- FRANCE
- FRANCE
We make intrumentation solutions for your industrial processes
ATEX PRODUCTS
4-20mA LOOP & PROCESS
A puissance 3 company - ATEX manufacturer since 1983 - http://apuissance3.com/eng - +33.5.57.97.17.97
Self-powered indicators through the current loop 4-20 mA loop powered thermometer 22mm Ø lights probe and light column Manual setpoint generator 2-wire RTD100 or thermocouples temperature transmi�er 2-wire poten�ometer input transmi�er 2-wire pulses/rpm/flow transmi�er w/Bluetooth Temperature converters Digital thermostat Temperature probes fi�ed with 4-20 mA transmi�er4-20mA loop power supply with galvanically isolated copy Power supply for relays, contacts, solenoid valves, indicators Associated interfaces for custom sensor Self-powered or powered galvanic isola�on Explosion proof envelope indicator Cable boxes - junc�on and connec�on boxes Grounding system
4-20mA transmi�er - condi�oner - indicators 4-20 mA loop powered indicators Self-powered thermometer 4-20mA with copying Programmable indicator with calcula�on func�onsManual setpoint generator 4-20mA Loop Portable Generator 2-wire Pt100 temperature transmi�er or thermocouples 2-wire poten�ometer transmi�er Universal 4-20 mA transmi�er w/Bluetooth RTD100 / thermocouples temperature converter Poten�ometer input to 4-20mA converter Voltage input to 4-20mA converterCharge amplifier for 4-20mA loop 4-20mA loop power supply Self-powered galvanic insola�on Galvanic isola�on with external power supplyThreshold relays
Custom made enclosures, cabinets and boxesfor explosive atmosphere zone 1 & zone 2
° Zone 1 or zone 2 enclosure for pneumatic island° Filtered pressure regulator option° Remote I/O option° Stainless steel enclosure or carbon fibre reinforced polyester ° Customization fitting customer needs° 94/9/EU & 2014/34/EU compliance° Declaration of conformity supplied° ATEX validated production QA
° HMI & PLC enclosure for ATEX zone 2° Junction boxes Ex e° Connection boxes° Control boxes° Supporting arm system
Made in France
A puissance 3 company - ATEX manufacturer since 1983 - http://apuissance3.com/eng - +33.557.97.17.97
ATEX atmosphere secured groundingEliminating electrostatic chargesfrom mobile containers
Grounding plug with or without safety automation
Mobile and self-powered version MATIS-SDE4-NOMAD
1 channel or 2 channels versionsSeparate power supply MATIS-SDE4-ALIB
Safety automa�on op�on MATIS-SDE4-NOMADAUTO
15 m winder op�on MP3...EX / MP4...EX
MATIS-6F22 Power supply sourceop�on for MATIS-NOMAD
Tanker / Truck
Wagon
Mixer / Filling machine
Drum barrel
Hard and flexible intermediate bulk container
Uses MATIS range
A puissance 3 company - ATEX manufacturer since 1983 - http://apuissance3.com/eng - +33.5.57.97.17.97
Ex ia sensor / transmitter connection with anIntrinsic safety interface
Temperature
Pressure
Flowmeter
Level
Analyse
XT2 wires
Ex ia transmitter
Power & interface Ex ia sensor / transmitter in ATEX atmosphere
Intrinsic Safety (IS) analog interface type PROFSI3
- IS sensor power-in- Ex ia sensor protection- 4-20 mA analog measurement copy- HART protocol compliant- Galvanic isolation for the IS current loop- PLC pre-wired by modulo 8
HE10
Analog sensor
Connection between ATEX Ex ia proximity switches,ATEX Ex ia solenoid valve and ATEX interface
Ex ia inductif feedback
Ex ia solenoid valve
Regulate a pneumatic valve in ATEX zone with a IS solenoid valve and IS inductive NAMUR proximity switches
Intrisic Safety (IS) digital interface type NAEV30
- Compatible with all type of NAMUR Ex ia proximity switch- Compatible with most of Ex ia solenoid valve- 2 or 4 dry contact or IS NAMUR inductif input- 2 or 4 IS load driver output- PLC pre-wired by modulo 4,8,16 or 32 channels- Easy wiring and commissioning
HE10
NAEV30
ON / OFF Valve control
Drive a continuous control valve witha ATEX ia Hart positioner
2 wires 4-20 mA
2 wires 4-20 mA
Hart Ex iapositioner
PROFSI2-25082-AWP-NSH
Control an ATEX Ex ia Hart positioner on a continuous controlvalve in ATEX atmosphere
Intrinsic safety analog interface type PROFSI2-NSH- Intrinsic safety power supply for the positioner- 13 Volts power supply over 20 mA- 650 ohm max. load- Hart positioner compatible- Galvanic isolation of the driving signal- Full guaranteed interoperability with the positioner
IS
None ISMade in France
Continuous control valve
Designed for ATEX 2014/34/EU directive compliance.All ATEX electric motors must be thermally protected
Mechanical threshold
ATEX bimetallic +
ATEX digital interface
ATEX zone 1 certified
Switching threshold at 120°CHysteresis of 30°C
Aluminium body
Screw fixing M6 x 8 mm
cost-effective
digital threshold
ATEX RTD100 probe witha pod attachment +
ATEX digital thermostat
ATEX zone 1 certified
USB threshold setting
Factory threshold setting : 120°C
Global accuracy 5°C
Brass body
Total MTBF : 90 Years
Thermal protection for ATEX electric motor
Application overview for ATEX atmosphere
PROFSI3
Industrial process applications examples
A puissance 3 companyZA Les Pins Verts - 1 allée de Migelane F-33650 SAUCATS - FRANCE
Tél : +33 (0)5 57 97 17 97 - e-mail: [email protected] - www.apuissance3.com/eng
ATEX IS Pure water flow metering
Paddle-wheel flow sensorFor ATEX zone 1Pipe diameters from 1/4" to 2 1/2"ASME/DIN/ISO/SMSWeld ends connection
Flow transmitterATEX zone 12 wires 4-20 mA outputBluetooth 5.0 setting
ATEX analog interfaceLoop power supplyGalvanic isolation4-20 mA active feeback
rev 01 - Feb 2020 - Subject to altera�ons