Appendix A: BLC-10/20/25 DC Models Packing List BLC-10/20/25/40/50 User Manual A-1 Appendix A: BLC-10/20/25 DC Models Packing List Description Belcom P/N Quantity BLC-10/20/25 BLC 10/20/25 1 Installation Kit, including: - Mounting clamp - Hex nut, ¼"-20 with lock - Flat washer ¼ x 16 x 1 - Slotted washer NF 10-32 GND screw - NF10-32x5/16 ST GND screw M1006INST - M100610P-010 - 609243530 - 609243517 - 609243532 - 609243549 1 2 4 4 2 1 WG assembly kit A10559 1 * Flex WG 0.96m 316160011 1 * WG flex assembly kit A11479 1 * Optional, not included in a standard kit.
28
Embed
Appendix A: BLC-10/20/25 DC Models Packing List 10_20_25_40...Appendix A: BLC-10/20/25 DC Models Packing List BLC-10/20/25/40/50 User Manual A-1 Appendix A: BLC-10/20/25 DC Models
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Appendix A: BLC-10/20/25 DC Models Packing List BLC-10/20/25/40/50 User Manual
A-1
Appendix A: BLC-10/20/25 DC Models PackingList
Description Belcom P/N Quantity
BLC-10/20/25 BLC 10/20/25 1
Installation Kit, including:
- Mounting clamp
- Hex nut, ¼"-20 with lock
- Flat washer ¼ x 16 x 1
- Slotted washer NF 10-32 GND screw
- NF10-32x5/16 ST GND screw
M1006INST
- M100610P-010
- 609243530
- 609243517
- 609243532
- 609243549
1
2
4
4
2
1
WG assembly kit A10559 1
* Flex WG 0.96m 316160011 1
* WG flex assembly kit A11479 1
* Optional, not included in a standard kit.
Appendix B: AC Models Packing List BLC-10/20/25/40/50 User Manual
B-1
Appendix B: AC Models Packing List
Description Belcom P/N Quantity
BLC 10/20/25/40/50 AC BLC 10/20/25/40/50
AC
1
Installation Kit, including:
- Plug female 3P + PE
- Sealing tape
- Cord end terminals
- Screw SCR SOC CAP ¼-20x30mm
- Flat washer ¼ x 16 x 1
- Hex nut, ¼"-20 with lock
- Shaft ¼-20x200mm
- Installation flange
- Installation spacer
- Slotted washer NF 10-32 GND screw
- NF10-32x5/16 ST GND screw
M1143INST
102150007
603999992
500100004
106243700
609243517
609243530
JM4106000
M114310P011
M114310P012
609243532
609243549
1
1
1
10
4
12
8
4
4
4
2
1
WG assembly kit A10559 1
* Flex WG 0.96m 316160011 1
* WG flex assembly kit A11479 1
* Optional, not included in a standard kit.
Appendix C: BLC-40/50 DC Packing List BLC-10/20/25/40/50 User Manual
C-1
Appendix C: BLC-40/50 DC Packing List
Description Belcom P/N Quantity
BLC-40/50 DC BLC 40/50 DC 1
Installation Kit, including:
- Plug female 4P + PE
- Sealing tape
- Cord end terminals
- Screw SCR SOC CAP ¼-20x30mm
- Flat washer ¼ x 16 x 1
- Hex Nut, ¼"-20 with lock
- Shaft ¼-20x200mm
- Installation flange
- Installation spacer
M1221INST
102150004
603999992
500100004
106243700
609243517
609243530
JM4106000
M114310P011
M114310P012
1
1
1
10
4
12
8
4
4
4
WG assembly kit A10559 1
* Flex WG 0.96m 316160011 1
* WG flex assembly kit A11479 1
* Optional, not included in a standard kit.
Appendix D: DC Power Inserter Packing List BLC-10/20/25/40/50 User Manual
D-1
Appendix D: DC Power Inserter Packing List
Description Belcom P/N Quantity
DC Power Inserter 48V 350W
Or:
DC Power Inserter 24V 150W
A1007/AC230/DC48
A1007/AC230/DC24
1
Modem cable, N Type
Or:
Modem cable, F Type
101364057
A10621
1
AC power cord 102700003 1
Ap
pen
dix
E:
Co
ntr
ol
BL
C-1
0/2
0/2
5/4
0/5
0 U
ser
Man
ual
E-1
Ap
pen
dix
E:
Co
ntr
ol
Th
is a
pp
end
ix d
escr
ibes
th
e C
on
tro
l co
nn
ecto
r fu
nct
ion
alit
y.
Pin
Na
me
In/O
ut
Fu
nct
ion
Lo
gic
Act
ion
1.
Sta
tus
Out
Fau
lt s
um
mar
y
"1"
= F
ault
Mu
te
2.
Ov
er t
emper
atu
reO
ut
Ov
er t
emper
atu
re p
rote
ctio
n *
*"1
" =
Fau
ltM
ute
3.
Tem
per
atu
re
war
nin
g
Out
Tem
per
atu
re w
arn
ing
**
"1"
= F
ault
Ind
icat
ion
on
ly
4.
Po
wer
su
pp
ly
stat
us
Out
Inte
rnal
po
wer
su
pp
ly f
ault
"1"
= F
ault
Mu
te
5.
Ref
lect
ed p
ow
erO
ut
Hig
h r
efle
cted
po
wer
"1"
= F
ault
Ind
icat
ion
on
ly
6.
* F
un
sta
tus
Out
Fan
ro
tati
on
sta
tus
"1"
= F
ault
Mu
te
7.
To
tal
fail
ure
Out
To
tal
fail
ure
"0"
= F
ault
Mu
te
8.
Tem
per
atu
re
Anal
og O
ut
Out
Tem
per
atu
re =
(1
00
0*
V-7
90
)/1
2.4
0-5
V A
nal
og
Ind
icat
ion
on
ly
9.
Mu
teIn
Mu
tes
the
BU
C"0
" =
Mu
teM
ute
10.
Ref
eren
ce i
np
ut
stat
us
Out
Ref
eren
ce t
hre
sho
ld l
imit
"1"
= F
ault
Ind
icat
ion
on
ly
11.
Ou
tpu
t fo
rwar
d p
ow
erA
nal
og
in
dic
atio
n v
olt
age,
See
ap
pen
dix
F0-5
V A
nal
og
Ind
icat
ion
on
ly
12.
Ou
tpu
t re
flec
ted
po
wer
An
alo
g i
nd
icat
ion
vo
ltag
e, S
ee a
pp
end
ix F
0-5
V A
nal
og
Ind
icat
ion
on
ly
13.
GN
D
* F
or
BL
C-4
0 a
nd
BL
C-5
0 m
od
els,
sta
rtin
g f
rom
S/N
20
0.
** B
UC
s w
ith M
&C
only
Appendix F: Detectors Calibration Tables BLC-10/20/25/40/50 User Manual
F-1
Appendix F: Detectors Calibration Tables
BLC-40/50 BLC-20/25
Forward power Reflected power Forward power Reflected power
Vin [volt] P [dBm] Vin [volt] P [dBm] Vin [volt] P [dBm] Vin [volt] P [dBm]
0 2 0 0 0 0 0 0
0.25 18 0.25 0 0.25 16 0.25 0
0.5 25 0.5 0 0.5 23 0.5 0
0.75 29 0.75 0 0.75 27 0.75 0
1 31 1 0 1 29 1 0
1.25 32 1.25 0 1.25 30 1.25 15
1.5 34 1.5 0 1.5 32 1.5 15
1.75 37 1.75 15 1.75 35 1.75 15
2 40 2 15 2 38 2 15
2.25 40 2.25 15 2.25 38 2.25 15
2.5 42 2.5 32 2.5 40 2.5 28
2.75 42 2.75 34 2.75 40 2.75 30
3 43 3 35 3 41 3 32
3.25 44 3.25 36 3.25 42 3.25 32
3.5 45 3.5 37 3.5 43 3.5 33
3.75 45 3.75 37 3.75 43 3.75 33
4 46 4 38 4 44 4 34
4.25 46 4.25 38 4.25 44 4.25 34
4.5 47 4.5 39 4.5 45 4.5 35
4.75 48 4.75 40 4.75 46 4.75 38
5 49 5 41 5 47 5 38
Appendix G: BLC-40/50 DC Cable Assembly BLC-10/20/25/40/50 User Manual
G-1
Appendix G: BLC-40/50 DC Cable Assembly
Part Number: 1221DCABLE
# Name Description MFG Manufacturer P/N Belcom P/N QTY
1. DC connector Plug male 4P+PE
OD 10-12mm
Binder 99-0710-02-05 102150004 1
2. AC cable* Cable AC 4x2.5mm
OD=11.5mm
LAPP GROUP OLFLEX®
ROBUST 200
0021812G
OR Equivalent
613999019 As required
3. End terminal Cord end terminal
D=2.6mm L=7mm
KST
(K.S.Terminals)
EN2507 OR
Equivalent
500100004 10
4. Sealing tape Sealing tape Le Mark RT24BLACK 603999992 1 Meter
* Not supplied
Assembly:
BLC-10/20/25/40/50 User Manual Appendix G: BLC-40/50 DC Cable Assembly
G-2
1. Seal the pins and seal the plug insert using RTV.
2. Make a sealing test.
3. Strip 40 mm from both sides of the DC Cable outer sleeve.
4. Strip 8 mm of insulation from every wire end.
5. Using a proper crimping tool, crimp the cord end terminals (supplied) on the wire stripped
tips (four on each cable side).
6. Insert the cable through the connector record parts (1a, 1b, 1c, 1d).
7. At the connector side, insert each wire end terminal to the proper connector contact
according to the schematics below.
8. Tight all terminal screws.
9. Assemble the connector. Tight the cable sleeve (1a) and pressing screw (1d) in order to
assure sealing.
10. After connecting to the BUC, wrap the sealing tape around both the cable and the mating
connector.
Schematics: (Cords color are valid for the recommended cable)
3
2
1
4
Connector
Negative (-), Black
~PE (Protective Earth) , Yellow&Green
Spare, Gray
Positive (+), Brown
Spare
Appendix H: AC Cable Assembly - L-Shape Plug BLC-10/20/25/40/50 User Manual
H-1
Appendix H: AC Cable Assembly - L-Shape Plug
Part Number: 1143LACABLE-15M
Name Description MFG Manufacturer P/N Belcom P/N QTY
1. AC
connector
Plug female 3P+PE
L shape Cable OD =
6-8 mm
Binder 99-4222-70-04 102150019 1
2. AC cable* Cable AC 3x1.5mm
OD=6.8mm
LAPP GROUP OLFLEX® ROBUST
210 0021929G
or Equivalent
613999023 As
required
3. End
terminal
Cord end terminal
D=2.6mm L=7mm
KST
(K.S.Terminals)
EN2507 or
Equivalent
500100004 10
4. Sealing tape Sealing tape Le Mark RT24BLACK 603999992 1 Meter
*Not supplied
Assembly:
BLC-10/20/25/40/50 User Manual Appendix H: AC Cable Assembly - L-Shape Plug
H-2
1. Strip 40 mm from both sides of the AC Cable outer sleeve.
2. Strip 8 mm of insulation from every wire’s end.
3. Using a proper crimping tool, crimp the cord end terminals (supplied) on the wire stripped
tips (four on each cable side).
4. Insert the cable through the connector record parts (1a, 1b, 1c, 1d).
5. At the connector side, insert each wire end terminal to the proper connector contact
according to the schematics below.
6. Fasten all terminal screws.
7. In order to assure water drainage, the cable clamp should be pointed down when the plug is
connected to the BUC. Rotate the clamp to the right direction before tightening the cable
sleeve (1a) and pressing screw (1d). Assure sealing.
8. After connecting to the BUC, wrap the sealing tape around both the cable and the mating
connector.
CAUTION
It is recommended to seal all the connectors on the BUC (i.e. the IF cable connector,
the power supply and the M&C) using a sealing tape (such as LeMark PN RT24 or
equivalent, see Figure 2-6).
Schematics: (Cords color are valid for the recommended cable)
Appendix I: AC Cable Assembly - Straight Plug BLC-10/20/25/40/50 User Manual
I-1
Appendix I: AC Cable Assembly - Straight Plug
Part Number: 1143ACABLE-15M
# Name Description MFG Manufacturer P/N Belcom P/N QTY
1. AC
connector
Plug female 3P+PE
Cable OD = 10 to
12mm
Binder 99-4222-14-04 102150007 1
2. *AC cable Cable AC 4x2.5mm
OD=11.5mm
LAPP GROUP OLFLEX® ROBUST
200 0021812G
or Equivalent
613999019 15
3. End
terminal
Cord end terminal
D=2.6mm L=7mm
KST
(K.S.Terminals)
EN2507 OR Equivalent 500100004 10
4. Sealing tape Sealing tape Le Mark RT24BLACK 603999992 1 Meter
* Not supplied
Assembly:
1. Strip 40 mm from both sides of the AC Cable outer sleeve.
2. Strip 8 mm of insulation from every wire’s end.
3. Using a proper crimping tool, crimp the cord end terminals (supplied) on the wire stripped
tips (four on each cable side).
4. Insert the cable through the connector record parts (1a, 1b, 1c, 1d).
5. At the connector side, insert each wire end terminal to the proper connector contact
according to the schematics below.
6. Tight all terminal screws.
7. Assemble the connector. Tight the cable sleeve (1a) and pressing screw (1d) in order to
assure sealing.
8. After connecting to the BUC, Wrap the sealing tape around both the cable and the mating
connector.
BLC-10/20/25/40/50 User Manual Appendix I: AC Cable Assembly - Straight Plug
I-2
CAUTION
It is recommended to seal all the connectors on the BUC (i.e. the IF cable connector,
the power supply and the M&C) using a sealing tape (such as LeMark PN RT24 or
equivalent, see Figure 2-6).
Schematics: (Cords color are valid for the recommended cable)
Appendix J: Control Cable Assembly BLC-10/20/25/40/50 User Manual
J-1
Appendix J: Control Cable Assembly
Part Number: 1006CCABLE
Name Description MFG P/N Belcom P/N Qty/Length
(m)
1. BUC control
connector
Plug 14-15 15Way Size 14
(10.57-13.7mm)
Amphenol 62IN-16J-14-
15SW
101364064 1
2. Control cable Cable Control 18x0.5mm
OD=11.8 mm
LAPP
GROUP
OLFLEX®
ROBUST 215
0022712
or equivalent
613999021 20.00
21b 1c1a
1d
BLC-10/20/25/40/50 User Manual Appendix J: Control Cable Assembly
J-2
1. Strip 30 mm of both sides of the cable.
2. Strip 5 mm of all the wire ends.
3. Plate the wire ends with solder.
4. Insert the cable through the connector shell (1a, 1b).
5. Solder the wires to the connector.
6. Connector Assembly: seal by tightening the cable holder (1c).
7. Fasten the two Phillips screws (1d).
CAUTION
It is recommended to seal all the connectors on the BUC (i.e. the IF cable connector,
the power supply and the M&C) using a sealing tape (such as LeMark PN RT24 or
equivalent, see Figure 2-6).
Schematics: (Cords color are valid for the recommended cable)
StatusA 1
Over Temp (temp mute1)B 2
Temp (temp warning1)C 3
P.S. Status (hpa ps1)D 4
Reflected PowerE 5
Fan Rotation StatusF 6
Total Failure (total1)G 7
Temp Analog OutH 8
Mute 1J 9
REF TH Status (buc1)K 10
Output Forward Power Ind.L 11
Output Reflected Power Ind.M 12
GNDN 13
GNDP 14
R 15
To BUC Control
Connector
Wire
Numbering
Yellow/Green
Appendix K: BLC-10/20/25 DC Cable Assembly BLC-10/20/25/40/50 User Manual