within property boundaries should correspond to recognised “street numbers”.
Reading Ausgrid Plans COMN0119
NOTE: Distance and cover where indicated may be different to the actual position of the cables (eg: fill may have been placed at site that has changed the ground level).
On some A3 plans the “cross sections” may also be shown with a specific number (eg: FC1). This number will have an arrow pointing in the direction you will need to look for the cross-section detail (refer to figures 3 and 4).
Map: LE91231 524-24 1.14/0.69 61.7 E of Pearl Lane EPL32 524-24 1.14/0.69 57.6 E of Pearl Lane EPL
joint position(1.14m from PL, 0.69 cover)
Figure 6
4 Cable Joints and Joint Reports“cable joints” (numbered individually) and “joint reports” (attached to Ausgrid plans) can provide information relating to the relative position of Ausgrid assets, distance from the “property line” (in metres), and the depth of “cover” (in metres).
2 Datum References“datum references” identify distances (in metres) from significant features (such as corners of property boundaries) to reference points such as Ausgrid assets (eg: “conduits”,
“cables”, “joints”).
3 Cross Sections“cross sections” displayed on Ausgrid plans detail information relating to the relative position (ie: distance from the “property
line”, and the depth of “cover”) of Ausgrid assets.
“cover” is a term used to refer to the depth of cables underground.
A “cross section” leader line will be drawn indicating the location of the displayed “cable” or “conduit” information on Ausgrid plans.
The distance from “property line” (in metres) and depth of “cover” (in metres) references are displayed as; ie: 0.6 metres from PL and 0.5 metres underground).
Where distance and cover are not recorded, they will be clearly marked as “NR”.
5 Cross Section Detail Boxes“cross section” detail boxes on the sides of an Ausgrid plan are used when there is insufficient room to display “cable” and/or “conduit” information on the Ausgrid plan.
Ausgrid plans (refer to figure 7) are bordered by numeric identifiers along the top and bottom borders and alpha identifiers along the side borders.
A “cross section” leader line and annotation is drawn on the Ausgrid plan for a reference to “cable” and/or “conduit” information in the “cross section” detail boxes.
prepared solely for Ausgrid’s own planning use. They show the proposed position of such underground cables, overhead lines and structures as proposed at the time of planning and have not necessarily been corrected to take into account any changes to road widths, road levels, fences and buildings subsequent to proposed installation. Actual installations may vary from proposed installations as it may be necessary to take account of unforeseen above ground or subterranean constructions. Therefore, Ausgrid does not hold out that the design plans show more than the proposed presence or absence of its underground cables, overhead lines and structures in the street and will accept no liability for inaccuracies in the information shown on such design plans from any cause whatsoever.”
Figure 7
Figure 8
7 Proposal AreasThere are areas where underground work may have been issued for construction by Ausgrid, but details are not yet completely displayed on Ausgrid plans. In such cases a shaded “proposal
area” is displayed on the Ausgrid plan, indicating underground work may have commenced in the vicinity but is not yet complete.
In some instances cables and other assets within the shaded “proposal area” will be shown in a bright magenta colour, indicating that the proposed new work displayed within the shaded area is based on initial planning documentation.
In other instances the shaded “proposal area” itself may be shown as a blue colour, indicating that the new work displayed within the shaded area on the Ausgrid plan is yet to include details regarding final depths and dimensioning.
NOTE: In cases where these shaded “proposal areas” are displayed on Ausgrid plans.
“Ausgrid’s design plans showing the proposed position of its underground cables, overhead lines and structures have been
6 PitsUnderground “pits” are numbered on Ausgrid plans, positioned relative to the “property line” (PL), and can be found on either the footpath (nature strip) or the road (see figure 8).
Figure 9
Figure 10
3
Any further information regarding information displayed for “proposal areas” can be obtained by contacting the Ausgrid DBYD office at the number indicated on the response to your DBYD enquiry for further information.
If you notice an orange shaded area on your plan, DO NOT PROCEED with excavation. You will need to contact the Ausgrid DBYD office at the number indicated on the response to your DBYD enquiry and arrange for assistance (see figure 11).
In the Hunter region, some DBYD requests are covered by PENGUIN grid references. In such cases, the Ausgrid Plans show the grid quoted with a cross-reference to a corresponding Ausgrid (ISG) map grid (eg: PENGUIN 136B3 – DP711, where DP711 is the Ausgrid (ISG) grid) to optimise the legibility of plans due to PENGUIN grid scale.
Some Hunter plans may have transmission cables in the area, when these cables are present there will be a warning printed at the top of the plan supplied:
WARNING: If there is work in the vicinity of transmission
cables, Ausgrid must be contacted at least two weeks before
the work is due to commence (See Clause 2.3).
10 “Shifting Land Base” on Ausgrid
Distribution and Transmission PlansIn some instances, the plans supplied may indicate road or property outlines that appear to have shifted in relation to the Ausgrid assets displayed.
In such instances, always refer to the “property line” (in metres) and depth of “cover” (in metres) references displayed on the nearest relevant “cross sections” to obtain Ausgrid asset location information (see Reading Ausgrid Plans, section 3, Cross Sections for more detail).
Figure 12
Figure 13
ausgrid.com.au
Figure 11
8 Ausgrid (ISG) Map GridThe pale grey line indicates the 1:1000 Ausgrid (ISG) map grid
border.
The pale grey annotation located in the corners of the Ausgrid plan window, indicates the 1:1000 Ausgrid (ISG) map grid reference.
The 1:1000 Ausgrid (ISG) map grid border and reference on Ausgrid plans should be used when reading the “joint report” (see part 4 of this document for more detail) to accurately locate underground cables.
The buffer area shown on the plan should relate to the area requested on the original Dial Before you Dig request.
The grid index box can be used for reference where necessary (located in the bottom right corner of the Ausgrid plans), and will also indicate the buffer area shown on the plan.
9 Ausgrid “Distribution” and “Transmission”
PlansThe Ausgrid plans supplied may identify both “distribution” and “transmission” voltage assets for the area defined in the DBYD request.
In the Sydney region, the Ausgrid plans are separately labelled as “Distribution – nnnnnnn” and “Transmission – nnnnnnn”, where “nnnnnnn” refers to the DBYD sequence number quoted.
In the Hunter region, the Ausgrid plans show combined “distribution” and “transmission” voltage assets, and are clearly labelled as “Distr + Trans – nnnnnnn” where “nnnnnnn” refers to the DBYD sequence number.
Map: JS7111 2 9 10 LH09-0060 /0.80 48.4M SW OF POLE JS70048 11 12 /0.60 13 /0.60 14 /0.60 15 /0.60 16 17 28 LH09-0060 /0.90 26.9M SW OF POLE JS70048
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97E5
97E4
97E3
97F5
97F4
97F3
97G5
97G4
97G3
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
12
A
B
C
D
E
F
G
H
12
321 54
A
B
C
876 11109
11
ISG GRIDGRID
109876
D
E
F
54
G
32
H
1A0 MOCS_std_plot H_25121497_JS7111GMLA0_1.hpgl2
H_25121497_JS7111GMLA0_1.hpgl2
Page 1 of 1
JS7111GMLA0Distr + Trans - 25121497
JS711JS711
JS711 JS711
398398A
398B
SIGNAL BOX
1x150 FC
N/R---0.5
0.0 Signal Box
760.6
27.1
22.9
28.5
693.5
DIM 117.1
0.0 CL of both O
H 11kV lines
17.7 CL
EOP 60.1
EOP 52.2
0.0 Pole
27.1
0.0 Pole
SCALE 1:502
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97G5
97G4
97G3
97H5
97H4
97H3
97J5
97J4
97J3
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Map: JS7113 4 5 6 7 18 19 20 22 23 25 29 LH10-0391 4.20/0.90 2.8 N OF LOT390 N BDY
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97G7
97G6
97G5
97H7
97H6
97H5
97J7
97J6
97J5
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
12
A
B
C
D
E
F
G
H
12
321 54
A
B
C
876 11109
11
ISG GRIDGRID
109876
D
E
F
54
G
32
H
1A0 MOCS_std_plot H_25121497_JS7321GMLA0_1.hpgl2
H_25121497_JS7321GMLA0_1.hpgl2
Page 1 of 1
JS7321GMLA0Distr + Trans - 25121497
JS732JS732
JS732 JS732
312.8
407.2
460.9 STJ
468.4 STJ
5
4
SCALE 1:502
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97H12
97H11
97H10
97J12
97J11
97J10
97K12
97K11
97K10
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
12
A
B
C
D
E
F
G
H
12
321 54
A
B
C
876 11109
11
ISG GRIDGRID
109876
D
E
F
54
G
32
H
1A0 MOCS_std_plot H_25121497_JS7323GMLA0_1.hpgl2
H_25121497_JS7323GMLA0_1.hpgl2
Page 1 of 1
JS7323GMLA0Distr + Trans - 25121497
JS734JS734
JS734 JS734
320
15
153
151151
151A
9
151A
149
147
145
143
141
139
139
137
135
133
312
312
312
312
121
119
117
115
113113
312
312
312
304111
65A
PACIFIC HWY
0.8 --- 0.6
NA-----0.6
4x125 PVC
3 x 125 PVC
N/A-----0.6
0.0
0.0
35.8 BL
0.0
0.0
12.57
20.01 Projection of O
ffice
12.8
18.9
12.8
0.01.63 Projection of O
ffice
8.46
0.0
4.67
5.7
15.54 BL
10.54
11.99
31.3
0.0 BL
0.0 BL
12.04
0.0 60.04
42.06
28.5
24.3
0.0 FL
4.5
5.9
6.5
8.8 EOP
20.8
17.9 EOP18.3
17.6
25.7
27.5
1.6 3.60.7
0.0 KB
8.6 FL8.0
24.7
134.2
0.0
7.77
2.34
636.1
SCALE 1:502
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97K13
97K12
97K11
97L13
97L12
97L11
97M13
97M12
97M11
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
12
A
B
C
D
E
F
G
H
12
321 54
A
B
C
876 11109
11
ISG GRIDGRID
109876
D
E
F
54
G
32
H
1A0 MOCS_std_plot H_25121497_JS7344GMLA0_1.hpgl2
H_25121497_JS7344GMLA0_1.hpgl2
Page 1 of 1
JS7344GMLA0Distr + Trans - 25121497
JT112JT112
JT112 JT112
290
290
288288
3x125
0.8-----0.5
NR------NR
NR-----NR
3x125
na-----0.5
nr-----0.5
146.8
151.0 EO
P
174.6 EO
P
194.6
100.9
287.7 EO
P
256.0
264.0 EO
P
7.6 ~8.4 B
DY
0.0 Kerb
Most S/L are feed by underground supply.
2
3
4
5
6
7
SCALE 1:502
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97K15
97K14
97K13
97L15
97L14
97L13
97M15
97M14
97M13
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE
12
A
B
C
D
E
F
G
H
12
321 54
A
B
C
876 11109
11
ISG GRIDGRID
109876
D
E
F
54
G
32
H
1A0 MOCS_std_plot H_25121497_JT1124GMLA0_1.hpgl2
H_25121497_JT1124GMLA0_1.hpgl2
Page 1 of 1
JT1124GMLA0Distr + Trans - 25121497
JT121JT121
JT121 JT121
LOT2
59
61
59
57
55
PACIFIC HWY
CLARK ST
398.4
426.5
419.1 ST
J
421.2
437.2
0.80.0
597.50 STJ
23
1
1
SCALE 1:502
IS6
IS9
JT1 JT2
JS4 JS5
JS8JS7
IT3
WARNING
30 metres0
17 May 2012
97L16
97L15
97L14
97M16
97M15
97M14
97N16
97N15
97N14
Ausgrid's plans show the position of assets at the time of installation and may not account forsubsequent changes to road alignments, fences or buildings. The plans show no more than the presenceor absence of Ausgrid assets in the street.Persons working near electricity networks must exercise care and will be held responsible for anydamage caused.You must excavate by hand or use vacuum excavation to establish the location of Ausgrid undergroundcables and associated assets.Underground: Working near a cable may result in electric shock even if no contact is made. Any work inthe vicinity of any cable should only be performed using safe work methods developed in accordancewith the recommendations included in WorkCover Code of Practice for Excavation and WorkCover Guidefor Work Near Underground Assetsas well as recommendations of Ausgrid's Network Standard NS156.Overhead: Do not excavate near poles or towers until the stability of the foundation has been assessedby Ausgrid. Cables or earth conductors may be present close to substations, poles or towers.Workers must maintain safe approach distances and follow applicable WorkCover Codes of Practice.NOTE: You must keep this plan on site during excavation works and have on site a person trained toread this plan.
INFORMATION ON THIS PLAN ONLYVALID FOR 30 DAYS FROM ISSUE DATE