Discharge Measurement Summary Date Generated: Wed Jul 6 2011 File Information File Name BE062711.JAB.WAD Start Date and Time 2011/06/27 12:30:13 Site Details Site Name BEAVERCR Operator(s) JAB System Information Sensor Type FlowTracker Serial # P2091 CPU Firmware Version 3.5 Software Ver 2.20 Units (English Units) Distance ft Velocity ft/s Area ft^2 Discharge cfs Summary Averaging Int. 40 # Stations 17 Start Edge LEW Total Width 64.000 Mean SNR 24.4 dB Total Area 104.230 Mean Temp 63.84 °F Mean Depth 1.629 Disch. Equation Mid-Section Mean Velocity 0.3035 Total Discharge 31.6325 Discharge Uncertainty Category ISO Stats Accuracy 1.0% 1.0% Depth 0.1% 0.8% Velocity 0.6% 2.2% Width 0.1% 0.1% Method 2.1% - # Stations 3.0% - Overall 3.8% 2.5% Rows in italics indicate a QC warning. See the Quality Control page of this report for more information. Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q 0 12:30 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0 1 12:30 5.00 0.6 2.040 0.6 0.816 0.2241 1.00 0.2241 10.200 2.2857 7.2 2 12:32 10.00 0.6 2.160 0.6 0.864 0.2808 1.00 0.2808 10.801 3.0332 9.6 3 12:35 15.00 0.6 2.000 0.6 0.800 0.3652 1.00 0.3652 8.000 2.9213 9.2 4 13:04 18.00 0.6 1.900 0.6 0.760 0.3727 1.00 0.3727 4.750 1.7703 5.6 5 12:38 20.00 0.6 1.810 0.6 0.724 0.3540 1.00 0.3540 4.525 1.6019 5.1 6 13:07 23.00 0.6 1.720 0.6 0.688 0.3750 1.00 0.3750 4.300 1.6126 5.1 7 12:41 25.00 0.6 1.670 0.6 0.668 0.3350 1.00 0.3350 5.845 1.9579 6.2 8 12:43 30.00 0.6 1.630 0.6 0.652 0.3632 1.00 0.3632 8.150 2.9598 9.4 9 12:46 35.00 0.6 1.630 0.6 0.652 0.3346 1.00 0.3346 8.150 2.7272 8.6 10 12:48 40.00 0.6 1.620 0.6 0.648 0.3776 1.00 0.3776 8.100 3.0589 9.7 11 12:50 45.00 0.6 1.760 0.6 0.704 0.4229 1.00 0.4229 6.159 2.6048 8.2 12 13:10 47.00 0.6 1.800 0.6 0.720 0.3494 1.00 0.3494 4.500 1.5722 5.0 13 12:53 50.00 0.6 1.700 0.6 0.680 0.3058 1.00 0.3058 6.801 2.0794 6.6 14 12:55 55.00 0.6 1.620 0.6 0.648 0.1578 1.00 0.1578 8.100 1.2783 4.0 15 12:59 60.00 0.6 1.300 0.6 0.520 0.0289 1.00 0.0289 5.849 0.1689 0.5 16 12:59 64.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0 Page 1 of 4 System Report 7/6/2011 file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm
48
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE062711.JAB.WAD

Start Date and Time 2011/06/27 12:30:13

Site DetailsSite Name BEAVERCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 64.000Mean SNR 24.4 dB Total Area 104.230

Mean Temp 63.84 °F Mean Depth 1.629Disch. Equation Mid-Section Mean Velocity 0.3035

Total Discharge 31.6325

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 0.8%

Velocity 0.6% 2.2%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.0% -

Overall 3.8% 2.5%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 12:30 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 12:30 5.00 0.6 2.040 0.6 0.816 0.2241 1.00 0.2241 10.200 2.2857 7.2

2 12:32 10.00 0.6 2.160 0.6 0.864 0.2808 1.00 0.2808 10.801 3.0332 9.6

3 12:35 15.00 0.6 2.000 0.6 0.800 0.3652 1.00 0.3652 8.000 2.9213 9.2

4 13:04 18.00 0.6 1.900 0.6 0.760 0.3727 1.00 0.3727 4.750 1.7703 5.6

5 12:38 20.00 0.6 1.810 0.6 0.724 0.3540 1.00 0.3540 4.525 1.6019 5.1

6 13:07 23.00 0.6 1.720 0.6 0.688 0.3750 1.00 0.3750 4.300 1.6126 5.1

7 12:41 25.00 0.6 1.670 0.6 0.668 0.3350 1.00 0.3350 5.845 1.9579 6.2

8 12:43 30.00 0.6 1.630 0.6 0.652 0.3632 1.00 0.3632 8.150 2.9598 9.4

9 12:46 35.00 0.6 1.630 0.6 0.652 0.3346 1.00 0.3346 8.150 2.7272 8.6

10 12:48 40.00 0.6 1.620 0.6 0.648 0.3776 1.00 0.3776 8.100 3.0589 9.7

11 12:50 45.00 0.6 1.760 0.6 0.704 0.4229 1.00 0.4229 6.159 2.6048 8.2

12 13:10 47.00 0.6 1.800 0.6 0.720 0.3494 1.00 0.3494 4.500 1.5722 5.0

13 12:53 50.00 0.6 1.700 0.6 0.680 0.3058 1.00 0.3058 6.801 2.0794 6.6

14 12:55 55.00 0.6 1.620 0.6 0.648 0.1578 1.00 0.1578 8.100 1.2783 4.0

15 12:59 60.00 0.6 1.300 0.6 0.520 0.0289 1.00 0.0289 5.849 0.1689 0.5

16 12:59 64.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 2: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE062711.JAB.WAD

Start Date and Time 2011/06/27 12:30:13

Site DetailsSite Name BEAVERCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.1

0.2

0.3

0.4

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

Depth (ft)

Page 2 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 3: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE062711.JAB.WAD

Start Date and Time 2011/06/27 12:30:13

Site DetailsSite Name BEAVERCR

Operator(s) JAB

Quality Control St Loc %Dep Message

15 60.00 0.6 SNR (44.3) is different from typical SNR (24.4)

Page 3 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 4: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE062711.JAB.WAD

Start Date and Time 2011/06/27 12:30:13

Site DetailsSite Name BEAVERCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Mon Jun 27 12:24:20 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 5: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE063011.JAB.WAD

Start Date and Time 2011/06/30 14:50:41

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 19

Start Edge LEW Total Width 65.000Mean SNR 28.4 dB Total Area 104.387

Mean Temp 68.96 °F Mean Depth 1.606Disch. Equation Mid-Section Mean Velocity 0.2584

Total Discharge 26.9736

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 0.8%

Velocity 0.6% 3.2%

Width 0.1% 0.1%

Method 1.9% -

# Stations 2.6% -

Overall 3.5% 3.5%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 14:50 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 14:50 5.00 0.6 2.170 0.6 0.868 0.1352 1.00 0.1352 10.850 1.4666 5.4

2 14:54 10.00 0.6 2.350 0.6 0.940 0.2024 1.00 0.2024 11.750 2.3786 8.8

3 14:57 15.00 0.6 2.110 0.6 0.844 0.2635 1.00 0.2635 7.385 1.9455 7.2

4 15:18 17.00 0.6 2.000 0.6 0.800 0.2835 1.00 0.2835 5.000 1.4173 5.3

5 14:59 20.00 0.6 1.900 0.6 0.760 0.3406 1.00 0.3406 4.750 1.6176 6.0

6 15:20 22.00 0.6 1.770 0.6 0.708 0.2539 1.00 0.2539 4.425 1.1237 4.2

7 15:01 25.00 0.6 1.730 0.6 0.692 0.3579 1.00 0.3579 4.325 1.5481 5.7

8 15:22 27.00 0.6 1.680 0.6 0.672 0.3238 1.00 0.3238 4.200 1.3601 5.0

9 15:03 30.00 0.6 1.600 0.6 0.640 0.3422 1.00 0.3422 6.400 2.1901 8.1

10 15:04 35.00 0.6 1.640 0.6 0.656 0.3333 1.00 0.3333 5.740 1.9134 7.1

11 15:24 37.00 0.6 1.640 0.6 0.656 0.3022 1.00 0.3022 4.100 1.2389 4.6

12 15:06 40.00 0.6 1.580 0.6 0.632 0.3291 1.00 0.3291 6.320 2.0798 7.7

13 15:08 45.00 0.6 1.620 0.6 0.648 0.3553 1.00 0.3553 5.670 2.0147 7.5

14 15:25 47.00 0.6 1.620 0.6 0.648 0.2999 1.00 0.2999 4.050 1.2145 4.5

15 15:09 50.00 0.6 1.580 0.6 0.632 0.2661 1.00 0.2661 6.320 1.6817 6.2

16 15:11 55.00 0.6 1.330 0.6 0.532 0.1959 1.00 0.1959 6.650 1.3026 4.8

17 15:12 60.00 0.6 1.290 0.6 0.516 0.0745 1.00 0.0745 6.450 0.4804 1.8

18 15:12 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 6: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE063011.JAB.WAD

Start Date and Time 2011/06/30 14:50:41

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 7: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE063011.JAB.WAD

Start Date and Time 2011/06/30 14:50:41

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 8: Appendix A

Discharge Measurement Summary Date Generated: Wed Jul 6 2011

File InformationFile Name BE063011.JAB.WAD

Start Date and Time 2011/06/30 14:50:41

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Thu Jun 30 14:46:25 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/6/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 9: Appendix A

Discharge Measurement Summary Date Generated: Thu Jul 7 2011

File InformationFile Name BE070711.JAB.WAD

Start Date and Time 2011/07/07 12:10:01

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000Mean SNR 19.3 dB Total Area 99.638

Mean Temp 68.94 °F Mean Depth 1.533Disch. Equation Mid-Section Mean Velocity 0.2155

Total Discharge 21.4750

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.0%

Velocity 0.6% 2.8%

Width 0.1% 0.1%

Method 2.0% -

# Stations 3.0% -

Overall 3.8% 3.1%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 12:10 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 12:10 5.00 0.6 1.830 0.6 0.732 0.1631 1.00 0.1631 9.150 1.4920 6.9

2 12:12 10.00 0.6 2.120 0.6 0.848 0.1745 1.00 0.1745 10.600 1.8502 8.6

3 12:14 15.00 0.6 1.950 0.6 0.780 0.2467 1.00 0.2467 6.825 1.6840 7.8

4 12:32 17.00 0.6 1.840 0.6 0.736 0.2018 1.00 0.2018 4.600 0.9281 4.3

5 12:15 20.00 0.6 1.800 0.6 0.720 0.2559 1.00 0.2559 4.500 1.1515 5.4

6 12:35 22.00 0.6 1.720 0.6 0.688 0.2487 1.00 0.2487 4.300 1.0694 5.0

7 12:17 25.00 0.6 1.640 0.6 0.656 0.2352 1.00 0.2352 6.560 1.5432 7.2

8 12:19 30.00 0.6 1.520 0.6 0.608 0.2520 1.00 0.2520 7.600 1.9150 8.9

9 12:20 35.00 0.6 1.540 0.6 0.616 0.2306 1.00 0.2306 7.700 1.7760 8.3

10 12:22 40.00 0.6 1.540 0.6 0.616 0.2552 1.00 0.2552 7.700 1.9655 9.2

11 12:23 45.00 0.6 1.660 0.6 0.664 0.2956 1.00 0.2956 5.810 1.7176 8.0

12 12:37 47.00 0.6 1.660 0.6 0.664 0.2723 1.00 0.2723 4.150 1.1302 5.3

13 12:25 50.00 0.6 1.610 0.6 0.644 0.2579 1.00 0.2579 6.440 1.6606 7.7

14 12:27 55.00 0.6 1.520 0.6 0.608 0.1739 1.00 0.1739 7.600 1.3215 6.2

15 12:29 60.00 0.6 1.220 0.6 0.488 0.0443 1.00 0.0443 6.101 0.2702 1.3

16 12:29 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/7/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 10: Appendix A

Discharge Measurement Summary Date Generated: Thu Jul 7 2011

File InformationFile Name BE070711.JAB.WAD

Start Date and Time 2011/07/07 12:10:01

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% D

isch

arg

e (

%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

Velo

city

(ft

/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

Depth

(ft

)

Page 2 of 4System Report

7/7/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 11: Appendix A

Discharge Measurement Summary Date Generated: Thu Jul 7 2011

File InformationFile Name BE070711.JAB.WAD

Start Date and Time 2011/07/07 12:10:01

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

15 60.00 0.6 High SNR variation during measurement: 9.0,9.9

Page 3 of 4System Report

7/7/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 12: Appendix A

Discharge Measurement Summary Date Generated: Thu Jul 7 2011

File InformationFile Name BE070711.JAB.WAD

Start Date and Time 2011/07/07 12:10:01

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Thu Jul 7 12:07:05 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Am

plit

ude (

counts

) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/7/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 13: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 11 2011

File InformationFile Name BE070811.JAB.WAD

Start Date and Time 2011/07/08 15:22:19

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000Mean SNR 19.0 dB Total Area 100.417

Mean Temp 70.96 °F Mean Depth 1.545Disch. Equation Mid-Section Mean Velocity 0.2256

Total Discharge 22.6575

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.2%

Velocity 0.6% 2.8%

Width 0.1% 0.1%

Method 2.0% -

# Stations 3.0% -

Overall 3.8% 3.2%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 15:22 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 15:23 5.00 0.6 1.850 0.6 0.740 0.1532 1.00 0.1532 9.250 1.4173 6.3

2 15:25 10.00 0.6 2.140 0.6 0.856 0.1765 1.00 0.1765 10.700 1.8887 8.3

3 15:26 15.00 0.6 1.930 0.6 0.772 0.2651 1.00 0.2651 6.755 1.7908 7.9

4 15:45 17.00 0.6 1.850 0.6 0.740 0.2500 1.00 0.2500 4.625 1.1563 5.1

5 15:28 20.00 0.6 1.750 0.6 0.700 0.2641 1.00 0.2641 4.375 1.1555 5.1

6 15:47 22.00 0.6 1.750 0.6 0.700 0.2569 1.00 0.2569 4.375 1.1239 5.0

7 15:29 25.00 0.6 1.630 0.6 0.652 0.2717 1.00 0.2717 6.520 1.7711 7.8

8 15:31 30.00 0.6 1.560 0.6 0.624 0.2749 1.00 0.2749 7.800 2.1445 9.5

9 15:32 35.00 0.6 1.600 0.6 0.640 0.2238 1.00 0.2238 8.000 1.7901 7.9

10 15:34 40.00 0.6 1.520 0.6 0.608 0.2717 1.00 0.2717 7.600 2.0646 9.1

11 15:36 45.00 0.6 1.710 0.6 0.684 0.3412 1.00 0.3412 5.985 2.0421 9.0

12 15:49 47.00 0.6 1.700 0.6 0.680 0.2930 1.00 0.2930 4.250 1.2453 5.5

13 15:37 50.00 0.6 1.670 0.6 0.668 0.2684 1.00 0.2684 6.680 1.7927 7.9

14 15:39 55.00 0.6 1.500 0.6 0.600 0.1398 1.00 0.1398 7.500 1.0482 4.6

15 15:43 60.00 0.6 1.200 0.6 0.480 0.0377 1.00 0.0377 6.001 0.2264 1.0

16 15:43 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/11/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 14: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 11 2011

File InformationFile Name BE070811.JAB.WAD

Start Date and Time 2011/07/08 15:22:19

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

Depth (ft)

Page 2 of 4System Report

7/11/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 15: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 11 2011

File InformationFile Name BE070811.JAB.WAD

Start Date and Time 2011/07/08 15:22:19

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

15 60.00 0.6 High SNR variation during measurement: 6.0,6.0

Page 3 of 4System Report

7/11/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 16: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 11 2011

File InformationFile Name BE070811.JAB.WAD

Start Date and Time 2011/07/08 15:22:19

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Fri Jul 8 15:20:38 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/11/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 17: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 18 2011

File InformationFile Name BE071811.JAB.WAD

Start Date and Time 2011/07/18 12:03:34

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 16

Start Edge LEW Total Width 65.000Mean SNR 17.3 dB Total Area 99.451

Mean Temp 69.73 °F Mean Depth 1.530Disch. Equation Mid-Section Mean Velocity 0.1712

Total Discharge 17.0275

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.0%

Velocity 0.7% 3.1%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.1% -

Overall 4.0% 3.4%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 12:03 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 12:03 5.00 0.6 1.900 0.6 0.760 0.1145 1.00 0.1145 9.500 1.0877 6.4

2 12:05 10.00 0.6 2.100 0.6 0.840 0.1414 1.00 0.1414 10.500 1.4848 8.7

3 12:06 15.00 0.6 1.910 0.6 0.764 0.1732 1.00 0.1732 9.551 1.6544 9.7

4 12:08 20.00 0.6 1.800 0.6 0.720 0.1814 1.00 0.1814 8.999 1.6328 9.6

5 12:10 25.00 0.6 1.620 0.6 0.648 0.1683 1.00 0.1683 8.100 1.3634 8.0

6 12:11 30.00 0.6 1.520 0.6 0.608 0.2149 1.00 0.2149 7.600 1.6332 9.6

7 12:13 35.00 0.6 1.540 0.6 0.616 0.1781 1.00 0.1781 7.700 1.3718 8.1

8 12:15 40.00 0.6 1.510 0.6 0.604 0.2047 1.00 0.2047 7.549 1.5455 9.1

9 12:16 45.00 0.6 1.680 0.6 0.672 0.2828 1.00 0.2828 5.880 1.6630 9.8

10 12:25 47.00 0.6 1.680 0.6 0.672 0.2533 1.00 0.2533 4.200 1.0639 6.2

11 12:19 50.00 0.6 1.600 0.6 0.640 0.2139 1.00 0.2139 4.000 0.8557 5.0

12 12:27 52.00 0.6 1.580 0.6 0.632 0.1821 1.00 0.1821 3.950 0.7193 4.2

13 12:21 55.00 0.6 1.480 0.6 0.592 0.1306 1.00 0.1306 5.920 0.7730 4.5

14 12:23 60.00 0.6 1.200 0.6 0.480 0.0299 1.00 0.0299 6.001 0.1792 1.1

15 12:23 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/18/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 18: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 18 2011

File InformationFile Name BE071811.JAB.WAD

Start Date and Time 2011/07/18 12:03:34

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

Depth (ft)

Page 2 of 4System Report

7/18/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 19: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 18 2011

File InformationFile Name BE071811.JAB.WAD

Start Date and Time 2011/07/18 12:03:34

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

7/18/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 20: Appendix A

Discharge Measurement Summary Date Generated: Mon Jul 18 2011

File InformationFile Name BE071811.JAB.WAD

Start Date and Time 2011/07/18 12:03:34

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Mon Jul 18 12:01:45 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/18/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 21: Appendix A

Discharge Measurement Summary Date Generated: Tue Jul 19 2011

File InformationFile Name BE071911.JAB.WAD

Start Date and Time 2011/07/19 16:14:40

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 16

Start Edge LEW Total Width 65.000Mean SNR 37.2 dB Total Area 112.794

Mean Temp 74.06 °F Mean Depth 1.735Disch. Equation Mid-Section Mean Velocity 0.6296

Total Discharge 71.0178

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.4%

Velocity 0.7% 1.8%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.1% -

Overall 4.0% 2.5%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 16:14 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 16:14 5.00 0.6 2.130 0.6 0.852 0.4918 1.00 0.4918 10.650 5.2375 7.4

2 16:16 10.00 0.6 2.400 0.6 0.960 0.5479 1.00 0.5479 12.000 6.5746 9.3

3 16:17 15.00 0.6 2.220 0.6 0.888 0.6726 1.00 0.6726 7.771 5.2262 7.4

4 16:37 17.00 0.6 2.150 0.6 0.860 0.7211 1.00 0.7211 5.375 3.8759 5.5

5 16:19 20.00 0.6 2.050 0.6 0.820 0.7388 1.00 0.7388 8.199 6.0581 8.5

6 16:21 25.00 0.6 1.900 0.6 0.760 0.7123 1.00 0.7123 9.500 6.7663 9.5

7 16:22 30.00 0.6 1.810 0.6 0.724 0.7513 1.00 0.7513 9.050 6.7995 9.6

8 16:24 35.00 0.6 1.800 0.6 0.720 0.6972 1.00 0.6972 8.999 6.2741 8.8

9 16:25 40.00 0.6 1.800 0.6 0.720 0.7687 1.00 0.7687 8.999 6.9178 9.7

10 16:27 45.00 0.6 1.900 0.6 0.760 0.7608 1.00 0.7608 6.650 5.0593 7.1

11 16:39 47.00 0.6 1.900 0.6 0.760 0.7493 1.00 0.7493 4.750 3.5593 5.0

12 16:29 50.00 0.6 1.850 0.6 0.740 0.5978 1.00 0.5978 7.400 4.4236 6.2

13 16:31 55.00 0.6 1.740 0.6 0.696 0.4541 1.00 0.4541 8.701 3.9508 5.6

14 16:34 60.00 0.6 0.950 0.6 0.380 0.0620 1.00 0.0620 4.751 0.2946 0.4

15 16:34 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

7/19/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 22: Appendix A

Discharge Measurement Summary Date Generated: Tue Jul 19 2011

File InformationFile Name BE071911.JAB.WAD

Start Date and Time 2011/07/19 16:14:40

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.2

0.4

0.6

0.8

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

7/19/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 23: Appendix A

Discharge Measurement Summary Date Generated: Tue Jul 19 2011

File InformationFile Name BE071911.JAB.WAD

Start Date and Time 2011/07/19 16:14:40

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

7/19/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 24: Appendix A

Discharge Measurement Summary Date Generated: Tue Jul 19 2011

File InformationFile Name BE071911.JAB.WAD

Start Date and Time 2011/07/19 16:14:40

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Tue Jul 19 16:12:47 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

7/19/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 25: Appendix A

Discharge Measurement Summary Date Generated: Thu Aug 4 2011

File InformationFile Name BE080311.JAB.WAD

Start Date and Time 2011/08/03 14:21:22

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000Mean SNR 23.5 dB Total Area 107.473

Mean Temp 71.47 °F Mean Depth 1.653Disch. Equation Mid-Section Mean Velocity 0.4050

Total Discharge 43.5302

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.3%

Velocity 0.6% 2.8%

Width 0.1% 0.1%

Method 2.0% -

# Stations 3.0% -

Overall 3.8% 3.2%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 14:21 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 14:21 5.00 0.6 2.050 0.6 0.820 0.3153 1.00 0.3153 10.249 3.2315 7.4

2 14:22 10.00 0.6 2.340 0.6 0.936 0.2802 1.00 0.2802 11.699 3.2780 7.5

3 14:24 15.00 0.6 2.020 0.6 0.808 0.4491 1.00 0.4491 7.070 3.1755 7.3

4 14:43 17.00 0.6 2.000 0.6 0.800 0.4879 1.00 0.4879 5.000 2.4393 5.6

5 14:25 20.00 0.6 1.810 0.6 0.724 0.5256 1.00 0.5256 4.525 2.3783 5.5

6 14:46 22.00 0.6 1.730 0.6 0.692 0.4993 1.00 0.4993 4.325 2.1596 5.0

7 14:27 25.00 0.6 1.690 0.6 0.676 0.4764 1.00 0.4764 6.760 3.2202 7.4

8 14:28 30.00 0.6 1.670 0.6 0.668 0.5118 1.00 0.5118 8.350 4.2735 9.8

9 14:30 35.00 0.6 1.650 0.6 0.660 0.4938 1.00 0.4938 8.250 4.0734 9.4

10 14:31 40.00 0.6 1.670 0.6 0.668 0.4754 1.00 0.4754 8.350 3.9694 9.1

11 14:33 45.00 0.6 1.770 0.6 0.708 0.5413 1.00 0.5413 6.195 3.3536 7.7

12 14:48 47.00 0.6 1.800 0.6 0.720 0.5023 1.00 0.5023 4.500 2.2602 5.2

13 14:35 50.00 0.6 1.700 0.6 0.680 0.5115 1.00 0.5115 6.801 3.4784 8.0

14 14:37 55.00 0.6 1.690 0.6 0.676 0.2205 1.00 0.2205 8.450 1.8629 4.3

15 14:40 60.00 0.6 1.390 0.6 0.556 0.0541 1.00 0.0541 6.950 0.3763 0.9

16 14:40 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

8/4/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 26: Appendix A

Discharge Measurement Summary Date Generated: Thu Aug 4 2011

File InformationFile Name BE080311.JAB.WAD

Start Date and Time 2011/08/03 14:21:22

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.1

0.2

0.3

0.4

0.5

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

8/4/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 27: Appendix A

Discharge Measurement Summary Date Generated: Thu Aug 4 2011

File InformationFile Name BE080311.JAB.WAD

Start Date and Time 2011/08/03 14:21:22

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

8/4/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 28: Appendix A

Discharge Measurement Summary Date Generated: Thu Aug 4 2011

File InformationFile Name BE080311.JAB.WAD

Start Date and Time 2011/08/03 14:21:22

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Wed Aug 3 14:19:27 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

8/4/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 29: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE080911.JAB.WAD

Start Date and Time 2011/08/09 14:10:33

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000Mean SNR 23.5 dB Total Area 105.011

Mean Temp 72.42 °F Mean Depth 1.616Disch. Equation Mid-Section Mean Velocity 0.3439

Total Discharge 36.1130

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.2%

Velocity 0.6% 2.9%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.0% -

Overall 3.8% 3.3%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 14:10 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 14:10 5.00 0.6 1.980 0.6 0.792 0.2208 1.00 0.2208 9.900 2.1859 6.1

2 14:12 10.00 0.6 2.290 0.6 0.916 0.2549 1.00 0.2549 11.450 2.9189 8.1

3 14:13 15.00 0.6 2.000 0.6 0.800 0.3973 1.00 0.3973 7.000 2.7812 7.7

4 14:30 17.00 0.6 1.900 0.6 0.760 0.4039 1.00 0.4039 4.750 1.9183 5.3

5 14:15 20.00 0.6 1.820 0.6 0.728 0.3963 1.00 0.3963 4.550 1.8032 5.0

6 14:32 22.00 0.6 1.750 0.6 0.700 0.4560 1.00 0.4560 4.375 1.9952 5.5

7 14:17 25.00 0.6 1.690 0.6 0.676 0.4518 1.00 0.4518 6.760 3.0539 8.5

8 14:18 30.00 0.6 1.670 0.6 0.668 0.4304 1.00 0.4304 5.845 2.5159 7.0

9 14:33 32.00 0.6 1.700 0.6 0.680 0.4521 1.00 0.4521 4.250 1.9216 5.3

10 14:19 35.00 0.6 1.620 0.6 0.648 0.3967 1.00 0.3967 6.480 2.5704 7.1

11 14:21 40.00 0.6 1.600 0.6 0.640 0.4400 1.00 0.4400 8.000 3.5198 9.7

12 14:23 45.00 0.6 1.700 0.6 0.680 0.3921 1.00 0.3921 8.501 3.3328 9.2

13 14:25 50.00 0.6 1.730 0.6 0.692 0.4157 1.00 0.4157 8.650 3.5956 10.0

14 14:26 55.00 0.6 1.600 0.6 0.640 0.2260 1.00 0.2260 8.000 1.8085 5.0

15 14:28 60.00 0.6 1.300 0.6 0.520 0.0295 1.00 0.0295 6.499 0.1919 0.5

16 14:28 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 30: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE080911.JAB.WAD

Start Date and Time 2011/08/09 14:10:33

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.1

0.2

0.3

0.4

0.5

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 31: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE080911.JAB.WAD

Start Date and Time 2011/08/09 14:10:33

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

15 60.00 0.60.6

SNR (41.9) is different from typical SNR (23.5) High SNR variation during measurement: 4.3,5.6

Page 3 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 32: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE080911.JAB.WAD

Start Date and Time 2011/08/09 14:10:33

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Tue Aug 9 14:09:11 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 33: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE082511.JAB.WAD

Start Date and Time 2011/08/25 16:19:08

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 18

Start Edge LEW Total Width 65.000Mean SNR 22.5 dB Total Area 97.674

Mean Temp 71.13 °F Mean Depth 1.503Disch. Equation Mid-Section Mean Velocity 0.1527

Total Discharge 14.9154

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.2%

Velocity 0.6% 2.3%

Width 0.1% 0.1%

Method 2.0% -

# Stations 2.8% -

Overall 3.6% 2.8%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 16:19 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 16:19 5.00 0.6 1.820 0.6 0.728 0.0489 1.00 0.0489 9.099 0.4448 3.0

2 16:20 10.00 0.6 2.100 0.6 0.840 0.0984 1.00 0.0984 10.500 1.0335 6.9

3 16:22 15.00 0.6 1.850 0.6 0.740 0.1814 1.00 0.1814 6.475 1.1748 7.9

4 16:45 17.00 0.6 1.800 0.6 0.720 0.1611 1.00 0.1611 4.500 0.7248 4.9

5 16:24 20.00 0.6 1.740 0.6 0.696 0.1713 1.00 0.1713 6.961 1.1921 8.0

6 16:25 25.00 0.6 1.520 0.6 0.608 0.2064 1.00 0.2064 5.320 1.0979 7.4

7 16:47 27.00 0.6 1.510 0.6 0.604 0.2051 1.00 0.2051 3.775 0.7740 5.2

8 16:26 30.00 0.6 1.520 0.6 0.608 0.2215 1.00 0.2215 4.560 1.0099 6.8

9 16:49 33.00 0.6 1.580 0.6 0.632 0.2057 1.00 0.2057 3.950 0.8126 5.4

10 16:28 35.00 0.6 1.500 0.6 0.600 0.2165 1.00 0.2165 5.250 1.1368 7.6

11 16:29 40.00 0.6 1.490 0.6 0.596 0.2073 1.00 0.2073 5.961 1.2359 8.3

12 16:51 43.00 0.6 1.510 0.6 0.604 0.2274 1.00 0.2274 3.775 0.8582 5.8

13 16:31 45.00 0.6 1.600 0.6 0.640 0.2211 1.00 0.2211 5.600 1.2384 8.3

14 16:33 50.00 0.6 1.670 0.6 0.668 0.1434 1.00 0.1434 8.350 1.1971 8.0

15 16:37 55.00 0.6 1.510 0.6 0.604 0.1007 1.00 0.1007 7.549 0.7604 5.1

16 16:43 60.00 0.6 1.210 0.6 0.484 0.0371 1.00 0.0371 6.050 0.2243 1.5

17 16:43 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 34: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE082511.JAB.WAD

Start Date and Time 2011/08/25 16:19:08

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.00

0.05

0.10

0.15

0.20

0.25

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

Depth (ft)

Page 2 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 35: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE082511.JAB.WAD

Start Date and Time 2011/08/25 16:19:08

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

1 5.00 0.60.6

SNR (33.5) is different from typical SNR (22.5) High SNR variation during measurement: 9.0,9.9

16 60.00 0.60.6

High angle: 24 Boundary QC is Good; possible boundary interference

Page 3 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 36: Appendix A

Discharge Measurement Summary Date Generated: Fri Aug 26 2011

File InformationFile Name BE082511.JAB.WAD

Start Date and Time 2011/08/25 16:19:08

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Thu Aug 25 16:17:29 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

8/26/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 37: Appendix A

Discharge Measurement Summary Date Generated: Wed Sep 28 2011

File InformationFile Name BE092711.JAB.WAD

Start Date and Time 2011/09/27 11:18:07

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTrackerSerial # P2091

CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ftVelocity ft/s

Area ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000Mean SNR 28.8 dB Total Area 112.162

Mean Temp 59.49 °F Mean Depth 1.726Disch. Equation Mid-Section Mean Velocity 0.5232

Total Discharge 58.6875

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.1%

Velocity 0.7% 3.2%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.0% -

Overall 3.8% 3.5%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 11:18 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 11:18 5.00 0.6 2.100 0.6 0.840 0.3655 1.00 0.3655 10.500 3.8377 6.5

2 11:20 10.00 0.6 2.410 0.6 0.964 0.4629 1.00 0.4629 12.051 5.5785 9.5

3 11:21 15.00 0.6 2.100 0.6 0.840 0.6850 1.00 0.6850 7.350 5.0352 8.6

4 11:44 17.00 0.6 2.050 0.6 0.820 0.6949 1.00 0.6949 5.125 3.5610 6.1

5 11:24 20.00 0.6 1.900 0.6 0.760 0.6726 1.00 0.6726 4.750 3.1946 5.4

6 11:46 22.00 0.6 1.840 0.6 0.736 0.6155 1.00 0.6155 4.600 2.8311 4.8

7 11:26 25.00 0.6 1.780 0.6 0.712 0.6470 1.00 0.6470 7.119 4.6061 7.8

8 11:29 30.00 0.6 1.740 0.6 0.696 0.6289 1.00 0.6289 8.701 5.4722 9.3

9 11:30 35.00 0.6 1.740 0.6 0.696 0.5643 1.00 0.5643 8.701 4.9099 8.4

10 11:32 40.00 0.6 1.780 0.6 0.712 0.5591 1.00 0.5591 7.119 3.9802 6.8

11 11:48 43.00 0.6 1.780 0.6 0.712 0.4764 1.00 0.4764 4.450 2.1197 3.6

12 11:36 45.00 0.6 1.870 0.6 0.748 0.6696 1.00 0.6696 6.545 4.3828 7.5

13 11:38 50.00 0.6 1.810 0.6 0.724 0.5883 1.00 0.5883 9.050 5.3238 9.1

14 11:39 55.00 0.6 1.730 0.6 0.692 0.4114 1.00 0.4114 8.650 3.5587 6.1

15 11:42 60.00 0.6 1.490 0.6 0.596 0.0397 1.00 0.0397 7.451 0.2958 0.5

16 11:42 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

9/28/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 38: Appendix A

Discharge Measurement Summary Date Generated: Wed Sep 28 2011

File InformationFile Name BE092711.JAB.WAD

Start Date and Time 2011/09/27 11:18:07

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

9/28/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 39: Appendix A

Discharge Measurement Summary Date Generated: Wed Sep 28 2011

File InformationFile Name BE092711.JAB.WAD

Start Date and Time 2011/09/27 11:18:07

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

9/28/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 40: Appendix A

Discharge Measurement Summary Date Generated: Wed Sep 28 2011

File InformationFile Name BE092711.JAB.WAD

Start Date and Time 2011/09/27 11:18:07

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Tue Sep 27 11:16:10 EDT 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

9/28/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 41: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111411.JAB.WAD

Start Date and Time 2011/11/14 15:19:13

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTracker

Serial # P2091CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ft

Velocity ft/sArea ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 17

Start Edge LEW Total Width 65.000

Mean SNR 30.2 dB Total Area 118.926Mean Temp 55.53 °F Mean Depth 1.830

Disch. Equation Mid-Section Mean Velocity 0.6976 Total Discharge 82.9664

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 1.2%

Velocity 0.7% 1.5%

Width 0.1% 0.1%

Method 2.1% -

# Stations 3.0% -

Overall 3.8% 2.1%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 15:19 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 15:20 5.00 0.6 2.150 0.6 0.860 0.2785 1.00 0.2785 10.750 2.9942 3.6

2 15:23 10.00 0.6 2.480 0.6 0.992 0.6093 1.00 0.6093 12.400 7.5547 9.1

3 15:24 15.00 0.6 2.240 0.6 0.896 0.7395 1.00 0.7395 7.841 5.7981 7.0

4 15:51 17.00 0.6 2.140 0.6 0.856 0.7995 1.00 0.7995 5.350 4.2777 5.2

5 15:26 20.00 0.6 2.020 0.6 0.808 0.8196 1.00 0.8196 8.080 6.6220 8.0

6 15:27 25.00 0.6 1.890 0.6 0.756 0.8681 1.00 0.8681 9.450 8.2040 9.9

7 15:29 30.00 0.6 1.860 0.6 0.744 0.8284 1.00 0.8284 9.300 7.7039 9.3

8 15:31 35.00 0.6 1.850 0.6 0.740 0.8136 1.00 0.8136 9.250 7.5265 9.1

9 15:33 40.00 0.6 1.810 0.6 0.724 0.8593 1.00 0.8593 9.050 7.7764 9.4

10 15:39 45.00 0.6 2.100 0.6 0.840 0.8822 1.00 0.8822 7.350 6.4845 7.8

11 15:48 47.00 0.6 2.040 0.6 0.816 0.9521 1.00 0.9521 5.100 4.8558 5.9

12 15:41 50.00 0.6 2.070 0.6 0.828 0.8543 1.00 0.8543 5.175 4.4209 5.3

13 15:46 52.00 0.6 1.980 0.6 0.792 0.7772 1.00 0.7772 4.950 3.8473 4.6

14 15:43 55.00 0.6 1.820 0.6 0.728 0.5889 1.00 0.5889 7.280 4.2870 5.2

15 15:44 60.00 0.6 1.520 0.6 0.608 0.0807 1.00 0.0807 7.600 0.6134 0.7

16 15:44 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 42: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111411.JAB.WAD

Start Date and Time 2011/11/14 15:19:13

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

10

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.2

0.4

0.6

0.8

1.0

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 43: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111411.JAB.WAD

Start Date and Time 2011/11/14 15:19:13

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

7 30.00 0.6 High SNR variation during measurement: 4.7,6.9

8 35.00 0.6 High SNR variation during measurement: 1.7,5.6

14 55.00 0.6 High SNR variation during measurement: 6.0,3.0

Page 3 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 44: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111411.JAB.WAD

Start Date and Time 2011/11/14 15:19:13

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Mon Nov 14 15:17:37 EST 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 45: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111511.JAB.WAD

Start Date and Time 2011/11/16 12:01:31

Site DetailsSite Name BEAVCR

Operator(s) JAB

System InformationSensor Type FlowTracker

Serial # P2091CPU Firmware Version 3.5

Software Ver 2.20

Units (English Units)

Distance ft

Velocity ft/sArea ft^2

Discharge cfs

SummaryAveraging Int. 40 # Stations 18

Start Edge LEW Total Width 65.000

Mean SNR 24.5 dB Total Area 120.625Mean Temp 52.93 °F Mean Depth 1.856

Disch. Equation Mid-Section Mean Velocity 0.7784 Total Discharge 93.8992

Discharge UncertaintyCategory ISO Stats

Accuracy 1.0% 1.0%

Depth 0.1% 0.9%

Velocity 0.6% 2.0%

Width 0.1% 0.1%

Method 2.0% -

# Stations 2.8% -

Overall 3.6% 2.4%

Rows in italics indicate a QC warning. See the Quality Control page of this report for more information.

Measurement Results St Clock Loc Method Depth %Dep MeasD Vel CorrFact MeanV Area Flow %Q

0 12:01 0.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

1 12:02 5.00 0.6 2.220 0.6 0.888 0.4213 1.00 0.4213 11.101 4.6763 5.0

2 12:03 10.00 0.6 2.530 0.6 1.012 0.6604 1.00 0.6604 12.649 8.3540 8.9

3 12:05 15.00 0.6 2.300 0.6 0.920 0.8586 1.00 0.8586 8.050 6.9113 7.4

4 12:29 17.00 0.6 2.160 0.6 0.864 0.8944 1.00 0.8944 5.400 4.8298 5.1

5 12:06 20.00 0.6 2.000 0.6 0.800 1.0085 1.00 1.0085 5.000 5.0427 5.4

6 12:27 22.00 0.6 1.940 0.6 0.776 0.9783 1.00 0.9783 4.850 4.7449 5.1

7 12:08 25.00 0.6 1.900 0.6 0.760 0.9521 1.00 0.9521 7.600 7.2357 7.7

8 12:09 30.00 0.6 1.890 0.6 0.756 1.0400 1.00 1.0400 6.615 6.8801 7.3

9 12:25 32.00 0.6 1.930 0.6 0.772 0.9157 1.00 0.9157 4.825 4.4184 4.7

10 12:12 35.00 0.6 1.900 0.6 0.760 0.9682 1.00 0.9682 7.600 7.3579 7.8

11 12:13 40.00 0.6 1.900 0.6 0.760 0.8930 1.00 0.8930 9.500 8.4836 9.0

12 12:14 45.00 0.6 2.010 0.6 0.804 1.0013 1.00 1.0013 7.034 7.0437 7.5

13 12:22 47.00 0.6 2.060 0.6 0.824 1.0289 1.00 1.0289 5.150 5.2988 5.6

14 12:16 50.00 0.6 2.100 0.6 0.840 0.8199 1.00 0.8199 8.400 6.8872 7.3

15 12:18 55.00 0.6 1.850 0.6 0.740 0.5846 1.00 0.5846 9.250 5.4082 5.8

16 12:20 60.00 0.6 1.520 0.6 0.608 0.0430 1.00 0.0430 7.600 0.3266 0.3

17 12:20 65.00 None 0.000 0.0 0.0 0.0000 1.00 0.0000 0.000 0.0000 0.0

Page 1 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 46: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111511.JAB.WAD

Start Date and Time 2011/11/16 12:01:31

Site DetailsSite Name BEAVCR

Operator(s) JAB

0 10 20 30 40 50 60

Location (ft)

0

2

4

6

8

% Discharge (%)

<5.0%

5.0 - 10.0%

>10.0%

0 10 20 30 40 50 60

Location (ft)

0.0

0.2

0.4

0.6

0.8

1.0

Velocity (ft/s)

0 10 20 30 40 50 60

Location (ft)

0.0

0.5

1.0

1.5

2.0

2.5

Depth (ft)

Page 2 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 47: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111511.JAB.WAD

Start Date and Time 2011/11/16 12:01:31

Site DetailsSite Name BEAVCR

Operator(s) JAB

Quality Control St Loc %Dep Message

No Quality Control warnings

Page 3 of 4System Report

11/16/2011file://C:\Program Files\SonTek\FlowTracker\Resources\Reports\Summary.htm

Page 48: Appendix A

Discharge Measurement Summary Date Generated: Wed Nov 16 2011

File InformationFile Name BE111511.JAB.WAD

Start Date and Time 2011/11/16 12:01:31

Site DetailsSite Name BEAVCR

Operator(s) JAB

Automatic Quality Control Test (BeamCheck)

Wed Nov 16 12:00:06 EST 2011

5 10 15 20 25 30 35 40

Range (cm)

0

50

100

150

200

Amplitude (counts) Beam1

Beam2

Noise level check - Pass

SNR check - Pass

Peak location check - Pass

Peak shape check - Pass

Page 4 of 4System Report